OT LE 600/900/1200 GAS

Size: px
Start display at page:

Download "OT LE 600/900/1200 GAS"

Transcription

1 OXYTHERM LE Burners Configured Item Number: OT LE for configured item number OT LE ASSEMBLY NUMBER PAGES SERIES FUEL Choice of burner series Choice of fuel Series Series Series G Gas O Oil for configured item number OT LE 600/900/1200 GAS BURNER MAX CAPACITY MMBTU/HR FUEL BLOCK MATERIAL PILOT FUEL NET HEAT VALUE (BTU/CF) NOZZLE VELOCITY (FPS) Maximum capacity in MMBtu/hr (varies by burner size) Choice of fuel Choice of block material Choice of pilot Heat value per cubic foot 1.0 Maximum capacity for Series Maximum capacity for Series Maximum capacity for Series 1200 N O P A Z N O 1000 Enter value Natural gas Other gas (see Engrg) Propane gas Alumina/zirconia/silica Zirconia No pilot chosen Oxy-fuel pilot chosen Required velocity 400 Enter value 32M

2 for configured item number OT LE 600 GAS NZL ORIFICE SIZE Choice of nozzle orifice size for Series X = X = X = X = X = X = X = X = X = X = X = X = X =.377 for configured item number OT LE 900 GAS NZL ORIFICE SIZE Choice of nozzle orifice size for Series X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = M i

3 for configured item number OT LE 1200 GAS NZL ORIFICE SIZE Choice of nozzle orifice size for Series X = X = X = X = X = X = 1.00 for configured item number OT LE 600/900/1200 OIL BURNER SIZE FUEL BLOCK MATERIAL PILOT FUEL HEATING VALUE (BTU/GAL) Replacement parts Choice of burner size Type of oil Choice of block material Choice of pilot /907 Series [1] Series Series Series /1230 Series (DEFAULT for 1200 Series) [1] Series [1] 2 #2 fuel oil 6 Preheated #6 fuel oil A Alumina/zirconia/silica Z Zirconia Heat value per gallon Enter value [1] For 600 Series, 07 is the only choice. For 1200 Series, 30 and 40 are the only choices N O U No pilot chosen Oxy pilot without UV location Oxy pilot with UV location OXYTHERM LE burner type Series 600 Series 900 Series 1200 Fuel service Gas Oil Gas Oil Gas Oil Block & frame (no pilot) AZS Zirconia Block & frame (with pilot AZS provision) Zirconia Body gasket Nozzle body insert Housing hex nuts (qty. 12) Krytox grease (2 oz.) Oxy pilot Oxy pilot with UV provision i 3 32M

4 GAS INSERT ASSEMBLY O-Rings [C] Gas Insert Body O-Ring [D] Gas Nozzle [B] Insert nut OXYTHERM LE gas burner model Series 600 Series 900 Series 1200 A Gas insert assembly (qty. 1) 600 OT LE REPL [1] 900 OT LE REPL [1] 1200 OT LE REPL [1] --- Nozzle body insert (qty. 1) B Gas nozzle (qty. 1) 600 OT LE REPL [1] [2] 900 OT LE REPL [1] [2] 1200 OT LE REPL [1] [2] C O-ring Viton (qty. 2) [2] [2] [2] D O-ring Viton (qty. 1) [2] [2] [2] [1] Maxon original sales order number required [2] Gas nozzle and o-rings included on gas insert assembly 32M i

5 OIL INSERT SUB-ASSEMBLY Check Valve [S] O-Ring [L] Oil Body O-Rings [M] O-Ring [N] Oil Tube Assembly [J] Oil Inlet Fitting [R] Oil Inlet Retainer [Q] O-Rings [O] Insert Nut Oil Insert Body [T] Nozzle Orifice Retainer [P] Nozzle Orifice [K] OXYTHERM LE oil burner model Oil insert (inlet body) sub-assembly Nozzle body insert Insert nut J Oil tube assembly K Oil cap (nozzle orifice) L O-ring Viton [1] (qty. 1) M O-ring Viton [1] (qty. 2) (qty. 2) N O-ring Viton [1] (qty. 1) O O-ring Viton [1] [2] (qty. 2) (qty. 1) P Orifice retainer Q Oil inlet retainer R Oil inlet fitting S Check valve T Oil insert body [1] O-rings included in oil insert sub-assembly [2] O-rings included in oil tube sub-assembly i 5 32M

6 Assembly numbers for OXYTHERM LE EX burners Gas OXYTHERM LE EX burners Description Assembly number Series 600 OXYTHERM LE EX gas burners with AZS block Series 900 OXYTHERM LE EX gas burners with AZS block Oil OXYTHERM LE EX burners Description Assembly number Series 607 OXYTHERM LE EX oil burners with AZS block Series 907 OXYTHERM LE EX oil burners with AZS block Series 910 OXYTHERM LE EX oil burners with AZS block Series 915 OXYTHERM LE EX oil burners with AZS block Series 920 OXYTHERM LE EX oil burners with AZS block Series 930 OXYTHERM LE EX oil burners with AZS block Replacement parts for OXYTHERM LE EX burners OXYTHERM LE EX burner series Series 600 Series 900 Fuel service Gas Oil Gas Oil Block & frame Orifice plate Body gasket Housing hex nuts (qty. of 12 required) Krytox grease (2 oz.) OXYTHERM LE EX gas burner model Series 600 Series 900 Gas insert assembly [1] Gas nozzle [1] Gas nozzle extension O-ring Viton [2] (qty. 2) (qty. 2) O-ring Viton [2] (qty. 2) (qty. 2) [1] Maxon original sales order number required [2] O-rings included on gas insert sub-assembly 32M i

7 OXYTHERM LE EX oil burner model Oil insert (inlet body) sub-assembly Oil tube assembly Oil cap (nozzle orifice) O-ring Viton [1] (qty. 2) (qty. 2) O-ring Viton [1] (qty. 2) (qty. 2) O-ring Viton [1] [2] (qty. 2) O-ring Viton [1] [2] (qty. 1) Orifice retainer Oil inlet retainer Oil inlet fitting Check valve Oil insert body Oil nozzle extension [1] O-rings included in oil insert sub-assembly [2] O-rings included in oil tube sub-assembly i 7 32M

8 For More Information The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, visit ThermalSolutions.honeywell.com or contact your Honeywell Sales Engineer. Honeywell MAXON branded products 201 E 18th Street Muncie, IN USA Honeywell Process Solutions Honeywell Thermal Solutions (HTS) 1250 West Sam Houston Parkway South Houston, TX ThermalSolutions.honeywell U.S. Registered Trademark 2017 Honeywell International Inc. 32M M.S. Rev Printed in United States

UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M

UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M-02007-01 TABLE OF CONTENTS Product Description... 3 Features and Benefits... 3 Applications... 3 Modes of Operation... 3 Burner Selection

More information

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS TECHNICAL CATALOG PRODUCT DESCRIPTION The KINEMAX burner is a nozzle-mixing, medium velocity burner. It provides a stream of hot combustion gases that promote

More information

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text) Series 67 TUBE-O-FLAME Burners Page 2200-A/P-1 For these products, please order per the following product numbers: (configured products are those with alphanumeric text) Size Packaged Burner 6-08 608 TOF

More information

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110 NOTES: Burner Capacity Information, BBC 111/211 NATURAL GAS, AMBIENT COMBUSTION AIR OPERATION, LOW PRESSURE ATOMIZATION Capacity (at 1% Excess Air) Gas Inlet Pressure Flame Length (at 1% Excess Air) Flame

More information

Capacities and Operating Data

Capacities and Operating Data CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

KINEMAX. Medium velocity gas or oil burners

KINEMAX. Medium velocity gas or oil burners KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate

More information

North American 4485 Tempest SE

North American 4485 Tempest SE Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable

More information

Data /1/07 Eclipse RatioAir Burners Model RA0040

Data /1/07 Eclipse RatioAir Burners Model RA0040 Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

TriOx Triple Air Staged Ultra Low NOx Burner

TriOx Triple Air Staged Ultra Low NOx Burner Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent

More information

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics

More information

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7 Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7 Parts List Bulletin PO01018 Issue/Rev 0.1 (7/13) S1, S3, S5 S6, S7 Item Description Qty. K12-S1 K12-S5 K12-S7 Page 2 SS01018 Issue/Rev.

More information

REPLACEMENT PARTS LIST. M1 Series

REPLACEMENT PARTS LIST. M1 Series REPLACEMENT PARTS LIST M Series Model MG(*) Item Description MGH MG(B,C,D) 056 070 077 090 056 070 077 090 Louvered Door (White) 9007 9007 9007 9007 9007 9007 9007 9007 Coil Door (White) 9009 9009 9009

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER CAPABILITIES Short, compact, clear and bushy flame Suitable for rich gases and most oils 10% to 300% excess air through burner with rich gaseous fuels and light oils 10% to 100% excess air through burner

More information

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750 Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000 Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.

More information

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation

More information

Emergency Generators & Fire Pump

Emergency Generators & Fire Pump Emergency Generators & Fire Pump Facility ID No.: 3301500025 Telephone No.: 773-6881 Table 1 Emission Factors lbs/1000 gallons Fuel/Sulfur Emission Factor Source Size Diesel 0.4% S AP-42, Chaper 3.3-1,

More information

Low emissions, high performance natural gas burners

Low emissions, high performance natural gas burners -.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

27" GAS DRYER MODELS: WGD94HEAW2 (White) WGD94HEAC2 (Chrome Shadow) 06/25/ Whirlpool Corporation Part No. W Rev.

27 GAS DRYER MODELS: WGD94HEAW2 (White) WGD94HEAC2 (Chrome Shadow) 06/25/ Whirlpool Corporation Part No. W Rev. 27" GAS DRYER MODELS: WGD94HEAW2 (White) WGD94HEAC2 (Chrome Shadow) 06/25/2013 2013 Whirlpool Corporation Part W10623349 Rev. A TOP AND CONSOLE PARTS 06/25/2013 2 Part W10623349 Rev. A TOP AND CONSOLE

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS GL, GS, & GT-SERIES FULLY JACKETED GAS STEAM KETTLES ML-52633 ML-52634 ML-52635 ML-52637 ML-52638 ML-52639 ML-52640 ML-52660 GS25E GS30E GL40E GL80E GT100E GT125E GT150E GS60E

More information

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction BBG Gas Beta Burner BBG-1 Edition 02-08 BBG shown with pilot ignition and converging tile options. Designed for low pressure air operation Rugged heavy gauge steel construction Alloy or refractory tile

More information

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS LOW EMIION, HIGH PERFORMANCE GA BURNER TECHNICAL CATALOG Fuel and air pressures for the burner are balanced (always equal). This unique design provides simple operation and adjustment throughout the operational

More information

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES. Models (Series B) BW9AAN BW9AAN BW9AAN000100

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES. Models (Series B) BW9AAN BW9AAN BW9AAN000100 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES Models (Series B) BW9AAN000050 BW9AAN000075 BW9AAN000100 CAC/BDP 710 West Morris St. Indianapolis, IN. 4621 P/N#

More information

UB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB90-100

UB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB90-100 UB90-100 Series 2 Models UB90-50 UB90-75 UB90-100 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model

More information

1200 SERIES FTR HOT AIR BAFFLE BURNER

1200 SERIES FTR HOT AIR BAFFLE BURNER CAPABILITIES High release rates with moderate air pressure Good turn down with flame characteristics and direction maintained Stable flames tailored to the job applications can be from highly oxidizing

More information

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS LOW EMIION, HIGH PERFORMANCE GA BURNER TECHNICAL CATALOG Fuel and air pressures for the burner are balanced (always equal). This unique design provides simple operation and adjustment throughout the operational

More information

PARTS MANUAL FOR HEAVY DUTY GAS BROILERS

PARTS MANUAL FOR HEAVY DUTY GAS BROILERS PARTS MANUAL FOR HEAVY DUTY GAS BROILERS CERAMIC MODELS Model HCB00 HCB HMCB HCB1 HCB SUNGLOW MODELS Model IR1 IR IR MODEL GHCBO0 SHOWN FORM 0907 (10-9) VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY

More information

Residential & Light Duty Commercial Gas Atmospheric Vent High Input Models

Residential & Light Duty Commercial Gas Atmospheric Vent High Input Models REPLACEMENT PARTS LIST Residential & Light Duty Commercial Gas Atmospheric Vent High Input Models Includes Hydrojet Total Performance System Effective: May, 2015 ECO 7950 NOTE: BOTH MODEL AND SERIAL NUMBERS

More information

Q90-50/75/100 Series 2 Q Series 3

Q90-50/75/100 Series 2 Q Series 3 Models Q90-50 Q90-75 Q90-100 Q90-50/75/100 Series 2 Q90-100 Series GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your

More information

Design and Application Details

Design and Application Details LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog

More information

MDG28PRCWW0 : 01 - COVER SHEET [1/7]

MDG28PRCWW0 : 01 - COVER SHEET [1/7] MDG28PRCWW0 : 01 - COVER SHEET [1/7] Page 1 of 14 MDG28PRCWW0 : 01 - COVER SHEET [1/7] Ref # Part Number Qty. Description Page 2 of 14 MDG28PRCWW0 : 02 - TOP AND CONSOLE PARTS [2/7] Page 3 of 14 MDG28PRCWW0

More information

CASH VALVES TYPE G-60 HIGH CAPACITY PRESSURE REGULATOR

CASH VALVES TYPE G-60 HIGH CAPACITY PRESSURE REGULATOR The Type G-60 is a high capacity all purpose regulator designed to operate within close operating limits. Application Type G-60 regulators are designed for use with steam, water, air, oil, gases, chemicals

More information

BBC Multi-fuel Combination Beta Burner

BBC Multi-fuel Combination Beta Burner BBC Multi-fuel Combination Beta Burner BBC-1 Edition 11-08 Designed for low pressure air operation Rugged heavy gauge steel construction Converging tile provides higher velocity flames for higher convective

More information

Data 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)

More information

Assembly Numbers Style A, B & C LINOFLAME Burners

Assembly Numbers Style A, B & C LINOFLAME Burners Premix-type Line Burners Page 00-A/P-1 Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with cast iron ignition rails L INOFLAME Burner Section Description straight section (Code) S tyle

More information

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List Issue/Rev. 0.0 (1/14) Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List Bulletin PO01023 *For meters which began shipping in 1993 to current. For meters shipped prior to

More information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information Connected Industrial Elster RABO Highly Accurate Rotary Gas Meter Applications Honeywell Elster has combined tried and tested product features of their RPM and IRM rotary meter product lines with new developments

More information

Meter, PD Series, K12-S1, S3, S5, S6 and S7

Meter, PD Series, K12-S1, S3, S5, S6 and S7 PARTS LIST Meter, PD Series, K12-S1, S3, S5, S6 and S7 Bulletin PO01018 Issue/Rev. 0.4 (3/18) S1, S3, S5 S6, S7 Item Description Qty. K12-S1 K12-S5 K12-S7 2 Bulletin PO01018 Issue/Rev. 0.4 (3/18) Item

More information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter PRODUCT FEATURES. Applications. Brief information. Operating Principle

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter PRODUCT FEATURES. Applications. Brief information. Operating Principle Connected Industrial Elster RABO Highly Accurate Rotary Gas Meter Applications Honeywell Elster has combined tried and tested product features of their RPM and IRM rotary meter product lines with new developments

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8487A FLUID END FOR OILWELL A-1100-PT / A-850-PT PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M. LENGTH 4 4 ½ 5 5

More information

68 Universal RAI-G PD Blower Visit us online:

68 Universal RAI-G PD Blower Visit us online: Authorized Howden Roots Distributor, Warranty, Service & Repair Facility 68 Universal RAI-G PD Blower Visit us online: www.fraserwoods.ca Call 1-780-962-1827 for technical, application and sales support.

More information

North American 4575 HiRAM

North American 4575 HiRAM Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace

More information

EXPLODED VIEW & PARTS LIST

EXPLODED VIEW & PARTS LIST SECTION 8 EXPLODED VIEW & PARTS LIST ALUMINUM, A300-*AA-****-*** 10 20 30 352 40 322 40 OPTIONAL 311 342 360 323 381 312 321 61 62 70 385 341 383 80 90 100 110 120 130 140 150 160 353 170 355 372 384 330

More information

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1 Gas Limiting Orifice Valve Features Precision machined valve flow piston Rugged cast iron body Replaceable cartridge assembly for LVG 55-5 Straight through valve design; right angle valve option Pressure

More information

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

Pilot Operated 2-Way Gas Valves

Pilot Operated 2-Way Gas Valves Pilot Operated 2-Way Gas Valves Model 2180ED - ductile iron Model 2180ES - cast steel Overview AMOT Model 2180 valves will shut off the fuel gas and vent the manifold when used on an internal combustion

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8488-1A FLUID END FOR OILWELL A-1700-PT/A-1400-PT MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P.

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8422A FLUID END FOR EMSCO F-1000 PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M. LENGTH 4 4 1/2 5 5 ¼ 5 ½ 5 ¾ 6 6

More information

M SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical

More information

0.05 0.10 0.08 0.10 0.08 0.10 1000 2000 3000 368 735 1103 1177 1471 2206 1766 2206 3310 400 0 1200 1281 1601 2401 1922 2400 3602 433 865 1298 1385 1731 2595 2078 2596 3894 465 930 1395 1489 1860 2790 2234

More information

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual SF-500 September 10, 2018 SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-48-NG/PG-ND gas pilot

More information

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com Page 2 Moisture + MP-GS/GD DESCRIPTION PAGE Deluxe Control Panel 4 Standard

More information

Q90-50/75/100 Series 4

Q90-50/75/100 Series 4 Q90-50/75/100 Series 4 Models Q90-50 Q90-75 Q90-100 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest supplier.

More information

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION SF-200 OCTOBER 10, 2016 SureFire II TM Pilot Forced Draught Gas Pilot type SP-32-xx-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-xx-FD gas pilot

More information

Pilot Capacities/Specifications

Pilot Capacities/Specifications s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will

More information

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,

More information

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F.  Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

UB90-50/75/100 Series 4

UB90-50/75/100 Series 4 Models UB90-50 UB90-75 UB90-100 UB90-50/75/100 Series 4 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest

More information

Includes Hydrojet Total Performance System. Effective: APRIL 24, 2009 ECO 7421

Includes Hydrojet Total Performance System. Effective: APRIL 24, 2009 ECO 7421 RESIDENTIAL AND LIGHT DUTY COMMERCIAL GAS REPLACEMENT PARTS LIST High Performance Energy Saver (GX) Non-Defender Energy Saver M(I,1,2)(XR)(65,75,100) Gallon Light Duty Energy Saver Includes Hydrojet Total

More information

CGi Series 2 Section Assembly

CGi Series 2 Section Assembly CGi Series 2 Section Assembly 8 0 2 9 9 Current Service Parts CGi Series 2 Section Assembly Part Description Mfr. Mfr. s Part -0-80 End section, left hand, cast #2 Weil-McLain 2-0-82 End section, right

More information

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN

More information

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor OPERATIONS MANUAL The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor Safe, reliable ignition and flame failure protection combined with a proven, completely self-powered

More information

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8482-25A FLUID END FOR NATIONAL 14-P-220 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M.

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8477A FLUID END FOR GARDNER DENVER PZ-11/PZ-10 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P.

More information

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual SF-200 APRIL 10, 2018 Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-NG/PG-FD gas

More information

RESIDENTIAL GAS REPLACEMENT PARTS LIST

RESIDENTIAL GAS REPLACEMENT PARTS LIST RESIDENTIAL GAS REPLACEMENT PARTS LIST Combi2 Models CDW2 Series Includes Hydrojet Total Performance System Effective: April, 2014 ECO 7928 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Power Direct Vent PDV T Model

Power Direct Vent PDV T Model REPLACEMENT PARTS LIST Power Direct Vent PDV T Model Includes Hydrojet Sediment Reduction System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT

More information

OPN DESCRIPTION QTY B-160 See next page for drawing of B-160 Blower -46-

OPN DESCRIPTION QTY B-160 See next page for drawing of B-160 Blower -46- -45- Models B-1501 B-160 OPN DESCRIPTION QTY A 002016 3/8" Jam Nut 8 B 010008 Support Rod Bracket 2 C 002017 3/8" Hex Lock Nut 2 D 100475 Lid Support Rod 2 E 010009 Lid Lift Bushings 4 F 010005 Drive-In

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8476-25A FLUID END FOR NATIONAL 12-P-160 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M.

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8482-A FLUID END FOR NATIONAL 14-P-220 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M.

More information

Replacement Parts List

Replacement Parts List 100275093_2000534000_Rev H Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Noble Boiler & Combi NKB 080-150

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST SOUTHWEST 8407-7A FLUID END FOR IDECO T-1600 / T-1300 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M.

More information

HOT WATER PRESSURE WASHER BREAKDOWN

HOT WATER PRESSURE WASHER BREAKDOWN HOUR METER TACH / HOUR ON OFF THERMOSTAT BURNER OFF 29 9 20 28 25 4 23 24 3 2 34 33 0 5 8 9 7 6 6 ITEM PART NUMBER DESCRIPTION QTY. 85.600.220 Frame 2 N/A Engine, 3 HP, 389cc (GX390 2QNR) 2 85.578.50 Engine,

More information

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,

More information

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod UNIT 1 From Serial Number: 30200001 Untill Serial Number: 31200284 1 ILLUSTRATED PARTS BREAKDOWN Edizione 2010 Rev. A 2 11 10 9 7 3 12 14 30 8 6 5 4 13 15 17 16 18 19 20 28 21 22 27 29 25 24 23 26 Cod.

More information

Burner Selection Criteria

Burner Selection Criteria UNI-RAD Radiant Tube Burners Page 4803 Burner Selection Criteria Combustion Air View Port/Optic Flame Sensor Mount Gas Inlet 3"- 4" Burner Selection The UNI-RAD Burner can be used with various radiant

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

PARTS LIST. U Series Infra-Red Salamander Broiler. models. Parts & Service.

PARTS LIST. U Series Infra-Red Salamander Broiler. models. Parts & Service. U Series Infra-Red Salamander Broiler models UIR36C UIR48 UIR36 UIR60 PARTS LIST Parts & Service T (USA & Canada): 1 800 47 6668 F (USA & Canada): 1 800 361 7745 www.garland-group.com Garland Commercial

More information

PGM Prepiped Gas Manifold

PGM Prepiped Gas Manifold PGM Prepiped Gas Manifold PGM-1 Edition 03-09 Prepiped and assembled for easy installation Suitable for single and multiple burner applications Automatic safety shutoff valves with visual indication and

More information

THE FIRING LINE Honeywell Flame Rod and Pilot Burner Cross Reference

THE FIRING LINE Honeywell Flame Rod and Pilot Burner Cross Reference THE FIRING LINE Honeywell Flame Rod and Pilot Burner Cross Reference Cross Reference Data: HONEYWELL PYRONICS C7004 page EN page 9 C700 page 4EN page 9 C7007 page PROTECTION CONTROLS C7008 page R page

More information

Replacing the Meter Body / Process Head Parts

Replacing the Meter Body / Process Head Parts Replacing the Meter Body / Process Head Parts ST 700 and ST 800 Pressure Transmitters and SMV800 Multivariable Transmitter - Instruction sheet Document Number: 34-ST-33-70 Effective Date: 5/27/2016 (Process

More information

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL212HH

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL212HH Exploded View Pumps 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 660-567 Please visit our website at Page Number Reference www.dekkervacuum.com DWG //05 Exploded View 95 SOUTH WOODLAND AVENUE, MICHIGAN

More information

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F.  Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Shafer Poppet Block Control

Shafer Poppet Block Control PBC-01102001 Rev. A January 2001 Shafer Poppet Block Control USASI SCHEMATIC Normally closed, double three-way poppet valve, with open exhaust, manual and pilot actuated. PILOT EXHAUST OR RETURN OIL PBC-01102001

More information

Description. Rhino EFD Bulk Unloader Packages

Description. Rhino EFD Bulk Unloader Packages Rhino EFD Bulk Unloader Packages Description See Figure. The Rhino EFD Pail and -Gallon Drum Bulk Unloader Packages consist of the following major components: Pump () Controls () Frame () Follower Plate

More information

SOUTHWEST OILFIELD PRODUCTS, INC.

SOUTHWEST OILFIELD PRODUCTS, INC. SOUTHWEST OILFIELD PRODUCTS, INC. MUD PUMP EXPENDABLE PARTS LIST OEM STYLE FLUID END FOR NATIONAL 14-P-220 MUD PUMP PERFORMANCE CHART PUMP MAX MAX STROKE LINER SIZE IN INCHES MODEL I.H.P. S.P.M. LENGTH

More information

Gas Convection Ovens UP TO

Gas Convection Ovens UP TO Gas Convection Ovens models SDG-, SDG-2 UP TO (serial#) 2052300xxxxx (date) 3-May-2 Phone (US & Canada): 800 427 6668 Fax (US & Canada): 800 36 7745 www.garland-group.com U_GO_PL_SUNFIRE_SDGSDG2 (Rev 8)

More information

HLP M10 HLP M10 (AFTER SERIAL # )

HLP M10 HLP M10 (AFTER SERIAL # ) HLP-1502-0M10 HLP-0703-0M10 (AFTER SERIAL #15023661) PUMP OIL GRADE: SAE30W Non-Detergent PUMP OIL CAPACITY: 11 oz. BTU INPUT: 200, 000 (Vapor Only) PRESSURE NOZZLE: HLP-0703-0M10: 5.5 HLP-1502-0M10: 3.0

More information