REMOTE POWERING Central Energy System ( HUB )

Size: px
Start display at page:

Download "REMOTE POWERING Central Energy System ( HUB )"

Transcription

1 / 0 REMOTE POWERING Central Energy System ( HUB ) User Guide Mitra E&I SCA Wavre Belgium 009 Subject to modifications without notice

2 / 0 Content RECTIFIER SYSTEM - USER MANUAL The information and pictures within this Manual is believed to be true at the time of publication however Mitra E&I accepts no responsibility to consequences from printing errors or inaccuracies. The information, pictures, drawings and specifications contained herein are subject to change without notice CHAPTER DESCRIPTI OF THE SYSTEM References Accessories not delivered with the basics systems... 6 CHAPTER MECHANICAL Packaging tbd Dimensions, weight tbd... 7 CHAPTER : ELECTRICAL General Environmental Information Safety of the system & assessments Input Outputs Up converters....5 Fan supply unit....6 Environmental conditions... CHAPTER.... Connections and Settings..... DC Input..... DC Line Output..... Alarm Output... 7 CHAPTER 5 INSTALLATI PROCEDURE... 0 Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

3 / 0 5. Rack mounting Grounding Convection cooling Fan cooling with fan unit Mounting or Replacement of the fan unit Mounting of one rack with fan unit Stacked mounting of racks with fan unit Mounting of ETSI brackets Mounting of the units Mounting and place of the units Fan Supply Unit Up converter Controller CEM Blank panel Connections Grounding Controller CEM Alarms Line Outputs DC Inputs Safety of the system & assessments... CHAPTER 6 USE OF THE SYSTEM Settings Normal operation Replacement of units Replacement DC/DC converter Replacement of the Controller CEM Replacement Fan Supply... 7 CHAPTER 7 SHORT FORM INSTALLATI MANUAL... 8 Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

4 / 0 7. General Safety Dimensioning of the Remote system Installation procedure and check list... 9 Table : references of the system... 5 Table : dimensions, weight... 7 Table : up converter specifications... Table : colour code Lex Multicable feeder... 6 Table 5 : alarm table - contacts... 8 Table 6 : alarm conditions... 5 Table 7 : overview Alarms - Leds... 6 Figure : Packaging box... 7 Figure : Front view 9 typ. configuration with fan tray... 8 Figure : DC/DC Up converter output characteristic... Figure : supply of fan tray... Figure 5 : DC input connector / alarms... Figure 6 : DC input cable & Ground... Figure 7 : Line output... 5 Figure 8 : Lex Multicable feeder... 5 Figure 9 : alarm connector... 7 Figure 0 : alarm cable... 9 Figure : convection cooling... 0 Figure : one rack with fan unit... Figure : stacked mounting of units with fan tray... Figure : ETSI mounting brackets... Figure 5 : Grounding... 7 Figure 6 : alarm outputs... 8 Figure 7 : alarm table system level... 9 Figure 8 : Line outputs... 0 Figure 9 : DC/DC output characteristic per line... Figure 0 : input DC external protection... Figure : Up converter... Figure : CEM0 controller... Figure : alarm status CEM0 removed... 7 Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

5 5 / 0 CHAPTER DESCRIPTI OF THE SYSTEM. References Reference & Ordering code CER8/00L0RFW-A CES8/06L0RFM-F CES8/L0RFM-F Description Basic system : HUB or Central Energy Rack without fan tray Basic System with fan tray, one monitor and 6 quad Up converters Basic System with fan tray, one monitor and quad Up converters Content Empty rack Dual DC input card CER8/00L0RFW-A : x CECL0 : 6x CEM0 : x CO89/50 : x CO89/5 : x blind panel : 7x CER8/00L0RFW-A : x CECL0 : x CEM0 : x CO89/50 : x CO89/5 : x blind panel : x CECL0 Quad Up converter Par 0 tbd CEM0 Monitoring for remote sites / up to lines per site CO89/5 Fan supply card CO89/50 Fan tray with supply cable CO89/5 Fan kit CO89/50 : x CO89/5 : x Blind panel for empty converter place ( box of 0 panels ) RP Lex Multicable feeder dual Communication mating connector Kit Alarm and DC input cables 0 panels with fixing screws 50 connectors -pole ETSI mounting kit bracket x spring washer M6 x washer M6 x M6x screw T0 x Table : references of the system Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

6 6 / 0. Accessories not delivered with the basics systems Note : these accessories are NOT part of the CES and CER systems described in the section.. The accessories have to be ordered separately. Ordering code Description Content Blind panel 0x Blind panel with fixing screw RP Lex Multicable feeder dual Communication mating connector 50 x -pole screw connectors DC Up pairs box 50 x tbd Kit Alarm and DC input cables x DC Input cables with connector x Alarm cable with connector ETSI mounting kit bracket x spring washer M6 x washer M6 x M6x screw T0 x No reference Grounding cable Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

7 7 / 0 CHAPTER MECHANICAL. Packaging tbd Paperboard Box : H x W x D ( 0 x 600 x 0 )mm tbd Weight typ. tbd kg Figure : Packaging box. Dimensions, weight tbd Unit W x H x D (mm) Weight (kg) Quantity Total (kg) Empty rack 9 without fan tray 8 x 67 x 7.9 tbd Empty rack 9 with fan tray 8 x x 7. tbd DC/DC UP converter 5 x 0 x Monitor card CEM0 5 x 0 x Fan control unit 5 x 0 x 5 0. Fan tray tbd tbd Total Max. Table : dimensions, weight Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

8 8 / 0 Figure : Front view 9 typ. configuration with fan tray Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

9 9 / 0 CHAPTER : ELECTRICAL. General.. Environmental Information The equipment that you bought has required the extraction and use of natural resources for its production. It may content hazardous substances for the health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end life equipment in a sound way. The crossed-bin symbol invites you to use those systems. If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste administration. 5 You can also contact us for more information on the environmental performances of our products... Safety of the system & assessments a) The voltage of the RFT-C circuit is 0 VDC. b) The effective line output capacitance of the Feeder is : - between the connection points for the conductor of the TELECOMMUNICATI NETWORK : typically 0nF - between the connection point for the one conductor of the TELECOMMUNICATI NETWORK and earth : typically nf c) At the time of installation, a system assessment shall be carried out to ensure that the effective capacitance of the total system, including the capacitance of the Feeder, does not exceed the values specified in EN Figure. d) At the time of installation, it shall be checked that the voltage rating of the wiring of the TELECOMMUNICATI NETWORK is adequate for the normal RFT-C CIRCUIT voltage ( 0VDC ) e) At the time of installation, it shall be checked that the circuits to be connected together are all RFT-C CIRCUITS. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

10 0 / 0. Input Input voltage : nominal 5V DC ( 0 7V DC ) Current : max. 0A ( DC/DC at 0V input ) Protections : breaker in each DC input UVP polarity ( each input has a series diode in the - DC Bus ) min typ. max Unit Notes Input Voltage Vdc UVP 0 Vdc Turn On : max. V Input current 0. Adc per converter at 5V converters per unit Input current 0.65 Adc per converter at 0V Total input current A Adc Total input current 0 A Adc at 5 V input and DC/DC units ( 56 lines ) at 6 V input and DC/DC units ( 56 lines ) Input protection 0 A Breaker in each DC input Temperature 0 +0 C Temperature tbd 5 C Convection cooling : temperature measured 0mm under the rack Fan cooling : Temperature of incoming air measured 0mm before the air inlet. Outputs DC out : Description : Lines out: Line cables : per line 0V DC / 58mA nominal current maximum 60mA the line DC circuit is a RFT-C voltage lines per Up converter up to 56 lines up to remote site per monitor card minimum rating of 0V DC Protections: see fig. leakage current <.5mA UVP 5V : current limitation is < 8mA down to 66V Open line : max. 50V and 58mA Communication : Alarms : Urgent ( U ) and Non-Urgent ( NU ) alarm contacts Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

11 / 0. Up converters One converter unit contents line converters of 8W Power : 8W per line converter Description min typ. max Unit Note Voltage 0 8 V dc Efficiency 8 85 % 5V, nominal load Current 58 ma dc per converter ( per unit ) Undercurrent 0. ma dc detection open pair tbd Open line voltage 50 V Open line current 58 ma dc UVP 5 V dc detection pair in short-circuit Leakage current 5 µa dc per converter Temperature C Screw terminal 0.05 mm² AWG Table : up converter specifications 8V 0V 5V 66V 60mA 50V 5 8mA 58mA : no load : nominal conditions : DC/DC in overload : UVP 5 : open line Figure : DC/DC Up converter output characteristic Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

12 / 0.5 Fan supply unit Important Warnings The Fan Cable must be immediately connected to the Fan card. There is a risk of overheating if the fan tray is not supplied when fixed under the Rack The Fan Card Front Connector ( RJ5 ) can only be used for Fan Tray supply and may NOT be used for Data Communication ( Ethernet, ) : The supply voltage ( x 0V DC 80mA ) for the fans is present on this RJ5 connector Figure : supply of fan tray Place the RJ5 immediately.6 Environmental conditions Temperature : C tbd with fan cooling C convection cooling Cooling : Fan cooling ( fan unit mounted under the rack ) Convection cooling Humidity : 5..95%RH, no condensation Environment : controlled Altitude (operating) 00m Maximum dissipation 50W Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

13 / 0 CHAPTER. Connections and Settings.. DC Input Connector Type on the Rack: Molex Mini-Fit, Sr Reference : 86-0 Connector Type for the client DC source : Molex Mini-Fit, Sr Female Reference : RP Lex 5V Input cable kit DC input cable with connector : x Alarm cable with connector Current : max. 0A at 0 V Protection : 0A breaker in each - DC line Wire: AWG 0 Polarity : protected for inverse polarity ( series diode ) INPUT UNIT DC INPUT DC INPUT DC INPUT COMM + OFF OFF 0A 0A Figure 5 : DC input connector / alarms Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

14 / 0... DC input cable Figure 6 : DC input cable & Ground See also table : RP Lex 5V DC Input cable part of the kit Length : m total Cross-section : AWG0 System side : Molex-mini-Fit pole Application side : pin tag AWG-0 Colour : : Negative = BLACK : Positive = RED.. DC Line Output * Connector : Connector Type on the Rack: PHOENIX MC.5/8 G -.5 ( ref:8 7 8 ) Connector Type for the client application : PHOENIX MC.5/8-ST -.5 ( ref : 8 0 ) Wire connection : screw terminals cross-section : AWG8.. 6 / mm² * Power : 8W per dc/dc up converter current : 58mA * Polarity: see fig. 7 the + and - are FLOATING * Protections : see fig. 7 Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

15 5 / 0 8V 0V Line Line 5V 66V 60mA Line Line 50V 5 8mA 58mA : no load : nominal conditions : DC/DC in overload : UVP 5 : open line Figure 7 : Line output... Line Output cable See also table : Figure 8 : Lex Multicable feeder RP Lex Multicable feeder dual Length : 6 m Cross-section AWG single strand the cable MUST be cut in the middle depending on the application System side : PHOENIX MC.5/8-ST -.5 Application side : no terminal Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

16 6 / 0 Colour : see table LEFT OF FEEDER/RIGHT OF BLOC RIGHT a b a b CP White blue C8P White blue CP White orange C8P White orange CP White green C8P White green CP White brown C8P White brown CP White grey C9P White grey CP red blue C9P red blue CP red orange C9P red orange CP red green C9P red green CP red brown a C0P red brown CP red grey C0P red grey CP black blue C0P black blue CP black orange C0P black orange CP black green CP black green CP black brown CP black brown CP black grey b CP black grey CP yellow blue CP yellow blue C5P yellow orange CP yellow orange C5P yellow green CP yellow green C5P yellow brown CP yellow brown C5P yellow grey CP yellow grey C6P white-blue blue CP white-blue blue C6P white-blue orange CP white-blue orange C6P white-blue green CP white-blue green C6P white-blue brown CP white-blue brown C7P white-blue grey CP white-blue grey C7P red-blue blue CP red-blue blue C7P red-blue orange CP red-blue orange C7P red-blue green CP red-blue vert Table : colour code Lex Multicable feeder Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

17 7 / 0.. Alarm Output * Connector Connector Type on the Rack: Mate-N-Lok pole male ( plug ) Connector Type for the client application : Mate-N-Lok pole female ( bush ) Reference housing : Reference socket ( x ) : ( for AWG 8 ) Cross-section : AWG8.. 0 / mm² See also table : RP Alarm cable part of the kit l : tbd Pin assignment: - : C = Common - : U = Urgent alarm - : NU = Non Urgent alarm DC INPUT DC INPUT NU OFF OFF U C ALARM CNECTOR Figure 9 : alarm connector Type alarm : Voltage free contacts Contact specifications : max. 7V dc / max. 0.A dc / resistive load Grounding : the Common of the alarm contacts is internally connected to the ground Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

18 8 / 0 Alarm table : OFF : system not under voltage : system in operation OFF No Al. NUA UA UA + NUA NUA UA C Coil NUA relay NUA NUA NUA NUA NUA Coil UA relay UA UA UA UA UA WITHOUT CEM 0 Coil relay : RED = activated WITH CEM 0 Table 5 : alarm table - contacts Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

19 9 / 0... Alarm cable Figure 0 : alarm cable See also table : RP Alarm cable part of the kit Length : m Cross-section AWG single strand System side : Mate-N-Lok -pole Application side : no terminal Colour : Terminal Colour Alarm description colour Common colour Urgent colour Non Urgent Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

20 OFF OFF 0 / 0 CHAPTER 5 INSTALLATI PROCEDURE 5. Rack mounting 5.. Grounding The rack has to be connected to the ground ( bonding ) via its metal housing The grounding has to be in accordance with the local rules and specifications. See section 5. for the details 5.. Convection cooling Temperature : maximum +5 C tbd 9" (8 mm) U or 5mm minimum free distance mm or U R R R R CAN H CAN L CAN H CAN L R F A N Alarm FANSUPPLY R R R U or 5mm 0 mm Grounding frame Chassis Support - required C onvection co olin g Figure : convection cooling Ambient temperature measured 0mm under rack Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

21 OFF OFF CAN H CAN L CAN H CAN L / Fan cooling with fan unit 5... Mounting or Replacement of the fan unit Required material : see table CO89/5 Fan kit CO89/50 : x CO89/5 : x Description Material Picture Rear of the rack, remove two combi-screws Mx8 Torx T0 Place the fan unit Fix the unit with the two combi-screws Mx8 Remove the most right blind panel and place the fan supply card Connect the fan unit with the fan supply card R R R R R R R R F AN Alarm FANSUPPLY When the Fan tray is installed, the Fan Cable must be immediately connected to the Fan card. There is a risk of overheating if the fan tray is not supplied when fixed under the Rack The Fan Card Front Connector ( RJ5 ) can only be used for Fan Tray supply and may NOT be used for Data Communication ( Ethernet, ) : the supply voltage ( x 0V tbd DC 80mA ) for the fans is present on this RJ5 connector. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

22 OFF OFF / Mounting of one rack with fan unit 9" (8 mm) minimum free distance for cooling ( air circulation) U or 5mm mm or U R R R R CAN H CAN L CAN H CAN L R F A N Alarm FANSUPPLY R R R Grounding frame U or 5mm Chassis Support - required U AIR FLOW FRT 50 mm 0 mm Minimum free space for cooling Ambient temperature : temperature of the incoming air measured 0mm from the air inlet Figure : one rack with fan unit Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

23 / Stacked mounting of racks with fan unit AIR FLOW FRT 0 mm AIR FLOW FRT 50 mm 0 mm Minimum free space for cooling Ambient temperature : temperature of the incoming air measured 0mm from the air inlet FAN TRAY :CO 89/50 Figure : stacked mounting of units with fan tray The distance between the racks can be defined by the dimension of the fan tray mounted on the rack. The ambient temperature of each individual rack is the temperature of the incoming air measured 0mm from the air inlet. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

24 / Mounting of ETSI brackets Reference of the kit : Width : rack is delivered for 9 mounting rack is also designed for ETSI mounting accessories for ETSI mounting can be added Free space top and rear : see figure ETSI bracket See table for content of the kit Figure : ETSI mounting brackets Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

25 5 / 0 5. Mounting of the units On delivery : rack for 9 empty rack Settings must be done by the user. All connections are on the front of the system and are accessible without any dismantling. 5.. Mounting and place of the units Except the input unit ( most left ), all other units ( Up converters, controllers, Fan Unit ) have NO fixed place. In total 5 units can be mounted in the rack. For Safety reason, the empty places must be protected by a blind panel. 5.. Fan Supply Unit Indications : Red Led Alarm one or more fan in failure Green Led On unit is operating Advised location : most right place as this unit have no direct relation with all other units Hot pluggable Connection with the fan tray : RJ5 on the front panel FAN SUPPLY Not for data Communication The Fan Card Front Connector ( RJ5 ) can only be used for Fan Tray supply and may NOT be used for Data Communication ( Ethernet, ) : the supply voltage ( x 0V tbd DC 80mA ) for the fans is present on this RJ5 connector. When the Fan tray is installed, the Fan Cable must be immediately connected to the Fan card. There is a risk of overheating if the fan tray is not supplied when fixed under the Rack Fixed by two screws Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

26 6 / Up converter One up converter unit has up converters Hot pluggable Open line voltage : max. 50V DC Nominal values : voltage : 0V DC current : 58mA power : 8W Indications : one green Led per up converter Setting : dip-switch one position per converter Place : no dedicated place but for a better understanding of the application, it is recommended to place the converters of a same Remote site close to each other and close to the controller which monitor the site Fixed by two screws 5.. Controller CEM0 No dedicated place in the rack Recommended : place the controller as close as possible to the up converter unit for the relevant sites For details of the settings : refer to section tbd Up to controller per rack : one Master and three Slaves One controller : can monitor up to Remote sites Hot pluggable The system will continue to work without controller but alarms and defaults are no more detected Indications : one green Led per Remote site Fixed by two screws 5..5 Blank panel For Safety reason, the empty places must be protected by a blind panel. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

27 7 / 0 5. Connections 5.. Grounding The grounding cable is NOT delivered with the system Requirements : colour : yellow/green cross-section : mm² - length : terminal : M5 cable terminal which can be fixed on the left side of the rack, see figure 5. This cable MUST be connected to the frame containing the system Yellow/ Green Stud M5 : M5 Earth washer : M5 cable terminal : spring washer : M5 nut Stud M5 on the system Figure 5 : Grounding 5.. Controller CEM0 R R R R Twisted pair coming from the controller of the corresponding remote site CAN H and CAN L : will be required when the Comp@s communication is used Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

28 8 / Alarms The alarm cable is NOT delivered with the system Alarm connector is hot-pluggable Type of alarm contacts : the contacts are CLOSED when the corresponding alarm is present. Important : as normally open contacts are used, a bad contact, a missing connection or a removed connector will NOT give any alarm The common is internally connected to the ground = 0V DC DC INPUT DC INPUT NU OFF OFF U C ALARM CNECTOR The C ( Common ) is internally connected to the ground ( 0V DC ) Figure 6 : alarm outputs Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

29 9 / 0 OFF : system not under voltage : system in operation OFF No Al. NUA UA UA + NUA NUA UA C Coil NUA relay NUA NUA NUA NUA NUA Coil UA relay UA UA UA UA UA WITHOUT CEM 0 Coil relay : RED = activated WITH CEM 0 Comments : Figure 7 : alarm table system level. Without controller CEM0 the alarm contacts are as given by the fig. 7 and these contacts are not monitored by the controller : this is a fixed configuration. The Urgent Alarm will be closed if the DC supply of the system is absent.. System with CEM0 and NO alarm : contacts UA and NUA are OPEN 5.. Line Outputs Total available slots = 5 Up to Remote sites ( ROP ) can be connected to one Controller CEM0 of the Central Office rack. Up to ( one Master and three Slaves ) controllers can be used in one rack Each Up converter unit has four converters Each line can deliver : 58mA and max. 8W The available power at the end is depending on the losses between the up and the down converter. Controller Remote sites Fan Y / N Available slots for up converters Max lines Up to N 56 Up to Y 5 Up to 8 N 5 Up to 8 Y 8 Up to N 8 Up to Y Up to 6 N Up to 6 Y 0 0 Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

30 OFF OFF 0 / 0 R R R R CAN H CAN L F A N Alarm CAN H CAN L R FANSUPPLY R R R Figure 8 : Line outputs WARNING : Once in operation and when a loaded pair is connected, a DC HIGH VOLTAGE ( 0V ) is present on the Line Output connectors. The maximum current is 58mA. If the line is not connected to the output of the up converter or if the line is open, the voltage is automatically reduced to typ. 50V. The maximum current is 58mA. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

31 / 0 8V 0V Line Line 5V 66V 60mA Line Line 50V 5 8mA 58mA : no load : nominal conditions : DC/DC in overload : UVP 5 : open line Figure 9 : DC/DC output characteristic per line 5..5 DC Inputs Description with the delivered input cables The input unit has two identical inputs : and but the system can operate with only one input. Input protections : maximum current : polarity : UVP : Nominal voltage : breaker of 0A protected against wrong polarity by a series diode in the negative line 0V DC - 5V ( 0.. 7V ) + is the common line IMPORTANT : for Safety requirements, the + MUST be connected to the earth by the user WARNING An external disconnect and protection device F must be provided by the end-user This device F MUST be placed in the NEGATIVE DC line. Value : 0A < F < 0 A / 7V DC, recommended value : A Even if the two inputs A & B are used, both DC lines must be protected by the same protection device of 0A < F < 0 A / 7V DC, recommended value : A Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

32 / 0 A DC source > 0 A + - DC INPUT OFF OFF B DC source > 0 A + - Figure 0 : input DC external protection 5..6 Safety of the system & assessments f) The voltage of the RFT-C circuit is 0 VDC. g) The effective line output capacitance of the Feeder is : - between the connection points for the conductor of the TELECOMMUNICATI NETWORK : typically 0nF - between the connection point for the one conductor of the TELECOMMUNICATI NETWORK and earth : typically nf h) At the time of installation, a system assessment shall be carried out to ensure that the effective capacitance of the total system, including the capacitance of the Feeder, does not exceed the values specified in EN Figure. i) At the time of installation, it shall be checked that the voltage rating of the wiring of the TELECOMMUNICATI NETWORK is adequate for the normal RFT-C CIRCUIT voltage ( 0VDC ) j) At the time of installation, it shall be checked that the circuits to be connected together are all RFT-C CIRCUITS. Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

33 / 0 CHAPTER 6 USE OF THE SYSTEM General : only qualified Service Technicians, aware of the hazards involved, can have access to the wires / cables of the Remote Feeding Circuits 6. Settings Normal operation 6.. DC/DC Up converter * DC/DC Up converters : Four Green Leds ( ) on each converter are ACTIVE line The connected and used lines must be activated by setting the corresponding dip-switch in the position. NOT USED Outputs The not used lines must be inhibited by setting the corresponding dip-switch in the OFF position. The output is OFF and the Alarm is inhibited. When the output is OFF, the output voltage is 0V Position slider to the right Position slider OFF to the left Figure : Up converter Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

34 / Controller CEM0 R R R R CAN H CAN L CAN H CAN L Green Led : controller Green Leds : Remote Sites R... R CAN Communication Ports R R R R Communication Ports with the Remote sites R.. R Figure : CEM0 controller Remove the Controller to have access to the settings Settings with the dip-switches S70 and S70 S70 : one controller present : Master more then one controller preset : only E Master, the other as Slave S70 (.. 5 ) : no function (when the CAN communication is not used ) S70 6 : without CAN : OFF with CAN : S70 (.. ) : one controller can receive the alarm signal from max. remote sites. when the alarm pair from the remote site is connected, place the corresponding switch in the position S70 5 : Alarm Configuration for the UA ( Urgent alarm ) alarm in more than one unit ( DC/DC, fan ) OFF more than one DC/DC converter alarm in the same unit Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

35 5 / 0 6. Overview alarms on system level Failure Urgent Al Non-Urgent Al Possible causes line fail X open line > line fail X line overloaded asymmetrical Line load DC/DC fail X DC/DC unit fan fail X > fan fail X Defect fan Defect fans Defect fan unit Table 6 : alarm conditions Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

36 6 / 0 Explanation CEM0 DC / DC.. FAN Status Led LED Leds Statu s No DC Cause Unit defect Led.. Status Cause Leds Alarm/ On DC/DC Alarm set = off On Status Cause Unit defect or no DC OFF R Unit OK Site not set No alarm Alarm open line OR line overload OR asymmetrical line load Alarm On Alarm No Alarm Alarm U > fan fail R Site OK R Site NUA Blinking R Site UA Alarm Alarm N U fan fail R Com m lost R Com m Conf ig error Table 7 : overview Alarms - Leds Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

37 7 / 0 6. Replacement of units 6.. Replacement DC/DC converter If defect, the DC/DC unit can be removed from the rack during operation. Procedure : IMPORTANT : if a DC/DC is removed from the system for a longer time ( more than hours ), the empty location MUST be filled in with a blind panel ; reference : After replacement, set the dip switches of the front-plate in the correct position : OFF connected and used line non used line 6.. Replacement of the Controller CEM0. If defect, the CEM0 unit can be removed from the rack during operation. When the unit is removed, the alarm contacts are : System in operation No Alarm NUA UA C Coil NUA relay NUA Coil UA relay UA Coil relay : RED = activated WITHOUT CM 0 Figure : alarm status CEM0 removed. Place the dip-switches in the same position as on the replaced unit. Place the unit and fix it.. Replacement Fan Supply See 5.. If defect, the fan supply unit can be removed from the rack during operation. Important Warning When the Fan supply is removed, the new unit must be immediately replaced and the fan tray connected to the Fan card. There is a risk of overheating if the fan tray is not supplied when fixed under the Rack Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

38 8 / 0 CHAPTER 7 SHORT FORM INSTALLATI MANUAL 7. General 7.. Safety The output voltage of the RFT-C circuit is 0 VDC. Refer to the section Dimensioning of the Remote system The number of required pairs is depending on the following parameters :. Power of the Remote site. Length of the pairs between the Central office and the Remote site. Cross-section of the cupper pairs. Required redundancy For a complete calculation of the system, please contact your Local Mitra E&I Sales Organization or the Headquarter of Mitra E&I : mail@mitra-ei.com or Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

39 OFF OFF OFF OFF CAN H CAN L CAN H CAN L R R R R CAN H CAN L CAN H CAN L R R R R F A N Alarm 9 / 0 7. Installation procedure and check list Step Action Comment Picture Refer to F AN Alarm. Mount the an If not 5... R R Tray under the mounted R R rack on delivery Done or OK R FANSUPPLY R R R. Mount the ETSI brackets 9 on delivery, ETSI is optional 5... Place the chassis support in the cabinet. Place and fix the rack 5. Connect the frame to the chassis ground (bonding) 6. Place the Fan supply unit 7. Make the connection between Fan Tray and the Fan Supply Unit ( RJ5) 8. Mount the required Converter units 9. Mount the required CEM0 unit(s) 0. Mount blind panels in the empty slots Most right position Calculation of the required number of lines : refer to 7.. minimum free distance for cooling ( air circulation) Grounding frame U or 5mm mm or U U or 5mm Chassis Support - required FANSUPPLY 5.. or & & 5.. & Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

40 0 / 0 Step Action Comment Picture Refer Done or OK to. Open the Input DC INPUT DC INPUT 5..5 breaker(s). Place the DC 5..5 Input connector(s) NU. Place the 5..5 OFF OFF U Alarm connector C. Determine the lines configuration 5. Connect the lines to the Up converters 6. On the Up converter : activate the connected line(s) ALARM CNECTOR Position slider to the right Position slider OFF to the left Settings on the CEM0 8. Settings on the CEM0 9. Settings on the CEM0 Master or Slave Alarm config Remote site Connect the Communication line(s) on the CEM0. Connect all lines to the corresponding Up converters. Switch the DC input(s) The system is operational if the Remote Site is connected to the Central Office system through the dedicated pairs Remote Power with Monitor Customer Support Edition 0 Wavre Belgium January 009

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Installing and Removing Power Supplies

Installing and Removing Power Supplies Power Supply Overview, page 2 Installing Power Supplies, page 3 Removing Power Supplies, page 8 Finding the Serial Number, page 9 1 Power Supply Overview Power Supply Overview You can install two types

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP Warning for Your Protection 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings.

More information

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC Warning for Your Protection 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00 TECHNICAL MANUAL EN Inverter / Charger Combi Combi SW 12V 1600VA Réf : PF.16088 Combi SW 24V 3800VA Réf : PF.16089 SAFETY PRECAUTIONS TO PREVENT ANY RISK OF ELECTRIC SHOCK OR FIRE, READ THIS MANUAL CAREFULLY

More information

Power and Cooling. Chassis Power System

Power and Cooling. Chassis Power System This chapter describes the Cisco NCS 6000 Series Routers power and cooling systems. It also provides the power, grounding, and cooling requirements for the installation site to help you plan the site facilities

More information

AWZ 110. AWZ 13,8V/1A/7Ah/LM

AWZ 110. AWZ 13,8V/1A/7Ah/LM AWZ 110 v.1.3 AWZ 13,8V/1A/7Ah/LM Linear buffer power supply unit Grade 2. EN* Edition: 9 from 02.11.2017 Supercedes the edition: 8 from 23.01.2017 GREY POWER plus Features: EN50131-6 compliance, 1 2 grades

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

SCCP PWM Charge Controller/Load Manager Owner s Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual SCCP05-050 PWM Charge Controller/Load Manager Owner s Manual NOTE: Follow instructions in order. Charge batteries at least once a week. Use reducers to connect larger wires disconnect to terminals. battery

More information

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from v.1.0 PSUPS 13,8V/12V/10A/17Ah Buffer power supply for 8 HD cameras and recorder EN Edition: 2 from 15.11.2017 Supercedes the edition: 1 from 23.05.2017 GREEN POWER CCTV Features: DC 13,8V uninterruptible

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER Important The BBC -3140 must be used according to the local safety standards with the particular application. All wiring and connections

More information

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual ADCP-80-580 Issue 3 11/2010 17943-A Circuit Breaker for ±24 or ±48 Vdc 1474485 Rev C Preface COPYRIGHT

More information

ThunderION. Static Neutralising System. GB User's Manual 2

ThunderION. Static Neutralising System. GB User's Manual 2 ThunderION SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon +31-(0)573-288333 Telefax +31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08 Installation Guide Table of Contents 1.1 Overview... 2 1.2 Specifications... 3 1.3 Inspection... 3 1.4 Installation... 4 1.4.1 Important Installation

More information

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE v.1.0 PoE 27,6V/4x0,4A/2x7Ah/PoE Buffer switch mode power supply unit EN* Edition: 2 from 16.09.2013 Supercedes the edition: 1 from 06.02.2012 Features: DC 27,6 V/4x0,4A uninterruptible power supply fitting

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part# Installation Manual AC Edge Split Phase 60 A (6/6) AC Power Distribution Unit AC Edge Model AC60DF 6/6 Part# 1101-1071 1402-036 RevE Installation Manual AC Edge Table of Contents AC Edge Introduction 3

More information

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC PSBSH 2012B v.1.2 PSBSH 13,8V/2A/7Ah/HERMETIC Buffer switch mode power supply unit, EN** Edition: 7 from 02.11.2017 Supercedes the edition: 6 from 08.06.2017 Features: DC 13,8V/2A uninterruptible power

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

LAN Power Supply Module.

LAN Power Supply Module. Revision 1.1 Sept. 2002 1 Contents Model 3000 / Access 4000 LAN Power Supply Module. Standard: P/N: 995050 Enhanced: P/N: 995050ENH INSTALLATION MANUAL Overview... 1 System Requirements and Reporting...

More information

30A SMART ENERGY MANAGEMENT SYSTEM TM

30A SMART ENERGY MANAGEMENT SYSTEM TM 30 Amp EMS Display Panel P/N 00-00903-030 (Black) 30 Amp EMS Distribution Panel P/N 00-0091-000 CAUTION The 30A SMART EMS is a centralized power switching, fusing, and distribution center. Power from the

More information

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual Power :: 600CB10 and 600CB12 User Manual 600CB10 - Front View 600CB10-C - Rear View Applies to : 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C :: 600CB12-VL :: 600CB12-CL Table

More information

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel Model 009-8004-0100N Installation Guide, Part Number 123759-3 Copyright 2011, Telect,

More information

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016 PSU features. Compliant with the requirements of the

More information

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Quick guide. Plug-in fans GPPM with FC101_106 August 2014 Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors

More information

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet Combined Power Supply & Battery Charger Data Sheet INTRODUCTION UCS-CHR24V55W is a combined charger and power supply with dedicated outputs for both charging and power supply. With a large input range

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

Warmbier Germany, Wrist Strap & Footwear Combo Tester

Warmbier Germany, Wrist Strap & Footwear Combo Tester ESD Safe Warmbier Germany, Wrist Strap & Footwear Combo Tester Warmbier Model PGT120, reliable & caring since 1976 The personnel Grounding Tester PGT 120 is a wrist strap and footwear tester for access

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family TPM Fuse Panel Installation Guide Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...

More information

User Manual. SP10000 Premium

User Manual. SP10000 Premium User Manual Solar Hybrid 3Phase PV Inverter SP10000 Premium Version: 1.2 Table Of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 3-1. Packing List... 4 3-2.

More information

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise Silver T E L E C O M V2.0 Aug 2008 Pb. Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 4mm (H) Low output ripple and noise Input voltage range 36V to 57V Only one low cost external decoupling

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed

More information

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power Silvertel V.3 April 207 Datasheet Pb Features IEEE802.3at and IEEE802.3af compliant Maximum 30W peak output power Small Single In-Line (SIL) package size 57.3mm (L) x 4mm (H) Overload, short-circuit and

More information

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel Model 009-8005-0404 Installation Guide, Part number 123518-6 Copyright 2010,

More information

ORVALDI Solar Infini 5kW

ORVALDI Solar Infini 5kW ORVALDI Solar Infini 5kW User manual Version: 1.0 Table Of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5 5. Grid (Utility) Connection...

More information

AWZ 200. AWZ 13,8V/2A/7Ah/L

AWZ 200. AWZ 13,8V/2A/7Ah/L GREY POWER AWZ 200 v.2.4 AWZ 13,8V/2A/7Ah/L Linear, Buffer Power Supply Unit EN** Edition: 7 from 15.05.2014 Supercedes the edition: 6 from 13.02.2014 Features: 13,8VDC/2A uninterruptible supply fitting

More information

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve) Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

User Manual. Hybrid 4KW PV Inverter. Version: 1.2

User Manual. Hybrid 4KW PV Inverter. Version: 1.2 User Manual Hybrid 4KW PV Inverter Version: 1.2 Table of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5 4. Grid (Utility) Connection...

More information

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from PSDCB161220E v.1.0 PSDCB 13,8V/20A/16x1A/65Ah Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 24.04.2017 GREEN POWER CCTV Features: DC 13,8V/20A

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

USER MANUAL ONLINE UPS

USER MANUAL ONLINE UPS USER MANUAL ONLINE UPS 1-3K/220Vac LCD Uninterruptible Power Systems Please comply with all warnings and operating instructions in this manual and on the unit strictly. Save this manual properly. Do not

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

Features. Description. Table of Contents

Features. Description. Table of Contents Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating

More information

Manual for Inverter system type PCI05

Manual for Inverter system type PCI05 - 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause

More information

CPS Energy Balancer. Version: 1.0

CPS Energy Balancer. Version: 1.0 CPS Energy Balancer Version: 1.0 CHINT POWER SYSTEMS AMERICA CO., LTD. Address: 700 International Parkway, Suite 102 Richardson, Texas Zip Code: 75081 Web: www.chintpower.com/na Email: americasales@chintpower.com

More information

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Pure Sine Wave Inverter GP-HS1500. Owner s Manual Pure Sine Wave Inverter GP-HS1500 Owner s Manual 2 Table of Contents Introduction 3 Specifications 4 Name and Main Function 5 Installation 7 Operation 9 Operating Limits 13 Troubleshooting 13 Maintenance

More information

i-energy i-micro inverter GT260

i-energy i-micro inverter GT260 i-energy i-micro inverter GT260 This installation guide contains important instructions on safety matters and the installation of the i-energy i-micro inverter GT260. Please read this guide carefully and

More information

CBM-105FN/FP Circuit Board

CBM-105FN/FP Circuit Board CBM-105FN/FP Circuit Board Features Adjustable acceleration and deceleration time (0 to 2.5s) Stable speed operation Manual or automatic recovery of the thermal overload device One (1) rotary switch to

More information

OPTI-Solar SC MPPT Series

OPTI-Solar SC MPPT Series www.opt i -sola r. c o m OPTI-Solar SC MPPT Series SOLAR CHARGE CONTROLLER SC-50 / SC-80 / SC-80X / SC-160X MPPT Installation and Operation Manual CONTENTS Introduction... Feature... Specification... Dimension...VII

More information

Installing the Switch Chassis

Installing the Switch Chassis Safety, page 1 Installation Options with Racks and Cabinets, page 2 Airflow Considerations, page 2 Installation Guidelines, page 2 Unpacking and Inspecting the Switch, page 3 Installing the Switch, page

More information

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the

More information

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00 Growatt 10000HY Installation & Operation Manual GROWATT NEW ENERGY TECHNOLOGY Co.,LTD No.28 Guangming Road, Shiyan, Baoan District, Shenzhen, P.R. China T F E W + 86 755 2747 1900 + 86 755 2747 2131 info@ginverter.com

More information

Demarcation Fuse Alarm Panel

Demarcation Fuse Alarm Panel Installation Guide Applies to: 009-7001-0104 & 009-7001-0104-TFD Table of Contents 1.1 Overview...3 1.2 Inspection...3 1.3 Specifications...4 1.4 Installation...5 1.4.1 Important Installation Guidelines...5

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

LED/Switch Modules Installation Instructions

LED/Switch Modules Installation Instructions LED/Switch Modules Installation Instructions Introduction This publication describes the installation procedure for the 4100-1288 LED/Switch Controller Card and the associated 4100-1275 to 1278, 4100-1280

More information

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking. GV-4 Manual Solar Charge Controller with Maximum Power Point Tracking For models: GV-4-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded http://genasun.com Genasun Inc. 1035 Cambridge st. Suite 16B Cambridge,

More information

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function. User Manual Design Features: 1. PFC function. except BC-1215HT / BC-2407HT 2. LCD remote control. BC-1215HT / BC-2407HT 3. Battery temperature sensor function. 4. Tri-LED color indicator for different

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller

More information

MASS COMBI 12/ (120V), 12/ (120V), 24/ (120V), 24/ (120V)

MASS COMBI 12/ (120V), 12/ (120V), 24/ (120V), 24/ (120V) USERS MANUAL MASS COMBI 12/2500-100 (120V), 12/4000-200 (120V), 24/2500-60 (120V), 24/4000-100 (120V) SINE WAVE INVERTER/CHARGER COMBINATION WITH GENERATOR / MAINS SUPPORT MASTERVOLT Snijdersbergweg 93,

More information

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter Silvertel V.0 May 2009. Features Pb IEEE802.3at compliant Maximum 30 Watt Output Power High efficiency DC/DC converter Wide adjustable output voltage range 500Vdc isolation (input to output) Input voltage

More information

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12 miconverter 18-Module Rack-Mount Power Chassis User Manual Page 12 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 General and Copyright Notice This publication is protected by

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 DC/DC converter with SFB technology, primaryswitched, input: 24 V DC, output: 48 V DC, output current: 5 A Data sheet 104793_en_01 PHOENIX CONTACT 20130503 1 Description QUINT DC/DC converter maximum system

More information

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Manual. BlueSolar Grid Inverter 1500 / / / / / 230 Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

PowerScale kva Technical Specifications

PowerScale kva Technical Specifications PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

TPM/GMT Panel Installation Guide

TPM/GMT Panel Installation Guide TPM/GMT Panel Installation Guide Document INS-837xxxxxxx This manual covers the following part numbers- Trimm 837xxxxxxx Family Table of Contents Table of Contents... 2 Section 1- General Information...

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0 Guide to Paux System for Motor Caravans 006-007 Model AS PAUX v..0 PauX System Instructions ArSilicii Rel..0 Cautions The material contained herein is the property of ArSilicii S.r.l. and may not be reproduced

More information

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L224-48V to +24V, L225 +24V to -48V Edge Controller example Outputs RTNs Inputs RTNs Refer to Infinity Converter Brochure

More information

LINE CONDITIONERS USER'S GUIDE

LINE CONDITIONERS USER'S GUIDE LINE CONDITIONERS USER'S GUIDE PE 1411/10 (9415 014 11 101) PE 1412/10 (9415 014 12 101) PE 1413/10 (9415 014 13 101) PE 1411/15 (9415 014 11 151) PE 1412/15 (9415 014 12 151) PE 1413/15 (9415 014 13 151)

More information

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

PowerScale TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation

More information

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS until reading through this manual carefully. Observe

More information

EMERGENCY VEHICLE BATTERY MANAGER PS2024

EMERGENCY VEHICLE BATTERY MANAGER PS2024 EMERGENCY VEHICLE BATTERY MANAGER PS2024 2 The PS2024 (Fig. 1) is designed as a on-vehicle battery charger / battery charge state monitor. While the vehicle is at its base or station, the charger is connected

More information

SITESTAR ELECTRONICS CABINET DESCRIPTION

SITESTAR ELECTRONICS CABINET DESCRIPTION SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3

More information

Table of Contents 1 SYSTEM OVERVIEW GENERAL ARRANGEMENT AND OPERATION INSTALLATION MECHANICAL INSTALLATION 7

Table of Contents 1 SYSTEM OVERVIEW GENERAL ARRANGEMENT AND OPERATION INSTALLATION MECHANICAL INSTALLATION 7 2016 TECHNICAL DOCUMENTATION WILHELMSEN SHIPS SERVICE MARINE CHEMICALS - WATER SOLUTIONS WILHELMSEN SHIPS SERVICE AS Strandveien 20, N-1324 Lysaker, Norway Table of Contents 1 SYSTEM OVERVIEW... 3 2 GENERAL

More information

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02 1/16 Operators and Maintenance Manual Display EEM MOT 01 FE02.02 Rev. 01 December 2017 2/16 Table of Contents Introduction... 3 1. General information... 3 2. Handling in transport and storage... 4 3.

More information