1 SUMP TANKS INSTALLATION GUIDELINES
2 Thank you for purchasing a quality SumpTank. In order to gain the maximum benefit from your purchase, we have outlined the following instructions for the installation and setup of KAVERI Sump tank. It must be noted, however, that these guidelines are necessarily of a general nature. It is the responsibility of others to verify that they are appropriate for the specific ground conditions and inservice loads of each installation. Similarly, a qualified specialist (e.g. civil engineering Consultant or certified installer) must verify any information or advice given by employees or agents of KAVERI regarding the design of an installation.
3 BEFORE INSTALLING YOUR TANK Ÿ Ensure Building Regulation approval. Ÿ Ensure ground porosity is suitable. Ÿ Inspect tank for damage before installation. Ÿ Once the tank has been installed, any type of claims for damage will not be acceptable. Ÿ Check orientation and heights of inlet and outlets. Ÿ Check that the tank is suitable for its application. EXCAVATION Ÿ Excavate to a depth that will provide a minimum of 6" and a maximum of 30" of cover over the top of the tank. This will avoid collapse and over-expansion of the tank and possible leakage. Ÿ Allow 18" to 24" on all sides and all ends of the tank. Failure to comply with allowance ranges could cause tank collapse. After placing the tank the pit should be filled with backfill material as specified below. Ÿ Bed the tank in well-packed sand 6" minimum in soil terrain, 12" minimum in rock terrain. The tank should be installed level. PLUMBING INSTRUCTIONS 1. The Inlet, Outlet & Vent has to be provided in the top of the tank for easy installation. 2. Inside the tank, the inlet has to be extended with a flexible pipe which is longer than One metre in length. 3. The outlet inside the tank also should be a flexible pipe. 4. An air vent has to be provided to the tank. 5. No clamping or support should be provided in any area of the tank. The tank should be free from any kind of pressure, vibration etc. 6. Provide proper clamping & support to the plumbing work so that the tank is not unduly stressed this is to ensure long life.
4 SPECIFICATION OF BACKFILL Read these instructions carefully and the same has to be followed for longer durability. The preferred material for backfill surrounding and covering the tank is a sand/gravel mixture as described below. For KAVERI SUMP tank, native soil may be used for backfill and these tanks may be left empty while backfilling. A. The sand/gravel mixture should be a mixture of sand and gravel, 100% smaller than 1½ and about 50% smaller than ¼". B. All fill should be free of any wood, masonry debris, silt or clay. C. The Backfill should be done slowly & steadily so that complete area is filled & no scope for any deformation is left. D. Backfill with 12 layers and compact each layer. E. Compact backfill under inlet, Outlet & Vent pipes thoroughly. F. Maximum allowed backfill over the top of the tank is 30. Mould soil over the top to provide positive drainage. OTHER INSTRUCTIONS Ÿ After installation it is recommended to cover the top by a concrete (RCC) slab. Ÿ Keeping the manhole, inlet and outlet area open for easy accessible.
5 DO S Ÿ Use the correct backfill material. Ÿ Install tank at furthest practical location from habitable dwellings. Ÿ Fit the Threaded Lid Properly. Ÿ Lift the tank using adequate ropes or slings. Ÿ Use only the provisions provided for inlet & outlet and don't provide them at any other place. Ÿ Protect the tank from sharp objects which could puncture or scratch and cause leakage or damage. DON'T S Ÿ Drag, Roll & Drop while handling, to avoid damage to the tank. Ÿ The tank from any impact or contact with sharp edges. Ÿ We do not recommend extending the neck of the tank under any circumstances. Ÿ Install tank deeper than the depth. Ÿ Install the tank so that it is subjected to excess ground pressure (e.g. sloping sites) or applied loads such as may be generated by the proximity of vehicular traffic. Ÿ Fill an unsupported/uninstalled tank. Ÿ Do not install any Sump tank under the path of vehicles or heavy equipment. NOTE: KAVERI Sump tanks are made of raw material that meets FDA specifications for the storage of drinking water. KAVERI Sump tanks are advised to be used as Underground tanks only and installed as per the instructions given. Any other type of use does not carry any liability/warranty.
Septic Tank. Installation Guidelines
Septic Tank Installation Guidelines INSTALLATION GUIDELINES FOR WPL SEPTIC TANKS These guidelines represent Best Practice for the installation of spherical SEPTIC tanks. It must be noted, however that
More informationGL0098P Beta+ Septic Tanks Installation & Operation Guidelines
000535 GL0098P Beta+ Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: 028 3025 4077 IRL: 048 3025 4077 Enclosed Documents DS1151P Beta+
More informationTank Installation Instructions
July 2018 RX PLASTICS 10,000-30,000 Litre Plastic MAX Water Tanks Tank Installation Instructions Warranty Terms and Conditions Tank Lifting Instructions RX PLASTICS LTD PO Box 360 Ashburton Phone +64 3
More informationGAMMA Septic Tanks Installation & Operation Guidelines
017906 GAMMA Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: +44 283025 4077 IRL: +44 283025 4077 NOR : +47 22 021 920 Enclosed Documents
More informationThe Pump Matic Range
The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationWSB clean: Installation Manual
WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4
More informationGREASE INTERCEPTOR REQUIREMENTS
CALAVERAS COUNTY WATER DISTRICT GREASE INTERCEPTOR REQUIREMENTS HANDOUT 05 Calaveras County Water District Water and Sewer Building Service Standards GREASE INTERCEPTOR REQUIREMENTS GENERAL The following
More informationRAINWATER HARVESTING SYSTEMS
BALMORALTANKS RAINWATER HARVESTING SYSTEMS Tank installation and operating manual Contents Tank information 1 Product illustrations 2 Installation: Balmoral HydroStore 4 Installation: Balmoral RWH-ST 5
More information7. Protection System Testing
MANUAL FOR INSTALLATION AND MONITORING OF UNDERGROUND STORAGE TANKS WITH FACTORY INSTALLED ANODES 1. SCOPE Manufactured by: Granby Industries 1020 André-Liné Granby, Québec, Canada, J2J 1J9. Telephone:
More informationLifting Station Type ABS Synconta 900B
310.190.014.010 EN (01/2017) 1068-00 EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) 901B 902B Symbols and notices used in this
More informationRX Tanks No Tank is built like an RX Tank
South Island RX Tanks No Tank is built like an RX Tank RX PLASTICS LTD PO Box 360 Ashburton Phone +64 3 307 9081 Email sales@rxplastics.co.nz www.rxplastics.co.nz RX Tanks MAX Tanks 15,000, 26,000 and
More informationRX Tanks No Tank is built like an RX Tank
North Island RX Tanks No Tank is built like an RX Tank RX PLASTICS LTD PO Box 360 Ashburton Phone +64 3 307 9081 Email sales@rxplastics.co.nz www.rxplastics.co.nz RX Tanks MAX Tanks 10,000, 15,000, 25,000
More informationGB-250. Submittal Specifications Installation Application Specific Details
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 68" (1,727 mm) 13½" (343 mm) 51½" (1,308 mm) 38" (965 mm) SUBMITTAL 33½" (851 mm) STANDARD: 4" plain
More informationInstallation manual. NEMO fiberglass tanks
Installation manual NEMO fiberglass tanks We recommend that you read all installation instructions before installing or setting-up tanks or reservoirs. Contractor: Before setting-up or installing tank
More informationRAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application
RAINWATER HARVESTING INSTALLATION GUIDE RH9521-12 High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application RH9521-12 Vortex Filter Operation and Maintenance Overview The RH9521-12
More informationGB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 33" (83.8 cm) 10" (25.4 cm) (63.5 cm) 15" (38.1 cm) (63.5 cm) SUBMITTAL STANDARD: 3" plain end inlet/outlet
More informationCATALOGUE SEWAGE MANHOLES
CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch
More informationInstallation & Operation Manual
Installation & Operation Manual Thank you for purchasing our AS4795.1 Butterfly Valve. Before installing or operating, please carefully read this manual to know thoroughly how to install or operate. The
More informationUnderground Gas Polyethylene (PE) Piping
Underground Gas Polyethylene (PE) Piping Installation Guide February, 2011 Featuring the Con-Stab I.D. Seal Fittings from Continental Industries, Inc. ASSEMBLY INSTRUCTIONS: I.D. SEAL CON-STAB STEP 1 Verify
More informationUniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) If9 Surface drainage for heavy duty traffic applications ACO RoadDrain ACO RoadDrain CHANNEL DRAINS Load Class (BS EN 1433:2002) Optimum solution ACO RoadDrain
More informationInstallation Manual. AdvanTex -AX20-RT Treatment Systems. Residential Applications. An illustrated guide to installing an Orenco AdvanTex
Installation Manual AdvanTex -AX20-RT Treatment Systems Residential Applications An illustrated guide to installing an Orenco AdvanTex AX20-RT Treatment System. Rev. 1.0, 1/10 Orenco Systems, Inc. Orenco
More information2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity
2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity Rev. 1 The 2010iP Simplex station is a well-engineered system designed to provide low-pressure sewer service to individual
More informationStep 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED
Installation Guide Hydro Zones Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED In planning for the installation of a new Hydro Zone, there are many important considerations that must be evaluated
More informationCable-Tight Wire Management System
Cable-Tight Wire Management System Installation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Safety
More informationInstallation Manual. AdvanTex AX-RT Treatment Systems. Residential Applications
Installation Manual AdvanTex AX-RT Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com How To Use This Manual... Page 2 Before You Begin... Page 3 Septic Tanks Used
More informationUNLOADING & HANDLING GUIDE
UNLOADING & HANDLING GUIDE This is important information on the handling of your tank that can affect your warranty. Houston PolyTank Hopkins, MO Unloading and Handling Guide Page 2 HANDLING OF TANKS DURING
More information5. Underground Requirements
Un d e rg ro u n d Re q u ire me n ts Section 5 2016 Electric Service Requirements, 3rd Edition Section 5 Underground Requirements Directory Page 5.1 General 34 5.2 Conduit Requirements 34 5.3 Trench and
More informationThe Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11
The Sika Solution Aluminium Jointing Chamber and Security Access Cover Set Package 1200 x 600 x 700H / 900H Class D Contents: Assembly Instructions p 2-8 Roadway Installation Guidelines p 9-11 Sika Technology
More informationFIVE FOOT DIAMETER TANKS
Box 220, Highway 14 West, Asquith SK S0K 0J0 PH: (306) 329-4884 Toll Free: (866) 722-6246 FAX: (306) 329-4886 Email: sales@frpmfg.com Website: http://www.frpmfg.com FIVE FOOT DIAMETER TANKS Underground
More informationBALL TANKS Underground Installation Instructions Anchor Kit Assembly and Warranty Information
PO Box 220, Asquith SK S0K 0J0 PH: (306) 329-4884 Toll Free: (866) 722-6246 FAX: (306) 329-4886 Email: sales@frpmfg.com Website: www.frpmfg.com BALL TANKS Underground Installation Instructions Anchor Kit
More information2460 / 2472 / Series Simplex Grinder Systems
Installation Manual 5651000I 2460 / 2472 / 2484 - Series Simplex Grinder Systems Features: LSG or LSGX Series 2HP Grinder Pump 24 dia. Basin available in 60, 72, or 84 depths Guide Rail System Preassembled
More informationMODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding
More informationMOCOAT FIBREGLASS PRODUCTS LTD Avenue Edmonton, AB T6B 2N2 PH: (780) FAX: (780) BALL TANKS
MOCOAT FIBREGLASS PRODUCTS LTD. 4403-68 Avenue Edmonton, AB T6B 2N2 PH: (780) 452-4763 FAX: (780) 452-9178 Email: inquiries@mocoat.com Website: www.mocoat.ca BALL TANKS Underground Installation Instructions
More informationSUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2
SUBMERSIBLE WATER PUMP Model Nos. CSE400A Part No. 7231100 0917 iss 2 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke Submersible Pump. This highly efficient pump is designed
More informationInstallation instructions and maintenance for the Graf MINIMAX -Filter internal and external
Installation instructions and maintenance for the Graf MINIMAX -Filter internal and external MINIMAX -Filter Internal Model No.: 340060 MINIMAX -Filter External Model No.: 340061 The points described in
More informationAQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual
AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual For Single-Wall and Double-Wall Fibreglass Underground Storage Tanks This Aquator Commercial Oil Water Separator (OWS)
More informationINSTALLATION INSTRUCTIONS
R913 FRP COMPOSITE STEEL UNDERGROUND STORAGE TANKS INSTALLATION INSTRUCTIONS February 2017 1.0 EXCAVATION AND BEDDING 1.1 The bottom of the excavation shall be covered with a minimum of 12 inches (305
More informationTank Wall Installation Procedure
Tank Wall Installation Procedure Preparation for Delivery 1. If the Tank Walls are dropped on site prior to installation ensure there is a flat area the tanks can be off-loaded to. 2. Ensure Tank Walls
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump
More informationThe school consists of technical articles, intended to help pump users with common matters in pumping with submersible pumps.
Grindex Pump School Grindex Pump School The school consists of technical articles, intended to help pump users with common matters in pumping with submersible pumps. Part 1: Choosing the right pump type
More informationVALVES, FIRE HYDRANTS, AND APPURTENANCES
VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)
More informationARQUA STATION DF4 + DF7
The Arqua Station DF4 + DF7 is a complete system to provide fresh tap or filtered water to public spaces. This technical pack includes: Assembly and Installation guide Care and Maintenance For more information,
More informationCOURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson
What you will learn in this lesson IN THIS LESSON, YOU WILL LEARN... Installation steps for an AdvanTex Treatment System Important inspection points for installation inspection UNIT 4-1 Installation Steps
More informationAQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual
AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual This Aquator Commercial Oil Water Separator (OWS) Operating and Maintenance Manual gives instructions for single-wall
More informationTool 3-2 Rope pump installation check list for quality control, 3 rd Edition August 2016 Rope Pump INSTALLATION checklist for quality control A A1 Des
Rope Pump INSTALLATION checklist for quality control A A1 Site selection and preparations of the well before installation Hygiene and site selection Before the Rope pump is installed on a well, please
More informationInstallation Instructions For Water Storage and Separator Tanks
FIBREGLASS UNDERGROUND STORAGE TANKS Installation Instructions For Water Storage and Separator Tanks PUBLICATION NO. INST INS WT SEP TABLE OF CONTENTS Tank Technical Support Auckland, New Zealand (64)
More informationSUBMERSIBLE WATER PUMPS
SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety
More informationSide Cutter Kit (Left and Right - fits all 68", 72", 80" Buckets) 48" Pallet Fork
Side Cutter Kit (Left and Right - fits all 68", 72", 80" Buckets) These Bolt On Side Cutters (BOSC) greatly extend bucket service life and improve penetration power into hard packed soil or stock piled
More informationInstallation Manual. Talon Series. Portable Vehicle Scale by Fairbanks Scales, Inc. All rights reserved.
Installation Manual Talon Series Portable Vehicle Scale 2007-2012 by Fairbanks Scales, Inc. All rights reserved 51158 Revision 5 12/12 Disclaimer Every effort has been made to provide complete and accurate
More informationSASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005
SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005 This section contains Saskatchewan Amendments to the diagrams and explanations in the Appendices of the National Plumbing Code,
More informationInstallation Manual. Q Series Quadplex Grinder Systems. Contents
Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed
More informationMethod. Remote solenoids. QuickInstall Guide
Remote solenoids Where remote solenoids are specified a single supply pipe is taken from the pump, or tap supply and connected to a single entry point on the remote solenoid manifold. From each solenoid
More informationPetrol & Oil Interceptor
Petrol & Oil Interceptor VP10AG > above-ground installation. > usually associated with automotive workshops such as a garage, carwash, & etc. and also referred to as a Triple Interceptor. > this tank design
More informationGENERAL INSTALLATION MANUAL
---------------------- GENERAL INSTALLATION MANUAL For Outdoor Water Products 35DF-00081 35SH-00001 35DF-00021 Return the Manual to Owner for Future Reference Prior Plumbing Experience required INSTALLATION
More informationHynds Telco and Electrical Pit System
Hynds Telco and Electrical Pit System Scan for more information Technical Guide SP1.1 Hynds Concrete Access Chambers and Lids are designed specifically for the telecommunication and electrical industries.
More informationEffective [one year after date of adoption] the provisions of this rule shall apply to:
VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 55.1 PAVED ROADS AND PUBLIC UNPAVED ROADS (Adopted / / ) A. Applicability Effective [one year after date of adoption] the provisions of this rule shall
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or
More informationInstallation Manual. D3600- Series Duplex Grinder Systems. Contents
Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory
More informationWater Connection Repair Method and Techniques
Water Connection Repair Method and Techniques LINE LOCATES APWA Colour Codes Representatives from utility companies can field locate their lines if required. Excavation Ensure excavation is on the opposite
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL Atlanta Branch Ph: (770) 919-0456 1155 Allgood Road Suite 11 Marietta, GA 30062 LANSAS Products Houston Branch PH: (800)452-4902 FAX: (209)339-8260 Ph: (832) 831-4458 6260
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationMotorcycle ATV Braking Data Analysis. Progress Report
Motorcycle ATV Braking Data Analysis Progress Report Mark D. Osborne And Russ G. Alger Keweenaw Research Center Houghton, MI 49931 February 14 TABLE OF CONTENTS Page 1. INTRODUCTION... 1 2. MOTORCYCLE
More informationUnderground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)
Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) July 2013 1 Material July 2013 7 Production Material Polyethylene (PE) Virgin material 100 % Recycling-contents Foam-contents
More informationGRAF EcoBloc Stormwater Management System
GRAF EcoBloc Stormwater Management System Scan for more information Technical Guide D9.4 High performance system for managing rain water infiltration, stormwater attenuation and rain water harvesting.
More informationSUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514
SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE submersible pump. Before attempting to use the pump, please read this manual thoroughly
More informationElite Skimmer Installation Manual. Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM
Elite Skimmer Installation Manual Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM A C G B F E D H I A B C D Biological Waterfall Box Filters harmful waste and toxins from water, keeping
More informationA Assembly Instructions Trampoline Piccolo Art with Special Installation Frame
A Assembly Instructions Trampoline Piccolo Art. 20.02.116 with Special Installation Frame Operator: Location: T:\PLAY\Play Installation Instructions\Installation Instructions 2012-2013\20_02_116-01-en-000.doc
More informationFact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage
Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage N E W M E X I C O FARM A SYST Farmstead Assessment System Fact Sheet #4 Reducing the Risk of Groundwater
More informationInstallation and maintenance instructions for the GRAF Universal External and internal Filter 3
Installation and maintenance instructions for the GRAF Universal External and internal Filter 3 Universal Filter 3 for external green areas Order- No.: 340020 Universal Filter 3 external for areas traversed
More informationInstallation Manual. AdvanTex AX20 Treatment Systems. Residential Applications
Installation Manual AdvanTex AX20 Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com Orenco Installation Manual: AX20 Treatment Systems How To Use This Manual... Page
More information2a. Excavating and Lifting
Construction Methods 110401542 2a. Excavating and Lifting Dr. Khaled Hyari Department of Civil Engineering Hashemite University Introduction Excavator: A power-driven digging machine Three Major types
More informationFILL-ON-SITE FOR REMOTE LOCATION PROJECTS
ECOBAG Geotextile Pipeline Weight (GPW) ECOBAG GPW is an easy-to-install, high-strength, free-standing pipeline set on weight that provides predictable performance in a variety of installation environments.
More informationInstallation Manual and Operating Guidelines
Installation Manual and Operating Guidelines For Single-Wall Fiberglass Underground Wastewater Tanks Owner should retain this manual for reference to operating guidelines. This Wastewater Installation
More informationThis publication is copyrighted and intended for the sole use of General Industries - 07/07/2016
AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures
More informationSeptic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks
Septic Tanks Gravity treatment Separation Sludge sinks Scum floats Storage Septic Tanks, Holding Tanks & Pump Tanks Bacteria SCUM breakdown CLEAR ZONE Chemical SLUDGE WW Strength= Organic Load Effluent
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationUTILITY CROSSING DETAIL
6" OF CSBC COMPACTED TO A FIRM AND UNYIELDING CONDITION. NOTE: - SILT FENCE SHALL CONFORM TO 8-01.3(9)A - SILT FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE. - POST SPACING MAY BE INCREASED
More informationA Assembly Instructions Space Capsule, Art-No
A Assembly Instructions Space Capsule, Art-No. 20.01.020 T:\PLAY\Play Installation Instructions\Installation Instructions 2012-2013\20_01_020-01-en-003.doc - 1 - Revision history Revision 0 2004-06-22
More informationINSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents
INSTALLATION GUIDE Model #GB2 35/50 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB2....................................... 3
More informationA Assembly Instructions Trampoline 2012 Art
A Assembly Instructions Trampoline 2012 Art. 20.02.108 Operator: Location: M:\Spogg\Englisch\20_02_108-01-en-001.doc\20-02-108-eng-01-001.doc - 1 - Revision history Revision 0 2012-03-21 Revision 1 2012-08-02
More informationTitan Series Portable Vehicle Scale
FAIRBANKS s c a l e FAIRBANKS s c a l e Installation Manual Titan Series Portable Vehicle Scale 00 by Fairbanks Scales Inc. All rights reserved 0 Issue # 0/0 Amendment Record Titan Series Portable Vehicle
More informationEPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) In6 The most advanced drainage system of its kind ACO Qmax Technical Data ACO Qmax System Contents Load Classes 3 ACO Qmax 600 System Pedestrian and Car
More informationUPP Polyethylene Dispenser Sump
UPP Polyethylene Dispenser Sump For Standard and Ribbed sump models DS2111, 4111, 3017, 4417, 3617 and 3915 Installation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608
More informationCHAPTER 140 DRIVEWAYS
CHAPTER 140 DRIVEWAYS 140.01 Purpose 140.10 Driveway Location 140.02 Definitions 140.11 Driveway Maintenance 140.03 Driveway Construction 140.12 Failure To Maintain 140.04 Driveway Surfaces 140.13 Permit
More informationSouth Cambridgeshire District Council
APPENDIX A South Cambridgeshire District Council Planning Design Guide for the Storage of Solid Waste in New Developments 1 Introduction The purpose of this Guide is to ensure that all new developments,
More informationSentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions
WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the
More informationIndustries. Septic Tanks
Industries Septic Tanks South Australia s leading manufacturer of pre-cast concrete products including Ri Treat waste water treatment, trades waste arrestors, septic tanks and rainwater tanks www.ri-industries.com.au
More informationTYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System
1.01 Typical Installation Scope TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System Section 1- General Furnish labor, equipment, tools and material to install the PPB-300 Steel Piers as
More informationMELBOURNE: BRISBANE: Ph : Fax : Ph : Fax :
www.normeng.com.au BRISBANE: Ph : 07 3376 3177 Fax : 07 3376 3201 sales@normeng.com.au www.normeng.com.au 21 Spine Street Sumner Park Queensland 4074 MELBOURNE: Ph : 03 9775 1965 Fax : 03 9770 8054 victoria@normeng.com.au
More informationPackage Pump Stations
Package Pump Stations FES & FET Final Effluent Models RSS & RST Sewage Models Environmental Wastewater Solutions www.wpl.co.uk 2 Page Contents ITEMS SUPPLIED... 3 OPTIONAL EXTRAS... 3 PRE-INSTALLATION
More informationConcrete Delivery Requirements
BORAL CONCRETE Build something great Customer Notification Concrete Delivery Requirements MARCH 2017 CONCRETE DELIVERY REQUIREMENTS - TRAFFIC MANAGEMENT, ENVIRONMENTAL At Boral we regard the safety and
More informationThe information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.
Dear Customer, Thank you for choosing a Zorzini S.p.A. product. Zorzini manway doors and manhole covers 1 are designed and manufactured according to the highest standards in regards safety, functionality
More informationUNDERGROUND CONDUIT SYSTEMS for Primary and Secondary Conductors (Rev. 7)
April 2018 UNDERGROUND CONDUIT SYSTEMS for Primary and Secondary Conductors (Rev. 7) Engineering & Asset Management Policy No. 242 Rocky Mountain Power Utah Wyoming Idaho This policy and related documents
More informationSOLID WASTE AND RECYCLING ENCLOSURE STANDARDS
SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS Kitsap County Public Works July 2019 If you have any questions regarding the Standards or have recommendations for improvement, please contact: Sarah Olson
More informationGREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District
Last Updated on October 27, 2011 Grease interceptors are required to separate out Fats, Oils and Greases (FOGs) and solids normally found in food preparation waste from the rest of the wastewater being
More informationFire Hydrant Testing, Maintenance and Repair
Fire Hydrant Testing, Maintenance and Repair What is a Fire Hydrant? A fire hydrant is used to access water directly from the local main supply, equipped with a fire hose connection for use in the event
More informationTITLE: Drainage, Better Drainage, and More Drainage PRESENTER: DARRELL D. CANTRELL CANTRELL RAIL SERVICES, INC VICE PRESIDENT ENGINEERING
TITLE: Drainage, Better Drainage, and More Drainage PRESENTER: DARRELL D. CANTRELL CANTRELL RAIL SERVICES, INC VICE PRESIDENT ENGINEERING AREMA CONFERENCE- SEPTEMBER 23, 2009 INTRODUCTION Most of the heavy
More informationPatton Hill Road (Four Inch Main), Project No
Patton Hill Road (Four Inch Main), Project No. 2016100 MP-5.01 MOBILIZATION (3% MAX) 1 LS MP-5.02.8(d) 8" DIP (CLASS 350) ALL DEPTHS 600 LF MP-5.02.6(p) 6" PVC ALL DEPTHS, INCLUDING BEDDING 10 LF MP-5.02.4(p)
More informationA Assembly instructions Mini Rope End Swinger Art. Nr
A Assembly instructions Mini Rope End Swinger Art. Nr. 4585-45 Operator: Location: Attention! The distance between the center of the poles is 3.00 x 1.00m. In case of an eventual add-on of any other rope-parcours