1 Uponor Infra Fintherm a.s. Pre-insulated pipes and accessories catalogue

2

3 Introduction Standard pre-insulated pipes offered in this catalogue are primarily used for heating or cooling distribution systems including the following applications: low temperature hot water heating, medium temperature hot water heating, high temperature hot water heating, primary hot water service, chilled water, condensate and others. However, other applications with specific materials are available upon request. Wehotherm Standard is used for heat distribution. It meets the requirements of European Association standards (including the German Association AGFW / FW401 and EUROHEAT & POWER), and the harmonised European standards EN 253, EN 448, EN 488, and EN 489 as amended. These pre-insulated pipes are manufactured from steel pipes insulated with hard polyurethane foam covered with a layer of polyethylene. The standard series is intended for a maximum working overpressure of 2,5 MPa and a maximum working temperature of 142 C (150 C on a short-term operating basis) with a service life of 30 years. In addition, we can offer pipes with increased thermal resistance of up to 165 C, also with a 30-year service life. Wehotek Spiro is used for above-ground heat distribution. These pre-insulated pipes are manufactured from steel pipes insulated with hard polyurethane foam, and covered with spiral overlaid steel zinc-coated sheets. The pipes are intended for a maximum working overpressure of 2,5 MPa and a maximum working temperature of 142 C (150 C on a short-term operating basis) with a 30-year service life. In addition, we can offer pipes with increased thermal resistance of up to 165 C, also with a 30-year service life. Wehotherm Twins is used for heat distribution. These pre-insulated pipes are manufactured from steel pipes insulated with hard polyurethane foam covered with a layer of polyethylene. The insulation is applied to the supply and return pipes, forming a pair. The pipes are manufactured in compliance with EN The standard series is intended for a maximum working overpressure of 2,5 MPa, a maximum working temperature of 130 C, and a maximum temperature difference of 50 C between the supply and return pipes, with a 30-year service life. Wehotek PPR is used for hot water distribution designated as HSW - Hot Service Water. These pre-insulated pipes are manufactured from polypropylene PP-R pipes, insulated with hard polyurethane foam covered with a layer of polyethylene. This pipe system is designed for a maximum working overpressure of 1 MPa and a maximum working temperature of 70 C, with a 25-year service life. Pipe systems for other applications In addition to the above standard systems, we manufacture pre-insulated pipes which can be produced in other materials according to customer requirements. Uponor Infra Fintherm has extensive experience with the insulation of pipes for the chemical and refrigeration industries, water supply utilities, sanitation, and others. The long-term operating temperature range using polyurethane insulation is between -196 C and +142 C, and with up to 150 C for short-term operation. For higher operating temperatures of up to 165 C, we offer pipes with special polyurethane foam insulation, capable of handling higher temperatures. For media-carrying pipes, we can manufacture systems in steel, stainless steel, acid resistant material, galvanised steel, copper, polyethylene, polybutene, polypropylene, glass fibre, PEX, cast iron, and other material with polyethylene or metal spiral overlaid sheet depending on the specific application. Wehotherm pipe systems are produced with Nordic system sensor wires as a standard, in compliance with EN Pipes with other types of sensor wires (e.g., Brandes, Hagenuk, and Isotronic) can be supplied upon request. Uponor Infra Fintherm reserves the right to make changes without prior notice. 1 / 2015 For the latest technical information see our websites 3

4 4

5 1 Wehotherm Standard 2 Wehotek Spiro Casing 3 Wehotherm Twins 4 Wehotek PPR 5 Pipe systems for different applications 6 Accessories 7 Quality and Certifications 5

6 6

7 Wehotherm Standard 1 Wehotherm Standard Steel carrier pipes Pipes Bends Elbows T-branches Reducers Anchors Elbow anchors One time compensators Shut-off valves Drain/Air relief valves Combination valves 7

8 Wehotherm Standard Wehotherm Standard Steel carrier pipe The steel piping used in the Wehotherm system is made of longitudinally or helically welded pipes in compliance with the EN , EN , and EN standards or, upon request, seamless pipes in accordance with EN Unless otherwise stated, the values in this catalogue apply to welded pipes in compliance with the EN10217 standard. Material: P 235 GH, P 235 TR 1, P 265 GH Certification: EN Bevelling: DIN 2559/22, ISO 6761 engths: DN 20, DN 25: = 6 m DN 32 - DN 80: = 6 m, 12 m DN DN 700: = 6 m, 12 m, 16 m Density: 7850 kg/m 3 Modulus of elasticity: 2, N/mm 2 Yield strength: 235 N/mm 2 Tensile strength: 350 N/mm 2 Heat conductivity: 46-54,5 W/mK Thermal expansion coefficient: 1, K Rigid PUR insulation Rigid polyurethane foam (PUR) is produced by mixing polyalcohols (polyols) containing additives and isocyanates (MDI). The mixture is injected into pipes using a high-pressure foaming technique. Cyclopentane is used as the foaming agent. The PUR foam used in the Wehoterm Standard system is CFC-free and meets the stringent requirements of European Standard EN 253. Average cell size: 0,5 mm Closed cell content: 88 % Core density: 60 kg/m 3 Compressive strength: 0,3 MPa Water absorption: 0,12 MPa Thermal conductivity (+ 50 C): 0,026 W/mK PE-HD casing pipe Material PE-HD (high-density polyethylene) Dimensions: EN 253 Material: PE-HD Density (+20 C): ~ 960 kg/m 3 Heat conductivity: 0,43W/mK Thermal expansion coefficient: 1, K -1 Melt flow index (MFI 190/5): 0,2 to 1,4 Carbon black content: 2,5 ± 0,5 % ASTM D Elongation at break: 350% ISO R-292 Impact strength: 10 mj/mm 2 ISO R-179 Tensile strength: 17 MPa ISO DIS 572B The material is protected against the effects of UV radiation For the latest technical information see our websites 1 / 2015

9 Wehotherm Standard Pipes Wehotherm Standard l 004bl D d s Insulation class 1 DN d. s D Pipes can be manufactured in other lengths, dimensions, and insulation thicknesses upon request. engths of the non-insulated pipe end: DN 350 l =170 ± 10 mm DN 400 l =190 ± 10 mm (m) Weight (kg/m) Insulation thickness Water volume (l/m) 20 26,9. 2, ,8 29 0, ,7. 2, ,2 25 0, ,4. 2, , 12 4,1 31 1, ,3. 2, , 12 4,5 28 1, ,3. 2, , 12 5,9 29 2, ,1. 2, , 12 7,3 29 3, ,9. 3, , 12 9,1 33 5, ,3. 3, , 12, 16 13,2 40 9, ,7. 3, , 12, 16 16, , ,3. 4, , 12, 16 20, , ,1. 4, , 12, 16 30, , ,0. 5, , 12, 16 43, , ,9. 5, , 12, 16 56, , ,6. 5, , 12, 16 64, , ,4. 6, , 12, 16 81, , ,0. 6, , 12, 16 87, , ,0. 6, , 12, 16 99, , ,0. 8, , 12, , , ,0. 8, , 12, , , to 1200 upon request Code: WTS (insulation class) P (DN/casing diameter) (length) Ex.: WTS 1 P DN100/200 12m 1 / 2015 For the latest technical information see our websites 9

10 Wehotherm Standard Wehotherm Standard Pipes l 004bl D d s Insulation class 2 DN d. s D Pipes can be manufactured in other lengths, dimensions, and insulation thicknesses upon request. engths of the non-insulated pipe end: DN 350 l =170 ± 10 mm DN 400 l =190 ± 10 mm (m) Code: WTS (insulation class) P (DN/casing diameter) (length) Ex.: WTS 2 P DN100/225 12m Weigh (kg/m) Insulation thickness Water volume (l/m) 20 26,9. 2, ,2 39 0, ,7. 2, , 12 3,6 35 0, ,4. 2, , 12 4,5 38 1, ,3. 2, , 12 4,8 35 1, ,3. 2, , 12 6,3 37 2, ,1. 2, , 12 7,8 39 3, ,9. 3, , 12 9,7 43 5, ,3. 3, , 12, 16 14,1 52 9, ,7. 3, , 12, 16 17, , ,3. 4, , 12, 16 22, , ,1. 4, , 12, 16 32, , ,0. 5, , 12, 16 47, , ,9. 5, , 12, 16 61, , ,6. 5, , 12, 16 70, , ,4. 6, , 12, 16 89, , ,0. 6, , 12, 16 94, , ,0. 6, , 12, , , ,0. 8, , 12, , , ,0. 8, , 12, , , to 1200 upon request 10 For the latest technical information see our websites 1 / 2015

11 Wehotherm Standard Pipes Wehotherm Standard l 004bl D d s Insulation class 3 DN d. s D Pipes can be manufactured in other lengths, dimensions, and insulation thicknesses upon request. engths of the non-insulated pipe end: DN 350 l =170 ± 10 mm DN 400 l =190 ± 10 mm (m) Weight (kg/m) Insulation thickness Water volume (l/m) 20 26,9. 2, ,5 46 0, ,7. 2, , 12 4,0 43 0, ,4. 2, , 12 4,9 46 1, ,3. 2, , 12 5,2 43 1, ,3. 2, , 12 6,9 47 2, ,1. 2, , 12 8,5 49 3, ,9. 3, , 12 10,4 52 5, ,3. 3, , 12, 16 15,2 64 9, ,7. 3, , 12, 16 18, , ,3. 4, , 12, 16 23, , ,1. 4, , 12, 16 35, , ,0. 5, , 12, 16 51, , ,9. 5, , 12, 16 67, , ,6. 5, , 12, 16 77, , ,4. 6, , 12, 16 94, , ,0. 6, , 12, , , ,0. 6, , 12, , , ,0. 8, , 12, , , to 1200 upon request Code: WTS (insulation class) P (DN/casing diameter) (length) Ex.: WTS 3 P DN100/250 12m 1 / 2015 For the latest technical information see our websites 11

12 Wehotherm Standard Wehotherm Standard Bends 005a Straight ends of bends are approx. 2.5 m long (dimension as above drawing). Bends are produced on special forming equipment and are based on an advance customer order which specifies the required angle. The benchmark for determining the specific angle α is the angle measured at the central axis of the trench, taking into account the length of the straight ends. The standard straight pipes can be formed on site up to dimension DN 100 and bending angle up to 15. DN Maximum bending angle α The values given are for 12 m pipes. Important note: We recommend that trench space is suitable for the specific shape of the bends with straight ends delivered. Code: WTS (insulation class) PB (DN/casing diameter) (length) Ex.: WTS 2 PB DN100/ m For the latest technical information see our websites 1 / 2015

13 Wehotherm Standard Elbows Wehotherm Standard 006bl bl Wehotherm Standard prefabricated insulated elbows are manufactured in the following standard angles: 45 and 90. Other angles, curve radii, and manufacturing dimensions can be supplied upon special request. Casing segments are butt-welded. Bending Radius R: Elbow bent - DN 20 - DN 100: R = 3 D - DN DN 500: R = 2,5 D (upon request) Elbow welded - DN DN 600: R = 1,5 D DN Elbow bent Elbow welded R R R R D D D D D D D D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D ,5 D 600 to 1200 upon request We can supply bending radii other than those listed upon request. Code: WTS (insulation class) E (DN/casing diameter) (angle) Ex.: WTS 1 E DN40/ / 2015 For the latest technical information see our websites 13

14 Wehotherm Standard Wehotherm Standard Building entry elbows DN 20 - DN bl bl 2000 The DN 20 - DN 250 elbows are designed to be installed through the floor of the building being connected to the system. If larger dimensions are required, they will be dealt with on an individual basis. Code: WTS (insulation class) E (DN/casing diameter) ( = longer dimension of the arm x shorter dimension of the arm) Ex.: WTS 1 E DN50/125 = 2,0x1,5m 14 For the latest technical information see our websites 1 / 2015

15 Wehotherm Standard T-branches The following are used to branch off the main pipe: 012a Wehotherm Standard Parallel branch Elevated branch Straight branch Implementation of the steel T-branch from the main route: 1) Necked-Out (Collaring) T-branch Standard T-piece Standard design using the cold-forming method for the neck and the V weld. An advantage of this design is the higher overall strength of the V weld compared to a fillet weld, and better shape for the flow of the medium. 2) Forged T-piece For a branch of the same dimension as that of the main line, welded-on forged T-pieces are to be used in accordance with EN , with the same wall thickness of the main line branch base and the branch. 3) Welded tube fitting In exceptional cases, when it is not technologically possible to use another construction method for the branch, branching with a fillet weld is used. Construction with reinforcement is also possible. 015 In the case of higher strength requirements for the branches, it is possible to supply T-branches with thicker walls; we recommend consulting Uponor Infra Fintherm technical department concerning the wall thickness, or determining such requirement based on static strength calculations according to the specific conditions of the project. 1 / 2015 For the latest technical information see our websites 15

16 Wehotherm Standard Wehotherm Standard Parallel T-branches 2 D 1 H H 1 016b D 2 H 1 = (D 1 + D 2 ) / 2 + H D 1, D 2 - diameter of the casing of the main pipe and the branch piece 1 H - distance between the surfaces of the casing pipes Arm lengths and distance between the surfaces of the casing pipes according to the dimensions of the branch piece: DN DN 2 50: 1 = 1000 mm, 2 = 1000 mm, H = 120 mm DN DN 2 100: 1 = 1000 mm, 2 = 1000 mm, H = 200 mm DN DN 2 200: 1 = 1200 mm, 2 = 1000 mm, H = 200 mm DN DN 2 300: 1 = 1500 mm, 2 = 1000 mm, H = 300 mm arger sizes and lengths different to 1 and 2 are available upon request. Example of the location of expansion pads: Expansion pad Expansion pad 017en To allow movement in the axial direction of the branch, expansion foam pads are inserted on both sides of the branch. The length is designed according to the movement of the branch and possible compression of the expansion pads upon the thermal expansion of the pipe. Code: WTS P-T (insulation Class-DN of the main route/casing diameter) x (insulation Class-DN of the branch/casing diameter) Ex.: WTS P-T 1-DN100/200 x 1-DN65/ For the latest technical information see our websites 1 / 2015

17 Wehotherm Standard Elevated T-branches Wehotherm Standard 2 H 1 H D D1 H 1 = (D 1 + D 2 ) / 2 + H (see table) D 1, D 2 - diameter of the casing of the main pipe and the branch piece 012 H = 35 mm distance between the surfaces of the casing pipes Arm lengths according to the dimensions of the branch piece: DN DN 2 100: 1 = 1000 mm 2 = 1000 mm DN DN 2 200: 1 = 1200 mm 2 = 1000 mm DN DN 2 300: 1 = 1500 mm 2 = 1000 mm arger sizes and lengths different to 1 and 2 are available upon request. The table indicates the distance H 1 between the axis of the main pipe and the branch piece for insulation class 1: DN 2 DN Code: WTS E-T (insulation Class-DN of the main route/casing diameter) x (insulation Class-DN of the branch/casing diameter) Ex.: WTS E-T 1-DN80/160 x 1-DN65/140 1 / 2015 For the latest technical information see our websites 17

18 Wehotherm Standard Wehotherm Standard Methods of implementation of the elevation branch from the main route are: 1) use of the T-elevation branch, T straight branch, (branched pipe returns to the same height as that of the main pipe after crossing the adjacent pipe) 2) use of two T-elevation branches (branched pipe is at a different height than the main pipe) 1) 2) Recoils 067b 067c 45 V Dimensions of recoils: This is a custom-made product with recoil heights and lengths set according to production capability; we encourage you therefore to consult with Uponor Infra Fintherm technical department regarding the required values. WTS J (insulation Class-DN of the main pipe/casing diameter) (V=recoil height) (=recoil length) WTS J 1-DN65/140 V=205 mm =1500 mm Straight T-branch DN 2 engths of the main pipe according to the dimensions of the branch piece: DN DN 2 100: 1 = 1000 mm DN DN 2 200: 1 = 1200 mm DN DN 2 300: 1 = 1500 mm 1000 arger sizes and lengths are available upon request. 012b 1 Code: WTS S-T (insulation Class-DN of the main route/casing diameter) x (insulation Class-DN of the branch/casing diameter) Ex.: WTS S-T 1-DN80/160 x 1-DN65/ For the latest technical information see our websites 1 / 2015

19 Wehotherm Standard Reducers Prefabricated reducers Wehotherm Standard D D Pre-insulated reducers can be supplied in the following casing pipe sizes: D 1 D For other sizes, different technical solutions are offered. Important note: For hydraulic and strength reasons, we recommend using reducers with a diameter change of no more than two of DN degrees. If a larger DN change is necessary, use more reducers arranged in succession in accordance with the design documentation. When ordering, please specify the DN dimensions and insulation class. Code: WTS RED (insulation class - larger DN/casing diameter) x (insulation class - smaller DN/casing diameter) Ex.: WTS RED 1-DN100/200 x 1-DN80/160 1 / 2015 For the latest technical information see our websites 19

20 Wehotherm Standard Wehotherm Standard Modular reduction kits (reduced joints) Wehotherm Standard reduction kits (for installation in joints) are offered as standard shrinkable version. The advantage of the shrinkable modular reduction kit is that there are two independent systems for sealing a reduced joint. The kit comprises: 1. PE shrinkable casing reducer 1 piece 2. Steel reducer 1 piece 3. Narrow shrink sleeve 2 pieces 4. Closing patch 2 pieces 5. Venting plug 2 pieces 6. Welding plug 2 pieces 7. Electrical wire support 2 pieces 8. Electrical wire connector 2 pieces 9. Sealing tape 1 piece - PUR components (quantity according to the size) b The PE casing reducer is placed over the smaller casing pipe prior to welding of the steel reducer. 020 The subsequent installation procedure of the shrinkable modular reduction kit is similar to the installation procedure for the DSJ double-sealed shrinkable joint. Important note: For hydraulic and strength reasons, we recommend using reducers with a diameter change of no more than two of DN degrees. If a larger DN change is necessary, use more reducers arranged in succession in accordance with the design documentation. Code: WTS DSJ-SRK (PE larger casing diameter/smaller casing diameter) Steel reducer (larger DN/smaller DN) Ex.: WTS DSJ-SRK PE160/140 Steel reducer DN80/DN65 20 For the latest technical information see our websites 1 / 2015

21 Wehotherm Standard Anchors Wehotherm Standard s 021bl 50 DN (m) Wehotherm Standard anchors are designed to be embedded into a reinforced concrete block. It may also be attached to the supporting structure (e.g. welded to a steel structure). S = area of anchor plate outside the casing s = anchor plate thickness s Code: WTS (insulation class) AP (DN/casing diameter) Ex.: WTS 1 AP DN80/160 Insulation class 1 Insulation class 2 Insulation class 3 S (cm 2 ) S (cm 2 ) S (cm 2 ) / 2015 For the latest technical information see our websites 21

22 Wehotherm Standard Wehotherm Standard Elbow anchors 022bl DN R Wehotherm Standard elbow anchors are manufactured with both arms of equal length. The dimensions of the anchor plates are similar to those of the anchors (see Chapter 1.2.6). Bending Radius R: DN 20 - DN 100: R = 3 D DN DN 600: R = 1,5 D Code: WTS (insulation class) EA (DN/casing diameter) (elbow angle) Ex.: WTS 1 EA DN65/ For the latest technical information see our websites 1 / 2015

23 Wehotherm Standard One time compensators Expansion D k Wehotherm Standard 024en One time compensators are used to reach the desired values of pipe prestressing and maintaining it at a stable value. Backfilling can be done prior to pre-heating of the pipe; only expansion joints are left unsealed. If the depth of the cover over the pipe changes by more than 25%, the expansion of the pipe is enabled in a section with deeper installation by using plastic foil around the pipe casing. We recommend consulting the technical department of Uponor Infra Fintherm about the installation. DN Expansion PN 25 D k , , , , , , , , , , , , , , ,0 Important note: The compensator s position is stabilized with welds during transport. For pressure testing, the compensator must be secured against expansion with weld joints. When the pipe joint is foamed, the temperature must be in the range of 10 to 40 C. Before the compensator is installed, it is necessary to push the joint on the compensators. The one time compensator is installed in the joint at its full length. Preheating, the contraction of the compensator must reach the calculated thermal expansion of the piping. The joint is blocked in the compressed position by welding the compensator. 025 The compensator is covered by the compensator joint, which must be ordered separately, and the specific joint type must be determined by the customer. Technical data: - Material: AISI 321 / W-Nr Nominal pressure: 2,5 MPa Code: WTS OB (dimension) (nominal pressure) Exp (expansion) Ex.: WTS 1 OB DN100 PN 25 Exp 80 1 / 2015 For the latest technical information see our websites 23

24 Wehotherm Standard Wehotherm Standard Shut-off valves T-key Manual moment multiplier 026bl hmax 1500 Based on the customer s requirements, valves are controlled either manually with a T-key (for dimensions of DN20 to 150), through a manual moment multiplier, or with a gearbox (for dimensions of DN 200 and above). DN h max [mm] to 600 upon request Wehotherm shut-off valves DN 20 - DN 600 are manufactured only as a long spindle ball valves. Valve Material: - Valve body: carbon steel P235 GH - Ball: SIS 2333, AISI 304 (stainless steel) - Gasket: PTFE, carbon reinforced - Upper part of spindle: SIS 2333, AISI304 - stainless steel Code: WTS (insulating class) SV (piping DN/casing diameter) (rated pressure) Ex.: WTS 1 SV DN200/315 PN25 h max = maximum length from axis of carrier pipe to the upper end of spindle Important note: When the shut-off valve is being welded into the pipeline, the valve must be in the open position so as not to damage its seal. Shut-off valves can be supplied in various sizes and designs according to the customer s requirements. 029bl 24 For the latest technical information see our websites 1 / 2015

25 Wehotherm Standard Drain/Air relief valves Suction modification Wehotherm Standard Installation alternatives h Air relief D Drain (by suction) 030a 1000 s 1 min 031en Drain (by gravity) The drain and air relief parts of the valves are produced with an increased wall thickness compared to the thickness of standard pipes. Valve Material: - Service pipe: carbon steel P235 GH - Ball: SIS 2333, AISI 304 (stainless steel) - Gasket: PTFE, carbon reinforced A drain valve with a different height of the bleeding or discharge arm or a drain valve of a bigger size, height arm length can be supplied upon request. Code: WTS (insulation class) D/A-V (DN pipe dimension/casing diameter)/(dn valve dimension) Ex.: WTS 1 D/A-V DN100/200 x DN25 D = valve casing diameter s 1 = pipe wall thickness DN D s 1 min h , , , , , Gravitation model The drain and air relief parts of the valves are produced with an increased wall thickness compared to the thickness of standard pipes. 032a D s 1 min 032b The dimensions correspond to the elevated T-branch ( ) with a welded on shut-off valve. Valve Material: - Service pipe: carbon steel P 235 GH - Ball: SIS 2333, AISI 304 (stainless steel) - Gasket: PTFE, reinforced with carbon A drain valve with a different length of the bleeding or discharge arm or a drain valve of a bigger size can be supplied upon request. D = valve casing diameter s 1 = pipe wall thickness DN D s 1 min , , , , ,6 Code: WTS (insulation class) D-V (DN pipe dimension/casing diameter)/(dn air/drain valve dimension) Ex.: WTS 1 D-V DN200/315 x DN32 5 / 2015 For the latest technical information see our websites 25

26 Wehotherm Standard Wehotherm Standard Drain / Air relief valve - kits D h 033i s 1 min 1 The kit comprises: 1. Valve 1 piece 2. Saddle 1 piece 3. Narrow shrinks sleeves 2+1 pieces 4. Closing patches 2+1 pieces 5. Venting plugs 2 pieces 6. Welding plugs 2 pieces 7. Centring ring 1 piece - PUR components (quantity according to the dimensions) DN D s 1 min h , , , , ,6 500 D = valve casing diameter s 1 = pipe wall thickness The drain / air relief valve kit is designed for on-site assembly. The drain and air relief parts of the valves are produced with an increased wall thickness compared to the thickness of standard pipes. Drain valves with a different wall-thickness, larger diameter, or different air relief or drain arm length can be supplied upon request. For installation, see 6.7. Valve Material: - Service pipe: carbon steel P235 GH - Ball: SIS 2333, AISI stainless steel - Gasket: PTFE, carbon reinforced Code: WTS (insulation class) D/A-V KIT (DN pipe dimension/casing diameter) / (DN air/drain valve dimension) Ex.: WTS 1 D/A-V KIT DN80/160 x DN Service welded valve s 1 min An air relief valve or drain valve welded on a pipe separately is available upon request. For dimensions and materials see Chapter i D Code: WTS (insulation class) D/A-S (DN pipe dimension)/(casing diameter) (= length) Ex.: WTS 1 D/A-S DN50/125 =500 mm 26 For the latest technical information see our websites 5 / 2015

27 Wehotherm Standard Combination valves Wehotherm Standard Single-sided combination valve Double-sided combination valve Wehotherm Standard combination valves are produced as ball valves with either single-sided or double-sided drain / air relief valves. DN closing valve h max to 600 upon request Combined drain / air relief valves in the DN 20 to 50 range are standard. The drain and air relief parts of the valves are produced with an increased wall thickness compared to the thickness of standard pipes, for dimension and materials see Chapter Valve Material: - Valve body: carbon steel P235 GH - Ball: SIS 2333, AISI stainless steel - Gasket: PTFE, carbon reinforced - Upper part of spindle: SIS 2333, AISI stainless steel Important note: When the combined valve is being welded into the pipeline, the valve must be in the open position so as not to damage its seal. 035 h max h max Air relief/shut-off/air relief Drain/Shut-off/Air relief Drain/Shut-off/Drain Code: WTS (insulation class) COMBI V (DN shut-off valve dimension/casing diameter) x (one-sided: DN drain / air relief valve dimension) Ex.: WTS 1 COMBI V DN100/200 x DN32 or WTS (insulation class) COMBI V (DN shut-off valve dimension/casing diameter) 2x (double-sided: DN drain / air relief valve dimensions, DN drain / air relief valve dimensions) Ex.: WTS 1 COMBI V DN80/160 2x DN32 1 / 2015 For the latest technical information see our websites 27

28 28

29 2 Wehotek Spiro Steel carrier pipe Rigid polyurethane insulation Spiro casing pipe Pipes Elbows Spiro joints Other pre-insulated components with Spiro casing Wehotek Spiro Casing 1 / 2015 For the latest technical information see our websites 29

30 Wehotek Spiro Steel carrier pipe Wehotek Spiro Casing The steel piping used in the Wehotek Spiro Casing system is made of longitudinally or helically welded pipes in compliance with the EN , EN , and EN standards or, upon request, of seamless pipes in accordance with EN Material: P 235 GH, P 235 TR 1, P 265 GH Certification: EN Bevelling: DIN 2559/22 engths: DN 20, DN 25: = 6 m DN 32 - DN 80: = 6 m, 12 m DN DN 700: = 6 m, 12 m, 16 m Density: 7850 kg/m 3 Modulus of elasticity: 2, N/mm 2 Yield strength: 235 N/mm 2 Tensile strength: 350 N/mm 2 Heat conductivity: 46-54,5 W/mK Thermal expansion coefficient: 1, K Rigid PUR insulation Rigid polyurethane foam (PUR) is produced by mixing polyalcohols (polyols) containing additives and isocyanates (MDI). The mixture is injected into pipes using a high-pressure foaming technique. Cyclopentane is used as the foaming agent. The PUR foam used in the Wehotek Spiro Casing system is CFC-free and meets the stringent requirements of European Standard EN 253. Average cell size: 0,5 mm Closed cell content: 88 % Core density: 60 kg/m 3 Compressive strength: 0,3 MPa Water absorption: 10 % Shear strength: 0,12 MPa Thermal conductivity (+ 50 C): 0,026 W/mK Spiro casing pipe Spiro casing pipes are made of spiral overlaid steel zinc-coated sheets. Other material is available upon request wts For the latest technical information see our websites 1 / 2015

31 Wehotek Spiro Pipes wts00006 D 039bl s l = 170 ± 10 mm d Wehotek Spiro Casing Insulation class 1 DN d. s D (m) Weight (kg/m) A standard casing pipe is made of spiral overlaid steel zinc-coated sheets. Pipes are available in other sizes upon special request. Insulation thickness Water volume (l/m) 20 26,9. 2, ,0 26 0, ,7. 2, ,4 23 0, ,4. 2, , 12 4,8 32 1, ,3. 2, , 12 5,2 30 1, ,3. 2, , 12 6,9 32 2, ,1. 2, , 12 8,4 31 3, ,9. 3, , 12 10,5 35 5, ,3. 3, , 12, 16 14,8 42 9, ,7. 3, , 12, 16 17, , ,3. 4, , 12, 16 22, , ,1. 4, , 12, 16 31, , ,0. 5, , 12, 16 47, , ,9. 5, , 12, 16 59, , ,6. 5, , 12, 16 66, , ,4. 6, , 12, 16 83, , ,0. 6, , 12, 16 88, , ,0. 6, , 12, , , ,0. 8, , 12, , , ,0. 8, , 12, , ,60 Code: WT (insulation class) P (DN/casing diameter) Spiro (length) Ex.: WT 1 P DN100/200 Spiro 12m 1 / 2015 For the latest technical information see our websites 31

32 Wehotek Spiro Pipes Wehotek Spiro Casing 039bl D s l = 170 ± 10 mm d Insulation class 2 DN d. s D (m) Weight (kg/m) A standard casing pipe is made of spiral overlaid steel zinc-coated sheets. Pipes are available in other sizes upon special request. Insulation thickness Water volume (l/m) 20 26,9. 2, ,9 41 0, ,7. 2, ,3 38 0, ,4. 2, , 12 5,4 41 1, ,3. 2, , 12 5,8 38 1, ,3. 2, , 12 7,3 39 2, ,1. 2, , 12 9,0 41 3, ,9. 3, , 12 11,2 45 5, ,3. 3, , 12, 16 15,8 55 9, ,7. 3, , 12, 16 18, , ,3. 4, , 12, 16 23, , ,1. 4, , 12, 16 33, , ,0. 5, , 12, 16 50, , ,9. 5, , 12, 16 63, , ,6. 5, , 12, 16 72, , ,4. 6, , 12, 16 93, , ,0. 6, , 12, 16 98, , ,0. 6, , 12, , , ,0. 8, , , , ,0. 8, , , ,62 Code: WT (insulation class) P (DN/casing diameter) Spiro (length) Ex.: WT 2 P DN100/225 Spiro 12m 32 For the latest technical information see our websites 1 / 2015

33 Wehotek Spiro Pipes 039bl D s l = 170 ± 10 mm d Wehotek Spiro Casing Insulation class 3 DN d. s D (m) Weight (kg/m) A standard casing pipe is made of spiral overlaid steel zinc-coated sheets. Pipes are available in other sizes upon special request. Insulation thickness Water volume (l/m) 20 26,9. 2, ,5 48 0, ,7. 2, ,9 45 0, ,4. 2, , 12 5,9 48 1, ,3. 2, , 12 6,2 45 1, ,3. 2, , 12 8,0 49 2, ,1. 2, , 12 9,7 51 3, ,9. 3, , 12 12,0 55 5, ,3. 3, , 12, 16 16,9 67 9, ,7. 3, , 12, 16 20, , ,3. 4, , 12, 16 25, , ,1. 4, , 12, 16 39, , ,0. 5, , 12, 16 54, , ,9. 5, , 12, 16 68, , ,6. 5, , 12 82, , ,4. 6, , , , ,0. 6, , , , ,0. 6, , , , ,0. 8, , , ,74 Code: WT (insulation class) P (DN/casing diameter) Spiro (length) Ex.: WT 3 P DN100/250 Spiro 12m 1 / 2015 For the latest technical information see our websites 33

34 Wehotek Spiro Wehotek Spiro Casing Elbows Prefabricated elbows 040bl Prefabricated insulated elbows are made in standard 45 and 90 angles. For other sizes, insulation class, specific angle or bending radius R, please contact the Uponor Infra Fintherm technical department. engths of the non-insulated pipe ends for small sizes of up to DN 50 are shorter than the lengths of straight pipes. Code: WT (insulation class) E (DN/casing diameter) (angle) Spiro Ex.: WT Spiro 1 E DN40/ Spiro The table shows the dimensions for a 90 angle in the first and second insulation classes. DN R Insulation class 1 Insulation class Spiro joints The kit contains: 1. Coiled casing metal plate 1 piece 2. Sealing tape 1 piece 3. Rivets 9 pieces 4. Covering metal patch 1 piece - PUR components (quantity according to the dimensions) Standard length of Spiro joints is 500 mm. The covering metal patch is installed by four rivets Code: WT Spiro connection pipe (DN pipe dimension / casing diameter) Ex.: WT Spiro joint DN200/ Other pre-insulated components with Spiro casing We can supply pre-insulated valves, branches, reducers, and other fittings covered with Spiro casing upon request. Basic information about the Wehotherm Standard system can be used, while the actual dimensions and manufacturing options must be discussed in advance with the Uponor Infra Fintherm technical department. 34 For the latest technical information see our websites 1 / 2015

35 3 Wehotherm Twins Steel carrier pipe Rigid polyurethane insulation PE-HD Casing pipe Pipes Elbows Building entry elbows T-branches Change-pieces Anchors Elbow anchors Shut-off valves Drain/Air relief valves Wehotherm Twins 35

36 Wehotherm Twins Steel carrier pipe The steel piping used in the Wehotherm Twins system is made of longitudinally or helically welded pipes in compliance with EN , EN , and EN standards or, upon request, of seamless pipes in accordance with EN Material: P 235 GH, P 235 TR 1, P 265 GH Certification: EN Bevelling: DIN 2559/22, ISO 6761 engths: DN 20, DN 25: = 6 m DN 32 - DN 80: = 6 m, 12 m DN DN 250: = 6 m, 12 m, 16 m Wehotherm Twins Density: 7850 kg/m 3 Modulus of elasticity: 2, N/mm 2 Yield strength: 235 N/mm 2 Tensile strength: 350 N/mm 2 Heat conductivity: 46-54,5 W/mK Thermal expansion coefficient: 1, K Rigid PUR insulation 036 Rigid polyurethane foam (PUR) is produced by mixing polyalcohols (polyols) containing additives and isocyanates (MDI). The mixture is injected into pipes using a high-pressure foaming technique. Cyclopentane is used as the foaming agent. The PUR foam used in the Wehoterm Twins system is CFC-free and meets the stringent requirements of European Standard EN 253. Average cell size: 0,5 mm Closed cell content: 88 % Core density: 60 kg/m 3 Compressive strength: 0,3 MPa Water absorption: 10 % Shear strength: 0,12 MPa Thermal conductivity (+ 50 C): 0,026 W/mK PE-HD casing pipe Material PE-HD (high-density polyethylene) Dimensions: EN 253 Material: PE-HD Density (+20 C): ~ 960 kg/m 3 Heat conductivity: 0,43W/mK Thermal expansion coefficient: 1, K -1 Melt flow index (MFI 190/5): 0,2 to 1,4 Carbon black content: 2,5 ± 0,5 % ASTM D Elongation at break: 350% ISO R-292 Impact strength: 10 mj/mm 2 ISO R-179 Tensile strength: 17 MPa ISO DIS 572B The material is protected against the effects of UV radiation For the latest technical information see our websites 1 / 2015

37 Wehotherm Twins Pipes l = 170 ± 10 mm d D H 043bl s Insulation classes 1 and 2 DN d. s Insulation class 1 D Insulation class 2 (m) H Weight (kg/m) Insulation class 1 Insulation class 2 Wehotherm Twins ,9. 2, , ,0 5, ,7. 2, , ,2 6, ,4. 2, , ,7 8, ,3. 2, , ,4 9, ,3. 2, , ,9 13, ,1. 2, , ,9 16, ,9. 3, , ,7 20, ,3. 3, , ,5 30, ,7. 3, , 12, ,6 41, ,3. 4, , 12, ,4 54, ,1. 4, , 12, ,2 81, ,0. 5, , 12, ,4 123,1 Pipes can be manufactured in other lengths and dimensions upon special request. Code: 2WTS (insulation class) P (DN/casing diameter) (length) Ex.: 2WTS 1 P DN /140 12m 1 / 2015 For the latest technical information see our websites 37

38 Wehotherm Twins Elbows 1000 Vertical elbow (V) Horizontal elbow (H) Wehotherm Twins 044enbl 1000 Wehotherm Twins elbows are manufactured in standard angles of 45 and 90. Elbows with other angles or manufacturing dimensions can be supplied upon special request. The elbows are divided into horizontal and vertical types according to the pipe route deviation and standard pipe installation* in the trench: - a horizontal elbow is used when the route turns to the left or the right. - a vertical elbow is used where height difference in the route is encountered. * The Wehotherm Twins system standard trench installation consists of the supply pipe at the bottom and the return pipe at the top (one pipe above the other). Code: 2WTS (insulation class) E (DN/casing diameter) (H=horizontal or V=vertical elbow) (angle) Ex.: 2WTS 1 E DN65+65/225 H Building entry elbow DN 20 - DN 250 Building entry elbows are always produced as vertical. 045bl Code: 2WTS (insulation class) E (DN/casing diameter) (V=vertical) (=arm longer dimension x arm shorter dimension) Ex.: 2WTS 1 E DN65+65/225 =2,0x1,5m 38 For the latest technical information see our websites 1 / 2015

39 Wehotherm Twins T-branches b* 047bl Wehotherm Twins T-branches are manufactured in the following dimensions: DN 20 - DN 100: = 1000 mm b = 1000 mm DN DN 250: = 1200 mm b = 1000 mm * Dimension b is taken from the centre of the casing pipe of the main route. Code: 2WTS T (insulation class-dn main pipe dimension/casing diameter) X (insulation class- DN branch dimension/casing diameter) Ex.: 2 WTS T 1-DN80+80/250 x 1-DN32+32/160 Wehotherm Twins Implementation of the steel T-branch from the main route: 1) Necked-Out (Collaring) T-branch Standard T-piece Standard design using the cold-forming method for the neck and the V weld. An advantage of this design is the higher overall strength of the V weld compared to a fillet weld, and better shape for the flow of the medium. 2) Forged T-piece For a branch of the same dimension as that of the main line, welded-on forged T-pieces are to be used in accordance with EN , with the same wall thickness of the main line branch base and the branch. 3) Welded tube fitting In exceptional cases, when it is not technologically possible to use another construction method for the branch, branching with a fillet weld is used. Construction with reinforcement is also possible. 015 In the case of higher strength requirements for the branches, it is possible to supply T-branches with thicker walls; we recommend consulting Uponor Infra Fintherm technical department concerning the wall thickness, or determining such requirement based on static strength calculations according to the specific conditions of the project. 1 / 2015 For the latest technical information see our websites 39

40 Wehotherm Twins Change-pieces Change-pieces Y-model Change-pieces Y-model are used to transfer from a Wehotherm Standard system to a dual Wehotherm Standard Twins system or vice versa. DN C-C C-C Wehotherm Twins 049bn We can supply alternatives to the standard spacing (designated C-C) between the Wehotherm Standard pipes upon request. When ordering, please indicate the direction of the transfer according to the following diagram: RD = A 1 RU = A 2 A A Code: 2WTS CPY (insulation class-dn twin pipe/casing diameter) x (insulation class-dn/casing diameter) (direction of the transition) Ex.: 2 WTS CPY 1-DN40+40/160 x 1-DN40/110 RD Important note: The maximum distance from the change-piece Y-model of the Wehotherm Standard system to the nearest compensatory unit type (, Z, U) must not exceed 12 m, taking into account the effect of expansion. 40 For the latest technical information see our websites 1 / 2015

41 Wehotherm Twins Change-pieces F-model Change-pieces F-model are used to transfer from Wehotherm Standard system to the Wehotherm Twins system or vice versa. It is therefore very important to indicate the desired direction of the transfer and the direction of the turn of the change-piece F-model D bl D To determine the direction of the transfer and of the turn for a specific route, use the following diagram RD = A 1 RU = A 2 Wehotherm Twins A A RD = A 1 RU = A A 2 A Code: 2WTS CPF (insulation class-dn twin pipe/casing diameter) x (insulation class-dn/casing diameter) (direction of the transfer) Ex.: 2 WTS CPF 1-DN40+40/160 x 1-DN40/110 RD Important note: The maximum distance from the change-piece F-model of the Wehotherm Standard system to the nearest compensatory unit type (, Z, U) must not exceed 12 m, taking into account the effect of expansion. 1 / 2015 For the latest technical information see our websites 41

42 Wehotherm Twins Anchors s h 052bl Wehotherm Twins DN (m) s S (cm 2 ) Insulation class 2 Insulation class h = 55 mm, S = area of anchor plate outside the casing s = anchor plate thickness The anchors are designed to be embedded into reinforced concrete blocks. It may also be attached to supporting structures (e.g. welded to steel supports). Code: 2WTS (insulation class) AP (DN/casing diameter) Ex.: 2WTS 1 AP DN80+80/ Elbow anchors Wehotherm Twins elbow anchors are manufactured with both arms of equal length. The dimensions of the anchor plates are similar to those of the anchors (see 3.2.6) Vertical elbow (V) Horizontal elbow (H) 053enbl 1200 Code: 2WTS (insulation class) EA (DN/casing diameter) (H =horizontal or V =vertical) Ex.: 2WTS 1 EA DN65+65/225 H 42 For the latest technical information see our websites 1 / 2015

43 Wehotherm Twins Shut-off valves T-key Manual moment multiplier l D k min 055 D 056 Based on the customer s request, valves are controlled either manually with a T-key (for dimensions of DN20-150), through a manual moment multiplier, or with a complete valve with gearbox (for dimensions of DN DN 250). Wehotherm Twins 054bl DN l D D k min Insulation class 1 Insulation class 2 Insulation class 1 Insulation class Wehotherm Twins shut-off valves DN 20 - DN 250 are manufactured only as long spindle ball valves. Valve Material: - Valve body: carbon steel - Ball: SIS 2333, AISI 304 (stainless steel) - Gasket: PTFE, carbon reinforced - Upper part of spindle: SIS 2333, AISI304 - stainless steel Code: 2WTS (insulation class) S-V (DN/casing diameter) Ex.: 2WTS 1 S-V DN80+80/250 A combined version of the shut-off valve with the air relief or drain valve can be supplied upon request. 1 / 2015 For the latest technical information see our websites 43

44 Wehotherm Twins Drain/Air relief valves l Wehotherm Twins 057bl D k min D DN l D D k min Insulation class 1 Insulation class 2 Insulation class 1 Insulation class The drain and air relief parts of the valves from DN 20 to DN 50 are produced with an increased wall thickness compared to the thickness of standard pipes, for dimension see Chapter Valve Material: - Service pipe: carbon steel P235 GH - Ball: SIS 2333, AISI 304 (stainless steel) - Gasket: PTFE, carbon reinforced Code: 2WTS (insulation class) D/A-V (DN pipe dimension/casing diameter) x (DN air/drain valve dimension) Ex.: WTS 1 D/A-V DN80+80/250 x DN25 A combined version of the shut-off valve with the air relief or drain valve can be supplied upon request. 44 For the latest technical information see our websites 5 / 2015

45 4 Wehotek PPR Polypropylene carrier pipe Rigid polyurethane insulation PE-HD casing pipe Spiro casing pipe PPR Pipes with PE-HD casing PPR Elbows with PE-HD casing T-branches with PE-HD casing Modular PPR reducers with PE-HD casing Wehotek PPR 45

46 Wehotek PPR Polypropylene carrier pipe The carrier pipes are made of polypropylene type 3, designated as PP-R. Density: 908 kg/m 3 Tensile strength: 40 N/mm 2 Yield strength: 25 N/mm 2 Modulus of elasticity: 750 N/mm 2 Thermal conductivity: 0,24 W/mK Thermal expansion coefficient: 1, K -1 Tested for drink water 058 With a maximum working temperature of 70 C and maximum working overpressure of 1 MPa the pipe has a service life of 25 years. For higher operating parameters, please consult the Uponor Infra Fintherm technical department Rigid polyurethane insulation The rigid polyurethane foam (PUR) is produced by mixing polyalcohols (polyols) containing additives and isocyanates (MDI). The mixture is injected into pipes using a high-pressure foaming technique. The PUR foam used in the Wehotek PPR system is CFC-free and meets the stringent requirements of European Standard EN 253. Wehotek PPR Average cell size: 0,5 mm Closed cell content: 88 % Core density: 60 kg/m 3 Compressive strength: 0,3 MPa Shear strength: 0,12 MPa Thermal conductivity (+ 50 C): 0,026 W/mK PE-HD casing pipe Material PE-HD (Polyethylene, high density) Density (+20 C): ~ 960 kg/m 3 Thermal conductivity: 0,43 W/mK Thermal expansion coefficient: 1, K -1 See Chapter Spiro casing pipe Spiro casing pipes are made of spiral overlaid mechanical deep-drawing steel zinc-coated sheets. Other material is available upon request. 038 wts For the latest technical information see our websites 1 / 2015

47 Wehotek PPR Pipes PPR with PE-HD Casing l = 170 ± 10 mm D d s 060bl Insulation class 1 d s D (m) Weight (kg/m) Insulation thickness Water volume (l/m) 32 5, ,5 26 0, , ,1 32 0, , ,4 27 0, , ,2 28 1, , , 12* 4,0 29 1, , , 12* 5,3 32 2, , , 12* 7,0 32 4,21 Wehotek PPR Insulation class 2 d s D * If requested, please consult possibility of 12 m length pipes delivery, with Uponor Infra Fintherm sales representatives. Pipes are supplied in the PN20 pressure range. With the maximum working temperature of 70 C and maximum working overpressure of 1 MPa, the pipe has a service life of 25 years. For higher operating parameters, please consult the Uponor Infra Fintherm technical department. (m) Weight (kg/m) Pipes can be manufactured in different sizes and insulation thicknesses upon special request. Code: PPR P (d carrier pipe outer diameter) / (casing pipe outer diameter) (length) Ex.: PPR 1 P d63 / m Insulation thickness Water volume (l/m) 32 5, ,0 36 0, , ,1 32 0, , ,7 35 0, , ,6 36 1, , , 12* 4,6 40 1, , , 12* 5,9 42 2, , , 12* 7,8 42 4,21 1 / 2015 For the latest technical information see our websites 47

48 Wehotek PPR Pipe PPR with Spiro Casing l = 170 ± 10 mm D d s 061bl Insulation class 1 Wehotek PPR d s Insulation class 2 D (m) Weight (kg/m) Insulation thickness Water volume (l/m) 32 5, ,8 24 0, , ,0 34 0, , ,3 29 0, , ,0 30 1, , , 12* 5,0 32 1, , , 12* 6,5 34 2, , , 12* 8,6 34 4,21 d s D (m) Weight (kg/m) Insulation thickness Water volume (l/m) 32 5, ,8 38 0, , ,7 42 0, , ,0 37 0, , ,0 38 1, , , 12* 6,3 42 1, , , 12* 8,0 44 2, , , 12* 10,2 44 4,21 * If requested, please consult possibility of 12 m length pipes delivery, with Uponor Infra Fintherm technical department. A standard casing pipe is made of spiral overlaid steel zinc-coated sheets. Pipes are supplied in the PN20 pressure range. With a maximum working temperature of 70 C and maximum working overpressure of 1 MPa, the pipe has a service life of 25 years. For higher operating parameters, please consult the Uponor Infra Fintherm technical department. Pipes can be manufactured in different sizes and insulation thicknesses upon special request. Code: PPR (insulation class) P (d dimension of PPR carrier pipe/casing diameter) Spiro (length) Ex.: PPR 1 P d63/125 Spiro 6m 48 For the latest technical information see our websites 1 / 2015

49 Wehotek PPR PPR Elbows with PE-HD casing D 45 d 006bl 063bl 1000 Wehotek PPR prefabricated insulated elbows are manufactured in the following angles: d32 - d63: 45 and 90 d75 - d110: 45 and 90 (supplied with a butt weld; other angles upon special request.) Code: PPR (insulation class) E (d dimension of PPR carrier pipe/casing diameter) (angle) Ex.: PPR 1 E d40/ Wehotek PPR 1 / 2015 For the latest technical information see our websites 49

50 Wehotek PPR T-branches PPR Straight T-branch kits with PE-HD casing k Wehotek PPR The kit comprises: 1. Branch 1 piece 2. Saddle 1 piece 3. Narrow shrink sleeves 2+1 pieces 4. Closing patches 2+1 pieces 5. Venting plugs 2 pieces 6. Welding plugs 2 pieces 7. Centring ring 1 piece - PUR components (quantity according to the dimensions) For installation instruction, see Chapter 6.7. Code: PPR T-kit ST (d dimension of PPR pipe/casing diameter) / (d dimension of PPR branch dimension/ casing diameter) Ex.: PPR 1 T-kit ST d75/140 x d32/90 50 For the latest technical information see our websites 1 / 2015

51 Wehotek PPR PPR Straight T-branches with PE-HD casing Straight T-branch 066plbl 1000 Code: PPR (insulation class) S-T (d dimension of PPR pipe/casing diameter) x (d dimension of PPR branch dimension/casing diameter) Ex.: PPR 1 S-T d110/180 x d75/ PPR Elevated T-branches with PE-HD Casing Wehotek PPR 1000 H 1 H D2 011a 1 D1 H 1 = (D 1 + D 2 ) / 2 + H D 1, D 2 - diameter of the casing of the main pipe and the branch piece 068 H=35 mm distance between the surfaces of the casing pipes Code: PPR (insulation class) E-T (d dimension of PPR carrier pipe/ casing diameter) x (d diameter of PPR branch/ casing diameter) Ex.: PPR 1 E-T d75/140 x d40/110 1 / 2015 For the latest technical information see our websites 51

52 Wehotek PPR Modular PPR reduction kit with PE-HD casing (reduced joints) The reduction kits (for installation in joints) are offered as standard shrinkable version. The advantage of the shrinkable modular reduction kit is that there are two independent systems for sealing a reduced joint. The kit comprises: 1. PE shrinkable casing reducer 1 piece 2. PPR reducer 1 piece 3. Narrow shrink sleeves 2 pieces 4. Closing patches 2 pieces 5. Venting plugs 2 pieces 6. Welding plugs 2 pieces 7. Electrical wire supports 2 pieces 8. Electrical wire connectors 2 pieces 9. Sealing tape - PUR components quantity according to the dimensions) b The PE casing reducer is placed over the smaller casing pipe prior to installation of PPR reducer. Wehotek PPR 020 The subsequent installation procedure of the shrinkable modular reduction kit is similar to the installation procedure for the DSJ double-sealed shrinkable joint. Shrinkable version: Code: WTS PPR DSJ-SRK (PE larger casing diameter/smaller casing diameter) PPR Reducer (larger d/smaller d) Ex.: WTS PPR DSJ-SRK PE160/140 PPR Reducer d110/d63 52 For the latest technical information see our websites 1 / 2015

53 5 Pipe systems for different applications Other materials for pre-insulated pipes WehoArctic Pipe systems for different applications 53

54 Pipe systems for different applications 5 Pipe systems for different applications In addition to the standard Wehotherm and Wehotek systems, we can offer other pre-insulated pipe systems in accordance to specific customer requirements Other materials for pre-insulated pipes Conveyance pipes The material for carrying pipes and pipes for the chemical industry is selected according to the specific application. The following suitable materials are available: - Steel - Stainless steel - Acid-resistant steel - Galvanised steel - Copper - Polyethylene (PE 100) - Polypropylene (PPR) - Polybutene (PB) - Glass-fibre laminates - PEX - Cast iron Casing The casing protects the insulation against moisture and damage and effectively protects the pipes against corrosion. The casing of underground pipes must be watertight. Pipe systems for different applications When selecting the casing, a suitable material for the specific installation must be taken into account, such as: - Polyethylene: for underground installation or also for above-ground installation (provided that the cross-linked joints are used) - Steel-zinc coated or aluminium spiral overlaid sheet (Spiro casing) for above-ground installation - Steel-zinc coated or aluminium spiral overlaid sheet coated with PVC foil for above-ground installation - Plastic-coated steel for demanding applications Insulation PUR foam is used as standard as in the previous types of pipelines for transporting liquids or gases at temperatures ranging from -196 to +142 C. For higher temperatures, pipes containing polyurethane foam with enhanced temperature resistance of up to 165 C are available WehoArctic The WehoArctic pre-insulated plastic pipe system is used for the distribution of drinking water, geothermal energy and others. The media carrying pipe made of PE 100 polyethylene is insulated using rigid polyurethane foam covered with a polyethylene casing or a spiral overlaid steel zinc-coated sheet. The standard series is designed for a media working temperature between -50 C and +50 C. The maximum permissible working pressure depends on the wall thickness of the media-carrying pipe. The WehoArctic system can optionally be fitted with heating cables. 54 For the latest technical information see our websites 1 / 2015

55 6 Accessories 6.1 Expansion polyethylene profile pads 6.2 Channel rubbers 6.3 Marking tapes 6.4 Joints 6.5 PUR foam dosing 6.6 End sealings of insulation 6.7 End fitting kits 6.8 T-branch kits 6.9 Connection pipes 6.10 Valves for pipe tapping 6.11 Polyethylene valve wells 6.12 Valve spindle extenders 6.13 eakage detection systems Accessories 1 / 2015 For the latest technical information see our websites 55

56 Accessories 6.1 Expansion polyethylene profile pads Expansion polyethylene profile pads allow the thermal expansion of pre-insulated pipes installed in the ground. They have to be used at bends, branches, reducers, valves, and end fittings. Material of expansion polyethylene profile pads is cross-linked Polyethylene, which has a long service life because it has increased resistance to the effects of soil moisture and chemicals. The profile pads are cut on-site to the required size according to the outer diameter of the pipes to be sheathed. D 073d Multi layers of expansion pads can be used if it is necessary to handle larger expansion and according to the type of soil, and at the same time it is necessary to sheathe the pipes so as to avoid the accumulation of heat on the pipe casing. In the case of pre-heating, the pre-insulated pipes are covered on both sides. The pipeline dilatation direction Density: 30 ± 4 kg/m Water absorption: vol.% % 1,9 Compressibility 10% at compression of 16 kpa = 4 mm Compressibility 25 % at compression of 35 kpa= 10 mm Compressibility 50 % at compression of 80 kpa= 20 mm Code: WTS FPP (length) x (height) x (width) Ex.: WTS FPP 2000x1000x40 For up to DN 250, we provide pre-cut profiled board segments in the following sizes: Accessories b en Size 1 Size 2 Size 3 40 Casing diameter Size of cut segments Code: WTS FPP (length) x (height) x (width) Ex.: Size 1: WTS FPP 1000x120x40 Size 2: WTS FPP 1000x240x40 Size 3: WTS FPP 1000x360x40 56 For the latest technical information see our websites 1 / 2015

57 Accessories 6.2 Channel rubbers Dimensions: o mm = 50 mm S = 20 mm 074 S 075a The channel rubber is placed around the casing pipe prior to welding and casting the wall entry. The channel rubber is usually situated in the wall entry and functions as a watertight seal. If the wall thickness is greater than 300 mm, we recommend installing two channel rubbers. Code: WTS CR (outer casing diameter) Ex.: WTS CR Marking tape Marking tape is supplied in rolls. Green as standard, but other colours may be available upon request Code: WTS MT (ength in m) Ex.: WTS MT 216 m Accessories 1 / 2015 For the latest technical information see our websites 57

58 Accessories 6.4 Joints Joints are used for the insulation of a pipeline in the welded areas of the carrier pipes, connecting its individual segments. The joints have dual functionality: they protect the PUR insulation against mechanical damage and prevent moisture from entering. Selecting the right type of joints significantly influences the quality and service life of the pipe system. Provided that the installation procedures are followed carefully, all joints offered are suitable for sandy, clay, dry, and wet soil and meet the requirements of EN 489. All materials required for joint installation, including components for the production of polyurethane foam, which comes in bottles, cans, or in the form of prefabricated parts, are provided as standard. To achieve the highest quality of joints for larger dimensions and the correct mechanical and thermal insulating properties, Uponor Infra Fintherm offer mechanical foaming of these joints directly on-site. Types of joints according to their technical performance and application: JT electrically weldable shrinkable joints are suitable for the most demanding conditions with the least favourable load, or for sites with ground water. JZ cross-linked shrinkable joints are designed for most demanding conditions subjected to adverse stress and can also be used in sites where ground water occurs. DSJ double-sealed shrinkable joints are suitable for most applications and this is the most commonly used joint type. Two independent seal systems prevent moisture from entering the PUR insulation. Accessories WE extrusion longitudinally welded joints for repairs are designed for repairs. For installation of WE extrusion longitudinally welded joints it is necessary to extrusion weld the polyethylene. This type of joint can be used on previously welded carrying pipe. 200a See below for more information on joints. 58 For the latest technical information see our websites 1 / 2015

59 Accessories The selection of a specific joint type depends primarily on: - Joint size - Soil factors (level of ground and surface water, oil and other contamination) - Knowledge and experience of the assembly personnel - Number of thermal cycles - Stress rate the joint is exposed to - Service life of the joint - Requirements of the designer and the project investor Thanks to our many years of experience, our sales representatives or engineers will recommend the best type of joint for the project. The joint installation must be done in accordance with EN standards by trained personnel with valid certification from Uponor Infra Fintherm. The certification confirms the theoretical and practical knowledge of installation of pre-insulated pipe joints. This knowledge and practical testing during the training programme helps minimize risks and possible damage which may be incurred by failure to adhere to the correct procedures and to adapt the installation of the joints to the environment. After the training programme, the installation workers will have gained the following knowledge: - Information about the types of joints used and installation procedures - Joint foaming process using cast PUR foam - Safety regulations applicable to the installation of the joints and PUR foam - Storage conditions for the individual components - Disposal of waste generated during the installation of joints - eak detection systems used for pre-insulated pipes (Nordic, Brandes, Hagenuk, and Isotronic) Information on the procedures of joint installation is provided in the installation manual, which is available at Accessories 1 / 2015 For the latest technical information see our websites 59

60 Accessories JT electrically weldable joints After torch heating, the casing shrinks to the outside of the casing pipe. Welding strips with electrical conductors, which are used for the final welding of plastics, are located under the casing. This creates a fixed permanent joint of high quality achieved around the whole perimeter. The entire welding process is controlled by a microcomputer in the welding machine that adapts the welding process to ambient conditions. Electrically weldable JT shrinkable joints includes: 1. Electro shrinkable casing 1 piece 2. Welding resistance wires 2 pieces 3. Venting plugs 2 pieces 4. Welding plugs 2 pieces 5. Detection wire supports 2 pieces 6. Detection wire connectors 2 pieces PUR components (quantity according to the dimensions) 080c JT joints are offered as standard in length of 700 mm. See Chapter 6.5. for the dose rate of PUR components. Code: WTS JT (DN dimension / casing diameter) Ex.: WTS JT DN100/ OB-JT Electrically weldable joint for compensator Electrically weldable joints with a longer casing and with a bigger quantity of PUR foam are intended to insulate one time compensators. Accessories Casing pipe diameter ø mm ø mm ø mm ø mm ø mm ength of the connection 880 mm 950 mm 1080 mm 1120 mm 1260 mm Code: WTS OB-JT (DN dimension/casing diameter) Ex.: WTS OB-JT DN100/ For the latest technical information see our websites 1 / 2015

61 Accessories JZ cross-linked shrinkable joints The cross-linked casing shrinks to the outside of the casing pipe after being torch heated. The crosslinked shrinkable casing has an integrated seal on each side. The casing s material has a high shrinkage rate, which gives the joint a high adherence pressure for the service life of the pipe. It is therefore not necessary to use shrinkable protective sleeves as is the case for the DSJ joint. JZ cross-linked shrinkable joints includes: 1. Cross-linked shrinkable casing 1 piece 2. Venting plugs 2 pieces 3. Welding plugs 2 pieces 4. Detection wire connectors 2 pieces 5. Detection wire supports 2 pieces PUR components (quantity according to the dimensions) The cross-linked heat shrinkable sleeve comes in a protective white foil of polyethylene that protects it from dirt and moisture. The protective foil is removed just before heating the joint. 079ccpl JZ joints are offered in the following standard lengths depending on the diameter of the casing pipe and customer requirements: Casing pipe diameter Code: WTS JZ (DN dimension/casing diameter) Ex.: WTS JZ DN100/200 Accessories ø mm ø mm ength of the connection mm mm See Chapter 6.5. for the dose rate of PUR components. 1 / 2015 For the latest technical information see our websites 61

62 Accessories DSJ double-sealed shrinkable joints The PE casing shrinks to the outside of the casing pipe after being torch heated. Sealing tape is already integrated in the cover casing Shrinkable sealing sleeves covering the edges of the casing are used as additional sealing in accordance with the requirements of standard EN 489 for double-sealed joints. DSJ double-sealed shrinkable joint includes: 1. PE-shrinkable casing 1 piece 2. Narrow shrink sleeves 2 pieces 3. Patches 2 pieces 4. Venting plugs 2 pieces 5. Welding plugs 2 pieces 6. Detection wire connectors 2 pieces 7. Detection wire supports 2 pieces Sealing tape is already integrated in the cover casing. PUR components (quantity according to the dimensions) The shrinkable cover casing comes in a protective white foil of polyethylene that protects it from dirt, moisture, and sunlight. The protective foil is removed just before heating the joint.?? 079c DSJ joints are offered in the following standard lengths according to the diameter of the casing pipe: Casing pipe diameter ø mm ø mm ength of the connection 600 mm 700 mm See Chapter 6.5 for the dose rate of PUR components. See the installation manual for workflow. Code: WTS DSJ (DN dimension/casing diameter) Ex.: WTS DSJ DN100/ OB-DSJ double-sealed shrinkable joint for compensator Double-sealed joints with a longer casing and with a bigger quantity of PUR foam are intended to insulate one time compensators. Accessories Casing pipe diameter ø mm ø mm ø mm ø mm ø mm ength of the connection 880 mm 950 mm 1080 mm 1120 mm 1260 mm Code: WTS OB-DSJ (DN dimension/casing diameter) Ex.: WTS OB-DSJ DN100/ For the latest technical information see our websites 2 / 2016

63 Accessories WE Extrusion welded longitudinal joint for repairs The extrusion welded longitudinal joint is intended solely for repairs. For installation of WE extrusion longitudinally welded joints it is necessary to use extrusion welding for the joining of polyethylene. This type of joint can be used on previously welded carrying pipe. The WE Extrusion welded longitudinal joint includes: 1. PE-non shrinkable casing 1 piece 6. Detection wire supports 2 pieces 2. Narrow shrink sleeves 2 pieces 7. Detection wire connectors 2 pieces 3. Patches 2 pieces PUR components 4. Venting plugs 2 pieces (quantity according to the dimensions) 5. Welding plugs 2 pieces?? 077a See Chapter 6.5 for the dose rate of PUR components. Code: WTS WJ (DN dimension/casing diameter) E.g.: WTS WJ DN100/ Twins joint For the Wehotherm Twins system, we offer all joint types mentioned in Chapters to The only difference is the foam dosage. Change in the way of coding joints 081 Code: 2WTS (joint type) (DN+DN / casing diameter) Ex.: 2WTS DSJ DN40+40/ Accessories for joints Upon the customer s request, we supply individual replacement joint components separately. It is also possible to separately order upper patches for the additional covering of welding plugs. Accessories 1 / 2015 For the latest technical information see our websites 63

64 Accessories 6.5 Dosage of PUR foam Dosage of PUR foam from bottles Calculated values: Density 85 kg/m 3 of polyurethane DSJ joint type ength of the foamed part: 350 mm Components: MDI: Diphenylmethane diisocyanate - dark, viscous, higher quantity Polyol: Polyether alcohol - light, bright, viscous DN Dosage of foam for Wehotherm Standard Insulation class 1 Insulation class 2 Insulation class 3 Casing diameter [mm] Bottle size Casing diameter [mm] Bottle size Casing diameter [mm] Bottle size , , * 10 DN Dosage of foam for Wehotherm Twins Insulation class 1 Insulation class 2 Casing diameter [mm] Bottle size Casing diameter [mm] Bottle size , * * pl Polyol * For the foaming of joints in larger dimensions, we offer the mechanical foaming of these joints directly on-site, to achieve the highest quality of joints and the correct mechanical and thermal insulating properties; alternatively we can supply the foam components in canisters. Accessories Prefabricated PUR insulation foam To request prefabricated insulating foam modules, as an alternative to foam in bottles or canisters, please put a PU abbreviation in your order after the joint specification. The prefabricated insulation modules are used for example at temperature parameters unsuitable for joint installation (hot/cold). Code: WTS DSJ (DN of piping/diameter of casing)-pu Ex.: WTS DSJ DN100/250-PU For the latest technical information see our websites 1 / 2015

65 Accessories Dosage of PUR foam from canisters Calculated values: Density 85 kg/m 3 of polyurethane DSJ joint type ength of the foamed part: DN350 = 350 mm DN400 = 390 mm Components: MDI: Diphenylmethane diisocyanate - dark, viscous, higher quantity Polyol: Polyether alcohol - light, bright, viscous DN Casing diameter [mm] Dosage of foam for Wehotherm Standard Insulation class 1 Insulation class 2 Insulation class 3 Polyol [ l ] Isocyanate [ l ] Casing diameter [mm] Polyol [ l ] Isocyanate [ l ] Casing diameter [mm] Polyol [ l ] Isocyanate [ l ] ,077 0, ,118 0, ,171 0, ,072 0, ,114 0, ,167 0, ,106 0, ,143 0, ,202 0, ,103 0, ,139 0, ,197 0, ,127 0, ,184 0, ,245 0, ,159 0, ,202 0, ,292 0, ,191 0, ,262 0, ,367 0, ,289 0, ,393 0, ,543 0, ,333 0, ,454 0, ,639 0, ,371 0, ,527 0, ,761 1, ,548 0, ,823 1, ,203 1, ,920 1, ,364 1, ,871 2, ,078 1, ,570 2, ,205 3, ,462 2, ,192 3, ,863 4, ,833 2, ,006 4, ,939 5, ,823 2, ,759 3, ,019 7, ,795 2, ,989 4, ,415 9,160 DN Casing diameter [mm] Dosage of foam for Wehotherm Twins Insulation class 1 Insulation class 2 Polyol [ l ] Isocyanate [ l ] Casing diameter [mm] Polyol [ l ] Isocyanate [ l ] ,165 0, ,205 0, ,197 0, ,257 0, ,245 0, ,312 0, ,235 0, ,302 0, ,373 0, ,478 0, ,439 0, ,556 0, ,518 0, ,673 0, ,781 1, ,072 1, ,284 1, ,692 2, ,532 2, ,033 2, ,286 3, ,139 4,482 ISOCYANNATE For foam dosage for different lengths of joints, the quantity of foam components is multiplied by a factor x: 206en POYO Accessories X = new length of the foamed part of the joint standard length of the foamed part of the joint For dosing ratios of larger dimensions, please contact the Uponor Infra Fintherm technical department. 1 / 2015 For the latest technical information see our websites 65

66 Accessories 6.6 End sealings of insulation 082 The end sealing of insulation must be attached to the pipe before welding the inner pipe. End sealing is shrunk by torch flame to protect the pipe end against moisture. Clean and abrade the jacket and pipe surface prior to shrinking. Start shrinking the seal part on the jacket section. et it cool down and fasten before shrinking the part over the steel pipe. Avoid leaving air under the sealing. Code: WTS ES (DN/casing diameter) Ex.: WTS ES DN100/ End fitting kits The end fitting kit is used for the temporary blanking of a pipe. It is assumed that the ends blanked off by the kit will be used for a later extension of an existing route. The end of the heat transfer pipe must be closed off with a pressure steel bottom before foaming. The steel bottom should not touch the end of shrinkable casing. To reduce pipe stressing by pressure caused due to pipe movement in the ground, the face of the end fitting kit must be sheathed with an expansion pad. The end fitting kit includes: 1. Steel bottom min. PN25 1 piece 2. End shrinkable casing 1 piece 3. Centring ring 1 piece 4. Shrink sleeve 1 piece 5. Closing patch 1 piece 6. Venting plugs 2 piece 7. Welding plugs 2 piece 8. Detection wires connector 1 piece 9. Sealing tape 1 piece PUR components (quantity according to the dimensions) Accessories 083bb Code: WTS ECK-DSJ (DN/casing parameter) Ex.: WTS ECK-DSJ DN100/ For the latest technical information see our websites 1 / 2015

67 Accessories 6.8 T-branch kits Wehotherm T-branch kit is designed for the assembly of a branch at any place on an existing pipeline, after removal of insulation from an existing pipe or for making an atypical branch. The mounting branch is designed for welding with a plastic welding extruder; upon request we can supply an option without the need for an extruder c The branch kit includes: 1. Saddle 1 piece 2. Branch carrying pipe 1 piece 3. Centring ring 1 piece 4. Venting plugs 2 pieces 5. Welding plugs 2 pieces 6. Narrow shrink sleeves 2+1 pieces* 7. Closing patches 2+1 pieces* 8. Reduction piece 1 piece* PUR components (quantity according to the dimensions) * Items so marked are included in the branch kit only if the branching off pipe is in the first insulation class (due to larger tapping valves and lesser insulation thickness it is typical to use a casing branch pipe with a larger diameter, which must be then reduced). Installation: 1) 2) 1) Remove the insulation in the area of the future branch and weld on the tapping valve. After this, Uponor Infra Fintherm installers carry out the tapping of the pipe. 2) Before the medium-carrying branch pipe is welded on the tapping valve, adjust its length as required. 3) Weld the branch pipe onto the welded valve. 3) 4) 4) Cut the saddle lengthwise (in a place accessible to the welding extruder), put it on the branch centred with a centring ring, wrap the saddle tightly around the pipe, and pull it tight with straps g 5) 6) Elevated model (E) Horizontal model (H) 5) Weld the lengthwise slit seat with the extruder for plastic welding. 6) The remaining procedure for the closure with the shrink bands is the same as for the extrusion welded longitudinal joint for repairs. If the branch is in the first insulation class, pull the diameter reducer on the end of the branch and secure it in position with shrink bands and a closing strap. Accessories Code: WTS T-kit (insulation class - DN of the main piping/casing diameter) x (insulation class - DN of the branch/casing diameter) (model E or H) Ex.: WTS T-kit 1-DN100/200 x 1-DN25/90 E 1 / 2015 For the latest technical information see our websites 67

68 Accessories 6.9 Connection pipes a ø D The connection pipes are used as an outlet for pre-insulated branches from concrete ducts. It ensures water tightness and enables axial movement of the main pipe in a concrete duct. The kit includes: 1. Connection PE-HD pipe 1 piece 2. Channel rubber 1 piece 3. Narrow Shrink sleeve 1 piece 4. Closing patch 1 piece Code: WTS CP (casing diameter) Ex.: WTS CP 125 Diameter of the casing pipe D ø Accessories 68 For the latest technical information see our websites 1 / 2015

69 Accessories 6.10 Valves for pipe tapping DN 089 H 088 Standard reduced hot tapping valves: DN Inner pipe diameter DN H Full-flow hot tapping valves: 087en This equipment enables drilling a branch hole into a pressurized pipe (hot tapping) without any need to drain the medium. When drilling the tap hole, the drill passes through a ball valve, which is welded on to the main pipe as a branch. The diameter range of the branch pipe that can be achieved with pipe tapping is from DN 20 to DN 200. Uponor Infra Fintherm offers reduced or full-flow tapping versions. The tapping branch is additionally insulated with the T-kit (e.g., the Elevation model); see Chapter 6.8. DN Inner pipe diameter DN H Accessories Important note: When tapping is performed, the temperature of the medium must not exceed 60 C and its maximum permissible pressure is 0,5 MPa. 1 / 2015 For the latest technical information see our websites 69

70 Accessories 6.11 Polyethylene valve wells Cast iron cover (typ 1-25t, typ 2-40t) Telescopic part en Other sizes can be manufactured upon special request. Code: WTS PE- well (800/900) (well cover type) Ex.: WTS PE-weIl (inner/outer diameter), Accessories The advantage of this solution is that the load from the vehicles travelling on the shaft cover is not transferred to the operating piping, thanks to the use of this telescopic system. 70 For the latest technical information see our websites 1 / 2015

71 Accessories 6.12 Valve spindle extenders Valve spindle extenders are used for cases in which a normal pre-insulated valve spindle is too short. A telescopic or fixed version can be supplied. Due to the transfer of high torque values, it is recommended to use the fixed version of the extension for dimensions larger than DN 250. Important notice: Expansion of the valve in the shaft must be allowed for. When laid in ground, the entire valve rod must be sheathed with expansion pads. Material of the valve rod extensions: - PE extension casing - Internal galvanized steel mechanism (stainless steel version upon request) Telescopic valve spindle extender The telescopic extension of the valve can be extended by about 2/3 of its original length. This original length may range from 0,3 to 3 m. The connection between the hexagon socket of the valve and the Telescopic valve spindle extender is secured by the split pin supplied. The telescopic extension and the spindle of the valve is covered by a protection pipe, which is sealed with a narrow shrink sleeve and closing patch. 094bl The telescopic extension of the valve rod includes: 1. Telescopic extension of the valve spindle 2. Split pin 3. PE protection pipe 4. Narrow Shrink sleeve 5. Closing patch Code: WTS SPE TEESCOPE (DN of the valve) x (diameter of the PE protection pipe) (=length) (valve manufacturer) Ex.: WTS SPE TEESCOPE DN80 x 125 = 1 m Broen Solid valve spindle extender The solid rod extension is supplied in lengths from 0,3 to 4 m. The Solid valve spindle extender and valve spindle is covered by a protection pipe, which is sealed with a narrow shrink sleeve and Closing patch. 1 The solid extension of the valve rod includes: 1. Solid extension of the valve spindle 2. PE protection pipe 3. Narrow Shrink sleeve 4. Closing patch Accessories bl1 Code: WTS SPE (DN of the valve) x (diameter of the PE protection pipe) (=length) (valve manufacturer) Ex.: WTS SPE DN80 x 125 = 1 m Broen 1 / 2015 For the latest technical information see our websites 71

72 Accessories 6.13 eakage detection system Wehotherm pipe systems are manufactured with Nordic system detection wires as a standard, in line with EN We can supply pipes with other types of detection wires (e.g., Brandes, Hagenuk, and Isotronic) upon request Detection principle Pre-insulated pipe systems enable the electronic detection of any leakage of the carrier pipe and its casing. Detection wires serve as sensors, and are located in the insulation foam together with the carrier pipe. AII pipes and joints are equipped with at least two wire sensors which connect into seamless sections in order to monitor the whole system. Special sensors are then connected to the individual sections. Conductometry Conductometry, i.e., the measurement of the electric conductivity of fluids, is the basis of operation for all sensor types. eakage of fluid into the piping insulation layer creates a bridge between a detection wire and the pipe (or between two wires). If acceptable leakage is exceeded, a defect is signalled. Reflectometry The highest class in the field of leakage sensors consists of instruments operating on the principle of reflectometry - the measurement of electric signal reflections in a conductor. A defect (wet insulation, broken wire, short-circuit) is a disturbed electric homogeneity which induces a partial or total reflection of the electronic impulse, from which the instrument determines the nature and location of the fault. Thanks to conductometry, it is also possible to measure electric capacity changes caused by fluids gradually proceeding through the foam towards the detection wires (before contact) Sensors Sensors can be divided into stationary and portable types based on the method of their use, and in turn into indicatory and localization types based on their ability to determine the distance of the fault. Stationary sensors - located inside a suitable structure for permanent monitoring Portable sensors - designed for operational measurements in any part of the system Indicator sensors - only warn about a fault in a controlled section ocalization sensors - able to determine fault location as well Selection of the detection system Accessories An appropriate measuring device must be determined for each type of leak detection system for the pre-insulated piping. Please contact the Uponor Infra Fintherm technical department, who will help you select the appropriate type according to your requirements and the sensor wires used. 72 For the latest technical information see our websites 1 / 2015

73 7. Quality and Certifications 1 / 2015 For the latest technical information see our websites 73 Quality and Certifications

74 Quality and Certifications 7 Quality and Certifications A satisfied customer is Uponor Infra Fintherm s priority, so it puts an emphasis on excellent quality and a continuous improvement process. All manufacturing materials and final products are subjected to thorough tests in the company s state-of-the-art laboratory staffed with experienced personnel. Uponor Infra Fintherm has been approved by loyd s Register Quality Assurance to the following Quality, Environmental and Safety Management System Standards for scope which is applicable to Design and manufacture of thermal pre-insulated pipe system: ISO Quality Management Certification, ISO Environmental Management Certification. OHSAS Management System for Safety and Protection All products meet the requirements of EN 253, 448, 488 EN , and 489 European standards, as documented by a series of certificates from Czech and foreign test laboratories. The internationally recognized European Association Certification for EHP (EUROHEAT & POWER) and the German Association AGFW, which covers all the requirements for district heating products, are also evidence of the company s high quality standards. Uponor Infra Fintherm is accredited by institute for installation joints assembly according to German standards FW 603 and FW 605 and in compliance with the AGFW. IMS (ISO & OHSAS) EUROHEAT & POWER TZÚS FW 605 Quality and Certifications 74 FERNWÄRME FORSCHUGSINSTITUT For the latest technical information see our websites 1 / 2015

PRODUCT CATALOGUE DOUBLE PREINSULATED PIPES

PRODUCT CATALOGUE DOUBLE PREINSULATED PIPES PN-EN 15698-1 ITB Technical Approval AT-15-7772/2008+ Annex no.1 Validity term: September 30, 2013 Issued by the Building Research Institute in Warsaw Preinsulated Pipe System To Be Used In Buried Thermal

More information

Table of Contents 2.0 COOLFLEX CLX. 2.0 Table of Contents

Table of Contents 2.0 COOLFLEX CLX. 2.0 Table of Contents Table of Contents CLX 2.0 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 range, DN 20 - DN 125 / SDR 11 (coils) 2.2 Planning, design

More information

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents Table of Contents 6.0 6.0 Table of Contents 6.100 System description 6.105 Medium pipe 6.106 Heat insulation, casing pipe, monitoring wires 6.115 District heating pipe UNO 6. Planning, design engineering

More information

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents Table of Contents 6.0 6.0 Table of Contents 6.100 System description 6.105 Medium pipe 6.106 Heat insulation, casing pipe, monitoring wires 6.115 District heating pipe UNO 6. Planning, design engineering

More information

CALPEX Low Temperature System

CALPEX Low Temperature System CALPEX Low Temperature System Flexibly towards a safe future Nou! Ø 125/182 Ø 160/250 Contents Utilise your advantages 3 System description 4 6 Pressure loss 7 Heating range 8 19 Dimension of pipe UNO/DUO

More information

Table of Contents. EIGERFLEX -Clima. 2.0 Table of Contents

Table of Contents. EIGERFLEX -Clima. 2.0 Table of Contents 2.0 Table of Contents 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 -Clima range, DN 20 - DN 125 / SDR 11 (coils) 2.120 -Clima range,

More information

ZPU MIĘDZYRZECZ Sp. z o.o. PREINSULATED PIPE SYSTEM TYPE SPIRO

ZPU MIĘDZYRZECZ Sp. z o.o. PREINSULATED PIPE SYSTEM TYPE SPIRO TECNICAL CERTIFICATE OF APPROVAL NR AT-15-8619/2015 EXPIRES: June 23, 2020 ISSUED BY: ITB WARSAW ZPU MIĘDZYRZECZ Sp. z o.o. PREINSULATED PIPE SYSTEM TYPE SPIRO ZAKŁAD PRODUKCYJNO USŁUGOWY Międzyrzecz Polskie

More information

Table of Contents COOLMANT. 2.0 Table of Contents

Table of Contents COOLMANT. 2.0 Table of Contents CLM 2.0 Table of Contents 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 COOLMANT range, Ø 125 - Ø 315 / SDR 11/SDR 17 (bars) 2.2

More information

Table of Contents 2.0 EIGERFLEX CPE. 2.0 Table of Contents

Table of Contents 2.0 EIGERFLEX CPE. 2.0 Table of Contents Table of Contents 2.0 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 DN 20 - DN 40 with frost protection strip, Ø carrier pipe 25-50

More information

ZPU MIĘDZYRZECZ Sp. z o. o. PREINSULATED PIPE SYSTEM TO BE USED IN BURIED THERMAL UTILITIES

ZPU MIĘDZYRZECZ Sp. z o. o. PREINSULATED PIPE SYSTEM TO BE USED IN BURIED THERMAL UTILITIES POLIS STANDARDS PN-EN 253, PN-EN 448, PN-EN 488, PN-EN 13941, PN-EN 14419 TECNICAL CERTIFICATE OF APPROVAL No AT/2005-02-1532; EXPIRES: 17 AUGUST, 2010 No AT/2005-02-1537; EXPIRES: 29 AUGUST, 2010 ISSUED

More information

ZPU Międzyrzecz Sp. z o.o. ZPU MIĘDZYRZECZ SP. Z O.O. SYSTEM PREINSULATED PIPES FOR LOW TEMPERATURE UTILITIES FLEXIBLE PIPESYSTEMS

ZPU Międzyrzecz Sp. z o.o. ZPU MIĘDZYRZECZ SP. Z O.O. SYSTEM PREINSULATED PIPES FOR LOW TEMPERATURE UTILITIES FLEXIBLE PIPESYSTEMS ZPU Międzyrzecz Sp. z o.o. ZPU MIĘDZYRZECZ SP. Z O.O. SYSTEM PREINSULATED PIPES FOR LOW TEMPERATURE UTILITIES FLEXIBLE PIPESYSTEMS M-Pex M-Pex ZPU MIĘDZYRZECZ SP. Z O.O. SYSTEM PREINSULATED PIPES FOR

More information

Table of contents. PREMANT DUO district heating pipe. 7.0 Table of contents

Table of contents. PREMANT DUO district heating pipe. 7.0 Table of contents 7.0 Table of contents 7.0 Table of contents 7.100 System description 7.105 Medium pipe 7.106 Heat insulation, casing pipe, monitoring wires 7.210 Heat loss, insulation thickness 1 7.211 Heat loss, insulation

More information

The bonded pipe system Overview

The bonded pipe system Overview 2.0.0.1 Overview Introduction This section contains a description of the preinsulated single s which LOGSTOR offers. Contents Material specifications 2.0.1 District heating s, insulation series 1 2.0.2

More information

4.0 Table of Contents. CASAFLEX district heating pipe CFL

4.0 Table of Contents. CASAFLEX district heating pipe CFL Table of Contents 4.0 4.0 Table of Contents 4.1 System description 4.100 System description (general) 4.105 System description (data) 4.115 CASAFLEX UNO range, heating, 16 to 25 bar 4.120 CASAFLEX DUO

More information

piece of straight pipe with a minimum length of 25 cm. (see figure 13) For this purpose the 45 long bend is included in the Wavin AS program.

piece of straight pipe with a minimum length of 25 cm. (see figure 13) For this purpose the 45 long bend is included in the Wavin AS program. Recommendations 3.9 Sound insulation recommendations National / Local building regulations should be observed where applicable. In order to achieve optimal sound insulation it is highly recommended to

More information

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents 1.1 System description 1.100 System description (general) 1.105 System description (data) 1.106 System description (data) 1.110 Long-term behaviour/lifetime

More information

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents 1.1 System description 1.100 System description (general) 1.105 System description (data) 1.106 System description (data) 1.110 Long-term behaviour/lifetime

More information

PIPE LOG BOOK. Project no:... Project:... Construction section:... On behalf of:... Commissioned by:... Order no:... Date:... Construction period:...

PIPE LOG BOOK. Project no:... Project:... Construction section:... On behalf of:... Commissioned by:... Order no:... Date:... Construction period:... FW-FERNWÄRME-TECHNIK GmbH Grafftring 2-6 D-29227 Celle Tel.: + 49 5141 888 88-0 Fax: + 49 5141 888 88-22 E-Mail: info@fw-gmbh.de Internet: www.fw-gmbh.de PIPE LOG BOOK... Project:... Construction section:...

More information

GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS...

GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS... CONTENTS 1. GENERA INFORMATION ABOUT THE USE OF PREINSUATED PIPES AND FITTINGS.... 3 2. SPECIFICATION OF MATERIAS USED IN THE PRODUCTION OF ZPU MIEDZYRZECZ PREINSUATED PIPES AND FITTINGS... 4 3. PIPEINE

More information

Table of Contents. CALPEX district heating pipe

Table of Contents. CALPEX district heating pipe 1.0 Table of Contents 1.0 Table of Contents 1.1 System description 1.100 System description (general) 1.105 System description (data) 1.110 Long-term behaviour/lifetime calculation 1.115 CALPEX UNO/DUO

More information

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents Table of Contents 1.0 1.0 Table of Contents 1.1 System description 1.100 System description (general) 1.105 System description (data) 1.106 System description (data) 1.110 Long-term behaviour/lifetime

More information

Hiline Steel Metric Catalogue

Hiline Steel Metric Catalogue iline Steel Metric Catalogue Table of Contents 1 Specification for CPV iline-zpum Preinsulated Steel Pipes... 2 Specification for Thermal nsulation... 3 Surveillance System...... 4 General Principles of

More information

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents

Table of Contents. CALPEX district heating pipe. 1.0 Table of Contents district heating pipe 1.0 Table of Contents 1.0 Table of Contents 1.1 System description 1.100 System description (general) 1.105 System description (data) 1.110 Long-term behaviour/lifetime calculation

More information

PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS

PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS WWW.PSI-PRODUCTS.COM 111 PSI Casing End Seals Pipes carrying

More information

h Technical Product Data CC Pressure Pipe Systems

h Technical Product Data CC Pressure Pipe Systems h Technical Product Data CC Pressure Pipe Systems Amiblu Holding GmbH All rights reserved. Publication: 09/2018 This version replaces all previous versions. For all current data please visit our website

More information

RAUVITHERM AND RAUTHERMEX PRE-INSULATED PIPES FOR DISTRICT HEATING PARTS LIST ENERGY EFFICIENCY. Building Solutions Automotive Industry

RAUVITHERM AND RAUTHERMEX PRE-INSULATED PIPES FOR DISTRICT HEATING PARTS LIST ENERGY EFFICIENCY. Building Solutions Automotive Industry RAUVITHERM AND RAUTHERMEX PRE-INSULATED PIPES FOR DISTRICT HEATING PARTS LIST ENERGY EFFICIENCY Valid from 01. April 2014 817302 EN Subject to Technical Alterations www.rehau.uk/districtheating Building

More information

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin.

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin. GRP backing flanges DIN 2501 Flange connecting dimension PN10 1310-WN-en 06 10.2002 GRP backing flanges made of Polyester resin. D 45 e d2 d1 b1 k Flange connecting dimensions according to DIN 2501 Part

More information

PE-HDXc pipes (physically cross-linked polyethylene pipes)

PE-HDXc pipes (physically cross-linked polyethylene pipes) pipes (physically cross-linked polyethylene pipes) Applications: Domestic drinking water installations, radiator connections and surface regulation Special properties high chemical resistance (according

More information

Aim higher. Soil & Waste System

Aim higher. Soil & Waste System Aim higher Soil & Waste System Driven by durability FACT Trend towards prefabrication In most countries the labour costs are becoming an increasing part of the total installed cost of a project. To keep

More information

PIPINGSOLUTIONS, INC.

PIPINGSOLUTIONS, INC. Piping Stress Analysis Where do I start? The following information will take you step-by-step through the logic of the data collection effort that should occur prior to beginning to model a piping system

More information

h Technical Product Data FW Pressure Pipe Systems

h Technical Product Data FW Pressure Pipe Systems h Technical Product Data FW Pressure Pipe Systems E Engineering GmbH All rights reserved. Publication: 10/2012 All rights reserved. No part of this document may be reproduced or utilized in any form or

More information

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGIA SUKCESU ISO 9001

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGIA SUKCESU ISO 9001 Ø 16 110 mm SYSTEM KAN-therm PP High quality for reasonable price TECHNOLOGIA SUKCESU ISO 9001 Contents 3 KAN-therm PP System The material... 102 Sanitary systems installation... 102 Pipes... 103 Thermal

More information

Expansion Joint. Ball Joint Flexible Joint

Expansion Joint. Ball Joint Flexible Joint Ball Joint Flexible Joint 255 Selection Ball Joint Selection Flexible Joint Selection 0.98 1.0 2.0 274 274 276 276 275 275 EB-1J EB-2J ES-10 ES-11 EB-11 EB-12 Type Bellows Sleeve Max. Pressure (MPa) 10

More information

VALSIR SUPPLY SYSTEMS MIXAL

VALSIR SUPPLY SYSTEMS MIXAL TECHNICAL DATA SHEET VALSIR SUPPLY SYSTEMS MIXAL The product Mixal is an extremely flexible multilayer pipe and is therefore ideal for the creation of floor, wall and ceiling radiant heating and cooling

More information

PIPE CLAMPS & FLANGES

PIPE CLAMPS & FLANGES PIPE CLAMPS & FLANGES Clamping of pipes in installations is required for purposes of damping vibrations, providing support to the installation and preventing loosening of joints and welds. INTRODUCTION

More information

RAUFUSION PP-R PLUMBING SYSTEM. Safer. Smarter. More Convenient

RAUFUSION PP-R PLUMBING SYSTEM. Safer. Smarter. More Convenient RAUFUSION PP-R PLUMBING SYSTEM Safer. Smarter. More Convenient SAFER Engineered for your safety and well being Safety is critical when choosing a suitable plumbing system. REHAU RAUFUSION consists of a

More information

LOGSTOR FlexPipe System

LOGSTOR FlexPipe System VERSION 2018.10a PexFlextra LOGSTOR FlexPipe System Handbook - design, products and installation AluFlextra CuFlex Biomass plant Residential area School premises SteelFlex Agricultural buildings defining

More information

Combi-Seal Flange Isolation Gaskets 4 pipes

Combi-Seal Flange Isolation Gaskets 4 pipes Combi-Seal lange Isolation Gaskets 4 pipes Pipeline Accessories lange Isolating Technology 4 pipes Isolating flange gaskets 4 pipes are especially designed for: Carbon steel Stainless steel Contact Corrosion

More information

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN Technical Data Sheet Issue: 20-02-2017 PUR-O-STOP FS-L General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN 1504-5 Properties: PUR-O-STOP FS-L is a slow-hardening,

More information

GH Hydro Kits. Technical Information. Ref: N

GH Hydro Kits. Technical Information. Ref: N GH Hydro Kits Ref: N-27167 0507 Technical Information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory

More information

+GF+ CLASS 267. Factory Mutual Approved. HDPE Pipe & Pipe Fittings GEORG FISCHER PIPING SYSTEMS centralplastics.

+GF+ CLASS 267. Factory Mutual Approved. HDPE Pipe & Pipe Fittings GEORG FISCHER PIPING SYSTEMS centralplastics. Factory Mutual Approved CLASS 26 HDPE Pipe & Pipe Fittings CENTRAL PLASTICS 8.499.692 Table Of Contents 18-1 Design-Flow HDPE IPS HDPE Pipe (Iron Pipe ) 4-24 18-2 PE 368 HDPE Physical Properties - FM 18-3

More information

10. Universal Clips. 254 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

10. Universal Clips. 254 Product overview 2013 We reserve the right to change designs and technical specifications of our products. 10. Universal lips Whether you need ceiling, wall or floor mounted clips, Flamco has the solution. We offer a wide range of universal mounting clips with a variety of closures, connections and finishes.

More information

POLYETHYLENE High Density

POLYETHYLENE High Density POLYETHYLENE High Density PE-3408/PE-3608 ENGINEERED FOR WATER AND MINING PIPING SYSTEMS PLASTIC MANUFACTURES SINCE 1953 POLYTUBES HIGH MOLECULAR WEIGHT (HMW) High Density Polyethylene Pipe for General

More information

PSI Anti-Corrosion Tape

PSI Anti-Corrosion Tape General information Technical specifications Requirement evaluation Application instructions Certificates PSI Anti-Corrosion Tape 8 Pipeline Accessories 85 The Systems PSI anti-corrosion tapes have been

More information

COOLSAFE Pre-Insulated PE Piping System

COOLSAFE Pre-Insulated PE Piping System COOLSAFE Pre-Insulated PE Piping System Pipe Fittings Valves Installation COOLSAFE PE piping system provides a cost effective way for installing insulated piping for a broad range of industries. Pipe and

More information

DIN EN : (E)

DIN EN : (E) DIN EN 13480-3:2017-12 (E) Metallic industrial piping - Part 3: Design and calculation Contents Page European foreword... 10 1 Scope... 12 2 Normative references... 12 3 Terms, definitions, symbols and

More information

Grooved gaskets. Types of gaskets

Grooved gaskets. Types of gaskets Types of gaskets have proven extremely useful in all areas of industry, including the most demanding sealing tasks. Our grooved gaskets can be found in conventional power plants as well as in the primary

More information

MATERIAL DATA SHEET* ALPANA d.o.o.

MATERIAL DATA SHEET* ALPANA d.o.o. MATERIAL DATA SHEET* ALPANA d.o.o. Contents H-Pur Material Data Sheet... 2 LT-Pur Material Data Sheet... 3 S-Pur Material Data Sheet... 4 XH-Pur Material Data Sheet... 5 XSH-Pur Material Data Sheet...

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS PAGE : 1 / 13 4. PRESSURISER 4.1. DESCRIPTION The pressuriser (PZR) is a pressurised vessel forming part of the reactor coolant pressure boundary (CPP) [RCPB]. It comprises a vertical cylindrical shell,

More information

Elite. KSB Australia Pty Ltd. Centrifugal Pump

Elite. KSB Australia Pty Ltd. Centrifugal Pump Type Series Booklet Elite Centrifugal Pump Application The Ajax Elite centrifugal pump is suitable for handling water and similar liquids mainly used in the following applications. -Water Supply -Air conditioning

More information

gabotherm gabotherm gabotherm Pipes PB Polybutene Pipes 13 PE-Xc Pipes 15 PE-RT Pipes 16 MV Pipes (Multilayer Composite Pipes) 17

gabotherm gabotherm gabotherm Pipes PB Polybutene Pipes 13 PE-Xc Pipes 15 PE-RT Pipes 16 MV Pipes (Multilayer Composite Pipes) 17 gabotherm Pipes gabotherm PB Polybutene Pipes 13 PE-Xc Pipes 15 PE-RT Pipes 16 MV Pipes (Multilayer Composite Pipes) 17 SR Pipes (Protective Pipes) 18 7 gabotherm Rohre Polybutene Pipes: Polybutene is

More information

PIG VALVES NPS 6 20 Class

PIG VALVES NPS 6 20 Class PIG VALVES NPS 6 20 Class 150-900 APPLICATION Pig valves are designed for loading and receiving cleaning pigs and detecting tools at pipelines transporting: natural gas; oil products. Operating temperature

More information

CONEX Works, Santry Avenue, Dublin 9, Ireland Tel: (0) Fax: (0)

CONEX Works, Santry Avenue, Dublin 9, Ireland Tel: (0) Fax: (0) CONEX Works, Santry Avenue, Dublin 9, Ireland Tel: 00 353 (0)1 842 6255 Fax: 00 353 (0)1 842 6134 Email: sales@sanbra.ie MULTILAYER PIPING SYSTEMS I.S. EN ISO 21003-1:2008 NSAI Certified PRODUCT OVERVIEW

More information

Profile series I-40. System kit Profile series I-40

Profile series I-40. System kit Profile series I-40 Profile series I-40 System kit Profile series I-40 n n n a n n n R n a R 45 Profile series I-40 Contents 1 Technical data/profile machining F f Page 1 2 Page 1 3 Page 1 5 Page 1 8 Profiles Page 2 2 3000

More information

raugeo ground-source systems innovative heating & cooling solutions parts list /11 EN ENERGY EFFICIENCY Building Solutions Automotive Industry

raugeo ground-source systems innovative heating & cooling solutions parts list /11 EN ENERGY EFFICIENCY Building Solutions Automotive Industry raugeo ground-source systems innovative heating & cooling solutions parts list 827300/11 EN ENERGY EFFICIENCY www.rehau.co.uk/groundsource Valid from May 2013 Subject to Technical Alterations Building

More information

British Standard institute-bs Valve Standards

British Standard institute-bs Valve Standards BS 341-1:1991 Transportable gas container valves. Specification for industrial valves for working pressures up to and including 300 bar (REPLACED by BS EN 14189:2003), BS 341-3:2002), BS EN 849:1997),

More information

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS SECTION 15160 - PUMPS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

Champion Fiberglass, Inc. is the leading manufacturer of fiberglass conduit, Flame Shield and bridge hangers for electrical and mechanical markets.

Champion Fiberglass, Inc. is the leading manufacturer of fiberglass conduit, Flame Shield and bridge hangers for electrical and mechanical markets. Champion Fiberglass, Inc. is the leading manufacturer of fiberglass conduit, Flame Shield and bridge hangers for electrical and mechanical markets. Champion Fiberglass began production of epoxy fiberglass

More information

argco.com

argco.com 800-854-1015 argco.com STRUT SUPORT SYSTEM STRUT SUPPORT CHANNEL US Strut Support Channel Quick, strong attachment of single or multiple pipes horizontally or vertically Unlimited applications - range

More information

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Conveyors slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Application example conveyors Transport solutions and goods provision 1 2 3 4 5 6 7 8 362 9 1 slide strips Low-wear

More information

Materials: Parts of the pump in contact with the liquid are manufactured from the following standard

Materials: Parts of the pump in contact with the liquid are manufactured from the following standard Plastic Centrifugal Pump For Chemical Process DIN EN 22858 (ISO 2858)Standard DESCRIPTION pumps are manufactured to DIN EN 22858 (ISO 2858) standards in respect of design, performance and dimensions. They

More information

DESIGN OF MACHINE MEMBERS - I

DESIGN OF MACHINE MEMBERS - I R10 Set No: 1 III B.Tech. I Semester Regular and Supplementary Examinations, December - 2013 DESIGN OF MACHINE MEMBERS - I (Mechanical Engineering) Time: 3 Hours Max Marks: 75 Answer any FIVE Questions

More information

ALUMINIUM PROFILE SYSTEM SERIES 40

ALUMINIUM PROFILE SYSTEM SERIES 40 ALUMINIUM PROFILE SYSTEM SERIES With the basic grid mm (slot 5); mm (slot 6), 16mm, mm and 0mm (slot ). In addition to this, the complete connection technology and a large range of accessories. TABLE OF

More information

ARMYLOR PTFE BELLOWS & COMPENSATORS

ARMYLOR PTFE BELLOWS & COMPENSATORS ARMYLOR PTFE BELLOWS & COMPENSATORS CONTENT MERSEN ANTICORROSION EQUIPMENT p.2 RANGE OF BELLOWS & COMPENSATORS p.3 REFERENCES p.4 TECHNICAL SPECIFICATIONS p.5-6 BELLOW FLANGES p.7 COMPENSATOR FLANGES p.8

More information

Long products and wire rod

Long products and wire rod production prograe Long products and wire rod Mittal Steel Ostrava a.s. production prograe Long products and wire rod Mittal Steel Ostrava a.s. Mittal Steel Ostrava a.s. TRADITIONAL PRODUCER OF THE HIGH

More information

SYSTEM KAN-therm Push Platinum

SYSTEM KAN-therm Push Platinum SYSTEM KAN-therm Push Platinum ISO 9001 TECHNOLOGY OF SUCCESS Contents Page System KAN-therm Push Platinum - General information... 3 Multi-layer PE-Xc/Al/PE-HD Platinum pipes... 5 Parameters of multi-layer

More information

VERSAFLOW MAG 4000 Quick Start

VERSAFLOW MAG 4000 Quick Start VERSAFLOW MAG 4000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. CONTENTS VERSAFLOW MAG 4000

More information

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15 UNA 13 UNA 15 UNA 15 Stainless Steel Design Installation Instructions 810604-01 Steam Traps UNA 13, UNA 15 1 Contents Important Notes Page Use... 7 Safety note... 7 Danger... 7 Explanatory Notes Scope

More information

Herz Valves UK Ltd. Pre-insulated Pipe Catalogue

Herz Valves UK Ltd. Pre-insulated Pipe Catalogue Herz Valves UK Ltd Pre-insulated Pipe Catalogue June 2008 This catalogue introduces a range of pre-insulated pipe products for district heating schemes. Herz Valves UK Ltd are the sole UK distributor for

More information

Ford Fabricated Steel Products

Ford Fabricated Steel Products Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas

More information

Expansion Joints Guide Module 2a - Axial Expansion Joints General - Standard Program (EFB) - Installation Instructions

Expansion Joints Guide Module 2a - Axial Expansion Joints General - Standard Program (EFB) - Installation Instructions Expansion Joints Guide Module 2a - Axial Expansion Joints General - Standard Program (EFB) - Installation Instructions BOA Expansion Joints Guide Expansion Joints Guide Summary Module 2a 1 AXIAL EXPANSION

More information

Expansion Joint Ball Joint Flexible Joint

Expansion Joint Ball Joint Flexible Joint Ball Joint Flexible Joint -1 Step 0 Type/Structure/Features Please refer to this for structure and feature of Expansion Joint, Ball Joint, and Flexible Joint. Step 1 Selection Please look at the ID chart

More information

B U I L D I N G C O N N E C T I O N S T H AT L A S T

B U I L D I N G C O N N E C T I O N S T H AT L A S T B U I L D I N G C O N N E C T I O N S T H AT L A S T pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior

More information

RAUGEO GROUND-SOURCE SYSTEMS INNOVATIVE HEATING & COOLING SOLUTIONS PARTS LIST /12 EN

RAUGEO GROUND-SOURCE SYSTEMS INNOVATIVE HEATING & COOLING SOLUTIONS PARTS LIST /12 EN RAUGEO GROUND-SOURCE SYSTEMS INNOVATIVE HEATING & COOLING SOLUTIONS PARTS LIST 827300/12 EN www.rehau.co.uk/groundsource Valid from 01.04.2014 Subject to Technical Alterations Building Solutions Automotive

More information

Thermoplastic Centrifugal pump, Type NM

Thermoplastic Centrifugal pump, Type NM Thermoplastic Centrifugal pump, Type NM acc. to DIN 24256, EN 22858 and ISO 2858 Size: 32-125 up to 150-400 Capacity Q: up to 450 m 3 / h Head H: up to 100 m Operating temperature t: PE up to + 70 C PP

More information

Reinforced edge channels KE-100

Reinforced edge channels KE-100 Drainage with system Technical data sheet Reinforced edge channels KE-100 ANRIN SERVICE provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation

More information

Volute pumps for hot water up to 230 C

Volute pumps for hot water up to 230 C Volute pumps for hot water up to 230 C SIHI SuperNova ZEND 031125... 125250 TECHNICAL DATA Output: Delivery head: Speed: max. 600 m³/h max. 90 m max. 3600 rpm Temperature: max. 230 C (1) Casing pressure:

More information

TABLE OF CONTENTS SERIES 40

TABLE OF CONTENTS SERIES 40 TABLE OF CONTENTS SERIES ALUMINIUM PROFILES SERIES PAGE Technical data and profile cross-sections 2.4-2.17 Processing of profiles for connectors 2.1-2.19 Prices of aluminium profile processing 2. Aluminium

More information

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled Base - polyurethane - two-component Use - for the bonding of metal, plastic and sometimes even elastomers -

More information

Boiler Feed Booster Pump YNK. Type Series Booklet

Boiler Feed Booster Pump YNK. Type Series Booklet YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any

More information

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. SECTION 221513 - COMPRESSED-AIR PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. 1.2

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

Components: Dimensions / Order Codes Clamp Body. * 1st part of STAUFF Group 4. * Exact outside diameters Ø D1 / Ø D2 (mm) Clamp Body.

Components: Dimensions / Order Codes Clamp Body. * 1st part of STAUFF Group 4. * Exact outside diameters Ø D1 / Ø D2 (mm) Clamp Body. Components: Dimensions / Order Codes Clamp Body Clamp Body Colour: Green Material code: PP 4 PP One clamp body is consisting of two clamp halves. 1st part of STAUFF 4 Exact outside diameters Ø D1 / Ø D2

More information

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor) The steel reinforced aluminium conductor consists of seven or more aluminium wires applied in concentric layers over a steel core made of one

More information

SECTION PIPE HANGERS AND SUPPORTS

SECTION PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

CATALOGUE. Metzerplas

CATALOGUE. Metzerplas CATALOGUE Metzerplas C E R T I F I C A T I O N 3 SP pipe is approved by standards institutes around the world Institute Certificate No. Product Standard Country IAPMO 4755 Pex-Al-Pex Composite pressure

More information

PSI Plastic Insulators System

PSI Plastic Insulators System Pipeline Accessories PSI Plastic Insulators System General Information Technical Data Selection Guide 1 PSI Plastic Insulators System Material Test Certificate PSI Plastic Insulators System General Information

More information

RDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F

RDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F Type Series Booklet 1387.5/2--10 RDLO / RDLO V Axially Split Volute Casing Pumps Fields of Application Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems,

More information

RUBBER BELLOWS TYPE 1A & 1S SERIES

RUBBER BELLOWS TYPE 1A & 1S SERIES RUBBER BELLOWS TYPE 1A & 1S SERIES Description: Vibracoustics Ltd Reiflexa Bellows are made from various elastomers reinforced with high tensile textile or steel cords to provide the flexible elements

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

Product Datasheet. Cable TV Junction Box (Page 4)

Product Datasheet. Cable TV Junction Box (Page 4) JUNCTION BOX Product Datasheet Junction Box Bolted Type (Page 2) Cable TV Box (Page ) Cable TV Junction Box (Page 4) Telephone Box (Page 5) Telephone Junction Box (Page 6) GRP Junction Box Enclosures are

More information

T!"#!$ %#&'#& ( T )*"+),&$ -.)/0 "12

T!#!$ %#&'#& ( T )*+),&$ -.)/0 12 www.karasus.com The elastic metal bellowed parts absorbing the heat induced expansion or changes in ambient temperatures are called expansion joints. If no measures are taken against changes in size of

More information

Road Tunnel Fire Protection. with Alvenius Piping Systems

Road Tunnel Fire Protection. with Alvenius Piping Systems Road Tunnel Fire Protection with Alvenius Piping Systems EN 2 Alvenius piping systems where top safety is paramount Alvenius supplies reliable and safe steel piping for fire protection in road tunnels.

More information

TML TML. Socketless cast iron waste water system for civil engineering applications. Product information

TML TML. Socketless cast iron waste water system for civil engineering applications. Product information TM TM waste water system for civil engineering applications Product information TM Product range, technical data TM waste water system for civil engineering applications TM product information Tough and

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description Side channel pumps PN 16 Self-priming centrifugal pumps SOH - SOHB Technical description Operating data Design Industries Media pumped: Nominal diameter: 1-1 1 /2 Flow rate: 0.3-7.5 m 3 /h Pump head: 5-155

More information

PRODUCT CATALOGUE EFFECTIVE FROM 1 ST JANUARY 2013 MULTI-LAYER PIPE & PRESS FITTING SYSTEM

PRODUCT CATALOGUE EFFECTIVE FROM 1 ST JANUARY 2013 MULTI-LAYER PIPE & PRESS FITTING SYSTEM PRODUCT CATALOGUE EFFECTIVE FROM 1 ST JANUARY 2013 MULTI-LAYER PIPE & PRESS FITTING SYSTEM PRESSTITE INTRODUCTION Introduction to Presstite Presstite Multilayer is a composite pipe system using the advantages

More information

BUTTERFLY VALVE WAFER TYPE of carbon steel ( ) series

BUTTERFLY VALVE WAFER TYPE of carbon steel ( ) series Operation WAFER TYPE of carbon steel 1100 (1000-100) series C ont R o L Operation Edition 0-0-009 Wafer type butterfly valve 1100 (1000 100) series is used in industrial pipelines for demanding on-off

More information

HAWLE-specification water

HAWLE-specification water water GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN GÜTEZEICHEN HAWLE - Epoxy Powder-Coating High quality corrosion

More information

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p.

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p. contents BUsHEs 140 Hexagon Bush p.5 NiPPlEs 144 octagon Nipple p.6 145 Hexagon Nipple p.6 PlUgs 146 Beaded Plug - solid p.7 147 Plain Plug - Hollow p.7 148 Plain Plug - solid p.7 149 countersunk Plug

More information