EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.
|
|
- Abner Gallagher
- 6 years ago
- Views:
Transcription
1 EMIP60 ISO EM Series, Inch Pounds 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: Changed EM170/240HZ dwg Changed HZ dwg to field convertible EM360 coil area to ft sq Guide Specification updated Removed EM051 and EM Reinstated EM051 and EM Updated HZ drawing EM012 WL COP changed Corrected EM filter rack dimensions
2 GUIDE SPECIFICATIONS EM Series 1/26 Ton GENERAL Units shall be performance certified to ISO standard for Water Loop Heat Pump, Ground Water Heat Pump and Ground Loop Heat Pump applications. Units intended for use on ground loop applications shall have an optional extended range package installed. Units shall be Underwriter Laboratories (UL and cul) listed for safety on all models. Each unit shall be run tested at the factory. Each unit shall be pallet mounted and stretch wrapped. The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of one year on all parts, and 5 years on the compressor. The units shall be designed to operate with entering fluid temperatures between 50 O F (10 O C) and 100 O F (38 O C) in cooling and between 50 O F (10 O C) and F (27 O C) in heating. With the optional factory installed extended range package units shall operate with entering fluid temperatures between 50 0 F (10 O C) and 110 O F (43.3 O C) in cooling and between 25 O F (3.9 O C) and F (27 O C) in heating. CASING & CABINET The cabinet shall be fabricated from heavygauge steel finished with Galvalume plus, an aluminumzinc alloy with a clear acrylic coating for additional corrosion protection. The interior shall be insulated with ½ (12.7mm) thick, multi density, coated, glass fiber. All units shall allow sufficient service access to replace the compressor without unit removal. One blower and two compressor compartment access panels shall be removable with supply and return ductwork in place. A duct collar shall be provided on the supply air opening. A 2" (50.8mm) return air filter rack/duct collar with 1" (25.4mm) thick filters shall be provided with each unit. The units shall have an insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise, and to permit service testing without air bypass. Units shall have a stainless steel condensate drain pan. REFRIGERATION CIRCUITS All units shall contain a sealed refrigerant circuit including a hermetic compressor, capillary tube metering device with strainer or balance port expansion valve, finned tube airtorefrigerant heat exchanger, refrigerant reversing valve and service ports. Compressor shall be high efficiency, designed for heat pump duty, internally spring isolated (if reciprocating type) for maximum sound attenuation and mounted on rubber vibration isolators. Compressor motors shall be equipped with overload protection. Refrigerant reversing valves shall be pilot operated sliding piston type with replaceable encapsulated magnetic coils energized only during the cooling cycle. The finned tube coil shall be constructed of lanced aluminum fins not exceeding fourteen fins per inch bonded to rifled copper tubes in a staggered pattern not less than three rows deep and have a 450 PSIG (3100 kpa) working pressure. Coils shall be epoxy coated using an electro coating process for protection against most airbourn chemicals.the coil shall have aluminum end sheets. The coaxial watertorefrigerant heat exchanger shall be constructed of a convoluted copper (optional cupronickel) inner tube and steel outer tube with a designed refrigerant working pressure of 450 PSIG (3100 kpa) and designed water side working pressure of no less than 400 PSIG (2750 kpa). EXTENDED RANGE PACKAGE An optional extended range package shall include a biflow balanced port expansion valve metering device in place of capillary tubes and insulated water to refrigerant heat exchanger. FAN MOTOR & ASSEMBLY The fan shall be direct drive centrifugal forward curved type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low velocity operation. The fan housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the fan motor. The fan motor shall be three speed PSC type for direct drive units and single speed for belt drive units. The motor shall be permanently lubricated and have thermal overload protection. ELECTRICAL Controls and safety devices will be factory wired and mounted within the unit. Controls shall include fan relay, compressor contactor, 24V transformer, reversing valve coil and solid state lockout controller (UPM) The UPM controller shall include the following features: Antishort cycle time delay, random start, brown out/surge/power interruption protection, 90 second low pressure switch bypass timer, shutdown on high or low refrigerant pressure safety switch inputs, shutdown for the optional freezestat or high level condensate sensors, 24 VAC alarm output for remote fault indication, unit reset at thermostat or disconnect, ability to defeat time delays for servicing and automatic intelligent reset. The UPM shall automatically reset after a safety shut down and restart the unit, if the cause of the shut down no longer exists, after the antishort cycle and random start timers expire. Should a fault reoccur within 10 minutes after reset, then a permanent lockout will occur. A light emitting diode (LED) shall annunciate the following alarms: high refrigerant pressure, low refrigerant pressure, low water temperature and a high level of condensate in the drain pan (when equipped with the optional low water temperature and high level condensate sensors). The LED will display each fault condition as soon as the fault occurs. If a permanent lockout occurs, then the fault LED will display the type of fault until the unit is reset. Safety devices include a low pressure cutout set a 20 PSIG (140 kpa) for loss of charge protection (freezestat and/or high discharge gas temperature sensor is not acceptable) and a high pressure cutout control set at 380 PSIG (2600 kpa). An optional energy management relay that allows unit control by an external source shall be factory installed. A terminal block with screw terminals shall be provided for control wiring. PIPING Supply, return water and condensate drain connections shall be brass female pipe thread fittings and mounted flush to cabinet exterior with optional stainless steel, Braided hose kit with swivel connectors. EMSPECS.P65 REV: 903
3 GUIDE SPECIFICATIONS EM Series 630 Large Commercial GENERAL Units shall be performance certified to ISO standard for Water Loop Heat Pump, Ground Water Heat Pump and Ground Loop Heat Pump applications for units up to 10 tons. Units intended for use on ground loop applications shall have an optional extended range package installed which consists of an insulated water to refrigerant heat exchanger. Units shall be Underwriter Laboratories (UL and cul) listed for safety on all models. Each unit shall be run tested at the factory. Each unit shall be pallet mounted and stretch wrapped. The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of one year on all parts, and 5 years on the compressor. The units shall be designed to operate with entering fluid temperatures between 50 o F (10 o C) and 100 o F (38 o C) in cooling and between 50 o F (10 o C) and 80 o F (27 o C) in heating. With the optional factory installed extended range package units shall operate with entering fluid temperatures between 50 o F (10 o C) and 110 o F (43.3 o C) in cooling and between 25 o F (3.9 o C) and 80 o F (27 o C) in heating. CASING & CABINET The cabinet shall be fabricated from heavygauge galvanized steel. The interior shall be insulated with ½ (12.7mm) thick, multi density, coated, glass fiber. All units shall allow sufficient service access to replace the compressors without unit removal. Two blower and two compressor compartment access panels shall be removable with supply and return ductwork in place. A duct collar shall be provided on the supply air opening of all vertical units. A 2" (50.8mm) return air filter rack/duct collar with 1" (25.4mm) thick filters shall be provided with each unit. Vertical units shall have an insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise, and to permit operational service testing without air bypass. Units shall have stainless steel condensate drain pan(s). REFRIGERATION CIRCUITS All units shall contain sealed refrigerant circuits including hermetic compressors, thermal expansion valve metering devices, finned tube airtorefrigerant heat exchangers, refrigerant reversing valves and service ports. Compressors shall be high efficiency, designed for heat pump duty, internally spring isolated (except for scroll type compressors) for maximum sound attenuation and mounted on rubber vibration isolators. Compressor motors shall be equipped with overload protection. Refrigerant reversing valves shall be pilot operated sliding piston type with replaceable encapsulated magnetic coils energized only during the cooling cycle. The finned tube coil shall be constructed of lanced aluminum fins not exceeding fourteen fins per inch bonded to rifled copper tubes in a staggered pattern not less than three rows deep and have a 450 PSIG (3100 kpa) working pressure. Coils shall be epoxy coated using an electro coating process for protection against most airbourn chemicals.coils shall have aluminum end sheets. The coaxial watertorefrigerant heat exchangers shall be constructed of a convoluted copper (optional cupronickel) inner tube and steel outer tube with a designed refrigerant working pressure of 450 PSIG (3100 kpa) and a designed water side working pressure of no less than 400 PSIG (2750 kpa). FAN MOTOR & ASSEMBLY(S) The fan(s) shall be belt driven DWDI forward curved type with dynamically balanced wheel(s). The housing(s) and wheel(s) shall be designed for quiet low velocity operation. The fan housing(s) shall be removable from the unit without disconnecting the supply air ductwork for servicing of the fan motor(s). The fan motor(s) shall be 1725 or 3450 RPM 56 frame sealed ball bearing type. The motor(s) shall be permanently lubricated and have thermal overload protection. ELECTRICAL Controls and safety devices will be factory wired and mounted within the unit. Controls shall include fan relay(s), compressor contactors, 24V transformer, reversing valve coils and a solid state lockout control circuit (UPM). The UPM controller shall include the following features: Antishort cycle time delay, random start, interstage delay, brown out/surge/power interruption protection, 90 second low pressure switch bypass timer, shutdown on high or low refrigerant pressure safety switch inputs, shutdown for the optional freezestat or high level condensate sensors, 24 VAC alarm output for remote fault indication, unit reset at thermostat or disconnect, ability to defeat time delays for servicing, time delay between stages and automatic intelligent reset. The UPM shall automatically reset after a safety shut down and restart the unit, if the cause of the shut down no longer exists, after the antishort cycle and random start timers expire. Should a fault reoccur within 10 minutes after reset, then a permanent lockout will occur. A light emitting diode (LED) shall annunciate the following alarms for each refrigerant circuit: high refrigerant pressure, low refrigerant pressure, low water temperature and a high level of condensate in the drain pan (when equipped with the optional low water temperature and high level condensate sensors). The LED will display each fault condition as soon as the fault occurs. If a permanent lockout occurs, then the fault LED will display the type of fault until the unit is reset. Safety devices include a low pressure cutout set at 20 PSIG (140 kpa) for loss of charge protection (a freezestat used for loss of charge protection is not acceptable) and a high pressure cutout control set at 380 PSIG (2600 kpa). An optional energy management relay to allow unit control by an external source shall be factory installed. PIPING Supply, return water and condensate drain connections shall be copper or brass female pipe thread fittings and mounted flush to cabinet exterior. LEMSPECS.P65 Rev: 903
4 FHP Manufacturing Co. Phone: (954) Fax: (800) EM Series Ver ertical Dimensions A B C D E F G H J K M N P Q Condenser Recommended MODEL R/A Duct R/A Duct Filter Rack Water Replacement Width Depth Height Flg Width Flg Height Height Connections Nominal Filter Size EM007, /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 18 X 20 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 24 X 24 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 24 X 24 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 16 X 30 X 1 (2) Left Hand Return (FLT) EMVTGDIP FLA.P65 REV: 0903 Right Hand Return (FRT) NOTES: All dimensions within +/ 0.125". All condensate drain connections are 3/4" FPT. EM051 and 061 only available in vertical configuration. Specifications subject to change without notice.
5 FHP Manufacturing Co. Phone: (954) Fax: (800) EM Series Horizontal Dimensions A B C D E F G H J K M N P Q R T Condenser Recommended MODEL R/A Duct Filter Rack R/A Duct Water Replacement Width Depth Height Flg Width Height Flg Height Connections Nom. Filter Size EM007, /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 18 X 20 X 1 EM /4" F.P.T. 18 X 20 X 1 EM /4" F.P.T. 18 X 20 X 1 EM /4" F.P.T. 18 X 30 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 18 X 30 X 1 EM " F.P.T. 18 X 20 X 1 (2) EM " F.P.T. 18 X 20 X 1 (2) EM " F.P.T. 20 X 24 X 1 (2) Left Hand Return (Note: Models EM048 & 060 Left Hand Return units have condenser water connections on the front right and electrical knockouts on the front left.) Left Hand Return End Blow (FLE) Left Hand Return Straight Through (FLS) Right Hand Return Right Hand Return Straight Through (FRS) EMHZDGIP.P65 c FHP Manufacturing Company REV:91103 Right Hand Return End Blow (FRE) NOTES: All dimensions within +/ 0.125". All condensate drain connections are 3/4" FPT. Specifications subject to change without notice. EM can be field converted between end blow and straight through supply air configurations
6 FHP Manufacturing Co. Phone: (954) Fax: (800) EM Series Counterflow Dimensions A B C D E F G H J K M N P Condenser Recommended MODEL R/A Duct R/A Duct Filter Rack Water Replacement Width Depth Height Opening Opening Flg Width Flg Height Height Connections Nominal Filter Size EM007, /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 10 X 16 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 16 X 20 X 1 EM /4" F.P.T. 18 X 20 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 24 X 24 X 1 EM /4" F.P.T. 20 X 20 X 1 EM /4" F.P.T. 24 X 24 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 24 X 30 X 1 EM " F.P.T. 16 X 30 X 1 (2) Left Hand Return (FLB) Right Hand Return (FRB) EMCFDGIP.P65 REV: NOTES: All dimensions within +/ 0.125". All condensate drain connections are 3/4" FPT. Specifications subject to change without notice.
7 Dimensions All Dimensions +/ 0.125" FHP Manufacturing Co. Phone: (954) Fax: (800) EM Ver ertical Dimensions Single Large Commercial Units Optional Orientation (979032) Front Return Standard Orientation Dimension Model Height Width Depth Condenser Connections A B C Dia. (FPT) 1.00" 1.00" 1.50" 2.00" 2.00" Return Air Opening D(Duct Flange) E(Filter Rack) Replacement Filter Size 072 through x 341/2 x 1 (2 per unit) x 341/2 x 1 (2 per unit) Top Supply (FFT) Rear Supply (FFR) Rear Return Standard Orientation Optional Orientation (979032) Service Access Panel # Access To: 1 Controls, Compressors, Refrigeration Components 2 & Motor 3 Top Supply (FBT) Front Supply (FBF) Notes: Condensate connections are 0.75" FPT on 072 through 120 and 1.25" FPT on 150 and 180. Due to continuing research and development, specifications are subject to change without notice. EMSVDGIP.P65 Rev
8 FHP Manufacturing Co. Phone: (954) Fax: (800) Dimensions All Dimensions +/ 0.125" Dimension Model Height Width Depth Return Air Dimensions A B C Condenser Connections E F G H Diameter 1"FPT 1"FPT 1.25"FPT 1.50"FPT Supply Air Dimensions ( Outlet) J K L Replacement Filter Size x 341/2 x 1 (2 per unit) x 34 x 1 (2 per unit) Service Access Panel# Access To: 1 Controls, Compressors 2 & Motor 3 Compressors, Refrigeration Components EM Horizontal Dimensions 072, 096 & 140 (SLS Only) 120 (SLS Only) Notes: All condensate connections are 0.75" FPT. Due to continuing research and development, specifications are subject to change without notice. EMLHDGIP.P65 Rev. 401
9 FHP Manufacturing Co. Phone: (954) Fax: (800) EM Horizontal Dimensions EM170 SLS CONFIGURATION ONLY Dimensions Condenser Connections EM "FPT EM "FPT Notes: All dimensions +/ 0.125". All condensate connections are 1.25" FPT. EM240 SLS CONFIGURATION ONLY Replacement Filter Size EM x 34 x 1 (2) EM x 341/2 x 1 (4) Service Access Panel# Access To: 1 Controls, Compressors, Refrigeration Components 2 s & Motors 3 Compressors, Refrigeration Components Due to continuing research and development, specifications are subject to change without notice. EM170240HZIP.P65 Rev.802
10 FHP Manufacturing Co. Phone: (954) Fax: (800) EM Ver ertical Dimensions Dual Large Commercial Units Dimensions All Dimensions +/ 0.125" Model Height A B C D E Front Return Top Supply (FFT) Optional Orientation (979033) Standard Orientation Model Condenser Condensate Connection Drain Diameter Diameter "FPT 1.25"FPT "FPT 1.25"FPT "FPT 1.25"FPT "FPT 1.25"FPT "FPT 1.25"FPT "FPT 1.25"FPT Rear Return Front Supply (FBF) Standard Orientation Optional Orientation (979033) Front Return Rear Supply (FFR) Recommended Replacement Filter Size (Nominal) 20 x 341/2 x 1 (4 per unit, ) 30 x 341/2 x 1 (4 per unit, 360) Service Access Panel # Access To: 1 Controls, Compressors, Refrigeration Components 2 & Motor 3 Rear Return Top Supply (FBT) Due to continuing research and development, specifications are subject to change with out notice. EMDVDGIP.P65 Rev:
11 Compressor Min. Max / Speed High Medium Low All performance at 300 CFM and 1.9 GPM PACKAGE UNITS EM007 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 300 CFM and 2.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 12 Size Net Ship 4x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM007IP6ISO.P65 Rev:11399
12 Compressor Min. Max / Speed High Medium Low All performance at 350 CFM and 2.4 GPM PACKAGE UNITS EM009 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 350 CFM and 3.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 12 Size Net Ship 4x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM009IP6ISO.P65 Rev: 11399
13 Compressor Min. Max / Speed High Medium Low All performance at 400 CFM and 3.0 GPM PACKAGE UNITS EM012 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 400 CFM and 3.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 4x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM012IP6ISO.P65 Rev:92203
14 Compressor Min. Max. 208/ Speed High Medium Low All performance at 500 CFM and 3.8 GPM PACKAGE UNITS EM015 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 500 CFM and 4.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 4x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM015IP6ISO.P65 Rev:11399
15 Compressor Min. Max. 208/ Speed High Medium Low All performance at 650 CFM and 4.7 GPM PACKAGE UNITS EM018 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 650 CFM and 5.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM018IP6ISO.P65 Rev 11399
16 Compressor Min. Max. 208/ Speed High Medium Low 670 All performance at 850 CFM and 5.8 GPM PACKAGE UNITS EM024 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 850 CFM and 6.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM024IP6ISO.P65 Rev:11399
17 Compressor Min. Max. 208/ / Speed High Medium Low All performance at 950 CFM and 7.0 GPM PACKAGE UNITS EM028 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 950 CFM and 7.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM028IP6ISO.P65 Rev:11399
18 Compressor Min. Max. 208/ / Speed High Medium Low All performance at 1000 CFM and 8.1 GPM PACKAGE UNITS EM031 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ARI / ISO PERFORMANCE DATA Rated at 1000 CFM and 7.5 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM031IP6ISO.P65 Rev:11599
19 Compressor Min. Max. 208/ / Speed High Medium Low All performance at 1200 CFM and 8.6 GPM PACKAGE UNITS EM036 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 1200 CFM and 9.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM036IP6ISO.P65 Rev:11399
20 Compressor Min. Max. 208/ / Speed High Medium Low All performance at 1150 CFM and 9.8 GPM PACKAGE UNITS EM041 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 1150 CFM and 9.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM041IP6ISO.P65 Rev:12199
21 Compressor Min. Max. 208/ / Speed High Medium Low All performance at 1500 CFM and 10.4 GPM PACKAGE UNITS EM042 HIGHEFFICIENCY WATER SOURCE HEAT PUMPS ISO PERFORMANCE DATA Rated at 1500 CFM and 10.0 GPM table for GLHP performance Water Wet Capacity Rejection Ent. Air Temp. EER For extended range performance beyond the ranges shown on the tables below, the extended range option must be installed /8 14 Size Net Ship 9x ENERGYMISER Water Capacity Absorb. COP 50 O O O Units are complete packages containing refrigeration compressor, reversing valve, capillary tube metering device, and water to refrigerant heat exchanger. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a lockout control circuit. 85 O 67 O Extended range option includes expansion valve metering device, insulated water coil and solid state lockout controls O 67 O Phone: (954) Fax: (800) As a result of continuing research and development, specifications are subject to change without notice. EM042IP6ISO.P65 Rev:12199
GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers
GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed
More informationGUIDE SPECIFICATIONS CE Series Two Stage R-410A
GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall
More informationGUIDE SPECIFICATIONS. ES Series R-410A
GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter
More informationFHP s EnviroSaver the best investment for your environment and home.
EnviroSaver The two-stage EnviroSaver from FHP provides you with a unit that will suit your budget while incorporating innovative technology for reduced energy costs. FHP was the industry leader in introducing
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationSi Series Model CE Residential Geothermal Heat Pump
Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationCDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications
CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationSPLIT SYSTEMS. Air Handling Unit. Condensing Section
SPLIT SYSTEMS Air Handling Unit Condensing Section EC Series Split Systems Condensing Sections Dimensions ISO 13256-1 Certified Performance MODEL L W H Water WLHP Cooling WLHP Heating GWHP Cooling GWHP
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationProduct Data. S Two-stage scroll compressor S Variable speed blower motor Control
GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationMcQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog
Catalog 1100-6 McQuay Enfinity TM Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060 Model FCV & FCW Vertical Floor Size 007 060 Table of Contents
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationProduct Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control
GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationProduct Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps
Product Data 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps 1/ 2 to 6 Nominal Tons TM Carrier s Aquazone single-packaged horizontal and vertical water source heat pumps
More informationCDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications
CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationLiebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller
DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS NORDIC RH-55-HACW-P-1T-*-SDE*F Horizontal Two-Stage R410a Model Size 55 (Nominal 4 Ton) Reversing (Heating AND Cooling) Domestic Hot Water (desuperheater) 230-1-60VAC Liquid
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationWE MAKE INDOOR AIR BETTER
WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationProduct Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)
SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationLow Profile Unit Cooler
Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More information10AC DIPLOMAT SERIES RFC SYSTEMS
10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA
More informationHS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin
More informationMcQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationEngineering Data Submittal Manual
Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationSINGLE PACKAGE HEAT PUMPS
SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections
More informationBC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)
BCAHSG-2 3-Jun BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) 5 YEAR WARRANTY see warranty form for details Contents: Page Number Product Features 2
More informationProduct Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts)
MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH Product Manual C: 1155-10 Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to 350 Watts) WATER TO AIR BRINE
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationSCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS
SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationTranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]
Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationBVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS
BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationengineering guide Air-Cooled Self-Contained Units
engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................
More informationModular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationTypical Applications. Horizontal Installation
ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationHS22 Bulletin # November 1992 Supersedes September 1990
ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationSerenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.
Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationZHA/ZHB SERIES WARNING
Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationPGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No
PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained
More informationHS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353
More informationMcQuay Rooftop Water Source Heat Pumps Catalog 1106
McQuay Rooftop Water Source Heat Pumps Catalog 06 Model RWA, RGA Downflow Discharge and Return Model, RWC, RGC Horizontal Discharge and Return Unit Sizes 036 R-A Refrigerant Model RWA Engineered for flexibility
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationMEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS
1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM
More informationEngineering Data Submittal Manual
Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS HT 024-060 HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS 20D214-06NN 20D214-06NN
More informationS/T Ratio. Input BTU/h
SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most
More informationCDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications
CDI series Model TW Residential to Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options and Control Options Standard Features White Pre-Painted Sheet
More information"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units
"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units Spinnaker Industries Inc. Model Series SPOAU 100% Outdoor Air Systems shall be factory assembled, wired and
More information