1 CENTOR TORQUE GAUGE - EASY VERSION INSTRUCTION MANUAL Version 1.3
2 Instructions Manual CENTOR Torque Gauge EASY version CONTENTS 1. Introduction to the CENTOR Page 1 2. Starting your measurement Page 2 a) First contact b) Starting with the torque gauge c) Display mode d) Reset function e) Measure units f) Peak value g) Back-light 3. Advanced functions Page 9 a) Limit b) Calculations - Comput c) Screen - Display d) Input / Output e) RS-232 interface f) Test setting g) System setting 4. Associated products Page 15 a) The CENTOR family b) Modules for external sensors c) Manual or motorised test stands d) Grips accessories e) Software f) Link cables Appendices Functions chart Page 18 Keyboard chart Page 20 Error messages Page 21 Flow chart Page 22 Factory settings Page 23 Connections Page 23 Size Page 24
3 1 INTRODUCTION TO THE CENTOR We thank you for choosing the CENTOR torque gauge Easy version manufactured by Andilog Technologies. This new torque gauge is the result of 15 years experience in torque and torque measurement with new electronic technologies offering a higher-performance and more reliable instrument. Though it is a very comprehensive instrument, the CENTOR torque gauge is easy to use. This instruction manual will help you to understand it and get your first results. You will learn to use the advanced functions making the CENTOR torque gauge the core of your measurement system
4 2. STARTING YOUR MEASUREMENTS CAUTION: Check the CENTOR torque gauge and all parts supplied in its carrying case. Confirm that it has not been damaged during transportation. If in doubt, contact ANDILOG TECHNOLOGIES to obtain basic checks to ensure that the gauge has not been damaged. A: First contact The CENTOR torque gauge is supplied with: - Carrying case - Power adaptor - Certificate of calibration - 2 -
5 WARNING! 1. The battery reaches its maximum capacity after several charges. This is very important! The torque gauge will shut down automatically if the battery is too low. A new torque gauge has a battery that does not have its full capacity at the first power on. 2. The battery life is 8 hours of normal use. The gauge should be charged after normal use. If it is not used for a long time, you should charge it every 3 weeks. This to assure maximum life for the batteries. 3. Never connect accessories (hook, plate,...) directly to the sensor rod. Use the extension rod delivered with your instrument. 4. In spite of its mechanical protection, sensor overload can damage the instrument. The instrument stops if the capacity has been exceeded 5 times. You have to return it to ANDILOG TECHNOLOGIES for checking. 5. The gauge can be affixed to a test frame via two M5 screws, which should not extend through the back cover more than 3 mm
6 FRONT PANEL SCHEME GRAPHIC DISPLAY OUTPUT CONNECTOR (RS232/ANALOG/DIGIMATIC) BACK LIGHT CONNECTOR FOR EXTERNAL SENSOR SPIP CANCELS ACTIONS SETTING MODE RESET BUTTON TARE DISPLAY OF PEAK VALUES OR CALCULATIONS DATA TRANSFER ON/OFF BUTTON UNIT CHANGE - 4 -
7 B: Starting with the torque gauge Press the I/O button, the information screen showing the status of the CENTOR torque gauge is displayed for 5 seconds and then the main screen is displayed. Software version Active channel and sensor detected ANDILOG CENTOR EA V 1.53 CHAN INT: AF_10_M DATE: 01/01/2000 BAT :100% Gauge version (EA, ST, DL) Battery information CENTOR version: there are 3 versions of CENTOR: CENTOR EASY Referenced as CENTOR EA CENTOR STAR Referenced as CENTOR ST CENTOR DUAL Referenced as CENTOR DL See chapter 5 for the differences between the versions of CENTOR. Software version: the line indicates the software version installed on the torque gauge. Active channel and sensor detected: The CENTOR torque gauge can detect on puwer up, whether internal or external sensors are connected. External sensors are linked to CENTOR Torque Gauge through a special connector called SPIP. (See chap. 5 for further information). If an internal sensor is detected, the internal channel is the measuring channel. If an external sensor is detected, the external channel is the measuring channel. If both an internal and external sensors are detected, the external sensor has priority and then the external channel is the measuring channel. After detecting the measuring channel, the torque gauge displays the type of sensor linked to this channel. Current date: displayed according to the format: DD / MM / YYYY
8 Battery information: When the battery is low, a low battery message is displayed on the screen as the gauge is turned on, before carrying out tests. If the charger is connected, the message «CHARG» will be displayed. While displaying low battery indication, CENTOR torque gauge runs internal tests. If during these tests, problems are detected, the internal information screen is displayed. An error message indicates that the torque gauge is not in optimum operating condition for measuring. Please see the Appendice chapter for the meaning of indications and error messages. If the error detected makes measurement impossible (defective sensor for example), the display will hold and it will be impossible to take any further action. Please return the instrument to ANDILOG TECHNOLOGIES for examination. If the error detected does not make measurement impossible (low battery for example) you can switch to the main screen by pressing MAX button. C: Display mode NOTE: Described here are manufacturer settings, prepared by ANDILOG TECHNOLOGIES for delivery. Sensor Capacity 50 Nm Measure Unit Line 1 Line VLI VLI Bar graph Status line When turned on, CENTOR torque gauge displays a small square in the middle of main screen (line 1). This small square slides from left to right and then the value of the torque applied to the torque gauge sensor appears on line 1 in large letters. If no torque is applied, CENTOR torque gauge displays «0». Sensor Capacity: the range of the sensor detected can be displayed at any time, even for additional external sensor
9 Measure unit: indicates the unit used for the display. Several units are available. Press the UNIT button to change the measure unit. Line 1: displays the current reading. Bar graph: a black line is the representation of the applied torque. If the bar graph is full, it means that the sensors maximum range is reached: risk of overload! Line 2: displays the maximum, minimum, current values and calculations. Can be selected by pressing MAX button. Status line: Low battery indication: pictogram indicating the battery power status via 4 horizontal lines which respectively symbolize 25%, 50%, 75% and 100% of power. When adaptor is connected, this pictogram flashes. An easy-to-remember small symbol indicates the direction of the torque exerted on the sensor ( ). VAL 1: indicates the value displayed on line 1. You can effectively modify the information displayed on this line. We will see in Chapter 4 part C how to change the displayed value. NOTE: on lines 1 and 2 you can display the following values: VLI: current value MXI: maximum value MNI: minimum value D: Reset function Press on ZERO button to reset the torque gauge. This button allows for tare. The gauge will take into consideration the weight of accessories (hook or plate) fixed on the sensor s rod. Pressing this button resets all memories and peak values. NOTE: When turned ON the CENTOR completes several self-tests to check the sensor s health. It is possible to leave tools fixed on the torque gauge, but the total weight must not exceed 20% of the sensor s maximum capacity. E: Measure unit To change the unit of measure, press UNIT button. When the torque gauge has an external sensor attached, it detects the type of sensor connected and displays the corresponding units
10 F: Peak values The CENTOR automatically calculates peak values (maximum and minimum) and systematically displays them on line 2. Pressing MAX button makes max. value, min. value and current value successively display (as well as a calculation if it has been set). To reset those values press the ZERO button. G: Backlight You can turn on the backlight by pressing O button. When using the torque gauge on battery, the backlight automatically turns off after 3 minutes of operation. The total battery life the CENTOR will be reduced when the backlight is turned on. When the gauge is used with the charger, the backlight does not switch off
11 3. ADVANCED FUNCTIONS The CENTOR torque gauge has several features and settings making it well adapted to perform any kind of test. To optimize the torque gauge operation to your application, we will study all the setting possibilities here. Parameters can be set via the setting menu by pressing the M button. The setting screen appears and the keyboard functions change: A On/Off Turn the gauge on or off B ZERO Arrow to the left: displaces the cursor to the left C Units Arrow downward: displaces the cursor to the bottom D TDX Arrow to the right: displaces the cursor to the right and validates E MAX Arrow upward: displaces the cursor to top F M Switches to the previous screen saving modifications. G O Turn on the backlit. E X Switches to the previous screen cancelling modifications. Setting screen: MENU CENTOR LIMITS DISPLAY IN/OUT RS232 STATS SYSTEM END TDX To move within the menu, use - MAX and - UNIT buttons To select the desired function, highlight it and press the TDX button. In this screen, ZERO button is inactive. To switch to display mode, use M button. In the following screens, the operating mode is the same. In any other screen whatever the position of the cursor: X : switches to the previous screen cancelling the modifications. M : switches to the previous screen saving the modifications
12 Following are the torque gauge functions described one by one: A: LIMITS Limits allow the definition of actions taken by the torque gauge when the limit set value is reached. LIMITS Chan.I YES UNIT Nm T T DEFAULT INT BEEP YES TYPE VAL MENU TDX From Menu, highlight Limits and select with. On threshold screen, Chan. I or Chan. E is displayed according to the detected sensor. You can display YES or NO (via and buttons) to activate or deactivate the limits function. When the function is activated, parameters of the limit function are displayed: UNIT (depending on sensor) defines the unit chosen for the threshold. T1 (sign + 4 digits) determines the value of upper limit (from 0 to 9999). T2 (sign + 4 digits) determines the value of lower limit (from 0 to 9999). DEFAULT (INT or EXT) BEEP (YES/NO) TYPE (MIN/ MAX/ COM/ VAL) defines if the action zone is inside or outside limits. activates audio alarm if the value exceeds limits. defines on which value the limit is applied: minimum, maximum, calculation or current reading. Save settings by pressing M button. In the main screen, the status line is modified: signs <<, =, >> are displayed. They display if the value is respectively below the limit, inside the limit or above the limits. This function allows you, for example, to stop a motorised stand (For a precise stop, use slow speeds) or turn on a light, sound a beep more details are available in Chapter 4 part C Input/Output If only one limit is necessary (max value for example) enter the max or min capacity of the sensor for the second limit value
13 C: DISPLAY From menu, select DISPLAY and validate with. DISPLAY LINE1 VLI LINE2 MXI SIGN COM DECIMA 4 BARGR YES REFR N DIRECT H AUTOFF 15 MENU TDX Exit this screen by pressing M button to save your parameters. From this menu you can set all main screen display parameters. Line 1 VLI, MXI, MNI Line 2 NO,... Sign NO,COM,TRA Decima 1,2,3,4 Bargr YES, NO determines the displayed value on line 1: current value (VL), maximum (MX), minimum (MN) value determines if line 2 is displayed and what is displayed on this line as on line 1. NOTE: If line 2 is not displayed, pressing MAX button Will show it for 5 sec., to briefly display a maximum value for example. determines the displayed sign, if so it indicates the direction of the torque (for positive sign), COM for compression and TRA for traction. number of decimals places displayed, 4 maximum. display the bar graph or not REFR S,N,F setting the screen updating speed (S=1Hz, N=2 Hz, F=3 Hz) DIRECT. H, B Autoff NO,5, 10, 15 determines the direction of display, normal or reverse: the front panel buttons are not affected by this parameter. determines if torque gauge stops when no button is activated for 5, 10, 15 minutes. CAUTION: if Autoff displays NO, please use the torque gauge with the charger to avoid interrupting the measuring process because of low battery condition
14 D: Input / Output From the menu, select IN/OUT and valid with. INPUTS PEDAL TAR TOP O OUTPUTS TOP1 0 TOP2 0 ANAL NO DIGI NO RS232 NO MENU TDX Pedal TAR, O/I, O/E, MAX, TDX, END, STA Determines action of the pedal. The pedal is connected to plugs A and B of the output. TAR: tare torque; simulate the ZERO button. O/I: tare the internal sensor only O/E: tare the external sensor only MAX: simulate the MAX button TDX: simulate the TDX button END: simulate the X button (used to stop the test) TOP O, F TOP1 O, F, I+, I- TOP2 ANAL YES, NO Defines if the gauge should do the TOP action (changing state of analog input when the contact opens ( O ) or closes ( F )) Characterizes the signals used for external output (see limits and calculation). O: simulate an opened contact F: simulate a closed contact I+: simulate a positive pulse I-: simulate a negative pulse See TOP1 Defines if the analog output is active or not. DIGI NO, VLI, CLI, MXI, MNI Defines if digimatic output is activated and what is the value transmitted: current value (VLI), maximum torque (MXI), minimum torque (MNI) or calculation (CPI). RS232 NO,IMP, CON Defines if RS232 output is activated and if it runs in continuous (CON) or impulse mode (IMP) using the TDX button when required. CAUTION: with CENTOR you can only use one output at a time
15 E: RS232 interface From the menu, select RS232 and valid with. RS232 E/S Bds 9600 Par NO Bits 8 Stop 1 Demand F CR YES LF YES Sign YES Unit NO DatHour YES MENU TDX The first part of the screen shows parameters of RS232 transmission and can be modified via and buttons. The second part corresponds to character sequence sent: Demand: F torque gauge sends current value P maximum value V minimum value T last 100 calculated values CR, LF, Sign, Unit, DatHour can be set to YES if user wants each transmitted value to contain a carriage return (CR), a line feed (LF), a sign, a unit, the date and time (DatHour). Exit the screen by pressing M button to save the parameters
16 G: STATS This menu allows you to setup the statistical feature of the CENTOR series. This feature is designed to store up to 100 measurements and to calculate the mean, standard deviation and the st.dev/mean value (coefficient of variation). STATS Mes/Samp 2 Oper. 05 Unit Nm Mes/Samp Oper Unit STATS MXI : defines the quantity of measurements performed on each sample. : defines the quantity of samples to be tested. : measuring unit. : Indicates which values are stored and the statistics Samp1 : Indicates the sample # Mea StDev S/M : mean value : standard deviation : standard deviation divides by the mean value or coefficient of variation H: System setting This screen displays the general information of your CENTOR. SYSTEM CENTOR F:3.17/H30 01/01/ :24 >ENGLISH< SPIP AV10 N /11/1999 MENU TDX Exit the screen by pressing M button to save the settings
17 4. Associated products A: CENTOR family There are several types of CENTOR torque gauges with increasing capabilities according to the chosen version. CENTOR Easy: first model of CENTOR family with simple calculation and communication functions. CENTOR Star: first graphic type with numerous additional calculation functions and capability to read and recognize numerous external sensors. CENTOR Dual: is the most sophisticated torque gauge model with CENTOR easy and CENTOR star functions. Plus the capability of simultaneously reading two sensors (torque + torque; torque + torque, torque + displacement; torque + angle; ect.). NOTE: Whatever the CENTOR torque gauge model, it is may possible to modify the torque gauge type. If you wish to update your CENTOR torque gauge, please contact your ANDILOG TECHNOLOGIES dealer. If you want more information about the CENTOR family, please contact your ANDILOG TECHNOLOGIES dealer or visit our web site: B. Modules for external sensors One of CENTOR torque gauges has the capability of reading any type of torque sensor. Thus an external sensor with a different capacity can be used with CENTOR torque gauge without buying a new torque gauge. ANDILOG TECHNOLOGIES uses a special cable for this. This cable links the external sensor and the torque gauge. It is equipped with a connector or module called SPIP. SPIP module is a tiny case containing the definition and calibration settings of sensor. When SPIP is connected to the torque gauge, the internal sensor (if there is one) is disconnected and the torque gauge takes into consideration the information from the new sensor and displays data from this sensor. Disconnecting the SPIP makes the internal sensor active again. In some applications (i.e. torque sensors), where is no internal sensor available, CENTOR torque gauge only uses external sensors equipped with SPIPs. Another exceptional feature of this type of electronic instrument (sampling rate of 1000 Hz, autonomous, integrated calculation and thresholds) is the ability, thanks to SPIP module, to read not only torque and torque sensors, but also to read values from linear displacement sensor (analog or incremental sensors), rotational displacement sensor (analog or incremental sensors), pressure sensor, etc. Thanks to the SPIP module, CENTOR can read the type of sensor connected and chooses appropriate unit choices. If you want to connect your CENTOR to another sensor, contact your ANDILOG TECHNOLOGIES dealer
18 C: Manual or motorised test stands To ensure a precise measurement, it is important that CENTOR torque gauge is placed in the axis of the torque throughout the test. To ensure this placement is correct, ANDILOG and ANDILOG TECHNOLOGIES have developed a complete range of simple and sophisticated test stands. These are manual or motorised test stands, some of them being computer-controlled. If you want more information about test stands, contact your ANDILOG TECHNOLOGIES dealer or visit our web site D: Gripping accessories ANDILOG TECHNOLOGIES offers a series of gripping accessories adapted to different tests: hooks, plates, pliers, self-squeezing jaws, eccentric jaws, peeling fixture, etc If you want to receive our catalog, contact your ANDILOG TECHNOLOGIES dealer. E: Acquisition software ANDILOG TECHNOLOGIES has developed several programs to save and analyse values. You want to analyse values on a chart: RSIC software has been developed to this. You want to capture the values graph and use graphics tools: CALIGRAF software goes further in tests analysis. If you wish to connect your CENTOR torque gauge to a PC via one of our programs, contact your ANDILOG TECHNOLOGIES dealer. F: Interface Cables Several interface cables can be used with CENTOR torque gauge: External pedal: allows simulation of a keyboard button Cable for external contact: allows torque calculation from closing /opening of contact (equipped with male-female plugs): Linking cable for motorised test stand STENTOR, allows to stop the stand according to a condition defined by CENTOR torque gauge: Cable for analog link (with male-female plugs): links your gauge to another system Cable for Digimatic link: connect your gauge to a statistical printer Cable for RS232 link: connect your gauge to a computer using the RS232 output Multifunction cable test stand STENTOR control and RS232 link
19 APPENDICES
20 Function chart The different CENTOR versions offer different functions, here is the function chart according to the different torque gauge version. FUNCTIONS AVAILABLE EASY STAR DUAL Resolution 1/1000 X X X Accuracy 0.1% X X X Data Capture Rate 1000 Hz X X X Bar graph display X X X Display of Torque/Time Torque/Time curve X X Display settings X X X Display inversion X X X Possibility to use external sensor (fixed connection) X X X Possibility to read different sensors X X Reading of incremental sensors X X Simultaneous reading of two sensors X Display of 2 sensors graph F (X) X Overload alarm X X X Simultaneous display of current and peak values X X X Selection of the unit of measure X X X Can be used with a pedal X X X Limits settings X X X Limits action on an external contact X X X Motorised test stand control on limit X X X RS232 output settings X X X Bi-directional RS232 output X X X Analogue output X X X Digimatic output X X X Calculations X X Breaking point value X X First peak values X X Torque / Torque value at T time X X Average peak value X X Derived Torque / Torque value X X Torque / Torque value at the opening of contact X X Motorised test stand control after calculation X X Graph Memory X X Last 100 calculated values memory X X X Compatible with RSIC X X X Auto power off X X X Battery life 8 hours in normal use X X X Non volatile settings memory X X X Factory settings memory X X X Customer settings memory X X Restore for setting X X Low battery indication X X X Recall of last calibration date X X X Backlit screen X X X Metal case X X X Rubberised shock-proof protection X X X
21 Splash-proof X X X Industrial oils resistance X X X Drop-proof to 1 m (without accessories) X X X Fixing through threaded holes / metric thread X X X Supplied in carrying case with accessories and power adaptor X X X Supplied with calibration certificate X X X English or French instruction manual (customer preference) X X X Manufactured in France X X X 2 year warranty (except for sensor overload) X X X
22 Keyboard chart BUTTON N PRESS BUTTON HOLD BUTTON SETTING MODE 1 on/ off Turn the gauge on / off 2 O Backlight on/ off 3 ZERO Resets values Resets charts Left Arrow Erases graph and Switches to TOP1 4 UNIT Changes units Down Arrow 5 MAX Displays max and min Up Arrow values 6 TDX Sends a value Right Arrow through RS232 7 X Stop curve tracing (STAR version) Returns to preceding screen without saving 8 M Setting mode Returns to preceding screen with saving ACTIONS: While Setting screen is displayed: M + X activates factory setting While the system screen is displayed: M + MAX Displays diagnostic screen While the diagnostic screen is displayed: M + MAX to return to preceding screen
23 Error messages Diagnostic screen: This screen is displayed in two cases: After the completion of internal tests, if a minor or major defect has been found. In System Menu, when M + MAX are pressed. Minor defects: Low battery Expired calibration date Press MAX button to continue Major defects: Damaged sensor High number of overloads (>5) Internal error
24 Flow chart Function Values LIMITS Chan. I NO YES Unit depends on the sensor T1 -N to +N T2 -N to +N DEFALUT INT EXT BEEP YES NO TYPE VAL MIN MAX COM DISPLAY LINE1 VLI MXI MNI LINE2 NO VLI MNI SIGN NO COM TRA DECIMA BARG R YES NO REFR R N L DIRECT H B AUTOFF NO CURVE NO YES SCALE AXIS + - +/- IN/OUT PEDAL TAR O/I O/E MAX TDX END TOP O F TOP1 O F I+ I- TOP2 O F I+ I- ANAL DIGI NO VLI MXI MNI RS232 NO IMP CON RS232 Bds Par NO PAIR IMPR Bits 8 Stop 1 2 Deamnd F P V C T W CR NO YES LF NO YES Sign NO YES Unit NO YES DatHour NO YES STATS Mes/Samp 0 9 Oper Unit depends on the sensor
25 Factory Settings Function LIMITS Chan. I Values NO DISPLAY LINE1 VLI LINE2 MXI SIGN TRA DECIMA 4 BARG R YES REFR N DIRECT. H AUTOFF 10 CURVE YES SCALE 50 AXIS +/- IN/OUT PEDAL TOP TOP1 TOP2 ANAL DIGI RS232 TAR O O O NO IMP RS232 Connections Connector detail SubD 15 pins connected to CENTOR electronic card PIN 3 RS232 TXD 4 RS232 5 Digimatic 6 Digimatic 7 Digimatic 8 Digimatic 9 Output Torque N 1 10 Output Torque N 2 11 Input Torque N 1 12 Input Torque pedal 13 GND 14 Analogue output
26 Size
CENTOR TORQUE GAUGE - STAR VERSION INSTRUCTION MANUAL. Version 1.3
CENTOR TORQUE GAUGE - STAR VERSION INSTRUCTION MANUAL Version 1.3 Instructions Manual - 1.3 CENTOR Torque Gauge STAR version CONTENTS 1. Introduction to the CENTOR Page 1 2. Starting your measurement Page
More informationBRAKE TESTER DECELEROMETER
OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch
More informationTECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2
FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2 Rel. 4.0 3.0 2.0 1.0 0.0 Release Disposal Aim Modifications on chapter 8 and 13 Deleted automatic and manual test procedure General modifications Added par.
More informationOVERVIEW OF CONTROLS
π H-5819, H-5820 H-5821, H-5822 DELUXE COUNTING SCALE 1-800-295-5510 uline.com OVERVIEW OF CONTROLS DISPLAY DEFINITIONS # NAME DESCRIPTION 1 DISPLAY 2 1 3 STABLE 4 RECHARGE PAGE 1 OF 8 Displays the total
More informationLafayette Manual Muscle Test System
MAN087 Model 01165 Model 01165 Lafayette Manual Muscle Test System Fax: (765) 423-4111. www.lafayetteinstrument.com. info@lafayetteinstrument.com Lafayette Manual Muscle Test System Table of Contents Features
More informationSAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS
CONTENTS SAC SERIES TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE 1. INSTALLATION 2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS OPERATION
More informationAdvanced Force / Torque Indicator
32-1128 Advanced Force / Torque Indicator The 5i advanced digital force / torque indicator is designed to work with a wide range of Mark-10 remote force and torque sensors (see page 3). With exclusive
More informationPreparing and programming of ESGI 2 LPG supply system manual
Preparing and programming of ESGI 2 LPG supply system manual Part II Instruction of preparing and programming the ESGI system 1 Technical data of the central unit Vs Power supply voltage 0...16V V i_an
More informationtesting to perfection Orbis closure torque tester Operating Manual
testing to perfection Orbis closure torque tester Operating Manual Contents The Orbis Assembly of the Orbis 3 Powering the Orbis 4 Using the Orbis 5 Optional Settings 10 RS232 Commands 13 Dimensions 16
More informationGRAVITY MEASUREMENT, INC.
COUNTING SCALE User and Service Manual Model: CCT10/CCT20 Please read this manual carefully before operation ----General Precautions ----Operating condition and other attentions ----Warranty GRAVITY MEASUREMENT,
More informationMoistureMatch A next generation grain tester
MoistureMatch A next generation grain tester A next generation moisture tester incorporating new and unique technology. Finally, a portable tester that will more accurately match and track with the commercial
More informationNGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS
NGW & HGW SERIES HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE CONTENTS CAUTIONS 1. INSTALLATION 2. SPECIFICATIONS OPERATION MANUAL 3. KEYBOARD LAYOUT AND DESCRIPTION 4. INITIAL SETUP PLEASE READ THIS MANUAL
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationInstruction of connection and programming of the VECTOR controller
Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring
More informationOPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02
OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 1. INTRODUCTION 2. SAFETY INSTRUCTIONS 3. SPECIFICATION 4. OPERATING INSTRUCTIONS AND CONTROL FUNCTIONS 5. SET UP PROCEDURE 6. CONNECTIONS
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationCLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16
User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...
More informationROW PRO DOWN PRESSURE
Operator s Manual ROW PRO DOWN PRESSURE VERSION 2 & 3 Safety Notices... 1 Disclaimer... 1 Row-Pro Down Pressure... 3 Requirements... 3 Setup... 4 Control Mode... 4 Disable Down Pressure Modules... 7 Setting
More informationSmartON / SmartON+ Installation and Use Manual
SmartON / SmartON+ Installation and Use Manual Rev. Date Ver. Ver. Notes document document SmartON SmartViewII 1.0 06/04/2007 3.08 2.30 Pre-release 1.01 10/04/2007 3.08 2.30 Release 1.02 04/10/2007 3.09
More informationT100 Vector Impedance Analyzer. timestechnology.com.hk. User Manual Ver. 1.1
T100 Vector Impedance Analyzer timestechnology.com.hk User Manual Ver. 1.1 T100 is a state of the art portable Vector Impedance Analyzer. This powerful yet handy instrument is specifically designed for
More informationIssue 2.0 December EPAS Midi User Manual EPAS35
Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started
More informationSPG-DIGI. Operating Instruction. Please read carefully before use!
WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com
More informationIntelligent torque meter tester
Intelligent torque meter tester Before using this product, please read the instructions carefully, which will help improve the efficiency of your use of this product Contents 一 About HP Series Torque Meter...2
More informationGENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:
π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature
More informationFuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2
Fuel Level FL1 Revision#2.0, 28/11/2014 For firmware version 1.2 FL1 - User s manual Page intentionally left blank SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION OPERATING INSTRUCTIONS INSTRUMENT
More informationOperating Instructions for the WABCO Diagnostic Controller with Program Card ABS-Hydraulic
WABCO Operating Instructions for the WABCO Diagnostic Controller with Program Card ABS-Hydraulic 446 300 782 0 Operating Instructions for the WABCO Diagnostic Controller with Program Card ABS-Hydr. 446
More informationUser manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.
Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI
More informationFL-100-R (109) Operations and Installation Manual
Page 1 of 23 All specification subject to change 2002-2005 FL-100-R (109) Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual
More informationST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number
ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and
More informationSMARTDRIVE HHT HAND HELD TERMINAL
SMARTDRIVE HHT HAND HELD TERMINAL T E C H N I C A L C A T A L O G Hand Held Terminal POCLAIN HYDRAULICS This document is provided to machine manufacturers integrating POCLAIN-HYDRAULICS hydrostatic transmission
More informationST Wiring diagram. Product description. Temperature controller. Order number
ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point
More informationDusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH
EN Dusty / Dusty Ex Operating Instructions Low-Cost Broken Bag Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Introduction.............................................................. 3 1.1
More informationParker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax
Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, 33659 Bielefeld Phone ++49-521-4048-0 Fax ++49-521-4048-4280 Operating Instruction ServiceJunior SensoControl Please read carefully
More informationECT Display Driver Installation for AP2 Module
ECT Display Driver Installation for AP2 Module Overview The ECT Display Driver is a small module with a removable wire harness that mounts behind the driver's foot well cover. All wiring connections are
More informationInstallation and Operations Manual
Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water
More informationPowerView PV380-R2 Mechanical Configuration
PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive
More informationDIGITAL TORQUE GAUGE MODEL BTGE-G
DIGITAL TORQUE GAUGE MODEL BTGE-G OPERATING INSTRUCTION BTGE-G BTGE-G Model To use this product properly and safely, please read this manual carefully before use. If you have any question about the product
More informationMPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS
MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS DATASHEET 1. SAFETY The MPT-200A Wire Crimp Pull Tester is a force measurement device, and as such should be operated with due caution. Operator should
More informationRally computer 3 Rally computer 3.GPS *
Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to
More informationUSER MANUAL. ATEQ IONIQ 6 SW 1.01 version. Reference: UM-29100B-U. (Photo non contractual)
USER MANUAL ATEQ IONIQ 6 SW 1.01 ersion (Photo non contractual) Reference: UM-29100B-U Recommendations for electrical test equipment Safety rules for the IONIQ The IONIQ operating and power-up will necessarily
More informationMI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.
Page 1 3/21/2014 MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function. Torches: There are 5 torches total that make up the beveling system. There are two bevel
More informationTTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)
First, Sign and Date Bln 2009-03-9 Updated, Sign and Date Bln 200-04-29 (0) User Manual TTT802 Gearshift Controller Firmware for R--N-2- TTT802 Gearshift Controller, Part # 2-620-9-RN-S (Standard), -P
More informationCannondale Diagnostic Tool Manual
Cannondale Diagnostic Tool Manual For vehicles (ATV & Motorcycles) equipped with the MC1000 Engine Management System Software CD P/N 971-5001983 Data Cable P/N 971-5001984 POTENTIAL HAZARD Running the
More informationUP100AC INSTRUCTION MANUAL
UP100AC AC/DC Charger INSTRUCTION MANUAL 100W 10A TABLE OF CONTENTS Introduction... 2 Special Features... 4 Warning and Safety Notes... 6 Lithium Battery Connection Diagram... 10 Operation Diagram - Homepage...
More informationDKG-509 AUTOMATIC MAINS FAILURE UNIT
DKG-509 AUTOMATIC MAINS FAILURE UNIT CANBUS AND MPU VERSIONS DESCRIPTION The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available
More informationNexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family
NexSysLink CAN Instruments Product Family Operation Manual NMEA 2000 SAE J1939 Indmar Engines Contact Beede Beede Electrical Instrument Company, Inc. 88 Village Street Penacook, NH 03303 (603) 753-6362
More informationModel PRO-9675FT4 Owner's Manual
Model PRO-9675FT4 Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable FEATURES : w 2 Four Button Programmable RF Transmitters w Four Channel Code Learning Receiver
More informationAtlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY
Atlas 5 TM Handheld Indoor Air Quality Monitor Instruction Manual Measures, Temperature and Humidity DISTRIBUTED BY ITRDUCTI Thank you for purchasing this portable meter. This device measures ppm levels,
More informationSiCan Simple CAN Extension Charger to PacMon
SiCan Simple CAN Extension Charger to PacMon Provides and extension charger to PacMon. Drives CAN TC (Elcon) type chargers. Interfaces with the CMon, SiMon, and UMon. Programmable high and low (balance)
More informationTension Control Inverter
Tension Control Inverter MD330 User Manual V0.0 Contents Chapter 1 Overview...1 Chapter 2 Tension Control Principles...2 2.1 Schematic diagram for typical curling tension control...2 2.2 Tension control
More informationITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance
TM ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance Scale Users Guide ISHTAA SCALES INC., INDIA www.ishtaascales.com 14 Content 1. Technical Data... 1 2. Installation... 2 3. Controls
More informationDKG-109 AUTOMATIC MAINS FAILURE UNIT
Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-109 AUTOMATIC MAINS FAILURE UNIT FEATURES Automatic mains failure Engine control Generator protection
More informationMAGPOWR Spyder-Plus-S1 Tension Control
MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,
More informationPulsar EXtreme 2200C / 3200C
www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 00C / 300C Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 3400753EN/AA - Page Introduction Thank you for selecting
More informationQUICK INSTALLATION GUIDE
MANUAL/AUTOMATIC T R A N S M I S S I O N 2 - B U T T O N R E M O T E S T A R T E R W I T H V I R T U A L T A C H S Y S T E M ( A S P R G - 1 0 0 0 C O M P A T I B L E ) QUICK INSTALLATION GUIDE Manual
More informationSUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL
SUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL Specifications and functions of Suzuki Diagnosis System (1) The system diagnoses troubles by communicating with the onboard computer by means of the specially designed
More informationModel TUR-200D Turbine Flowmeter
General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.
More informationThe measurements module provides the following engine features information:
1. INTRODUCTION The CEM6 control board is a monitoring network signal and monitoring and control generator feeding device. The device consists of 2 different modules: - Visualization module. The visualization
More informationThe RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3
The RCS-6V kit Page of Contents Page 1. This Book 1.1. Warning & safety 3 1.2. What can I do with the RCS-kit? 3 1.3. Tips 3 2. The principle of the system 2.1. How the load measurement system works 5
More informationINSTALLATION AND OPERATION INSTRUCTION
INSTALLATION AND OPERATION INSTRUCTION ATi Max 2-1/2-6, 65-150mm Install the ATi Max valve either in the supply or return pipework for the unit. It is recommended that a strainer be installed prior to
More informationELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A
ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationl The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal
Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used
More informationSmartPak Welding Controller WK-MPS-16 Constant Current
SmartPak Welding Controller WK-MPS-16 Constant Current Features Latest state of the art ATMEL 8 bit microprocessor technology Synchronous digital welding control allows absolute precision Up to16 programmers
More informationPositive displacement batch controller
8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total
More informationEXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE
CLEAN MODE Temperature Controller User s manual CURRENT CONDITIONS ROOM TEMPERATURE PROBE TEMPERATURE OUTSIDE TEMPERATURE RELATIVE HUMIDITY STATIC PRESSURE TIME / DATE SETTINGS SET POINT / CURVE MINIMUM
More informationYaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C
Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C710616 32, SIEP C710616 33, and SIEP C710616 38 Introduction This supplement to the L1000A Technical Manual describes features
More informationPCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business
More informationPIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description
PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple
More informationPressing and holding the + RES switch, when the Cruise Control System is engaged, will allow the vehicle to
CRUISE CONTROL DESCRIPTION AN... CRUISE CONTROL DESCRIPTION AND OPERATION (CRUISE CONTROL) Document ID# 2088041 Cruise Control Description and Operation Cruise control is a speed control system that maintains
More informationUser Manual. Compact Tester II st Edition
User Manual Compact Tester II 446 300 430 0 1st Edition This publication is not subject to any update service. You will find the new version in INFORM under www.wabco-auto.com Copyright WABCO 2006 Vehicle
More informationOWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1
OWNERS MANUAL iforks Rev.18.02.09 OWNERS MANUAL iforks 1 PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE If you have any queries concerning the duration and terms of the guarantee, please contact
More informationSmart Wi-Fi Sprinkler Timer and Flow Meters
Smart Wi-Fi Sprinkler Timer and Flow Meters User s Manual Welcome to H2OPro Thank you for purchasing the H2OPro. The H2OPro is a sprinkler timer with a Wi-Fi interface. The system provides sprinkler valve
More informationForce and Torque testing equipments
EDITION NO. 4 Force and Torque testing equipments Measuring force from Apple to Zipper since 1960 Measuring force from Apple to Zipper since 1960 COM-TEN INDUSTRIES PROVIDES: Over 45 years of experience
More informationCOUNTIS E22 Three-phase energy meter Direct - 80 A
Instruction manual COUNTIS E22 Three-phase energy meter Direct - 80 A EN www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings... 4 2.1. Risk of electrocution, burns
More informationModel PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable
Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable FEATURES:! 2 Four Button Programmable RF Transmitters! Four Channel Code Learning Receiver
More informationPCS GEAR SELECT MODULE USER GUIDE v4.0
PCS GEAR SELECT MODULE USER GUIDE v4.0 Ph: 1.804.227.3023 www.powertraincontrolsolutions.com Powertrain Control Solutions 1 Introduction 1.1 Included Components 1 - GSM Cable Motor Enclosur 1 - GSM Driver
More informationU n i n t e r r u p t i b l e P o w e r S y s t e m
SMART ON-LINE UPS User s Manual U n i n t e r r u p t i b l e P o w e r S y s t e m Smart On-Line UPS 2KVA ~ 20KVA 20KVA Exhaust hole (16)Main breaker (12)Heat exhaust hole (15)Telephone (Rj11) or network
More informationModel: APS-610a Owner s Manual 4 Button Remote Security System with Dual Stage Shock Sensor
Model: APS-610a Owner s Manual 4 Button Remote Security System with Dual Stage Shock Sensor IMPORTANT! In order to provide the highest possible level of security to your vehicle, this system is equipped
More informationTWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING
TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER User Guide WARNING It is the responsibility of the vehicle operator to ensure their vehicle is parked in a safe and responsible manner. 1. When leaving the
More informationX11CA-IM MASTER MODULE
X11CA-IM MASTER MODULE (Firmware: X11-MF3 Rev. 3) REVISION : 2.0 DOCUMENT NUMBER : X11CA-3000-IOM DATE : April 21, 2003 EDITOR : Nana Lee Ronan Engineering Company APPROVED : Kevin Safayieh 4/23/03 Project
More informationQuick Installation Guide for X50 Plus Car OBD Multi-function instrument Product introductions
Quick Installation Guide for X50 Plus Car OBD Multi-function instrument Product introductions Appropriate models for products The product is suitable for standard OBD-II protocol compliant petrol and diesel
More informationTABLE OF CONTENTS General information... 4 Benefits of the system... 4 OPERATION CONCEPT... 5 Algorithm of deactivation... 5 Authorization with the
OPERATING MANUAL Dear car owner! Please note that the AUTHOR Alarm s anti-theft devices are not intended for self-installation. We strongly recommend to install and configure the purchased equipment only
More informationBlue Bird Instrumentation Operators Guide
Blue Bird Instrumentation Operators Guide Page 1 I. INTRO Display Windows Menu navigation and option selection is done by pressing the Esc, Select, Up and Down buttons located in the stalk switch control
More informationUsing the Star Tester
Page 1 of 12 Using the Star Tester 1. Turn the ignition key off. 2. Connect the color coded adapter cable to the STAR tester. 3. Connect the adapter cable leads to the proper Self-Test connectors(figure
More informationALFA-Club. Owners Manual Rev 4.0, August Small Systems Specialists 201 N. Lobb Ave. Pen Argyl, PA Memory Checkpoint Clock
ALFA-Club Memory Checkpoint Clock Dual Odometer/Clock Owners Manual Rev 4.0, August 2018 Small Systems Specialists 201 N. Lobb Ave. Pen Argyl, PA 18072 609-301-0541 ALFA@Rally.cc On the web at www.rally.cc
More informationBERMAD Waterworks. Insertion Flow Meter Device (IFM)
IFM-MUT1222PRV BERMAD's IFM-MUT1222-PRV SENSOR is designed for measuring the flow rate of valves sized DN80 to DN600 (3-24 ). This document describes the installation process of the sensor. For larger
More informationINSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH
Instr. No. 2650-887D INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH IMPORTANT WEAR SAFETY GLASSES 5 4 6 COPYRIGHT PATENT PENDING 3 7 8 PLAYBACK 9 2 0 1 AUTO METER PRODUCTS, INC. SYCAMORE, IL
More informationOwners Manual for TPMS plus GPS
To ensure correct operation and service please read these instructions before installing and operating the TPMS feature of the TPMS/GPS unit. Owners Manual for TPMS plus GPS TABLE OF CONTENTS TIRE PRESSURE
More information" MANUALLY OVERRIDING YOUR SYSTEM
Model PRO 2000aS Owner s Manual 3 Button Remote Security System with Keyless Entry IMPORTANT! In order to provide the highest possible level of security to your vehicle, this system is equipped with selectable
More informationDIESEL Engine Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationFOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL USA (815) us at
2650-887F INSTALLATION INSTRUCTIONS 5 single channel ultimate tach COPYRIGHT PATENT 5 4 6 3 PENDING 7 8 PLAYBACK 9 2 0 1 AUTO METER PRODUCTS, INC. SYCAMORE, IL USA MADE R P M X1000 IN USA ENTER START PAUSE
More informationLingenfelter NCC-002 Nitrous Control Center Quick Setup Guide
Introduction: Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide The NCC-002 is capable of controlling two stages of progressive nitrous and fuel. If the NCC-002 is configured only for nitrous,
More informationHGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic
HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...
More informationACTUATORS POSITION SENSOR
POSITION SENSOR 1 2 SUMMARY P INTRODUCTION PAGE 4 P LTS POSITION SENSOR PAGE 5 P LTL POSITION SENSOR PAGE 9 SUMMARY P LTE POSITION SENSOR PAGE 12 3 INTRODUCTION INTRODUCTION Magnetic position sensors are
More informationTWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING
TWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER User Guide WARNING It is the responsibility of the vehicle operator to ensure their vehicle is parked in a safe and responsible manner. 1. a)
More informationWeighing Scale IDS-802. User Manual
Weighing Scale IDS-802 User Manual A. MAIN SPECIFICATION Model: Capacity: Accuracy: Display: IDS-802 Weighing scale 3kgx0.1g,6kgx0.2g,15kgx0.5g,30kgx1g Grade III, n=30,000 Single 6 digits LCD with Blue
More informationDynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.
1993-2001 Dynojet Research, Inc. All Rights Reserved.. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software
More informationPCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS
PCT plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS Ver. DESCRIPTION The PCT plus is a pressure controller for refrigeration plants that require control in their suction and discharge stages. With
More informationSNMP dedicated to ORVALDI Solar Infini
SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation
More information