ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

Size: px
Start display at page:

Download "ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14"

Transcription

1 ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump Submittal Data English Language/IP Units SD1022AGA 05/14

2 Model Nomenclature GB V 048 T L C A N 15 A 16 N A SS 23 * Model Type GB Aston Compact Cabinet Configuration V Vertical H - Horizontal Unit Capacity (MBTUH) Single Speed 009, 012, 015, 018, 024, 0 036, 042, 048, 060, 070 Dual-Capacity 026, 038, 049, 064, 072 Discharge Configuration T Top (Vertical) E End (Horizontal) S Side (Horizontal) Return Air Configuration L Left R Right Voltage 0 8-2/60/ /60/1 ( ) 3 8-2/60/3 ( ) 4 460/60/3 ( ) 5 575/60/3 (PSC Only ) Refrigeration Option 0 None 2 HWG Only w/o Pump (Vertical ) G Hot Gas Bypass ( ) R Hot Gas Reheat ( ) B Hot Gas Bypass w/hot Gas Reheat ( ) Blower Options 0 PSC Blower (Single Speed Only) 1 Variable Speed ECM Blower ( ) 2 High Static Variable Speed ECM Blower (036, 038, 042, 048, 049) 3 High Static PSC Blower ( ) 4 5-Speed ECM Blower ( ) Water Coil Option C Copper D Insulated Copper N CuproNickel P Insulated CuproNickel Note: Phase Guard Only Available on 8-2/60/3, 460/60/3, and 575/60/3 Vintage * - Factory Use Only Non-Standard Options SS Standard Drain Pan Option 0 Composite, No Secondary Connection 1 Composite, Secondary Connection 2 Stainless Steel, No Secondary Connection 3 Stainless Steel, Secondary Connection Air Coil Option 3 Standard 4 AlumiSeal TM Filter Option A MERV 4 B MERV 13 Cabinet Option 0 Unpainted Cabinet, Filter Rail 1 Painted Cabinet, Filter Rail 2 Unpainted Cabinet, 4-Sided Filter Rack 3 Painted Cabinet, 4-Sided Filter Rack Electrical Option N None A IntelliStart Only E IntelliStart and Disconnect P Phase Guard, No Disconnect B Phase Guard, Disconnect D No Phase Guard, Disconnect Control Option A Aurora TM Base Control (ABC) 4 FX10 std. No Communications 5 FX10 w/ Open N2 Com Card 6 FX10 w/ LonWorks Com Card 7 FX10 w/ BacNet Com Card Water Control Option N None R Water Flow Regulator V 2-Way Valve B 2-Way Valve w/ Water Flow Regulator Sound Kit Option A None B Sound Kit Rev.: 24 April 14D SD1022AGA 05/14 2 Page of

3 AHRI Data PSC Motors ARI/ASHRAE/ISO English (IP) Units Model Capacity Modulation Flow Rate Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Cooling Brine Heating Cooling Heating Full Load 77 EWT 68 EWT 59 EWT Part Load 68 Cooling EWT 86 Heating Brine Full Load 32 Part Load 41 gpm cfm Capacity EER Capacity Capacity EER Capacity Capacity EER Capacity Btu/h Btuh/W Btu/h Btu/h Btuh/W Btu/h Btu/h Btuh/W Btu/h 009 Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , , , Cooling capacities based upon 80.6 DB, 66.2 WB entering air temperature Heating capacities based upon 68 DB, 59 WB entering air temperature All ratings based upon 8V operation Variable Speed ECM and 5-Speed ECM Motors AHRI/ASHRAE/ISO English (IP) Units Model Capacity Modulation Flow Rate Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Cooling Brine Heating Cooling Heating Full Load 77 EWT 68 EWT 59 EWT Part Load 68 Cooling EWT 86 Heating Brine Full Load 32 Part Load 41 gpm cfm Capacity EER Capacity Capacity EER Capacity Capacity EER Capacity Btu/h Btuh/W Btu/h Btu/h Btuh/W Btu/h Btu/h Btuh/W Btu/h 015 Single , , , , , , Single , , , , , , Single , , , , , , Single , , , , ,0 21.9, Single , , , , , , Single , , , , , , Single , , , , ,0.1 35, Single , , , , , , Single , , , , , , Full , , , , , ,0 4.3 Part 7.0 7, , , , , ,0 4.8 Full , , , , , , Part ,0.3 29, , , , , Full , , , , , ,0 4.0 Part , , , ,0 4.7, , Full , , , , , , Part , , , ,0 5.0, , Full , , , , , , Part , , , , , , Cooling capacities based upon 80.6 DB, 66.2 WB entering air temperature Heating capacities based upon 68 DB, 59 WB entering air temperature All ratings based upon 8V operation SD1022AGA 05/14 3 Page of

4 Vertical Dimensional Data Standard filter rails for open return applications Field installed duct flange Deluxe filter rack for ductable return applications A N R S A N Air coil Q Q ACCESS PANEL B P G F AIR COIL SIDE 4 3 FRONT 1.4 in (3.5 cm) Top View - Right Return M M AIR COIL SIDE FRONT 1.4 in (3.5 cm) Top View - Left Return 4 3 P G F B 2' (61 cm) Alternate Service Access 2' (61 cm) Service Access Left Return (Right Return opposite side) Isometric View - Left Return U T W Air coil Air coil ACCESS PANEL ACCESS PANEL V C H E D 1.6 in (4.1 cm) Condensate 3/4 in PVC glue socket 1.6 in (4.1 cm) L J supply 1 in (25.4 mm) knockout Low voltage 1/2" (12.7 mm) knockout L K 8 7 Condensate 3/4 in PVC glue socket 1.6 in (4.1 cm) E H D C 1.6 in (4.1 cm) J L 6 8 ACCESS PANEL 8 7 K L Front View - Right Return Front View - Left Return Right View - Right Return Left View - Left Return SD1022AGA 05/14 4 Page of

5 Vertical Dimensional Data cont. Vertical Models Electrical Knockouts Water Connections Overall Cabinet J K L 1/2 in. 1/2 in. A B C D E F G H Loop Knockout 1 in. cond cond cond Width Depth Height* In Out HWG In HWG Out Condensate Water FPT HWG Provisions Low Voltage Low Voltage in N/A N/A /2 in. N/A cm N/A N/A mm N/A in /4 in cm mm 22.2 mm in /4 in cm mm 22.2 mm in in cm mm 22.2 mm in in cm mm 22.2 mm Supply in in cm mm 22.2 mm Discharge Connection duct flange installed (±0.10 in) **Return Connection using deluxe fi lter rack (±0.10 in) Vertical Models M N P Q R S T U V W Filter Rack Return Supply Width Supply Depth Return Depth Width Height in cm in cm in cm in cm in cm in cm Condensate is 3/4 in. PVC female glue socket and is switchable from side to front. *Discharge flange is field installed and extends 1 in. (25.4 mm) from top of cabinet. **Vertical units shipped with standard 2 in. (field adjustable to 1 in.) open application filter rack extending 2.2 in. from unit and is not suitable for duct connection, for ductable return connection applications, order the deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack which extends 3.25 in. from the unit and is suitable for duct connections. Vertical Disconnect When using disconnect, do not use dimension L from the standard vertical dimensional data. Use dimension LL from the vertical disconnect dimensional data. Vertical Models LL [45.2] [36.3] [38.9] [36.3] [36.3] [36.3] External Dimensions in inches [cm] Supply 1.8 in. [4.6 cm] Disconnect Location LL Alternative Location Disconnect Located on this Side for a Right Return Vertical Shown in Left Return Configuration SD1022AGA 05/14 5 Page of

6 Horizontal Dimensional Data Right Return Standard filter rails 1 in. [2.5 cm] knockout 0.5 in. [1.3 cm] knockout Front K 1.7 in. [5.3 cm] CP 1.7 in. [5.3 cm] Standard filter rails Front Left Return AP J E AP CMP A RR Front View D AP CMP ' (61 cm) Service Access J 2' (61 cm) Service Access Condensate "X" PVC size End Discharge Deluxe filter rack option shown 2.3 in. [5.8 cm] N P H FILTER RACK AIR COIL SIDE Right Return End Discharge Side Discharge E D CP AP LR Front View Side Discharge Left Return End Discharge Condensate "X" PVC size End Discharge Deluxe filter rack option shown P N BLOWER L OUTLET Legend M C AP = Alternate Service Panel C M L BP CP = Blower Service Panel = Control Access Panel BLOWER OUTLET 2.1 in. [5.3 cm] CMP = Compressor Service Panel 2.1 in. [5.3 cm] A A K 0.5 in. [1.3 cm] knockout 1 in. [2.5 cm] knockout FILTER RACK AIR COIL SIDE 2.3 in. [5.8 cm] H P N 1.5 in. [3.8 cm] 1.5 in. [3.8 cm] N P BP L M BLOWER OUTLET Right Return Side Discharge AP CMP K 0.5 in. [1.3 cm] J knockout Front Front 1 in. [2.5 cm] J knockout 0.5 in. [1.3 cm] K knockout AP CMP Left Return Side Discharge BLOWER OUTLET M L BP Air Coil C Q S T T S Q FILTER RACK CONNECTION R Deluxe filter rack option (shown) C R FILTER RACK CONNECTION Air Coil Front Front B Right Return Side View B Left Return Side View SD1022AGA 05/14 6 Page of

7 Horizontal Dimensional Data cont. Water Connections Electrical Knockouts Overall Cabinet Horizontal J K Models A B C D E H Loop 1/2 in. cond 1 in. cond Width Depth Height* In Out Condensate Water FPT Low Voltage Supply in /2 in cm mm in /4 in cm mm in /4 in cm mm in in cm mm in in cm mm in in cm mm in in cm mm Discharge Connection Return Connection Horizontal duct fl ange installed (±0.10 in.) using deluxe fi lter rack option (±0.10 in.) PVC Size Models L M N P Q R S T X Supply Width Supply Depth Return Depth Return Height in /4 cm in /4 cm in /4 cm in /4 cm in /4 cm in /4 cm in / cm Horizontal units shipped with standard 2 in. (field adjustable to 1 in.) open application filter rack extending 2.2 in. from unit and is not suitable for duct connection, for ductable return connection applications, order the deluxe 2 in. (field adjustable to 1 in.) filter rail/filter rack which extends 3.25 in. from the unit and is suitable for duct connections. Horizontal Disconnect When using disconnect, do not use dimension K from the standard horizontal dimensional data. Use dimension KK from the horizontal disconnect dimensional data. Horizontal Models KK [.8] [23.4] [23.4] [28.4] [25.9] [28.4] [25.9] Dimensions in inches [cm] Disconnect Located on this Side for a Left Return 2.1 in. [5.3 cm] Disconnect Location KK Supply Horizontal Shown in Right Return Configuration SD1022AGA 05/14 7 Page of

8 Hanger Bracket Locations H Right Left B D E Compressor Section Air Handler Section F G C E D Compressor Section Air Handler Section G F A H 3/8 Threaded Rod (not supplied) Vibration Isolator Washer Bolt and Lockwasher Hex Nuts (not supplied) NOTE: Model sizes will be shipped with six (6) hanger brackets. Only five (5) hanger brackets will be used on the unit. See the above illustration for the fifth hanger bracket location. All other models will use four (4) hanger brackets. Hanger Bracket Dimensions Single Speed Dual Capacity Model Hanger Kit Part Number Unit Hanger Dimensions A B C H n/a in. 99S0A04 cm n/a in n/a 99S0A04 cm n/a in n/a 99S0A04 cm n/a in n/a 99S0A04 cm n/a in n/a 99S0A04 cm n/a in n/a 99S0A04 cm n/a in S0A03 cm in n/a 99S0A04 cm n/a in n/a 99S0A03 cm n/a in n/a 99S0A04 cm n/a in n/a 99S0A04 cm n/a in S0A03 cm Weight Distribution Single Speed Model Vertical Weight Horizontal Weight Horizontal Weight Distribution Front Back D E F G [78] [80] [15] [] [15] [] [78] [80] [15] [] [15] [] [95] [100] [29] [18] [32] [16] [95] [100] [29] [18] [32] [16] [127] [134] [34] [31] [34] [13] [129] [134] [34] [31] [34] [13] [136] [138] [39] [36] [39] [18] [166] [170] [52] [43] [34] [27] [168] [172] [54] [45] [36] [29] [186] [191] [54] [] [43] [36] [2] [6] [61] [54] [45] [39] [127] [134] [34] [31] [34] [13] [163] [170] [52] [43] [34] [27] [168] [172] [54] [45] [36] [29] [186] [191] [54] [] [43] [36] [2] [6] [61] [54] [45] [39] Weights are listed in lbs. [kg]. Dual Capacity SD1022AGA 05/14 8 Page of

9 Physical Data Model Single Speed Compressor (1 each) Rotary Scroll Factory Charge R-410A, oz [kg] Vertical 29 [0.82] 36 [1.02] 38 [1.08] 48 [1.36] 56 [1.59] 68 [1.93] 84 [2.38] 86 [2.44] 92 [2.61] 100 [2.83] 128 [3.63] Factory Charge R-410A, oz [kg] Horizontal 29 [0.82] 36 [1.02] 42 [1.19] 42 [1.19] 54 [1.53] 64 [1.81] 78 [2.21] 84 [2.38] 92 [2.61] 84 [2.38] 118 [3.35] Blower Motor & Blower Blower Motor Type/Speeds Blower Motor, hp [W] Oversized PSC Blower Motor, hp [W] Blower Wheel Size (Dia x W), in. [mm] Oversized Blower Wheel Size (Dia x W), in. [mm] VS ECM Not Available Variable Speed ECM 5-Spd ECM Not Available 5-Speed ECM PSC PSC 4 Speeds PSC - 3 Speeds VS ECM Not Available 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] 5-Spd ECM Not Available 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] 1 [746] 1 [746] PSC 1/10 [75] 1/10 [75] 1/6 [134] 1/6 [134] 1/5 [149] 1/3 [249] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] VS ECM Not Available 1 [746] 1 [746] Not Available PSC Not Available 1/3 [249] 1/2 [373] 1/2 [373] 3/4 [560] 3/4 [560] N/A N/A VS ECM 5-Spd ECM PSC VS ECM PSC Not Available Not Available 6 x 8 [152 x 3] 6 x 8 [152 x 3] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] Not Available 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] Not Available 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 10 x 10 [254 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] Not Available Not Available Coax and Water Piping Water Connections Size - FPT - in. [mm] 1/2 [12.7] 1/2 [12.7] 3/4 [19.05] 3/4 [19.05] 3/4 [19.05] 3/4 [19.05] 1 [25.4] 1 [25.4] 1 [25.4] 1 [25.4] 1 [25.4] HWG Connection Size - Female Sweat I.D. - in [mm] (Vertical Only) Not Available 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] Coax and Piping Water Volume - gal [l] 0.26 [0.98] 0.3 [1.12] 0.4 [1.49] 0.4 [1.49] 0.4 [1.49] 0.75 [2.83] 0.9 [3.41] 0.9 [3.41] 1.25 [4.72] 1.5 [5.68] 1.5 [5.68] Vertical Air Coil Dimensions (H x W), in. [mm] 12 x x x 19 x 24 x 28 x 28 x x 25 [ x 25 [ x 25 [ x 25 [914 [5 x 6] [6 x 6] [483 x 8] [483 x 8] [610x 8] [711 x 8] [711 x 635] x 635] x 635] x 635] x 635] Air Coil Total Face Area, ft 2 [m 2 ] 1.3 [0.121] 1.8 [0.167] 2.6 [0.242] 2.6 [0.242] 3.3 [0.7] 3.9 [0.362] 4.9 [0.455] 5.6 [0.5] 5.6 [0.5] 6.3 [0.585] 6.3 [0.585] Air Coil Tube Size, in [mm] 5/16 [7.9] 3/8 [9.5] 5/16 [7.9] 5/16 [7.9] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Number of rows Filter Standard - 1 in. [25mm] Pleated MERV 4 Throwaway, in [mm] Filter Standard - 2 in. [51mm] Pleated MERV 13 Throwaway, in [mm] Horizontal 1-16 x [6 x 8] 1-16 x [6 x 8] 1-16 x 18 [6 x 457] 1-16 x 18 [6 x 457] 1-24 x 24 [610 x 610] 1-24 x 24 [610 x 610] 1-24 x 24 [610 x 610] 1-24 x 24 [610 x 610] 28 x 24 [712 x 610] 28 x 24 [712 x 610] 28 x 24 [712 x 610] 28 x 24 [712 x 610] 28 x [712 x 762] 28 x [712 x 762] 32 x [813 x 762] 32 x [813 x 762] 32 x [813 x 762] 32 x [813 x 762] x 36 [762 x 914] x 36 [762 x 914] x 36 [762 x 914] x 36 [762 x 914] Air Coil Dimensions (H x W), in. [mm] 12 x 16 [5 x 6] 16 x 16 [6 x 6] 18 x 21 [457 x 533] 18 x 21 [457 x 533] 18 x 27 [457 x 686] 18 x [457 x 762] x 35 [8 x 889] x [8 x 1016] x [8 x 1016] x 45 [8 x 1143] x 45 [8 x 1143] Air Coil Total Face Area, ft 2 [m 2 ] 1.3 [0.121] 1.8 [0.167] 2.6 [0.242] 2.6 [0.242] 3.4 [0.316] 3.8 [0.353] 4.9 [0.455] 5.6 [0.5] 5.6 [0.5] 6.3 [0.585] 6.3 [0.585] Air Coil Tube Size, in. [mm] 5/16 [7.9] 3/8 [9.5] 5/16 [7.9] 5/16 [7.9] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Number of rows Filter Standard - 1 in. [25mm] Pleated MERV 4 Throwaway, in. [mm] 1-16 x 18 [6 x 8] 1-16 x 18 [6 x 8] 2-18 x 14 [457 x 356] 2-18 x 14 [457 x 356] 1-18 x 18 [457 x 457] 1-18 x 14 [457 x 356] 1-18 x 18 [457 x 457] 1-18 x 14 [457 x 356] 2-18 x [457 x 8] 1 - x [8 x 8] 1 - x 22 [8 x 559] 1 - x [8 x 8] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] Filter Standard - 2 in. [51mm] Pleated MERV 13 Throwaway, in. [mm] 1-16 x 18 [6 x 8] 1-16 x 18 [6 x 8] 1-18 x 29 [457 x 737] 1-18 x 29 [457 x 737] 1-18 x 32 [457 x 813] 1-18 x 32 [457 x 813] 1 - x 37 [686 x 9] 1 - x [8 x 8] 1 - x 22 [8 x 559] 1 - x [8 x 8] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 4/11/14 SD1022AGA 05/14 9 Page of

10 Physical Data cont. Model Dual Capacity Compressor (1 each) Copeland 2-speed Scroll, UltraTech Factory Charge R410-A, oz [kg] Vertical 56 [1.59] 78 [2.21] 93 [2.64] 104 [2.95] 128 [3.63] Factory Charge R410-A, oz [kg] Horizontal 52 [1.47] 74 [2.10] 93 [2.64] 118 [3.35] 138 [3.91] Variable Speed ECM Blower Motor and Blower Blower Motor Type/Speeds Variable Speed ECM 5-Speed ECM VS ECM 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] Blower Motor- hp [W] 5-Spd ECM 1/2 [373] 1/2 [373] 1 [746] 1 [746] 1 [746] Oversized Blower Motor- hp [W] VS ECM not available 1 [746] 1 [746] Not Available Not Available Blower Wheel Size (Dia x W), in. [mm] Blower Wheel Size (Dia x W), in. [mm] VS ECM 5-Spd ECM 9 x 7 [229 x 178] 9 x 7 [229 x 178] Oversized Blower Wheel Size (Dia x W), in. [mm] VS ECM Not Available 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] Not Available 11 x 10 [279 x 254] 11 x 10 [279 x 254] Not Available Coax and Water Piping Water Connections Size - FPT - in [mm] 3/4 [19.05] 1 [25.4] 1 [25.4] 1 [25.4] 1 [25.4] HWG Connection Size - Female Sweat I.D. - in. [mm] (Vertical Only) 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] 1/2 [12.7] Coax and Piping Water Volume - gal [l] 0.7 [2.6] 1.3 [4.9] 1.6 [6.1] 1.6 [6.1] 2.3 [8.7] Vertical Air Coil Dimensions (H x W), in. [mm] 24 x [610 x 8] 28 x 25 [711 x 635] 32 x 25 [813 x 635] 36 x 25 [914 x 635] 36 x 25 [914 x 635] Air Coil Total Face Area, ft 2 [m 2 ] 3.3 [0.7] 4.9 [0.451] 5.6 [0.5] 6.3 [0.585] 6.3 [0.585] Air Coil Tube Size, in. [mm] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Number of rows Filter Standard - 1 in. [25mm] Pleated MERV 4 Throwaway, in. [mm] Filter Standard - 2 in. [51mm] Pleated MERV 13 Throwaway, in. [mm] Horizontal Air Coil Dimensions (H x W), in. [mm] 28 x 24 [712 x 610] 28 x 24 [712 x 610] 18 x 27 [457 x 686] 28 x [711 x 762] 28 x [711 x 762] x 35 [8 x 889] 32 x [813 x 762] 32 x [813 x 762] x [8 x 1016] 36 x [914 x 762] x 36 [762 x 914] x 45 [8 x 1143] x 36 [762 x 914] x 36 [762 x 914] x 45 [8 x 1143] Air Coil Total Face Area, ft 2 [m 2 ] 3.4 [0.316] 4.9 [0.451] 5.6 [0.5] 6.3 [0.585] 6.3 [0.585] Air Coil Tube Size, in. [mm] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Number of rows Filter Standard - 1 in. [25mm] Pleated MERV 4 Throwaway, in. [mm] Filter Standard - 2 in. [51mm] Pleated MERV 13 Throwaway, in. [mm] 1-18 x 18 [457 x 457] 1-18 x 14 [457 x 356] 1-18 x 32 [457 x 813] 2-18 x [457 x 8] 1 - x 37 [8 x 9] 1 - x 22 [8 x 559] 1 - x [8 x 8] 1 - x [8 x 8] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 1 - x 25 [8 x 635] 1 - x 22 [8 x 559] 4/11/14 SD1022AGA 05/14 10 Page of

11 Electrical Availability PSC Static Single Speed Models Dual Capacity Models Voltage Option /60/1 8-2/60/1 w/intellistart 265/60/1 Standard 8-2/60/3 (also w/intellistart) 460/60/3 (also w/intellistart) 575/60/3 8-2/60/1 (also w/intellistart) 265/60/1 8-2/60/3 (also w/intellistart) High 460/60/3 (also w/intellistart) 575/60/3 1/2/13 5-Speed ECM Static Single Speed Models Dual Capacity Models Voltage Option /60/1 8-2/60/1 w/intellistart 265/60/1 Standard 8-2/60/3 (also w/intellistart) 460/60/3 (also w/intellistart) 575/60/3 1/2/13 Variable Speed ECM Static Single Speed Models Dual Capacity Models Voltage Option /60/1 8-2/60/1 w/intellistart 265/60/1 Standard 8-2/60/3 (also w/intellistart) 460/60/3 (also w/intellistart) 575/60/3 8-2/60/1 265/60/1 8-2/60/3 (also w/intellistart) High 460/60/3 (also w/intellistart) 575/60/3 1/2/13 SD1022AGA 05/14 11 Page of

12 Electrical Data PSC Motor Single Speed Model Rated Voltage Voltage Min/Max Compressor MCC RLA LRA LRA** Blower Motor FLA Total Unit FLA Min Circ Amp Max Fuse/ HACR Breaker /60/1 187/ n/a /15 265/60/1 238/ n/a / /60/1 187/ n/a /15 265/60/1 238/ n/a / /60/1 187/ n/a /60/1 238/ n/a / /60/1 187/ /60/1 238/ n/a /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ * 265/60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ * 265/60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ * 265/60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /15 575/60/3 517/ n/a /15 8-2/60/1 187/ * 8-2/60/3 187/ /60/3 414/ /60/3 517/ n/a /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ n/a /15 8-2/60/1 187/ * 8-2/60/3 187/ /60/3 414/ /60/3 517/ n/a /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ n/a /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /60/3 517/ n/a /06/13 HACR circuit breaker in USA only *With optional High-static PSC motor **With optional IntelliStart SD1022AGA 05/14 12 Page of

13 Electrical Data cont. 5-Speed ECM Motor Dual Capacity Single Speed Model Rated Voltage Voltage Min/Max Compressor MCC RLA LRA LRA** Blower Motor FLA Total Unit FLA Min Circ Amp Max Fuse/ HACR Breaker 8-2/60/1 187/ n/a /60/1 238/ n/a /15 8-2/60/1 187/ /60/1 238/ n/a /60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ HACR circuit breaker in USA only **With optional IntelliStart 5/21/13 SD1022AGA 05/14 13 Page of

14 Electrical Data cont. Variable Speed ECM Motor Single Speed Dual Capacity Model Rated Voltage Voltage Min/Max Compressor MCC RLA LRA LRA** CAUTION: When installing a unit with a variable speed ECM blower motor in 460/60/3 voltage, a neutral wire is required to allow proper unit operation. Blower Motor FLA Total Unit FLA Min Circ Amp Max Fuse/ HACR Breaker /60/1 187/ n/a /60/1 238/ n/a /60/1 187/ /60/1 238/ n/a /60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ * 265/60/1 238/ n/a /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ * 8-2/60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ * 8-2/60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /15 8-2/60/1 187/ /60/1 238/ n/a /60/3 187/ /60/3 414/ /60/1 187/ * 265/60/1 238/ n/a /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ * 8-2/60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ /60/1 187/ /60/3 187/ /60/3 414/ HACR circuit breaker in USA only 5/21/13 *With optional 1 HP variable speed ECM motor **With optional IntelliStart SD1022AGA 05/14 14 Page of

15 Blower Performance Data Standard PSC Motor Blower Blower Motor Airflow (cfm) at External Static Pressure (in. wg) Model Spd Size HP H MH x 8 1/10 ML* L H MH* x 8 1/10 ML L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 9 x 7 1/ L H M 10 x 10 1/ L H M 10 x 10 1/ L H M 10 x 10 1/ L H M 11 x L H M 11 x L Optional High Static PSC Motor Blower Blower Motor Airflow (cfm) at External Static Pressure (in. wg) Model Spd Size HP H M 9 x 7 1/ L H M 9 x 7 1/ L H M 10 x 10 1/ L H M 10 x 10 3/ L H M 10 x 10 3/ L Factory settings are in Bold Air flow values are with dry coil and 1 in. MERV 4. For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airfl ow [cfm] / Face Area [sq ft]). Then for velocities of 0 fpm reduce the static capability by 0.03 in. wg, 0 fpm by 0.08 in. wg, 0 fpm by 0.12in. wg. and 0 fpm by 0.16 in. wg. * Denotes setting for 265 V operation. Setting Blower Speed - PSC CAUTION: Disconnect all power before performing this operation. BLOWER SPEED WIRE HIGH MEDIUM LOW PSC BLOWER MOTOR BODY SD1022AGA 05/14 15 Page of

16 Blower Performance Data cont. 5-Speed ECM - Single Speed Model Motor Spd Motor Tap T Stat Cnct. Blower Size Motor HP Airflow (cfm) at External Static Pressure (in. wg) High 5 Med High 4 W Med 3 9 x 7 1/ Med Low 2 Y Low 1 G High Med High 4 W Med 3 9 x 7 1/ Med Low 2 Y Low 1 G High 5 W Med High 4 Y Med 3 9 x 7 1/ Med Low 2 G Low High Med High 4 W Med 3 Y1 9 x 7 1/ Med Low Low 1 G High 5 W Med High 4 Y Med 3 11 x 10 1/ Med Low Low 1 G High Med High 4 W Med 3 11 x Med Low 2 Y Low 1 G High Med High 4 W Med 3 Y1 11 x Med Low Low 1 G High 5 W Med High 4 Y Med 3 11 x Med Low Low 1 G High 5 W Med High 4 Y Med 3 11 x Med Low Low 1 G Factory settings are in Bold Air fl ow values are with dry coil and standard 1 in. fi lter 11//12 About 5-Speed ECM Constant Torque Motors The 5-speed ECM is a Constant Torque ECM motor and delivers air flow similar to a PSC but operates as efficiently as a variable speed ECM motor. Because it is an ECM motor, the 5-speed ECM can ramp slowly up or down like the variable speed ECM motor. There are 5 possible speed taps available on the 5-speed ECM motor with #1 being the lowest airflow and #5 being the highest airflow. These speed selections are preset at the time of manufacture and are easily changed in the field if necessary. If more than one tap are energized at the same time, built in logic gives precedence to the highest tap number and allows air flow to change with G, Y1, Y2 and W signals. Each of those 5 speeds has a specific Torque value programmed into the motor for each speed selection. As static pressure increases, airflow decreases resulting in less torque on the rotor. The motor responds only to changes in torque and adjusts its speed accordingly. The 5-speed ECM motor is powered by line voltage but the motor speed is energized by 24VAC. 5-Speed ECM Benefits: - High efficiency - Soft start - 5 speeds with up to 4 speeds on-line - Built in logic allows air flow to change with G, Y1, Y2 and W signals - Super efficient low airflow continuous blower setting (G) SD1022AGA 05/14 16 Page of

17 Blower Performance Data cont. 5-Speed ECM - Dual Capacity Model 026 Motor Speed Motor Tap T stat Cnct. Blower Size Motor HP Airflow (cfm) at External Static Pressure (in. wg) High 5 W Med High 4 Y Med 3 9 x 7 1/ Med Low 2 Y Low 1 G High 5 W Med High 4 Y Med 3 Y1 11 x 10 1/ Med Low Low 1 G High 5 W Med High Med 3 Y2 11 x Med Low 2 Y Low 1 G High 5 W Med High 4 Y Med 3 11 x Med Low 2 Y Low 1 G High 5 W Med High 4 Y Med 3 11 x Med Low 2 Y Low 1 G Factory speed settings are in Bold Air fl ow values are with dry coil and standard fi lter For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airfl ow [cfm] / Face Area [sq ft]). Then for velocities of 0 fpm reduce the static capability by 0.03 in. wg, 0 fpm by 0.08 in. wg, 0 fpm by 0.12in. wg., and 0 fpm by 0.16 in. wg. Highest setting is for auxiliary heat (W) and lowest setting is for constant blower (G). The Y1 and Y2 settings must be between the G and W settings. Setting Blower Speed - 5-Speed ECM 5-speed ECM blower motors have five (5) speeds of which three (3) are selectable on single speed and four (4) are selectable on dual capacity. CAUTION: Disconnect all power before performing this operation. 5-Speed ECM Motor Connections - Single Speed 5-Speed ECM Motor Connections - Dual Capacity C - Black L - Orange G - Green C High Voltage Connections 3/16 in. L G N N - Brown C - Black L - Orange G - Green C High Voltage Connections 3/16 in. L G N N - Brown G - Blue Y1 - Red Low Voltage Connections 1/4 in. AUX - Gray G - Blue Y1 - Red Low Voltage Connections 1/4 in. AUX - Gray Y2 - Tan SD1022AGA 05/14 17 Page of

18 Blower Performance Data cont. Variable Speed ECM Motor Single Speed Model Max ESP Blower Size Motor hp x 7 1/ x 7 1/ x 7 1/ x 7 1/ x 10 1/2 036 w/1hp* x x 10 1/2 042 w/1hp* x x 10 1/2 048 w/1hp* x x x 10 1 Dual Capacity Model Max ESP Blower Size Motor hp x 7 1/ x 10 1/2 038 w/1hp* x x 10 1/2 049 w/1hp* x x 10 1 Airflow DIP Switch Settings L M H L M H L M H L M H L M H L M H L M H L M H L M H L M H L M H L M H Air Flow DIP Switch Settings L M H L M H L M H L M H L M H L M H x 10 1 L M H Factory settings are at recommended L-M-H DIP switch locations M-H settings MUST be located within boldface cfm range Lowest and Highest DIP switch settings are assumed to be L and H respectively cfm is controlled within ±5% up to the maximum ESP Max ESP includes allowance for wet coil and 1 in. MERV 4 SD1022AGA 05/14 18 Page of

19 Operating Limits Operating Limits Cooling Heating () ( C) () ( C) Air Limits Min. Ambient Air Rated Ambient Air Max. Ambient Air Min. Entering Air Rated Entering Air db/wb 80.6/ / Max. Entering Air db/wb 110/83 43/ Water Limits Min. Entering Water Normal Entering Water Max. Entering Water NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependent upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation. Legend ABBREVIATIONS AND DEFINITIONS: cfm = airflow, cubic feet/minute EWT = entering water temperature, Fahrenheit gpm = water flow in gallons/minute WPD = water pressure drop, psi and feet of water EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) HC = air heating capacity, TC = total cooling capacity, SC = sensible cooling capacity, = total power unit input, kilowatts HR = total heat of rejection, HE = total heat of extraction, HWC = hot water generator capacity, EER = Energy Efficient Ratio = BTU output/watt input = Coefficient of Performance = Btu output/btu input LWT = leaving water temperature, LAT = leaving air temperature, TH = total heating capacity, LC = latent cooling capacity, S/T = sensible to total cooling ratio SD1022AGA 05/14 19 Page of

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET AFFINITY COMPACT COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE AND DUAL CAPACITY MODELS: YKS009-0 (.75 THRU 6 NOMINAL TONS) YKT026-072 (2 THRU 6 NOMINAL

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZA 05/14 ARBOR BASE SERIES OMMERIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD0AZA 05/4 Model Nomenclature -5 6 7 8 9 0 4 5 6 7 8 9 0- Z B V 06 T L 0 0 0 A N A N A 0 SS * Model Type Z Arbor Operation

More information

ComPACT. Commercial kw Water Source/Geothermal Heat Pump - 50Hz. Submittal Data English Language/IP Units SD1025AN 07/12

ComPACT. Commercial kw Water Source/Geothermal Heat Pump - 50Hz. Submittal Data English Language/IP Units SD1025AN 07/12 ompat ommercial 005-017 Water Source/eothermal Heat Pump - 50Hz Submittal Data English Language/IP Units SD1025AN 07/12 Model Nomenclature 1-3 NBK 4 V 5-7 009 8 T 9 L 10 7 11 0 12 4 13 14 A 15 N 16 A 17

More information

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16

ARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16 ABO BASE SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZB 03/16 Model Nomenclature 1 2 2 3-5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20-21 22 Z B V 036 T L 0 0 0 A N A N

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET LX SERIES EOTHERMAL HEAT PUMPS DUAL APAITY MODELS: YLF026-072 (2 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change

More information

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18

ARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18 ABO OMPAT SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZ 08/18 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21-22 23 Z B V 036 T L 0 0 0 A N A

More information

Aston Series GEOTHERMAL HEAT PUMPS 1 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2500AG 09/15

Aston Series GEOTHERMAL HEAT PUMPS 1 TO 6 TONS. Submittal Data English Language IP/Metric Units SD2500AG 09/15 EOTHEMAL HEAT PUMPS TO 6 TONS Submittal Data English Language IP/Metric Units SD500A 09/5 ontractor: Model Nomenclature - 3 4 5-7 8 9 0 3 4 0 * 036 T L 0 5 0 6 A 7 0 Model Type 0 Aston Water-to-Air Type

More information

500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2500AN 11/17

500A11. Geothermal heat pump 1-6 ton (single speed) 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2500AN 11/17 500A eothermal heat pump -6 ton (single speed) -6 ton (dual capacity) Submittal Data English Language/IP Units SD500AN /7 ontractor: Model Nomenclature 4-6 7 8 9 0 4 N D V 049 * T L 0 5 A 6 N ompressor

More information

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17

500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 500O11 Outdoor Split eothermal Heat Pump 2-6 ton (dual capacity) Submittal Data English Language/IP Units SD2504SN 04/17 ontractor: 5 Series 500O11 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY OUTDOO SPLIT EOTHEMAL HEAT PUMPS DUAL APAITY MODELS: YAST026-072 (2 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air onditioning SUBMITTAL SET AFFINITY EOTHEMAL HEAT PUMPS DUAL APAITY OMBINATION MODELS: YAT038-07 (3 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject

More information

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog. Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3

More information

Residential Packaged Geothermal Heat Pump

Residential Packaged Geothermal Heat Pump ENGIneering Design Guide Residential Packaged Geothermal Heat Pump HP Series 1 1 /2 to 5 Tons Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Engineering

More information

HEAT CONTROLLER, INC. HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps

HEAT CONTROLLER, INC. HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HC Series 1/2 to 5 Tons Commercial Water Source Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100

More information

Premier Split Specification Catalog

Premier Split Specification Catalog Geothermal Split Units 1-1/2 thru 5 Tons Design Features Dimensional Data Physical Data Premier Split Specification Catalog Performance Data Engineering Guide Specifications SP1557 03/09 WaterFurnace WaterFurnace

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

HEAT CONTROLLER, INC.

HEAT CONTROLLER, INC. HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax 517-787-9341 www.heatcontroller.com MODEL NOMENCLATURE

More information

Large Belt Drive (HBH/V) Series HBH HBV

Large Belt Drive (HBH/V) Series HBH HBV Design Guide Large Belt Drive (HBH/V) Series HBH 072-120 HBV 072-300 60Hz - HFC-410A 517.787.2100 www.marsdelivers.com www.heatcontroller.com Table of Contents *Page Number Unit Features.... 2 Selection

More information

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility High Efficiency () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A English Language/I-P Units Submittal Data - I-P Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

Tranquility 16 (TR) Series Submittal Data

Tranquility 16 (TR) Series Submittal Data Tranquility 16 () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A *LC516* LC516 Rev.: October 6, 2017 LC516-2 Table of Contents Series Unit Features 4 Selection Procedure 5 Series Nomenclature

More information

Tranquility Water-To-Water (TMW) Series

Tranquility Water-To-Water (TMW) Series Tranquility Water-To-Water (TMW) Series Submittal Data Model TMW036-340 60Hz - HFC-410A *LC402* LC402 Rev.: November 18, 2016 Table of Contents TMW Water-To-Water Series Unit Feature 3 Selection Procedure

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)

More information

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model

More information

Tranquility 16 (TR) Series Submittal Data

Tranquility 16 (TR) Series Submittal Data Tranquility 16 () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility Large Vertical (TLV) Series Submittal Data Models TLV08-300 50Hz - HFC-10A English Language/S-I Units Submittal Data - S-I Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual P.O. Box 245 Syracuse, NY 13211 www.roth-usa.com info@roth-usa.com 888-266-7684 Table of Contents: RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS XT 024-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS HT 024-060 HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS 20D214-06NN 20D214-06NN

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

GT-PX SPLIT (50YDS) SERIES. Carrier Geothermal Heat Pump Systems GT-PXS 1. All Products Technical Guide:

GT-PX SPLIT (50YDS) SERIES. Carrier Geothermal Heat Pump Systems GT-PXS 1. All Products Technical Guide: Carrier Geothermal Heat Pump Systems GT-PX SPLIT (50YDS) SERIES TWO-STAGE INDOOR SPLIT PURON SYSTEMS SIZES 026-064 [7.0-19.3 kw] All Products Technical Guide: 2006-2007 1 GT-PX Split (50YDS) Series Table

More information

RK Series. RK Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features.

RK Series. RK Series Engineering Guide. Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant Ton. Design Features. RK Series Commercial Water Source/Geothermal Heat Pump R-410A Refrigerant 0.75-6 Ton RK Series Engineering Guide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

ENGINEERING SPECIFICATIONS:

ENGINEERING SPECIFICATIONS: Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS VS/VT 006-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features.

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features. RG Series Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant 0.75-6 Ton RG Series Engineering Guide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

Geothermal Heat Pump Systems

Geothermal Heat Pump Systems SUBMITTAL DATA Geothermal Heat Pump Systems Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DATA Cooling Capacity BTUH EER Heating Capacity BTUH COP Model HTS 024-060 60 Hz R-410A Ambient

More information

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open

More information

NXW 10 TO 50 TON. Commercial Reversible Chiller - 60 Hz. Submittal Data English Language IP/Metric Units SD2502WN 06/14

NXW 10 TO 50 TON. Commercial Reversible Chiller - 60 Hz. Submittal Data English Language IP/Metric Units SD2502WN 06/14 NXW 0 O 50 ON Commercial Reversible Chiller - Hz Submittal Data English Language IP/Metric Units SD50WN 06/4 Model Nomenclature -3 4-6 7 8 9 0 3 NXW R 3 A E 8 N N 4-5 SS 6 * Model NXW Envision Series Reversible

More information

Envision Indoor Split Specification Catalog

Envision Indoor Split Specification Catalog Envision Series Geothermal Indoor Split Heat Pumps -410A efrigerant 2 thru 6 Ton Single Speed 2 thru 6 Ton Dual apacity Design Features Factory Options Accessories Dimensional Data Physical Data Performance

More information

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits

More information

AFFORDABLE RENEWABLE CLEAN

AFFORDABLE RENEWABLE CLEAN Specification atalog GEOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN Aston Series Indoor Split Table of ontents General Introduction... 4 Model Nomenclature... 5 AHI Data... 6-7 Design Features..................................................................8

More information

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features.

RG Series. RG Series Engineering Guide. Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant Ton. Design Features. R Series Commercial eothermal/water Source Heat Pump R-410A Refrigerant 0.75-6 Ton R Series Engineering uide Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data

More information

TRANQUILITY 20 SINGLE-STAGE (TS) SERIES

TRANQUILITY 20 SINGLE-STAGE (TS) SERIES TRANQUILITY 20 SINGLE-STAGE () SERIES SIZE 006-070 (1.76kW - 21.1kW) HORIZONTAL, VERTICAL & DOWNFLOW R410A - 60Hz STANDARD & EXTENDED RANGE R410A - 60Hz STANDARD & EXTENDED RANGE SIZE 018-070 (5.3kW -

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SPECIFICATION CATALOG LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement,

More information

Tranquility Compact (TC) Series Submittal Data

Tranquility Compact (TC) Series Submittal Data Tranquility Compact (TC) Series Submittal Data Models TCH/V006-060 60Hz - HFC-410A *LC405* LC405 Rev.: August 21, 2018 Table of Contents TC Compact Packaged Series Unit Features 4 Selection Procedure 5

More information

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY

SPECIFICATION CATALOG GEOTHERMAL/WATER SOURCE INDOOR SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL CAPACITY SPEIFIATION ATALOG GEOTHEMAL/WATE SOUE INDOO SPLIT HEAT PUMP 2 TO 6 TON SINGLE SPEED 2 TO 6 TON DUAL APAITY Table of ontents Introduction... 4 Model Nomenclature.... 5 AHI Data... 6-7 Design Features...

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

Compact (HBH/V) Series HBH-HBV

Compact (HBH/V) Series HBH-HBV Submittal Data Compact (HBH/V) Series HBH-HBV 006-60 60Hz - HFC-410A 517.787.2100 www.marsdelivers.com www.heatcontroller.com Compact (HBH/V) Series Submittal Data Models HBH/V 006-060 60Hz - HFC-410A

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

ARBOR SERIES AFFORDABLE RENEWABLE CLEAN

ARBOR SERIES AFFORDABLE RENEWABLE CLEAN ARBOR SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN Table of Contents Model Nomenclature............................................................. 4 AHRI Data.....................................................................

More information

Specification Manual

Specification Manual Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits

More information

WE MAKE INDOOR AIR BETTER

WE MAKE INDOOR AIR BETTER WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GS Performance Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.4-4.5 COP, 15.4-26.4 EER (Closed Loop) S 3.9-5.1 COP, 19.2-30.5 EER (Open

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GZ Infinityr Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.3-4.6, 14.8-28.8 (Closed Loop) S 3.8-5.2, 19.2-29.1 (Open Loop) S Optional

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.5 to 6 Ton Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature.............................................................. 4 AHRI Data......................................................................

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

ENGINEERING DESIGN GUIDE

ENGINEERING DESIGN GUIDE ENGINEERING DESIGN GUIDE Commercial Horizontal & Vertical Packaged Water-Source Heat Pumps: Compact Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Table

More information

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN

ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN ARBOR BASE SERIES C O M M E R C I A L U N I T S AFFORDABLE RENEWABLE CLEAN Table of Contents Model Nomenclature.............................................................. 4 AHRI Data.....................................................................

More information

Small SpaceKeeper Vertical (SKV)

Small SpaceKeeper Vertical (SKV) Small SpaceKeeper Vertical (SKV) SKV 008-018 ¾ - 1½ tons 17 W x 17 L x 48 H SKV 020-036 1¾ - 3 tons 20 W x 20 L x 57 H SKV 042-060 3½ -5 tons 24 W x 24 L x 59 H * For large capacity vertical units see

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SPECIFICATION CATALO LX SERIES EOTHERMAL HEAT PUMPS SINLE AND DUAL CAPACITY MODELS: YLF 026-072 (2 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.5 to 6 Ton. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.5 to 6 Ton Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature........................................................... 4 AHRI Data...................................................................5-6

More information

HEAT CONTROLLER, INC. HT Series HT GeoMax2 Two-Stage. 2 to 5 Tons

HEAT CONTROLLER, INC. HT Series HT GeoMax2 Two-Stage. 2 to 5 Tons HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HT Series HT GeoMax2 Two-Stage 2 to 5 2 to 5 Tons HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax

More information