AC axial fan. straight blades (A series) with full round nozzle
|
|
- Jeremy Gray
- 6 years ago
- Views:
Transcription
1 WD-CA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General partner: Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor WD-CA- MD68-CF Phase ~ ~ ~ ~ Nominal voltage VAC Connection Δ Δ Y Y Frequency Hz Type of data definition fa fa fa fa Valid for approval / standard CE CE CE CE Speed min Power input W Current draw A Max. back pressure Pa Max. ambient temperature C ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
2 WD-CA- Technical features Mass Size Surface of rotor Material of impeller Material of wall ring Material of guard grille Number of blades 5 Direction of air flow Direction of rotation.6 kg mm Coated in black Sheet steel, coated in black Sheet steel, galvanised Steel, phosphated and coated in black plastic "A" Clockwise, seen on rotor Type of protection IP ; Depending on installation and position as per EN 6-5 Insulation class "B" Humidity class F- Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Leakage current Cable exit Protection class Product conforming to standard Approval + 8 C - C Shaft horizontal or rotor on top; rotor on bottom on request Rotor-side S Ball bearing <.75 ma Lateral I (if protective earth is connected by customer) EN 65- CCC Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
3 WD-CA- Product drawing Connection line PVC 7G.5 mm², 7x brass lead tips crimped Direction of air flow "A" Direction of rotation counter-clockwise, seen on rotor Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
4 WD-CA- Connection screen Note: Direction of rotation changes when two phases are reversed Δ Delta connection Y Star connection L black L blue L brown U black V blue W brown U green V white W yellow PE green/yellow Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
5 WD-CA- Charts: Air flow 5 Hz Druck p sf[pa]für Rho=,kg/m^ 5 5 qv[cfm] , qv[m^/h] ,,5,,5,95,9,85,8,75,7,65,6,55,5,5,,5,,5,,5,, psf_e[in HO] Measurement: LU-5856 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U f n P e I qv p sf V Hz min - W A m /h Pa Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
6 WD-CA- Charts: Air flow 6 Hz Druck p sf[pa]für Rho=,kg/m^ qv[cfm] qv[m^/h] ,55,5,5,,5,,5,,5,,5,95,9,85,8,75,7,65,6,55,5,5,,5,,5,,5,,5 psf_e[in HO] Measurement: LU-5857 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U f n P e I qv p sf V Hz min - W A m /h Pa Item no.: Revision: 798 Print-out: --6 Y. Uhlmann (VM-TDO) Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone Fax info@de.ebmpapst.com
AC centrifugal fan. backward curved
RE-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series) with guard grille for full nozzle
SD-BH8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series) with full square nozzle
WD5-GA-9 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. forward curved, dual inlet with housing (flange)
DE-AM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. backward curved
RE8-CB8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series)
AE5-AL6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone: +9()798/8- Fax: +9()798/8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor AE5-AL6- ME68-CF Phase ~ ~ Nominal voltage
More informationAC axial fan. sickled blades (S series) Wall ring with guard grille
W4E3-DN2-39 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County
More informationAC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA
S4D45-AP3- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court
More informationAC centrifugal fan. forward curved, dual inlet with housing (without flange)
DE-DM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor DE-DM7- ME68-DF Phase ~ ~ Nominal voltage
More informationAC axial fan. sickled blades (S series)
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone: +9()798/8- Fax: +9()798/8- info@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor ME68-CF Phase ~ ~ Nominal voltage V Frequency
More informationAC axial fan. sickled blades (S series), single inlet Wall ring with guard grille
WE5-CO5-66 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. blades with special design (K series) with guard grille for full nozzle
SE6-EC-5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC axial fan. sickled blades (S series) with guard grille for full nozzle
SE-P8-6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan - RadiCal
RE5-RB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan. forward curved, dual inlet with housing (flange)
ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone: +49(0)7938/81-0 Fax: +49(0)7938/81-110 info1@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor D2E133-AM47-23 M2E068-DF Phase
More informationAC centrifugal module - RadiCal
KE5-RA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationAC centrifugal fan with housing (small flange)
DE-HT- ebm-papst Mulfingen GmbH & Co. KG Bachmühle Mulfingen Phone: + - Fax: + - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor DE-HT- ME-EC Phase ~ ~ Nominal voltage [V] Frequency [Hz]
More informationAC centrifugal fan. forward-curved, single-intake with housing (flange)
GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationAC centrifugal fan. forward-curved, dual-intake with housing (without flange)
DE-AM7-65 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationEnergy-saving motors (ESM)
Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving
More informationAC axial fans S series, Ø 500
axial fans, Ø 500 Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic lades: Sheet aluminium Rotor: ncased in aluminium
More informationAC axial fans, AC diagonal fans
fans, C diagonal fans Technology ccessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans series fans fans Ø 130 - Ø 250 14 C diagonal fans Ø 208 20 13 Contacts fans Ø 130
More informationProduct Data Sheet 632 NU-006
The engineer's choice 632 NU-006 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet 8314 HR-197
The engineer's choice 8314 HR-197 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationProduct Data Sheet ACi 4420 HHR
ACi 4420 HHR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5
More informationListen to the difference. The AxiTop diffuser.
Listen to the difference. The AxiTop diffuser. The whispering power pack. The breakthrough for greater efficiency and less noise: our AxiTop diffuser provides a substantial improvement in efficiency and
More informationEnergy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch
Energy-saving axial fans A solution specifically designed for unit cooler applications. The engineer s choice 0-Position rotary switch New SG05 series designed for unit cooler applications EC axial fans
More informationProduct Data Sheet 624 NR. The engineer's choice
Product Data Sheet 624 NR Product Data Sheet 624 NR The engineer's choice Product Data Sheet 624 NR 624 NR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data...
More informationProduct Data Sheet ACi 4420 MLR
ACi 4420 MLR INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 4 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 5
More informationProduct Data Sheet DV5214 NU
The engineer's choice DV5214 NU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationProduct Data Sheet 3214 J/2H3F-191
The engineer's choice 3214 J/2H3F-191 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationAC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.
4 AC Fans AC Fans Overview 7 AC Axial Fans 8 AC Radial Fans 38 AC Radial Fans AC Axial Fans AC Fans ACmaxx Axial Fans Technology DC Axial Fans Specials DC Radial Fans 5 Accessories AC Fans Technical Informations
More informationProduct Data Sheet 4118 N/ The engineer's choice
The engineer's choice 4118 N/12-190 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical
More informationProduct Data Sheet 8412 NHU-519
The engineer's choice 8412 NHU-519 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More information4314/17T. Product Data Sheet INDEX
4314/17T INDEX 1 General... 2 2 Mechanics... 2 2.1 General... 2 2.2 Connections... 2 3 Operating Data... 2 3.1 Operating Data - Electrical Interface - Input... 3 3.2 Electrical Operating Data... 4 3.3
More informationProduct Data Sheet 3214 JH3-195
3214 JH3-195 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 6
More informationAXIAL FAN WITH EXTERNAL ROTOR MOTOR
XIL FN ITH EXTERNL ROTOR MOTOR 1. YF series axial fans are external rotor motors. These motors have characteristics of compact structure, convenient installation and high efficiency etc. 2. YF series external
More informationMotors- Basic principles. Expertise, performance, innovation
Motors- Basic principles Expertise, performance, innovation As a leading supplier of ventilation and drive engineering technology, ebm-papst is a highly respected engineering partner in many industries.
More informationProduct Data Sheet 4184 N/17X. The engineer's choice
Product Data Sheet 4184 N/17X The engineer's choice 4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical
More informationProduct Data Sheet 4184 NXHH
The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationproduct specification
4414 ML Customer specification: No Version: 1.0 Created: 16.09.2011 INDEX 1 General... 2 2 Mechanics... 2 2.1 GENERAL... 2 2.2 MOTOR... 2 2.3 CONNECTIONS... 3 3 Operating Data... 4 3.1 OPERATING DATA -
More informationProduct Data Sheet 4414/2H
The engineer's choice 4414/2H INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationIBExU Institut für Sicherheitstechnik GmbH
[1] EC-TYPE EXAMINATION CERTIICATE according to Directive 94/9/EC, Annex 111 [2] Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres, Directive 94/9/EC [3] EC-Type Examination
More informationCENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue
CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey
More informationProduct Data Sheet 4184 NXHH
The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationRadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000
RadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000 A coherent concept. RadiPac stands for Realistic performance specifications, as the performance data of the entire fan is continuously
More informationProduct Data Sheet 614 N/2HH-169 The engineer's choice
The engineer's choice 614 N/2HH-169 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical
More informationProduct Data Sheet 4184 NGX
The engineer's choice 4184 NGX INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationProduct Data Sheet 8412 N/ The engineer's choice
The engineer's choice 8412 N/12-252 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output...
More informationIN-LINE CENTRIFUGAL DUCT FANS VT Series
IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationSelection Chart. SC Series 6 inch (150mm) Submersible Borehole Pumps PERFORMANCE DATA SC65 SC50 SC30 SC18 TOTAL HEAD FEET Q (LITRES PER MINUTE)
PERFORMANCE DATA Selection Chart TOTAL HEAD FEET 450 400 350 300 250 200 150 100 50 0 GALLONS PER MINUTE 0 50 100 150 200 250 300 SC18 SC30 SC50 SC65 0 200 400 600 800 1000 1200 1400 Q (LITRES PER MINUTE)
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationVoltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]
Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge
More informationProduct Data Sheet DV4118 N
The engineer's choice DV4118 N INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationMultifunctional 400ºC/2h and 300ºC/2h roof fans
HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.
More informationThe new fan generation S-Force
The new fan generation S-Force S-Force The Ultimate Performer The strongest team in the league The S-Force series is composed of five smaller series with sizes from 80 to 172 mm. Each is the world champion
More informationMultifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows
HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More informationBrushless internal rotor motors ECI series. Drive solutions Industrial drive engineering
Brushless internal rotor motors ECI series Drive solutions Industrial drive engineering Modular drive systems. Motors with integrated logic and power electronics optional gearhead, encoder and brake. Contents.
More informationVolute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML
Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive Series CNH-ML Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service
More informationConditioning Module Reservoir Extraction CM-RE
Conditioning Module Reservoir Extraction CM-RE Description The ConditioningModule Reservoir Extraction CM-RE is designed as an accessory to the CS ContaminationSensors and the FCU FluidControl Units. The
More informationCENTRIFUGAL IN-LINE FANS VENT Series
Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.
More informationVKA/VKAS. Circular duct fans CIRCULAR DUCT FANS
Circular duct fans VKA Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. Are mounted into a system of round air ducts. Can be installed in any position.
More informationMegaBox Product-specific information
MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions
More informationTD-SILENT Series (160 to 1000 models)
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (1 to models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-3, TD-, TD-8 and
More information400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet
THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More information400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity
400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,
More informationBRIZA 22 HYBRID HEATING & COOLING
BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe
More informationLSES high efficiency three-phase asynchronous motors. General information
Efficiency class IE2 General information Totally enclosed three-phase saving asynchronous motors, series, according to IEC 60034, 60038, 60072 ; 0.75 to 200 kw, frame size 80 to 315 mm. Single speed: 2,4
More informationPlate mounted axial flow fans HXBR / HXTR Series
Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester
More informationN, N4. End-Suction Centrifugal Pumps standardized EN 733
, Construction Single-stage end-suction centrifugal pumps, with bearing bracket. ominal duty points and main dimensions in accordance with E 7. Back Pull-Out construction, for simple and quick dismantling
More informationfranklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps
franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering
More informationVORTICENT C E RANGE Centrifugal fans
NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,
More informationContents. Identification
Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM
More informationVKA/VKAS. Circular duct fans CIRCULAR DUCT FANS
Circular duct fans VKA Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. Are mounted into a system of round air ducts. Can be installed in any position.
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:
More informationProduct Data Sheet 8414 NGH
The engineer's choice 8414 NGH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationKAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels
KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to
More informationNDR Series Rotor Pack
efore using the product, please check the DR Series Rotor ack Features Low noise chieves a noise level of no greater than 0 d () and there is no need to worry about hydraulic noise even at factories in
More informationCMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS
CENTRIFUGAL PUMPS CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART 202 PERFORMANCE CHART CMA 0.50 203 PERFORMANCE CHART CMA 0.75 204 PERFORMANCE CHART CMA 0.80 205 PERFORMANCE CHART
More informationDBC-1 DEIF Battery Charger
DBC-1 DEIF Battery Charger INSTALLATION INSTRUCTIONS 12/24 V-5/10 A-115/230 V High MTBF > 60,000 h at 70 C Temp. range -25 C to +70 C Overvoltage protected Boost/equalisation functionality Failure alarm
More informationKirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser
Kirby WRC Remote Condenser With HyBlade EC Fans and AxiTop Diffuser 114kW 651kW Product Overview The Kirby WRC Remote Condenser is a market leading and energy efficient remote condenser specifically designed
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationSF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100
SPECIFICATIONS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CHART R10 204 PERFORMANCE CHART R13 205 PERFORMANCE CHART S25 206 PERFORMANCE
More informationTechnical Specifications
APPENDIXA Environmental and for the Switch, page A-1 Environmental and for the Power Supply and Fan Modules, page A-5 Environmental and for the Switch Table A-1 Environmental Ranges for the Switch Environmental
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationQuick guide. Plug-in fans GPPM with FC101_106 August 2014
Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors
More information2-position electric actuators with Ball valves VBZ ½...11/4
4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230
More informationSV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7
SV-UNOBOX FAN Mutassim Al-Daour factory for Metal Industries SV-7 INDEX INTRODUCTION PERFORMANCE GRAPHS TECHNICAL DATA DIMENSIONS ACOUSTIC DATA - SOUND PRESSURE LEVEL ELECTRICAL DETAILS pages - - 7 8 9
More informationStandard-efficiency gas heating. Innovation is our tradition.
Standard-efficiency gas heating. Innovation is our tradition. About ebm-papst. As a leader in technologies for ventilation and drive engineering, ebm-papst is in demand as an engineering partner in many
More informationBPF. Centrifugal Plug Fans
BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged
More information