ACO Water Management: Civils + Infrastructure

Size: px
Start display at page:

Download "ACO Water Management: Civils + Infrastructure"

Transcription

1 ACO Water Management: Civils + Infrastructure Uniclass L223 + L735 CI/SfB (52.5) EPIC J343 ACO MultiDrain PPD ACO MultiDrain PPD channel drainage system Specification manual

2 ACO MultiDrain PPD Introduction to the ACO Group Throughout the world, the ACO brand is recognised as a leading supplier in the design, development and manufacture of surface water drainage systems. An extensive portfolio offers the market quality solutions for every application, including internal and building drainage, landscaping, sport facilities, retail, distribution centres, highways and airports as well as solutions for environmentally sensitive projects. The ACO Group has been manufacturing and selling market leading drainage systems for over 40 years. During this time the group has made extensive investment in global research and development and manufactures products world wide at 3 modern environmentallysensitive production sites. Designed with applications in mind, ACO Group surface water drainage systems are manufactured using a diverse range of materials including: Vienite, ACO s high strength recycled material Polymer concrete Steel Plastic Ductile iron The ACO group /

3 Contents Introduction to ACO MultiDrain PPD 4 ACO MultiDrain PPD features overview 6 Components of the ACO MultiDrain PPD system layout 8 ACO MultiDrain PPD product selector ACO MultiDrain MPPD ACO MultiDrain MPPD channels with galvanised edge rails 2 ACO MultiDrain MPPD accessories 2 ACO MultiDrain MPPD traditional gratings and Brickslot tops 4 ACO MultiDrain MPPD hydraulic performance tables 6 ACO MultiDrain M50PPD ACO MultiDrain M50PPD channels with galvanised edge rails 8 ACO MultiDrain M50PPD accessories 8 ACO MultiDrain M50PPD traditional gratings and Brickslot tops 20 ACO MultiDrain M50PPD hydraulic performance tables 22 ACO MultiDrain M200PPD ACO MultiDrain M200PPD channels with galvanised edge rails 24 ACO MultiDrain M200PPD accessories 24 ACO MultiDrain M200PPD traditional gratings 26 ACO MultiDrain M200PPD hydraulic performance tables 27 ACO Universal Gully 28 Designing a drainage system 29 Installation detail 30 Chemical resistance chart 33 Frequently asked questions 34 Model specification clause and declaration of conformity 35 3

4 ACO MultiDrain PPD Introduction to ACO MultiDrain PPD The new ACO MultiDrain PPD channel and grating system provides versatile and efficient linear drainage for infrastructure and hard landscaping projects. What is ACO MultiDrain PPD? ACO MultiDrain PPD m constant depth channel elements are available in 3 widths: mm, 50mm and 200mm. This gives the designer the means to select the optimum channel size and hydraulic performance required, minimising the number of outlets and keeping installation costs as low as possible. An extensive choice of grating styles, materials and load classes is available fitted with the ACO Drainlock fastening system, which provides simple and quick installation yet prevents traffic displacing the gratings. If there is a risk of unwanted grating removal or theft then security locking systems are available. Where slot drainage is preferred ACO Brickslot tops are available for the mm and 50mm wide channels, providing discreet slot drainage in either block paving or natural stone surfaces. The offset drainage slot also enables ACO Brickslot to be used right up to building façades or for threshold drainage. 4 Why choose the ACO MultiDrain PPD system? The system meets the highest standards for performance and quality, being fully compliant with and independently certified to BS EN 433:2002 for applications ranging from A 5 up to and including D 400*, ideal for pedestrians, cars, service vehicles or HGV traffic. The constant depth m recycled polypropylene channels with protective galvanised steel edge rails are extremely robust and durable yet all weigh under 5kg thanks to ACO s unique HexTechnology channel structure. ACO MultiDrain PPD has the performance to withstand the rigours of installation and provide long service life. Installation and maintenance costs are kept to a minimum with each channel packed with labour saving features, such as clip together end details for rapid channel connection and alignment, knockout panels for outlet pipe work, and the V shaped channel bore that promotes self cleansing. Guidance on preparation, installation and maintenance of this system is given in the ACO MultiDrain PPD installation manual or visit

5 Typical applications The ACO MultiDrain PPD system can provide a channel drainage solution for many applications by selecting the appropriate channel width, depth and grating type. Typical applications include: Commercial developments Residential developments Private and public parking areas Landscaping Light industrial units Pedestrian precincts Schools Sports and leisure facilities Discreet slot drainage Threshold drainage Cable ducting 5 Key features and benefits Range of sizes and depths suits many drainage designs Strong, robust channel unit Galvanised edge rail for improved installed strength % recyclable Extensive choice of gratings and accessories Easily cut to mm lengths Unique ACO Drainlock grating fixing improves hydraulic capacity CE marked and fully certified to BS EN 433:2002 Load Class D 400* Efficient surface water drainage for a wide variety of applications Channel design improves flow velocity, promotes self cleansing Lightweight design is simple and fast to install i If you need help with specification, design or installation, or just wish to learn more about this and other Surface Water Management products from ACO, contact our free, no obligation ACO Water Management Design Services Team who can provide advice and dedicated design support for your project or visit *Not suitable for carriageways of public roads or motorways

6 ACO MultiDrain PPD ACO MULTIDRAIN PPD FEATURES OVERVIEW ACO MultiDrain PPD gratings are fitted with the ACO Drainlock fastening system for quick installation Security locking option available to restrict unwanted grating removal Anti shunt feature holds grating securely in place Durable galvanised steel edge rail protects channel from traffic damage Channels clip together easily Sealant groove for simple watertight installations 6 V shaped channel bore improves speed of water flow and promotes self cleansing Environmentally friendly product manufactured from recycled polypropylene and % recyclable Constant depth channels are provided with a 90 channel connection

7 High quality channel CE marked and certified to BS EN 433:2002 Load Class D 400* (see table below) Channels available in mm, 50mm and 200mm widths, enabling efficient hydraulic drainage design A wide choice of gratings is available in various materials and designs Textured external surfaces and anchors key the product securely into concrete surround Vertical outlet for connection to sump units or pipework 0.5m cutting guide enables simple on site modification to create shorter channel lengths 7 HexTechnology : provides a rigid channel body during and after installation LOAD CLASSES A 5 Pedestrian, cycleways and domestic drives. B 25 C 250 D 400 Pedestrian precincts, light vehicles, private car parks and drives. Parking areas, service stations (cars) and slowmoving light commercial vehicles. Parking areas for all vehicle types*. *Not suitable for carriageways of public roads or motorways

8 ACO MultiDrain PPD Components of the ACO MultiDrain PPD system layout The layout diagram below illustrates the channels and accessories available within the ACO MultiDrain PPD range. Numerical product codes are provided after the product description for quick reference e.g. Closing end cap 85. ACO MultiDrain MPPD shallow constant depth components ACO MultiDrain MPPD constant depth components Closing end cap 85 Closing end cap 86 2 Channels 075 channel 44 0V channel 45 2 Channel 0.0J channel Outlet connectors Ømm connector 285 Ø60mm connector Sump unit* Foul air traps Ømm foul air trap 9 Ø60mm foul air trap i Guidance for using the ACO MultiDrain PPD parts tables The ACO MultiDrain PPD parts tables are shown on the forthcoming pages. The product information is split down by channel widths. This enables quick and simple product identification and selection. All channels within the ACO MultiDrain PPD range are constant depth units. * Sump unit connects to channel via Ø60mm outlet connector which is provided as part of the sump assembly. ** Sump unit connects to channel via Ø200mm outlet connector which is provided as part of the sump assembly

9 ACO MultiDrain M50PPD constant depth components ACO MultiDrain M200PPD constant depth components Closing end cap 93 Closing end cap 98 2 Channel 0.0J channel 5 2 Channel 0.0J channel Outlet connector Ø60mm connector Outlet connector Ø200mm connector Sump unit* Sump unit** Foul air traps Ømm foul air trap 9 Ø60mm foul air trap 92 5 Foul air trap Ø60mm foul air trap ACO Universal Gully Gully assembly and bucket 3360 Gully assembly no bucket For use on all ACO MultiDrain PPD systems.

10 ACO MultiDrain PPD ACO MultiDrain PPD product selector Making the right product selection ACO MultiDrain PPD is available in three width and depth configurations with two additional shallow channel options on the mm wide system. In order to summarise the options available, the product selector below displays key features for each of the system widths. Once product selection has been made based on the features required, the table will direct you to the appropriate page. CHANNELS WITH TRADITIONAL GRATINGS ACO MULTIDRAIN MPPD ACO MULTIDRAIN M50PPD ACO MULTIDRAIN M200PPD KEY FEATURES mm 50mm 200mm CHANNEL WIDTH CATCHMENT AREA 252m 2* 67m 2* 440m 2* SHALLOW CONSTANT DEPTH CHANNELS CONSTANT DEPTH CHANNELS MAXIMUM LOAD CLASS GRATING CHOICE BRICKSLOT TOP GO TO PAGE GO TO PAGE 7 GO TO PAGE 23 KEY CATCHMENT AREA AVAILABILITY *EXAMPLE RUN BASED ON 50m LENGTH TO OUTLET AVAILABLE NOT AVAILABLE GRATING CHOICE LOAD CLASS D 400 LIMITED SMALL WIDE PARKING AREAS FOR ALL VEHICLE TYPES. NOT SUITABLE FOR CARRIAGEWAYS OF PUBLIC ROADS OR MOTORWAYS.

11 ACO MultiDrain MPPD MPPD ACO MULTIDRAIN MPPD mm The ACO MultiDrain MPPD channels are available in shallow and constant depths and have integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channels are manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain MPPD range of gratings to suit these channels please refer to pages 4 and m 2* Channel width mm Catchment area Shallow constant depth channels Constant depth channels Load Class D 400 i To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Grating choice WIDE Brickslot top available *Example run based on 50m length to outlet

12 ACO MultiDrain PPD ACO MultiDrain MPPD Shallow constant depth channels with galvanised edge rails 44 MPPD No. 075* Length 0 42 overall MPPD No. 0* mm 0mm mm Constant depth channel with galvanised steel edge rails 40 MPPD No. 0.0J* Length 0 42 overall mm 0mm mm 50mm 25mm 75mm 5675mm 30mm 76mm MPPD m shallow depth channel 30mm 76mm MPPD m constant depth channel 2 Universal closing end caps 85 MPPD shallow channel universal closing end cap Length 38 overall MPPD universal closing end cap mm 38mm 5mm mm 38mm 50mm MPPD shallow channel universal closing end cap MPPD universal closing end cap J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ømm and Ø60mm outlet connectors. Outlet connectors supplied separately, see opposite page for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

13 ACO MultiDrain MPPD Outlet connectors 285 Ømm vertical outlet connector Length Ø overall Ø60mm vertical outlet connector Ø mm 8mm 60mm 60mm 3mm 80mm 80mm 80mm Ømm MPPD Ømm vertical outlet connector Max flow from channel 075 = 4.8 l/s 0 = 5.5 l/s 0.0 = 7. l/s Ø60mm MPPD Ø60mm vertical outlet connector Max flow from channel 075 = 6. l/s 0 = 7. l/s 0.0 = 9.2 l/s MPPD sump unit 385 Black plastic sump unit with plastic silt bucket and Ø60mm outlet connector Length 350 Ø2 overall MPPD Standard sump outlets Grating level = Ømm outlet Ø68mm = Ø60mm outlet = including channel: 075 = 287mm (6. l/s) 0 = 32mm (7. l/s) 0.0 = 362mm (9.2 l/s) = : 075 = 557mm (6. l/s) 0 = 582mm (7. l/s) 0.0 = 632mm (9.2 l/s) Ømm Ømm 5mm 3 Foul air traps 9 Ømm foul air trap Length 240 Ø overall Ø60mm foul air trap 340 Ø Grating level 240mm 340mm Ømm 400mm Ø60mm 45mm Ø60mm Ø2mm Ømm 350mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit 5 including channel: 6 including channel: 075 = 287mm (6. l/s) 075 = 32mm (6. l/s) Grating level 0 = 32mm (7. l/s) 0 = 337mm (7. l/s) 0.0 = 362mm (9.2 l/s) 0.0 = 387mm (9.2 l/s) 5 6 Roddable foul air trap LLDPE Ømm Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

14 ACO MultiDrain PPD ACO MultiDrain MPPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class A 5 applications Product code 26 Slotted galvanised steel 400DL Length 0 Width overall 23 overall 2 Slot width / hole dia Intake area mm 2 /m 3200 Anti shunt feature Weight (kg) Slotted galvanised steel 402DL Perforated galvanised steel 2666DL Perforated galvanised steel 2667DL DL / 402DL Slotted galvanised steel 2666DL / 2667DL Perforated galvanised steel Traditional gratings for Load Class C 250 applications 4 Product code 2680 Heelguard composite black 522DL Length Width overall 23 overall 2 Slot width / hole dia 8 Intake area mm 2 /m 4250 Anti shunt feature Weight (kg) Intercept ductile iron 507DL x Slotted galvanised steel 423DL Slotted galvanised steel 424DL Perforated galvanised steel 2656DL Perforated galvanised steel 2657DL Mesh galvanised steel 4DL x Mesh galvanised steel 42DL x DL Heelguard composite 507DL Intercept ductile iron 423DL / 424DL Slotted galvanised steel 2656DL / 2657DL Perforated galvanised steel 4DL / 42DL Mesh galvanised steel Indicates security locking available. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

15 ACO MultiDrain MPPD Brickslot tops and access top for Load Class C 250 applications Brickslot top galvanised steel Length 0 35 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) Brickslot top galvanised steel Brickslot access top galvanised steel mm / 2346 Brickslot top galvanised steel Slot detail Brickslot access top galvanised steel. Traditional gratings for Load Class C 250 / D 400 * applications MPPD Product code Heelguard ductile iron 23405DL Length Width overall 23 overall 2 Slot width / hole dia 8 Intake area mm 2 /m Anti shunt feature Weight (kg) Solid cover ductile iron 23406DL Slotted ductile iron 23408DL DL Heelguard ductile iron 23406DL Solid cover ductile iron 23408DL Slotted ductile iron Brickslot tops and access top for Load Class C 250 / D 400 * applications Brickslot top galvanised steel Length 0 35 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) Brickslot top galvanised steel Brickslot access top galvanised steel mm / Brickslot top galvanised steel Grating accessories Slot detail Brickslot access top galvanised steel Drainlock security locking system Length overall Drainlock security key Drainlock grating lifting tool Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

16 ACO MultiDrain PPD ACO MultiDrain MPPD hydraulic performance tables 6 Hydraulic capacities The table opposite shows the maximum capacity of the channel, assuming uniform lateral inflow to the channel. The capacity will depend on the length of channel to the outlet and on any slope along the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO Water Management Design Services Team Please contact the ACO Water Management Design Services Team on for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system An example design method is provided on page 29 to help determine your drainage requirements. This example will enable you to use the hydraulic performance tables on this page. ACO MultiDrain MPPD 075 shallow depth channel Length to Outlet (m) Length to Outlet (m) % 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) % 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) ACO MultiDrain MPPD 0 shallow depth channel Length to Outlet (m) % 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) ACO MultiDrain MPPD No 0.0J constant depth channel

17 ACO MultiDrain M50PPD ACO MULTIDRAIN M50PPD M50PPD 50mm The ACO MultiDrain M50PPD channel is available in one constant depth and has integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channel is manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain M50PPD range of gratings to suit these channels please refer to pages 20 and 2. 67m 2* Channel width 50mm Catchment area Shallow constant depth channels 7 Constant depth channels Load Class D 400 i To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Grating choice WIDE Brickslot top available *Example run based on 50m length to outlet

18 ACO MultiDrain PPD ACO MultiDrain M50PPD Constant depth channel with galvanised steel edge rails 5 M50PPD No.0.0J* Length 0 92 overall mm 0mm 50mm 2mm 70mm 22mm 37mm M50PPD m constant depth channel Universal closing end cap 93 M50PPD universal closing end cap Length 88 overall mm 88mm 2mm M50PPD universal closing end cap 8 Outlet connector 288 Ø60mm vertical outlet connector Length Ø60 overall mm 80mm 80mm 62mm Ø60mm M50PPD Ø60mm vertical outlet connector (max flow 8 l/s) J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ø60mm outlet connectors. Outlet connectors supplied separately, see table above for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

19 ACO MultiDrain M50PPD M50PPD sump unit 386 Black plastic sump unit with galvanised steel silt bucket and Ø60mm outlet connector Length 350 Ø2 overall Grating level Standard sump outlets = Ømm outlet 2 = Ø60mm outlet Ømm Ømm Ø68mm 5mm 692mm (7. l/s) 422mm (2.6 l/s) 422mm (2.6 l/s) 692mm (8.0 l/s) 2 Foul air traps 9 92 Ø60mm Ø2mm Ømm 350mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit Ømm foul air trap Ø60mm foul air trap Length Ø Ø60 overall Grating level Grating level 240mm 9 Ømm 400mm M50PPD 422mm (2.6 l/s) 340mm Ø60mm 45mm 447mm (2.6 l/s) Roddable foul air trap LLDPE Ømm Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

20 ACO MultiDrain PPD ACO MultiDrain M50PPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class C 250 applications Product code 3073 Intercept ductile iron 3073DL Length 73 overall 2 Slot width /hole dia 2 x 30 Intake area mm 2 /m 59 Anti shunt feature Weight (kg) Mesh galvanised steel 308DL x Mesh galvanised steel 309DL x DL Intercept ductile iron 308DL / 309DL Mesh galvanised steel Traditional gratings for Load Class C 250 / D 400 * applications 20 Product code 236 Heelguard ductile iron 236DL Length 73 overall 28 Slot width /hole dia 8 Intake area mm 2 /m Anti shunt feature Weight (kg) Solid cover ductile iron 2360DL Slotted ductile iron 2364DL DL Heelguard ductile iron 2360DL Solid cover ductile iron 2364DL Slotted ductile iron Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

21 ACO MultiDrain M50PPD Brickslot tops and access top for Load Class C 250 / D 400* applications 2375 Brickslot top galvanised steel 2375 Length 0 85 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) Brickslot top galvanised steel Brickslot access top galvanised steel mm 2375 / 2376 Brickslot top galvanised steel Slot detail 2377 Brickslot access top galvanised steel. Grating accessories 2365 Drainlock security locking system Length overall Invert Type 0. M50PPD 2346 Drainlock security key Drainlock grating lifting tool *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

22 ACO MultiDrain PPD ACO MultiDrain M50PPD hydraulic performance tables Notes for ACO MultiDrain M50PPD hydraulic tables Maximum capacities for each constant depth channel, assuming uniform lateral inflow to the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO MultiDrain M50PPD No 0.0J constant depth channel Length to Outlet (m) % 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) ACO Water Management Design Services Team Please contact the ACO Water Management Design Services Team on for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system 22 An example design method is provided on page 29 to help determine your drainage requirements. This example will enable you to use the hydraulic performance tables on this page.

23 ACO MultiDrain M200PPD ACO MULTIDRAIN M200PPD The ACO MultiDrain M200PPD channel is available in one constant depth and has integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channel is manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain M200PPD gratings to suit these channels please refer to pages mm Channel width 200mm 2* Catchment 440m area Shallow constant depth channels 23 M200PPD Constant depth channels Load Class D 400 i Grating choice WIDE To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Brickslot top not available *Example run based on 50m length to outlet

24 ACO MultiDrain PPD ACO MultiDrain M200PPD Constant depth channel unit with galvanised steel edge rails 58 M200PPD No.0.0J* Length overall mm 0mm 200mm 265mm 220mm 22mm 93mm M200PPD m constant depth channel Universal closing end cap 98 M200PPD universal closing end cap Length 238 overall mm 238mm 265mm 24 M200PPD universal closing end cap Outlet connector 289 Ø200mm vertical outlet connector Length Ø200 overall mm 220mm 208mm mm Ø200mm M200PPD Ø200mm vertical outlet connector (max flow 26.7 l/s) J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ø200mm outlet connectors. Outlet connectors supplied separately, see table above for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

25 ACO MultiDrain M200PPD M200PPD sump unit 387 Black plastic sump unit with galvanised steel silt bucket and Ø200mm outlet connector Length 452 Ø255 overall Standard sump outlets Grating level 2 3 = Ømm outlet = Ø60mm outlet = Ø200mm outlet Ømm Ø2mm 5mm 747mm (26.7 l/s) Ø255mm 452mm Foul air trap 92 Ø60mm roddable foul air trap Length 340 Grating level Ø60 overall mm 25 Ø60mm 45mm 477mm (3.5 l/s) 747mm (26.7 l/s) 2 3 Ø60mm Ø200mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit M200PPD 502mm (3.5 l/s) Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

26 ACO MultiDrain PPD ACO MultiDrain M200PPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class C 250 applications Product code 3473 Intercept ductile iron 3473DL Length 223 overall 35 Slot width /hole dia 30.5 x 4 Intake area (mm 2 /m) 90 Anti shunt feature Weight (kg) Mesh galvanised steel 348DL x Mesh galvanised steel 349DL x DL Intercept ductile iron 348DL / 349DL Mesh galvanised steel Traditional gratings for Load Class C 250 / D 400 * applications 26 Product code Heelguard ductile iron 2322DL Solid cover ductile iron 23220DL Length overall Slot width /hole dia 8 Intake area (mm 2 /m) Anti shunt feature Weight (kg) Slotted ductile iron 23224DL DL Heelguard ductile iron 23220DL Solid cover ductile iron 23224DL Slotted ductile iron Grating accessories Drainlock security locking system Length overall Invert Type Drainlock security key Drainlock grating lifting tool Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

27 ACO MultiDrain M200PPD hydraulic performance tables Notes for ACO MultiDrain M200PPD Hydraulic tables Maximum capacities for each constant depth channel, assuming uniform lateral inflow to the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO Water Management Design Services Team ACO MultiDrain M200PPD No 0.0J constant depth channel Length to Outlet (m) % 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Please contact the ACO Water Management Design Services Team on for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system M200PPD An example design method is provided on page 29 to help determine your drainage requirements. 27 This example will enable you to use the hydraulic performance tables on this page.

28 ACO MultiDrain PPD ACO Universal Gully ACO Universal Gully The ACO Universal Gully provides fast and simple connection between any channel size up to 200mm width in the ACO channel drainage range. It also provides an outlet to connect to traditional underground drainage. The ACO Universal Gully is a recycled plastic modular system with a ductile iron grating and frame. Instructions for installing this gully are included in the ACO MultiDrain PPD installation manual. ACO Universal Gully and accessories 3360 Gully assembly and bucket 60 Length overall Invert Type Gully assembly no bucket Gully top assembly Base unit 605 Ø375 Ø Intermediate unit Grating and frame Connector 65 Ø Bucket polyethylene Ø275 Ø mm 660mm 28 mm 870mm 35mm 440mm mm 650mm 440mm Ø60mm 4045 l/s 440mm Gully top assembly 607, Gully pot supplied by others 440mm Gully assembly 60 and 602 mm Ø360mm Ø360mm 320mm 40mm Connector 65 Ømm Note: Plain UPVC 50mm 60mm SuperSleeve adaptor supplied with 60, 602 and 605 assembly. Grating slot width 9mm. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

29 Designing a drainage system The hydraulic capacity of channels accepting lateral inflow all along their length can be calculated by the analysis of the differential equations for spatially varied flow, a procedure that requires a computer program such as the proprietary ACO Hydro software. For detailed designs using Hydro, please contact the ACO Water Management Design Services Team. The team should also be consulted for advice where the inflow is not uniformly distributed along the channel. The hydraulic performance tables within the relevant sections have been produced from the ACO Hydro software to facilitate a quick manual design method for the determination of the drainage requirements. The columns of drainage catchment area (A m 2 ) are based on a rainfall intensity of 50mm/h, but can be adapted for use at any rainfall intensity. The columns of maximum flow rate (Q l/s) and maximum lateral inflow (q l/s/m) can be used at any rainfall intensity. DESIGN EXAMPLE i = 50mm/h D = 5m L =40m For a design of ACO MultiDrain MPPD, assume the following figures: D = 5m (depth of catchment area) L = 40m (length of channel run = length of catchment) i = 50mm/h (design rainfall intensity) Ground slope = 0% Note that any other rainfall intensity may be used. Typical intensities (from BS EN 752) are 50mm/h for areas where some ponding could be tolerated for a few minutes after heavy rainfall, or 75mm/h where ponding cannot normally be tolerated. 29. Determine the area Area = L x D = 40 x 5 = 600m 2 For a quick analysis, see the tables and the columns for area on page m 2 is too large for one 40m run of ACO MultiDrain MPPD. However a 20m run can drain 302m 2, so one central outlet will work, with 20m of channel each side, each draining 300m 2. Or for a more detailed analysis, determine the total flow rate, as follows: 2. Determine total flow (Q) Q = (area x i) / 3600 = (600 x 50) / 3600 = 8.33 l/s 3. Determine lateral inflow (q) q = Q / L = 8.33 / 40 = l/s/m 4. Determine suitable channel sizes and lengths For ACO MultiDrain MPPD interpolation between the value at 20m and 30m, a maximum length of 2m could carry l/s/m. Alternatively use ACO MultiDrain M50PPD to an end outlet, where the tables show that 40m can carry 9.8 l/s and drain 704m². 5. Check Outlet capacity Ensure that the proposed outlet has sufficient hydraulic capacity by reference to the product technical pages.

30 ACO MultiDrain PPD Installation detail CHANNELS WITH TRADITIONAL GRATINGS Asphalt pavement Concrete pavement or block paving Installation within existing slab Channel to be bedded in epoxy mortar recommended 25mm minimum thickness. This may vary depending on type of mortar used. Engineering advice may be required. Y 3 Y 2 Detail A Note 5.0 Note: Movement joint to engineers detail Detail A Wearing course Detail A Pocket to be cut into existing slab where channel is to be installed see note 7.0 Y X Concrete slab X Y Block Concrete bed and haunch see note 7.0 Z Concrete bed and haunch see note 7.0 Z Slab Load Class A 5 Detail A Detail A 3mm 5mm Block Block Pavement or haunch (construction varies) Grating Channel wall 30.0 Ground conditions: The customer should ensure that the minimum dimensions shown are suitable for the existing ground conditions. Engineering advice may be required. 2.0 Block pavements: The channels must be supported laterally and therefore blocks must be restrained from movement by bedding securely. e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar). Engineering advice may be required. 3.0 Surface cracks: Alternate crack control and movement joints transversely within bed and haunch may reduce unsightly surface cracking. Engineering advice may be required. 4.0 Joint sealant: Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from Gratings must be fitted before concreting. Best practice and workmanship ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer.

31 ACO MultiDrain PPD 6 ACO MultiDrain PPD ACO UNIVERSAL GULLY A. Excavate a 50mm bed and surround, B. Concrete* surround base unit and.0 Ground conditions: blind where necessary. Form pipes if required. Position gully The customer should ensure that the concrete* bed for base unit and set intermediate unit 2 to level. minimum dimensions shown are suitable on a mortar (or similar) levelling bed. for the existing ground conditions. Make pipe connections (PVCu or Engineering advice may be necessary. SuperSleve) as appropriate. 2.0 Block pavements: 2 2 The channel must be supported laterally and therefore blocks must be restrained from movement by bedding securely, e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar from Ronacrete, tel ). Engineering advice may be required. Min 50mm (Class AC) Min 300mm (Class D) Min 50mm (Class AC) Min 300mm (Class D) Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 C. Concrete* bed for channels allowing D. Complete concrete* surround to unit 3.0 Surface cracks: levelling mortar bed if required. 2 allowing for frame levelling bed. Alternate crack control and movement Extend concrete bed around 2 (see Cut out knock outs on gully frame 3 joints traversally within bed and haunch fig. ). Install channels (see separate and cut profile of the channel from may reduce unsightly surface cracking. channel installation recommendations) inside of unit 2. Install gully and Engineering advice may be required. with taped external joints at junction haunch concrete* to the sides of of unit 2 and end of channels. channels as recommended in separate 4.0 Joint sealant: channel installation recommendations. Concrete bed & haunch minimum strength class 25 N/mm 2 Installation manual Uniclass L223 + L735 CI/SfB (52.5) Concrete bed & haunch minimum strength class 25 N/mm 2 Fig : Shutter around gully top 200mm (Class D) or 50mm (Class AC). Concrete* the supporting surround for the gully frame. EPIC J343 Concrete bed & haunch minimum strength class 25 N/mm 2 Extended concrete Class D shown. 3 Concrete bed & haunch minimum strength class 25 N/mm 2 Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from Gratings must be fitted before concreting. Best practice and workmanship. ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer. * Refer to note 7.0 on page 5 Channel base knockout details ACO MultiDrain PPD channels are supplied with a preformed knockout in the base of the channels. This detail at the male end of the channel allows vertical connection to Ømm, Ø60mm and Ø200mm UPVC pipes and sump via outlet connectors. The knockout on the base of the channel is indicated by a hammer symbol. The method of removal and pipe connection is described below. Knockout detail. METHOD: Step : Support channel around knockout detail by placing the channel on sand or soft earth for example. Tap the knockout panel from the side indicated by the hammer symbol to remove panel. Step 2: Push fit outlet connector with integral EPDM seal into recess. Connect ongoing pipework onto connector as required. 90 channel connection detail An additional feature provided on the channels* is removable side wall panels. This feature allows channel runs to be connected together to form T or L junctions for continuous water flow through the system. Where channel connections are to be made to the side wall of these units a joint profile is provided to aid alignment and fast installation. METHOD: Step : Insert the grating to support channel. Tap segments of the knockout panel as indicated to remove. Step 2: Tidy up any remaining material. Channel connection can now be made. Removable side wall panel. *This feature does not apply to shallow depth channels. These preparation steps should be read in conjunction with the Best practice and workmanship note on page 4. Creating 0.5m channels The ACO MultiDrain PPD m channels can be cut down to form 0.5m units. A cutting guide is provided on the channel body. Once cut, connection profiles are provided to enable simple and fast installation. The method of cutting the channels is described below. Cutting guide for 0.5m channel units METHOD: Step : Place saw into the cutting guide as shown. Cut channel ensuring the saw blade follows the guide provided. Step 2: Once the channel is cut tidy up edges as required. Channels can now be used as 0.5m units. 7 CHANNELS WITH BRICKSLOT GRATINGS Standard Brickslot top Access / sump top Detail B 3mm5mm Paviours directly adjacent to frame to be bedded using an epoxy mortar. See note 2.0 Detail B Sub base Sand bed Paviours directly adjacent to frame to be bedded using an epoxy mortar. See note 2.0 Detail B Sub base Sand bed Paviour Paviour Paviour Paviour Epoxy Mortar (See Note 2.0) X Y Z Concrete bed and haunch see note 7.0 Y Z X Concrete bed and haunch see note 7.0 Pavement Steel Upstand Adjacent to a structure option Adjacent to a structure option 2 Sealant Min 80mm Polymer modified mortar or epoxy resin grout ACO MultiDrain PPD channel with Brickslot top Note: varies with unit specified Concrete bed and haunch see note 7.0 ACO MultiDrain PPD channel with Brickslot top Note: varies with unit specified Concrete bed and haunch see note 7.0 i Face of structure Class C min 50mm Class D min 200mm Face of structure Class C min 50mm Class D min 200mm An electronic version of the ACO MultiDrain PPD installation detail is available to download from the ACO website. Visit Minimum dimensions of concrete surround: For Load Class A 5, the channel is to be bedded on a suitable base according to the ground conditions. For Load Classes B 25 to D 400*, a concrete bed and surround is required. Unless otherwise stated, all units in mm. Load Class Dimension A 5 B 25 C 250 D 400* x Min 50 Min 50 Min 200 y Full depth of channel (Less Y2 if necessary) Y2 (Asphalt pavement only) Max 80 Max 25 Max 25 Y3 (Asphalt pavement only) Max 5 Max 60 Max 60 z Min 50 Min 50 Min 200 Minimum concrete compressive strength 25 N/mm 2 25 N/mm 2 30 N/mm 2 *e.g. parking areas for all types of road vehicle. Not suitable for carriageway of roads or motorways. 8.0 Security locking: All the gratings are held in the channel units by the ACO Drainlock fastening system. In addition, certain gratings can be locked into place with the use of an optional security locking system. Please see grating charts for this option. See installation drawing EE0403 for further notes on the installation of this system. This information is available on request or is available for download from 3 i ACO Water Management: Civils + Infrastructure Installation notes: General notes: Preparing the channel system for installation This section provides guidance on the preparation steps that may be required for the installation of ACO MultiDrain PPD. Specific features of the channel system are shown along with instructions for use. ACO MultiDrain PPD channel drainage system Guidance on the preparation, installation and maintenance of this system is given in the ACO MultiDrain PPD Installation manual. This document is available to download from or contact marketing@aco.co.uk to request your printed copy.

32 ACO MultiDrain PPD ACO UNIVERSAL GULLY Installation notes: A. Excavate a 50mm bed and surround, blind where necessary. Form concrete* bed for base unit and set on a mortar (or similar) levelling bed. Make pipe connections (PVCu or SuperSleve) as appropriate. Min 50mm (Class AC) Min 300mm (Class D) 2 Min 50mm (Class AC) Min 300mm (Class D) Concrete bed & haunch minimum strength class 25 N/mm 2 B. Concrete* surround base unit and pipes if required. Position gully intermediate unit 2 to level. 2 Concrete bed & haunch minimum strength class 25 N/mm 2 General notes:.0 Ground conditions: The customer should ensure that the minimum dimensions shown are suitable for the existing ground conditions. Engineering advice may be necessary. 2.0 Block pavements: The channel must be supported laterally and therefore blocks must be restrained from movement by bedding securely, e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar from Ronacrete, tel ). Engineering advice may be required. 32 C. Concrete* bed for channels allowing D. Complete concrete* surround to unit levelling mortar bed if required. 2 allowing for frame levelling bed. Extend concrete bed around 2 (see Cut out knock outs on gully frame 3 fig. ). Install channels (see separate channel installation recommendations) with taped external joints at junction and cut profile of the channel from inside of unit 2. Install gully and haunch concrete* to the sides of of unit 2 and end of channels. channels as recommended in separate channel installation recommendations. Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 3 Concrete bed & haunch minimum strength class 25 N/mm Surface cracks: Alternate crack control and movement joints traversally within bed and haunch may reduce unsightly surface cracking. Engineering advice may be required. 4.0 Joint sealant: Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from Gratings must be fitted before concreting. i Fig : Shutter around gully top 200mm (Class D) or 50mm (Class AC). Concrete* the supporting surround for the gully frame. Extended concrete Class D shown. An electronic version of the ACO Universal Gully installation detail is available to download from the ACO website. Visit Best practice and workmanship. ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer. * Refer to note 7.0 on page 3

33 Chemical resistance chart ACO polypropylene has a high resistance to dilute acids and alkalis, and is unaffected by road salt, fuel and oil, and other commonly encountered chemicals. Further details of the chemical resistance can be obtained from the ACO Water Management Design Services Team or for particular chemicals, samples of the polypropylene channels can be supplied to customers for their own testing. The chemical resistance will also depend on the temperature of the effluent. The resistance of the gratings and edge rails should also be considered. This chemical resistance chart refers to chemical at ambient temperatures (20 C) and the results are for general guidance only. Important considerations for chemical environments When reviewing potential applications for ACO MultiDrain PPD in chemical environments, the following issues should be considered; Type(s) & mixture of chemical(s). Concentration percentages. Contact time with drainage system. Temperatures of chemicals flowing into the drainage system (82 C max). Flushing system employed to clear chemicals from the drainage system. Cleaning agents should be checked for compatibility with channel materials. ACO samples can be used for final determination of chemical resistance. Grating, locking mechanism, edge rail, outlet and sump unit materials should be checked for chemical resistance. Check sealant for compatibility. Chemical medium Acetic acid, glacial Acetic acid Acetic anhydride Acetone Aluminium sulfate Ammonium chloride Ammonium nitrate Ammonium phosphate Ammonium sulfate Aniline (aminobenzene) Aniline hydrochloride Aromatic hydrocarbons Aqua regia Barium chloride Beer Benzene Benzyl alcohol Benzyl chloride Bleaching liquors Borax Butanol (butyl alcohol) Butyl acetate Butyric acid Calcium carbonate Calcium chloride Calcium hydroxide Calcium nitrate Carbon disulfide Carbon tetrachloride Carbonic acid Castor oil Chlorine water Chlorobenzene Chloroform (trichloromethane) Chromic acid Citric acid Copper chloride Copper nitrate Copper sulfate Cyclohexane Diesel fuel (DERV) Dimethyl formamide Ethanol (Ethyl Alcohol) Ethanolamine Ethyl acetate Ethyl ether Ethylene glycol Fatty acids Ferrous chloride Ferrous sulfate Ferric chloride Ferric sulfate Formaldehyde Formic acid Fruit juice Fuel oil Gasoline (petrol) Glycerine Hydrazine Hydrobromic acid Resistance: % conc Polypropylene Fair 80 Fair No No No Fair Fair Fair Fair (48 C) (48 C) (48 C) No No Saturated No Poor Poor 5 No No No 95 No No 40 Fair 50 Fair 20 / / Fair Chemical medium Hydrochloric acid Hydrofluoric acid Hydrogen peroxide Lactic acid Lead acetate Magnesium chloride Magnesium sulfate Maleic acid Methyl ethyl ketone (MEK) Motor oil Nickel chloride Nickel sulfate Nitric acid Nitrobenzine Oleic acid Oxalic acid Perchlorethyline Perchloric acid Phosphoric acid Plating liquors Potassium carbonate (Potash) Potassium chloride Potassium dichromate Potassium hydroxide Potassium nitrate Potassium permanganate Potassium sulfate Pyridine Sodium acetate Sodium benzoate Sodium carbonate Sodium chlorate Sodium chloride Sodium hydroxide (caustic soda) Sodium hypochlorite Sodium nitrate Sodium peroxide Sodium silicate Sodium sulfate Sodium sulfide Sodium sulfite Sodium thiosulfate Stearic acid Sulfur dioxide Sulfuric acid Sulfuric acid Sulfuric acid at up to 48 C Tetrachloroethylene Tannic acid Tanning liquors Toluene Trichloroacetic acid Turpentine Urea Urine Water Xylene Zinc sulfate % conc 20 / (48 C) 50 / 40 No (48 C) (48 C) (48 C) (48 C) (48 C) 75 >75 (at C) Resistance: Polypropylene / Fair / No Fair No Fair No Fair No 33

34 ACO MultiDrain PPD Frequently Asked Questions 34 Q WHAT LOAD CLASS DO I REQUIRE? Answer: The answer to this question is dependent on where the drainage system will be used. There are six load classes recognised in BS EN 433:2002. For further information on load classes and applications relevant to this system, please refer to page 7. Please note that all channels within the ACO MultiDrain PPD system are certified to BS EN 433: 2002 Load Class D 400*. The system has a wide range of gratings with varying load classes which, once installed with the channel, determines the system s load class. Careful consideration should be given to the application requirement when selecting a grating. * Not suitable for carriageways of public roads or motorways Q2 DO I NEED A SUMP UNIT/UNIVERSAL GULLY? Answer: This is dependent on the requirements for sediment collection or a foul air trap. If either of these are required then a sump or gully is necessary. If not you can use any of the other outlet options available. The ACO Universal Gully (3360) has a roddable foul air trap built into the side of the unit. Note that the hydraulic capacity of end outlets and bottom outlets will be much less than the capacity of a sump or gully. Q3 ARE ACO CHANNELS SUITABLE FOR USE WITH CHEMICALS? Answer: This is entirely dependent on the chemicals being used along with their temperature and concentration. For more information, please refer to the ACO MultiDrain PPD chemical resistance chart provided on page 33. Q4 WHICH PRODUCTS ARE SUITABLE FOR USE WITH LEVEL ACCESS THRESHOLDS? Answer: Most ACO channels are suitable for level thresholds and are Part M compliant. ACO recommend systems such as ACO MultiDrain PPD, ACO MultiDrain MD or ACO ParkDrain are used for public thresholds where security of the gratings needs to be taken into account. These systems are all available with Heelguard gratings which limit the possibility of stiletto heels being caught. Q5 IS THERE A REGULATION REGARDING HEELGUARD? Answer: No. Heelguard is name created by ACO for gratings where the slot width is around 8mm. ACO MultiDrain PPD has a choice of Heelguard gratings and also a selection of wider mm slot gratings. The standard for surface water drainage BS EN 433:2002, states that the maximum slot width in most pedestrian situations is 8mm. Q6 HOW MANY OUTLETS ARE REQUIRED IN A RUN? Answer: This depends entirely on the length of channel and the catchment area expected. A design example is provided in the hydraulics guide on page 29. If a specific hydraulic calculation is required, please contact the ACO Water Management Design Services Team on Q7 DO YOU MANUFACTURE PRECURVED CHANNELS? Answer: No. ACO do not provide precurved units. However our sister division, ACO Building Drainage manufacture a stainless steel precurved product called ACO Radius channel and the ACO Sport product range includes channels to the 36.5m radius of an athletics track. For information on these products please call or refer to Q8 ARE ACO CHANNELS SELF CLEANSING? Answer: Not entirely, but the V shaped channel bore improves speed of water flow and promotes a degree of self cleansing. If there is a significant ground slope, for instance in excess of 2%, self cleansing could be achieved. We recommend any channel system is cleaned at least once a year to ensure optimum performance. Q9 ARE PRE SLOPED CHANNELS AVAILABLE WITHIN THE ACO MULTIDRAIN PPD RANGE? Answer: No, but pre sloped channels are available within the ACO MultiDrain MD range. Q HOW DO I MAKE THE ACO MULTIDRAIN PPD SYSTEM WATER TIGHT? Answer: Instructions are provide in the ACO MultiDrain PPD Installation manual. This brochure is available to download from or contact marketing@aco.co.uk to request your copy. Q ARE RECYCLED MATERIALS USED IN THE PRODUCTION OF ACO MULTIDRAIN PPD? Answer:, ACO MultiDrain PPD channels are manufactured using recycled polypropylene. All other components within the range also contain recycled materials. For more information on the recycled content, see opposite.

35 Model specification clause The surface drainage system shall be ACO MultiDrain PPD system as supplied by ACO Technologies plc; all materials and components within the scope of this system shall be obtained from this manufacturer. The system shall be CE marked and fully compliant with BS EN 433:2002, certified to Load Class (*). A declaration of conformity shall be supplied to the Supervising Officer upon request. All units shall be manufactured from recycled polypropylene with galvanised steel edge rails. The grating shall be BS EN 433: 2002 marked and tested to Load Class (*). The system shall be installed in accordance with the manufacturer s printed recommendations, and the work carried out as specified on the Supervising Officer s drawing no. ( ) and in accordance with recognised good practice. Standards of workmanship shall generally be as specified in BS EN 752 and BS 8000:Part 4:989. * insert information A 5, C 250 or D 400 as appropriate Please insert drawing number relevant to the project NBS Specifications ACO MultiDrain PPD should be specified in section Q:80. Assistance in completing this clause can be found in the ACO Drain entry in NBS Plus, or please contact the ACO Water Management Design Services Team. Note: A specification in NBS format is available to download from or Recycled content ACO Technologies aims to incorporate as much recycled material or waste material as is practicable in its manufactured products. Typically, cast iron materials contain 40% to 90% recycled iron, and steel products contain 25% to 33% recycled steel. The total recycled content of the ACO MultiDrain PPD system will vary as the proportion of different materials (in the channel, edge rails, gratings etc) varies. As an example the ACO MultiDrain PPD channel with Heelguard ductile iron gratings will contain at minimum approximately 35% by weight recycled material. The ACO MultiDrain PPD products are themselves intended for a long life with low maintenance, to reduce the need to recycle, but when eventually they are no longer needed, much of their content can be readily recycled with a very low risk of pollution to the environment. 35 Conformity The ACO MultiDrain PPD system is CE marked and fully certified to BS EN 433:2002. Test certificates and a declaration of conformity are available on request. Please contact the ACO Water Management Design Services Team on for further information. BS EN 433:2002

ACO Water Management: Urban + Landscape Civils + Infrastructure

ACO Water Management: Urban + Landscape Civils + Infrastructure ACO Water Management: Urban + Landscape Civils + Infrastructure Uniclass L223 + L735 CI/SfB (52.5) EPIC J343 ACO Channel Lighting Systems ACO Channel Lighting Systems Technical Data ACO Channel Lighting

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L2123 + L7315 CI/SfB (52.5) EPIC J3413 ACO MultiDrain MD ACO MultiDrain MD - channel drainage system Product Overview ACO MultiDrain MD System Product

More information

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) If9 Surface drainage for heavy duty traffic applications ACO RoadDrain ACO RoadDrain CHANNEL DRAINS Load Class (BS EN 1433:2002) Optimum solution ACO RoadDrain

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD Medium duty channel drainage system ACO MultiDrain MD Introduction to the ACO

More information

ACO Drain. For more information on ACO Drain visit ACO KerbDrain 280 Splay

ACO Drain. For more information on ACO Drain visit  ACO KerbDrain 280 Splay Uniclass L223 + L735 EPIC J343 ACO Drain ACO KerbDrain Splay CI/SfB (52.5) ACO KerbDrain Splay Kompact combined drainage and kerb system ACO KerbDrain Splay Product Overview Introduction to ACO KerbDrain

More information

ACO Qmax Unit size

ACO Qmax Unit size ACO Qmax 50 ACO Qmax 50 ACO Qmax 50 The ACO Qmax 50 channel is manufactured from recycled MDPE which is lightweight, chemically resistant and extremely robust. Its circular bore, ed push fit channel connections

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L2123 + L7315 CI/SfB (52.5) EPIC J3413 ACO KerbDrain ACO KerbDrain Combined kerb and drainage system Technical data ACO KerbDrain Introduction to

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Brake Vortex Vortex flow controls ACO Q-Brake Vortex Introduction to the ACO Group Throughout the world, the ACO

More information

CI/SfB (52.5) May 2003 Uniclass L L2123. ACO KerbDrain The cost effective approach to kerb drainage systems

CI/SfB (52.5) May 2003 Uniclass L L2123. ACO KerbDrain The cost effective approach to kerb drainage systems CI/SfB (52.5) May 2003 Uniclass L7315 + L2123 ACO KerbDrain The cost effective approach to kerb drainage systems ACO KerbDrain COMBINED DRAINAGE AND KERB CHANNEL SYSTEM Load Class (EN 1433:2002/DIN 19580)

More information

h2* linear fall up to 20 m, stepped fall, without fall Loading classes: A 15, B 125, C 250 to EN 1433

h2* linear fall up to 20 m, stepped fall, without fall Loading classes: A 15, B 125, C 250 to EN 1433 MEADRAIN Supreme System Z 1000 Technical Data 500 130 100 1000 0 h* h1* h* h1* 1 85 (100) 1 85 (100) 1 h1* = Total height 1 h* = Total height Material properties Channel body Polymer concrete based on

More information

LINEAR DRAINAGE. 50 years serving the construction industry

LINEAR DRAINAGE. 50 years serving the construction industry LINER DRINGE 50 years serving the construction industry Welcome Clark-Drain is renowned all over the world for the innovative drainage products it brings to the market. We have been offering intelligent

More information

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) In6 The most advanced drainage system of its kind ACO Qmax Technical Data ACO Qmax System Contents Load Classes 3 ACO Qmax 600 System Pedestrian and Car

More information

MEADRAIN. Traffic System MEAKERB. Technical Data. Material properties. Description and sizes. Channel body. Top section

MEADRAIN. Traffic System MEAKERB. Technical Data. Material properties. Description and sizes. Channel body. Top section MEADRAIN Traffic System MEAKERB Technical Data 154 125 500 125 250 125 154 500 125 125 250 125 190 100 190 185 100 25 30 130 360 320 310 500 Material properties Channel body Polymer concrete Compression

More information

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

Domestic Traditional Pits DOMESTIC TRADITONAL PITS Domestic Traditional Pits Ideal for use under downpipes, as a junction box, or at the end of a surfacewater drainage channels Designed for large household surfacewater drainage Australian Made from 100%

More information

Reinforced edge channels KE-100

Reinforced edge channels KE-100 Drainage with system Technical data sheet Reinforced edge channels KE-100 ANRIN SERVICE provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation

More information

ACO Polycrete Pty Ltd ACO A Global Company

ACO Polycrete Pty Ltd ACO A Global Company ACO Polycrete Pty Ltd ACO A Global Company Manufacturing and supplying the construction industry The ACO Group ACO was established in 1946 to manufacture mineral building products such as terrazzo concrete,

More information

ACO Modular. ACO Product catalogue. Modular Stainless Steel Channel Drainage System. Modular 20. Modular 125. Modular 200. Floor Drainage systems

ACO Modular. ACO Product catalogue. Modular Stainless Steel Channel Drainage System. Modular 20. Modular 125. Modular 200. Floor Drainage systems CO Modular Floor Drainage systems CO Product catalogue Modular Stainless Steel Channel Drainage System Modular 20 Modular 125 Modular 200 CO Modular Modular Stainless Steel Channel Drainage System System

More information

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC) LINEAR CAPTURE Perpendicular collection across the full width of a drainage surface such as a parking deck, street or sloped residential driveway. Excavation area and depth are less than for conventional

More information

kerb and gully range fast delivery on ex-stock items to any postcode nationwide

kerb and gully range fast delivery on ex-stock items to any postcode nationwide kilform 253/08/13 UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018 kerb and gully range fast delivery on ex-stock items to any postcode nationwide KERB RANGE Half Batter Pressed Kerbs Full Batter Pressed

More information

LANDSCAPING AQUA SPORT RECYFIX PLUS ROBUST, RECYCLED AND EASY TO INSTALL.

LANDSCAPING AQUA SPORT RECYFIX PLUS ROBUST, RECYCLED AND EASY TO INSTALL. CIVILS LANDSCAPING AQUA SPORT PLUS ROBUST, RECYCLED AND EASY TO INSTALL. 8 THE ECOLOGICAL INNOVATION PLUS channels consist of 100 % re cycled polyethylene (PE) and polypropylene (PP). They can be integrated

More information

Covers and Frames Ductile Iron Covers and Frames Gully Grates D Surface Boxes 270 Steel Covers and Frames

Covers and Frames Ductile Iron Covers and Frames Gully Grates D Surface Boxes 270 Steel Covers and Frames s and Frames Ductile Iron s and Frames 262 Ductile Iron s and Frames E600 263 Ductile Iron s and Frames D400 264 Ductile Iron s and Frames B125 267 GripTop D400 268 Gully Grates D400 269 Surface Boxes

More information

A monolithic drainage system designed to accept and convey large volumes of rainwater. Product Attributes

A monolithic drainage system designed to accept and convey large volumes of rainwater. Product Attributes Scan for more information RECYFIX Monotec Technical Guide SP3.5 A monolithic drainage system designed to accept and convey large volumes of rainwater 11.17 SURFACE PRODUCTS sp3.5 hauraton recyfix monotec

More information

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0) Infrastructure & Power FP M c Cann Tel: +44(0)1455 290 780 Fax: +44(0)1455 292 189 Infrastructure & Power Infrastructure & Power Power Infrastructure Cable Trough Systems FP McCann offers a specialist

More information

The Pump Matic Range

The Pump Matic Range The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality

More information

PARKING type SC. The polyester concrete drainage channel with 2mm protective edge profi le IMC SC EN

PARKING type SC. The polyester concrete drainage channel with 2mm protective edge profi le IMC SC EN type SC The polyester concrete drainage channel with 2mm protective edge profi le IMC SC 18-07 EN ARKING Due to their low weight, high strength, good chemical resistance and integrated galvanised or stainless

More information

ACO Modular Channel Introduction

ACO Modular Channel Introduction ACO Modular Channel Introduction ACO Modular Channel system overview ACO Modular 125 ACO Modular 200 ACO Slot Drain All ACO Modular Channel systems can be used in conjunction with ACO Floor Drain bodies

More information

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN TECNICA type SE The polyester concrete drainage with 4mm protective edge profi le IMC SE 5-5 EN TECNICA SE - SE5 - SE2 - SE3 EN 433 Class D4 - E6 Due to their low weight, high strength, good chemical resistance

More information

Heavy Duty Commercial Pits

Heavy Duty Commercial Pits HEVY DUTY COMMERCIL PITS HEVY DUTY PITS Heavy Duty Commercial Pits Ideal for driveways, carparks and any trafficable areas Easy to maintain Lock down security grate kits available for Series 450/600 ustralian

More information

CATALOGUE SEWAGE MANHOLES

CATALOGUE SEWAGE MANHOLES CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch

More information

SOLUTIONS WE OFFER YOU... ulmaarchitectural.com. ULMA Architectural Solutions -

SOLUTIONS WE OFFER YOU... ulmaarchitectural.com. ULMA Architectural Solutions - SOLUTIONS WE OFFER YOU... ULMA Architectural Solutions - info@ WHO WE ARE We are part of the ULMA Group, one of the largest Business Groups in northern Spain which has been on the market for more than

More information

POWER & INFRASTRUCTURE SOLUTIONS

POWER & INFRASTRUCTURE SOLUTIONS POWER & INFRA- STRUCTURE POWER & INFRASTRUCTURE SOLUTIONS v.2.2 CABLE DUCTING BT COMMS BOXES CABLE TROUGH SYSTEMS FIRE & BLAST WALLS FPMCCANN.CO.UK Magherafelt UddingSton Alnwick Lisnaskea ARMAGH Weston

More information

fit! Perfect CLARK-DRAIN CD 300SR CD 300 CLKS 422 THE NEW Polypropylene Cover and Frame! NEW Polypropylene Cover and Frame! THE UK S NUMBER ONE

fit! Perfect CLARK-DRAIN CD 300SR CD 300 CLKS 422 THE NEW Polypropylene Cover and Frame! NEW Polypropylene Cover and Frame! THE UK S NUMBER ONE CD 300SR new! CD 300 NEW Polypropylene Cover and Frame! NEW Polypropylene Cover and Frame! ISSUE 4 CLARK-DRAIN THE Perfect fit! new! CLKS 422 Slide and Snap Locking INSIDE THIS ISSUE Page Carrying Capacities

More information

STORA-DRAIN PARKING POLYESTER CONCRETE DRAINAGE CHANNEL GALVANIZED PROFILE

STORA-DRAIN PARKING POLYESTER CONCRETE DRAINAGE CHANNEL GALVANIZED PROFILE 05 WITH POLYESTER CONCRETE DRAINAGE CHANNEL GALVANIZED PROFILE 05 A15 / / POLYESTER CONCRETE DRAINAGE CHANNEL WITH GALVANIZED PROFILE Due to their low weight, high strength, good chemical resistance and

More information

Drainage and building solutions for Wildlife Conservation ACO Wildlife Systems

Drainage and building solutions for Wildlife Conservation ACO Wildlife Systems Uniclass N3 EPIC Q11 CI/SfB (52.5) ACO Wildlife Systems ACO Wildlife Systems ACO and the environment ACO is a manufacturing company at the forefront of drainage technology producing a number of products

More information

Introduction. Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry.

Introduction. Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry. Introduction Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry. All products are manufactured in accordance with the industry standard BS EN 124: 1994 which

More information

MEA RIN Plus 100 and Expert 100. Technical data sheet. Material properties. Description and sizes. Edge protection MEARIN Plus

MEA RIN Plus 100 and Expert 100. Technical data sheet. Material properties. Description and sizes. Edge protection MEARIN Plus MEA RIN Plus and Expert Technical data sheet 136 0 Plus.1RW channel Plus.1 channel Plus.0 channel 158 Ø110 184 184 Ø110 Material properties Channel body and accessories SMC (sheet moulded compound) Glassfibre

More information

Stability and Diversity

Stability and Diversity Page 18 BIRCOsir NW BIRCOsir NW Stability and Diversity Channel elements 1% internal inbuilt fall steel angle (V2A, combi-closure system not in V2A) 180 3 250 50 50 Nr. 0/0 Nr. 15 Channel no. 1 0 mm /

More information

Aim higher. Soil & Waste System

Aim higher. Soil & Waste System Aim higher Soil & Waste System Driven by durability FACT Trend towards prefabrication In most countries the labour costs are becoming an increasing part of the total installed cost of a project. To keep

More information

MUNICIPAL WATER PRODUCTS OVERVIEW

MUNICIPAL WATER PRODUCTS OVERVIEW MUNICIPAL WATER PRODUCTS OVERVIEW Oldcastle Enclosure Solutions understands what makes your projects successful the right Enclosure, for the right location, for the right application. We are dedicated

More information

ACO Tiefbau. Line drainage

ACO Tiefbau. Line drainage ACO Tiefbau Drainlock gratings Line drainage Individual in function and design ACO DRAIN Multiline drainage channels made of polymer concrete new as well as tried and tested Drainlock gratings ACO. The

More information

Complete Drainage Channels with Galvanized Slotted Grating. Product Dimension Product # lbs/ Description l x h [in] unit

Complete Drainage Channels with Galvanized Slotted Grating. Product Dimension Product # lbs/ Description l x h [in] unit MEARIN 100 Complete Clear Width: 4" interior Total Width: 5.3" Material: Fiberglass Grating: Galvanized Slotted grating cover included Fall Options: Available without fall Locking System: Top Fix Snap

More information

SpeedStopper original rubber speed bumps. BART rubber heavy duty speed bumps. SMART rubber bumps extra wide. Modular rubber speed bumps

SpeedStopper original rubber speed bumps. BART rubber heavy duty speed bumps. SMART rubber bumps extra wide. Modular rubber speed bumps SPEED BUMPS page 1 page 2 page 3 page 4 page 5 page 6 page 7 page 8 SPEED RAMPS PRODUCT GUIDE SpeedStopper original rubber speed bumps BART rubber heavy duty speed bumps Fixing kit packs SMART rubber bumps

More information

GB-250. Submittal Specifications Installation Application Specific Details

GB-250. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 68" (1,727 mm) 13½" (343 mm) 51½" (1,308 mm) 38" (965 mm) SUBMITTAL 33½" (851 mm) STANDARD: 4" plain

More information

Road + Civils AG.UK.COM

Road + Civils AG.UK.COM Road + ivils AG.UK.OM Road + ivils Road + ivils drainage products AG.UK.OM DRAINAG PRODUTS PRODUT RANG Manhole Rings oncrete access chambers Shaft / Available depth of section chamber section DN 0.25m

More information

JCB ATTACHMENTS FOR MINI AND MIDI EXCAVATORS A class-leading range of attachments suitable for mini and midi excavators.

JCB ATTACHMENTS FOR MINI AND MIDI EXCAVATORS A class-leading range of attachments suitable for mini and midi excavators. JCB ATTACHMENTS FOR MINI AND MIDI EXCAVATORS A class-leading range of attachments suitable for mini and midi excavators. #completingthesolution www.jcb.com AREAS OF APPLICATION. QUICK HITCHES. CONTENTS

More information

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars Power Distribution Enclosures Pillar shells and in-ground feeder pillars Lucy Zodion Power distribution enclosures for every market Lucy Zodion is the UK s leading provider of feeder pillars with a wide

More information

MULTIV+ SYSTEM APPLICATIONS: SYSTEM SUITABLE FOR PEDESTRIAN AND SHOPPING AREAS, AS WELL AS PARKING AREAS FOR ALL TYPES OF VEHICLES.

MULTIV+ SYSTEM APPLICATIONS: SYSTEM SUITABLE FOR PEDESTRIAN AND SHOPPING AREAS, AS WELL AS PARKING AREAS FOR ALL TYPES OF VEHICLES. MUTIV+ SYSTEM APPICATIONS: SYSTEM SUITABE FOR PEDESTRIAN AND SOPPING AREAS, AS WE AS PARKING AREAS FOR A TYPES OF VEICES. DRAINAGE EVOUTION The evolution of R&D processes and our 20+ years of experience

More information

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N DESIGN GUIDE PURLINS AND GIRTS ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS S&T029N JUL 2015 CONTENTS INTRODUCTION 2 Acknowledgements 2 Disclaimer 2 Product Technical Statement 3 Producer Statement

More information

Recessed Access Covers ACCESS COVERS & DRAINAGE SYSTEMS

Recessed Access Covers ACCESS COVERS & DRAINAGE SYSTEMS Recessed Access Covers ACCESS COVERS & DRAINAGE SYSTEMS FACTA Class Table FACTA Class A EN124 Class GLW Wheel Loads Typical Applications Gross Laden Vehicle Weight (slow moving) Wheel Loads* (slow moving)

More information

GRP Composite Trench Covers Technical Guide

GRP Composite Trench Covers Technical Guide GRP Composite Trench Covers Technical Guide #coveringtheworld Table of Contents Contents Why Choose Fibrelite? Durability / Test Reports / Accreditations / Conductive Options / Lifting Handles Corrosion

More information

ACO product catalogue. ACO Industrial Drainage

ACO product catalogue. ACO Industrial Drainage ACO product catalogue ACO Industrial Drainage ACO. The future of drainage. collect: Collect and remove clean: Pre-clean and process hold: Protect and attenuate release: Pump, discharge and reuse 2 ACO

More information

Industrial Horizontal Bearings IH and HD Series

Industrial Horizontal Bearings IH and HD Series Industrial Horizontal Bearings IH and HD Series 2 3 About Us As the inventor of the hydrodynamic bearing over 100 years ago, Michell Bearings has continued to develop its products to meet the changing

More information

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines 000535 GL0098P Beta+ Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: 028 3025 4077 IRL: 048 3025 4077 Enclosed Documents DS1151P Beta+

More information

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

TRADE PRICE LIST - 1st March Below Ground & Civils Systems TRADE PRICE LIST - 1st March 2019 Below Ground & Civils Systems Introduction to Osma 2 Introduction 2 Acceptance 3 OsmaDrain 4-13 Building Drainage System 110-160 4-13 Osma UltraRib 14-17 Foul and Surface

More information

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

TRADE PRICE LIST - 1st March Below Ground & Civils Systems TRADE PRICE LIST - 1st March 2018 Below Ground & Civils Systems Introduction to Osma 2 Introduction 2 Acceptance 3 OsmaDrain 4-13 Building Drainage System 110-160 4-13 Osma UltraRib 14-17 Foul and Surface

More information

Commercial Sized Drainage

Commercial Sized Drainage ommercial Sized Drainage Ideal for collection of high surfacewater flows in large domestic & light commercial applications Specially designed self-cleaning channel base to clear high flows of stormwater

More information

BL PIEZO ELECTRIC SENSOR

BL PIEZO ELECTRIC SENSOR BL PIEZO ELECTRIC SENSOR INSTALLATION TDC Systems Limited Weston-Super-Mare ENGLAND Tel : +44 (0)1934 644299 Fax : +44 (0)1934 644255 Email : sales@tdcsystems.co.uk Web : www.tdcsystems.co.uk Introduction

More information

Hynds Telco and Electrical Pit System

Hynds Telco and Electrical Pit System Hynds Telco and Electrical Pit System Scan for more information Technical Guide SP1.1 Hynds Concrete Access Chambers and Lids are designed specifically for the telecommunication and electrical industries.

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

Design Stress = 8 Mpa

Design Stress = 8 Mpa hdpe Pipes HdPE Pipes Muna Noor Manufacturing & Trading LLC is a pioneer in the manufacture of plastic pipe systems in Oman. Today s modern polyethylene resins are highly engineered for rigorous applications

More information

CLARK-DRAIN AT A GLANCE

CLARK-DRAIN AT A GLANCE CLARK-DRAIN AT A GLANCE 50 years serving the construction industry Welcome Clark-Drain is renowned all over the world for the innovative drainage products it brings to the market. We have been offering

More information

FASERFIX STANDARD. Solid drainage channel for easy self-installation, predominantly in private areas.

FASERFIX STANDARD. Solid drainage channel for easy self-installation, predominantly in private areas. C IVI L S L A N DS CA PI N G AQ UA S P O RT FASERFIX Solid drainage channel for easy selfinstallation, predominantly in private areas. C IVI L S L A N DS CA PI N G AQ UA S P O RT FASERFIX Solid drainage

More information

Home About Us Products & Services Search Contact Us

Home About Us Products & Services Search Contact Us 1 of 2 Home About Us Products & Services Search Contact Us Inlet Sets More related links... Standard Duty Square & Rectangular Inlet Sets Inlet Grates & Frames Trench Grating & Inlet Sets Trench Grating

More information

ATLANTIC PLASTICS is a company of. UPE Multi Diameter Wide tolerance Couplings and Flange Adaptors

ATLANTIC PLASTICS is a company of. UPE Multi Diameter Wide tolerance Couplings and Flange Adaptors ATLANTIC PLASTICS is a company of UPE Multi Diameter Wide tolerance Couplings and Flange Adaptors The UPE MultiDiameter range of wide tolerance couplings and flange adaptors can be used for almost any

More information

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

Gullies. Box - Gutters. Slot - Gutters. Grease Locks Gullies Box - Gutters Slot - Gutters Grease Locks 1 for Food Processing Specifically tailored waste water systems Box Gutters Stainless steel 1.4301. These time-tested models are available in two widths

More information

THE PROTEAN AND POC-MAST DESIGN

THE PROTEAN AND POC-MAST DESIGN THE PROTEAN AND POC-MAST DESIGN Contents 1. The changing landscape of generation for power transmission and distribution. 2. The Holford rules and recommendations for OHL routing and design. 3. The current

More information

BRIDGEMONT BMS. The new force in weighbridge design

BRIDGEMONT BMS. The new force in weighbridge design BRIDGEMONT BMS The new force in weighbridge design BridgeMont BMS The Avery Weigh-Tronix BridgeMont series is a new generation in weighbridge design. As the market leader in the UK, US and Canada, BridgeMont

More information

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries Septic tanks A septic tank from Ri-Industries offers a number of benefits: Engineer-designed and built from fine tolerance steel moulds Tanks are made from 40 MPa concrete to give additional strength and

More information

Why Choose Rexnord? 866-REXNORD/ (Within the U.S.) (Outside the U.S.)

Why Choose Rexnord? 866-REXNORD/ (Within the U.S.) (Outside the U.S.) 866-REXNORD/866-739-6673 (Within the U.S.) 44-643-366 (Outside the U.S.) www.rexnord.com Why Choose Rexnord? When it comes to providing highly engineered products that improve productivity and efficiency

More information

4.5 COMPOSITE STEEL AND CONCRETE

4.5 COMPOSITE STEEL AND CONCRETE 4.5 COMPOSITE STEEL AND CONCRETE 4.5.1 RULES OF THUMB 4.5 Composite Steel and Concrete (1/11) Typical starting point Overall concrete depth 130mm (Grade 30) Depth of profiled decking 60mm Size beam with

More information

Septic Tank. Installation Guidelines

Septic Tank. Installation Guidelines Septic Tank Installation Guidelines INSTALLATION GUIDELINES FOR WPL SEPTIC TANKS These guidelines represent Best Practice for the installation of spherical SEPTIC tanks. It must be noted, however that

More information

specified to fit your environment

specified to fit your environment specified to fit your environment An Engineering solution provider offering advanced silicone and organic rubber products, for a wide range of diverse applications. Decades of experience and expertise

More information

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1 Bulletin 8 2017 P1 Terrain FUZE HDPE pipe work systems expand and contract with changes in temperature, both ambient temperature and from the temperature of the waste discharge through the pipework. This

More information

MISSION STATEMENT THE ENVIRONMENT

MISSION STATEMENT THE ENVIRONMENT EDITION 2 MISSION STATEMENT THE ENVIRONMENT ANDERTON CONCRETE PRODUCTS LTD operates in an environmentally responsible manner. The resources and processes that we have put in place are focused on achieving

More information

ACO slot and box channels

ACO slot and box channels CO slot and box channels CO stainless steel drainage CO Product catalogue CO slot and box channels CO slot channel 20 CO box channel 125 CO box channel 200 CO gully Content General introduction page Introduction

More information

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features D00.WTR.CAT.ENG0 D-00 PN 1 Water Supply D-00-C PN 1 Combination Air Valve Description The D-00 series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The

More information

SUMMER, ALL-SEASON AND WINTER TYRES 2017/18

SUMMER, ALL-SEASON AND WINTER TYRES 2017/18 SUMMER, ALL-SEASON AND WINTER TYRES 2017/18 PASSENGER CAR AND VAN SPORTY. STRONG. SAFE! Viking. A brand of Continental. SPORTY. STRONG. SAFE! SUMMER TYRES 2017/18 Viking is a Continental brand developed

More information

Cable, Utilities and Various Network Solutions. Access Covers

Cable, Utilities and Various Network Solutions. Access Covers Cable, Utilities and Access Covers Various B2 B3 B4 B5 B7 B7 B8 Access Covers F900 Modular Access Covers 600kN 400kN C250 Pit Gas Broadband Public Lighting B125 CCTV Electrical Cable Covers B10 Ermatic

More information

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1 Bulletin 2 2017 P1 Terrain FUZE HDPE pipe work systems expand and contract with changes in temperature, both ambient temperature and from the temperature of the waste discharge through the pipework. This

More information

Flexible Couplings & Saddles

Flexible Couplings & Saddles Revised 6/01 Flexible Sewer couplings are the result of many years of experience with sewer pipe connections. Today's couplings are made of specially formulated elastomeric PVC with high tear and shear

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman

More information

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69 Concrete Drainage & Accessories CPM Concrete Pipes 62 Traditional Manholes 63-65 Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69 F P McCann Concrete Pipes / Precast

More information

Elastomeric Bearings & Industrial Products. Elastomeric Bearings & Industrial Products. EA Bearings. EA Bearings. EA Series Standard Bearings

Elastomeric Bearings & Industrial Products. Elastomeric Bearings & Industrial Products. EA Bearings. EA Bearings. EA Series Standard Bearings EA Bearings EA Bearings EA Series Standard Bearings Support and Installation Part Number These bearings are designed to support a vertical load up to 2000kN with the constant bearing temperature not exceeding

More information

Classes. Class A 15. Class B 125 CLASS C 250. Class D 400. Class E 600. Class F 900 A 15 B 125 C 250 D 400 E 600 F 900

Classes. Class A 15. Class B 125 CLASS C 250. Class D 400. Class E 600. Class F 900 A 15 B 125 C 250 D 400 E 600 F 900 Classes 0,2 MM MAX 0,5 MM MAX 0,5 MM MAX 0,2 MM MAX A15 B125 C250 D400 C250 B125 A15 A 15 Class A 15 Access covers and gratings capable of withstanding a 1.5 tonnes test load. For use in areas where only

More information

BLYTH RANGE. Unique features of the Blyth Mk 2 range. tel:

BLYTH RANGE. Unique features of the Blyth Mk 2 range.  tel: Ref: S-001-04-13 Unique features of the Blyth Mk 2 range Ideal for demanding urban environments, the Blyth is a long-standing favourite and an increasingly popular choice from Furnitubes extensive range

More information

AUTOMATIC CONTROL VALVES BY RAPHAEL

AUTOMATIC CONTROL VALVES BY RAPHAEL CONTROL VALVES AUTOMATIC CONTROL VALVES BY RAPHAEL RAF PRESSURE RAF PRESSURE offers the possibility of controlling an upstream pressure, a downstream pressure or both. RAF PRESSURE REDUCING reduces and

More information

Industries. Septic Tanks

Industries. Septic Tanks Industries Septic Tanks South Australia s leading manufacturer of pre-cast concrete products including Ri Treat waste water treatment, trades waste arrestors, septic tanks and rainwater tanks www.ri-industries.com.au

More information

SUMMER, ALL-SEASON AND WINTER TYRES 2018

SUMMER, ALL-SEASON AND WINTER TYRES 2018 SUMMER, ALL-SEASON AND WINTER TYRES 2018 PASSENGER CAR AND VAN SPORTY. STRONG. SAFE! Viking. A brand of Continental. SPORTY. STRONG. SAFE! SUMMER TYRES 2018 Viking is a brand of Continental, developed

More information

British Standard Underground Hydrant Range

British Standard Underground Hydrant Range AVK UNDERGROUND HYDRANTS British Standard Underground Hydrant Range THE AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) CFS:TEH 1 of 10 APPR:KPK:JFS:07-07-16 FHWA:APPR:07-15-16 a. Description. This

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES SUMP TANKS INSTALLATION GUIDELINES Thank you for purchasing a quality SumpTank. In order to gain the maximum benefit from your purchase, we have outlined the following instructions for the installation

More information

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO: GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 33" (83.8 cm) 10" (25.4 cm) (63.5 cm) 15" (38.1 cm) (63.5 cm) SUBMITTAL STANDARD: 3" plain end inlet/outlet

More information

Transportation Engineering II UNIT - I

Transportation Engineering II UNIT - I Transportation Engineering II UNIT - I I. Components of a Permanent Way: A. Rails: Rails are the I-section members of a track laid in two parallel lines to provide a level surface for the movement of trains.

More information

Tecstrut Channel Suspension & Framing System

Tecstrut Channel Suspension & Framing System lindab I the ventilation products specialist Tecstrut Channel Suspension & Framing System Complies with HVCA specification DW144. Manufactured from corrosion resistant materials. Channels produced in accordance

More information

Low Impact Light Rail Update

Low Impact Light Rail Update Low Impact Light Rail Update Forward plan: All contracts to be signed up by end of August 2014. All feasibility to be completed by end of 2014/14 financial year. Down selection to those projects to be

More information

MEARIN 100. Drainage Systems MEARIN

MEARIN 100. Drainage Systems MEARIN MEARIN Drainage Systems Material: Fiberglass Locking System: STANDARD lock bar system Accessories: Silt box Corner unit Trap Installation bracket MEARIN 100 WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

More information

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) July 2013 1 Material July 2013 7 Production Material Polyethylene (PE) Virgin material 100 % Recycling-contents Foam-contents

More information

An innovative solution for water and sewer installation AXIS. Guided Boring System

An innovative solution for water and sewer installation AXIS. Guided Boring System An innovative solution for water and sewer installation AXIS TM Guided Boring System A need for new installation options A growing number of water and sewer projects are required to be placed precisely

More information

sump units end caps and connectors 2018 PRICE LIST VIBRO-BASE / EVO SERIES R SERIES

sump units end caps and connectors 2018 PRICE LIST VIBRO-BASE / EVO SERIES R SERIES sump units end caps and connectors VIBRO-BASE / EVO SERIES R SERIES 2018 PRICE LIST CONCRETE SUMP UNITS FOR VIBRO-BASE SERIES AND R SERIES CONFORMING TO THE EN 1433:2008 STANDARD CONCRETE SUMP UNIT COMPONENTS

More information