Below is quick summary of the pumping capabilities of each alternative:
|
|
- Stella Gregory
- 5 years ago
- Views:
Transcription
1 Memorandum June 8, 17 To: From: cc: Re: Michael Bumbaco, City of Virginia Beach Scott Morrow, Hazen and Sawyer Emiliee Auyang-Jessen, City of Virginia Beach Mark Jones, City of Virginia Beach North Sherwood Lake Pump Station Preliminary Concept Alternatives Please find attached the three alternatives for the permanent and temporary pumping solutions at North Sherwood Lake. For all alternatives, the 12 temporary trailer mounted pump is shown connecting to an above ground suction and discharge flanged elbow. The suction line extends into the proposed permanent wet well with it s own bay within the wet well structure. The discharge line extends to back of property and heads south towards asphalt path of development. The permanent pump solutions within the wet well will have their discharge piping connect to the shared discharge force main. The A and B alternatives for each layout show the permanent discharge piping/valves in a valve vault (A) or above ground (B). This configuration will be an option based on preference of Operations and site layout constraints. All layouts will have the same 36 RCP influent line from the lake to the wet well. Below is quick summary of the pumping capabilities of each alternative: Alternative 1: (2) 25 hp submersible pumps ( Flygt NP 3171 LT utilized as basis of design) 1 pump operation: o 5 cfs operating point with temporary pump operating simultaneously o 8 cfs operating point without temporary pump 12 temporary pump can achieve 13 cfs maximum operating point with and without permanent pumps operating. A throttling valve will be required on the discharge of the temporary pump to ensure pump is operating on pump curve. Maximum combined pumping capacity of 18 cfs with temporary pump operating. 18 discharge force main 25 x 35 fenced in concrete slab area Alternative 2: (3) 25 hp submersible pumps ( Flygt NP 3171 LT utilized as basis of design - same as alternative 1 pump) 2 pump operation: o 6.5 cfs operating point with temporary pump operating simultaneously o 11.5 cfs operating point without temporary pump 12 temporary pump can achieve 13 cfs maximum operating point with and without permanent pumps operating. A throttling valve will be required on the discharge of the temporary pump to ensure pump is operating on pump curve. Hazen and Sawyer 2809 S. Lynnhaven Road, Suite 350 Virginia Beach, VA
2 June 8, 17 Maximum combined pumping capacity of 19.5 cfs with temporary pump operating. 18 discharge force main 25 x 35 fenced in concrete slab area Alternative 3: (3) 35 hp submersible pumps (12 Flygt NP 32 LT utilized as basis of design) 2 pump operation: o 18.3 cfs operating point without temp pump o 13.5 cfs operating point with temp pump 1 pump operation: o 12.0 cfs operating point without temp pump o 9.5 cfs operating point with temp pump 12 temporary pump would only be utilized in event of an emergency. The permanent pumps with 2 in operation can provide the required 18 cfs maximum capacity of the station. Maximum combined pumping capacity of 26.5 cfs with 2 pumps and temporary pump operating. discharge force main 30 x 40 fenced in concrete slab area Please do not hesitate to contact me with any questions or concerns regarding the project and the attached preliminary pump station concept alternatives. North Sherwood Lake Pump Station Preliminary Concept Alternatives Page 2
3 ALTERNATIVE 3 30' " DI FM SHADOW BO 40' File = O:\315-HRD\315 - PWCN C\315-03C - Sherwood Lake\CAD-BIM\MISC\FIGURES\17-06\Figure 1 - Pump Layout-REV Saved by smorrow Save date = 6/16/17 :19 AM WET WELL (15'x18') W/ (3) 35 HP SUBMERSIBLE PUM (18 CFS W/ 2 PUM) EPANSION REPLACE E INLETS SCALE: 1" = ' 0 '
4 ALTERNATIVE 2 25' 18" DI FM SHADOW BO 35' File = O:\315-HRD\315 - PWCN C\315-03C - Sherwood Lake\CAD-BIM\MISC\FIGURES\17-06\Figure 1 - Pump Layout-REV Saved by smorrow Save date = 6/16/17 :19 AM WET WELL (12.5'x15.0') W/ (3) 25 HP SUBMERSIBLE PUM (12 CFS W/ 2 PUM) EPANSION REPLACE E INLETS SCALE: 1" = ' 0 '
5 ALTERNATIVE 1 25' 18" DI FM SHADOW BO 35' File = O:\315-HRD\315 - PWCN C\315-03C - Sherwood Lake\CAD-BIM\MISC\FIGURES\17-06\Figure 1 - Pump Layout-REV Saved by smorrow Save date = 6/16/17 : AM WET WELL (11.5'x12.5') W/ (2) 25 HP SUBMERSIBLE PUM (5 CFS) EPANSION REPLACE E INLETS SCALE: 1" = ' 0 '
Flygt N-Pumps 3085, 3102 & 3127
Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The ConCepT Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life
More informationBypass Pumping Brian Lee Municipal Sales Rev Bypass Pumping
Bypass Pumping Brian Lee Municipal Sales Rev. 2018 1 Bypass Pumping 2 1 Bypass Pumping 3 Bypass Pumping 2 Bypass Pumping Bypass Pumping 6 3 Topics Covered Definition of bypass Evaluation of an application
More informationSchedule 18 (Technical Requirements) DBFO Agreement EXECUTION VERSION APPENDIX B - SELECT DEPARTMENT STANDARD DRAWINGS AND REFERENCE TABLES
Schedule (Technical Requirements) DBFO Agreement EXECUTION VERSION APPENDIX B - SELECT DEPARTMENT STANDARD DRAWINGS AND REFERENCE TABLES Schedule (Technical Requirements) DBFO Agreement EXECUTION VERSION
More informationITT FLYGT ORIGINAL O-RING/INTERMEDIATE SERVICE KITS
ITT FLYGT ORIGINAL O-RING/INTERMEDIATE SERVICE KITS O-RING KITS / INTERMEDIATE SERVICE KITS Quality products deserve genuine spare parts. ITT Flygt pumps and mixers work best with genuine ITT Flygt spare
More informationCity of St. Pete Beach Model Capacity Report Addendum
Model Capacity Report - Addendum City of St. Pete Beach Model Capacity Report Addendum Prepared for: City of St. Pete Beach 155 Corey Avenue St. Pete Beach, FL 33706 Prepared By: Kimley-Horn and Associates,
More informationTransmission Improvements Plan for 575 MW Network Service Request Wansley CC 7 Generation Facility (OASIS # ) Georgia Transmission Corporation
Transmission Improvements Plan for 575 MW Network Service Request CC 7 Generation Facility (OASIS # 143556) Georgia Transmission Corporation November 11, 2010 CC7 TIP 11-11-2010 (2).docx PROBLEM STATEMENT
More informationTECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.
Page 1 of Telephone: 29-95-9501 Technical Services: 877-38-5 Fax: 29-818-180 Email: techsvcs@vikingcorp.com 1. GENERAL DESCRIPTION The Halar Coated Concentrate Control (CCV) is utilized in Viking foam
More informationMEMORANDUM. TO: Board of Directors DATE: November 18, 2016
MEMORANDUM TO: Board of Directors DATE: November 18, 2016 FROM: SUBJECT: Rich Kissee October Ops Update SUMMARY: Water Systems and Mechanical Crews CWRP Ordered and installed the new piping for the new
More informationRolling Road (Route 638) Widening Project
Rolling Road (Route 638) Widening Project From: 0.369 Mile North of Fairfax County Parkway (Route 286) To: Old Keene Mill Road (Route 644) State Project No. 0638-029-156, P104, R204, C504; UPC 5559 Public
More informationMarket Update Note. EcoEGR coming to your Tier III engine soon MUN
MUN2018-02-07 EcoEGR coming to your Tier III engine soon MAN B&W two-stroke diesel engines use selective catalytic reduction (SCR) or exhaust gas recirculation (EGR) to comply with IMO Tier III requirements.
More informationABL FIRE PROTECTION RALEIGH, NORTH CAROLINA
ABL FIRE PROTECTION RALEIGH, NORTH CAROLINA Job Name : Building : TOWER Location : 4501 CREEDMOOR ROAD RALEIGH NORTH CAROLINA System : 16-1TH FLOOR Contract : Data File : SOLEIL 16-1.WXF ABL FIRE PROTECTION
More informationTechnical Memorandum. To: From: Date: October 14 th, 2018 Project #: 1302 Project Name: Subject: Distribution:
Technical Memorandum To: Tom Hanrahan Jeff Sharp From: Date: October 14 th, 2018 Project #: 1302 Project Name: Subject: Distribution: Barrie Lockhart Road LP Conformity Review Scott Young Sorbara Group
More informationABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC
ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC 919-835-2225 Job Name : Building : TOWER Location : 4501 CREEDMOOR DR RALEIGH NORTH CAROLINA System : 18TH-2 FLR Contract : Data File : SOLEIL 18-2TH.WXF
More informationIntroducing the new Steady Flygt 1300 series. Power to go
Introducing the new Steady Flygt 13 series Power to go Steady performance Steady Flygt 13 is a new series of submersible pumps that deliver top-level performance at outstanding value. The Steady Flygt
More informationSUBTOTAL SITE WORK & DEMOLITION (UTILITIES) $180, $348, $319,943.71
BASE BID 1.00 GENERAL CONDITIONS 1.01 Mobilization (Maximum 5% of Base Bid) LS 1 84,000.00 $ 84,000.00 100,000.00 $ 100,000.00 85,000.00 $ 85,000.00 1.02 Bonding, Insurance, Permits (including Plumbing,
More informationTRAFFIC ENGINEERING DIVISION INSTRUCTIONAL & INFORMATIONAL MEMORANDUM
VIRGINIA DEPARTMENT OF TRANSPORTATION TRAFFIC ENGINEERING DIVISION INSTRUCTIONAL & INFORMATIONAL MEMORANDUM GENERAL SUBJECT: Portable Temporary Rumble Strips (PTRS) SPECIFIC SUBJECT: Guidelines for the
More informationCITY OF STANDARD SPECIFICATIONS
CITY OF Published May 4, 2016 CALIFORNIA Stephan Kiefer, Community Development Director Cheri Sheets, City Engineer CITY OF LIVERMORE 1052 South Livermore Avenue Livermore, CA 94550 4DEV0001.doc 03/12
More informationDATE: MAY 3, 2007 ENVIRONMENTAL MANAGEMENT DIVISION
DATE: MAY 3, 2007 FROM: ENVIRONMENTAL MANAGEMENT DIVISION SUMMARY: This Board item requests that the Board of Harbor Commissioners approve the allocation and expenditure, from funds previously disbursed
More informationABS submersible sewage pump AFP
BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance
More informationCITY OF DAVIS PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS
CITY OF DAVIS PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS JANUARY 1996 EDITION ADDENDA THROUGH JULY 2017 DIANNA JENSEN City Engineer 1717 Fifth Street Davis, CA 95616 530-757-5686 2017 Edition STANDARD
More informationDRS. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE /A40-115-1.1M, /A40-140-1.1M, /A40-136-1.1M, /A40-150-1.8M 203 PERFORMANCE CURVE /A40-136-1.4,
More informationRAS & WAS Pumps (FLYGT Pump)
RAS/WAS Pumping Pumping of sludge from the secondary clarifiers to the aeration tanks maintains active biomass in the aeration tanks This is referred to as return activated sludge (RAS) pumping RAS pumps
More informationPublic Information Centre
Junction Street Wastewater Pumping Station & Forcemain Schedule B Municipal Class Environmental Assessment Study Public Information Centre June 28, 2017. 6:00 to 8:00 pm. The Burlington Performing Arts
More informationLEGAL DESCRIPTION REZONE PARCEL
Certco, Inc. 5321 Verona Road Madison, WI 53711 LEGAL DESCRIPTION REZONE PARCEL A part of the Southwest Quarter of the Southwest Quarter of Section 05, Township 06 North, Range 09 East, City of Fitchburg,
More informationSubmersible Stainless Steel Semi-Vortex Pumps Pumps
Technical Data Right Submersible Stainless Steel Semi-Vortex Pumps Pumps EBARA PUMPS AUSTRALIA PTY. LTD. DWVOX_Techdata_SS_ Right_Techdata_DS_ CONTENTS -SPECIFICATIONS Page Features & Applications 100
More information50TH STREET CONCEPTUAL DESIGN
NUE NUE NUE 51 AVE REET 5.49 A-A SECTION 50TH STREET - STA 0+560 1.2 33.46 19.10 8.75 1.00 3.00 3.00 1.00 CN SPUR IF NECESSARY, GRADING ON PRIVATE TO BE BUS STOP 3697 IVE IVE BUS STOP 2279 4.25 REET REMOVE
More informationFlygt 3153, 50Hz. Technical Specification
Flygt 3153, 5Hz Technical Specification Table of Contents Table of Contents F-pump, Standard Motor... Product description... Motor rating and performance curves...4 F-pump, Premium Efficiency Motor (IE3)...
More informationAppendix Technical Memorandum PS-1 on Pumping Stations Condition Assessment
Appendix 4-28 Technical Memorandum PS-1 on Pumping Stations Condition Assessment TECHNICAL MEMORANDUM PS-1 March 8, 2013 To Copy to From Town of Falmouth, MA File; Project Team Nathan C. Weeks, P.E., BCEE
More informationCNG FUELING STATION INITIAL STUDY FULLERTON JOINT UNION HIGH SCHOOL DISTRICT. Appendices
CNG FUELING STATION INITIAL STUDY FULLERTON JOINT UNION HIGH SCHOOL DISTRICT Appendices Appendix F Parking Study April 2016 CNG FUELING STATION INITIAL STUDY FULLERTON JOINT UNION HIGH SCHOOL DISTRICT
More informationCOUNTY DIVISIBLE LOAD PERMITS ISSUED IN 2013 PERMIT FEES PERMITS?
COUNTY DIVISIBLE LOAD PERMITS ISSUED IN 2013 PERMIT FEES PERMITS? GARFIELD NO Single OS - 57 Single Trip OS $15.00 Single OW - 710 Single Trip OW $15.00 + $5.00/axle Single OS/OW - 798 Annual OS $250.00
More informationPublic Works & Utilities Department Memorandum
Public Works & Utilities Department Memorandum To: Land Development Owners, Engineers, and Contractors From: Public Works and Utilities Date: March 21, 2016 Subject: Solid Waste Facilities The information
More informationCP #CP218 NAIL SOFT GROUND N= E= ELEV= GUY WIRE. + WV CP #CP175 Old Magnail N= E= ELEV=858.
O R IG IN A T O R : C IT Y OF M A D IS O N, S T R E E T S DIV IS IO N 805 4906 802 813 4910 821 825 DELAWARE LN 1 2 3 EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY OTHER CONSTRUCTION ACTIVITY
More informationBIDDER'S PROPOSAL (continued) CITY OF BERKELEY BID PROPOSAL ITEM NO. A: BASE BID
SPECIFICATION 16-11031-C CITY OF BERKELEY BID PROPOSAL A: BASE BID 1 MOBILIZATION 1 LS 2 TRAFFIC CONTROL 1 LS 3 CONTRACTOR INFORMATION SIGN 2 EA 4 CONSTRUCTION AREA SIGN 18 EA 5 PROJECT IDENTIFICATION
More informationUBC Watermain as shown on Sheet 202 : Sub total 97,050
Preliminary Cost Estimate Brock Commons Phase 1 Watermain replacement UBC Portion of Works only Replace existing 150mm dia CI and 200mm dia AC watermain with 200mm & 250mm dia DI (ductile iron) watermain
More informationOrdering Code of 2PBA Pumps
Ordering Code of 2PBA Pumps Pump Code 3 Displacement ( cm ) Direction of Version Sealing Inlet Fittings 2PBA 18 L S N A A Suction Fittings Included N Nitrile V Viton S Special Version C Classic Version
More informationA-C Fire Pump. Fitting and Accessories A-C 100A
A-C Fire Pump Fitting and Accessories A-C 100A A-C Fire Pump Fitting and Accessories Table of Content Page Automatic Air Release Valve... 1 Suction And Discharge Gauge Assembly... 2 Casing Relief Valve...
More informationMEMORANDUM. Project Description. Operational Trip Generation. Construction Trip Generation. Date: August 12, 2014 TG: To: From: Subject:
MEMORANDUM Date: August 12, 2014 TG: 13329.01 To: From: Subject: Jeremy Krout EPD Solutions Inc. Rafik Albert EPD Solutions Inc. Rawad Hani Transpo Group AP North Lake Solar Project Traffic Scoping The
More informationSeries MRK and MRM For nominal pressures up to 640 bar /class 4500 Automatic Recirculation Valve for pump protection
Series MRK and MRM For nominal pressures up to 640 bar /class 4500 Automatic Recirculation Valve for pump protection Series MRK and MRM The ultimate high pressure SCHROEDAHL Automatic Recirculation Valve,
More informationAppendix C Capital Improvement Program Project Descriptions and Details
Appendix C Capital Improvement Program Project Descriptions and Details GIG HARBOR WW COMP PLAN DRAFT CAPITAL IMPROVEMENT PROGRAM LIFT STATION COST ESTIMATE Lift Station 1 Item Qty Units Unit Cost Extended
More informationADDENDUM #1 NWIT Watermain Replacement Program New Westminster, BC
June 20, 207 ADDENDUM # NWIT723 207 Watermain Replacement Program New Westminster, BC This addendum modifies the Invitation to Tender only as noted: INSTRUCTIONS TO TENDERERS PART I 3.0 Submission of Tenders
More informationMulti-Tank Submersible Pump Install Manual
Multi-Tank Submersible Pump Install Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011
More informationIPH Series Double IP Pump
IPH SERIES DOUBLE IP PUMP IPH Series Double IP Pump 3.6 to 125.9cm 3 /rev 3MPa ll the types in this new design (11D) series are installation compatible with the previous design (1D). Note, however, that
More informationWeights: Motor... Lb Pump... Lb Extra Column... Lb
Peerless Pump Company Electric Motor Driven Pump Unit Outline Dimensions 8MAF 250 GPM SECTION 1630 Page 1 December 18, 1998 Notes: 1 This drawing describes sump installation, above ground discharge head
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationStandards for Design and Construction
Standards for Design and Construction Of Water, Wastewater, Fiber optics and Reclaimed Water Facilities For Pasco County Utilities Department Revised: March 2018 Board of County Commissioners: Kathryn
More informationTanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump
Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump Granby Fire Department Granby, Massachusetts The Tanker Granby FD s Tanker 1 is a 5,000-gallon tanker that is outfitted with an 8-inch rear
More informationValve and Piping Replacements. Deer Island Treatment Plant
Massachusetts Water Resources Authority Valve and Piping Replacements Deer Island Treatment Plant (MWRA Contract 7275) September 10, 2014 Contract 7275 Summary Contractor: Carlin Construction Company Contract
More informationGRUNDFOS PRICE LIST 2017 WASTEWATER. Effective date: January 1, 2017
GRUNDFOS PRICE LIST 2017 WASTEWATER 2017 Effective date: January 1, 2017 TABLE OF CONTENTS WASTEWATER SMALL AND LARGE PUMPS, CONTROLS & ACCESSORIES WASTEWATER LARGE SEG Type Key...4-1 SEG Submersible Grinder
More information2, total unit $ total unit $ total unit $ total $
BD TABULATON Bid No. : 697 North Bay Trail-1st Street North Project No. 0901-212 Engineering &Capital mprovements Department, City of 1. Petersburg, Florida Bid date: February 26,2010 ",,>,',-, t~..4":;
More informationATTACHMENT #1. TO: Patricia delabruere DATE: May 5, 2015 JNU Airport Manager
MEMO TO: Patricia delabruere DATE: May 5, 2015 JNU Airport Manager FROM: RE: Catherine Fritz, AIA JNU Airport Architect ARFF Project Formulation The Airport Board s funding authorization on February 11,
More informationPure Performance FLYGT 1300 SERIES
Pure Performance FLYGT 1300 SERIES Available EASY TO SELECT, QUICK DELIVERY, THE RIGHT PUMP FOR YOUR NEEDS Oustanding Value EFFICIENT, POWERFUL Reliable SOLIDS HANDLING, CONTINUOUS RUNNING 2 Readily available
More information+GF+ CLASS 267. Factory Mutual Approved. HDPE Pipe & Pipe Fittings GEORG FISCHER PIPING SYSTEMS centralplastics.
Factory Mutual Approved CLASS 26 HDPE Pipe & Pipe Fittings CENTRAL PLASTICS 8.499.692 Table Of Contents 18-1 Design-Flow HDPE IPS HDPE Pipe (Iron Pipe ) 4-24 18-2 PE 368 HDPE Physical Properties - FM 18-3
More informationBERMAD BERMAD BERMAD WW M
Surge Anticipating Control Valve with Solenoid Control Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise
More informationHigh Purity PTFE Pumps
HIGH FLOW / COMPACT DESIGN High Purity PTFE Pumps WWW.YAMADAPUMP.COM Table of Contents DP-C20F.3 DP-C25F.4 DP-C38F.5 DP-Fi.6 NDP-BTT.7 Pulsation Dampeners...8 Electro-Polished Pumps..9 Electro-Polished
More informationMidwest Roadside Safety Facility
24" 609 Asphalt Impact 3/1 [1300] upstream from upstream end of permanent barrier B 166'-10 1/1 50853 25 Plan View 3/1 1300 3 813 Free-Standing Kansas Barriers Kansas Barrier With 2 Asphalt Stakes Per
More informationTerminal Alternatives
Chapter 5 Terminal Alternatives Missoula International Airport Master Plan Update Prepared for Missoula County Airport Authority OCTOBER 2008 Contents Section Page 5 Terminal Alternatives...5-1 5.1 Terminal
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE BEST 2 203 PERFORMANCE CURVE BEST 3 203 PERFORMANCE CURVE BEST 4 203 PERFORMANCE CURVE BEST
More informationSECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS
SECTION 15160 - PUMPS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationSelection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY
Selection Chart Project: Model: Chk d: Date: 45 (Ft) (m) 15.0 HZ (Synchronous Speed - 1800 RPM) 35 C2905-7 25.0 8.0 C1125-17 C15-1170 C2185-885 7.0 TOTAL HEAD 15 6.0 5.0 C1455-1170 V0494-1170 V0554-1170
More informationNeighborhood Fire Stations
Department of Public Works EARTHQUAKE SAFETY AND EMERGENCY RESPONSE BOND Neighborhood Fire Stations Projects Update Presentation to the SF Fire Commission August 22, 2013 Agenda ESER 1 Project Locations
More informationCGUII/CGFU. Model CGUII/CGFU Contents. EBARA PRO Cast Grinder Pumps. Model 32CGUII61.5S
Model Contents Model 3CGUII6.5S 3CGFU6.5S 3CGFU6.5 5CGFU6.S 5CGFU6. 5CGFU63.7S 5CGFU63.7 Section Page Specifications 8 Selection Chart 83 Performance Curves 86 Dimensions 88 Sectional View 83 QDC Information
More informationPROCESS PUMPS (INDIA) PVT LTD
VERTICAL CANTILEVER SHAFT SUMP PUMP (PPCS)_ METALLIC INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area, Bangalore 560058 Phone:
More informationMemorandum. This memorandum requires Board action. EXECUTIVE SUMMARY
California Independent System Operator Memorandum To: ISO Operations (MRTU) Committee From: Armando J. Perez, Director of Grid Planning cc: ISO Board of Governors ISO Officers Date: April 29, 2005 Re:
More informationINDUSTRIAL SPACE FOR LEASE 4050 PATRIOT DR., DURHAM, NC 27703
50 PATRIOT R., URHAM, NC 27703 PARK SITE PLAN PATRIOT RIVE BUILING 2 Road Proposed BUILING 2 X 680 = 63,200 SF BUILING 2 2 X 665 = 59,600 SF STREET B STREET A STREET A BUILING 4 20 X 750 = 57,500 SF LOT
More informationGEAR PUMPS DIMENSIONAL DETAILS
DIMENSIONAL DETAILS OUTLET INLET TYPE DISPLACEMENT CM 3 /REV FLOW AT 1500 REV/MIN MAX. WORKING PRESSURE MAX. SPEED DIMENSIONS MM P1 P2 P3 RPM L M D2 1.4 2.0 270 290 310 6000 40 79 D3 2.1 2.9 270 290 310
More informationTurbocharger Compressor Calculations
Turbocharger Compressor Calculations Introduction The purpose of this little paper is to show the reader how to calculate the volume and mass of air moving through his engine, and how to size a turbochargers'
More informationGCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887
GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887 Phone: (978) 657-9714 Fax: (978) 657-7915 December 31,2.012 Mr. Charles Aspinwall Town
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE RIGHT PERFORMANCE CURVE RIGHT
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 75 204 PERFORMANCE CURVE 100 205 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 BEARINGS 301 MECHANICAL
More informationARIZONA DEPARTMENT OF TRANSPORTATION INFRASTRUCTURE DELIVERY AND OPERATIONS DIVISION CONTRACTS AND SPECIFICATIONS SECTION TABULATION OF BIDS
ARIZONA DEPARTMENT OF TRANSPORTATION INFRASTRUCTURE DELIVERY AND OPERATIONS DIVISION CONTRACTS AND SPECIFICATIONS SECTION TABULATION OF BIDS CONTRACT # 2016153 TRACS No. Project No. County District Gross
More informationFluid Dispensing Systems
Fluid Dispensing Systems Automotive Commercial Industrial Diesel Exhaust Fluid (DEF) Open Systems Drum and Tote Packages Lever Pump System EPDM seals for maximum chemical compatibility. Includes 1300-028
More informationSPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER
6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, Email: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 2403SRM10 24V 0.5A MEDICAL
More informationSPECIFICATIONS LOW COST 2404S CHARGER
6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS LOW COST 2404S CHARGER Totally
More informationPARTS LIST PUMPS SLC1 - SLC2 - SLC3
P.L. : 1004-A01 Effective November 2014 Replaces June 2014 PARTS LIST PUMPS SLC1 - SLC2 - SLC3 Keep this parts lists with Installation, Operation and Maintenance Instructions. To order the required spare
More informationInstallation manual. Exhaust system. Marine engines DI09, DI13, DI16. 02:04 Issue 9.0 en-gb. Scania CV AB 2017, Sweden
Installation manual Exhaust system Marine engines DI09, DI13, DI16 333 380 02:04 Issue 9.0 en-gb Changes from the previous issue...3 Important data... 30 Sound reduction...3 Exhaust noise... 3 Exhaust
More information20 DREXEL DRIVE, BAY SHORE, NY 11706, USA Phone: (631) / Fax: (631)
20 DREXEL DRIVE, BAY SHORE, NY 11706, USA Phone: (631) 273 4940 / Fax: (631) 273 5018 Email: gnyequip@gnyequipment.com www.gnyequipment.com 3/16 uncoated Stainless Steel (Grounded to Arm) ..up to 36 GNY
More informationSchematic Layout Development
Schematic Layout Development Northeast Hangar Area Manassas Regional Airport Manassas, Virginia November 2015 Introduction In response to the continuing development demand at Manassas Regional Airport,
More informationPerformance Based Design for Bridge Piers Impacted by Heavy Trucks
Performance Based Design for Bridge Piers Impacted by Heavy Trucks Anil K. Agrawal, Ph.D., P.E., Ran Cao and Xiaochen Xu The City College of New York, New York, NY Sherif El-Tawil, Ph.D. University of
More informationSANITARY SCHEDULE ALIGNMENT CODES: 'ES'= EAU CLAIRE AVENUE SB UTILITY REPLACEMENT WITH STREET RESURFACING - 2015 PROJECT NO. 53W1793 EAU CLAIRE AVE SANITARY SEWER SCHEDULE SHEET NO. U-6 CITY OF MADISON
More informationJDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:
Table of Contents Project: Model: Chk d: Date: Model JCSN 2JCSN2 (2 HP) 3JCSN2 (2 HP) 3JCSNY2 (2 HP) 3JCSN3 (3 HP) 3JCSNY3 (3 HP) 3JCSN ( HP) 3JCSNY ( HP) 3JCSN7 (7. HP) 3JCSNY7 (7. HP) 3JCSN1 (1 HP) 3JCSNY1
More informationContents Project: Model: Chk d: Date:
Contents Model DSHU6. DSHU6.7 DSHU6. DSU6. DSHU6. DSU6.7 DSHU6.7 8DSU6. 8DSHU6. 8DSU6.7 8DSHU6.7 DSU6. DSU67. Section Page Specifications -7, 8 Selection Chart -7., 8. Performance Curves -6 Outline Drawings
More informationTemporary Sales Trailer Application
Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Temporary Sales Trailer Application General: Requests for temporary sales trailers, which comply with
More informationS0300-BV-CAT-020 VACUUM PUMP/SKIMMER SYSTEM. System - P Vaccuum Pump/Skimmer System P /12/2018 9:00:21 AM
Vaccuum Pump/Skimmer System P18100 Page 1 The Vacuum Pump/Skimmer System P18100 is a stationary vacuum pump specifically developed for oil spill countermeasures. The system uses a vacuum pump to provide
More informationDESCRIPTION QUANTITY PRICE TOTAL
GENERAL 1 TRAFFIC CONTROL LS 1 $40,000 $40,000 $8,500.00 $8,500.00 $5,000.00 $5,000.00 $5,000.00 $5,000.00 $15,000.00 $15,000.00 2 MOBILIZATION LS 1 $557,000 $557,000 $629,500.00 $629,500.00 $350,000.00
More informationAdd a proven Danuser attachment to your fleet!
www.danuser.com AUGER BUCKET Eliminates backbreaking labor from mixing, transporting, and dispensing Concrete (up to 1" slump) Sand Washed Gravel (3/4" max.) Wildlife Feed Asphalt Agricultural Grains Reach
More informationFigs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type.
Indicator Posts Indicator posts are controls, extending aboveground, for operating underground sprinkler system valves. As an important feature of their design, a target or indicator, visible through an
More informationSECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS
SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationTECHNICAL INFORMATION Bulletin
Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE BEST 2 203 PERFORMANCE CURVE BEST 3 204 PERFORMANCE CURVE BEST 4 205
More informationDSC3/DSCA3, DSZ3. EBARA Submersible Sewage and Propeller Pumps. Technical Data Contents Project: Model: Chk d: Date:
Technical Data Contents Section Page Motor Protection 3-238 Thrust Bearing Thermal Protection 3-239 Leakage Detector 3-20 Cable Entry 3-21 Cable Connector 3-21.1 Mechanical Seal Sectional DWG 3-22 Mechanical
More informationSTANDARD DRAWING INDEX
ATTACHMENT B STANDARD DRAWING INDEX DESCRIPTION EXISTING DRAWING NO. GENERAL Typical Layout for Improvement Plans City of Stockton Standard Border and Title Block for 8 1/2 x11 Sheet City of Stockton Standard
More informationAPPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties
Appendix D - Proprietary Components (1/9) APPENDIX D D.1 Macalloy Bars Bar dia. mm Stressing ties Stainless steel stressing ties Stainless steel architectural ties High strength Tie rods grades precision
More information4.2 Series Station Option Description
4.2 Series Station Option Description The series station proposal features a new set of side platforms constructed approximately 250 feet north of the existing platforms. The two new platforms would extend
More informationTYPE CERTIFICATE DATA SHEET NO. E1CE
DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION Revision 17 CONTINENTAL IO-360-A, -B, -C, -D, -E, -G, -H, -J, -K, -AB, AF, -DB, -GB,-HB, -JB, -KB, -ES TYPE CERTIFICATE DATA SHEET NO. January
More informationKW Submersible, Single-Vane Impeller
Sewage Pumps KW Submersible, Single-Vane Impeller Performance Curve Total Head (FT) Up to 2 Solids-Handling Heavy-Duty, Silicon Carbide Seals Stainless Steel Keyed Shaft Flows to 325 GPM / Heads to 95
More informationApplication Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification
Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description
More informationDUAL NO BOOM & CENTER DF NOZZLE
180 Lake Ave North Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING DUAL NO BOOM & CENTER DF NOZZLE Part Number SSBK-3TDNB Rev 3 Aug. 2014 Note: Do not return product
More informationRequest for City Commission Agenda
Item # Request for City Commission Agenda Agenda Date Requested: August 5, 2014 (a.k.a. Facesheet) Contact Person: Description: Charles DaBrusco, P.E, Director Environmental Services Request to purchase
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 407 Rev. T Model E Alarm Check Valve Bulletin 407 Rev. T Instructions for Installation, Operation, Care and Maintenance 4 (100 mm), 6 (150 mm), 8 (200 mm) Sizes With Model E3 Trim Listed by Underwriters
More informationLift Station Design Standards and Details. Summary of Revisions
Lift Station Design Standards and Details Summary of Revisions April 2017 Updates Standard Detail SLS 19 SUBMERSIBLE LIFT STATION GROUDING PLAN & S Removed Barbed Wire from FENCE GROUNDING. TYPICAL LIFT
More informationMcNICOLL BUS GARAGE. Public Open House June 12, 2017 Mary Ward Catholic School
McNICOLL BUS GARAGE Public Open House June 12, 2017 Mary Ward Catholic School THE NEED FOR A NEW BUS GARAGE riders Increased ridership means buses Need for new buses garage And a new bus facility Garages
More information