AC axial fan. sickled blades (S series) with guard grille for full nozzle
|
|
- Clara Murphy
- 5 years ago
- Views:
Transcription
1 SD-BH8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor SD-BH8- MD68-BC Phase ~ ~ Nominal voltage VAC Connection Y Y Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min Power input W 68 7 Current draw A.7. Max. back pressure Pa Max. ambient temperature C 5 7 Starting current A.6. ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations Item no Revision 65 Release --8 Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
2 SD-BH8- Technical features Mass Size Surface of rotor Material of blades Material of guard grille Number of blades 9 Direction of air flow Direction of rotation.6 kg mm Coated in black Sheet steel, coated in black Steel, phosphated and coated in black plastic "V" Type of protection IP Insulation class Counter-clockwise, seen on rotor "B" Humidity class F- Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig., TN system) Cable exit Protection class + 8 C - C Shaft horizontal or rotor on bottom; rotor on top on request Rotor-side S Ball bearing <.75 ma Lateral Product conforming to standard EN 65- Approval I (if protective earth is connected by customer) CCC; GOST Item no Revision 65 Release --8 Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
3 SD-BH8- Product drawing Connection line PVC, 7x crimped core-end sleeves Direction of air flow "V" Direction of rotation counterclockwise, seen on rotor Item no Revision 65 Release --8 Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
4 SD-BH8- Connection screen Note: Direction of rotation changes when two phases are reversed Δ Delta connection Y Star connection L black L blue L brown U black V blue W brown U green V white W yellow Item no Revision 65 Release --8 Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
5 SD-BH8- Charts: Air flow 5 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 5 6,85, ,75,7,65,6,55,5,5, pfs_e[in HO] Measurement: LU-698 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 9, ,,5 5,,5, 5 6 qv[m^/h] ,5. Measured values U V f Hz n min P e W I A qv m /h p fs Pa 6 89 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no Revision 65 Release --8 Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
6 SD-BH8- Charts: Air flow 6 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 5 6 7,85, ,75,7,65,6,55,5,5, pfs_e[in HO] Measurement: LU-698 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 9, ,,5 5,,5, qv[m^/h] ,5. Measured values U V f Hz n min P e W I A....5 qv m /h p fs Pa 6 96 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no Revision 65 Release --8 Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () Fax +9 () info@de.ebmpapst.com
AC axial fan. sickled blades (S series) with full square nozzle
WD5-GA-9 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. straight blades (A series) with full round nozzle
WD-CA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. forward curved, dual inlet with housing (flange)
DE-AM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. backward curved
RE8-CB8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series), single inlet Wall ring with guard grille
WE5-CO5-66 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA
S4D45-AP3- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court
More informationAC axial fan. sickled blades (S series) Wall ring with guard grille
W4E3-DN2-39 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County
More informationAC axial fan. sickled blades (S series) with guard grille for full nozzle
SE-P8-6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan - RadiCal
RE5-RB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. blades with special design (K series) with guard grille for full nozzle
SE6-EC-5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. backward curved
RE-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series)
AE5-AL6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone: +9()798/8- Fax: +9()798/8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor AE5-AL6- ME68-CF Phase ~ ~ Nominal voltage
More informationAC axial fan. sickled blades (S series)
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone: +9()798/8- Fax: +9()798/8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor ME68-CF Phase ~ ~ Nominal voltage V Frequency
More informationAC centrifugal module - RadiCal
KE5-RA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationAC centrifugal fan. forward curved, dual inlet with housing (without flange)
DE-DM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor DE-DM7- ME68-DF Phase ~ ~ Nominal voltage
More informationAC centrifugal fan. forward-curved, single-intake with housing (flange)
GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationAC centrifugal fan. forward-curved, dual-intake with housing (without flange)
DE-AM7-65 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationAC centrifugal fan. forward curved, dual inlet with housing (flange)
ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone: +49(0)7938/81-0 Fax: +49(0)7938/81-110 info1@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor D2E133-AM47-23 M2E068-DF Phase
More informationAC centrifugal fan with housing (small flange)
DE-HT- ebm-papst Mulfingen GmbH & Co. KG Bachmühle Mulfingen Phone: + - Fax: + - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor DE-HT- ME-EC Phase ~ ~ Nominal voltage [V] Frequency [Hz]
More informationEnergy-saving motors (ESM)
Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving
More informationAC axial fans S series, Ø 500
axial fans, Ø 500 Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic lades: Sheet aluminium Rotor: ncased in aluminium
More informationProduct Data Sheet DV5214 NU
The engineer's choice DV5214 NU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationProduct Data Sheet 632 NU-006
The engineer's choice 632 NU-006 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet ACi 4420 HHR
ACi 4420 HHR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5
More informationEnergy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch
Energy-saving axial fans A solution specifically designed for unit cooler applications. The engineer s choice 0-Position rotary switch New SG05 series designed for unit cooler applications EC axial fans
More informationListen to the difference. The AxiTop diffuser.
Listen to the difference. The AxiTop diffuser. The whispering power pack. The breakthrough for greater efficiency and less noise: our AxiTop diffuser provides a substantial improvement in efficiency and
More informationProduct Data Sheet 8412 NHU-519
The engineer's choice 8412 NHU-519 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet 8314 HR-197
The engineer's choice 8314 HR-197 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet 624 NR. The engineer's choice
Product Data Sheet 624 NR Product Data Sheet 624 NR The engineer's choice Product Data Sheet 624 NR 624 NR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data...
More informationProduct Data Sheet ACi 4420 MLR
ACi 4420 MLR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5
More informationProduct Data Sheet 4118 N/ The engineer's choice
The engineer's choice 4118 N/12-190 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical
More informationProduct Data Sheet 3214 JH3-195
3214 JH3-195 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 6
More informationProduct Data Sheet 3214 J/2H3F-191
The engineer's choice 3214 J/2H3F-191 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet 4184 N/17X. The engineer's choice
Product Data Sheet 4184 N/17X The engineer's choice 4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical
More informationAC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.
4 AC Fans AC Fans Overview 7 AC Axial Fans 8 AC Radial Fans 38 AC Radial Fans AC Axial Fans AC Fans ACmaxx Axial Fans Technology DC Axial Fans Specials DC Radial Fans 5 Accessories AC Fans Technical Informations
More informationProduct Data Sheet 4184 NXHH
The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More information4314/17T. Product Data Sheet INDEX
4314/17T INDEX 1 General... 2 2 Mechanics... 2 2.1 General... 2 2.2 Connections... 2 3 Operating Data... 2 3.1 Operating Data - Electrical Interface - Input... 3 3.2 Electrical Operating Data... 4 3.3
More informationProduct Data Sheet 8412 N/ The engineer's choice
The engineer's choice 8412 N/12-252 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output...
More informationAC axial fans, AC diagonal fans
fans, C diagonal fans Technology ccessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans series fans fans Ø 130 - Ø 250 14 C diagonal fans Ø 208 20 13 Contacts fans Ø 130
More informationMotors- Basic principles. Expertise, performance, innovation
Motors- Basic principles Expertise, performance, innovation As a leading supplier of ventilation and drive engineering technology, ebm-papst is a highly respected engineering partner in many industries.
More informationRadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000
RadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000 A coherent concept. RadiPac stands for Realistic performance specifications, as the performance data of the entire fan is continuously
More informationAXIAL FAN WITH EXTERNAL ROTOR MOTOR
XIL FN ITH EXTERNL ROTOR MOTOR 1. YF series axial fans are external rotor motors. These motors have characteristics of compact structure, convenient installation and high efficiency etc. 2. YF series external
More informationProduct Data Sheet 614 N/2HH-169 The engineer's choice
The engineer's choice 614 N/2HH-169 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical
More informationProduct Data Sheet 4184 NGX
The engineer's choice 4184 NGX INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationproduct specification
4414 ML Customer specification: No Version: 1.0 Created: 16.09.2011 INDEX 1 General... 2 2 Mechanics... 2 2.1 GENERAL... 2 2.2 MOTOR... 2 2.3 CONNECTIONS... 3 3 Operating Data... 4 3.1 OPERATING DATA -
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationProduct Data Sheet 4414/2H
The engineer's choice 4414/2H INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationIBExU Institut für Sicherheitstechnik GmbH
[1] EC-TYPE EXAMINATION CERTIICATE according to Directive 94/9/EC, Annex 111 [2] Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres, Directive 94/9/EC [3] EC-Type Examination
More informationProduct Data Sheet 4184 NXHH
The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationProduct Data Sheet 8414 NGH
The engineer's choice 8414 NGH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas
More informationDigital display Pressure range ON/OFF output Linear output Model
Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be
More informationProduct Data Sheet DV4118 N
The engineer's choice DV4118 N INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationCENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue
CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey
More informationTechnical Specifications
APPENDIXA Environmental and for the Switch, page A-1 Environmental and for the Power Supply and Fan Modules, page A-5 Environmental and for the Switch Table A-1 Environmental Ranges for the Switch Environmental
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:
More informationMegaBox Product-specific information
MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationPressure Transmitter JUMO dtrans p30 Type
Data Sheet 40466 Page 1/6 Pressure Transmitter JUMO dtrans p0 Type 40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The
More informationDATA SHEET. 152 RMH Aluminum electrolytic capacitors Radial Miniature, High voltage. BCcomponents
DATA SHEET Supersedes data of 18th January 2000 File under BCcomponents, BC01 2000 Apr 07 FEATURES Polarized aluminum electrolytic capacitors, non-solid electrolyte Radial leads, cylindrical aluminum case,
More information- 1 - Tel.: Fax: Battery charging units BLG2024 and BLG3524
Product description - 1 - Tel.: 49 2162 40025 Fax: 49 2162 40035 info@dsl-electronic.de www.dsl-electronic.de DSL electronic GmbH Battery charging units BLG2024 and BLG3524 Wide input voltage range 90...132
More informationBrushless internal rotor motors ECI series. Drive solutions Industrial drive engineering
Brushless internal rotor motors ECI series Drive solutions Industrial drive engineering Modular drive systems. Motors with integrated logic and power electronics optional gearhead, encoder and brake. Contents.
More informationLenze. Drives with worm gearboxes 52.
6 887 Lenze Drives with worm gearboxes 5. Lenze Drive Systems GmbH, Postfach 0 5, D-76 Hameln, Site: Groß Berkel, Hans-Lenze-Straße, D-855 Aerzen, Phone ++9 (0) 55 8-0, Telefax ++9 (0) 55 8- E-Mail: Lenze@Lenze.de
More informationGeneral_technical_data Series
Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The
More informationJUMO MIDAS S05 Pressure transmitter Type
Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationVoltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]
Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge
More informationThe new fan generation S-Force
The new fan generation S-Force S-Force The Ultimate Performer The strongest team in the league The S-Force series is composed of five smaller series with sizes from 80 to 172 mm. Each is the world champion
More informationN, N4. End-Suction Centrifugal Pumps standardized EN 733
, Construction Single-stage end-suction centrifugal pumps, with bearing bracket. ominal duty points and main dimensions in accordance with E 7. Back Pull-Out construction, for simple and quick dismantling
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationData sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m
Data sheet Item no.: 2600 Page: 1 / 5 Operating data Requested flow rate 40.00 m ³/h Actual flow rate 40.00 m ³/h Requested developed head 68.00 m Actual developed head 68.00 m Pumped medium Water Efficiency
More informationData sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.
Data sheet Item no.: 1900 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 72.19 m ³/h Operating data determined for maximum inlet pressure Actual developed head 70.26 m Clean water Efficiency
More informationThermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar
Pressure Transmitter Type FM40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The measuring device for the transmitter
More informationfranklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps
franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering
More informationThree-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U
Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.
More informationKirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser
Kirby WRC Remote Condenser With HyBlade EC Fans and AxiTop Diffuser 114kW 651kW Product Overview The Kirby WRC Remote Condenser is a market leading and energy efficient remote condenser specifically designed
More informationILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox
Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Product availability : Stock - Normally stocked in distribution facility Price* : 840.00 USD Main Range
More informationContents. Identification
Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions
More informationVolute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML
Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive Series CNH-ML Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service
More informationGeneral_technical_data Series
Actuator with snap-action switching element Switching system Self-cleaning, double-break snap-action switching system with contact opening width 2 x 0.5 mm (switch with small contact opening width as per
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information2-position electric actuators with Ball valves VBZ ½...11/4
4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230
More informationILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1
Characteristics brushless dc motor 24..48V- EtherNet/IP interface - L = 174 mm- 18:1 Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number
More informationConditioning Module Reservoir Extraction CM-RE
Conditioning Module Reservoir Extraction CM-RE Description The ConditioningModule Reservoir Extraction CM-RE is designed as an accessory to the CS ContaminationSensors and the FCU FluidControl Units. The
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationExplosion and flame-proof cast iron electric motors
Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting
More informationIN-LINE CENTRIFUGAL DUCT FANS VT Series
IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationL1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel
Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.
More informationAXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure
Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the
More informationData sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationAluminum Capacitors Power High Ripple Current Screw Terminals
101/102 PHR-ST Aluminum Capacitors FEATURES ST STB Fig.1 Component outline Polarized aluminum electrolytic capacitors, non-solid electrolyte Large types, cylindrical aluminum case, insulated with a blue
More informationStandard-efficiency gas heating. Innovation is our tradition.
Standard-efficiency gas heating. Innovation is our tradition. About ebm-papst. As a leader in technologies for ventilation and drive engineering, ebm-papst is in demand as an engineering partner in many
More informationDifferential Pressure Sensors
1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output
More information400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet
THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for
More informationPressure Transmitter JUMO dtrans p30 Type
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More information