UTP-10 Universal Tachograph Programmer & Tester QUICK START v.1.01
|
|
- Meghan Dawson
- 5 years ago
- Views:
Transcription
1 UTP-10 Universal Tachograph Programmer & Tester QUICK START v.1.01 I. Device description Powering and AMT connector ( photo sensor ). 2. Signal connector. 3. LCD display. 4. Functional keys F1 F4 5. LEDs signalizing accumulator status. 6. Cursor keys 7, 4, 8, 9 / alpha-numeric 7. Alpha-numeric buttons. 8. Turn on-off / leave / cancel button. II. Basic operations 1. Turning the device on One turns the device on by pressing the C button, and turns it off by pressing and holding the C button After turning the UTP-10 tester on, such information as the type of device and its firmware version as well as the current date and local time will be displayed on the screen. The UTP-10 will go to menu no. 1 after the autotest is complete. UTP-10 can be powered in two ways: - by 4 R6 AA 1.2V NiMH or NiCd accumulators or any four R6 1.5V AA batteries - by the power supply with the 5-30V input Voltage; 0.1A DC via the F cable 2. Working with UTP-10 tester 2.1 Keyboard, screen and menu The membrane keyboard consists of twenty buttons. The numeric 0,1,2..9 buttons allow to enter digital and alphanumeric values. The. * button allow to enter special characters such as - & /... F1-F4 buttons are used to select the function displayed on the screen: - directly over a given button or - described on the screen in the following form: F1 xxxxx xxx F2 yyyyy yyy... Icon and on the display corresponds to cursor buttons on the keyboard. If these characters are displayed on the screen, it means that the cursor buttons are active and allow to scroll the menu or change a parameter. The M # button enables a quick move to the memory service M#1 M#8 for analogue tachographs and M#1 M#16 for digital tachographs. By pressing the (ENTER) button we enter the edit mode as well as save the edited parameters. The screen of the device is a backlit LCD display, 4 lines 16 alpha-numeric characters each. The UTP-10 menu consists of 4 main menus (Menu-1 Digital tachographs, Menu-2 Programmable tachographs, Menu-3 analogue tachographs, Menu-4 UTP-10 settings). 2.2 First start-up Setting the parameters All parameters settings of the UTP-10 are being done in the Menu 4 These parameters should be set depending on the workshop (i.e.: name of the workshop, w measuring method), user liking (i.e.: pressing buttons signalization), adjusting to the region (i.e.: date-time, zone, summer-winter time) One needs to set the following parameters (see the menu tree): - wdi w choose the measurement method - wdi d set the length of the measuring track on which the measurements will be taken - wdi i select the number of converter impulses used for calculating the w coefficient for vehicles equipped with mechanical tachographs such as UTP-10 quick start v1.01 1
2 - wdi Lm select the method of calculating the average wheels circumference (does not concern the wdi-w option, when the rolling roads method has been chosen) - Tp program the user tests for analogue tachographs, according to own procedures or those used in a given country (availability of the Tp option depends on the region/country that the UTP-10 tester has been designed for) - SvN enter the name of the workshop 5 lines with 16 characters each (it will appear on printed labels and reports) - sys UTC set the current date and time - sys con set the proper contrast and backlight of the display. - sys ES F1 setting option UTP auto-off F2 setting option turning buttons sound on / off WARNING! The sys-con and sys-es options will influence the speed of discharging the accumulators and therefore the UTP-10 operating time 2.3 Average wheels circumference calculating method If one selects F3 Rolmatt or F4 Actia in the menu 4 wdi menu, then the average wheel circumference in the calibration for digital tachographs menu can be entered only by rolling the wheel method. However if one selects F1 wi (whole impulses) or F2 wii (fraction impulses-this method is more accurate than wl) or F4 HRR (option) in the menu 4 wdi w menu, then the average wheel circumference can be entered by one of the methods specified in the menu 4 wdi Lm menu. These are as follows: - F1 ØL = L end L strt rolling the wheel on gauge ribbon method - F2 ØL = 2*pi*r measuring method of entering measured wheels radius - F3 ØL = manual entering average wheels circumference manually 3. Operating on digital tachograph WARNING! Familiarize yourself with the binding regulations in your country regarding details and the order of activities performed while inspecting-calibrating digital tachographs. 3.1 Exemplary inspection and calibration of the digital tachograph using the UTP-10 tester. Select the tachograph that you want to make the calibration for using the F1-F4 buttons in the menu 1. Making tachograph tests - press F3 - tst - One needs to make all tachograph tests (keyboard, display, printer...) and confirm or decline the correctness of the implementation. - Card readers test should be done by shifting the workshop card and entering PIN. - The 1000m test is done on a rolling roads and therefore does not concern workshops that measure the w coefficient on the measuring track. - If all tests results are positive one can move to the calibration phase (phase order to be established). Calibrating tachograph - press F1 cal - for SmarTach tachograph select: F1 full calibration with pairing converter or F2 only pairing converter. - Time info is the first screen of the calibration it is the date and time that is set in the tachograph. WARNING! 1. Confirming the values of individual parameters in the cal menu does not mean saving them in the tachograph they are stored only in the UTP-10 memory. Saving all parameters is done after selecting F1-YES option in the last step of calibration. In that moment the date and time is also transferred from the UTP-10 to tachograph. 2. None o the parameters with the info in its name can be edited. In order to move to next parameters one should use the up/down cursors - Second screen allows to set three parameters: - RMS setting a country where the calibration has been done, - CP Code Page it should always be 1 which is the Latin set of characters. - VRN Vehicle registration number. - VIN is the next calibration parameter, it always consists of 17 alphanumeric characters. - Odometer The next parameter is the odometer. It can be edited and saved by pressing the Enter button and entering any value. - Speed author. The next parameter is the Max speed which is setting the speed that the tachograph will inform the driver or the vehicle computer about its exceeding. - Tire size Tires size one needs to enter the size of tires. - Tire circumf. Wheels circumference (see also point 2.3). - w constant - One can enter it manually or it will be saved automatically after performing the w measurement. In order to move to the measuring menu, one needs to press the F1 button. After the measurement is done we leave the function by pressing the C button and the screen with constant w is displayed again where the cursor is flashing under its value. All one needs to do is press the ENTER button in order to overwrite the old value by the w measured value. UTP-10 quick start v1.01 2
3 - k const. info is an information about the constant k value. For the programmable tachographs, its always w=k, - Next cal. date. According to law, the calibration should be done every 24 months. After pressing the Enter button, two years in advance date will be displayed. Pressing the Enter button again confirms that date. - MS pairing. There is no need to pair the converter if it hasn t been exchanged or the tachographs wasn t replaced. - Save calibr. F1 -YES / F4 - NO. Function std - press F2 std Select F3 DTC Service in order to read and delete all errors. If for some reason one of the errors cannot be deleted, one should check the error table what does a given error mean, remove the cause of that error and try to delete the errors from tachograph again. The DTC (Device Trouble Code) errors description can be found in ISO document which is the seventh part of the document. It can be purchased on the following website: The report from making tests can be printed or sent to the Tachomatt Red on PC. 3.2 Printouts One can print measuring labels directly from UTP-10 to tachograph using the thermo-transfer printer. One needs to use the P1U cable. It is also possible to print the calibration report on the dot-matrix printer. Ask your distributor about the details or the MATT sales department. 4. Additional information WARRANTY The manufacturer grants a 12-months warranty period for the device, starting from the date of its purchase. Do not dispose the device to the trash! Used devices should be disposed at the point of electrical and electronic equipment waste collection in your place of residence. The manufacturer hereby declares that the UTP-10 device complies with the requirements of the 89/336/EEC (EMC) regulation providing it is used according to the instruction manual. The relevant declaration is available on the manufacturer s webpage. UTP-10 quick start v1.01 3
4 III. Menu tree* MENU 1 Digital Tacho F1 - ACTIA SmarTach F1 - cal F1- Full calibr. Time info F4 diag** F1 System param. F1 General CAN/A2 bklight F2- Pairing only RMS & VRN D6 speed detec. VIN Pwr save T-out Odometer Act.@ ing.off Speed author Act.@ ing.on Tyre size Compon. ident. Tyre circumf. w constant F1 w factor test F2 Add. engine Use engine reg. k const. info Next cal. date Save calibr. Nb Limits histo Histo limit val Engin config. Engine factor F2 - std F1 - Parameters Reset heartbeat Loc.time offset F3 Add. speed Use speed reg. Trip distance Nb Limits histo Shaft imp/rev Histo limit val Install. date Registr. Date F4 Add. D1/D2 D1/D2 Config. CAN-TC01 repet. CAN-TC01 prior. Teeth Number Date/Time/Zone Lang. from card Default lang. Tripmeter reset F2 IHM parameter Minut.incr.step Summ./Win.Times Days incr.step Char.incr.step F2 - Information Manufact. date Disp.speed unit Serial No Disp. contrast Syst.Supp HW Nr Loc. time offset Sys.Supp HW Ver State Timeout Software No Keyb.Timeout Software ver. Buzz. for keyb. Calib. date Buzz. for warn. O/p shaft spd Oversp. Prewarn. Type appr.nr. Overs.Prew.Time Service delay tachograph Bklight Thresh. F3 tst F3 MS parameter Max. Auth.Errors Max Comm.Errors F3 DTC service Max MS Prolems F1 printouts F1 rep Coeff1 Imp.Mar. F2 Lbl Coeff2 Imp.Mar. Max Imp.Verif. F2 mem. PC Memory Loc.Addr F3 mem. clear Inst.Err.Thresh Max Ins.Err.Cnt Periodic insp. clock test F4 Information MS OS Identif LCD nr 1 LCD nr 2 printer test keyboard test SW integrity Card reader 1 Card reader m test Speed simul.tv MS SC Identif HW config. MS SW Ver. Nr Boot SW Ver. Nr CSP SW Ver. Nr MS Serial Nr MS Approval Nr Activat. status Tacho prod. Nr * not all the functions are available in the firmware 4.XX version. ** functions available for Actia service UTP-10 quick start v1.01 4
5 F2 Siemens 1381 F4 SE 5000 F1 cal Time info F1 cal Time info RMS & VRN VIN Odometer Speed author. Tyre size Tyre circumf. RMS & VRN VIN Odometer Speed author. Tyre size Tyre circumf. w constant F1 w factor test w constant F1 w factor test k const. info Next cal. date MS pairing Save calibr. k const. info Next cal. date MS pairing Save calibr. F2 - std F1 - Parameters Reset heartbeat F2 - std F1 - Parameters Reset heartbeat Loc. time offset Trip distance Shaft imp/rev Loc. time offset Trip distance Shaft imp/rev Install. date Install. date Registr. Date Registr. date CAN-TC01 repet. CAN-TC01 repet. CAN-TC01 prior. CAN-TC01 prior. * Teeth Number * Teeth Number * CAN/A2 bklight * CAN/A2 bklight * Pwr off period * D6 pin function * rpm profile * Speerom.factor * v profile * Rezolut. input * Eng. spd source * kn factor * kn factor * Ing. off * Ing. on * D7 k-line * D8 serial out * CAN on/off * D1/D2 Config. F2 - Informations F3 DTC service Manufact. date Serial No Syst.Supp HW Nr F2 - Informations Manufact. date Sys.Supp HW Ver Serial No Software No Syst.Supp HW Nr Software ver. Sys.Supp HW Ver Calib. date Software No O/p shaft spd Software ver. Type appr.nr. Service delay tachograph V Measur. Range Printer Variant B7 Recognise CAN Variant F3 Serwis DTC Calib. date O/p shaft spd Type appr.nr Service delay tachograph V Measur. Range Activat. status F1 printouts F1 - rep F1 printouts F1 - rep F2 mem. PC F2 - Lbl F2 mem. PC F2 - Lbl F3 mem. clear F3 mem clear F3 tst Periodic insp. F3 tst Periodic insp. Clock test Clock test LCD LCD printer test printer test keyboard test keyboard test Card reader 1 Card reader 1 Card reader 2 Card reader m test Speed simul.tv 1000m test Speed simul.tv * functions available as an option UTP-10 quick start v1.01 5
6 F3 EFAS F1 - cal Time info F4 xtra* Tripmeter reset RMS & VRN VIN Odometer Speed author. Tyre size Tyre circumf. LCD dist. unit LCD date format CAN/A2 bklight Auto Dayl. sav. Revolut. input Kn factor w constant w factor test Rpm profile k const. info Next cal. date MS pairing Save calibr. v profile Oversp.Prewarn. Owers. Prew.Time Language change ign.off F2 - std F1 - Parameters Reset heartbeat ign. On Loc. time offset Print loc. Time Trip distance Ext. ser.if cfg Shaft imp/rev Remote downl. Install. date CAN A config. Registr. Date CAN A protocol CAN-TC01 repet. CAN A diag.prot CAN-TC01 prior. CAN C config. F2 - Informations Teeth Number Manufact. Date Serial No Syst.Supp HW Nr Sys.Supp HW Ver Software No Software ver. Calib. date O/p shaft spd Type appr.nr. Service delay tachograph V Measur. Range System supplier Calib. Equip. SN Calib. Equip. SW CAN C sync. jump CAN C smp. point F3 DTC service F1 printouts F1 - rep F2 mem. PC F3 mem. clear F2 - Lbl F3 tst Periodic insp. clock test LCD nr 1 LCD nr 2 Printer test Keyboard test Hardware test Card reader 1 Card reader m test Power supply I/O signals Engine speed Buzzer and LED Speed simul.tv * menu available as an option UTP-10 quick start v1.01 6
7 MENU 2 Programmable tacho F4 VR 2400 F1 - Parameters F1 k-factor F F1 - Parameters F1 k-factor F2 Odometer F2 Odometer F3 Date & time F3 Overspeed F4 mile/km F1 Overspeed F2 - Tests F1 w-fact.meas. F2 Sender type F2 k factor F3 rpm F3 Tachogr.test F4 Clock x 10 F1 CAN bus F3 - Informations F1 Install.date F2 4th Chart Tr. F2 Calibr.date F3 Other param. F1 D6 pin funct. F3 Service No F2 speedom.fact F4 Add. text F3 Service delay F F1 - Parameters F1 - k-factor F1 ign. rec. F2 -Testy F2 Odometer F2 Data norm. F3 Date & time F3 RES.Hbeat F1 - summer/winter F1 ratio F2 Service delay F2 d.ax.= F3 CAN bus type F1 Shaft factor F2 kn constant F3 Service No F1 w-fact.meas. F2 Clock test F3 Tachogr.test F2 - Testy F1 w-factor test F4 Sender.pair F2 Clock test F3 Tachogr.test F3 - Informations F1 Read DTC F2 VIN F1 Sender.pair F3 tachogr.date F2 Reset tach F1 - ki F1 Install.date F2 kn F2 Calibr.date F3 EGK-100 F3 Clock test F3 Tacho code F3 - Informations F1 Read DTC F2 VIN F1 ki F3 tachogr.data F2 n2 F3 n3 MENU 3 - Analog tacho F1 - tst F2 - Pt w-factor test k-factor test Clock test Speed simulator Odometer test Rev. counter Motion sensor F1 T1 F2 T2 F3 T3 F4 T4 F3 - aux F F2-028 UTP-10 quick start v1.01 7
8 MENU 4 - UTP-10 settings 9 F1 mem F1 analog. M#1-8 F1 wdi F1 w F1 wi F2 cod F2 digit. M#1-16 F2 - wii F3 lcd F3 ROLMATT F4 - kbd F2 d F4 - ACTIA F3 i F4 - Lm F1 Øl=Lend-Lstrt F2 Øl=2*pi*r F3 - Øl=manual F2 - Tp F1 T1 F2 T2 F3 T3 F4 T4 F3 SvN F4 sys F1 UTC F2 con/backl F3 ver F4 ES F1 Auto. off F2 - Buzzer Battery bargraph UTP-10 quick start v1.01 8
Digital Application Sheet
VEHICLE MANUFACTURER MODEL YEAR OF MANUFACTURE ENGINE TYPE TRANSMISSION MITSUBISHI Shogun / Pajero / Montero 2007 on 3.2 DI-DC 5 Speed Manual VOLTAGE 2v STONERIDGE DIGITAL KIT FOR THIS VEHICLE: 7800-078
More informationDigital Application Sheet
VEHICLE MANUFACTURER MODEL YEAR OF MANUFACTURE ENGINE TYPE TRANSMISSION RENAULT Maxity 2008 on 2.5L / 3.0L 5-6 SPEED VOLTAGE 2v STONERIDGE DIGITAL KIT FOR THIS VEHICLE: 7800-3 PARTS LIST SE5000 TACHOGRAPH
More informationBRAKE TESTER DECELEROMETER
OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch
More informationTachoDrive key + TachoDrive Express software
TachoDrive key + TachoDrive Express software Instruction manual November 2007 v 1.01 MATT 2007 All rights reserved Table of contents 0. Introduction...4 1. TachoDrive device...5 1.1 General description...5
More informationCompact Test Computer II
Compact Test Computer II www.dtco.vdo.com CTC II Operating Instructions Imprint The information contained in this documentation is subject to change without prior notice. In doing so, Continental Trading
More informationDigital Application Sheet
VEHICLE MANUFACTURER MODEL YEAR OF MANUFACTURE ENGINE TYPE TRANSMISSION VOLTAGE LDV SI/006 MAXUS 2006 Euro 4 2.5 CRD Manual, 5 Speed. 2v STONERIDGE DIGITAL KIT FOR THIS VEHICLE: 7800-059 PARTS LIST QUANTITY
More informationAfter opening the printer drawer, the data plate is visible showing 'e1 84'. Any printer paper used must also show on the reverse side "e1 84".
DRIVERS SHORT OPERATING INSTRUCTIONS DTCO 1381 Display and Operating Elements Display Menu button Tear-off edge Driver 1 keypad Card slot 1 Download interface Driver 2 keypad Card slot 2 Unlock button
More informationOrica Seismic Electronic Initiation System OSEIS TESTER. Manual
Orica Seismic Electronic Initiation System OSEIS TESTER Manual Version 2.00a, November 2006 Overview Oseis System... 2 1. Oseis Detonator, Tester and accessories... 3 1.1 Oseis electronic detonator...
More informationKEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER
INSTRUCTION MANUAL STEERING WHEEL TORQUE/ INCLINOMETER SYSTEM MODEL KEI-234 W / INTERNAL BARCODE SCANNER REVISION DATE: 17-AUG-1999 1 GENERAL DESCRIPTION... 3 INSTALLATION... 3 SYSTEM SETUP... 4 To change
More informationSTC-8250A Digital Tachograph Operation Manual
STC-8250A Digital Tachograph Operation Manual AVU-AGD-OPE Rev 0.7 19.10.2017 Declaration of Confirmation This declaration, officially register the confirmation of the product named as Definition : Aselsan
More informationMICROPROCESSOR BASED CONTROLLER
MICROPROCESSOR BASED CONTROLLER Electronic Controller for Bus HVAC Front Box Units FrontAIRE II SERVICE MANUAL TK 53337-3-MM (Rev. 0, 09/06) 2006 THERMO KING Table of contents 1. General Information...
More informationAUTOLOG 1000 OPERATIONAL MENU SYSTEM SUMMARY
AUTOLOG 1000 OPERATIONAL MENU SYSTEM SUMMARY Fifth edition Jan 1998 Autolog 1000 Operational Menu Summary Page 1 The operational menu groups The Autolog display and function selector consists of 9 menu
More informationGloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II
GloboFleet GloboFleet Downloadkey II User Manual EAN / GTIN 4260179020391 Inhalt Content / Overview...2 Read out tachograph data...3 Read out tachograph data and driver card...4 Transfer data to a computer...5
More informationTechnical Service Information Bulletin
Technical Service Information Bulletin August 4, 2003 Title: Models: 02 03 ES 300 & 04 05 ES 330 REVISION NOTICE: April 1, 2005: 2004 2005 model year ES 330 vehicles have been added to Applicable Vehicles.
More informationIS0306 rev. B ecn /2013. MG Tachometer (NMEA2000 and J-1939) TACH 1760 RPM FUEL. Installation / User Manual.
IS0306 rev. B ecn 9055 11/2013 MG3000 - Tachometer (NMEA2000 and J-1939) TACH 1760 RPM FUEL Installation / User Manual www.faria-instruments.com IMPORTANT: This User s Guide outlines the functionality
More informationTECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2
FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2 Rel. 4.0 3.0 2.0 1.0 0.0 Release Disposal Aim Modifications on chapter 8 and 13 Deleted automatic and manual test procedure General modifications Added par.
More informationGloboFleet. User manual. GloboFleet Downloadkey EAN / GTIN
GloboFleet GloboFleet Downloadkey User manual EAN / GTIN 4260179020070 Content Content / Overview...2 Read out tachograph data...3 Read out tachograph data and driver card...4 Transfer data to a computer...5
More informationSITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03
s Operating Manual Edition 09/2006 - Revision 03 SITRANS FUE950 Energy calculator type SITRANS FUE950 District heating application Chilled water application Combined cooling/heating application [ ] Order
More informationST Wiring diagram. Product description. Temperature controller. Order number
ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point
More informationThe BOWMONK AFM2 is the modern day equivalent of a mechanical decelerometer such as the Bowmonk Brakemeter or Tapley Brake Meter.
AFM2 Portable FAA (& others) Approved Easy to Use Compatible with ABS Braking Systems* Built-in Printer PC Link Capability Backlit Display for Night Use Built-in Rechargeable Battery Accessories available,
More informationAutomatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list
OPERATOR'S MANUAL Automatic Genset Controller, AGC-4 Display readings Push-button functions handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com
More informationUSER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72
BT D-01 1 2 USER GUIDE GB Digital Thermostat 4-25 GUIDE D UTILISATION F Thermostat digital 26-49 Bedienungsanleitung D Termostato digital 50-72 GUÍA DE USUARIO ES Termostato digital 74-97 GUIA DO UTILIZADOR
More informationQUICK START GUIDE. (407) /
QUICK START GUIDE (407) 774-2447 / www.sctflash.com SECTION 1: PARTS + CHECKLIST X4 DEVICE MICRO USB CABLE HDMI/OBD II CABLE TOOLS NEEDED: Fuse Puller Voltage Tester Battery Charger Pliers SECTION 2: PRE-INSTALL
More informationSmartPak Welding Controller WK-MPS-16 Constant Current
SmartPak Welding Controller WK-MPS-16 Constant Current Features Latest state of the art ATMEL 8 bit microprocessor technology Synchronous digital welding control allows absolute precision Up to16 programmers
More informationOperations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical
PowerView PV380-R2 Murphy Standard Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety
More informationSetup for using our speedometer with GPS sensor
Setup for using our speedometer with GPS sensor Wiring: Speedometer red (1) power +12V Speedometer black (5) - ground Speedometer green (4) LED illumination (can be 12V) Speedometer blue (7) signal input,
More informationUser manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.
Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI
More informationPowerView PV380-R2 Mechanical Configuration
PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive
More informationUser Manual Version AUTOSTOP Maxi. I n V e h i c l e B r a k e T e s t e r
User Manual Version 8.22 AUTOSTOP Maxi I n V e h i c l e B r a k e T e s t e r Table of Contents AutoStop Maxi 1. UNPACKING AND FIRST TIME USE... 2 1.1 Activating your meter... 2 1.2 Selecting Region...
More informationELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A
ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output
More informationFORD EXP-1050 Vehicle Battery Diagnostic Platform. For testing 6 and 12 volt automotive batteries, and 24 volt electrical systems INSTRUCTION MANUAL
FORD EXP-1050 Vehicle Battery Diagnostic Platform For testing 6 and 12 volt automotive batteries, and 24 volt electrical systems INSTRUCTION MANUAL This page intentionally left blank. Contents Contents
More informationPikoLoad Product. PikoLoad. Unit for the legal download of the mass memory of the digital tachograph
PikoLoad Product PikoLoad Unit for the legal download of the mass memory of the digital tachograph Page 1 Present Situation Digital Tachograph New trucks (>3,5 to) are factory fitted with digital tachographs
More informationGenerator Sets Controller 210. Operation Manual. Ver1.0
Generator Sets Controller 210 Operation Manual Ver1.0 Note This information could include technical inaccuracies or typographical error. Manufacturer may make improvements and/or changes in the product(s)
More informationNexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family
NexSysLink CAN Instruments Product Family Operation Manual NMEA 2000 SAE J1939 Indmar Engines Contact Beede Beede Electrical Instrument Company, Inc. 88 Village Street Penacook, NH 03303 (603) 753-6362
More informationOperations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical
PowerView PV350-R2 Murphy Standard Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety
More informationThe measurements module provides the following engine features information:
1. INTRODUCTION The CEM6 control board is a monitoring network signal and monitoring and control generator feeding device. The device consists of 2 different modules: - Visualization module. The visualization
More informationRally computer 3 Rally computer 3.GPS *
Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to
More informationUser Manual Version AUTOSTOP Heavy I n V e h i c l e B r a k e T e s t e r
User Manual Version 7.12 AUTOSTOP Heavy I n V e h i c l e B r a k e T e s t e r Table of Contents AutoStop Heavy User Manual Version 7.12 1. UNPACKING AND FIRST TIME USE...2 1.1 Activating your meter...2
More informationELD DRIVER GUIDE June 21, 2018
ELD DRIVER GUIDE June 21, 2018 Contents Getting Started with PrePass ELD...4 Enroll in the PrePass ELD Program... 4 For a Carrier Enroll in the ELD Service... 4 For a Driver Get Driver Login Information...
More informationOPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets
Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599
More informationSwitch select of sender types:
Full sweep minor gauges wiring: B -------------------------------------------------- battery or +12V input. L -------------------------------------------------- LED illumination, for back lighting, dimmable.
More informationUser s Manual XOB15091 OBD II / EOBD CODE READER. All Rights Reserved. Warranty and Service
5. Warranty and Service 5.1 Limited One Year Warranty The manufacturer/supplier warranty provided to customers for this product will be free from all defects in materials and workmanship for a period of
More informationRev. 12/14/2001. PC-5500 PC-5750 Operation Manual
Rev. 12/14/2001 PC-5500 PC-5750 Operation Manual Operation Configuration Troubleshooting PC-5500 PC-5750 Custom Control Systems Inc. 2007 Beech Grove Place Utica, NY 13501 (315) 732-1990 www.customcontrolsystems.com
More informationCompression/Tension Testing Machines
Manual Cement Compression and Flexure Testing Machines UTCM-6310/UTCM-6410 The UTCM-6310 and UTCM-6410 single and double testing chamber Manual compression and flexure testing machines are designed to
More informationImportant instructions
Operation manual Please read this manual, before starting the unit. It contains important notes on commissioning and handling. Keep these instructions for future reference. Be careful even if you pass
More informationService Only. Digital Tachograph DTCO Operating instructions Company & Driver
Digital Tachograph DTCO 3.0 Operating instructions Company & Driver www.fleet.vdo.com Imprint Dear user, The DTCO 1381 digital tachograph, with its system components, is an EC recording device that complies
More informationUSER GUIDE 1 USER GUIDE
USER GUIDE 1 USER GUIDE 1 TABLE OF CONTENTS IN THE BOX...3 NAVIGATING THE MENUS...3 MENU LAYOUT...3 UPDATE YOUR PROGRAMMER...4 CONNECT WITH THE MOTORCYCLE...5 TUNE YOUR MOTORCYCLE...6 ADDITIONAL FEATURES...8
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationOBDCheck VP39 OBDII/EOBD SCAN TOOL. User Manual. The Best Solution to Read & Erase Trouble Codes for OBD II Compliant Vehicles.
OBDCheck VP39 OBDII/EOBD SCAN TOOL User Manual The Best Solution to Read & Erase Trouble Codes for OBD II Compliant Vehicles. Table of Contents 1. Safety Precautions and Warnings...1 2. General Information
More informationMODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER
MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER Wiring Diagram The MVX-2011 gauges will work on 2011-up Softail models with 5 gauges or 2012-up Dyna models with 5 gauges. It is a direct plug in on these
More informationInstallation and User Guide CCMS312
SEITE 1 Installation and User Guide CCMS312 Description The charging current management system CCMS312 is used as a control unit for up to 8 emh1 (EVCC). Functions of the CCMS312: Simple load management
More informationRegional Sales Manager
Colin Morris Regional Sales Manager ntinental Automotive Trading UK Lt Recording, Transfer and Handling of Data with the New VDO Digital Tachograph Why Convert to a Digital Tachograph? The VDO DTCO version
More informationGuide to Driver Decision Support Compatibility
Guide to Driver Decision Support Compatibility Document Change Record Revision Date Owner Details 0.1 11 th Feb 2015 James Scott-Evans Initial Draft 0.2 25 th Apr 2016 James Scott-Evans VDO 2.2 released
More informationContents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14
UPDATED February 2, 2018 Contents Getting Started with PrePass ELD...4 Enroll in the PrePass ELD Program... 4 For a Carrier Enroll in the ELD Service... 4 For a Driver Get Driver Login Information... 4
More informationXC Instrumentation System Owner s Manual Revision /05/06
XC Instrumentation System Owner s Manual Revision 3.0 07/05/06 XC INSTRUMENTATION SYSTEM OWNER S MANUAL 1 Revision History Date New Revision Level Revision Description 11/08/05 1.0 Initial release 05/24/06
More informationVDO TPMS Tools. VDO / IAM Public. Continue
VDO TPMS Tools VDO TPMS Pro VDO TPMS Pro VDO TPMS Pro is ideally adapted to the needs of workshop technicians. Thanks to the icon-based navigation on the high-resolution 4.3 color display, scrolling through
More informationModbus Integration Integration for Modbus Functionality for VT8600 Series
Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS
More informationGFX2000. Fuel Management System. User Guide
R GFX2000 Fuel Management System User Guide Contents Introduction Quick Start 1 1 Setup General Tab 2 Key or Card 2 Fueling Time/MPG Flag Tab 3 Address/Message Tab 3 Pump Configuration 4 View Vehicle Data
More informationOperation Manual. For technical help please contact Livorsi Marine at or us at
For technical help please contact Livorsi Marine at 4-5- or email us at info@livorsi.com This Operation Manual system is compatible with any Smartcraft, NMEA, J99 or Indmar engine. Livorsi Marine Inc 5
More informationEC200 ELECTRONIC CONTROL SYSTEM
1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for
More informationFUNCTION SELECTION. Check the Trouble Code SCAN-100. Preceding Work: Perform the Entering Diagnosis Procedures
29 FUNCTION SELECTION Check the Trouble Code Preceding Work: Perform the Entering Diagnosis Procedures 1. Select 1] TROUBLE CODE and press ENTER in FUNCTION SELECTION screen. 2. The DIAGNOSTIC TROUBLE
More informationSNMP dedicated to ORVALDI Solar Infini
SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation
More informationInstallation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................
More informationUniversal Wireless Dashboard Y-Dash + Android App Y-Dash GT. User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.
Universal Wireless Dashboard + Android App GT User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.3 Page 2 is an electronic microprocessor based device that collects analog and digital
More informationTable of Contents. Disclaimers Warranty... 5 Gas Tuner Instructions Diesel Tuner Instructions Fuse Removal...
INSTALLATION Table of Contents Disclaimers... 3-4 Warranty... 5 Gas Tuner Instructions... 6-10 Diesel Tuner Instructions... 11-14 Fuse Removal... 15 2 Release The Beast Thanks for your purchase of a Quadzilla
More informationTop quality Plug & weigh
FORKLIFT TRUCK SCALES iforks Completely wireless fork scale BENEFITS 5 Minutes installation Completely wireless: no cabling Digital calibration Weight correction for forklift mast tilt No de-rating of
More informationTable of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11
Table of Contents 1. INTRODUCTION...1 2. GENERAL INFORMATION-ABOUT OBDII/EOBD...1 2.1 ON-BOARD DIAGNOSTICS (OBD) II...1 2.2 DIAGNOSTIC TROUBLE CODES (DTCS)...2 2.3 LOCATION OF THE DATA LINK CONNECTOR (DLC)...3
More informationSPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS
SPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...MENU SYSTEM PAGE 9...INSTALLATION DIAGRAMS PAGE 13...INSTALLATION
More informationCurveMaker HD v1.0 2Ki Programmable Ignition programming software
Contents CurveMaker HD v1.0 2Ki Programmable Ignition programming software Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Programming
More informationInstallation Instructions ISOBUS Liquid ECU
Installation Instructions ISOBUS Liquid ECU Liquid Fertilizer & Ammonia Display Screen Sprayer Display Screen Last Update: 3/1/2018 SW Version Liquid v.01.00.04.00 - ECU HW: 1.6-1.7 SW Version Liquid v.02.00.01.00
More informationGREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).
MEASURE AND CONTROL GREASE CONTROL GUNS AND ACCESSORIES GREASE METERS OIL CONTROL GUNS AND ACCESSORIES OIL METERS OIL METER ACCESSORIES FLUID CONTROL GUNS FLUID METERS HIGH FLOW IN LINE METERS ADVANCED
More informationSPEEDRIVE INSTRUCTIONS MANUAL
EN SPEEDRIVE INSTRUCTIONS MANUAL Safety warning. The following symbols shown beside a paragraph represent danger warnings associated to the failure to comply with the corresponding instructions. DANGER!
More informationMATRIX LLC LEVEL CONTROL PANEL
MATRIX LLC LEVEL CONTROL PANEL Installation Operation Maintenance Manual 1-26-09 REV-0.3 1 INDEX Introduction. 3 Product Configurations..... 4 I/O Descriptions. 8 Operation o Intercooler, Accumulator,
More informationAttention! 1 Accessories. 2-1 Installation description ❹ ❺. Please proceed as follows
Thank you for purchasing the TNT-B meter for Yamaha Bolt. Before installing, please read the instruction carefully and keep it for future reference. Attention! For installation, please follow the steps
More informationECONOMISER SERIES E2T USER MANUAL
TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014
More informationOwner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer
Owner s Manual MG2000 Speedometer for use with SmartCraft Tachometer IS0211 rev. E ecr#6395 08/2006 4/5/05 Changes 12/21 Index Description Available Functions for display page 1 Default Screens page 1
More informationAutomobile Accessories
Automobile Accessories On-Board Diagnostic2 Scanner AOBD2A OBDII/EOBD+CAN AOBD2A welcome! Thank you for buying Tacklifescan OBDII Diagnostic Scanner! The Tacklifescan OBDII Diagnostic Scanner allows you
More informationInstallation and use. Controller for Rapid Bike Evo and Rapid Bike Racing modules. Issued by: PM approved by DG Rev.00 date 09/01/15 pag.
Installation and use Controller for Rapid Bike Evo and Rapid Bike Racing modules Issued by: PM approved by DG Rev.00 date 09/01/15 pag. 1/10 Description YOUTUNE is a calibration device showing data relative
More informationM u l t i P o w e r. CM MultiPower. Installation and Operating Manual
M u l t i P o w e r CM MultiPower Installation and Operating Manual Index 1. Introduction of the 4HS submersible pumps range... 3 2. Safety Instructions... 4 3. CM MP installation... 5 3.1 Electric wiring...
More informationCurveMaker DFS v2.0 Dyna FS Ignition Programming Software
CurveMaker DFS v2.0 Dyna FS Ignition Programming Software Contents Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Introduction
More informationExpandable Electrical Diagnostic Platform
Battery Management Innovation Expandable Electrical Diagnostic Platform For testing 6- and 12-volt heavy-duty, automotive, and commercial batteries, and 12-volt and 24-volt charging systems. INSTRUCTION
More informationMDX-653P INSTRUCTION MANUAL. Battery Conductance and Electrical System Analyzer
Battery Conductance and Electrical System Analyzer For 6 & 12-volt automotive starting batteries and 12 & 24-volt starting/charging systems INSTRUCTION MANUAL Blank page Contents Introduction & Overview
More informationSensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator
Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator SensoStar C DE-18-MI004-PTB037 (MID heat) DE-18-M-PTB-0049 (national German cooling)
More informationUser Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S ( UK)
User Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S (105447-UK) 13-03-2007 Fig 1a (calibrator view) 6 Reference sensor (if available) 5 CA LI
More information-SQA- SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION. -Module Number Session
-SQA- SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION -Module Number- 2210034 -Session-1994-95 -Superclass- -Title- ZJ MOTOR VEHICLE INSPECTION: TACHOGRAPHS
More informationTop quality For industrial use
HAND PALLET TRUCK SCALES RAVAS-110 Pallet truck scale with basic scale functions BENEFITS: The RAVAS work horse All basic scale functions Competitive pricing Low power consumption For checking incoming
More informationPCT-3001 plus. Display LCD
PCT3 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS DESCRIPTION Pressure controller for refrigeration systems capable to control suction (compressors) and discharge (fans) pressures. It is possible
More informationBegin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A
HIMOTO ZTW Brushless Electronic Speed Control for car or truck Thank you for purchasing ZTW Brushless Electronic Speed Controller(ESC). The ZTW electronic speed control (ESC) is specifically designed for
More informationBitte decken Sie die schraffierte Fläche mit einem Bild ab. Please cover the shaded area with a picture. (24,4 x 11,0 cm)
Bitte decken Sie die schraffierte Fläche mit einem Bild ab. Please cover the shaded area with a picture. (24,4 x 11,0 cm) Digital Tachographs: Efforts of installation and maintenance Special session of
More informationPDC PROPELLER DE-ICE CONTROLLER
PDC PROPELLER DE-ICE CONTROLLER OPERATIONAL & INSTALL MANUAL Updated: 14 October 2016 Copyright 2016 by VR Avionics Inc. All rights reserved. This User and Installation Guide and the information contained
More informationAdvanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list
OPERATOR'S MANUAL Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com
More informationFlue Gas Analyzer IMR 1100F
Flue Gas Analyzer IMR Environmental Equipment. Inc. 3634 Central Ave. St. Petersburg Florida 33711 Tel: 727-328-2818 Fax 727-328-2826 info@imrusa.com www.imrusa.com User Manual INTRODUCTION 3 SAFETY INSTRUCTIONS
More informationGENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:
π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature
More informationCRUISE CONTROL SYSTEM
CRUISE CONTROL CRUISE CONTROL SYSTEM CRUISE CONTROL SYSTEM PRECAUTION 1 1. HANDLING PRECAUTION FOR CRUISE CONTROL SYSTEM (a) Turn the cruise control main switch OFF when not using the cruise control system.
More informationNortoft Electronic A/S, Sejrupvej 38, DK 7323 Give. Program Rain User Manual
Nortoft Electronic A/S, Sejrupvej 38, DK 7323 Give. www.nortoftelectronic.com Program Rain 10-12 Features: Speed regulation Pre- and post-irrigation 4 different speeds Clock Start time is adjustable Stop
More informationDTCO 1381 Rel. 1.3U reliable and efficient The digital tachograph of VDO
www.dtco.vdo.com DTCO 1381 Rel. 1.3U reliable and efficient The digital tachograph of VDO What are my legal obligations as a fleet operator? Since May of 2006, all newly licensed HGVs of more than 3.5
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationParts Certificate. Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account SC
SC0099-18 Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account Issued to Knowtronic ApS Stationsvej 83, DK-4684 HOLMEGARD, Denmark In respect of (part of instrument) OPT Outdoor Payment
More informationCENTOR TORQUE GAUGE - EASY VERSION INSTRUCTION MANUAL. Version 1.3
CENTOR TORQUE GAUGE - EASY VERSION INSTRUCTION MANUAL Version 1.3 Instructions Manual - 1.3 CENTOR Torque Gauge EASY version CONTENTS 1. Introduction to the CENTOR Page 1 2. Starting your measurement Page
More informationVolkswagen Information System. Introduction
Volkswagen Information System Introduction In this section you ll find information about: Using the instrument cluster menus: Basic version Using the instrument cluster menus: Premium version with multi-function
More information