SPECIFICATION CATALOG. Commercial / to 6 Ton. Water Source/Geothermal Heat Pump

Size: px
Start display at page:

Download "SPECIFICATION CATALOG. Commercial / to 6 Ton. Water Source/Geothermal Heat Pump"

Transcription

1 SPEIFIATION ATALO ommercial / to 6 Ton 1 2 Water Source/eothermal Heat Pump

2

3 Table of ontents Model Nomenclature AHI Data The Versatec ompact Series Inside the Versatec ompact Series ontrols Application Notes Water Quality Installation Notes Vertical Dimensional Data Horizontal Dimensional Data Hanger Bracket Locations Physical Data Electrical Availability Electrical Data Blower Performance Data Selection Example eference alculations Legend and Notes Operating Limits orrection Factor Tables Pressure Drop Performance Data Wiring Schematics Engineering uide Specifications evision uide

4 Model Nomenclature UB V 036 T L A N 15 A 16 N A SS 23 * Model Type UB Versatec ompact abinet onfiguration n V Vertical H - Horizontal Unit apacity acit (MBTUH) 006, 009, 012, 015, 018, 024, 030, 036, (Vertical) 042, 048, 060, 070 Discharge onfiguration n T Top (Vertical) E End (Horizontal) S Side (Horizontal) eturn Air onfiguration n L Left ight Voltage /60/ /60/1 ( ) ) /60/3 ( ) 070) 4 460/60/3 /3 ( ) 5 575/60/3 /3 (PS Only ) 9 115/60/1 /1 ( ) efrigeration Option 0 None Blower Motor Options 0 PS Blower 1 Variable Speed EM Blower ( ) 4 5-Speed EM Blower ( ) 6 Variable Speed onstant Torque EM Blower ( ) 5 Water oil Options opper D Insulated opper N upronickel P Insulated upronickel Sound Kit A None B Sound Kit (Not Available on UBH ) Vintage * - Factory Use Only Non-Standard Options SS Standard Drain Pan Option 0 omposite, No Secondary onnection 1 omposite, Secondary onnection 2 Stainless Steel, No Secondary onnection 3 Stainless Steel, Secondary onnection Air oil Option 3 All-Aluminum, Uncoated 4 All-Aluminum, AlumiSeal TM Filter Option A MEV 4 B MEV 13 abinet Option 0 Unpainted abinet, Filter ail 1 Painted abinet, Filter ail 2 Unpainted abinet, 4-Sided Filter ack 3 Painted abinet, 4-Sided Filter ack Electrical Options 1 N No Phase uard, No Disconnect D No Phase uard, Disconnect P Phase uard, No Disconnect B Phase uard, Disconnect ontrol Options 2 A Aurora TM Base ontrol (AB) E Aurora TM UP DD ontroller F Aurora TM UP DD ontroller with LON Water ontrol Options 3 N None Water Flow egulator ( ) V 2-Way Valve ( ) B 2-Way Valve w/ Water Flow egulator ( ) W Waterside Economizer S Waterside Economizer w/ Water Flow egulator E Waterside Economizer w/ 2-Way Valve Waterside Economizer w/ 2-Way Valve & Water Flow egulator Note: 1 - Phase uard Only Available on /60/3 and 460/60/3 2-50VA transformer with Aurora Base ontrol, and 75VA transformer with Aurora UP control 3 - Waterside economizer option must be ordered with stainless steel drain pan and either 5-speed EM or variable speed EM ( ) 4 2 way valve, water flow regulator, economizer, disconnect, 2" filter and filter rack not available in UBV Blower Motor option 6" only available in 115/60/1 and /60/1. Note: See separate manual for economizer option 4

5 AHI Data PS Motors AHI/ASHAE/ISO English (IP) Units Model Flow ate gpm cfm AHI 500* Water Loop Heat Pump round Water Heat Pump round Loop Heat Pump IEE SHE EE OP Btuh/W Btuh/W ooling EWT 86 F apacity Btuh EE Btuh/W Heating EWT 68 F apacity Btuh OP ooling EWT 59 F apacity Btuh EE Btuh/W Heating EWT 50 F apacity Btuh OP ooling EWT 77 F apacity Btuh EE Btuh/W Heating EWT 32 F apacity Btuh , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , /9/18 ooling capacities based upon 80.6 F DB, 66.2 F WB entering air temperature Heating capacities based upon 68 F DB, 59 F WB entering air temperature All ratings based upon 208V operation OP Variable Speed EM, 5 Speed EM motor AHI/ASHAE/ISO English (IP) Units Model Flow ate gpm cfm AHI 500* Water Loop Heat Pump round Water Heat Pump round Loop Heat Pump ooling Heating ooling Heating ooling Heating IEE SHE EWT 86 F EWT 68 F EWT 59 F EWT 50 F EWT 77 F EWT 32 F EE OP Btuh/W Btuh/W apacity Btuh EE Btuh/W apacity Btuh OP apacity Btuh EE Btuh/W apacity Btuh OP apacity Btuh EE Btuh/W apacity Btuh , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , /9/18 ooling capacities based upon 80.6 F DB, 66.2 F WB entering air temperature Heating capacities based upon 68 F DB, 59 F WB entering air temperature All ratings based upon 208V operation The purpose of this standard is to establish an IEE and SHE Method of alculation for Water/Brine Source Heat Pumps. This standard utilizes the Published, ertified Data, of performance standard ISO/AHI/ANSI/ASHAE :1998, and includes the definitions; rating requirements; minimum data requirements for Published atings; marking and nameplate data; and conformance conditions required. OP All Versatec ompact Series product is safety listed under UL1995 thru ETL and performance listed with AHI in accordance with standard

6 AHI Data cont. The performance standard AHI/ASHAE/ISO became effective January 1, 2000 and replaces AHI Standards 320, 325, and 330. This new standard has three major categories: Water Loop (comparable to AI 320), round Water (AI 325), and round Loop (AI 330). Although these standards are similar there are some differences: Unit of Measure: The ooling OP The cooling efficiency is measured in EE (US version measured in Btu/h per Watt. The Metric version is measured in a cooling OP (Watt per Watt) similar to the traditional OP measurement. Water onditions Differences Entering water temperatures have changed to reflect the centigrade temperature scale. For instance the water loop heating test is performed with 68 F (20 ) water rounded down from the old 70 F (21.1 ). Air onditions Differences Entering air temperatures have also changed (rounded down) to reflect the centigrade temperature scale. For instance the cooling tests are performed with 80.6 F (27 ) dry bulb and 66.2 F (19 ) wet bulb entering air instead of the traditional 80 F (26.7 ) DB and 67 F (19.4 ) WB entering air temperatures. 80.6/66.2 data may be converted to 80/67 using the entering air correction table. This represents a significantly lower relative humidity than the old 80/67 of 50% and will result in lower latent capacities. Pump Power orrection alculation Within each model, only one water flow rate is specified for all three groups and pumping Watts are calculated using the following formula. This additional power is added onto the existing power consumption. Pump power correction = (gpm x ) x (Press Drop x 2990) / 300 Where gpm is waterflow in gpm and Press Drop is the pressure drop through the unit heat exchanger at rated water flow in feet of head. Blower Power orrection alculation Blower power is corrected to zero external static pressure using the following equation. The nominal airflow is rated at a specific external static pressure. This effectively reduces the power consumption of the unit and increases cooling capacity but decreases heating capacity. These Watts are significant enough in most cases to increase EE and OPs fairly dramatically over AI 320, 325, and 330 ratings. Blower Power orrection = (cfm x 0.472) x (esp x 249) / 300 Where cfm is airflow in cfm and esp is the external static pressure at rated airflow in inches of water gauge. ISO apacity and Efficiency alculations The following equations illustrate cooling calculations: ISO ooling apacity = ooling apacity (Btu/h) + (Blower Power orrection (Watts) x 3.412) ISO EE Efficiency (W/W) = ISO ooling apacity (Btu/h) x / [Power Input (Watts) - Blower Power orrection (Watts) + Pump Power orrection (Watt)] The following equations illustrate heating calculations: ISO Heating apacity = Heating apacity (Btu/h) - (Blower Power orrection (Watts) x 3.412) ISO OP Efficiency (W/W) = ISO Heating apacity (Btu/h) x / [Power Input (Watts) - Blower Power orrection (Watts) + Pump Power orrection (Watt)] omparison of Test onditions AI 320 ISO/AHI WLHP AI 325 ISO/AHI WHP AI 330 onversions: Airflow (lps) = cfm x 0.472; Water Flow (lps) = gpm x ; esp (Pascals) = esp (in wg) x 249; Press Drop (Pascals) = Press Drop (ft hd) x 2990 ISO/AHI LHP ooling Entering Air - DB/WB F 80/ / / / / /66.2 Entering Water - F / Fluid Flow ate * ** ** ** ** ** Heating Entering Air - DB/WB F Entering Water - F / Fluid Flow ate * ** ** ** ** ** Note *: Flow rate is set by 10 F rise in standard cooling test Note **: Flow rate is specified by the manufacturer Part load entering water conditions not shown. WLHP = Water Loop Heat Pump; WHP = round Water Heat Pump; LHP = round Loop Heat Pump 6

7 The Versatec ompact Series The Versatec ompact is the latest in WaterFurnace s efforts to be the best in the water source heat pump industry. The Versatec ompact raises the bar for boiler/tower applications by providing flexibility and efficiency into a compact cabinet at a competitive price. A compact cabinet is important when choosing a replacement heat pump. Many water source heat pumps of the s were relatively low efficiency models with a small footprint. Once they are installed in a building and piping and ductwork is piped around the unit replacement with a larger footprint is nearly impossible. The Versatec ompact combines the high efficiency of 21 st century product in a footprint that matches a 1980 heat pump for easy replacement. The chart below shows a comparison of a typical 1980 legacy wshp and current competitor data versus the Versatec ompact Series. Year WaterSource Heat Pump WLHP EE (PS/EM) Height [in.] This full range product offers all the standard commercial voltages using high efficiency rotary and scroll compressors along with either 3-speed permanent split-capacitor (PS), 5-speed EM, or variable speed EM blower motors. Versatec ompact Highlights High efficiency performance - With PS Blower Motor Up to 14.0 EE and 4.7 OP (ISO/AHI WLHP) - With Variable Speed EM Blower Motor Up to 14.7 EE and 4.9 OP (ISO/AHI WLHP) - With 5-Speed EM Blower Motor Up to 14.7 EE and 4.9 OP (ISO/AHI WLHP) Unrivaled cabinet footprint that can fit most application requirements - A four ton horizontal unit less than four feet long means the smallest horizontal cabinets in the industry! All-Aluminum rifled tube-and-fin air coils are not susceptible to formicary corrosion. Dedicated 460V 5-Speed EM does not require use of a neutral! Aurora Base microprocessor control capable of operating 5-speed EM or variable speed EM with internally mounted 2-way valve Flexible factory installed options - orrosion-proof composite or stainless steel drain pan; including internally mounted secondary drain connection option - opper or cupronickel heat exchanger and optional low temperature insulation - Filter options: standard 1 in. MEV 4 or option 2 in. MEV 13 with either filter rails or option deluxe four sided filter rack that is field switchable between 1 in. and 2 in. - Aurora Base ontrol or with Aurora UP with N2, BAnet, or optional LonWorks card - Factory mounted internal water valve and/or flow regulator for variable speed pumping systems saves on installation costs - Other options: Sound Kit, oated Air oil, Phase uard, Internally Mounted Non-fused Power Disconnect Width [in.] Length [in.] 3 Ton Horizontal WSHP 1980 Typical Legacy Unit 11.6/ ompetitor A ompact Unit 14.2/ ompetitor B ompact Unit 13.5/ ompetitor ompact Unit 13.7/ Versatec ompact 14/ Ton Horizontal WSHP 1980 Typical Legacy Unit 10.4/ ompetitor A ompact Unit 13/ ompetitor B ompact Unit 13.3/ ompetitor ompact Unit 13.13/ Versatec ompact 13/ Vertical Versatec ompact Series Models UBV (0.5-6 tons) Single Speed Horizontal Versatec ompact Series Models UBH (0.5-6 tons) Single Speed 7

8 The Versatec ompact Series cont. Product Features: Vertical abinet Versatec ompact vertical units are designed for high efficiency, maximum flexibility, and primary servicing from the front. Standard filter rail, field switchable for 1 in. or 2 in. filters Optional factory mounted deluxe filter rack (shown), field switchable for 1 in. or 2 in. filters emovable inlet rings for easy blower removal Insulated divider panel Oversized rifled tube/ lanced fin all-aluminum air coil (optional AlumiSeal TM coil coating). Optional ThermaShield coated coaxial heat exchanger orrosion-resistant, composite drain pan with overflow protection, optional secondary drain connection Optional stainless steel drain pan with overflow protection, optional secondary drain connection High efficiency rotary or scroll compressor Internally trapped condensate line Microprocessor control Aurora - Standard Fault and status LEDs (Aurora Base ontrol only) Fault and status LEDs (Aurora Base ontrol only) AID Tool for diagnosing and controlling the Aurora control A true left and right return option is available. 8

9 The Versatec ompact Series cont. Product Features: Horizontal abinet Horizontal units are designed for compact installation, maximum flexibility, and primary servicing from the front. Oversized rifled tube/lanced fin all-aluminum air coil (optional AlumiSeal coil coating). Smallest abinet in Industry Optional factory mounted filter rail accepts 1 in. and 2 in. filters (field switchable) Fault and diagnostic LEDs (Aurora Base ontrol only) Optional ThermaShield coated coaxial heat exchanger Microprocessor control AB - Standard UP - Optional Easily removable control box High efficiency rotary or scroll compressor Four blower deck options are available. Factory or field conversion option of end or side discharge using switchable access panels and a factory only option of true left or right return air coil. Left hand return with end discharge Left hand return with side discharge ight hand return with end discharge ight hand return with side discharge 9

10 The Versatec ompact Series cont. Flexible Product with Several Standard Options ompact cabinet design, vertical and horizontal with true left and right return configurations Horizontal end and side discharge with vertical top discharge air configurations apacities of 6,000 through 70,000 Btu/h All commercial voltages including 115/60/1, /60/1, /60/1, /60/3, 460/60/3, and 575/60/3. 3 speed PS, 5 speed EM, or optional variable speed EM blower motors All-Aluminum rifled tube-and-fin air coil are not susceptible to formicary corrosion Optional AlumiSeal air coil e-coating for improved condensate runoff Extended range insulation option Super Quiet Sound Package, including multi-density compressor blanket Quiet rotary/scroll compressors 2-dimension refrigerant piping vibration loops to isolate the compressor Discharge mufflers on sizes Heavy gauge cabinet and 4 vibration isolating hanger brackets Internally mounted water flow regulator and/or water solenoid valve for variable speed pumping systems Standard Aurora Base ontrol or UP D ontrol with standard N2, ModBus, BAnet, or optional LonWorks card Phase guard with optional dial disconnect Polymer composite drain pan or stainless steel drain pan with optional secondary drain connection 1 in. MEV 4 or 2 in. MEV 13 filters Other options are available by special request through WaterFurnace ommercial Sales. High Efficiency The Versatec ompact Series is a high efficiency water source heat pump in a compact vertical and horizontal cabinet. The product features highly efficient and reliable single capacity rotary/scroll compressors mated with large blowers. These blowers are driven by efficient 3 speed PS blower motors, 5-speed EM blower motors, or highly efficient variable speed EM blower motors. Super Quiet Option An optional Super Quiet Sound Package is also available for a modest cost and features multi-density laminate lined compressor blanket designed to completely surround the compressor and suppress low frequency noise. Indoor Air Quality (IAQ) All Versatec ompact Series features several IAQ benefits: orrosion-free composite double-sloped drain pan to eliminate standing water and prevent bacterial growth A washable surface on insulation in all air handler compartments to allow cleanability and inhibit bacteria growth. Optional non-fibrous closed cell insulation is also available for more sensitive applications by special request through commercial sales.. Open filter rail comes standard for non-ducted return applications. Filter rail is field switchable from 1 in. to 2 in. [2.54 to 5.1 cm] for more filter options. Optional factory mounted, four sided, deluxe filter rack that is field switchable from 1 in. to 2 in. [2.54 to 5.1 cm] is available for ducted return applications. Standard supplied filter is a pleated MEV 4, 1 in. [2.54 cm]. An optional low static high efficiency 2 in. [5.1 cm] MEV 13, for LEED certification points, is also available. Internally Mounted Solenoid Valve Option When variable speed circulating pump systems are designed, low pressure drop (high v) solenoid valves are specified at each unit to vary the pump according to flow required. It is important that these valves be low pressure drop to avoid unwanted pump watts. This option factory installs this valve inside the unit. Secondary Drain onnection Option Some local building authority s interpretation of codes require more condensate overflow protection than standard microprocessor based condensate sensors offer. In these areas a full secondary drain pan might be required causing both increased cost and unit service access issues. In many of these cases a secondary drain connection option can be added to the unit to pass this local interpretation of condensate drain redundancy. This option adds a second PV drain connection to the drain pan at a higher level. Phase uard Monitor Factory mounted phase guard device is available to protect the compressor against loss of phase. 10

11 The Versatec ompact Series cont. Aurora Base ontrol The Aurora Base ontrol (AB) System is a complete residential and commercial comfort system that brings all aspects of the HVA system into one cohesive module network. Aurora uses the Modbus communication protocol to communicate between modules. Each module contains the logic to control all features that are connected to the module. The Aurora Base ontrol (AB) has two Modbus channels. The first channel is configured as a master for connecting to devices such as a communicating thermostat, expansion board, or other slave devices. The second channel is configured as a slave for connecting the Aurora Interface Diagnostic (AID) Tool. Aurora Unitary Protocol onverter (UP) The optional Aurora UP control provides unparalleled capability in several areas including energy, refrigerant, and performance monitoring, humidity, energy management, and service diagnostics, and then communicates it all thru standard DD protocols like N2, Lon and BAnet MS/TP. The most unique feature is integration of the Aurora Base ontrol and UP into the Versatec ompact as an integrated heat Pump and DD controller providing both a cost advantage and providing features not typically found on WSHP controls. This integration allows heat pump monitoring sensors, status and service diagnosis faults to be communicated thru the DD direct to the building automation system (BAS), giving building supervisors detailed and accurate information on every piece of equipment without removing an access panel! ontrol eneral Description Application Display/Interface Protocol Aurora Base ontrol The AB microprocessor provides all the features necessary to operate today s standard WSHPs that utilize dual capacity compressors and variable speed EM/5 speed EM blower motors with hot gas reheat. This control can communicate to a handheld diagnostic tool to help the installing contractor or service technician with equipment setup and service. By utilizing Modbus TU communication protocol, the AB board can communicate with additional devices on the Aurora network Used for residential and commercial applications that use single or dual capacity compressors with PS, 5-speed EM, or variable speed EM blower motors. This base control can also communicate to the AID Tool to display faults, inputs/outputs, and software revision. ommercial features such as hot gas reheat, slow opening water valve, and random start are also capable with the AB board. Optional AID toll can be used for field service. Standalone Aurora Base ontrol w/up BAnet or N2 The Aurora Unitary Protocol onverter (UP) is an integrated solution and communicates directly with the Aurora Heat Pump ontrols and allows access/control of a variety of internal Aurora heat pump operations such as sensors, relay operation, faults and other information. In turn, the UP then converts internal Aurora Modbus protocol to BAnet MS/TP, or N2 protocols and communicates to the BAS system. This provides the great benefit of complete control integration and a myriad of information available to the BAS from the heat pump control. Plus it also allows individual unit configuration such as EM fan speeds or freeze protection setting directly over the BAS without the need for access to the actual heat pump. The Aurora UP is implemented with the Aurora Base ontroller (AB) heat pump control into our latest water source heat pumps. All Internal Aurora points are accessible to the UP via firmware providing an integrated solution. All zone temperatures and zone sensors are connected to the UP on an Net bus, simplifying hook up at the unit. Net sensors can include a combination of zone temperature and humidity, O2, and VO sensors. The UP includes built-in support for a custom configurable keypad/display unit. Optional Equipment Touch display BAnet MS/ TP or N2 Open (DIP selectable) Aurora Base ontrol w/up LonWorks The Aurora Unitary Protocol onverter (UP) is an integrated solution and communicates directly with the Aurora Heat Pump ontrols and allows access/control of a variety of internal Aurora heat pump operations such as sensors, relay operation, faults and other information. In turn, the UP then converts internal Aurora Modbus protocol to LONWorks protocol and communicates to the BAS system. The Aurora UP is implemented with the Aurora Base ontroller (AB) heat pump control into our latest water source heat pumps. All Internal Aurora points are accessible to the UP via firmware providing an integrated solution. All zone temperatures and zone sensors are connected to the UP on an Net bus, simplifying hook up at the unit. Net sensors can include a combination of zone temperature and humidity, O2, and VO sensors. The UP includes built-in support for a custom configurable keypad/display unit. Optional Equipment Touch display LonWorks AXB Expansion Board (Future Availability) Aurora Advanced ontrol adds the Aurora AXB expansion board and provides added I/O and standard features. AXB can be added to any of the above packages to enhance the I/O of the controls. efrigeration Monitoring provides Suction and discharge pressure, Suction, liquid line temps and superheat and subcooling. Performance Monitoring provides entering and leaving loop water temperatures, loop flow rate as well as heat of extraction or rejection rate into the loop. Energy Monitoring provides realtime power measurement (Watt) of compressor, fan, auxiliary heat and zone pump. Plus many more I/O options 11

12 The Versatec ompact Series cont. Electrical Disconnect An optional factory mounted, internally (UBV/H externally mounted) wired disconnect is available to avoid scheduling problems with the electrical contractor. Other features include: Non-fused, dial type switch with on/off position ompact design Lockout/Tagout feature to keep the unit off during service Low eiling Height equirement (Horizontal ) Utilizing a raised drain pan, the condensate drain trap on horizontal models 006 through 012 can be made within the height of the cabinet. This allows the Versatec ompact to be installed without any additional ceiling height, or in areas where ceiling height is at a premium. The Versatec ompact models have the lowest ceiling height installation requirements of any AHI listed manufacturer. Factory Quality All refrigerant brazing is performed in a nitrogen environment. omputer controlled deep vacuum and refrigerant charging system. All joints are leak detected for maximum leak rate of less than 1/4 oz. per year. omputer bar code equipped assembly line ensures all components are correct. All units are computer run-tested with water to verify both function and performance. 12

13 Inside the Versatec ompact Series efrigerant Versatec ompact products all feature zero ozone depletion and low global warming potential refrigerant -410A. abinet All units are constructed of corrosion resistant galvanized sheet metal. One large lift-out access panel provides access to the compressor and air handler section to allow servicing of blower motor, blower, and drain pan. efrigerant circuit is designed to allow primary serviceability from the front. Six (6) horizontal and six (6) vertical cabinets are provided for application flexibility. The blower motor and blower can be completely serviced or replaced without removal of the unit. Service of the blower and blower motor is made easier via the removable orifice ring on the housing. Flexible configurations include four (4) blower deck options for horizontals and a true left and right return on both horizontal and vertical and the smallest horizontal cabinet in the industry. Filter ack All units come standard with an open filter rail, for use in open return applications, or an optional deluxe filter rack/ duct collar for use with ducted returns. Both filter options are field switchable between 1 in. [2.54 cm] and 2 in. [5.1 cm] thick filters for filter flexibility. A MEV 4, 1 in. [2.54 cm] is standard with an optional 2 in. [5.1 cm] MEV 13 for LEED certification points and high efficiency filtration. Horizontal Hanger Kits Each horizontal unit includes a hanger kit to meet seismic specification requirements while still allowing filter access. Drain Pan All condensate connections are PV glue for economical corrosion free connections. Bacteria resistant composite drain pan is sloped to promote complete drainage and will never rust or corrode. omplete drainage helps to inhibit bacterial or microbial growth. Vertical units feature an internally trapped condensate line using clear PV hose for easy inspection and reduced installation cost. Optional factory installed stainless steel drain pans are also available. Electrical Box Unit controls feature quick connect wiring harnesses for easy servicing. Separate knockouts for low voltage and two sides of the electrical corner post for easy access to the control box. 50VA or large 75VA transformer assures adequate controls power for accessories. ompressors The Versatec ompact features high efficiency -410A rotary ( ) and scroll ( ) compressors. These types of compressors provide both high efficiency and great reliability. 13

14 Inside the Versatec ompact Series cont. Air Handler Insulation Washable air handler insulation surface provides cleanability to further enhance IAQ. Thermostatic Expansion Valve All Versatec ompact models utilize a balanced port bidirectional thermostatic expansion valve (TXV) for refrigerant metering. This allows precise refrigerant flow in a wide range of entering water variation (20 to 120 F [-7 to 49 ]) found in geothermal systems. The TXV is located in the compressor compartment for easy access. Service onnections and Serviceability Two Schrader service ports are provided in every unit. The suction side and discharge side ports are for field charging and servicing access. All valves are 7/16 in. SAE connections. All water and electrical connections are made from the front of the unit. Unit is designed for front access serviceability. 4-Way eversing Valve Versatec ompact units feature a reliable all-brass pilot operated refrigerant reversing valve. The reversing valve operation is limited to change of mode by the control to enhance reliability. Water-to-efrigerant oaxial Heat Exchanger oil oaxial refrigerant to water heat exchangers provide unparalleled efficiency. The coaxes are designed for low pressure drop and low flow rates. All coaxes are pressure rated to 450 psi water side and 600 psi on the refrigerant side. Optional ThermaShield coating is available on the water-to-refrigerant heat exchanger to prevent condensation in low temperature loop operation. All-Aluminum Air oil Beginning in Fall of 2013, all models in the Versatec ompact line began shipping with allaluminum air coils. WaterFurnace is the first manufacturer to offer an all-aluminum round-tube-andfin air coil in a packaged water source heat pump. These air coils are constructed of lanced fin and rifled tube aluminum that is not susceptible to formicary corrosion. For additional condensate runoff and meeting project specifications, an optional AlumiSeal e-coating is available. 14

15 Inside the Versatec ompact Series cont. Blower Motor and Housing High efficiency low rpm galvanized direct drive blower featuring 3 speed permanently split capacitor (PS) motor, 5-speed EM motor, and optional variable speed EM blower motor. The variable speed EM motor is controlled directly through the unit's microprocessor control. The lower rpm blower also reduces air noise. All PS and 5-speed EM motors have speed selection terminal strip on the motor for easy speed change. All motors are vibration isolated to reduce noise. Horizontal units can be field converted from end to side discharge as well. NOTE: 460V 5-speed EM blower motor does not require a neutral wire. 5-Speed EM onstant Torque Motors The 5-speed EM is a onstant Torque EM motor and delivers air flow similar to a PS but operates as efficiently as an variable speed EM Motor. Because it s an EM Motor, the 5-speed EM can ramp slowly up or down like the variable speed EM Motor. There are 5 possible speed taps available on the 5-speed motor with #1 being the lowest airflow and #5 being the highest airflow. These speed selections are preset at the time of manufacture and are easily changed in the field if necessary. 5-Speed EM Benefits: - High efficiency - Soft start - 5 speeds with up to 4 speeds on-line - Built in logic allows air flow to change with, Y1, Y2 and W signals - Super efficient low airflow continuous blower setting () 15

16 ontrols - Aurora Base ontrol Aurora Base ontrol NOTE: efer to the Aurora Base ontrol Application and Troubleshooting uide and the Instruction uide: Aurora Interface and Diagnostics (AID) Tool for additional information. ontrol Features Software AB Standard Version 3.0 Single or Dual apacity ompressors Either single or dual capacity compressors can be operated. Variable Speed EM Blower Motor Option (If Applicable) A Variable Speed EM blower motor can be driven directly using the onboard PWM output. Four blower speeds are available based upon the, Y1, Y2, and W input signals to the board. The blower speeds can be changed either by the EM manual configurations mode method or by using the Aurora AID Tool directly. All four blower speeds can be set to the same speed if desired. 5-Speed EM Blower Motor Option (If Applicable) A 5-Speed EM blower motor will be driven directly using the thermostat connections. Any of the, Y1, or Y2/W signals can drive any of the 5 available pre-programmed blower speeds on the motor. All 5 Series "" vintage units will be wired this way at the factory. Other ontrol Features andom start at power up Anti-short cycle protection High and low pressure cutouts Loss of charge Water coil freeze detection Air coil freeze detection Over/under voltage protection ondensate overflow sensor Load shed Dehumidification (where applicable) Emergency shutdown Hot gas reheat operation (where applicable) Diagnostic LED Test mode push button switch Two auxiliary electric heat outputs Alarm output Accessory output with N.O. and N.. Two Modbus communication Ports Field Selectable Options via Hardware DIP Switch (SW1) Test/onfiguration Button (See SW1 Operation Table) Test Mode The control is placed in the test mode by holding the push button switch SW1 for 2-5 seconds. In test mode most of the control timings will be shortened by a factor of sixteen (16). LED3 (green) will flash at 1 second on and 1 second off. Additionally, when entering test mode LED1 (red) will flash the last lockout one time. Test mode will automatically time out after 30 minutes. Test mode can be exited by pressing and holding the SW1 button for 2 to 5 seconds or by cycling the power. NOTE: Test mode will automatically be exited after 30 minutes. Variable Speed EM onfiguration Mode (If Applicable) The control is placed in the EM configuration mode by holding the pushbutton switch SW1 for 5 to 10 seconds, the high, low, and EM speeds can be selected by following the LED display lights. LED2 (yellow) will fast flash when entering the EM configuration. When setting speed LED3 (green) will be continuously lit, for low speed LED1 (red) will be continuously lit, and for high speed both LED3 (green) and LED1 (red) will be continuously lit. During the EM configuration mode LED2 (yellow) will flash each of the 12 possible blower speeds 3 times. When the desired speed is flashed press SW1, LED2 will fast flash until SW1 is released. speed has now been selected. Next select low speed, and high speed blower selections following the same process above. After third selection has been made, the control will exit the EM configuration mode. Aux fan speed will remain at default or current setting and requires the AID Tool for adjustment. eset onfiguration Mode The control is placed in reset configuration mode by holding the push button switch SW1 for 50 to 60 seconds. This will reset all configuration settings and the EEPOM back to the factory default settings. LED3 (green) will turn off when entering reset configuration mode. Once LED3 (green) turns off, release SW1 and the control will reset. DIP Switch (SW2) SW2-1 FP1 Selection Low water coil temperature limit setting for freeze detection. On = 30 F; Off = 15 F. SW2-2 FP2 Selection On = 30 F; Off = N/A SW2-3 V O/B - thermostat type. Heat pump thermostats with O output in cooling or B output in Heating can be selected. On = O; Off = B. SW2-4 Access elay Operation (P2) and 2-5 Access elay Operation SW2-4 SW2-5 ycle with Blower ON ON ycle with ompressor OFF OFF Water Valve Slow Opening ON OFF ycle with omm. T-stat Hum md OFF ON 16

17 ontrols - Aurora Base ontrol cont. ycle with Blower - The accessory relay will cycle with the blower output. ycle with ompressor - The accessory relay will cycle with the compressor output. Water Valve Slow Opening - The accessory relay will cycle and delay both the blower and compressor output for 90 seconds. SW2-6 Operation selection of single or dual capacity compressor. On = Single Stage; Off = Dual apacity SW2-7 Lockout and Alarm Outputs (P2) selection of a continuous or pulsed output for both the LO and ALM Outputs. On = ontinuous; Off = Pulsed SW2-8 Future Use Alarm Jumper lip Selection From the factory, ALM is connected to 24 VA via JW2. By cutting JW2, ALM becomes a dry contact connected to AL. Variable Speed EM Blower Speeds The blower speeds can be changed either by using the EM manual configurations mode method or by using the Aurora AID Tool directly (see Instruction uide: Aurora Interface and Diagnostics (AID) Tool topic). Field Selectable Options via Software (Selectable via the Aurora AID Tool) EM Blower Speeds An EM blower motor can be driven directly using the onboard PWM output. Four blower speeds are available, based upon the, Y1 (low), Y2 (high), and Aux input signals to the board. The blower speeds can be changed either by the EM manual configurations mode method (see EM onfiguration Mode topic) or by using the Aurora AID Tool directly. All four blower speeds can be set to the same speed if desired. Aux blower speed will remain at default or current setting and requires the AID Tool for adjustment. Safety Features The following safety features are provided to protect the compressor, heat exchangers, wiring and other components from damage caused by operation outside of design conditions. Fuse a 3 amp automotive type plug-in fuse provides protection against short circuit or overload conditions. Anti-Short ycle Protection 4 minute anti-short cycle protection for the compressor. andom Start 5 to 80 second random start upon power up. Fault etry in the fault condition, the control will stage off the outputs and then try again to satisfy the thermostat Y input call. Once the thermostat input calls are satisfied, the control will continue on as if no fault occurred. If 3 consecutive faults occur without satisfying the thermostat Y input call, then the control will go to Lockout mode. Lockout when locked out, the blower will operate continuously in speed, and PS blower motor output will remain on. The Alarm output (ALM) and Lockout output (L) will be turned on. The fault type identification display LED1 (ed) shall flash the fault code. To reset lockout conditions with SW2-8 On, thermostat inputs Y1, Y2, and W must be removed for at least 3 seconds. To reset lockout conditions with SW2-8 Off, thermostat inputs Y1, Y2, W, and DH must be removed for at least 3 seconds. Lockout may also be reset by turning power off for at least 30 seconds or by enabling the emergency shutdown input for at least 3 seconds. Lockout With Emergency Heat - if the control is locked out in the heating mode, and a Y2 or W input is received, the control will operate in the emergency heat mode while the compressor is locked out. The first emergency heat output will be energized 10 seconds after the W input is received, and the blower will shift to high speed. If the control remains locked out, and the W input is present, additional stage of emergency heat will stage on after 2 minutes. When the W input is removed, all of the emergency heat outputs will turn off, and the EM blower will shift to speed and PS blower motor output will remain on. High Pressure fault is recognized when the Normally losed High Pressure Switch, P4-9/10 opens, no matter how momentarily. The High Pressure Switch is electrically in series with the ompressor ontactor and serves as a hardwired limit switch if an overpressure condition should occur. Low Pressure - fault is recognized when the Normally losed Low Pressure Switch, P4-7/8 is continuously open for 30 seconds. losure of the LPS any time during the 30 second recognition time restarts the 30 second continuous open requirement. A continuously open LPS shall not be recognized during the 2 minute startup bypass time. Loss of harge fault is recognized when the Normally losed Low Pressure Switch, P4-7/8 is open prior to the compressor starting. ondensate Overflow - fault is recognized when the impedance between this line and 24 VA common or chassis ground drops below 100K ohms for 30 seconds continuously. Freeze Detection (oax) - set points shall be either 30 F or 15 F. When the thermistor temperature drops below the selected set point, the control shall begin counting down the 30 seconds delay. If the thermistor value rises above the selected set point, then the count should reset. The resistance value must remain below the selected set point for the entire length of the appropriate delay to be recognized as a fault. This fault will be ignored for the initial 2 minutes of the compressor run time. Freeze Detection (Air oil) - uses the FP2 input to protect against ice formation on the air coil. The FP2 input will operate exactly like FP1 except that the set point is 30 degrees and is not field adjustable. 17

18 ontrols - Aurora Base ontrol cont. Over/Under Voltage Shutdown - An over/under voltage condition exists when the control voltage is outside the range of 18 VA to 30 VA. If the over/under voltage shutdown lasts for 15 minutes, the lockout and alarm relay will be energized. Over/under voltage shutdown is selfresetting in that if the voltage comes back within range of 18 VA to 30 VA for at least 0.5 seconds, then normal operation is restored. Operation Description Power Up - The unit will not operate until all the inputs and safety controls are checked for normal conditions. The unit has a 5 to 80 second random start delay at power up. Then the compressor has a 4 minute anti-short cycle delay after the random start delay. Standby In standby mode, Y1, Y2, W, DH, and are not active. Input O may be active. The blower and compressor will be off. Heating Operation Single ompressor Heating, 2nd Stage (Y1, Y2) The compressor will be staged to full capacity 20 seconds after Y2 input is received. The EM blower will shift to high speed seconds after the Y2 input is received. Dual ompressor Heating, 2nd Stage (Y1, Y2) In dual compressor operation, two AB boards used in 24 VA operation, there will be a Y2 call to the Y1 input on the second AB. The compressor will stage to full capacity 30 seconds after Y1 input is received to the second board. Single ompressor Heating, 3rd Stage (Y1, Y2, W) The hot water pump is de-energized and the first stage of electric heat is energized 10 seconds after the W command is received. If the demand continues the second stage of electric heat will be energized after 5 minutes. Dual ompressor Heating, 3rd Stage (Y1, Y2, W) - The first stage of electric heat is energized 10 seconds after the W command is received. If the demand continues the second stage of electric heat will be energized after 5 minutes Emergency Heat (W) - The blower will be started on speed, 10 seconds later the first stage of electric heat will be turned on. 5 seconds after the first stage of electric heat is energized the blower will shift to Aux speed. If the emergency heat demand is not satisfied after 2 minutes the second electric heat stage will be energized. ooling Operation In all cooling operations, the reversing valve directly tracks the O input. Thus, anytime the O input is present, the reversing valve will be energized. Single ompressor ooling, 2nd Stage (Y1, Y2, 0) The compressor will be staged to full capacity 20 seconds after Y2 input was received. The EM blower will shift to high speed 15 seconds after the Y2 input was received. Dual ompressor ooling, 2nd Stage (Y1, Y2, O) In dual compressor operation, two AB boards used in 24 VA operation, there will be a Y2 call to the Y1 input on the second AB. The compressor will stage to full capacity 30 seconds after Y1 input is received to the second board. Blower () - The blower will start immediately upon receiving a thermostat command. If there are no other commands from the thermostat the EM will run on speed until the command is removed. egardless of blower input () from the thermostat, the blower will remain on for 30 seconds at the end of each heating, cooling, and emergency heat cycle. Dehumidification (Y1, O, DH or Y1, Y2, O, DH) - When a DH command is received from the thermostat during a compressor call for cooling the EM blower speed will be reduced by 15% to increase dehumidification. Emergency Shutdown - Four (4) seconds after a valid ES input, P2-7 is present, all control outputs will be turned off and remain off until the emergency shutdown input is no longer present. The first time that the compressor is started after the control exits the emergency shutdown mode, there will be an anti-short cycle delay followed by a random start delay. Input must be tied to common to activate. ontinuous Blower Operation - The blower output will be energized any time the control has a input present, unless the control has an emergency shutdown input present. The blower output will be turned off when input is removed. Load Shed - The LS input disables all outputs with the exception of the blower output. When the LS input has been cleared, the anti-short cycle timer and random start timer will be initiated. Input must be tied to common to activate. Blower () - The blower will start immediately upon receiving a thermostat command. If there are no other commands from the thermostat the EM will run on speed until the command is removed. egardless of blower input () from the thermostat, the blower will remain on for 30 seconds at the end of each heating cycle. 18

19 ontrols - Aurora Base ontrol cont. Aurora Base ontrol LED Displays These three LEDs display the status, configuration, and fault codes for the control. These can also be read in plain English via the Aurora AID Tool. Status LED (LED3, reen) Description of Operation Fault LED, reen Normal Mode ON ontrol is Non-functional OFF Test Mode Slow Flash Lockout Active Fast Flash Dehumidification Mode Flash ode 2 (Future Use) Flash ode 3 (Future Use) Flash ode 4 Load Shed Flash ode 5 ESD Flash ode 6 (Future Use) Flash ode 7 onfiguration LED (LED2, Yellow) Description of Operation No Software Overwritten DIP Switch was Overwritten EM onfiguration Mode Fault LED (LED1, ed) ed Fault LED onfiguration LED, Yellow Flashing EM Setting Slow Flash Fast Flash LED Flash ode* Lockout eset/ emove Normal - No Faults OFF Fault - Input 1 No Auto Fault - High Pressure 2 Yes Hard or Soft Fault - Low Pressure 3 Yes Hard or Soft Fault - Freeze Detection FP2 4 Yes Hard or Soft Fault - Freeze Detection FP1 5 Yes Hard or Soft Fault - ondensate Overflow 7 Yes Hard or Soft Fault - Over/Under Voltage 8 No Auto Fault - FP1 & FP2 Sensor Error 11 Yes Hard or Soft NOTE: All codes >11 use long flash for tens digit and short flash for the ones digit. 20, 30, 40, 50, etc. are skipped. AB Basic Faults Aurora Interface and Diagnostics (AID) Tool The Aurora Interface and Diagnostics (AID) Tool is a device that is a member of the Aurora network. The AID Tool is used to troubleshoot equipment which uses the Aurora control via Modbus TU communication. The AID Tool provides diagnostics, fault management, EM setup, and system configuration capabilities to the Aurora family of controls. An AID Tool is recommended, although not required, for EM airflow settings. The AID Tool simply plugs into the exterior of the cabinet in the AID Tool port. AB ontrol Board Layout 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F Factory Factory P2 P4 P5 PWM FM EM PWM P13 SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Fi eld onnections Faul t LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal P9 LO P1 LED1 Factory Use P11 AUOA BASE ONTOL Off FP1 15 o F/30 o F FP2 15 o F/30 o F V B/O A Dip 4 Factory Fan onnection O/B Y1 Y2 Fi eld onnections 8 SW2 W On 1 LED2 2 Y 3 onfig DH om1 om2 3A-Fuse P3 Factory P6 S485 Exp P7 S 485 P8 S485 NET EH1 EH2 EH1 O N/A (+) (-) ES LS ALM AL A c A no A nc LO O/B Y1 Y2 W DH 19

20 ontrols - UP DD ontrol (optional) Aurora UP ontroller ZS Series Sensors The Aurora Unitary Protocol onverter (UP) is designed to add-on to any Aurora based heat pump control. The Aurora Unitary Protocol onvertor (UP) is designed to allow water source heat pumps to be integrated into Building Automation Systems (BAS) with ease. The Aurora UP is an integrated solution and communicates directly with the Aurora Heat Pump ontrols and allows access/control of a variety of internal Aurora heat pump operations such as sensors, relay operation, faults and other information. In turn, the UP then converts internal Aurora Modbus protocol to BAnet MS/TP, LON, or N2 protocols and communicates to the BAS system. This provides the great benefit of complete control integration and a myriad of information available to the BAS from the heat pump control. Plus it also allows individual unit configuration such as EM fan speeds or freeze protection setting directly over the BAS without the need for access to the actual heat pump. The Aurora UP is programmed using the powerful Eikon object oriented. The Aurora UP is implemented with the Aurora Base ontroller (AB) heat pump control into our latest water source heat pumps. This will allow for a BAS to integrate and communicate to the heat pump thru a choice of 3 different communication protocols. The Aurora UP has the ability to communicate BAnet MS/TP, N2 open, or LonWorks (requires LON Plugin card). This flexibility is possible due to the onboard dipswitches which allow for the desired protocol and baud rate to be selected in the field. All zone temperatures and zone sensors are connected to the UP on an Net bus, simplifying hook up at the unit. Net sensors can include a combination of zone temperature and humidity, O2, and VO sensors. The UP includes built-in support for a custom configurable keypad/display unit - BAview6 (4-line by 40 character per line display) or BAview5 (2-line by 16 character per line display). Up to 2 Keypad/display units can be mounted remotely for configuration and troubleshooting. There are an extensive number of points that the UP has available over the network for integration into the BAS. ontrol programmers need to carefully determine which points they want to add into the BAS database. A list of the BAnet points, N2 points, and LON SNVTs are available along with their individual point descriptions by contacting the ommercial Solutions roup at

21 ontrols - UP DD ontrol (optional) cont. N2 Modbus BAS BAnet LonWorks net Aurora UP Features ugged enclosure made of E 2950 ycoloy plastic Built-in surge transient protection circuitry Operating range of -20 to 140 F; 10 to 95% relative humidity, non-condensing Onboard 123A battery has a life of 10 years with 720 hours of cumulative power outage Multi-Protocol field selectable communication port that supports: EIA-485 BAnet 9600, 19.2k, 38.4k, 76.8k baud Metasys N2 Open LonWorks TP/FT-10 (equires optional LON plug-in communication card) Status of all unit operating conditions and fault lockouts Visual LED s for status of power, network communication, processor operation, and errors Provides gateway into Aurora heat pump controls for unsurpassed control flexibility Network point for commanding unit into load shed Network point for commanding unit into emergency shutdown Network points to assist in fan speed selection Network points for freeze protection settings Heating and cooling control from a remotely located zone sensor net communication port which allows for multiple net zone sensors (5) to be connected for space temperature averaging if desired. Local laptop or BAview connection for field service F, UL and E listed. BTL ertification is pending Aurora UP Optional Features BAview handheld display, needed for field configuration of fan speeds, set points, etc. AID Tool for Aurora AB configuration and troubleshooting. Aurora Advanced ontrol adds the Aurora AXB expansion board and provides added I/O and standard features Optional Sensor Kits (requires Aurora Advanced ontrol with AXB - Future Availability on Select Models/onfigurations) efrigeration Monitoring provides Suction and discharge pressure, Suction, liquid line temps and superheat and subcooling. Performance Monitoring provides entering and leaving loop water temperatures, loop flow rate as well as heat of extraction or rejection rate into the loop. Energy Monitoring provides real-time power measurement (Watt) of compressor, fan, auxiliary heat and zone pump. raphics packages available in the future 21

22 ontrols - UP DD ontrol (optional) cont. Port 1a is used to communicate to the Building Automation System (BAS). This port s settings are configured through the onboard dip switches. Port 2 is used to communicate to the Aurora Base ontroller (AB). Port 1b is used for the LonWorks plugin. 24Vac Dip switches for configuring the communication port protocol and baud rate for the BAS port. net port is used for communicating zone sensors. Mac address is set by 2 rotary dials. BAview or local laptop connection. Aurora Touch Interface Utilizing a touch-screen interface, the UP provides a technician the ability to configure and diagnose equipment at the unit or from any room sensor for added accessibility and simpler troubleshooting. The technician will have full access to equipment status, parameter values, temperature, and humidity sensing as well as access to alarm and trend history. With website-like navigation, the Aurora Touch Interface is easy to use and provides important insight into the system so your building can operate as efficiently as possible. Aurora UP Smart Tablet Option A smart tablet option is also available. Purchase a smart tablet accessory cable from WaterFurnace and download the OEMtrl App and connect to the unit either at the unit itself or via the zone sensor. This means connecting to the unit to adjust fan speeds, check on fault etc. as easily as walking up to the zone sensor without the need for accessing ceiling tiles or a stepladder. 22

23 ontrols - UP DD ontrol (optional) cont. 1. Leaving Air Temperature (LAT) Sensor This 10 kohm NT sensor is factory installed on all UP equipped heat pumps. It typically is attached to wiring inside the blower cabinet on the suction side of the blower. This sensor is attached on AB FP2 pins available as LAT AU ompressor Proving Sensors This optional factory installed current sensor is connected to confirm compressor operation via the power wires. The sensor is attached at AB Y1 and available at point BV Valve End Switch This optional input is setup for a field installed flow valve end switch. This end switch input is attached at AB Y2 and available at point BV Fan Proving Sensors This optional factory installed current sensor is connected to confirm fan operation via the power wires. The sensor is attached at AB and available at point BV Occupancy Sensor - This standard feature includes a field installed and wired room sensor with occupancy sensor typically found in DD systems. The Net room sensors can be found thru your commercial representative. The occupancy Sensors are attached at AB 0 and can be found at point BV Dirty Filter Switch This optional field installed switch is connected to confirm dirty filter operation. The dirty filter switch can be found thru your commercial representative. The sensor is attached at AB W and available at point BV Fault, onfiguration, and Status odes The codes can be visible to the BAS if desired Aurora Base Fault odes (AB Only) Fault LED (LED1, ed) ed Fault LED LED Flash ode* Lockout eset/ emove Normal - No Faults OFF Fault - Input 1 No Auto Fault - High Pressure 2 Yes Hard or Soft Fault - Low Pressure 3 Yes Hard or Soft Fault - Freeze Detection FP2 4 Yes Hard or Soft Fault - Freeze Detection FP1 5 Yes Hard or Soft Fault - ondensate Overflow 7 Yes Hard or Soft Fault - Over/Under Voltage 8 No Auto Fault - FP1 & FP2 Sensor Error 11 Yes Hard or Soft NOTE: All codes >11 use long flash for tens digit and short flash for the ones digit. 20, 30, 40, 50, etc. are skipped. AB Basic Faults Aurora Advanced Fault odes (AB + AXB Expansion Board) Fault LED (LED1, ed) AB Basic Faults ed Fault LED LED Flash ode * Lockout eset/ emove Fault ondition Summary Normal - No Faults Off - Fault-Input 1 No Auto Tstat input error. Autoreset upon condition removal. Fault-High Pressure 2 Yes Hard or Soft HP switch has tripped (>600 psi) Fault-Low Pressure 3 Yes Hard or Soft Low Pressure Switch has tripped (<40 psi for 30 continuous sec.) Fault-Freeze Detection FP2 4 Yes Hard or Soft Freeze protection sensor has tripped (<15 or 30 degf for 30 continuous sec.) Fault-Freeze Detection FP1 5 Yes Hard or Soft Freeze protection sensor has tripped (<15 or 30 degf for 30 continuous sec.) Fault-ondensate Overflow 7 Yes Hard or Soft ondensate switch has shown continuity for 30 continuous sec. Fault-Over/Under Voltage 8 No Auto Instantaneous voltage is out of range. **ontrols shut down until resolved. Fault-FP1 & 2 Snsr Error 11 Yes Hard or Soft If FP1 or 2 Sensor Error Fault-ompressor Monitor 10 Yes Hard or Soft Open rkt, un, Start or welded cont Non-riticAXBSnsrErr 13 No Auto Any Other Sensor Error riticaxbsnsrerr 14 Yes Hard or Soft Sensor Error for EEV or HW Alert-HotWtr 15 No Auto HW over limit or logic lockout. HW pump deactivated. Fault-VarSpdPump 16 No Auto Alert is read from PWM feedback. Not Used 17 No Auto IZ2 om Fault. Autoreset upon condition removal. Non-ritomErr 18 No Auto Any non-critical com error Fault-ritomErr 19 No Auto Any critical com error. Auto reset upon condition removal Alarm - Low Loop Pressure 21 No Auto Loop pressure is below 3 psi for more than 3 minutes Alarm - Home Automation 1 23 No Auto losed contact input is present on Dig 2 input - Text is configurable Alarm - Home Automation 2 24 No Auto losed contact input is present on Dig 3 input - Text is configurable NOTES: *All codes >11 use long flash for tens digit and short flash for the ones digit. 20, 30, 40, 50 etc. are skipped! Alert is a noncritical sensor or function that has failed. Normal operation of the heat pump is maintained but service is desired at some point. AB & AXB Advanced Faults 23

24 ontrols - UP DD ontrol (optional) cont. Aurora Base or Advanced ontrol onfiguration and Status odes Status LED (LED3, reen) Description of Operation Fault LED, reen Normal Mode ON ontrol is Non-functional OFF Test Mode Slow Flash Lockout Active Fast Flash Dehumidification Mode Flash ode 2 Load Shed Flash ode 5 Emergency Shutdown Flash ode 6 On Peak Mode Flash ode 7 (Future Use) Flash ode 8 (Future Use) Flach ode 9 onfiguration LED (LED2, Yellow) Description of Operation No Software Overwritten DIP Switch Overwritten EM onfiguration Mode eset onfiguration Mode onfiguration LED, Yellow EM Setting Slow Flash Fast Flash OFF 9. Alarm elay The Alarm relay (ALM) is factory connected to 24 VA via jumper JW2. By cutting JW2, AB ALM becomes a dry contact connected to AB AL. The elay is field switchable between Factory setting as an Alarm output or available for other uses. 10. Accessory elay1 A configurable, accessory relay on the AB is provided that can be cycled with the compressor, blower, or the Dehumidifier (DH) input. A third (factory) setting cycles the relay with the compressor but delays the compressor and blower output for 90 sec. Source pump or slow opening solenoid valves in well systems or variable speed primary pumping systems would be a prime use of this feature. Access elay Operation SW2-4 SW2-5 ycle with Blower ON ON ycle with ompressor OFF OFF Water Valve Slow Opening ON OFF ycle with omm. T-stat Hum md OFF ON 11. Electric Heat EH1 A digital 24VD output is provided for electric heat powering. UP s Default programming has EH1 set for AUX/ELE Heat operation and will be controlled using the UP s internal P.I.D. logic. However it can be changed by the BAS to be network controlled. 12. Electric Heat EH2 A digital VD output is provided for field options converted from the original EH2 output. Default UP program has the EH2 output set for Network ontrol but can be changed by the BAS to be controlled by the UP s internal P.I.D. logic. 24

25 ontrols - UP DD ontrol (optional) cont. Aurora Advanced ontrol onfiguration and Options (Future Availability on Select Models/onfigurations) 1. Accessory elay2 A second, configurable, accessory relay on the AXB is provided that can be cycled with the compressor 1 or 2, blower, or the Dehumidifier (DH) input. This is to complement the Accessory 1 elay on the AB board. Position DIP 4 DIP 5 Description 1 ON ON ycles with Fan or EM (or ) 2 OFF ON ycles with 1 first stage of compressor or compressor spd ON OFF ycles with 2 second stage of compressor or compressor spd OFF OFF ycles with DH input from AB board 2. Analog Out A standard 0-10VD analog output is provided. This output can be used to drive modulating dampers etc. 3. Variable Speed Pump or Modulating Water Valve (If applicable) - This input and output are provided to drive and monitor a variable speed pump. The VS pump output is a PWM signal to drive the variable speed pump. The minimum and maximum level are set using the AID Tool. 75% and 100% are the default settings respectively. The VS data input allows a separate PWM signal to return from the pump giving fault and performance information. Fault received from the variable speed pump will be displayed as E16. Modulating Water Valve - This Variable speed PWM output is provided to optionally drive a modulating water valve. Through advanced design a 0-10VD valve can be driven directly from the VS pump output. The minimum and maximum level are set in the same way as the VS pump using the AID Tool. 75% and 100% are the default settings respectively. 4. Loop Pump Slaving (If applicable) - This input and output are provided so that two units can be slaved together with a common flow center. When either unit has a call for loop pump, both unit s loop pump relays and variable speed pumps are energized. The flow center then can simply be wired to either unit. The output from one unit should be routed to the input of the other. If daisy chained up to 16 heat pumps can be wired and slaved together in this fashion. 25

26 ontrols - UP DD ontrol (optional) cont. Aurora Advanced ontrol Optional Sensor Kits (Availability on Select Models/onfigurations) 1. Energy Monitoring (Standard Sensor Kit on Advanced models) - The Energy Monitoring Kit includes two current transducers (blower and electric heat) added to the existing two compressor sensors so that the complete power usage of the heat pump can be measured. The BAview Tool provides configuration detail for the type of blower motor and a line voltage calibration procedure to improve the accuracy. This real time power usage information can be displayed on the AID Tool and is available thru network points when using BAnet or N2 Open. ompressor urrent 1 ompressor urrent 2 Fan urrent Aux Heat urrent Pump Selection Voltage ompressor Watts Fan Watts Aux Heat Watts Pump Watts (VS Only) 3. Performance Monitoring (optional sensor kit) - The optional Performance Monitoring Kit includes: three temperature sensors, entering and leaving water, leaving air temperature and a water flow rate sensor. With this kit, heat of extraction and rejection will be calculated. This requires configuration using the BAview Tool for selection of water or antifreeze. Leaving Air Temperature (supply) Alt Leaving Air Temperature (Supply) Entering Water Temperature Leaving Water Temperature Water Flow Meter Entering Air Temperature (from zone sensor) Brine Selection (water/antifreeze) Heat of Extraction/ejection 2. efrigerant Monitoring (optional sensor kit) - The optional efrigerant Monitoring Kit includes two pressure transducers, and three temperature sensors, heating liquid line, suction temperature and existing cooling liquid line (FP1). These sensors allow the measurement of discharge and suction pressures, suction and liquid line temperatures as well as superheat and subcooling. This information can be displayed on the BAview Tool, or the network when using BAnet and N2. Htg Liquid Line lg Liquid Line Discharge pressure Suction Pressure Discharge Saturated Temp Suction Saturated Temperature Superheat Subooling 26

27 ontrols - UP DD ontrol (optional) cont. ZS Series Net Sensor Overview The ZS Series line of intelligent zone sensors provides the function and flexibility you need to manage the conditions important to the comfort and productivity of the zone occupants. The ZS sensors are available in a variety of zone sensing combinations to address your application needs. These combinations include temperature, relative humidity, and indoor air quality (carbon dioxide or VOs (Volatile Organic ompounds)). They are built to be flexible allowing for easy customization of what the user/ technician sees. Designed to work with the Aurora UP controllers the ZS sensor line includes the ZS Base, ZS Plus, ZS Pro and ZS Pro-F. The UP uses a proprietary communication called net to receive the space temperature from the zone sensor. This is done using (2) 18 AW twisted pair unshielded cables for a total of 4 wires connected to the net port. The sensor gets its power from the UP controller and connecting multiple sensors to one UP will allow for space temperature averaging. The UP can support one ZS Pro or ZS Pro F with up to four ZS standard sensors wired to the net port on the UP for a total of 5 zone sensors. The sensors use a precise 10k ohm thermistor with less than 0.18 F drift over a ten year span, this allows for less maintenance or re-calibration after installation. The sensors also have a hidden communication port for connecting a BAview or local laptop that provides access to the equipment for commissioning and maintenance. The table below shows the features of each of the four sensors that are currently available. ZS Base ZS Pro-F ZS Plus ZS Pro Features ZS Base ZS Plus ZS Pro ZS Pro-F Temp, O 2, Humidity, and VO Options Neutral olor Addressable/supports daisy chaining Hidden communication port Mounts on a standard 2 by 4 electrical box Occupancy Status indicator LED Push button occupancy override Setpoint adjust Large, easy to read LD Alarm indicator F to conversion button Options Part Number Part Number Part Number Part Number Temperature Only ZSU ZSUPL ZSUP ZSUPF Temp with O 2 ZSU- ZSUPL- ZSUP- ZSUPF- Temp with Humidity ZSU-H ZSUPL-H ZSUP-H ZSUPF-H Temp with Humidity, O 2 ZSU-H ZSUPL-H ZSUP-H ZSUPF-H Temp, Humidity, VO ZSU-HV ZSUPL-HV ZSUP-HV ZSUPF-HV Temp with VO ZSU-V ZSUPL-V ZSUP-V ZSUPF-V 27

28 ontrols - UP DD ontrol (optional) cont. Net Sensor Physical and Electrical Data Sensing Element ange Accuracy Temperature (on non-humidity models) -4 to 122 F (-20 to 50 ) ±0.35 F (0.2 ) Temperature (on Humidity models) 50 F to 104 F (10 to 40 ) ±0.5 F (0.3 ) Humidity 10% to 90% ±1.8% typical O2 400 to 1250 PPM 1250 to 2000 PPM ±30PPM or +/-3% of reading (greater of two) ±5% of reading plus 30 PPM VO 0 to 2,000 PPM ±100 PPM Power equirements Sensor Type Power equired Temperature Only All Models 12 8 ma Temperature with Humidity All Models ma (idle) to 190 ma (O2 measurement cycle) Temp with VO, or Temp/VO/Humidity All Models ma Temp with O2, or Temp/ O2/Humidity All Models ma (idle) to 190 ma (O2 measurement cycle) Power Supply ommunication Local Access Port Environmental Operating ange Mounting Dimensions A controller supplies the net sensor network with ma. Additional power may be required for your application. See sensor ZS Installation uide 115 kbps net connection between sensor(s) and controller 15 sensors max per net network; 5 sensors max per control program For connecting a laptop computer to the local equipment for maintenance and commissioning 32 to 122 F (0-50 ), 10% to 90% relative humidity, non-condensing Standard 4 x 2 electrical box using provided 6/32 x 1/2 mounting screws D mmm (same for all) W mm (same for all) H mmm (same for all) (with optional motion sensor) D mm 28

29 Application Notes The losed Loop Heat Pump oncept The basic principle of a water source heat pump is the transfer of heat into water from the space during cooling, or the transfer of heat from water into the space during heating. Extremely high levels of energy efficiency are achieved as electricity is used only to move heat, not to produce it. Using a typical WaterFurnace Versatec ompact Series, one unit of electricity will move four to five units of heat. When multiple water source heat pumps are combined on a common circulating loop, the ultimate in energy efficiency is created: The WaterFurnace units on cooling mode are adding heat to the loop which the units in heating mode can absorb, thus removing heat from the area where cooling is needed, recovering and redistributing that heat for possible utilization elsewhere in the system. In modern commercial structures, this characteristic of heat recovery from core area heat generated by lighting, office equipment, computers, solar radiation, people or other sources, is an important factor in the high efficiency and low operating costs of WaterFurnace closed source heat pump systems. eturn Water low because units can be added to the loop on an as needed basis - perfect for speculative buildings. Installed costs are low since units are self-contained and can be located adjacent to the occupied space, requiring minimal ductwork. Maintenance can be done on individual units without system shut-down. onditions remain comfortable since each unit operates separately, allowing cooling in one area and heating in another. Tenant spaces can be finished and added as needed. Power billing to tenants is also convenient since each unit can be individually metered: each pays for what each uses. Nighttime and/or weekend uses of certain areas are possible without heating or cooling the entire facility. A decentralized system also means if one unit should fault, the rest of the system will continue to operate normally, as well as eliminating air cross-contamination problems and expensive high pressure duct systems requiring an inefficient electric resistance reheat mode. The Versatec ompact Approach There are a number of proven choices in the type of Versatec ompact Series system which would be best for any given application. Most often considered are: Vertical - losed Loop/round Source Versatec Unit Versatec Unit Heater/ ejector Versatec Unit Versatec Unit Versatec Unit Versatec Unit Pumps Supply Water In the event that a building's net heating and cooling requirements create loop temperature extremes, Versatec ompact Series units have the extended range capacity and versatility to maintain a comfortable environment for all building areas. Excess heat can be stored for later utilization or be added or removed in one of three ways; by ground-source heat exchanger loops: plate heat exchangers connected to other water sources, or conventional cooler/ boiler configurations. Your WaterFurnace representative has the expertise and computer software to assist in determining optimum system type for specific applications. The losed Loop Advantage A properly applied water source heat pump system offers many advantages over other systems. First costs are losed Loop/round-Source Systems utilize the stable temperatures of the earth to maintain proper water source temperatures (via vertical or horizontal closed loop heat exchangers) for Versatec ompact Series extended range heat pump system. Sizes range from a single unit through many hundreds of units. When net cooling requirements cause closed loop water temperatures to rise, heat is dissipated into the cooler earth through buried high strength plastic pipe heat exchangers. onversely if net space heating demands cause loop heat absorption beyond that heat recovered from building core areas, the loop temperature will fall causing heat to be extracted from the earth. Due to the extended loop temperatures, AHI/ ISO round Loop Heat Pumps are required for this application. Because auxiliary equipment such as a fossil 29

30 Application Notes cont. fuel boiler and cooling tower are not required to maintain the loop temperature, operating and maintenance costs are very low. Plate Heat Exchanger - losed Loop/round Water round-source systems are most applicable in residential and light commercial buildings where both heating and cooling are desired, and on larger envelope dominated structures where core heat recovery will not meet overall heating loads. Both vertical and horizontally installed closed-loops can be used. The land space required for the heat exchangers is sq. ft./ton on vertical (drilled) installations and sq. ft./ton for horizontal (trenched) installations. losed loop heat exchangers can be located under parking areas or even under the building itself. On large multi-unit systems, sizing the closed loop heat exchanger to meet only the net heating loads and assisting cooling loads with a closed circuit cooling tower may be the most cost effective choice. Surface Water - losed Loop/round Source losed Loop/round Water Plate Heat Exchanger Systems utilize lake, ocean, well water or other water sources to maintain closed loop water temperatures in multi-unit Versatec ompact systems. A plate frame heal exchanger isolates the units from any contaminating effects of the water source, and allows periodic cleaning of the heat exchanger during off peak hours. Operation and benefits are similar to those for groundsource systems. Due to the extended loop temperatures, AHI/ISO round Loop Heat Pumps are required for this application. losed loop plate heat exchanger systems are applicable in commercial, marine, or industrial structures where the many benefits of a water source heat pump system are desired, regardless of whether the load is heating or cooling dominated. losed Loop/round-Source Surface Water Systems also utilize the stable temperatures of Surface Water to maintain proper water source temperatures for Versatec ompact Series extended range heat pump systems. These systems have all of the advantages of horizontal and vertical closed loop systems. Due to the extended loop temperatures, AHI/ISO round Water or round Loop Heat Pumps are required for this application. In cooling dominated structures, the ground-source surface water systems can be very cost effective especially where local building codes require water retention ponds for short term storage of surface run-off. Sizing requirements for the surface water is a minimum of 500 sq. ft./ton of surface area at a minimum depth of 8 feet. WaterFurnace should be contacted when designs for heating dominated structures are required. 30

31 Application Notes cont. ooler/boiler - losed Loop losed Loop /ooler-boiler Systems utilize a closed heat recovering loop with multiple water source heat pumps in the more conventional manner. Typically a boiler is employed to maintain closed loop temperatures above 60 F and a cooling tower to maintain loop temperatures below 90 F. These systems are applicable in medium to large buildings regardless of whether the load is heating or cooling dominated. Due to the moderate loop temperatures, AHI/ISO Water Loop Heat Pumps are required for this application. 31

32 Water Quality It is the responsibility of the system designer and installing contractor to ensure that acceptable water quality is present and that all applicable codes have been met in these installations. Failure to adhere to the guidelines in the water quality table could result in loss of warranty. In ground water situations where scaling could be heavy or where biological growth such as iron bacteria will be present, a closed loop system is recommended. The heat exchanger coils in ground water systems may, over a period of time, lose heat exchange capabilities due to a buildup of mineral deposits inside. These can be cleaned, but only by a qualified service mechanic, as special solutions and pumping equipment are required. Hot water generator coils can likewise become scaled and possibly plugged. In areas with extremely hard water, the owner should be informed that the heat exchanger may require occasional flushing. Units with cupronickel heat exchangers are recommended for open loop applications due to the increased resistance to build-up and corrosion, along with reduced wear caused by acid cleaning. Failure to adhere to the guidelines in the water quality table could result in the loss of warranty. Water Treatment Do not use untreated or improperly treated water. Equipment damage may occur. The use of improperly treated or untreated water in this equipment may result in scaling, erosion, corrosion, algae or slime. Purchase of a pre-mix antifreeze could significantly improve system reliability if the water quality is controlled and there are additives in the mixture to inhibit corrosion. There are many examples of such fluids on the market today such as Environol 1000 (pre-mix ethanol), and others. The services of a qualified water treatment specialist should be engaged to determine what treatment, if any, is required. The product warranty specifically excludes liability for corrosion, erosion or deterioration of equipment. The heat exchangers and water lines in the units are copper or cupronickel tube. There may be other materials in the buildings piping system that the designer may need to take into consideration when deciding the parameters of the water quality. If antifreeze or water treatment solution is to be used, the designer should confirm it does not have a detrimental effect on the materials in the system. ontaminated Water In applications where the water quality cannot be held to prescribed limits, the use of a secondary or intermediate heat exchanger is recommended to separate the unit from the contaminated water. The table above outlines the water quality guidelines for unit heat exchangers. If these conditions are exceeded, a secondary heat exchanger is required. Failure to supply a secondary heat exchanger where needed will result in a warranty exclusion for primary heat exchanger corrosion or failure. Material opper 90/10 upronickel 316 Stainless Steel ph Acidity/Alkalinity Scaling alcium and (Total Hardness) (Total Hardness) (Total Hardness) Magnesium arbonate less than 350 ppm less than 350 ppm less than 350 ppm Hydrogen Sulfide Less than 0.5 ppm (rotten egg smell appears at 0.5 ppm) ppm Less than 1 ppm Sulfates Less than 125 ppm Less than 125 ppm Less than 200 ppm hlorine Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm hlorides Less than 20 ppm Less than 125 ppm Less than 300 ppm arbon Dioxide Less than 50 ppm ppm ppm orrosion Ammonia Less than 2 ppm Less than 2 ppm Less than 20 ppm Ammonia hloride Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Nitrate Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Hydroxide Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Sulfate Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Total Dissolved Solids (TDS) Less than 1000 ppm ppm ppm LSI Index +0.5 to to to -0.5 Iron, FE 2 + (Ferrous) Iron Fouling Bacterial Iron Potential < 0.2 ppm < 0.2 ppm < 0.2 ppm (Biological rowth) Less than 1 ppm, above this Less than 1 ppm, above this Less than 1 ppm, above this Iron Oxide level deposition will occur level deposition will occur level deposition will occur Suspended Solids Erosion Threshold Velocity (Fresh Water) NOTES: rains = ppm divided by 17 mg/l is equivalent to ppm Less than 10 ppm and filtered for max. of 600 micron size Less than 10 ppm and filtered for max. of 600 micron size Less than 10 ppm and filtered for max. of 600 micron size < 6 ft/sec < 6 ft/sec < 6 ft/sec 2/22/12 32

33 Installation Notes Typical Unit Installation Unit Location Locate the unit in an indoor area that allows for easy removal of the filter and access panels. Location should have enough space for service personnel to perform maintenance or repair. Provide sufficient room to make water, electrical and duct connection(s). If the unit is located in a confined space, such as a closet, provisions must be made for return air to freely enter the space by means of a louvered door, etc. Any access panel screws that would be difficult to remove after the unit is installed should be removed prior to setting the unit. On horizontal units, allow adequate room below the unit for a condensate drain trap and do not locate the unit above supply piping. are should be taken when units are located in unconditioned spaces to prevent damage from frozen water lines and excessive heat that could damage electrical components. Water Piping Piping is usually design as reverse return to equalize flow paths through each unit. A short flexible pressure rated hose is used to make connection to the fixed building piping system. This hose is typically stainless steel braid and includes a swivel fitting on one end for easy removal and is flexible to help isolate the unit for quieter operation. Isolation valves for servicing, y-strainers for filtering and memory-stop flow valve or a balancing valve can be provided for consistent water flow through the unit. All unit source water connections are fittings that accept a male pipe thread (MPT). Insert the connectors by hand, then tighten the fitting with a wrench to provide a leakproof joint. The open and closed loop piping system should include pressure/temperature ports for serviceability. The proper water flow must be provided to each unit whenever the unit operates. To assure proper flow, use pressure/ temperature ports to determine the flow rate. These ports should be located at the supply and return water connections on the unit. The proper flow rate cannot be accurately set without measuring the water pressure drop through the refrigerant-to-water heat exchanger. Never use flexible hoses smaller than the inside diameter of the water connection at the unit. Limit hose length to 10 feet per connection. heck carefully for water leaks. 33

34 Installation Notes cont. Installing Horizontal Units emove and discard the compressor hold down shipping bolt or screw located at the front or side (side, horizontal only) of the compressor mounting bracket prior to setting the unit in place. Horizontal units are available with side or end discharge. NOTE: Left (ight) eturn Side Discharge cannot be converted to Left (ight) eturn End Discharge or vice versa, without additional custom sheet metal parts. Horizontal units are normally suspended from a ceiling by four 3/8 in. diameter threaded rods. The rods are usually attached to the unit by hanger bracket kits furnished with each unit. Lay out the threaded rods per the Hanger Bracket Dimensions table. Assemble the hangers to the unit as shown. Securely tighten the brackets to the unit using the weld nuts located on the underside of the bottom panel. When attaching the hanger rods to the bracket, a double nut is required since vibration could loosen a single nut. To allow filter access, install hanger brackets as illustrated in the Hanger Bracket Locations section. The unit should be pitched approximately 1/4 in. towards the drain in both directions to facilitate the removal of condensate. Use only the bolts provided in the kit to attach hanger brackets. The use of longer bolts could damage internal parts. Some applications require the installation of horizontal units on an attic floor. In this case, the unit should be set in a full size secondary drain pan on top of a vibration absorbing pad. The secondary drain pan prevents possible condensate overflow or water leakage damage to the ceiling. The secondary drain pan is usually placed on a plywood base isolated from the ceiling joists by additional layers of vibration absorbing material. AUTION: Do not use rods smaller than 3/8 in. diameter since they may not be strong enough to support the unit. The rods must be securely anchored to the ceiling. 34

35 Installation Notes cont. Acoustical onsiderations and Equipment Sound Performance Sound Performance The Versatec ompact Series is third party sound rated in accordance with AI 260. Please consult WaterFurnace Sound Performance Data atalog for details on the AHI standard and sound performance data. ecommendations for Noise eduction Horizontal Unit Location Specify equipment with quietest sound power ratings Do not locate units above areas with a required N 40 or less Space WSHP at least 10 ft (3m) apart to avoid noise summing of multiple units in a space. Maximize the height of the unit above the ceiling (horizontal). Suspend unit with isolation grommets that are appropriately rated to reduce vibrations (horizontal). Vertical Unit Location Specify equipment with quietest sound power ratings Space WSHP at least 10 ft (3m) apart to avoid noise summing of multiple units in a space. Acoustic ceiling coatings can greatly reduce noise levels in mechanical rooms. Mount unit on a sound absorbing pad, extruded polystyrene, rubber or cork pad. Ductwork Ensure return air grilles will not allow line of site noise to transfer to adjacent space. Use a sound barrier or some other material to isolate the grille from the unit. A supply grille, boot and short piece of flex duct pointed away from the unit can greatly attenuate equipment noise. Use a canvas isolation duct connector at the supply and return duct connection of the unit. Internally line the discharge and return duct within the first 4-8 feet of unit with acoustic insulation. Install an internally lined L shaped return duct elbow at return grille. Face the elbow away from adjacent units. Always install at least one 90 elbow in the discharge duct to eliminate line of sight noise transmission of the blower. Use turning vanes at all elbows and tees to reduce turbulence. Limit supply duct velocities to less than 1,000 fpm Design and install ductwork as stiff as possible Allow 3 duct diameters both up and down stream of the unit before any fittings or transitions are installed. Use duct sealant on all duct joints. Install a short (2-4 ) of flex duct on all branch ducts just prior to discharge boot or diffuser to reduce vibration and duct sound prior to delivery in the room. Locate the branch duct balancing damper as far away from the diffuser as possible. In ceiling plenum systems, install an internally lined L shaped return duct elbow at unit. Face the elbow away from adjacent units (horizontal). 35

36 Vertical Dimensional Data Standard filter rails for open return applications Field installed duct flange Deluxe filter rack for ductable return applications A N S A N Air coil Q Q AESS PANEL B P F FONT Top View - ight eturn AI OIL SIDE M M AI OIL SIDE FONT 2' (61 cm) Alternate Service Access Top View - Left eturn 2' (61 cm) Service Access Left eturn (ight eturn Opposite Side) P F B Isometric View - Left eturn U T W Air coil Air coil AESS PANEL AESS PANEL V H E D 1.6 in (4.1 cm) ondensate 3/4 in PV glue socket 1.6 in (4.1 cm) Water 1 onnections* L J Power supply 1 in (25.4 mm) knockout Low voltage 1/2" (12.7 mm) knockout L K ondensate 3/4 in PV glue socket 1.6 in (4.1 cm) 8 7 Water onnections* E H D 1.6 in (4.1 cm) J L 6 8 AESS PANEL 8 7 K L Front View - ight eturn Front View - Left eturn ight View - ight eturn (J & L) Left View - Left eturn (K & L) NOTE: * Water connections protrude approximately 1.5 in. (3.81cm) from cabinet. 36

37 Vertical Dimensional Data cont. Vertical Models Vertical Models Overall abinet Water onnections Electrical Knockouts J K L A B D E H Loop 1/2 cond 1/2 cond 1 cond M Width Depth Height* In Out ondensate Water FPT Low Low Power Supply Width Filter ack Voltage Voltage in / cm mm in / cm mm in / cm mm in / cm mm in / cm mm in / cm mm in cm mm in cm mm Discharge onnection duct flange installed (±0.10 in) **eturn onnection using deluxe filter rack (±0.10 in) N P Q S T U V W Supply Width Supply Depth eturn Depth eturn Height in cm in cm in cm in cm in cm in cm in cm in cm ondensate is 3/4 PV female glue socket and is switchable from side to front. 10/15/15 *Discharge flange is field installed and extends 1 (25.4 mm) from top of cabinet. **Vertical units shipped with standard 2 (field adjustable to 1 ) open application filter rack extending 2.2 from unit and is not suitable for duct connection. For ductable return connection applications, order the deluxe 2 (field adjustable to 1 ) duct collar/filter rack which extends 3.25 Vertical Disconnect When using disconnect, do not use dimension L from the standard vertical dimensional data. Use dimension LL from the vertical disconnect dimensional data. Vertical Models LL [40.1] [47.8] [38.9] [35.1] [36.3] [36.3] Dimensions in inches [cm] * Models Externally Mounted Disconnect **UBV Disconnect not available Power Supply 1.8 in. [4.6 cm] Disconnect Location LL Alternative Power Location Disconnect Located on this Side for a ight eturn Vertical Shown in Left eturn onfiguration 37

38 Horizontal Dimensional Data ight eturn Standard filter rails 1 in knockout 1/2 in knockout Front K P AP Standard filter rails Front Left eturn J MP E AP MP A ight eturn Air Front View D AP MP ondensate "X" PV size End Discharge Side Discharge 2' (61 cm) Service Access E 2 1 P AP MP 1/2 in knockout 1 in knockout Side Discharge ondensate "X" PV size End Discharge Deluxe filter rack option shown D Left eturn Air Front View Deluxe filter rack option shown 2.3 N P P N 2.3 J K 2' (61 cm) Service Access H FILTE AK AI OIL SIDE BLOWE L OUTLET Legend M AP = Alternate Service Panel M 3 L BP P = Blower Service Panel = ontrol Access Panel BLOWE OUTLET BP MP = ompressor Service Panel A BP A 2.1 ight eturn End Discharge Left eturn End Discharge FILTE AK AI OIL SIDE H P N N P BP L M BLOWE OUTLET AP MP K 1/2 in knockout J 1 in knockout Front Front 1" knockout J 1/2 in knockout K AP MP BLOWE OUTLET M L BP ight eturn Side Discharge Left eturn Side Discharge Front Air oil Q S T T S Q FILTE AK ONNETION Deluxe filter rack option (shown) FILTE AK ONNETION Air oil Front Water onnections* B ight eturn Side View B Left eturn Side View Water onnections* NOTE: * Water connections protrude approximately 1.5 in. from cabinet. 38

39 Horizontal Dimensional Data cont. Horizontal Models ** Horizontal Models Water onnections Electrical Knockouts Overall abinet J K Loop A B D E H 1/2 in. cond 1 in. cond Width Depth Height* In Out ondensate Water FPT Low Voltage Power Supply in /2 in cm mm in /4 in cm mm in /4 in cm mm in /4 in cm mm in /4 in cm mm in in cm mm in in cm mm Discharge onnection duct flange installed (±0.10 in) eturn onnection using deluxe filter rack option (±0.10 in) L M N P Q S T X Supply Width Supply Depth eturn Depth eturn Height PV Size ** in /2 in. cm in /4 in. cm in /4 in. cm in /4 in. cm in /4 in. cm in /4 in. cm in /4 in. cm Horizontal units shipped with standard 2 in. (field adjustable to 1 in.) open application filter rail extending 2.2 in. from the unit and 09/26/12 is not suitable for duct connection. For ductable return connection applications, order the 2 in. (field adjustable to 1 in.) duct collar/ filter rack which extends to 3.25 in. from the unit and is suitable for duct connections. ** UBH offers a lifted drain pan that allows the trap to be installed without additional ceiling height required. Horizontal Disconnect When using disconnect, do not use dimension K from the standard horizontal dimensional data. Use dimension KK from the horizontal disconnect dimensional data. Horizontal Models KK [20.8] [20.8] [23.4] [23.4] [28.4] [25.9] Dimensions in inches [cm] * Models Externally Mounted Disconnect Disconnect Located on this Side for a Left eturn 2.1 in. [5.3 cm] Disconnect Location KK Power Supply Horizontal Shown in ight eturn onfiguration 39

40 Hanger Bracket Locations ight Left B D E ompressor Section Air Handler Section F E D ompressor Section Air Handler Section F A 3/8 Threaded od (not supplied) Vibration Isolator Washer Bolt and Lockwasher Hex Nuts (not supplied) Hanger Dimensions Model Hanger Kit Part Number Unit Hanger Dimensions A B in. 99S500A04 cm in S500A04 cm in S500A04 cm in S500A04 cm in S500A04 cm in S500A04 cm in S500A04 cm /26/12 Weight Distribution Model Vertical Shipping Weight Horizontal Shipping Weight Horizontal Weight Distribution Front Back D E F lbs kg lbs kg lbs kg lbs kg lbs kg lbs 243 kg 110 N/A lbs kg lbs kg lbs kg lbs kg /15/

41 Physical Data Model Single Speed Models ompressor (1 each) otary Scroll Factory harge 410A, oz [kg] 24 [0.68] 26 [0.74] 26 [0.74] 30 [0.85] 34 [0.96] * * * * * * * * Vertical Factory harge 410A, oz [kg] 24 [0.68] 24 [0.68] 26 [0.74] 30 [0.85] 34 [0.96] * * * * * * * * Horizontal Blower Motor & Blower VS EM Variable Speed (onstant Torque) Variable Speed (onstant FM) Blower Motor Type/Speeds 5 Speed EM Not Available 5 Speed PS 4 Speeds 3 Speed VS EM 1/10 [75] 1/10 [75] 1/10 [75] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] Blower Motorhp [W] 5 Speed EM Not Available 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] 1 [746] 1 [746] PS 1/10 [75] 1/10 [75] 1/10 [75] 1/6 [134] 1/6 [134] 1/5 [149] 1/3 [249] 1/2 [373] 1/3 [249] 1/2 [373] 1/2 [373] 1 [746] 1 [746] VS EM 6 x 8 [152 x 203] 6 x 8 [152 x 203] 6 x 8 [152 x 203] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 11 x x 10 [279 x 254] [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] Blower Wheel Size (Dia x W), in. [mm] 5 Speed EM Not Available 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 11 x x 10 [279 x 254] [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] PS 6 x 8 [152 x 203] 6 x 8 [152 x 203] 6 x 8 [152 x 203] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 10 x x 10 [254 x 254] [254 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] oax and Water Piping Water onnection Size - FPT - in [mm] oax & Piping Water Volume - gal [l] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 1 [25.4] 1 [25.4] 0.4 [1.49] 0.4 [1.49] 0.4 [1.49] 0.4 [1.49] 0.4 [1.49] 0.4 [1.49] 0.75 [2.83] 0.9 [3.41] 0.9 [3.41] 0.9 [3.41] 1.25 [4.72] 1.5 [5.68] 1.5 [5.68] Vertical Air oil Dimensions (H x W), in. [mm] Air oil Total Face Area, ft2 [m2] Air oil Tube Size, in [mm] 12 x x x x x x x x x 16 [305 x 356] [305 x 356] [305 x 356] [406 x 406] [406 x 406] [559 x 406] [559 x 406] [610 x 508] [660 x 406] 28 x 20 [711 x 508] 28 x 20 [711 x 508] 28 x 25 [711 x 635] 32 x 25 [813 x 635] 1.17 [0.11] 1.17 [0.11] 1.17 [0.11] 1.8 [0.17] 1.8 [0.17] 2.4 [0.2] 2.4 [0.2] 3.3 [0.307] 2.9 [0.269] 3.9 [0.362] 3.9 [0.362] 4.9 [0.455] 5.6 [0.520] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air oil Number of rows Filter Standard - 1 [25mm] MEV4 Throwaway, in [mm] 12 x x x x x x x 20 [305 x 406] [305 x 406] [305 x 406] [406 x 508] [406 x 508] [559 x 508] [559 x 508] 24 x 24 [610 x 610] 28 x 20 [711 x 508] 28 x 24 [711 x 610] 28 x 24 [711 x 610] 28 x 30 [711 x 762] 32x 30 [813 x 762] Filter Standard - 2 [51mm] Pleated MEV13 Throwaway, in [mm] 12 x x x x x x x x 24 [305 x 406] [305 x 406] [305 x 406] [406 x 508] [406 x 508] [559 x 508] [559 x 508] [610 x 610] N/A 28 x 24 [711 x 610] 28 x 24 [711 x 610] 28 x 30 [711 x 762] 32x 30 [813 x 762] Horizontal Air oil Dimensions (H x W), in. [mm] 8 x 22 8 x 22 8 x x x x x x 27 [203 x 559] [203 x 559] [203 x 559] [406 x 406] [406 x 406] [406 x 584] [406 x 584] [457 x 686] 18 x x x x 40 [457 x 762] [457 x 762] [508 x 889] [508 x 1016] Air oil Total Face Area, ft2 [m2] Air oil Tube Size, in [mm] 1.22 [0.11] 1.22 [0.11] 1.22 [0.11] 1.8 [0.17] 1.8 [0.17] 2.6 [0.238] 2.6 [0.238] 2.9 [0.269] 3.8 [0.353] 3.8 [0.353] 4.9 [0.455] 5.6 [0.52] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air oil Number of rows N/A Filter Standard - 1 [25mm] MEV 4 Throwaway, in [mm] 11 x x x x x x x x 14 [279 x 635] [279 x 635] [279 x 635] [406 x 508] [406 x 508] [406 x 635] [406 x 635] [457 x 356] 1-18 x 18 [457 x 457] 1-18 x 14 [457 x 356] 1-18 x 18 [457 x 457] 1-18 x 14 [457 x 356] 2-18 x 20 [457 x 508] 1-20 x 22 [508 x 559] 1-20 x 20 [508 x 508] Filter Standard - 2 [51mm] Pleated MEV 13 Throwaway, in [mm] 11 x x x x x x x x 29 [279 x 635] [279 x 635] [279 x 635] [406 x 508] [406 x 508] [406 x 635] [406 x 635] [457 x 737] 18 x x x x 22 [508 x 559] [457 x 813] [457 x 813] [508 x 940] 1-20 x 20 [508 x 508] * Not available at the time of publishing release 8/1/18 41

42 Electrical Availability PS Single Speed Models Voltage /60/ /60/1 265/60/ /60/3 460/60/3 575/60/3 10/15/15 Variable Speed EM Single Speed Models Voltage /60/ /60/1 265/60/ /60/3 460/60/3 575/60/3 3/18/18 5 Speed EM Single Speed Models Voltage /60/1 265/60/ /60/3 460/60/3 575/60/3 12/19/17 42

43 Electrical Data PS Motor Model ated Voltage Voltage Min/Max ompressor M LA LA Blower Motor FLA Total Unit FLA Min irc Amp Max Fuse/ HA Breaker 115/60/1 104/ /60/1 187/ /15 265/60/1 238/ /15 115/60/1 104/ /60/1 187/ /15 265/60/1 238/ /15 115/60/1 104/ /60/1 187/ /15 265/60/1 238/ / /60/1 187/ /60/1 238/ / /60/1 187/ /60/1 238/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ HA circuit breaker in USA only 8/1/18 43

44 Electrical Data cont. 5 Speed EM Motor Model ated Voltage Voltage Min/ Max ompressor M LA LA Blower Motor FLA Total Unit FLA Min irc Amp Max Fuse/ HA Breaker /60/1 187/ /60/1 238/ / /60/1 187/ /60/1 238/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ HA circuit breaker in USA only 8/1/18 44

45 Electrical Data cont. Variable Speed EM Motor Model ated Voltage Voltage Min/Max ompressor M LA LA Blower Motor FLA Total Unit FLA Min irc Amp Max Fuse/ HA Breaker /60/1 104/ /60/1 187/ / /60/1 104/ /60/1 187/ / /60/1 104/ /60/1 187/ / /60/1 187/ /60/1 238/ /60/1 187/ /60/1 238/ /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ / /60/1 187/ /60/1 238/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ HA circuit breaker in USA only 8/1/18 aution: When installing a unit with a Variable Speed EM blower motor in 460/60/3 voltage, a neutral wire is required to allow proper unit operation. 45

46 Blower Performance Data Standard PS Motor Model Blower Blower Motor Airflow (cfm) at External Static Pressure (in. wg) Spd Size HP H MH x 8 1/10 ML* L H MH x 8 1/10 ML* L H MH x 8 1/10 ML* L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 10x10 1/ L H M 10 x 10 1/ L H M 11 x L H M 11 x L Factory settings are in Bold 10/15/15 Airflow values are with dry coil and standard filter For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]). Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12 in. wg. and 500 fpm by 0.16 in. wg. * Setting for 265V operation. 46

47 Blower Performance Data cont. 5- Speed EM Motor Model Motor Spd Motor Tap Blower Size Motor HP Airflow (cfm) at External Static Pressure (in. wg) High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 9 x 7 1/ Med Low Low High Med High Med 3 11 x Med Low Low High Med High Med 3 11 x Med Low Low High Med High Med 3 11 x Med Low Low High Med High Med 3 11 x Med Low Low Factory settings are in Bold 10/15/15 Air flow values are with dry coil and standard 1 filter 5-Speed EM Motor onnections - Black L - Orange - reen High Voltage onnections 3/16 in. L N N - Brown - Blue Y1 - ed Low Voltage onnections 1/4 in. AUX - ray 47

48 Blower Performance Data cont. Variable Speed onstant Torque EM Fan Speed Fan Airflow [cfm] at External Static Pressure [in. wg.] PM /18/2018 Variable Speed EM Motor Model Max Blower Motor Air Flow Dip Switch Settings ESP Size hp x 7 1/ L M H x 7 1/ L M H x 7 1/ L M H x 7 1/ L M H x 7 1/ L M H x 7 1/ L M H x 10 1/ L M H x 10 1/ L M H x L M H x L M H Factory settings are at recommended L-M-H DIP switch locations 10/15/15 FM is controlled within ±5% up to the maximum ESP M-H settings MUST be located within boldface FM range Max ESP includes allowance for wet coil and standard filter Lowest and Highest DIP switch settings are assumed to be L and H respectively 48

49 Blower Performance Data cont. Setting Blower Speed - Variable Speed EM The AB board s Yellow onfig LED will flash the current variable speed EM blower speed selections for low, med, and high continuously with a short pause in between. The speeds can also be confirmed with the AID Tool under the Setup/EM Setup screen. The variable speed EM blower motor speeds can be field adjusted with or without using an AID Tool. Variable Speed EM Setup with an AID Tool cont. EM SPEED INFO LOW SPEED: 3 MED SPEED: 5 HIH SPEED: 7 Selecting YES will enter variable speed EM speed setup, while selecting NO will return to the previous screen. Variable Speed EM Setup without an AID Tool The blower speeds for Low ( only), Med (Y1), and High (Y2/Aux) can be adjusted directly at the Aurora AB board which utilizes the push button (SW1) on the AB board. This procedure is outlined in the Variable Speed EM onfiguration Mode portion of the Aurora Base ontrol System section. Variable Speed EM Setup with an AID Tool A much easier method utilizes the AID Tool to change the airflow using the procedure below. First navigate to the Setup screen and then select EM Setup. This screen displays the current variable speed EM settings. It allows the technician to enter the setup screens to change the variable speed EM settings. hange the highlighted item using the and buttons and then press the button to select the item. WANT TO HANE? YES OPTION NO ENTE Variable Speed EM Speed Setup - These screens allow the technician to select the low, medium, and high blower speed for the variable speed EM blower motor. hange the highlighted item using the and buttons. Press the button to select the speed. EM SPEED INFO 1 2 < LOW EM SPEED INFO 1 2 LOW < MED EM SPEED INFO 1 2 LOW MED < HIH OPTION ENTE OPTION ENTE OPTION ENTE After the high speed setting is selected the AID Tool will automatically transfer back to the EM Setup screen. 49

50 Selection Example To achieve optimal performance, proper selection of each heat pump is essential. A building load program should be used to determine the heating and cooling load of each zone. A computer software selection program can then be used to develop an accurate and complete heat pump schedule. Software can be obtained from your local WaterFurnace representative. While a computer software program is the easiest and most accurate method to size and select equipment, however, selection can still be accomplished manually using this manual and the following selection procedure. Sizing so that the actual sensible capacity of the equipment will satisfy the sensible capacity of the zone is the recommended method for best results. Boiler/Tower Application Typical boiler/tower application will result in entering water temperatures of F with 70 F for heating and 90 F for cooling. Water to refrigerant insulation option would not be required. Flow rates are 2.5 to 3 gpm per ton with 2.5 gpm per ton often representing an economical design point. eothermal Application Typical geothermal application can result in a wide entering water temperature range of F. Typically minimum heating entering water temperatures can range from 30 to 50 F depending upon loop type and geographical location. ooling performance should be calculated using a maximum loop temperature of 100 F in most loop applications. Water flow is typically 2.5 to 3 gpm per ton with 3 gpm per ton recommended with the more extreme loop temperatures. PLEASE NOTE THAT WATE OIL INSULATION OPTION SHOULD BE SELETED WHEN ENTEIN WATE TEMPEATUES AE EXPETED TO BE BELOW F. eothermal Selection Example Step 1: Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2: Obtain the following design parameters: Entering water temperature, water flow rate in gpm, airflow in cfm, water flow pressure drop and design wet and dry bulb temperatures. Airflow, cfm, should be between 300 and 450 cfm per ton. Unit water pressure drop should be kept as close as possible to each other to make water balancing easier. o to the appropriate tables and find the proper indicated water flow and water temperature. Step 4: Enter tables at the design water flow and water temperature. ead the total and sensible cooling capacities (NOTE: interpolation is permissible, extrapolation is not). Step 5: ead the heating capacity. If it exceeds the design criteria it is acceptable. It is quite normal for water source heat pumps to be selected on cooling capacity only since the heating output is usually greater than the cooling capacity. Step 6: Determine the correction factors associated with the variable factors of dry bulb and wet bulb. orrected Total ooling = tabulated total cooling x wet bulb correction. orrected Sensible ooling = tabulated sensible cooling x wet/dry bulb correction. Step 7: ompare the corrected capacities to the load requirements. Normally if the capacities are within 10% of the loads, the equipment is acceptable. It is better to undersize than oversize, as undersizing improves humidity control, reduces sound levels and extends the life of the equipment. Step 8: When complete, calculate water temperature rise and assess the selection. If the units selected are not within 10% of the load calculations, then review what effect changing the gpm, water temperature and/or airflow and air temperature would have on the corrected capacities. If the desired capacity cannot be achieved, select the next larger or smaller unit and repeat the procedure. emember, when in doubt, undersize slightly for best performance. Example Equipment Selection - ooling 1. Load Determination: Assume we have determined that the appropriate cooling load at the desired dry bulb 80 F and wet bulb 65 F conditions is as follows: Total ooling...51,500 Btu/h Sensible ooling...34,300 Btu/h Entering Air Temp...75 F Dry Bulb / 65 F Wet Bulb 2. Design onditions: Similarly, we have also obtained the following design parameters: Entering Water Temp F Water Flow (Based upon 10 F rise in temp.) 15.0 gpm Airflow equired... 1, in. wg. Step 3: Select a unit based on total and sensible cooling conditions. Select a unit which is closest to, but no larger than, the actual cooling load. 50

51 Selection Example cont. 3, 4 & 5. HP Selection: After making our preliminary selection (UB*060 variable speed EM), we enter the tables at design water flow and water temperature and read Total ooling, Sens. ooling and Heat of ej. capacities: Total ooling...54,100 Btu/h Sensible ooling... 40,500 Btu/h Heat of ejection...68,800 Btu/h 6 & 7. Entering Air and Airflow orrections: Next, we determine our correction factors. (efer to orrection Factor Tables - Airflow and Entering Air correction tables using 1750 cfm. or 1,750 2,000 nom. = 87.5%). orrected Total ooling = 54,100 x x = 51,373 orrected Sens ooling = 40,500 x x = 33,147 orrected Heat of eject = 68,800 x x = 65,402 H = 500 x gpm x (T in - T out ) H = (T in - T out ) or T ise 500 x gpm 65, x 15 = 8.72 F ise 8. Water Temperature ise alculation & Assessment: NOTE: 500 = parameters for water & 485 = parameters for antifreeze solutions to 30% weight. When we compare the orrected Total ooling and orrected Sensible ooling figures with our load requirements stated in Step 1, we discover that our selection is within +10% of our sensible load requirement. Further more, we see that our orrected Total ooling figure is within 1,000 Btu/h of the actual indicated load. Antifreeze orrections atalog performance can be corrected for antifreeze use. Please use the following table and note the example given. Antifreeze Type Antifreeze % by wt ooling apacity Heating apacity Pressure Drop EWT - degf [Deg] 90 [32.2] 30 [-1.1] 30 [-1.1] Water Ethylene lycol Propylene lycol Ethanol Methanol Warning: ray area represents antifreeze concentrations greater than 35% by weight and should be avoided due to the extreme performance penalty they represent. Antifreeze orrection Example Antifreeze solution is Propylene lycol 20% by weight. Determine the corrected heating and cooling performance at 30 F and 90 F respectively as well as pressure drop at 30 F for a Versatec ompact Series UB*024-PS. The corrected cooling capacity at 90 F would be: 22,600 Btu/h x = 21,899 Btu/h The corrected heating capacity at 30 F would be: 16,800 Btu/h x = 15,338 Btu/h The corrected pressure drop at 30 F and 6 gpm would be: 20.8 ft. hd x = ft. hd. 51

52 eference alculations Heating alculations: ooling alculations: LWT = EWT - HE gpm x 500 H LWT = EWT + gpm x 500 LAT = EAT + H cfm x 1.08 LAT(DB) = EAT(DB) - S cfm x 1.08 TH = H + HW L = T - S S S/T = T 52

53 Legend and Notes ABBEVIATIONS AND DEFINITIONS: cfm = airflow, cubic feet/minute EWT = entering water temperature, Fahrenheit gpm = water flow in gallons/minute WPD = water pressure drop, psi and feet of water EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) H = air heating capacity, T = total cooling capacity, S = sensible cooling capacity, kw = total power unit input, kilowatts H = total heat of rejection, HE = total heat of extraction, HW = hot water generator capacity, EE = Energy Efficient atio = BTU output/watt input OP = oefficient of Performance = Btu output/btu input LWT = leaving water temperature, F LAT = leaving air temperature, F TH = total heating capacity, L = latent cooling capacity, S/T = sensible to total cooling ratio Notes (efer to Performance Data tables) Performance ratings are based on 80 F DB / 67 F WB EAT for cooling and 70 F DB EAT for heating. Three flow rates are shown for each unit. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum of 50 F EWT. The middle flow rate shown is the minimum geothermal closed loop flow rate. The highest flow rate shown is optimum for geothermal closed loop systems and the suggested flow rate for boiler/ tower applications. Entering water temperatures below 40 F assumes 15% antifreeze solution. For non-standard EAT conditions, apply the appropriate correction factors on (efer to orrection Factor Tables). Interpolation between EWT, gpm, and cfm data is permissible. 53

54 Operating Limits Operating Limits ooling Heating ( F) ( ) ( F) ( ) Air Limits Min. Ambient Air ated Ambient Air Max. Ambient Air Min. Entering Air ated Entering Air db/wb 80.6/ / Max. Entering Air db/wb 110/83 43/ Water Limits Min. Entering Water Normal Entering Water Max. Entering Water NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependent upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation. ooling apacity orrections Entering Air WB F Total lg ap Sensible ooling apacity Multipliers - Entering DB F Power Input Heat of ejection * * * * * * * * * * * * * * * * * * * NOTE: * Sensible capacity equals total capacity at conditions shown. 11/10/09 Heating orrections Ent Air DB F Htg ap Power Heat of Ext /10/09 Airflow orrections Airflow ooling Heating cfm Per Ton of lg % of Nominal Total ap Sens ap Power Heat of ej Htg ap Power Heat of Ext /10/09 54

55 Pressure Drop Model PM Pressure Drop (psi) Pressure Valve PM v 30 F 50 F 70 F 90 F 110 F Drop (psi) Internally mounted 2-position solenoid water valves are not available on models / / / / / N/A / / /15/15 10/15/15 55

56 UB006 - Performance Data Single Speed with PS (250 cfm) EWT F WATE FLOW PM PSI WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F FT H Power kw HE LAT F OP T S S/T atio Power kw H /9/2018 EE 56

57 UB009 - Performance Data Single Speed with PS (350 cfm) EWT F WATE FLOW PM PSI WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F FT H Power kw HE LAT F OP T S S/T atio Power kw H /9/2018 EE 57

58 UB012 - Performance Data Single Speed with PS (400 cfm) EWT F WATE FLOW PM WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F PSI FT H KW HE LAT OP T S S/T KW H EE /9/

59 UB015 - Performance Data Single Speed with PS (500 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /5/2012 EE 59

60 UB018 - Performance Data Single Speed with PS (600 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 60

61 UB024 - Performance Data Single Speed with PS (800 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 61

62 UB030 - Performance Data Single Speed with PS (1000 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 62

63 UB036 - Performance Data Single Speed with PS (1150 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 63

64 UB041 - Performance Data Single Speed - PS (1100 FM) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H EE /15/15 64

65 UB042 - Performance Data Single Speed with PS (1400 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /18/11 EE 65

66 UB048 - Performance Data Single Speed with PS (1600 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 66

67 UB060 - Performance Data Single Speed with PS (2000 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 67

68 UB070 - Performance Data Single Speed with PS (2200 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 68

69 UB006 - Performance Data Single Speed with EM (250 cfm) EWT F WATE FLOW PM WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F PSI FT H KW HE LAT OP T S S/T KW H EE /9/

70 UB009 - Performance Data Single Speed with EM (350 cfm) EWT F WATE FLOW PM WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F PSI FT H KW HE LAT OP T S S/T KW H EE /9/

71 UB012 - Performance Data Single Speed with EM (400 cfm) EWT F WATE FLOW PM WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F PSI FT H KW HE LAT OP T S S/T KW H EE /9/

72 UB015 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (500 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /5/2012 EE 72

73 UB018 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (600 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 73

74 UB024 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (800 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 74

75 UB030 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (1000 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 75

76 UB036 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (1150 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 76

77 UB041 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (1300 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /15/15 EE 77

78 UB042 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (1400 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 78

79 UB048 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (1600 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 79

80 UB060 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (2000 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 80

81 UB070 - Performance Data Single Speed with Variable Speed EM or 5-Speed EM (2200 cfm) EWT F Flow PM psi WPD HEATIN - EAT 70 F OOLIN - EAT 80/67 F ft H Power kw HE LAT F OP T S S/T atio Power kw H /1/11 EE 81

82 Wiring Schematics Aurora Base ontrol /60/1 PS ompressor rn P3 PS Blower Motor H M L Brn Wht ap 3 Airflow Settings White S Blue ap Black ed Tan T2 T1 L2 L1 Note 1 reen (93) Black (95) round Neutral Disconnect L1 L1 Unit Power Supply /60/1 Black B 1 3 Black ed (97) L2 L2 Note 2 ed 208V L3 L3 Blue 230V 265V Black Transformer 24V Yellow Black/White 470Ω esistor Note 3 Isolation Valve B V V FD T 470Ω LP HP ed (51) reen (50) White (52) ed (53) Note 3 EH1 P2 ES LS ALM AL A OM A NO A N LO O/B Y1 Y2 W DH P1 2 F K5-Alarm elay K6-Acc elay P8 P9 om2 LED5 S485 NET JW2 White (12) Black (13) Violet (14) om1 LED5 S485 NET - + P7 Black (15) F F 2 HI K4-Fan elay K2- elay 2 LO K3-2 elay 2 S485 EXP P5 Aurora Base ontrol (AB) Orange (01) Orange (02) Yellow Yellow Blue (07) Blue (08) Black (09) Black (10) EVEV FP1 FP1 FP2 FP2 LPS LPS HPSHPS P4 K1-V elay SW1 Test Mode - + P6 O EH1 EH2 P3 Status LED3 Y1 F1-3A PWM FM Fault LED1 P13 Off On FP1 15 F/30 F 1 FP2 15 F/30 F 2 V B/O 3 Acc Dip 4 4 Acc Dip 5 5 Dual/Single 6 L Output Type 7 Future Use 8 SW2 onfig LED2 Y F Black/White Yellow reen Brown (23) ondensate 82

83 Wiring Schematics cont. Aurora Base ontrol /60/1 PS 97P /14/2013 Notes: 1 Optional, factory installed unit mounted disconnect. 2 Swap blue and red leads for 208V operation. 3 Optional, factory installed internal isolation valve. Legend Factory Low Voltage Wiring Factory Line Voltage Wiring Field Low Voltage Wiring Field Line Voltage Wiring Optional Block D Voltage PB Traces Field Zone Sensor Wiring Internal Junction Quick onnect Terminal T Thermistor elay oil Switch - ondensate Overflow Switch - High pressure Switch - Low pressure L1 Field Wiring Lug Polarized connector round elay ontacts N.O., N.. Light Emitting Diode - reen apacitor Y Light Emitting Diode - Yellow Fuse ompressor ontactor O ondensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FD Freeze Detection Sensor F1 Fuse Light Emitting Diode - ed SW1 Push button SW2 DIP package 8 position B Blower elay V eversing Valve oil Aurora LED Flash odes Slow Flash Fast Flash Flash ode 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating andom Start Delay Status LED (LED1, reen) onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Status LED (LED1, reen) Fast Flash Fast Flash Fast Flash onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Normal Mode ON No Software Overide Flash EM Setting Normal Mode OFF ontrol is Non-Functional OFF DIP Switch Overide Slow Flash Input Fault Lockout Flash ode 1 Test Mode Slow Flash EM onfigure Mode Fast Flash High Pressure Lockout Flash ode 2 Lockout Active Dehumidification Mode eserved eserved Load Shed ESD eserved Fast Flash Flash ode 2 Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 eset onfigure Mode Off Low Pressure Lockout Low Air oil Limit Lockout - FP2 Low Water oil Limit Lockout - FP1 eserved ondensate Overflow Lockout Over/Under Voltage Shutdown eserved eserved Air/Water oil Limit Sensor Error Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 Flash ode 8 Flash ode 9 Flash ode 10 Flash ode 11 Aurora Timing Events Event Normal Mode Test Mode andom Start Delay 5 to 80 seconds 1 second ompressor On Delay 5 seconds < 1 second ompressor Minimum On Time 2 minutes 5 seconds ompressor Short ycle Delay 4 minutes 15 seconds Blower Off Delay 30 seconds 2 seconds Fault ecognition Delay High Pressure Start-Up Bypass Low Pressure Less than 1 second 2 minutes Less than 1 second 30 seconds Fault ecognition Delay Low Pressure 30 seconds 30 seconds Start-Up Bypass Low Water/Air oil Limit Fault ecognition Delay Low Water/Air oil Limit Fault ecognition Delay ondensate Overflow 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds Thermostat all ecognition Time 2 seconds 2 seconds Auxiliary Heat Staging Delay Emergency Heat Staging Delay 5 minutes 2 minutes 20 seconds 7.5 seconds Water Valve Slow Open Delay 90 seconds 90 seconds eheat Delay 30 seconds 30 seconds Accessory elay Operation SW2-4 SW2-5 ycle with Blower On On ycle with ompressor Off Off Water Valve Slow Open On Off Outdoor Air Damper Off On 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F P2 P4 Factory P5 Factory PWM FM EM PWM P13 SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Field onnections P9 LO P1 LED1 Off FP1 15 o F/30 o F FP2 15 o F/30 o F Fault V B/O A Dip 4 LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal Factory Use P11 AUOA BASE ONTOL Factory Fan onnection O/B Field onnections SW2 On 1 LED2 2 Y 3 onfig Y1 Y2 W DH om1 om2 3A-Fuse P3 Factory P6 P7 S 485 P8 EH1 S485 Exp S485 NET EH2 EH1 O N/A (+) (-) (+) (-) ES LS ALM AL A c A no A nc LO O/B Y1 Y2 W DH 83

84 Wiring Schematics cont. Aurora Base ontrol 460/60/3 5-Speed EM T3 T1 ed T2 Black Phase uard Monitor (PM) L1 L2 L3 L3 T3 Yellow T2 L2 T1 L1 Unit Power Supply 460/60/3 ed (9) White (8) Black (7) reen (93) Black (95) round Neutral Disconnect L1 L1 Yellow (96) L2 L2 Blue 460V Black ed (97) L3 L3 Brown Orange reen N L X13 Fan Motor PM Y-OUT Y Yellow Transfo rmer 24V Black/White Black/White (92) Yellow (91) ray (30) Tan (31) ed (32) Blue (33) Dual apacity Units Only Ultra Tech S V FD 470 esistor 470 LP HP Black (35) T V ed (51) reen (50) White (52) ed (53) Note 2 P2 ES LS ALM AL A OM A NO A N LO P1 O/B Y1 Y2 W DH EH1 2 F K5-Alarm elay K6-Acc elay P9 LED4 om2 LED5 S485 NET P8 JW2 Violet (14) LED5 om1 LED5 S485 NET - + P7 Black (15) F F 2 HI K4-Fan elay K2- elay P Blue(16) Blue(18) 2 LO K3-2 elay 2 S485 EXP P5 Aurora Base ontrol (AB) Orange (01) Orange (02) Yellow Yellow Blue (07) Blue (08) Black (09) Black (10) EVEVFP1 FP1 FP2 FP2 LPS LPSHPSHPS P4 K1-V elay SW1 Test Mode - + P6 O EH1 EH2 P3 Status LED3 Y1 Faul t LED1 F1-3A Off FP1 15 F/30 F FP2 15 F/30 F V B/O Acc Dip 4 Acc Dip 5 Dual/Single L Output Type Future Use onfig LED2 Y F PWM FM P13 SW2 On Black/White Yellow reen Brown (23) ondensate 84

85 Wiring Schematics cont. Aurora Base ontrol 460/60/3 5-Speed EM Notes: 1 Optional, factory installed unit mounted disconnect. 2 Optional, factory installed internal isolation valve. 3 Optional, factory installed phase guard 4 Optional, factory installed phase guard. The yellow transformer wire shall be connected directly to the PU board, if this option is not installed. 5 Wire is provided with the unit but only connected to the X13 motor for dual capacity units. Factory Low Voltage Wiring Factory Line Voltage Wiring Field Low Voltage Wiring Fi eld Li ne Voltage Wi ri ng Optional Block D Voltage PB Traces Fi eld Zone Sensor Wi ri ng Internal Junction Qui ck on nect Terminal Legend T Thermistor elay oil Switch - ondensate Overflow Switch - High pressure Switch - Low pressure L1 Fi eld Wiring Lug Polarized connector round elay ontacts N.O., N.. Light Emitting Diode - reen apacitor Y Light Emitting Diode - Yellow Fuse ompressor ontactor O ondensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FD Freeze Detection Sensor F1 Fuse Light Emitting Diode - ed SW1 Push button SW2 DIP package 8 position B Blower elay V eversing Valve oil PM Phase uard Monitor H eheat Valve oi l Aurora LED Flash odes Slow Flash Fast Flash Flash ode 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating andom Start Delay Status LED (LED1, reen) onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Status LED (LED1, reen) Fast Fl ash Fast Fl ash Fast Fl ash onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Normal Mode ON No Software Overide Flash EM Setting Normal Mode OFF ontrol is Non-Functional OFF DIP Switch Overide Slow Flash Input Fault Lockout Flash ode 1 Test Mode Slow Flash EM onfigure Mode Fast Flash High Pressure Lockout Flash ode 2 Lockout Active Dehumidification Mode eserved eserved Load Shed ESD eserved Fast Fl ash Flash ode 2 Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 eset onfigure Mode Off Low Pressure Lockout Low Air oil Limit Lockout - FP2 Low Water oil Limit Lockout - FP1 eserved ondensate Overflow Lockout Over/Under Voltage Shutdown eserved eserved Air/Water oil Limit Sensor Error Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 Flash ode 8 Flash ode 9 Flash ode 10 Flash ode 11 Accessor y elay Operation SW2-4 SW2-5 ycl e with Blower On On ycle with ompressor Off Off Water Valve Slow Open On Off Outdoor Air Damper Off On Aurora Timing Events Event Normal Mode Test Mode andom Start Delay 5 to 80 seconds 1 second ompressor On Delay 5 seconds < 1 second ompressor Minimum On Time 2 minutes 5 seconds ompressor Short ycle Delay 4 minutes 15 seconds Blower Off Delay 30 seconds 2 seconds Fault ecognition Delay High Pressure Less than 1 second Less than 1 second Start-Up Bypass Low Pressure 2 minutes 30 seconds Fault ecognition Delay Low Pressure 30 seconds 30 seconds Start-Up Bypass Low Water/Air oil Limit Fault ecognition Delay Low Water/Air oil Limit Fault ecognition Delay ondensate Overflow 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds Thermostat all ecognition Time 2 seconds 2 seconds Auxi liary Heat Stagi ng Del ay Emergency Heat Stagi ng Dela y 5 minutes 2 minutes 20 seconds 7.5 seconds Water Valve Slow Open Delay 90 seconds 90 seconds eheat Delay 30 seconds 30 seconds 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F P2 ES P4 Factory P5 Factory LS PWM FM EM PWM P13 ALM AL SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Fi eld onnections A c A no A nc P9 LO P1 LO LED1 P11 Off FP1 15 o F/30 o F FP2 15 o F/30 o F Faul t V B/O A Dip 4 LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal Factory Use AUOA BASE ONTOL Factory Fan onnection O/B Fi eld onnections O/B SW2 On 1 LED2 2 Y 3 onfig Y1 Y2 W Y1 Y2 W DH DH om1 om2 3A-Fuse P3 Factory P6 S 485 EH1 S485 Exp P7 P8 S485 NET EH2 EH1 O N/A (+) (-) Page 1 85

86 Wiring Schematics cont. Aurora Base ontrol 460/60/3 Variable Speed EM ompressor L3 T3 ed T3 T1 T2 Yellow Black T2 T1 L2 L1 Phase uard Monitor (PM) L1 L2 L3 Orange Brown PB3 N reen (93) ray (94) round Neutral Disconnect Unit Power Supply 460/60/3 w/neutral Black (7) Black (54) L1 Black (95) L1 L1 White (8) ed (9) Blue (55) L2 Yellow (96) L2 L2 Black (54) ed (56) L3 ed (97) L3 L3 Blue (55) ed (56) Blue 460V Black Orange Transfo rmer reen Br own PM Y-OUT Y Yellow 24V Black/White P11 Black/White (92) Yellow (91) EM2 Fan Motor Dual apacity Units Only Ultra Tech S V FD 470 esistor 470 LP HP PWM FM P12 T V ed (51) reen (50) White (52) ed (53) Note 2 P2 ES LS ALM AL A OM A NO A N LO O/B Y1 Y2 W DH P1 EH1 2 F K5-Alarm elay K6-Acc elay P8 P9 om2 LED5 S485 NET JW2 Violet (14) om1 LED5 S485 NET - + P7 Black (15) F F 2 HI K4-Fan elay K2- el ay P Blue(16) Blue(18) 2 LO K3-2 elay 2 S485 EXP P5 Aurora Base ontrol (AB) Orange (01) Orange (02) Yellow Yellow Blue (07) Blue (08) Black (09) Black (10) EVEVFP1 FP1 FP2 FP2 LPS LPSHPSHPSP4 K1-V elay SW1 Test Mode - + P6 O EH1 EH2 P3 Status LED3 Y1 Faul t LED1 F1-3A PWM FM P13 Off On FP1 15 F/30 F 1 FP2 15 F/30 F 2 V B/O 3 Acc Dip 4 4 Acc Dip 5 5 Dual/Single 6 L Output Type 7 Future Use 8 SW2 onfig LED2 Y F Black/White Yellow Violet (42) Blue (24) Yellow (25) reen/yellow (28) reen Brown (23) ondensate 86

87 Wiring Schematics cont. Aurora Base ontrol 460/60/3 Variable Speed EM Notes: Legend 1 Optional, factory installed unit mounted disconnect. 2 Optional, fac tory installed internal isolation valve. 3 Optional, factory installed phase guard 4 Optional, factory installed phase guard. The yellow transformer wire shall be connected directly to the PU board, if this option is not installed. Factory Low Voltage Wiring Factory Line Voltage Wiring Field Low Voltage Wiring Fi eld Li ne Voltage Wi ri ng Optional Block D Voltage PB Traces Fi eld Zone Sensor Wi ri ng Internal Junction Qui ck on nect Terminal T Thermistor elay oil Switch - ondensate Overflow Switch - High pressure Switch - Low pressure L1 Fi eld Wiring Lug Polarized connector round elay ontacts N.O., N.. Light Emitting Diode - reen apacitor Y Light Emitting Diode - Yellow Fuse ompressor ontactor O ondensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FD Freeze Detection Sensor F1 Fuse Light Emitting Diode - ed SW1 Push button SW2 DIP package 8 position B Blower elay V eversing Valve oil PM Phase uard Monitor H eheat Valve oi l Aurora LED Flash odes Slow Flash Fast Flash Flash ode 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating andom Start Delay Status LED (LED1, reen) onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Status LED (LED1, reen) Fast Fl ash Fast Fl ash Fast Fl ash onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Normal Mode ON No Software Overide Flash EM Setting Normal Mode OFF ontrol is Non-Functional OFF DIP Switch Overide Slow Flash Input Fault Lockout Flash ode 1 Test Mode Slow Flash EM onfigure Mode Fast Flash High Pressure Lockout Flash ode 2 Lockout Active Dehumidification Mode eserved eserved Load Shed ESD eserved Fast Fl ash Flash ode 2 Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 eset onfigure Mode Off Low Pressure Lockout Low Air oil Limit Lockout - FP2 Low Water oil Limit Lockout - FP1 eserved ondensate Overflow Lockout Over/Under Voltage Shutdown eserved eserved Air/Water oil Limit Sensor Error Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 Flash ode 8 Flash ode 9 Flash ode 10 Flash ode 11 Accessor y elay Operation SW2-4 SW2-5 ycl e with Blower On On ycle with ompressor Off Off Water Valve Slow Open On Off Outdoor Air Damper Off On Aurora Timing Events Event Normal Mode Test Mode andom Start Delay 5 to 80 seconds 1 second ompressor On Delay 5 seconds < 1 second ompressor Minimum On Time 2 minutes 5 seconds ompressor Short ycle Delay 4 minutes 15 seconds Blower Off Delay 30 seconds 2 seconds Fault ecognition Delay High Pressure Less than 1 second Less than 1 second Start-Up Bypass Low Pressure 2 minutes 30 seconds Fault ecognition Delay Low Pressure 30 seconds 30 seconds Start-Up Bypass Low Water/Air oil Limit Fault ecognition Delay Low Water/Air oil Limit Fault ecognition Delay ondensate Overflow 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds Thermostat all ecognition Time 2 seconds 2 seconds Auxi liary Heat Stagi ng Del ay Emergency Heat Stagi ng Dela y 5 minutes 2 minutes 20 seconds 7.5 seconds Water Valve Slow Open Delay 90 seconds 90 seconds eheat Delay 30 seconds 30 seconds 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F P2 P4 Factory P5 Factory PWM FM EM PWM P13 SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Fi eld onnections Off LED1 FP1 15 o F/30 o F FP2 15 o F/30 o F Faul t V B/O A Dip 4 LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal P9 LO P1 Factory Use P11 AUOA BASE ONTOL Factory Fan onnection O/B Fi eld onnections SW2 On 1 LED2 2 Y 3 onfig Y1 Y2 W DH om1 om2 3A-Fuse P3 Factory P6 S 485 EH1 S485 Exp P7 P8 S485 NET EH2 EH1 O N/A (+) (-) ES LS ALM AL A c A no A nc LO O/B Y1 Y2 W DH 87 Page 1

88 Wiring Schematics cont. ommercial Aurora with Variable Speed EM Motor /60/1 ompressor S Blue ap Black ed Tan T2 T1 Unit Power Supply /60/1 L2 L1 reen (93) round Neutral Disconnect Black (95) L1 L1 ed (97) L2 L2 ed 208V Blue 230V Black L3 L3 Black ed lass 2 Transfo rmer 24V Yellow Black/White EM Fan Motor Dual apacity Units Only Ultra Tech V FP 470 esistor LP HP S 470 T V ed (51) reen (50) White (52) ed (53) Note 3 P2 ES LS ALM AL A OM A NO A N LO P1 O/B Y1 Y2 W DH EH1 2 F K5-Alarm elay K6-Acc elay P8 P9 om2 LED5 S485 NET JW2 Violet (14) om1 LED5 S485 NET - + P7 Black (15) F F 2 HI K4-Fan elay K2- elay P Blue(16) Blue(18) 2 LO K3-2 elay 2 S485 EXP P5 Aurora Base ontrol (AB) Orange (01) Orange (02) Yellow Yellow Blue (07) Blue (08) Black (09) Black (10) EVEVFP1 FP1 FP2 FP2 LPS LPSHPSHPSP4 K1-V elay SW1 Test Mode - + P6 O EH1 EH2 P3 Status LED3 Y1 F1-3A PWM FM Faul t LED1 P13 Off On FP1 15 F/30 F 1 FP2 15 F/30 F 2 V B/O 3 Acc Dip 4 4 Acc Dip 5 5 Dual/Single 6 L Output Type 7 eheat/normal 8 SW2 onfig LED2 Y F Black/White Yellow Yellow Blue reen Brown (23) ondensate ray (61) H ray (60) Note 4 88

89 Wiring Schematics cont. ommercial Aurora with Variable Speed EM Motor /60/1 Notes: 1 Optional, factory installed unit mounted disconnect. 2 Swap blue and red leads for 208V operation. 3 Optional, factory installed internal isolation valve. 4 Optional, factory installed reheat. Factory Low Voltage Wiring Factory Line Voltage Wiring Field Low Voltage Wiring Fi eld Li ne Voltage Wi ri ng Optional Block D Voltage PB Traces Fi eld Zone Sensor Wi ri ng Internal Junction Quick onnect Terminal Legend T Thermistor elay oil Switch - ondensate Overflow Switch - High pressure Switch - Low pressure 97P /27/17 L1 Fi eld Wiring Lug Polarized connector round elay ontacts N.O., N.. Light Emitting Diode - reen apacitor Y Light Emitting Diode - Yellow Fuse ompressor ontactor O ondensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FP Freeze Protection F1 Fuse Light Emitting Diode - ed SW1 Push button SW2 DIP package 8 position B Blower elay V eversing Valve oil PM Phase uard Monitor H eheat Valve oi l Aurora LED Flash odes Slow Flash Fast Flash Flash ode 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating andom Start Delay Status LED (LED1, reen) onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Status LED (LED1, reen) Fast Fl ash Fast Fl ash Fast Fl ash onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Normal Mode ON No Software Overide Flash EM Setting Normal Mode OFF ontrol is Non-Functional OFF DIP Switch Overide Slow Flash Input Fault Lockout Flash ode 1 Test Mode Slow Flash EM onfigure Mode Fast Flash High Pressure Lockout Flash ode 2 Lockout Active Dehumidification Mode eserved eserved Load Shed ESD eserved Fast Fl ash Flash ode 2 Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 eset onfigure Mode Off Low Pressure Lockout Low Air oil Limit Lockout - FP2 Low Water oil Limit Lockout - FP1 eserved ondensate Overflow Lockout Over/Under Voltage Shutdown eserved eserved Air/Water oil Limit Sensor Error Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 Flash ode 8 Flash ode 9 Flash ode 10 Flash ode 11 Accessor y elay Operation SW2-4 SW2-5 ycle with Blower On On ycle with ompressor Off Off Water Valve Slow Open On Off Outdoor Air Damper Off On Aurora Timing Events Event Normal Mode Test Mode andom Start Delay 5 to 80 seconds 1 second ompressor On Delay 5 seconds < 1 second ompressor Minimum On Time 2 minutes 5 seconds ompressor Short ycle Delay 4 minutes 15 seconds Blower Off Delay 30 seconds 2 seconds Fault ecognition Delay High Pressure Less than 1 second Less than 1 second Start-Up Bypass Low Pressure 2 minutes 30 seconds Fault ecognition Delay Low Pressure 30 seconds 30 seconds Start-Up Bypass Low Water/Air oil Limit Fault ecognition Delay Low Water/Air oil Limit Fault ecognition Delay ondensate Overflow 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds Thermostat all ecognition Time 2 seconds 2 seconds Auxi liary Heat Stagi ng Del ay Emergency Heat Stagi ng Dela y 5 minutes 2 minutes 20 seconds 7.5 seconds Water Valve Slow Open Delay 90 seconds 90 seconds eheat Delay 30 seconds 30 seconds 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F P2 P4 Factory P5 Factory PWM FM EM PWM P13 SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Fi eld onnections ES LS ALM AL A c A no A nc Off LED1 FP1 15 o F/30 o F FP2 15 o F/30 o F Faul t V B/O A Dip 4 LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal P9 LO P1 LO Factory Use P11 AUOA BASE ONTOL Factory Fan onnection O/B Fi eld onnections O/B SW2 On 1 LED2 2 Y 3 onfig Y1 Y2 W Y1 Y2 W DH DH om1 om2 3A-Fuse P3 Factory P6 S 485 EH1 S485 Exp P7 P8 S485 NET EH2 EH1 O N/A (+) (-) Page 1 89

90 Wiring Schematics cont. ommercial Aurora with Variable Speed EM Motor /60/1 ompressor S Blue ap Black ed Tan T2 T1 Unit Power Supply /60/1 L2 L1 reen (93) round Neutral Disconnect Black (95) L1 L1 ed (97) L2 L2 ed 208V Blue 230V Black L3 L3 Black ed lass 2 Transfo rmer 24V Yellow Black/White EM Fan Motor Dual apacity Units Only Ultra Tech V FP 470 esistor LP HP S 470 T V ed (51) reen (50) White (52) ed (53) Note 3 P2 ES LS ALM AL A OM A NO A N LO P1 O/B Y1 Y2 W DH EH1 2 F K5-Alarm elay K6-Acc elay P8 P9 om2 LED5 S485 NET JW2 Violet (14) om1 LED5 S485 NET - + P7 Black (15) F F 2 HI K4-Fan elay K2- el ay P Blue(16) Blue(18) 2 LO K3-2 elay 2 S485 EXP P5 Aurora Base ontrol (AB) Orange (01) Orange (02) Yellow Yellow Blue (07) Blue (08) Black (09) Black (10) EVEVFP1 FP1 FP2 FP2 LPS LPSHPSHPS P4 K1-V elay SW1 Test Mode - + P6 O EH1 EH2 P3 Status LED3 Y1 F1-3A PWM FM Faul t LED1 P13 Off On FP1 15 F/30 F 1 FP2 15 F/30 F 2 V B/O 3 Acc Dip 4 4 Acc Dip 5 5 Dual/Single 6 L Output Type 7 eheat/normal 8 SW2 onfig LED2 Y F Black/White Yellow Yellow Blue reen Brown (23) ondensate ray (61) H ray (60) Note 4 90

91 Wiring Schematics cont. ommercial Aurora with Variable Speed EM Motor /60/1 Notes: 1 Optional, factory installed unit mounted disconnect. 2 Swap blue and red leads for 208V operation. 3 Optional, factory installed internal isolation valve. 4 Optional, factory installed reheat. Factory Low Voltage Wiring Factory Line Voltage Wiring Field Low Voltage Wiring Fi eld Li ne Voltage Wi ri ng Optional Block D Voltage PB Traces Fi eld Zone Sensor Wi ri ng Internal Junction Qui ck on nect Terminal Legend T Thermistor elay oil Switch - ondensate Overflow Switch - High pressure Switch - Low pressure L1 Fi eld Wiring Lug Polarized connector round elay ontacts N.O., N.. Light Emitting Diode - reen apacitor Y Light Emitting Diode - Yellow Fuse ompressor ontactor O ondensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FP Freeze Protection F1 Fuse Light Emitting Diode - ed SW1 Push button SW2 DIP package 8 position B Blower elay V eversing Valve oil PM Phase uard Monitor H eheat Valve oi l Aurora LED Flash odes Slow Flash Fast Flash Flash ode 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating andom Start Delay Status LED (LED1, reen) onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Status LED (LED1, reen) Fast Fl ash Fast Fl ash Fast Fl ash onfiguration LED (LED2, Yellow) Fault LED (LED3, ed) Normal Mode ON No Software Overide Fl ash EM Settin g Normal Mode OFF ontrol is Non-Functional OFF DIP Switch Overide Slow Flash Input Fault Lockout Flash ode 1 Test Mode Slow Flash EM onfigure Mode Fast Flash High Pressure Lockout Flash ode 2 Lockout Active Dehumidification Mode eserved eserved Load Shed ESD eserved Fast Fl ash Flash ode 2 Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 eset onfigure Mode Off Low Pressure Lockout Low Air oil Limit Lockout - FP2 Low Water oil Limit Lockout - FP1 eserved ondensate Overflow Lockout Over/Under Voltage Shutdown eserved eserved Air/Water oil Limit Sensor Error Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 Flash ode 7 Flash ode 8 Flash ode 9 Flash ode 10 Flash ode 11 Accessor y elay Operation SW2-4 SW2-5 ycl e with Blower On On ycle with ompressor Off Off Water Valve Slow Open On Off Outdoor Air Damper Off On Aurora Timing Events Event Normal Mode Test Mode andom Start Delay 5 to 80 seconds 1 second ompressor On Delay 5 seconds < 1 second ompressor Minimum On Time 2 minutes 5 seconds ompressor Short ycl e Delay 4 minutes 15 seconds Blower Off Delay 30 seconds 2 seconds Fault ecognition Delay High Pressure Less than 1 second Less than 1 second Start-Up Bypass Low Pressure 2 minutes 30 seconds Fault ecognition Delay Low Pressure 30 seconds 30 seconds Start-Up Bypass Low Water/Air oil Limit Fault ecognition Delay Low Water/Air oil Limit Fault ecognition Delay ondensate Overflow 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds Thermostat all ecognition Time 2 seconds 2 seconds Auxiliary Heat Staging Delay Emergency Heat Stagi ng Dela y 5 minutes 2 minutes 20 seconds 7.5 seconds Water Valve Slow Open Delay 90 seconds 90 seconds eheat Delay 30 seconds 30 seconds 2 2 F Y1 JW2 - Alarm HP HP LP LP FP2 FP2 FP1 FP1 EV EV LO HI F F P2 ES P4 Factory P5 Factory LS PWM FM EM PWM P13 ALM AL A c SW1 Test V K1 K2 Hi K3 Fan K4 Alarm K5 Acc K6 Fi eld onnections A no A nc P9 LO P1 LO LED1 Off FP1 15 o F/30 o F FP2 15 o F/30 o F Faul t V B/O A Dip 4 LED3 A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal Factory Use P11 AUOA BASE ONTOL Factory Fan onnection O/B O/B Y1 Y1 Y2 Fi eld onnections Y2 SW2 W W On 1 LED DH DH Y onfig om1 om2 3A-Fuse P3 Factory P6 S 485 EH1 S485 Exp P7 P8 S485 NET EH2 EH1 O N/A (+) (-) Page 1 91

92 Wiring Schematics cont. Aurora ontrol with UP To AB - P BAnet or N2 Network onnections Devices Must Be Wired in Daisy hain onfiguration Orange ed White Black Blue reen Brown Yellow Optional LON Add-On Module LON O NET+ NET- NET- OM NET+ OM NET+ NET- POWE ND 24 VA LON Network onnections OM NET+ LED1 TX LED2 X LED3 POWE FOMAT BATT Devices Must Be Wired in Daisy hain onfiguration 2 1 Service LED1 LED2 Tx LED3 x Net LED4 1 2 EHELON NET- N/ N/ Signal ND NET+ NET- +12V NET LED7 2W X 4W ND LN+ LN- +12 /S LON ADAPTE POT LED6 TX LOAL AESS LED4 LED5 UN E ON TEN S ONE S ommunication Options NOTE 1 MA Address Setting 1 2 ZS Sensor 1 Addr: 0 ND NET+ NET- +12V ZS Sensor 2 Addr: 1 ND NET+ NET- +12V ZS Sensor 3 Addr: 2 ND NET+ NET- +12V ZS Sensor Information Zone Sensors can be wired in daisy chain as show or in a star or hybrid configuration. Maximum of 5 sensors per UP. Maximum allowable load 210mA. See the UP install manual for possible sensor combinations. Notes 1. Use DIP Switches 5 8 to change communication protocol and DIP switches 1 2 to change BAnet baud rate DIP Switch Value ON Each ZS sensor must have a unique address, but the addresses do not need to be sequential. Use the DIP switches on the back of the ZS sensor to set an address from 0 to 4. (0 is the factory default.) Each DIP switch has the value shown in the figure to the left. Turn on as many DIP switches as you need so that their total value equals the address. Legend Factory Low Voltage Wiring Field Low Voltage Wiring J45 onnector Page 1 92

RB Series. RB Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features.

RB Series. RB Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features. RB Series ommercial Water Source/eothermal Heat Pump R-410A Refrigerant 0.5-6 Ton RB Series Engineering uide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.5 to 6 Ton Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature.............................................................. 4 AHRI Data......................................................................

More information

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN ABO BASE SEIES O M M E I A L U N I T S AFFODABLE ENEWABLE LEAN Table of ontents Model Nomenclature.............................................................. 4 AHI Data.....................................................................

More information

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.5 to 6 Ton Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature........................................................... 4 AHRI Data...................................................................5-6

More information

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features.

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features. RG Series Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant 0.75-6 Ton RG Series Engineering Guide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features.

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features. R Series Commercial eothermal/water Source Heat Pump R-410A Refrigerant 0.75-6 Ton R Series Engineering uide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN Table of Contents Model Nomenclature.............................................................. 4 AHRI Data.....................................................................

More information

ARBOR SERIES AFFORDABLE RENEWABLE CLEAN

ARBOR SERIES AFFORDABLE RENEWABLE CLEAN ARBOR SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN Table of Contents Model Nomenclature............................................................. 4 AHRI Data.....................................................................

More information

RK Series. RK Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features.

RK Series. RK Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features. RK Series Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant 0.75-6 Ton RK Series Engineering Guide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SPECIFICATION CATALOG LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement,

More information

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18 ABO OMPAT SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZ 08/18 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21-22 23 Z B V 036 T L 0 0 0 A N A

More information

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity)

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Specification atalog 5 Series 500A eothermal heat pump -6 ton (single speed) 2-6 ton (dual capacity) Table of ontents Model Nomenclature............................................................ 5 AHI/ISO

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16 ABO BASE SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZB 03/16 Model Nomenclature 1 2 2 3-5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20-21 22 Z B V 036 T L 0 0 0 A N A N

More information

SPECIFICATION CATALOG

SPECIFICATION CATALOG SPEIFIATION ATALO EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN ASTON SEIES ASTON SEIES SPEIFIATION ATALO Table of ontents Model Nomenclature...............................................................

More information

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity)

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Specification atalog 5 Series 500A eothermal heat pump -6 ton (single speed) 2-6 ton (dual capacity) 5 SEIES 500A SPEIFIATION ATALO Table of ontents Model Nomenclature............................................................

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14 ARBOR BASE SERIES OMMERIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD0AZA 05/4 Model Nomenclature -5 6 7 8 9 0 4 5 6 7 8 9 0- Z B V 06 T L 0 0 0 A N A N A 0 SS * Model Type Z Arbor Operation

More information

AFFORDABLE RENEWABLE CLEAN

AFFORDABLE RENEWABLE CLEAN Specification atalog GEOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN Aston Series Indoor Split Table of ontents General Introduction... 4 Model Nomenclature... 5 AHI Data... 6-7 Design Features..................................................................8

More information

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY SPEIFIATION ATALOG GEOTHEMAL/WATE SOUE INDOO SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL APAITY Table of ontents Introduction... 4 Model Nomenclature.... 5 AHI Data... 6-7 Design Features...

More information

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity)

Specification Catalog. 5 Series 500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Specification atalog 5 Series 500A eothermal heat pump -6 ton (single speed) -6 ton (dual capacity) 5 SEIES 500A SPEIFIATION ATALO Table of ontents Model Nomenclature... 5 AHI/ISO 56- Performance atings....

More information

Specification Catalog. 5 Series 500R11. Indoor Split Geothermal Heat Pump 2-6 ton (single speed) 2-6 ton (dual capacity)

Specification Catalog. 5 Series 500R11. Indoor Split Geothermal Heat Pump 2-6 ton (single speed) 2-6 ton (dual capacity) Specification atalog 5 Series 50011 Indoor Split eothermal Heat Pump 2-6 ton (single speed) 2-6 ton (dual capacity) 5 SEIES 50011 SPEIFIATION ATALO Table of ontents The 5 Series......................................................................

More information

NSW GEOTHERMAL HYDRONIC HEAT PUMP 1.5 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2556WN 06/16

NSW GEOTHERMAL HYDRONIC HEAT PUMP 1.5 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2556WN 06/16 NSW EOTMAL HYDONI AT PUMP 1. TO 6 TONS Submittal Data English Language IP/Metric Units SD26WN 06/16 ontractor: VESATE ULTA NSW HYDONI 1. TO 6 TONS Model Nomenclature 1- -6 8 9 11 NSW 00 H 2 0 A 12 1-1

More information

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 500O11 Outdoor Split eothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 ontractor: 5 Series 500O11 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15

More information

ComPACT. Commercial kw Water Source/Geothermal Heat Pump - 50Hz. Submittal Data English Language/IP Units SD1025AN 07/12

ComPACT. Commercial kw Water Source/Geothermal Heat Pump - 50Hz. Submittal Data English Language/IP Units SD1025AN 07/12 ompat ommercial 005-017 Water Source/eothermal Heat Pump - 50Hz Submittal Data English Language/IP Units SD1025AN 07/12 Model Nomenclature 1-3 NBK 4 V 5-7 009 8 T 9 L 10 7 11 0 12 4 13 14 A 15 N 16 A 17

More information

ASTON SERIES SINGLE HYDRONIC Residential Ton Water-to-Water Geothermal Heat Pump

ASTON SERIES SINGLE HYDRONIC Residential Ton Water-to-Water Geothermal Heat Pump ASTON SEIES SINLE HYDONI esidential 1. - 6 Ton Water-to-Water eothermal Heat Pump Submittal Data English Language IP/Metric Units SD206W 06/16 ontractor: Model Nomenclature 1-2 - 8 9 11 12 1 1 * 00 A 1

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase

More information

ASTON SERIES. SINGLE HYDRONIC Residential 3-5 Ton Water-to-Water Geothermal Heat Pump. Submittal Data English Language IP/Metric Units SD2508WG 05/15

ASTON SERIES. SINGLE HYDRONIC Residential 3-5 Ton Water-to-Water Geothermal Heat Pump. Submittal Data English Language IP/Metric Units SD2508WG 05/15 ASTON SEIES SINLE HYDONI esidential 3 - Ton Water-to-Water eothermal Heat Pump Submittal Data English Language IP/Metric Units SD20W 0/ ontractor: ASTON SINLE HYDONI WITH OPTIHEAT Model Nomenclature 1-2

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY OUTDOO SPLIT EOTHEMAL HEAT PUMPS DUAL APAITY MODELS: YAST026-072 (2 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs

More information

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...

More information

NXW 10 TO 50 TON. Commercial Reversible Chiller - 60 Hz. Submittal Data English Language IP/Metric Units SD2502WNB 08/16

NXW 10 TO 50 TON. Commercial Reversible Chiller - 60 Hz. Submittal Data English Language IP/Metric Units SD2502WNB 08/16 NXW 10 TO 50 TON ommercial eversible hiller - Hz Submittal Data English Language IP/Metric Units SD2502WNB 08/16 Model Nomenclature Model Type NXW Envision n 2 Series eversible hiller Unit apacity (MBTUH)

More information

DCH Commercial Contents Standard Features Cabinet Features

DCH Commercial Contents Standard Features Cabinet Features DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8

More information

Aston Series GEOTHERMAL HEAT PUMPS 1 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2500AG 09/15

Aston Series GEOTHERMAL HEAT PUMPS 1 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2500AG 09/15 EOTHEMAL HEAT PUMPS TO 6 TONS Submittal Data English Language IP/Metric Units SD500A 09/5 ontractor: Model Nomenclature - 3 4 5-7 8 9 0 3 4 0 * 036 T L 0 5 0 6 A 7 0 Model Type 0 Aston Water-to-Air Type

More information

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET LX SERIES EOTHERMAL HEAT PUMPS DUAL APAITY MODELS: YLF026-072 (2 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change

More information

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14 ASTON SERIES COMPACT Commercial 0.75-6 Ton Water Source/Geothermal Heat Pump Submittal Data English Language/IP Units SD1022AGA 05/14 Model Nomenclature 1-2 3 4-6 7 8 9 10 11 12 13 14 GB V 048 T L 0 0

More information

Envision Indoor Split Specification Catalog

Envision Indoor Split Specification Catalog Envision Series Geothermal Indoor Split Heat Pumps -410A efrigerant 2 thru 6 Ton Single Speed 2 thru 6 Ton Dual apacity Design Features Factory Options Accessories Dimensional Data Physical Data Performance

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2500AN 11/17

500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2500AN 11/17 500A eothermal heat pump -6 ton (single speed) -6 ton (dual capacity) Submittal Data English Language/IP Units SD500AN /7 ontractor: Model Nomenclature 4-6 7 8 9 0 4 N D V 049 * T L 0 5 A 6 N ompressor

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY EOTHEMAL HEAT PUMPS DUAL APAITY OMBINATION MODELS: YAT038-07 (3 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h PH ommercial ooling apacity: 5, 7, BU/h Heating apacity: 4,6 7, BU/h - to 6-on Packaged Heat Pump SEE / up to. EE & 7.7 HSPF Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18

More information

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE DT ommercial 5 Tons as/ Electric Units Up to 5.5 SEE and.0 EE Up to 8% AFUE ooling apacity: 5,600 60,000 BTU/h Heating apacity: 6,000 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

LOW SILL CONSOLE R-410A Refrigerant Ton. Submittal Data English Language/IP Units SD1012CNB 09/15

LOW SILL CONSOLE R-410A Refrigerant Ton. Submittal Data English Language/IP Units SD1012CNB 09/15 SILL ONSOLE -410A efrigerant 0.75-1.5 Ton Submittal Data English Language/IP Units SD1012NB 09/15 ontractor: ENVISION ommercial Series Low Sill onsole 0.75-1.5 Ton - 60Hz Model Nomenclature 1-2 3 4-5 6

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET AFFINITY COMPACT COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE AND DUAL CAPACITY MODELS: YKS009-0 (.75 THRU 6 NOMINAL TONS) YKT026-072 (2 THRU 6 NOMINAL

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

SPECIFICATION CATALOG. Commercial 0.75 to 6 Tons. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.75 to 6 Tons. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.75 to 6 Tons Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature.... 2 The Envision Series...3-8 Design Features... 9-11 Envision Controls....12-22

More information

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

Residential Packaged Geothermal Heat Pump

Residential Packaged Geothermal Heat Pump ENGIneering Design Guide Residential Packaged Geothermal Heat Pump HP Series 1 1 /2 to 5 Tons Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Engineering

More information

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency

More information

Specification Catalog. 3 Series 300A11. Geothermal heat pump 2-6 ton (dual capacity)

Specification Catalog. 3 Series 300A11. Geothermal heat pump 2-6 ton (dual capacity) Specification Catalog 3 Series 300A11 eothermal heat pump 2-6 ton (dual capacity) Table of Contents Model Nomenclature............................................................ 5 AHRI/ISO 13256-1 Performance

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog Catalog 1100-6 McQuay Enfinity TM Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060 Model FCV & FCW Vertical Floor Size 007 060 Table of Contents

More information

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY LOW SILL ONSOLE OMMEIAL EOTHEMAL/ WATE SOUE HEAT PUMPS SINLE APAITY MODELS: YL09-18 (.75 THU 1.5 NOMINAL TONS) Due to continuous product improvement,

More information

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SPECIFICATION CATALO LX SERIES EOTHERMAL HEAT PUMPS SINLE AND DUAL CAPACITY MODELS: YLF 026-072 (2 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger GPG14M ooling apacity: 23,000 to 57,500 BTU/h Heating apacity: 40,000 to 120,000 BTU/h Packaged Gas / Electric Units 2 to 5 Tons 14 SEER / 81% AFUE ontents Nomenclature... 2 Product Specifications... 3

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Tranquility Water-To-Water (TMW) Series

Tranquility Water-To-Water (TMW) Series Tranquility Water-To-Water (TMW) Series Submittal Data Model TMW036-340 60Hz - HFC-410A *LC402* LC402 Rev.: November 18, 2016 Table of Contents TMW Water-To-Water Series Unit Feature 3 Selection Procedure

More information

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h ooling apacity: 24,000-60,000 BTU/h High-Efficiency, omfortnet -ompatible, Split-System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI

More information

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h GP13M Packaged Air onditioner R-410A, 13 SEER ooling apacity: 36,000-56,000 BTU/h 3, 4, & 5 Tons Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor

More information

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

DUAL CAPACITY HEATING COOLING HOT WATER. AFFORDABLE RENEWABLE CLEAN MAGNOLIA PLUS SERIES

DUAL CAPACITY HEATING COOLING HOT WATER.   AFFORDABLE RENEWABLE CLEAN MAGNOLIA PLUS SERIES S P E C I F I C A T I O N C A T A L O DUAL CAPACITY HEATIN COOLIN HOT WATER www.geostar-geo.com AFFORDABLE RENEWABLE CLEAN MANOLIA PLUS SERIES MANOLIA PLUS SPECIFICATION UIDE Table of Contents Model Nomenclature...............................................................

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical

More information

DZ11S Commercial & 10-Ton, Three-Phase

DZ11S Commercial & 10-Ton, Three-Phase DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 Expanded Heating Data... 12 AHRI

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h DSX18 ooling apacity: 34,000-56,000 BTU/h Split System Air onditioner up to 18 SEER Standard Features R-410A chlorine-free refrigerant Two-Stage opeland UltraTech scroll compressor High-density foam compressor

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications CDI series Model TW Residential to Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options and Control Options Standard Features White Pre-Painted Sheet

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

50RDS, 50RHS, 50RVS PREMIUM EFFICIENCY WATER SOURCE HEAT PUMPS

50RDS, 50RHS, 50RVS PREMIUM EFFICIENCY WATER SOURCE HEAT PUMPS 50-5 T 50D, 50H, 50V EIU EIIEY WTE UE HET U / 2 to 6 I T EE DT DIEI IT opyright 2002 arrier orporation yracuse, ew York 322 orm 50-5 eplaces: 50-3 rinted in U... 6-02 atalog o. 55-0009 Date: upersedes:

More information

GPH13M. 13 SEER / R-410A 2 to 5 Tons

GPH13M. 13 SEER / R-410A 2 to 5 Tons ooling apacity: 24,000-56,000 BTU/h Heating apacity: 23,000-55,500 BTU/h GPH13M Packaged Heat Pump 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve

More information

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...

More information

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H HIGH-EFFIIENY PRODUT SPEIFIATIONS SPLIT SYSTEM AIR ONDITIONER The Goodman Air onditioner uses the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone

More information

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h DP14HM ommercial ooling apacity: 34,400-58,000 BTU/h Heating apacity: 33,00-57,000 BTU/h 3-5 TON THREE-PHASE PAKAGED HEAT MPS 14 SEER ontents Nomenclature... Product Specifications...3 Expanded ooling

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TEHNIAL INFOMATION MANUAL SSZ 16 SEE Split System Heat Pumps Models listed on page 3 efer to Service Manual S6200005 for installation, operation, and troubleshooting information. All safety information

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or

More information

700A11. Geothermal Heat Pump - 50Hz kw (variable speed) Submittal Data English Language/SI Units SD2705AN 01/15

700A11. Geothermal Heat Pump - 50Hz kw (variable speed) Submittal Data English Language/SI Units SD2705AN 01/15 700A eothermal Heat Pump - 50Hz 009-05 (variable speed) Submittal Data English Language/SI Units SD705AN 0/5 ontractor: 7 Series 700A 009-05 50Hz Model Nomenclature - 4 5-7 8 9 0 4 5 N VK V 0 * 6 L 0 6

More information

SPECIFICATION CATALOG

SPECIFICATION CATALOG SPECIFICATION CATALO EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE CLEAN CYPESS SEIES Table of Contents The Cypress........................................................................... 4 Model Nomenclature....................................................................

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model

More information

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating. EMIP60 ISO EM Series, Inch Pounds 60 Hz EM007360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: 81402 Changed EM170/240HZ dwg 31103 Changed HZ dwg to

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information