Correlator rack internal mechanical and electrical specs B. Carlson
|
|
- Sheila Hudson
- 5 years ago
- Views:
Transcription
1 Correlator rack internal mechanical and electrical specs B. Carlson National Research Council Canada Conseil national de recherches Canada EVLA Correlator Meeting Nov. 1, 2006
2 Outline Overview; based on A25017N0005 V VDC power routing. RPMIB/PMCS connections. Hi-speed cable routing. M&C Ethernet routing. B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 2
3 M&C 1000Base-T Ethernet Data 1000Base-T Ethernet Power M&C -48 VDC power in Rack Floor Hi-speed HM Gbps interrack cable Cooling air in (~1700 cfm) B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 3
4 100-pin SCSI 0 21 OUTPUTS F1 F2 JP 100-pin SCSI ID INPUTS 48VR GND F3 F4 Air duct Breakers -48 VDC Power entry/ Breaker panel Rear vertical rail Middle vertical rail Front vertical rail -48V Power kill switch RET Sub-rack load bar RPMIB RPMIB panel Ethernet switch Ethernet switch Top 12U crate Flying cable backshells Common Backplanes 6U crate Universal strain relief bars Bottom 12U crate Approx 9" Approx 6" REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 4
5 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 5
6 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 6
7 -Need physical demux box and fiber+connectors to test rack prototype mechanics. -Need to discuss routing of fiber from demux box to Station Boards DTS receivers. B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 7
8 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 8
9 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 9
10 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 10
11 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 11
12 100-pin SCSI 100-pin SCSI 0 21 OUTPUTS RPMIB 0 18 INPUTS ID VR F1 F2 JP F3 F4 GND B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 12
13 100-pin SCSI 0 21 OUTPUTS F1 F2 100-pin SCSI ID INPUTS 48VR GND F3 F4 Fan power wires -48 V and 48VRET from main distribution panel -48 VDC and 48VRET from main distribution panel Fan power wires Breakers -48 VDC bus bar V Contactor (kill switch) RET 48VRET bus bar JPRPMIB Ethernet switch power SS relays Fan power connections Ethernet Switch Ethernet switch EMI filter (CM choke) Ethernet switch power connector Top 12U crate Power connection PCBs-- vertical Power connection PCB-- horizontal 6U crate Bottom 12U crate REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 13
14 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 14
15 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 15
16 B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 16
17 100-pin SCSI 0 21 OUTPUTS F1 F2 JP 100-pin SCSI ID INPUTS 48VR GND F3 F4 Fan M&C 100-pin cables to CPCCs in Control Racks -48V Fan M&C 100-pin cables to CPCCs in Control Racks RET RPMIB RPMIB REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 17
18 100-pin SCSI 0 21 OUTPUTS F1 F2 JP 100-pin SCSI ID INPUTS 48VR GND F3 F4-48V RET RPMIB Intra-rack cables Cables from Station Racks REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 18
19 m 0.5 m 0.5 m m 0.5 m 0.75 m 2 examples from Baseline rack hispeed wiring plan m 0.5 m 0.5 m 0.75 m St. 2 Plan requires update for Phasing Boards B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 19
20 100-pin SCSI 0 21 OUTPUTS F1 F2 JP 100-pin SCSI ID INPUTS 48VR GND F3 F4-48V RET RPMIB Hi-speed cables to Baseline racks TIMECODE distribution cables Hi-speed cables to Baseline racks REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 20
21 100-pin SCSI 0 21 OUTPUTS F1 F2 JP 100-pin SCSI ID INPUTS 48VR GND F3 F4 RJ-45 couplers Gbit Ethernet to CBE switch RJ-45 couplers 2X M&C Ethernet from Control Racks Gbit Ethernet to CBE switch Gbit Ethernet to CBE switch RJ-45 couplers -48V RET RPMIB Rack horizontal support beams REAR VIEW SIDE VIEW B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 21
22 M&C & Gbit Ethernet cables Baseline Boards 10 7/16" 6U sub-rack front-panel door 21 9/16" Captive M2.5 thumb-screws Ejector Handles B. Carlson, 2006-Nov 1 EVLA Correlator Meeting - Corr Rack Internal 22
Installing the Switch
CHAPTER 3 Revised: January 4, 2012 This chapter describes how to install the Catalyst 4900M switch. For first-time installations, perform the procedures in the following sections in the order listed. Checking
More informationAccess your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.
Z Hinged Fiber Adapter Panel Enclosure Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber. Customer Support Information Order
More informationACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:
ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,
More informationDelta Products VFD CP2000 Bypass Control Packages.
Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products
More informationPanView iq (PViQ) Fiber Tray
PVQ-FMT PanView iq (PViQ) Fiber Tray Part Number: PVQ-FMT Contents: 1 - FIBER TRAY (HOUSING & DRAWER) 6 - #12-24 x 1/2" SCREWS 6 - M6 x 1.0 x 16 SCREWS 2 - STRAIN RELIEF BRACKETS 2 - #10-32 BLACK HEX NUTS
More informationIM /2017 REV01 POWER WAVE S700 CE
POWER WAVE S700 CE IM2061 09/2017 REV01 Spare Parts... 1 POWER WAVE S700 CE... 1 Miscellaneous Items... 1 POWER WAVE S700 CE Assemblies overview... 2 Figure 1: Case Front Assembly... 3 Figure 2: Lower
More informationaccessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents
Indoor AP Compatible Products Description Picture Kit Contents 902-0100-0000 ZoneFlex 7982 ZoneFlex R700 Multipurpose mounting bracket for 7982 supports mounting to hard wall, ceiling, electrical outlet
More informationCONEC provides reliable and effective solutions to OEM, EMS and cable houses.
CONEC CANADA USA CONEC designs and manufactures products in modern facilities. The products are made in accordance to the highest quality standards and industry specifications. CONEC provides reliable
More informationTender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read
Tender for procurement of Passive Components of LAN & Wi-Fi and their installation Corrigenda Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 1. Annexure-I, Point No. 1.3 24 Port
More informationCombiTac Overview. CombiTacline Industrial Connectors
CombiTac Overview CombiTacline Industrial Connectors CombiTac Modular Connector System As a solution provider, Stäubli offers customers worldwide A-Z support in designing their own 100 % customized CombiTac
More informationCamera Electronics Systems
Camera Electronics Systems September 2008 Rick Van Berg Outline Camera Electronic Systems Science Electronics (including corner rafts) Power regulation and distribution Cabling Controllers / sensors Safety
More informationRFQ-YEM Solar Lighting System for UNDP
AMENDMENT 1 for RFQ-YEM-0076-2016 Solar Lighting System for UNDP This Amendment is issued after the Pre-bid meeting and site visit arranged as mentioned on the RFQ docs and the results as following: To
More informationDHE Chassis and Cooling
DHE Chassis and Cooling DES Mechanical Workshop at FNAL November 2, 2005 Vaidas Simaitis High Energy Physics Group University of Illinois at Urbana-Champaign 1 6-SLOT + 4-SLOT CHASSIS 2 FAN MANIFOLDS ADDED
More informationWrg_0069A_01of12_104d_21101_std
129 SECTION 12 104D Wrg_0069A_01of12_104d_21101_std 130 Wrg_0069A_02of12_104d_21102_std 131 Wrg_0069A_03of12_104d_21060_std CONNECTOR J1 PIN SIGNAL 1 SLIDE EXTENDED 2 TURRET COUNT 3 SPINDLE ORIENTED 4
More informationDirectory chapter 01
Directory chapter 01 Miniature D connectors, 1.27 mm pitch Page I/O connectors................................................. 01.02 Pin and socket Technical characteristics........................................
More informationMULTI-ZONE FOAMED MACHINE MODEL PARTS MANUAL
MULTI-ZONE FOAMED MACHINE MODEL - 3576 PARTS MANUAL VendNet TM 165 North 10 th Street Waukee, IOWA 50263-0488 United States of America September 2016 4223293 C TABLE OF CONTENTS FINAL ASSEMBLY... 1 FINAL
More informationDS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions
DS Plug-In Digital Signal Cross-Connect (PIX-DSX-) 9-Inch Shelf Kit Installation Instructions Contents Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications...2
More informationHARTING. Interface Connectors. People Power Partnership
11 4 HARTING Interface Connectors People Power Partnership People Power Partnership Quality Connections Worldwide HARTING was founded in 1945 by the family that still owns the company. Today, HARTING employs
More informationIOA Expansion Cabinet. Dual Line Cords Upgrade Instructions
IOA Expansion Cabinet Dual Line Cords Upgrade Instructions Notice The information contained in this document is subject to change without notice. STRATUS COMPUTER INC. MAKES NO WARRANTY OF ANY KIND WITH
More informationPage Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6
TC-SGRAH1-1005 October 05 R Series - High Efficiency Multi-position Air Handler Engineering and Specification Guide (Electric and No Heat) With optional field conversion downflow kit Contents: Page Number
More informationCabinet and wall-mounted case accessories
Cabinet and wall-mounted case accessories electronics PROTECTION 05/2016 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk PROLINE Content Cabinets...... 1 Main Catalogue Cabinet Accessories Overview Wall mounted
More informationRecommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC
Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC 10/16 Supplement to Installation & Operating Manual Any trademarks used in this manual are the property of their respective
More informationANZI Transfer Switch and Generator Wiring Installation Addendum
ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE
More information2O3D3-19A REVB MOUNTING
Practice Section 1672 Issue 6, September 2014 MOUNTING ETL LISTED CONFORMS TO UL STD 60950-1 CONTENTS Multiple Patents Pending CLEI Code SOM2300C, CPR 204577 PAGE 1 INTRODUCTION... 2 1.1 Reason for Reissue...
More information35 35A 50 50A 1 Single phase. Solid state power controller
Single Phase, Power Controller Single Phase, Power Controller Features Various and simple input specification DC4-2mA, 1-5VDC, External 24VDC External adjuster (1kΩ) External contact (ON/OFF) Various function
More informationFeatures and Benefits. Certifications
iologik 4000 Series Modular remote I/O Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin utility
More informationREMOTE POWERING Central Energy System ( HUB )
/ 0 REMOTE POWERING Central Energy System ( HUB ) User Guide Mitra E&I SCA Wavre Belgium 009 Subject to modifications without notice / 0 Content RECTIFIER SYSTEM - USER MANUAL The information and pictures
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationD-subminiature Backshells - Two-Piece D*H Series
Backshells - Two-Piece D*H Series Standard two-piece construction available in plastic, metallized plastic, or diecast zinc versions with 180 straight cable entry. Fits standard metal shell D-subminiature
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS OV310G MINI RACK OVEN ML-132515 OV310G A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43242 Rev. D (January 2018) F-43242 Rev. D (January
More informationCondenser Fan Pak Installation and Wiring Guide
Condenser Fan Pak Installation and Wiring Guide 2200IB1501 Make the most of your energy SM Condenser Fan Pak: Installation and Wiring Guide p The purpose of this document is to illustrate the recommended
More informationOutdoor Enclosure Power System ENC X100MP48F20-AC6
Outdoor Enclosure Power System ENC673034-1X100MP48F20-AC6 Manual MA015151A4 Issue 1 Nov 2010 Copyright 2010 Myers Power Products, Inc. Part# A015151A4 MA015151A4 Iss1 Page 1 of 24 Dimensions Outdoor Enclosure
More informationCPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A
CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A
More informationInstallation Instructions
Installation Instructions Part No. 50DJ902791 48/50FP,JP,MP,NP 50FPX,FPY,JPX,JPY 50FB,JB,NB Accessory Outdoor-Air Cfm Kit CONTENTS GENERAL........................................ 1 INSTALLATION................................
More informationVertical Cable Organizer with Finger Ducts - 0U - 3 ft.
Vertical Cable Organizer with Finger Ducts - 0U - 3 ft. Product ID: CMVER20UF This 3-foot vertical cable manager gives you a simple and space-efficient way to organize the cables in your server rack. You
More informationModel INT July 2010
/ STM-1 Multiplexer / Demultiplexer Model T-9691 26 July 2010 Intronics, Incorporated 2020 Lafayette Boulevard Fredericksburg, Va 22401 (540) 898-4518 (Voice) (540) 898-3603 (Fax) http://www.intrnx.com
More informationLow usage. Mild climate
III. R PSL-0 STEP-LIFT MAINTENANCE egular maintenance of the Ricon PSL-0 Wheelchair and Standee Step-lift is essential for optimum performance and will reduce the need for repairs. This chapter contains
More informationPROPORTIONAL VALVE TESTER. PVT-02 with 12 Pin Connectors
PROPORTIONAL VALVE TESTER PVT-02 with 12 Pin Connectors Paw-Taw-John Services, Inc. 18125 N. Ramsey Rd. Rathdrum, ID 83858 Phone: 208-687-1478 Fax: 208-687-4148 Email: info@pawtaw.com DESCRIPTION The Proportional
More informationSECTION 10 - ELECTRICAL
SECTION - ELECTRICAL Electrical Components, Upperstructure 6 6 TO CAB HARNESS BULKHEAD 9 WSH PWR WORK LT GND HEATER TEMP 6 CLUTCH-B CLUTCH-C 6 HORN 9 0 9 0 9 0 AC FAN- BOOM LTS TO UPPER PCB STR LEFT SGN
More informationCM52 Network Protector with Arc Flash Reduction Module
Contents Description Page 1: General.............................. 2 2: Maintenance Mode Settings.............. 2 3: Arming Maintenance Mode.............. 2 4: Remote Indicator....................... 2
More informationOPERATION MANUAL TALLY OPEN COLLECTOR UNIT HVS-TALOC. TALLY RELAY UNIT HVS-TALR (1 ST EDITION - Rev. 1) FOR-A COMPANY LIMITED
OPERATION MANUAL TALLY OPEN COLLECTOR UNIT HVS-TALOC TALLY RELAY UNIT HVS-TALR (1 ST EDITION - Rev. 1) FOR-A COMPANY LIMITED Precautions Important Safety Warnings [Power] Caution Operate unit only on
More informationHaemonetics MCS + (LN-9000) Parts List
Haemonetics MCS + (LN-9000) Parts List P. 1 P. 12a P. 3 P. 4 P. 5 P. 6 Chapter 5, Disassembly MCS+ 9000 Service Manual Weigher Arm 38397-00 for 7 valve device (110V) 48160-00 for 8 valve device (230V)
More informationGPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles MacDon M150 M200 PN: 602-0232-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully before installing or operating
More informationTDBU Series Dynamic brake unit user manual
Series Dynamic brake unit user manual Thank you for choosing TOPTEK s series dynamic brake unit. s are applied to absorb the motor regeneration energy when the three-phase induction motor stops by deceleration.
More informationPITNEY BOWES Sure-Feed Engineering SURE JET MODEL SJVB - TUV. Parts Manual. SJVB-TUVparts 1
SURE JET MODEL SJVB - TUV Parts Manual SJVB-TUVparts 1 TABLE OF CONTENTS SURE JET- SJVB-TUV SURE JET VACUUM BASE ASSEMBLY (FIG. 1)..... 5 FRAME ASSEMBLY (FIG. 2). 7 CONVEYOR DRIVE ASSEMBLY (FIG. 3).. 9
More informationTraining Bulletin New Model Introduction
GE Monogram GE Consumer Service Training Training Bulletin New Model Introduction October 2001/ TB-14-01 ZV950SDSS Wall-Mount Euro-Style High Performance Vent Hood Purpose To introduce the new wall-mount
More informationFATEK FB/FBs/B1/B1z Series
FATEK FB/FBs/B1/B1z Series Supported Series: FATEK FB/FBs/B1/B1z series, FB MC series, and FB MA series need FB-DTBR converter. Website: http://www.fatek.com/ HMI Setting: Parameters Recommended Options
More informationECS/ECD Wall Ovens. Bezel, Single Oven Bezel, Double Oven Door. Convection Cell. Non-Convection Inside Cell
ECS/ECD Wall Ovens Bezel, Single Oven Bezel, Double Oven Door Single Oven Non-Convection Inside Cell Double Oven Convection Cell Non-Convection Cell Inside Cell ECS - BEZEL SINGLE OVEN ASSEMBLY Ref# Description
More informationInstallation Guide Stainless Steel V-Track
Installation Guide Stainless Steel V-Track Thank you for selecting a DuctSox System. This guide will be helpful for the installation of a Stainless Steel V-Track System. Sections of fabric will be labeled,
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More informationDirectory chapter 08. InduCom Robust and EMI protected D-Sub interfaces
Directory chapter 08 Robust and EMI protected D-Sub interfaces New Page General information.............................................. 08.02 Mounting details................................................
More informationCPS2000 Cabinet Power System
Input (Nominal): 90 Vac to 264 Vac (Autoranging) Output (Nominal): -48 Vdc (up to 28.8 A) and Optional 50 VA Ringing Generator The low-maintenance, outside-plant CPS2000 (Cabinet Power System) integrates
More informationMultiGig RT Product Family Slot Pitch Density Data Rate RT lines/inch Gbps lines/inch Gbps RT lines/inch 6.50 Gbp
1 MultiGig RT Assembly! # # "$#! MultiGig RT Product Family Slot Pitch Density Data Rate RT1 0.8 113 lines/inch 3.125 Gbps 1.0 141 lines/inch 3.125 Gbps RT2 0.8 85 lines/inch 6.50 Gbps* 1.0 113 lines/inch
More informationSmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity
More informationJob Sheet 1 Electrical Panel Familiarization
Job Sheet 1 Electrical Panel Familiarization The Wind Turbine Training System: Electrical Pitch Hub hardware has an electrical enclosure that houses an electrical panel. As shown in Figure 1-1, this panel
More informationINSTRUCTIONS. Power Panel. Installation Instructions
Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL Document Number: 570-0049 Revision - 2-WIRE REMOTE SWITCH INTERFACE 455-0032 AND ELT INTERFACE 455-0041 INSTALLATION Artex Aircraft Supplies, Inc. 14405 Keil Road NE Aurora,
More informationPRELIMINARY. Ordering Part Numbers: Converter P/N: AX082600
Features: Acts as a DC/DC Converter or a Bidirectional Battery Charger Refer to Table 1.0 Inputs and Outputs 1 CAN port (SAE J1939) High efficiency Thermal protection for over temperature Reverse battery,
More informationElectric Furnace KF/KFS Series
Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt
More informationFast Orbit Feedback (FOFB) at Diamond
Fast Orbit Feedback (FOFB) at Diamond Guenther Rehm, Head of Diagnostics Group 29/06/2007 FOFB at Diamond 1 Ground, Girder and Beam Motion 29/06/2007 FOFB at Diamond 2 Fast Feedback Design Philosophy Low
More informationControl Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2018 ShopBot Tools, Inc. page 1 Table of Contents Introduction...5 Installation...5 Powering the PRSstandard Control Box...5
More informationHagie 264, 284XP, DTS8, 2100, 2101, DTS10 Installation Manual HG2
HG2 Hagie 264, 284XP, DTS8, 2100, 2101, DTS10 Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC4.5-BC-HG2-INST Rev A (Hagie 264, 284XP, DTS8, 2100,
More informationEVLA Front-End CDR. EVLA Front-End Budget
EVLA Front-End CDR EVLA Front-End Budget 24 April 26 1 EVLA Front-End Budget Overview 1) Budget Overview 2) Annual M&S Cost Estimates 3) Annual Manpower Cost Estimates 4) Annual Machining Estimates 5)
More informationG9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect
Two-Hand Controller -mm Wide Two-hand Control Circuit H Two-hand Controller, easy-to-connect Expansion Units available H Positive, force-guided contacts H DIN-rail mounting and panel mounting available
More informationTemposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors R-Series Models RP and RH Ethernet POWERLINK SENSORS Document Part Number 551191 Revision A Data Sheet Model RP Profile-style
More informationCOMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012
COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER
More informationIllustrated Parts List for VMAC System H E
Illustrated Parts List for VMAC System H00001-E 1 Main Assembly... 2 2 Inlet Valve and Compressor System, (90006 & P1002)... 3 Cooler Assembly 900069... 6 Manifold Assembly, 9000... 5 Tank Assembly, 900050...
More informationWall Oven Series -2. Parts List & Exploded Views. 30 Oven Contol Panel Parts List Single and Double Oven. 36 Oven Control Panel Parts List Single Oven
Parts List & Exploded Views Wall Oven Series - 0 Oven Contol Panel Parts List 6 Oven Control Panel Parts List Single Oven 8008 Control Head, 0, Sngl, Sst 800 Control Head, 0, Dbl, Sst 8006 Control Head,
More informationEVT A Memo 34. ig^la MONITOR AND CONTROL SYSTEM Monitor and Control Points. George Peck
EVT A Memo 34 ig^la MONITOR AND CONTROL SYSTEM Monitor and Control Points George Peck PROGRESS REPORT - March 12, 2002 This report summarizes the information gathered so far about monitor and control points
More informationFuse Box on the Roof 1500VDC
Fuse Box on the Roof 1500VDC ON BOARD FUSE BOX AND CONNEXION BOX FUSE BOX RANGE 750VDC - 1500VDC - 2000VDC FEATURES & BENEFITS For more than 50 years, Mersen have been providing the market with safe, reliable
More informationAir-insulated switchgear with
AIR-INSULATED SWITCHGEARS PIX 7 4 kv Air-insulated switchgear with vacuum switching devices Installation Operation Maintenance No. AMTNoT 060-0 Edition 03/009 Technical Manual AREVA T&D AREVA T&D Worldwide
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS OV300E MINI RACK OVEN ML-132155 OV300E A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43051 Rev. C (July 2017) F-43051 Rev. C (July 2017)
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationSuperpave Asphalt Binders
Superpave Asphalt Binders Aging and what they mean to the specification John D Angelo D Angelo Consulting, LLC johndangelo@dangeloconsultingllc.com Stiffness (Response to Load) elastic viscous elastic
More informationDART Charger Product Description, Information and Specification
g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY
More informationRADIATOR CLEANING OF RADIATOR
CO20 COOLING SYSTEM RADIATOR CLEANING OF RADIATOR Using water or a steam cleaner, remove any mud and dirt from the radiator core. CAUTION: If using a high pressure type cleaner, be careful not to deform
More informationPITNEY BOWES FLEXIBLE INK JET TRANSPORT 56 FIT BASE: FIT-56. Parts Manual. (BOM: FIT-56revA) FIT-56parts_rev0 1
FLEXIBLE INK JET TRANSPORT 56 FIT BASE: FIT-56 Parts Manual (BOM: FIT-56revA) FIT-56parts_rev0 1 VERSION HISTORY The table below summarizes the history of this document as it is published onto the company
More informationInteractive Balancing System
IBS 2000 Interactive Balancing System Parts Identification Manual Part No.: 9112388 HENNESSY INDUSTRIES INC. Manufacturer of AMMCO, COATS and BADA Automotive Service Equipment and Tools. Revision: 12/00
More informationMIL-DTL Series III Connectors
RELIABLE Self-locking threaded coupling 100% scoop proof Contact retention system provides excellent contact retention under severe vibration EMI PROTECTED Grounding fingers for excellent EMI protection
More information240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company.
240SS Power Unit Installation Manual AMKUS, Inc. is an ISO 9001 registered company. 4735 AMKUS, Inc., 2700 Wisconsin Avenue, Downers Grove, IL 60515-4226 Website: www.amkus.com E-mail: experts@amkus.com
More informationInfraStruXure PDU Power Cable
InfraStruXure PDU Power Cable Installation and Specifications 12AWG Power Cable with L21-20C Connector 10AWG Power Cable with L6-30C Connector 6AWG Power Cable with 3-pole, 4-wire, Grounding Connector
More informationControl Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2017 ShopBot Tools, Inc. page 1 Copyright 2017 ShopBot Tools, Inc. page 2 Table of Contents Introduction...5 Installation...5
More informationZIP LIGHT LED LUMINAIRE
LED LUMINAIRE INSTALLATION MANUAL Note: Follow the Electrical Codes of the Country where this fixture will be installed. For Canada follow the Canadian Electrical Code (CE) and for the United States follow
More informationWall mounted cases W
Overview..... 0 Cabinets...... 1 Main Catalogue Wall mounted cases W Wall mounted cases........ 2 Accessories for cabinets and wall mounted cases 3 Climate control 4 Desk-top cases 5 01505008 Subracks/
More informationMODEL SCA Installation and Operation Manual Important:
MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible
More information6K-SSR-RACK08. 8-solid state relay accessory board for use with PCI-DAS6000 Series and PCI-DAC6700 Series boards. User's Guide
6K-SSR-RACK08 8-solid state relay accessory board for use with PCI-DAS6000 Series and PCI-DAC6700 Series boards User's Guide Document Revision 2A, July, 2006 Copyright 2006, Measurement Computing Corporation
More informationINSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER
TO-161 073085 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER 6184-3..-.-.._. HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373
More informationMEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW
MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60
More information6K-SSR-RACK08 Specifications
Specifications Document Revision 1.1, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.
More informationHardi Europe AutoSlant DAH or DAH09 Installation Manual HD5
HD5 Hardi Europe AutoSlant DAH or DAH09 Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC4.5-BC-HD5-INST Rev B (Hardi Europe AutoSlant DAH or DAH09)
More informationEPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes
EPIC Hermetic Sealed DC and AC Contactor - 150+ Power Switching RoHS Compliant, all date codes File E320908 All contact ratings and coil versions may not be UL recognized. Contact GIGAVAC for a copy of
More informationENGINEERED TO ORDER SOLUTIONS
DM-Series ENGINEERED TO ORDER SOLUTIONS for Transformer Bushing, Winding Hot Spot and PD Monitoring Features & Benefits Advanced Analytics Flexible and Modular Hardware Platform Bushing Monitoring Optional
More informationSITESTAR ELECTRONICS CABINET DESCRIPTION
SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,
More informationPowercut Spare parts list. Edition Valid for serial no. 001-xxx-xxxx, 034-xxx-xxxx
Spare parts list Edition 20111010 Valid for serial no. 001-xxx-xxxx, 034-xxx-xxxx Ordering no. Product 0558 007 636 Powercut 1600, 400V 0558 007 637 Powercut 1600, 400V 25ft 0558 007 237 Powercut 1600,
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL DC FREE COOLING UNIT SYSTEM AIR CONDITIONER MODELS DAPA DLPA DAPA DLPA DAPB DLPB CONTROLLER MODELS LC00 LC0 LC000 Description Page Cabinet Components Exploded View... Usage List...
More informationPanduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF
Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF242430 and ZDF242430-6 Table of Contents Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation
More informationCV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY
CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY 1 TABLE OF CONTENTS 1.0 Specification 5 2.0 Installation 7 2.1 Rack Mounted 7 2.2 Cooling 7 2.3 Filament Module 8 2.4 Electrical Power Input 8 2.5 Grounds
More informationFuse / Circuit Breaker Panels
Critical Power from GE Micro-BDCBB DC Battery Distribution Circuit Breaker Bay Overview The GE Micro-BDCBB serves as a secondary power distribution center for +24Vdc or -48Vdc DC power delivered from a
More informationCabinet Control Unit (CCU) User Manual
www.akcp.com Cabinet Control Unit (CCU) User Manual Help Version updated till firmware 404n Copyright 2012, AKCess Pro Limited 1) Introduction What is the CCU? How to use this manual 2) Package Contents
More information