Medium Voltage Capacitors

Size: px
Start display at page:

Download "Medium Voltage Capacitors"

Transcription

1 Type MSCE and MSCD Features that matter: Single and Three-Phase Capacitors Up to 22 kv (50 / 60 Hz) Up to 1000 kvar For indoor and outdoor installation 1

2 Type MSCE and MSCD Application Product Scope The capacitors are designed for power factor correction and Harmonic filtration in power network. They are allfilm dielectric and impregnated with an environmentally friendly, Non-PCB biodegradable insulating oil. In addition each capacitor is provided with an internal discharge resistor. All FRAKO capacitors comply with most national and international capacitor standards. Capacitor benefits to - Improve Factor - Reduce Line Losses - Decrease Voltage Drop Through that it helps greater Energy Efficiency. Range: Voltage Range: Frequency: Standards: Single Phase 25kvar to 1000kvar Three Phase 50kvar to 500kvar Single Phase 1000V to 22000V Three Phase 1000V to 11000V 50Hz / 60Hz IEC, ANSI / IEEE, NEMA Technical Specification Capacitor Losses Ambient Temperature Over-voltage capability 0.2 W / kvar or less with internal fuse 0.15 W / kvar or less without internal fuse -40 C / A (+40 C) / B (+45 C) / C (+50 C) / D (+55 C) U N + 10% (up to 8 hours daily) U max Over-current capability I max I N x 1.3 Painting Color Munsell No. 5Y 7/1 Reference Standard IEC U N + 15% (up to 30 minutes daily) U N + 20% (up to 5 minutes) U N + 30% (up to 1 minute) Bushing Characteristics BIL in kv Creepage Distance in mm Strike Distance in mm Total Height in mm 60 Hz Withstand Dry Test Wet Test The standard terminal size is M12, but M16 could be applied according to rated voltage. Same Bushing is used on 60 and 75kV BIL of capacitor units. Bird Cap and Parallel-groove connector with all bushings are supplied, and it is applicable to Copper or Aluminum conductor [14~100mm² 2line]. Applied bushing could be changed by special requirements. 2

3 Type MSCE Single Phase Capacitor - Insulation Level 36 kv [50/150] Capacitor without Internal Fuse 33000, V Capacitor Rated Voltage: 19050/9530, 17320/8660 V Capacitor with Internal Fuse 33000, V Capacitor Rated Voltage: 9530, 8660 V Single-Bushing Capacitor also could be provided. Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. 3

4 Type MSCE Single Phase Capacitor - Insulation Level 24 kv [50/125] Capacitor without Internal Fuse V Capacitor Rated Voltage: 13860/6930 V Capacitor with Internal Fuse V Capacitor Rated Voltage: 13860/6930 V Single-Bushing Capacitor also could be provided. Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. 4

5 Type MSCE Single Phase Capacitor - Insulation Level 17.5 kv [38/95] Capacitor without Internal Fuse V Capacitor Rated Voltage: 8660 V Capacitor with Internal Fuse 15000, V Capacitor Rated Voltage: 8660, 7970 V Single-Bushing Capacitor also could be provided. Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. 5

6 Type MSCE Single Phase Capacitor - Insulation Level 12 kv [28/75] Capacitor without Internal Fuse 12000, V Capacitor Rated Voltage: 6930, 6350 V Capacitor with Internal Fuse 12000, V Capacitor Rated Voltage: 6930, 6350 V Single-Bushing Capacitor also could be provided. Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. 6

7 Type MSCE Single Phase Capacitor - Insulation Level 7.2 kv [20/60] Capacitor without Internal Fuse 7200, 6600, 6300, 6000 V Capacitor Rated Voltage: 4160, 3800, 3640, 3460 V Capacitor with Internal Fuse 7200, 6600, 6300, 6000 V Capacitor Rated Voltage: 4160, 3800, 3640, 3460 V Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. 7

8 Type MSCD Three Phase Capacitor - Insulation Level 12 kv [28/75] Capacitor V Capacitor Rated Voltage: V Three Phase Capacitor - Insulation Level 7.2 kv [20/60] Capacitor 7200, 6600, 6300, 6000 V Capacitor Rated Voltage: 7200, 6600, 6300, 6000 V Applied bushing could be changed by special requirements [See table under Bushing Characteristics] Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. Brackets are optional. 8

9 Type MSCD Three Phase Capacitor - Insulation Level 7.2 kv [20/60] Capacitor with Unbalanced Protection 7200, 6600, 6300, 6000 V Capacitor Rated Voltage: 7200, 6600, 6300, 6000 V Applied bushing could be changed by special requirements [See table under Bushing Characteristics]. Approximate dimensions and weights are given above. Please contact to factory for exact dimensions of a particular unit before order. Brackets are optional. 9

10 Capacitor innovation, development and production since 1928 Check out other FRAKO Products AC Capacitors Dry type design 240 V to 800 V, up to 40 kvar High current capability up to 2.7 nominal capacitor current (50 Hz) Ambient temperature up to 68 C Also available with following agency approvals: Altitude up to 4,000 meters Patented terminals offer fast, antivibration and maintanance free wiring Capacitor Switching Contactors Patented design with significant damping of inrush current Long life, tested for up to 100,000 switchings High reliability and low power losses Available for use in systems with or without reactors FRAKO Kondensatoren- und Anlagenbau GmbH Tscheulinstr. 21a Teningen Germany Phone: Fax: info@frako.com Internet: 10

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Self-healing type,

More information

Power Factor Correction

Power Factor Correction Power Factor Correction It's all about saving your money! Features that matter n Overcurrent up to 2.2 times rated current n Inrush current up to 300 times rated current n Self-healing type, segmented

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Environment-friendly,

More information

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter: LKT Heavy Duty s NEW Overcurrent up to 2.7 times rated current Inrush current up to 450 times rated current Mean Life expectancy: 200,000 h. Up to 100,000 annual switching operations Features that matter:

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification

More information

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

43-SDMS-04 REV. 00 SPECIFICATIONS FOR 43-SDMS-04 REV. 00 SPECIFICATIONS FOR SHUNT CAPACITOR BANK 13.8 kv THROUGH 69 kv FOR PRIMARY DISTRIBUTION SUBSTATIONS This specification is property of SEC and subject to change or modification without

More information

Power Factor Correction Capacitors in sheet steel cases

Power Factor Correction Capacitors in sheet steel cases Power Factor Correction Capacitors in sheet steel cases Power Capacitors type LKN and LKSLT for fixed compensation of, for example, motors and transformers LKN LKSLT Sheet steel case With terminal block

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

Advancements in AC Power Capacitor Manufacturing Techniques Solve Traditional Industry Application Problems

Advancements in AC Power Capacitor Manufacturing Techniques Solve Traditional Industry Application Problems Advancements in AC Power Capacitor Manufacturing Techniques Solve Traditional Industry Application Problems Applied Power Electronics Conference, 2014 Fort Worth, TX Presented by: John Houdek, Allied Industrial

More information

High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Contents Power Factor Correction Capacitors Page 3 Basic Harmonic Filter Reactors Page 11 Standard

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

43-SDMS-01 SPECIFICATIONS FOR

43-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR MV SHUNT POWER CAPACITOR BANK UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Description Page 1.0 SCOPE 3

More information

PhiCap Capacitors for Power Factor Correction

PhiCap Capacitors for Power Factor Correction PhiCap Capacitors for Power Factor Correction Product Profile 2000 http://www.epcos.com PhiCap AC Capacitors for Power Factor Correction General The PhiCap series, is a well approved and reliable EPCOS

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Self-healing type,

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Film Capacitors Power Factor Correction Series/Type : DWJ-series Ordering code : DWJxx-xx-x(eg. DWJ0.45-15-3) Date : Jan, 2016 LIJIU JAN 2016. Reproduction, publication and dissemination of this publication,

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type : DWJ-series Ordering code : DWJxx-xx-x(eg. DWJ0.25-15-3) Date : May, 2013 WASVAR. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained

More information

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best. Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution

More information

multicond Power capacitors Data sheet: multicond

multicond Power capacitors Data sheet: multicond Power capacitors multicond Monitoring Optimizing Recording multicond are one-phase and three-phase power capacitors for reactive current compensation, developed for networks with many harmonics. Apart

More information

Check points for the connection of Capacitor&Reactor

Check points for the connection of Capacitor&Reactor Application Reactor is used in conjuction with capacitor banks in series. Its main function is to compensative or produce reactive power. According to the purpose of use, reactor helps to limit inrush

More information

POWER CAPACITORS. Cylindrical capacitor standard duty

POWER CAPACITORS. Cylindrical capacitor standard duty Construction Dielectric: Polypropylene film Non PCB, Soft Polyurethane resin Extruded round aluminium can with stud Provided with discharge resistors Overpressure disconnector Features Three phase, delta

More information

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT LKT Features that matter: Overcurrent up to 2.2 times rated current Inrush current up to 300 times rated current Self-healing type plus over-pressure disconnector Environmental friendly, dry type, CO2

More information

High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Power Factor Correction Capacitors Type LKT Features that matter: Overcurrent up to 2.2 times rated

More information

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system Premium PFC Capacitors General capacitors in cylindrical aluminum cases have been designed for power factor correction in low-voltage plant. Loads like motors and transformers consume active power as well

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

Q pole Pole Mounted Capacitor System

Q pole Pole Mounted Capacitor System Q pole Pole Mounted Capacitor System Introduction The ABB Qpole pole mount capacitor system is an economical solution for shunt reactive compensation on overhead distribution networks. The Qpole is suitable

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

LV Capacitor CLMD03 Power Module Instruction manual

LV Capacitor CLMD03 Power Module Instruction manual LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...

More information

LV Capacitor CLMD Reliability for Power Factor Correction

LV Capacitor CLMD Reliability for Power Factor Correction LV Capacitor CLMD Reliability for Power Factor Correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric of metallized

More information

Power Factor Correction

Power Factor Correction Power Factor Correction Medium Voltage Automatic Capacitor Bank Save energy and reduce Carbon dioxide emission! FRANKE GMKP LTD. Http://www.frankegmkp.com 17015 Berlin,Germany Email:info@frankegmkp.com

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

HARMONIC FILTER REACTOR

HARMONIC FILTER REACTOR 380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV

More information

Beaver Power Factor Correction Capacitors

Beaver Power Factor Correction Capacitors Beaver Power Factor Correction Capacitors Beaver Low Voltage Power Factor Correction Capacitors are designed for long life and are made with the highest quality materials. All units are assembled in Canada

More information

Power Factor Correction Equipment

Power Factor Correction Equipment Power Factor Correction Equipment Content KNK Power Capacitors for Low Voltage GENERAL 4 KNK5015 - Cylindrical Aluminium Housing 6 KNK5065 - Cylindrical Aluminium Housing (delta connection) 8 KNK1053

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Sharda Electronics & Co. An ISO 9001:2015 Certified Company Sharda Electronics & Co. An ISO 9001:2015 Certified Company Business Profile We have been witnessing to change all our life and change continues to happen all around us every moment. Change is happening

More information

HARYANA VIDYUT PRASARAN NIGAM LTD.

HARYANA VIDYUT PRASARAN NIGAM LTD. HARYANA VIDYUT PRASARAN NIGAM LTD. TECHNICAL SPECIFICATION SSD/S-03/R-1/DGM-605 TECHNICAL SPECIFICATION FOR 33 KV CAPACITOR BANKS CHIEF ENGINEER/MM HVPNL, PANCHKULA TELEPHONE & FAX: 0172-2583724 MARCH-2017-0

More information

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6 INDEX : Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3 2 Technical Perticular for Capacitor Unit 4 3 MV Surge Capacitor Unit Drawings 6 4 Technical Perticular for Surge Capacitor Unit 7 5 MV Energy

More information

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING

More information

Three Phase Capacitors KNK

Three Phase Capacitors KNK Three Phase Capacitors KNK Features Connection profile Φ 90 and 116 mm 2-16 mm 2, Φ 136 mm 2-25 mm 2 *Use of flexible conductors only with ferrules Capacitors equipped with discharge resistors Rated power

More information

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT 33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,

More information

History. SH Power Dry Capacitors. SH Power Dry Capacitors Feature. Capacity Range. Standard and Performance.

History. SH Power Dry Capacitors. SH Power Dry Capacitors Feature. Capacity Range. Standard and Performance. www.nuin.co.kr History 1968. 01 Established "KUKKWNG Electric Factory" in Seoul. 1977. 07 Incorporate the Registered Company as "KUKKWNG Electric Co., Ltd. 1979. 04 Started Manufacturing Low Power Factor

More information

MODVAR Low voltage reactive power compensation modules Installation manual

MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number) POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

In collaboration with Frako-Germany

In collaboration with Frako-Germany In collaboration with Frako-Germany Trusted Name in Power Quality Management Since 1998 It s all about saving your money! More Power by Saving Energy About us Clariant Power System Ltd is one of the leading

More information

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Product Selection & Application Guide Product Description GE's Thyristor Switched Harmonic Filter Banks (TSC), are custom designed

More information

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A. LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2

More information

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar Abel-Zhang,Power Quality Center Manager Contents Capacitor Unit Capacitor Shunt Bank Type Solution of Filter March 7, 2017 Slide 2 Contents

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers Product English Power Quality Components for reactive power compensation MADE IN GERMANY Components for reactive power compensation. Reactive power controllers Filter circuit reactors Capacitor contactors

More information

DIN EN UL 508 / CSA 3RF A A 0 2

DIN EN UL 508 / CSA 3RF A A 0 2 PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays Zero-Point Switching, heatsink integrated Main Characteristics: Zero switching LED display Various connection technologies Plug-in control terminal

More information

Individual & fixed bank capacitors

Individual & fixed bank capacitors Individual & fixed bank capacitors L O W V O L T A G E N E T W O R K Q U A L I T Y Description High reliability Well proven features of ABB dry type power factor cor rection capacitor tech nology are incorporated

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

KOREA INDONESIA COMPANY NAME SAMWHA CAPACITOR CO., LTD. ESTABLISHMENT AUGUST 1956 HEADQUARTER USD10,000,000 CAPITAL REVENUE USD150,000,000 (2009)

KOREA INDONESIA COMPANY NAME SAMWHA CAPACITOR CO., LTD. ESTABLISHMENT AUGUST 1956 HEADQUARTER USD10,000,000 CAPITAL REVENUE USD150,000,000 (2009) SAMWHA PRODUCTS Power Capacitor 1 At a Glance KOREA THAILAND INDONESIA COMPANY NAME SAMWHA CAPACITOR CO., LTD. ESTABLISHMENT AUGUST 1956 HEADQUARTER 124, BUK- RI, NAMSA- MYUN, YONGIN- SI, KYUNGGI- DO,

More information

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK 1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

HPS EnduraCoil. Cast Resin Transformer

HPS EnduraCoil. Cast Resin Transformer HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

LV Capacitors QCap-L series Capacitors for power factor correction

LV Capacitors QCap-L series Capacitors for power factor correction LV Capacitors QCap-L series Capacitors for power factor correction ABB and power quality ABB is a leader in power and automation technologies that enable utility and industry customers to improve their

More information

MV capacitors banks and accessories

MV capacitors banks and accessories Power factor correction and harmonic filtering 8 R. /9 MV capacitors banks and accessories R. 8 /9 MV capacitors banks and accessories Introduction R8/9-3 R.8 - MV capacitors and accessories CHV-M Single-phase

More information

Power Voltage Transformers for Air Insulated Substations

Power Voltage Transformers for Air Insulated Substations Power Voltage Transformers for Air Insulated Substations Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the application of a

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

Trifazni kondenzatorji KNK

Trifazni kondenzatorji KNK Trifazni kondenzatorji KNK Features Vezava profile Φ 90 and 116 mm 2-16 mm 2, Φ 136 mm 2-25 mm 2 *Use of flexible conductors only with ferrules Capacitors equipped with discharge resistors Nazivna moč

More information

CLMD Low-voltage capacitors for reliable power factor correction

CLMD Low-voltage capacitors for reliable power factor correction CLMD Low-voltage capacitors for reliable power factor correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

Visual comparison of Plain & Hazy PP Film

Visual comparison of Plain & Hazy PP Film ECOVAR High Voltage Power Capacitors are manufactured at our Sinnar Plant in India which is an ISO 9001 accredited facility & houses a computer aided design manufacturing processing and testing infrastructure

More information

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network PRODUCT BROCHURE Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet)

More information

MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY

MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY 2014 MV POWER CAPACITORS AND BANKS BIORI IPHASO TF All film dielectric MV Power Capacitors QUALITY MADE IN ITALY Index Icar: Products and solutions 1 ICAR Quality System 3 Medium and High Voltage Solutions

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: January 2018 Version: 1 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the

More information

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY PABS Air-to-SF 6 Bushings 7.5-800 kv BUSHINGS AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS 7 - ANSI STANDARDS AN ALSTOM COMPANY PABS bushings are gas-insulated types that meet IEC 7, ANSI/IEEE or

More information

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS Capacitors department I Selecting the reactive energy compensation system 3 II Selecting the capacitor type 4 III ALPIVAR 6 IV V VI VII VIII SPECIAL RANGES 25

More information

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION OF ELECTRICITY PEDE TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar Eng. Kazem Abd Al-Hamid Eng. Ali

More information

In collaboration with Frako-Germany

In collaboration with Frako-Germany In collaboration with Frako-Germany Trusted Name in Power Quality Management Since 1998 It s all about saving your money! More Power by Saving Energy Clariant Power System Ltd introduce as one of the leading

More information

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX File: PCUP-09-002_EX Outdoor Use Indoor Use The Trans-Guard EX full-range current-limiting capacitor fuse provides both low and high current fault protection in a single, compact fuse body. As a full-range

More information

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv Current transformers Outdoor operation SF 6 -gas insulated JGF (245 550) kv General description Current transformers type JGF are used in high voltage switchgear within the 245 550 kv range. They transform

More information

Bushings for High Voltage AC Applications

Bushings for High Voltage AC Applications Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure

More information

Power Factor Correction Capacitors Harmonic Filter Reactors

Power Factor Correction Capacitors Harmonic Filter Reactors CONSISTENT QUALITY SUPERIOR TECHNOLOGY ENERGY EFFICIENT Harmonic Filter Reactors Tibrewala Electronics Limited About Us As one of the most renowned manufacturers of Capacitors and MPP Film in India, Tibrewala

More information

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for a fixed, medium-voltage, padmounted, three-phase power capacitor bank

More information

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability. GE Grid Solutions OTCF Capacitor Voltage Transformers 72.5 kv to 800 kv In high and extra high voltage transmission systems, capacitor voltage transformers (CVTs) are used to provide potential outputs

More information

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for an automatic, medium-voltage, padmounted, three-phase power capacitor

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled 1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R

More information

PhaseCap HD Capacitors for Power Factor Correction

PhaseCap HD Capacitors for Power Factor Correction Series/Type: Ordering code: Date: 2005-12-14 Version: 3 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information