POWER FACTOR CORRECTION
|
|
- Peter Cunningham
- 5 years ago
- Views:
Transcription
1 MODULAR UNITS A complete range of modular units, which are very simple to install inside an existing cabinet to provide automatic power factor correction systems. Manufacutred from galvanised sheet steel, with contactors specifically designed for capacitor switching, with suitably rated fuses and holders for each switching stage and utilising three phase capacitors for increased reliability. Standard Units CT TYPE: Includes busbar terminals CTX TYPE: Without busbar terminals Both CT and CTX types are equipped with PRT series capacitors. Units with Filters CT F TYPE: CTFX TYPE: Includes busbar terminals Without busbar terminals Both CT and CTX types are equipped with PRT series capacitors. CT TYPE CTF TYPE Note: Refer to Technical Data on page 13 for dimensions.
2 MODULAR UNITS Technical Data for Modular Units Code Capacitance Voltage Current Switching L D H (when ordering add EC before code) kvar) (V) (A) Stages (mm) (mm) (mm) (x kvar) CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT CTX x CT40212 CTX x CT CTX x CT CTX x CONTROL REGULATORS The EPF range of automatic power factor correction regulators are equipped with microprocessor management, steps activiation with THD I% control, temperature control and serial connectors (only for 8-12 steps versions). The unit is designed with the technology to check very distorted signals and then ensure an accurate control of plant/network electrical values such as voltage, current, power factor, internal temperature of the equipment and voltage harmonic distortion (EPF8T - EPF12T). Standard Version (6 Stage) Features: Full Auto/Manual Setting Automatic CT Polarity Check Display: PF, A, V. Alarms: Under/over correction Advanced Version (8,12 Stage) Features: As Standard Temperature Reading Harmonics Sending Max Value: Kw, V, I, Trend
3 RG1 - RG2 Series The RG1 - RG2 Series is a wall mounted automatic power factor correction system that has a correction range from 7.5 to 175kvar which is designed for small users. The RG1 - RG2 series is enclosed in a metal cabinet and equipped cooling fins, RAL 7035, contactors designed for capacitive loads, three-phase capacitors with discharge resistors guaranteeing a voltage reduction at the terminals according to a pre-set time and an electronic regulator for automatic correction. RGT Series The RGT Series is a wall mounted fixed power factor correction system that has a correction range from 20 to 125kvar which is designed for transformer. The RGT Series is enclosed in a metal cabinet equipped with cooling fins, RAL 7035, three-phase capacitors with discharge resistors guaranteeing a voltage reduction at the terminals according to a pre-set time. ERA1 - ERA2 - ERA3 Series ERA1 -ERA2 - ERA3 Series is a complete range of floor standing automatic power factor correction equipment designed for medium to high users. ERA Series is enclosed in a metal cabinet equipped with cooling fans, RAL 7035, removable modular units, electronic regulator and a fast tripping disconnection switch interlocked with the door. Line with Low Voltage Filters ERAF Series Complete range of floor standing automatic power factor correction equipment for use in industrial power networks for medium to high users with harmonic distortion. ERAF Series is enclosed in a metal cabinet equipped with cooling fins, RAL 7035, CTF-type removable modular units, electronic regulator and a fast tripping disconnection switch interlocked with the door. For further information please see the specific catalogues. These catalogues give full technical and dimension data.
4 Modular Units ECCT ECCT ECCT ECCT ECCT ECCT Modular tray ECCTX ECCTX ECCTX ECCTX ECCTX ECCTX and reactors ECCTF ECCTF ECCTF ECCTX Control Regulators ECEPF6-6 - ECEPF8T ECCTF ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT ECRGT Automatic wall mounted version Price ECRG / ECRG / ECRG ECRG / ECRG / ECRG / ECRG /10/ ECRG / Automatic wall mounted version Price ECRG / ECRG / ECRG ECRG ECRG ECRG ECRG
5 Automatic freestanding version Price ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / ECERA / Automatic freestanding version with reactors Price ECERAF / ECERAF / ECERAF / ECERAF ECERAF ECERAF ECERAF ECERAF ECERAF
Automatic COSYS PFC. Automatic power factor correction system NEW
Automatic COSYS PFC Automatic power factor correction system NEW cosys_178_a_1_x_cat cosys_178_a_1_x_cat appli_xxx_a  Function Your reactive energy consumption vary depending on the type and using conditions
More informationChapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design
Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly
More informationPower Factor Correction Capacitors in sheet steel cases
Power Factor Correction Capacitors in sheet steel cases Power Capacitors type LKN and LKSLT for fixed compensation of, for example, motors and transformers LKN LKSLT Sheet steel case With terminal block
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationTechnical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction
Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationUltravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS
AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS Contents Benefits of Power Factor Improvement... 4 ACCU-VAR Plus - AVC (50 to 600 KVAR) Standard and Optional Features... 5 240, 480, 600 Volt Equipment...
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationKENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO
BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard
More informationWelcome. Power Survey International
Welcome Company profile Established in 1948 Exclusively manufacture capacitor banks and harmonic filters Manufacturer of low and medium voltage products: Power Factor correction system Harmonic Filter
More informationAPC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction
APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction APC03 series provides the ideal power factor correction solution for industrial and commercial applications.
More informationThree Phase Capacitors KNK
Three Phase Capacitors KNK Features Connection profile Φ 90 and 116 mm 2-16 mm 2, Φ 136 mm 2-25 mm 2 *Use of flexible conductors only with ferrules Capacitors equipped with discharge resistors Rated power
More informationMedium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.
Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution
More informationHarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual
HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual TCI, LLC 7878 N. 86th Street Milwaukee, Wisconsin 53224 Phone: 414-357-4480 Fax: 414-357-4484 Helpline:
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationLOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department
LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS Capacitors department I Selecting the reactive energy compensation system 3 II Selecting the capacitor type 4 III ALPIVAR 6 IV V VI VII VIII SPECIAL RANGES 25
More informationAutomatic capacitor banks
NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Automatic
More informationPF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual
PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means,
More informationMetal-enclosed medium-voltage power factor correction system
Technical Data TD02607011E Supersedes June 2011 Metal-enclosed medium-voltage power factor correction system Contents Description Page Medium-voltage power factor correction... 1 Product description...
More informationPower Factor Correction
Power Factor Correction Power Factor Correction and Voltage Optimisation have been around since the turn of the 20 th century and although in many cases their individual benefits and attributes make them
More informationMetal-enclosed medium voltage power factor correction system
Supersedes November 2008 Contents Description Page Medium voltage power factor correction... 1 Product description... 1 Application description.... 2 Benefits.... 2 Univar XV (5 kv class).... 3 Product
More informationMODVAR Low voltage reactive power compensation modules Installation manual
MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal
More informationCLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation
CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation ReactiVar Transient Free Reactive Compensation Systems are ideal for use on sensitive networks Transient
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationFINHRM FINHRM5 FINHRMA FINHRMAC
HARMONIC FILTERS Power quality is a significant concern for manufacturing and power generation facilities. This is due to harmonic disturbance and reactive power, which is produced by unbalanced loads,
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationINTELLIGENT MEDIUM POWERBAR impb
INTELLIGENT MEDIUM POWERBAR impb INTELLIGENT MEDIUM POWERBAR impb E+I Engineering s Intelligent Medium Powerbar (impb) is a 600 Volt encased track busduct. The range is available in two bar configurations
More informationPower System Solutions (PSS)
About Power System Solutions mission The Power System Solutions Mission Statement To achieve customer satisfaction by providing innovative solutions to improve upon power quality, energy efficiency, and
More informationPricelist w.e.f. 09th September 2013 SYNTRON - COSROBOT AUTOMATIC POWER FACTOR CONTROLLER TYPE , , , ,500.
Pricelist w.e.f. 09th September 2013 AUTOMATIC POWER FACTOR CONTROLLER TYPE 1188 1 2 882 4,850.00 2 4 884 5,600.00 3 6 886 6,500.00 4 8 888 7,500.00 AUTOMATIC POWER FACTOR CONTROLLER TYPE 1143 FOR 230V
More informationAIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)
FILE NO. A90-9922 SERVICE MANUAL AIR-CONDITIONER Outdoor Unit Multi Controller 2-PIPE SUPER MULTI, HEAT PUMP MAR-M104HTM8-PE RBM-Y1034-PE (3-way) RBM-Y1044-PE (4-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationPower Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units
Power Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units TELEGROUP QUALITY From birth, Telegroup, has made the solution of problems related to energy, its core business, differentiating
More informationHV Compensation & Filtering Products
GE Grid Solutions HV Compensation & Filtering Products Providing Power Quality and Energy Efficiency High Voltage (HV) reactive power compensation and harmonic filtering solutions help customers to improve
More informationAC/DC FFE converter power module
Sheet 1 PRODUCT DESCRIPTION The converter series FFE (Fundamental Front End) consists of a three-phase IGBT bridge working at mains frequency and works as rectifier/regenerative bridge allowing the flow
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationARTECHE LOW VOLTAGE CAPACITOR BANKS. smartbat LV.
ARTECHE LOW VOLTAGE CAPACITOR BANKS. smartbat LV. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products described here. Moving together
More informationSmart Energy & Power Quality Solutions. Main catalogue 2012/2013. Power Factor Correction / Power quality
Smart Energy & Power Quality Solutions Main catalogue 2012/2013 Power Factor Correction / Power quality Power Quality Solutions Power quality and supply reliability are extremely important in the modern
More informationPRODUCT CATALOGUE 2016
PRODUCT CATALOGUE 2016 Static digital voltage stabilisers The static stabiliser is used when the correction speed represents the critical issue (for example, computers, laboratory equipment, measuring
More informationHigh Reliable Components for Power Factor Correction and Power Quality
High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Power Factor Correction Capacitors Type LKT Features that matter: Overcurrent up to 2.2 times rated
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationMaster MPS kva kva 3:1 3:3 VFI TYPE
DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready f lywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency Control
More informationORION PLUS three-phase kVA
ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through
More informationSynchronous motor control. 8/15/2007 Powerflow Technologies Inc 1
Synchronous motor control 8/15/2007 Powerflow Technologies Inc 1 PLC Lubrication units Cooling Water DCS PLC Dampers SUB BD Breaker Protection relay Field Application Kiln System Fan Hydraulic Unit Instrumentation
More informationDYNACOMP. The top-class reactive power compensator
DYNACOMP The top-class reactive power compensator Dynacomp vs Electromechanical switching of capacitors Electromechanical switching of capacitors The Dynacomp : the top-class dynamic compensator Transients
More informationProduct Groups. Standard Features
Product Groups UCW series Single-phase capacitor UCWT series Three-phase capacitor unit up to MCW series Three-phase module with single-phase units BCWT series Bank of three phase capacitors with or without
More informationtechnical catalogue tetris KW Chiller and heat pumps air/water
technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit
More informationLCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.
LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2
More informationPCOR30 Microwave Oven
PCOR30 Microwave Oven Page # Description 2 Door Assembly 3 Control Panel Assembly 4 Hardware/Wiring Harnesses/Accessories 5-8 Oven and Cabinet Parts Revised 09-20-2011 PCOR30 Microwave Door Assembly 4-35
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationPower Quality and Energy Management
Power Quality and Energy Management 1 2 Contents Power Quality...2 Power Factor Correction...4 Voltage Optimisation...8 Harmonic Filters and Reactors...12 1 Captech is Power Investigation and identification
More informationThis generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationamp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT
amp ramp Operators Manual Saftronics S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD 6QT Tel: 0484 530893 Fax: 0484 550500 Website:www.saftronics.co.uk E-Mail: sales@saftronics.co.uk
More informationS H A D E S ELECTRICAL DB MANUFATURING
CORPORATE BROCHURE S H A D E S ELECTRICAL DB MANUFATURING S H D E S ELECTRICAL DB MANUFACTURING L.L.C. www.shadesdb.com I N T R O D U C T I O N Welcome to SHADES, this portfolio has been designed to give
More informationHarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual
HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form
More informationHVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars
HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications,
More informationW SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES
W SERIES IMPULSE VOLTAGE TEST SYSTEM Impulse Voltage Test System is used to generate impulse voltages from 100 KV to 2400 KV simulating lightning strokes and switching surges with energies up to 240 KJ.
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationDynamic PFC:Thyristor Modules TSM Series
Dynamic PFC:Thyristor Modules TSM Series P o w e r Q u a l i t y S o l u t i o n s www.epcos.com/pfc The collection of PQS is a library with in-depth information on PFC applications, case studies and reference
More informationPower Systems Trainer
Electrical Power Systems PSS A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilisation Key Features Simulates generation, transmission,
More informationLoad Resistors Testing Resistors
Load Resistors Testing Resistors customized solutions optionally with control system and switchgear GINO Load and Testing Resistors Inspection, Maintenance and Protection of Power Sources Applications:
More informationCALTRAP INSTALLATION AND OPERATIONS MANUAL
INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationPower Factor Correction
Power Factor Correction Medium Voltage Automatic Capacitor Bank Save energy and reduce Carbon dioxide emission! FRANKE GMKP LTD. Http://www.frankegmkp.com 17015 Berlin,Germany Email:info@frankegmkp.com
More informationPower factor correction and harmonic filtering. MV capacitors banks and accessories
Power factor correction and harmonic filtering MV capacitors banks and accessories MV capacitors banks and accessories Introduction R8/9-3 R.8 - MV capacitors and accessories CHV-M Single-phase capacitor
More informationMV capacitors banks and accessories
Power factor correction and harmonic filtering 8 R. /9 MV capacitors banks and accessories R. 8 /9 MV capacitors banks and accessories Introduction R8/9-3 R.8 - MV capacitors and accessories CHV-M Single-phase
More informationMedium Voltage Capacitors
Type MSCE and MSCD Features that matter: Single and Three-Phase Capacitors Up to 22 kv (50 / 60 Hz) Up to 1000 kvar For indoor and outdoor installation 1 Type MSCE and MSCD Application Product Scope The
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationSynchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd
Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan presenter Nathan Schachter SLC PLC Lubrication units Cooling Water DCS SUB BD Breaker SR469 GE STAT-XTOR PLC Field Application
More informationPower Supplies. 11/2 Introduction
Siemens AG 2009 Power Supplies 11 11/2 Introduction 4AV Non-Stabilized Power Supplies Filtered for Supply of Electronic Controls 11/4 General data 11/5 4AV2, 4AV4 power supplies, filtered, single-phase
More informationTechnical News. Power Factor Correction. What technology is best for you? Specialists in electrical and automation products, systems and solutions
Issue #79 - Winter 2018 Technical News Specialists in electrical and automation products, systems and solutions Power Factor Correction What technology is best for you? Written by Samuel Hodgetts NHP nhp.com.au
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationUnrivalled in Power Factor Correction.
Unrivalled in Power Factor Correction. Static VAR Generators (SVG) What is Power Factor? Power Factor is a measure of how effectively incoming power is used in your electrical system and is defined as
More informationElectrical Power Electric power electrical electric power Electric power electric electric
Power Calculations Electrical Power Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Electric power is
More informationGUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50/80kVA Internal Transformers GUIDE SPECIFICATION
More informationHigh Reliable Components for Power Factor Correction and Power Quality
High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Contents Power Factor Correction Capacitors Page 3 Basic Harmonic Filter Reactors Page 11 Standard
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationHIB Enclosed Inverter User Guide
HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationTECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018
TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS Product Preview & Price List 2018 Price effective: November, 2018 SMART ENERGY MANAGEMENT POWER QUALITY MANAGEMENT POWER DISTRIBUTION MANAGEMENT SECURITY & ACCESS
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More information.3 Section Waste Management and Disposal.
Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationIlluminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System
Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical
More informationnext dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.
NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES
More informationAC Capacitors Safety and Application Manual
Motors Automation Energy Transmission & Distribution Coatings AC Capacitors Safety and Application Manual Safety and Application Manual Serie: AC Capacitors Language: English Document nº: 10005056250
More informationLV Capacitor CLMD03 Power Module Instruction manual
LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...
More informationABB n.v Power Quality in LV installations
ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75
More informationPower Factor Correction
Motors Automation Energy Transmission & Distribution Coatings USA3846PF 08/12 WEG www.weg.net Electric Improving Plant Life with Capacitors Reduce Utility Costs - improved Power Factor can reduce or eliminate
More informationFIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z
PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification
More informationWARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.
SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.
More information2.2.5 Connection of stand-alone option units
2.2.5 Connection of stand-alone option units INSTALLATION AND IRING The inverter accepts a variety of stand-alone option units as required. Incorrect connection will cause inverter damage or accident.
More information