240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company.

Size: px
Start display at page:

Download "240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company."

Transcription

1 240SS Power Unit Installation Manual AMKUS, Inc. is an ISO 9001 registered company AMKUS, Inc., 2700 Wisconsin Avenue, Downers Grove, IL Website: Tel.(630) Fax (630)

2 Installation Procedures 1. Remove the unit from the packing cartons and carefully inspect for damage. Damage that occurs during shipment should be reported immediately to the carrier. 2. There are 4 major components included in the 240SS Super Simo Power Unit. 1. Remove the black cover from the power unit by removing the bolts on either end of the unit. 2. Determine the location for the power unit. Make sure the black cover is accessible so it is able to be removed for service. The sight gauge should be accessible for service as well. A template is provided to assist in marking the location of the mounting holes. 1. VFD (Variable Frequency Drive) Panel 2. Control Panel 3. Heat Exchanger 4. Power Unit Optional Wireless Receiver 3. The power unit has been shipped with the kinetic bushings and mounting brackets installed. A 2X4 is used between the mounting brackets to prevent them from spreading. Heat Exchanger VFD Panel Control Panel 4. Install and tighten the 4 mounting bolts. Power Unit Installing the 240SS Power Unit Remove bolt Remove bolt Sight Gauge 5. Remove the 4 bolts securing the 2X4 from each end of the 2X4. Remove the 2X4 and discard. Wiring Instructions Please refer to the following diagram for wiring instructions. Please note that each cable has a matching cable and plug. Do not remove or alter any connections. Each connector has one matching mate. 1

3 PIN DEUTSCH (DT) 2 EH-EX EH-SK100 PC-FD200 PC-FD300 EH-FD200 MA 3 PIN WEATHERPACK C410 M F OPTIONAL C720 EH-EX C610 R P PC-FD310 C620 P R OPTIONAL MA C510 F M HOT LOW OIL OIL PC-EK100 (-) PC-EK100 (+) C500 EH-EX R P 2 PIN DEUTSCH (DTP) C710 C130 PC-FD210 O - OFF O - OFF O - OFF O - OFF Note: Each cable has a matching cable and plug. Do not remove or alter any connections. Each connector only has one matching mate. PC-FD100 L1 = BLACK L2 = WHITE GND = GREEN 60 AMP Double Pole Breaker AC Input 240Vac - 1~ C140 C120 EH-SK110 EH-SK120 P P C125H C125V R P R C110 C125 EH-EK500 C B A C300 EH-RC300 A B C A B C400 EH-EX A B M F 2 PIN WEATHERPACK P R 16 PIN AMP (CPC) WB-EK400 C200 C200 EH-EX EH-FD200 R P 12 PIN DEUTSCH (DT) R P 12 PIN DEUTSCH (DT) C100 C100 EH-EX WB-EK100 R P 8 PIN DEUTSCH (DT) P R C AMP Breaker OPTIONAL WB-EK600 R P 4 PIN DEUTSCH (DT) Radio Receiver (+) (-) DC Input 12Vdc M1 V1 M2 V2 MASTER MASTER CONTROLS COOLER O - OFF O - OFF O - OFF WB-EK300 B A B A EH-EK100 WB-EK200 2

4 Connecting the Reels Red Hose Reel Pressure Red Hose Reel Return Blue Hose Reel Return Blue Hose Reel Pressure 1. Connect the pressure and return hoses. 2. The heat exchanger supply utilizes a check valve. The flow direction can be determined by the arrow stamped on the check valve. Connect this hose to an installer provided #8 SAE 100 R2 hose and connect the other end to the inlet side of the heat exchanger. The inlet side is the port closest to the temperature sending unit. If AMKUS standard couplers are being used, be sure the pressure line has a male coupler at the end of the reel. The return line will have a female coupler at the end of the reel. If AMKUS Mono Couplers are being used, be sure the pressure line is connected to the pressure port (P) of the female Mono Coupler and the return line is connected to the tank port (T) of the female Mono Coupler. Installing the Heat Exchanger (HEA11) Inlet Heat Exchanger Return (Outlet) 3. The heat exchanger return utilizes a check valve. The flow direction can be determined by the arrow stamped on the check valve. Connect this hose to an installer provided #8 SAE 100 R2 hose and connect the other end to the outlet side of the heat exchanger. The outlet side is the port farthest from the temperature sending unit. Installing the Control Panel and VFD Panel (EKDP Control System) Temperature Sending Unit 1. The heat exchanger should be mounted in a location that allows the intake of fresh air. Caution should be taken to prevent recirculation of the heated air. The air intake side of the heat exchanger should have a minimum of 3 inches from any obstruction. The exhaust (fan) side of the heat exchanger should exhaust into free air (no back pressure). 1. The 240SS Control Panel (shown above) houses the green power switch, red and blue motor switches, red and blue reel circuit switches, LED read out, control panel circuit breakers, low oil and temperature high heat indicators. The adjustable mounting brackets (supplied as pictured) can be configured to suit virtually all mounting situations. 3

5 2. Mount the 240SS Control Panel (EKDP Control System) in a compartment using the supplied mounting brackets. The unit should be mounted in a compartment that will be accessible to tool operators. Optional Wireless Receiver Mount the optional wireless receiver using the supplied bolt. The receiver signal range is 300 without an optional antenna. This unit should be installed in a compartment out of the elements. Plug the supply cable into the matching plug from the control panel. Set-Up Procedures 3. Mount the 240SS VFD Panel in a compartment using the supplied mounting brackets. Installing the Optional Wireless Receiver Vent Cap Reservoir Fill Cap Sight Gauge Wireless Remote Controls Receiver The optional Wireless Receiver ships with two remote controls. 1. Remove the black vent cap with a 12mm Hex Key. Unscrew the red reservoir fi ll cap and fi ll the hydraulic fl uid reservoir until the sight gauge is completely full. Replace the black vent cap and the red reservoir fi ll cap. 4

6 Initial Start-Up 1. Connect the hose reel hoses together before starting the system. 5. The upper section of the Control Panel houses the master on power switch (green label), motor 1 switch (blue label), motor 2 switch (red label), valve 1 (blue label activates the blue hydraulic reel), valve 2 (red label activates the red hydraulic reel) and the heat exchanger breaker on/off switch. Turn on the green master switch. 2. Remove the VFD cover. 6. Activate red reel circuit motor. The motor is timecontrolled. Once activated, the indicator will blink for approximately 5 seconds when the motor has reached maximum RPM. 3. The VFD is shipped with the circuit breakers in the OFF position. 7. Activate blue reel circuit motor. The motor is timecontrolled. Once activated, the indicator will blink for approximately 5 seconds when the motor has reached maximum RPM. 4. Place the VFD circuit breakers in the ON position by fl ipping each black switch up. 5

7 Verify Hose Connections Return Line Pressure Line 8. Activate the valve 2 switch to energize the red hydraulic reel. Fluid Flows from Pressure Line 1. To verify which hose is the pressure hose, remove both couplings from the end of the hoses and place the hose ends in a bucket. Charge the appropriate valve. Fluid will fl ow from the pressure line. Turn off the valve once the pressure line is identifi ed. 9. Activate the valve 1 switch to energize the blue hydraulic reel. Sight Gauge Female Coupling Male Coupling 2. If AMKUS standard couplers are being used, place the male coupler on the pressure line and the female coupler on the return line. Repeat for the other reel. 10. Allow the power unit to fl ow through the reels for several minutes while monitoring the fl uid sight gauge level. Shut the power unit off. If AMKUS Mono Couplers are being used, be sure the pressure line is connected to the pressure port (P) of the female Mono Coupler and the return line is connected to the tank port (T) of the female Mono Coupler. 3. Check the sight gauge and add fl uid until the sight gauge is completely full again. 4. Put the black cover back in place and tighten the bolts on both ends. Installation Questions For installation questions, please contact Chuck Sheaffer at or csheaffer@amkus.com 6

8 1 Wireless Remote Control 2 Remote Control Operation 1. Pull Emergency Stop (1) (red) thumb wheel down or counter clockwise to be sure the remote is in the operation mode Move and hold the ON/OFF switch (2) to the Start position. When you release the switch, it will return to the ON position. When held in the Start position the remote is linking up to the receiver mounted in the apparatus so it is best to hold it in the start position briefl y to insure a good signal. 3. Push the Blue (3) and/or Red (4) motor button(s). The motors are programmed to reach full operating range in 5 seconds. 4. Push the Blue (5) and/or Red (6) valve button(s) to activate the red or blue reel circuits. 5. To shut off a circuit, push the appropriate valve (5) and/or (6) button. 6. To quickly shut down the entire system including the power, motors and reel circuits, push the Emergency Stop. To re-activate the system, repeat these instructions starting at number 1. Remote Control Features 1. Emergency Stop (Red) Shuts both circuits and system down. Depress to activate Emergency Stop. Pull thumb wheel down for normal operation. 2. On/Off Start (Black)- ON/OFF turns controller on or off. Start sends signal and links to the truck mounted receiver. 3. Blue Motor Switch Depress to activate motor for blue circuit. Depress again to turn motor off. Note: When motor switch is activated, wait for 5 seconds before activating control valve. 4. Red Motor Switch Depress to activate motor for red circuit. Depress again to turn motor off. Note: When motor switch is activated, wait for 5 seconds before activating control valve. 5. Blue Reel Switch Depress to activate control valve for blue circuit. Depress again to turn control valve off. 6. Red Reel Switch Depress to activate control valve for red circuit. Depress again to turn control valve off. 240SS INSTALL 05/2011 REV. 1 7

9 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting There are four steps necessary to convert the AMK-240SS Power Unit from the Horizontal Mounting Configuration to the Vertical Mounting Configuration as follow: 1. Remove the fill plug and extension from one end of the power unit and swap it with the plastic hex plug at the same end of the power unit. Note: you will need to remove the plastic cap from the solenoid before removing the fill plug and extension. Note: This end of the power unit will become the top end of the unit when it is mounted vertically. Figure 1 Unscrew and remove Plastic Cap from Solenoid Figure 2 Remove Fill Cap and Extension, then swap them with the Plastic Hex Plug Figure 3 After swapping Fill Cap and Hex Plug Page 1 January 24, 2012

10 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting 2. From the opposite end of the power unit, remove the quick coupler assembly from the end cap and swap it with the Plastic Hex Plug. Figure 4 Before swapping Quick Coupler Assembly and Plastic Hex Plug Figure 5 After swapping Quick Coupler Assembly and Plastic Hex Plug Page 2 January 24, 2012

11 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting 2. Remove cap from wiring connector and swap positions with second connector set. Figure 6 Locate the cable that is connected to the sight gage and is terminated with a blank cap. Figure 7 Remove the blank cap. Figure 8 Shown with blank cap removed. Page 3 January 24, 2012

12 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting Figure 9 Locate the adjacent connector with a single green wire. Figure 10 Disconnect the two halves of the connector, Figure 11 Place the blank cap onto the connector half with the green wire. Page 4 January 24, 2012

13 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting Figure 12 Shown with cap installed. Figure 13 Connect the two remaining connector halves together. Each half should have one black wire and one white wire. Figure 14 Shown with the two halves connected. Page 5 January 24, 2012

14 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting 4. Add two vibration mounts and arrange mounting hardware as necessary for your mounting location. Figure 15 Shown as shipped, hanging vertically. Notice four vibration mounts and 2 Z-bracket assemblies. Figure 16 Close-up view of vibration mounts. Figure 17 Lower side vibration mounts removed. Four vibration mounts installed on bottom of unit. Page 6 January 24, 2012

15 Converting AMKUS AMK-240SS Power Unit from Horizontal Mounting to Vertical Mounting Figure 18 Four vibration mounts installed in the bottom of the unit. Figure 19 Note: it is absolutely essential that the two vibration mounts installed on the side near the top of the unit be facing the front of the truck and supported by a wall! Page 7 January 24, 2012

16

17 38 0 [ ] # 1 6 S A E O - R in g ( 2 x ) ( 1 5 / 1 6 " U NF ) 3 60 [ ] 1 73 ± 5 [ ±. 2 0 ] 65 [ 2.56 ] 187 [ ] 1 / 2 " BS PP ( 2 x ) T e m p S w it c h In l e t B l o c k [ 3.94 ] [ 3.94 ] 3 80 [ ] 3 40 [ ] 4 20 [ ] s lo t 9 x 1 2 ( 6x ) s l o t.3 5 x [ ] = = b l i n d fl a n g e ( 2 x ) c o n n e c to r ( 2 x ) [ 2.32 ] [ 5.02 ] each connector can be mounted on two different positions and in three different directions: T h i s d r a w in g a n d a t t a c h e d w r it t e n d i s c lo s u r e, i f a n y, i s o u r in t e ll e c t u a l p r o p e r t y a n d m u s t n o t b e u s e d o r d i s c lo s e d t o t h i r d p a r t ie s w i t h o u t o u r e x p lic i t c o n s e n t. A ll r ig h t s r e s e r v e d. free size tolerance surface m o d if r e v ie w r e le as e w e ig h t H E A /2 4 0S S L. H. JONES EQUIPMENT COMPANY s et up 1:1 item number(s): D i n v d a te s c a le nam e description LH H LH H ML LH H OIL/AIR COOLER 240 AC POWER UNIT 12VDC drawing number page A R E V 1 U S index modification d a te nam e d r a w in g f ile : BC MC MTC u p da te. E R P.: 1 of. pg s.

18 O - OFF O - OFF O - OFF MASTER MOTOR VALVE MOTOR VALVE COOLER #1 #1 #2 # HOT LOW MASTER CONTROLS COOLER OIL OIL

19

Manual: GH2B-MCH Mini Simo Power Unit

Manual: GH2B-MCH Mini Simo Power Unit Understand manual before use. Operating AMKUS Rescue Systems without understanding the manual, receiving proper training, and using appropriate personal protective equipment is a misuse of AMKUS equipment.

More information

Asepsis 21 Delivery Unit

Asepsis 21 Delivery Unit INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.

More information

Hydraulic Immediate Need Power Pack

Hydraulic Immediate Need Power Pack Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read

More information

TABLE OF CONTENTS GEMINI DUAL PUMP KIT

TABLE OF CONTENTS GEMINI DUAL PUMP KIT INSTRUCTION MANUAL TABLE OF CONTENTS GEMINI DUAL PUMP KIT WHAT IS THE GEMINI DUAL PUMP KIT? The kit allows the user to operate two Ace Pumps from one Selective Control Valve (SCV) or the Power Beyond hydraulic

More information

INSTALLATION AND PARTS MANUAL

INSTALLATION AND PARTS MANUAL INSTALLATION AND PARTS MANUAL MODEL H140A FOR CATERPILLAR PS TRACTORS Equipped w/ripper Hydraulics TABLE OF CONTENTS Mounting Group...2 Control Group...4 Dual Solenoid Manifold Valve...10 Hydraulic Motor

More information

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems Page 730.60 Each of the Red and Green Foam Systems consists of one 3000 gallon foam concentrate storage tank, two foam concentrate pumps, a balanced

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D8 D7 D4 D5 D ART_8 J 4 8 D D0 7 R R R R4 TB 80 D D D D4 D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 4 8 INPUT

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information

Rogator 854, 1054 & 1254 Series Installation Manual RG4

Rogator 854, 1054 & 1254 Series Installation Manual RG4 RG4 Rogator 854, 1054 & 1254 Series Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC4.5-BC-RG4-INST Rev D (Rogator 854, 1054 & 1254 Series) NOTICE:

More information

POWER UNIT Operations Manual

POWER UNIT Operations Manual PTO-TWIN-ATT & PTO-TWIN-ATT-LP POWER UNIT Operations Manual PTO-TWIN-ATT PTO-TWIN-ATT-LP TNT Rescue Systems, Inc. 2490 West Oak Street Ashippun, WI 53003 920-474-4101 or 800-474-4189 E-Mail: email@tntrescue.com!

More information

Hydraulic Oil Cooler. Assembly Instructions (Originating w/serial Number )

Hydraulic Oil Cooler. Assembly Instructions (Originating w/serial Number ) Hydraulic Oil Cooler Case 465 Skid Steer Assembly Instructions (Originating w/serial Number 50-101) Model Number: Serial Number: Date of Purchase: Specialized Equipment, Inc. 650 So. Main Street - PO Box

More information

Miller Condor & New Holland Rear Mount Truss Boom Installation Manual MC02

Miller Condor & New Holland Rear Mount Truss Boom Installation Manual MC02 MC02 Miller Condor & New Holland Rear Mount Truss Boom Installation Manual Printed in Canada Copyright 2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-MC02-INST Rev F (Miller Condor & New

More information

Shift Units Installation Instructions

Shift Units Installation Instructions Shift Units Installation Instructions Table of Contents See Page Topic Pneumatic Operation Electric Operation Manual Operation Component Identification 2 2 2 Introduction and Safety Information 3 3 3 Installation

More information

Wireless Remote Transmitter Kit

Wireless Remote Transmitter Kit Wireless Remote Transmitter Kit INSTALLATION INSTRUCTIONS KIT # 8.917-509.0 98004430-1 Part #9.800-443.0 Wireless Kit Rev. 8/13 COMPONENT IDENTIFICATION AND KIT PARTS 14 Receiver Antenna 5 Kit Contents

More information

Adjustment range. Seal material. Pressure connection

Adjustment range. Seal material. Pressure connection 0520 Order matrix for electronic pressure switches.3 Type Adjustment range Pressure connection Seal material lectrical connection Type lectronic pressure switch 0520 Adjustment range 1) for NO 0 145 psi

More information

GH2A-MC Series Mini Power Unit User Information Manual

GH2A-MC Series Mini Power Unit User Information Manual Understand manual before use. Operating AMKUS Rescue Systems without understanding the manual, receiving proper training, and using appropriate personal protective equipment is a misuse of AMKUS equipment.

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

MACHINES RECOVERY. 99 Washington Street Melrose, MA Phone Toll Free SYSTEMS SUPEREVAC

MACHINES RECOVERY. 99 Washington Street Melrose, MA Phone Toll Free SYSTEMS SUPEREVAC 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY SUPEREVAC HOSES 29 RECOVERY HOSES 1/4" 4-IN-1 BALL VALVE TOOL For vacuum,

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D D8 D D D D ART_8 J 8 D D0 R R R R TB 80 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 8 INPUT Steer Left

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D D D D5 D ART_ J D D0 R R R R TB 0 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal INPUT Steer Left 5 OUTPUT

More information

REMOVAL AND INSTALLATION

REMOVAL AND INSTALLATION 303-04C-1 REMOVAL AND INSTALLATION Fuel Injectors Special Tool(s) Caps, Fuel System 310-158 Special Tool(s) 303-04C-1 Holding Rack, Fuel Injector 303-D114 (D94T-9000-E1) Cups, Fuel Injector 303-1261 Tool,

More information

P/N Deluxe Model 1200T WITH THERMOSTAT P/N Standard Model 3550 WITHOUT THERMOSTAT

P/N Deluxe Model 1200T WITH THERMOSTAT P/N Standard Model 3550 WITHOUT THERMOSTAT Read and Save These Instructions From MaxxAir Vent Corporation TURBO/ MaxxAir the leader in RV ventilation 215120 CSA approved. Complies with UL507 TURBO/MAXX 12 Volt Installation Instructions P/N 00-965001

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MiniCOREVentilator ENERGY RECOVERY CORE INSTALLATION INSTRUCTIONS MC500-1ERV JANUARY 10, 2018 SUPERSEDES: NONE INSTALLATION INSTRUCTIONS FOR MINICORE VENTILATOR (MCV) WITH FACTORY INSTALLED OPTIONS USED

More information

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer. Sprayer Control Plumbing & Installation Manual for SprayLink Cable Installations Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Transducer Strainer Relief Regulating Copyrights 2012 TeeJet Technologies.

More information

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches BOLTORQ Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches It is operating manual of BS series and BH series wrenches, please read carefully and follow the instructions. Warning and

More information

# and # FAST Fuel System Kits

# and # FAST Fuel System Kits 1 INSTRUCTIONS #307500 and #307501 Fuel System Kits Thank you for choosing products; we are proud to be your manufacturer of choice. Please read this instruction sheet carefully before beginning the installation.

More information

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

If You Are Experiencing This, Click Thru:

If You Are Experiencing This, Click Thru: HTM04 0 Jericho Turnpike New Hyde Park, NY 040 Tel: () 38-3970 Fax: () 38-7 www.techno-isel.com Techno Stepper DaVinci Trouble Shooting Guide Power Entry Module E-Stop Button 3 Inside 4 Inside 4 3 If You

More information

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

Technical Data Sheet SEVO 1230 Clean Agent Cylinders SEVO 1230 Clean Agent Cylinders 140057, 140069, 140079, 140107, 14817, 14813 U lizing 3M TM Novec TM 1230 Fire Protec on Fluid The agent storage cylinder is a steel pressure vessel manufactured, tested

More information

EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS

EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma Plugs

More information

DIAMOND P R O D U C T S

DIAMOND P R O D U C T S DIAMOND P R O D U C T S Parts List Manual Hydra-Gen 123 HP Power Unit with Electric Controls Part #: CC-HG-SK (January 2008) Part#: 1805052 Table of Contents Hydraulic Pump and Manifold 4 Hydraulic Tank

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

RP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output

RP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output Engineering & Manufacturing Solutions 2.4GHZ Extended Range RP100 Series Radio Receiver Model: RP100 / RP01000002 / 10 Digital Output Sealed To IP67 32-bit Microprocessor ISO 9001:2008 WITH DESIGN Certificate

More information

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS ERA12, 25, 50, 83, 125, 167, IMO-517 (7027) ISSUE 3/97 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS 2 Table of Contents 1 GENERAL...........................................

More information

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications Part Number: 116074 Part Description: Fuel Storage Module (FSM) 123 Gen 2 Back of Cab Product Technical Specifications General Specifications Designed Location... Back Of Cab (BOC) Gasoline Gallon Equivalancy

More information

Copeland Screw TM Compressors

Copeland Screw TM Compressors Copeland Screw TM Compressors Mechanical Guidelines for SHL & SHM Models using ESC-201 Control System Contents: Start-Up Procedure Operating Specifications Maintenance Trouble Shooting Guidelines Start-up

More information

TANK LIDS, REAR STEP AND WHEELS

TANK LIDS, REAR STEP AND WHEELS TANK LIDS, REAR STEP AND WHEELS M9060-22 Rev.4/98 FOR MODELS - KP4F, KP6F, KP6R 4/98 Item Part Number Part Description Qty. 1 9040--16--0 Tank Lid Weldment (KP4F -- Front Load) 1 9060--16--0 Tank Lid Weldment

More information

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) LIFT CORPORATION Sht. 1 of 20 DSG# M-14-32 Rev. B Date: 05/31/2017 INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) FORD SUPER DUTY F-250 PICKUP TRUCKS, 1999-2016 FORD SUPER DUTY

More information

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators Setting the Standard in Mobile Power Instruction Manual for Model HYDRO ARC-S-6500 JSBC Hydraulic Generator Welder Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester,

More information

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch USERS MANUAL TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch N49 W13650 Campbell Drive Menomonee Falls, WI 53051 Phone: 800-88-8178 Fax: 6-783-3510 Website: www.telemotive.com TCK10KMOD-3

More information

KJ4000LW Operating Instructions & Parts Manual NSN

KJ4000LW Operating Instructions & Parts Manual NSN KJ4000LW Operating Instructions & Parts Manual NSN Mandus Group Ltd. KJ4000LW Operators Manual Date: 1 Oct. 2004 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page 2 KJ4000LW

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning

More information

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet 2517 Brass Paddlewheel Flow Sensor * * Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 Rev. F 11/1 English For the most up-to-date information, please refer to our website at www.gfsignet.com SAFETY INSTRUCTIONS 1. Do not

More information

INSTRUCTION, GPTLR POWER DOWN HAND PUMP KIT

INSTRUCTION, GPTLR POWER DOWN HAND PUMP KIT LIFT CORPORATION Sht. 1 of 29 DSG# M-09-18 Rev. ~ Date: 03/05/14 INSTRUCTION, GPTLR POWER DOWN HAND PUMP KIT GPTLR KIT P/N 283332-01 HAND PUMP MOUNT BRACKET P/N 282381-01 QTY. 1 HAND PUMP HANDLE MOUNT

More information

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6. PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER C50201A - 2007½ - 2009 DODGE 6.7L CUMMINS C50202A - 2010-2012 DODGE 6.7L CUMMINS www.powerhalt.com Thank you for your purchase

More information

Tools, Equipment and Supplies Needed:

Tools, Equipment and Supplies Needed: 153-162 DISC BRAKE/DUAL MASTER CYLINDER CONVERSION Please take the time to read the enclosed instructions carefully. If you have any questions, call our Product Assistance personnel for clarifi cation.

More information

IOM Manual. IOM Manual. Series 20/21.

IOM Manual. IOM Manual. Series 20/21. IOM Manual IOM Manual Series 20/21 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

Identify and Assemble the Pneumatic Components

Identify and Assemble the Pneumatic Components Identify and Assemble the Pneumatic Components The 5 Basic Components The Standard GEARS-IDS Pneumatic system is comprised of 5 components. The Reservoir Stores Potential Energy in the form of compressed

More information

Easytork Solenoid Valve IOM

Easytork Solenoid Valve IOM Easytork Solenoid Valve IOM General This installation document is to be read in conjunction with the Easytork Vane Actuator IOM. Description The Easytork Solenoid Valve ( ESV ) series is intended for the

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL SDKIT-730 & SDKIT-734 100% Bolt-On 150 PSI Train Horn System for 2011-2015 F-250 & F-350 Super Duty P/N SDKIT-730 P/N SDKIT-734 Thank you for purchasing a Kleinn Air Horns

More information

GFK-210-C Blower System - Installation and Operating Instructions -

GFK-210-C Blower System - Installation and Operating Instructions - GFK-210-C Blower System - Installation and Operating Instructions - 1.0 INTRODUCTION The GFK-210-C Blower System has been designed to circulate room air through the fi replace to enhance heat output. The

More information

Mounted Instrument Head

Mounted Instrument Head INSTALLATION INSTRUCTIONS for the Asepsis 21 Cabinet TM Mounted Instrument Head SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 4. WATER SUPPLY REQUIREMENTS... 1 5. AIR SUPPLY REQUIREMENTS... 1

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual L-Series Vacuum Pumps Models L/H400C - L/H630C INSTALLATION & OPERATING MANUAL L/H-SERIES SINGLE STAGE ROTARY VANE VACUUM PUMPS L/H400C-L/H630C Please read the manual

More information

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) LIFT CORPORATION Sht. 1 of 22 DSG# M-16-32 Rev. - Date: 12/13/16 INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) FORD SUPER DUTY F-250, F-350 & F-450 PICKUP TRUCKS, 2017 MODEL KIT

More information

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32 Illustrated Parts Guide DSD EDGE 120VAC Illustrated Parts Guide Page 1 of 32 This document is designed to provide a quick reference to the major replacement parts and components for the DSD EDGE. Parts

More information

! WARNING! Read This Manual Before Operating Equipment

! WARNING! Read This Manual Before Operating Equipment ATT-6.5, ATT-6.5-RC, ATT-6.5-LP, ATT-6.5-LP-RC POWER UNIT Operations Manual ATT-6.5 ATT-6.5-RC ATT-6.5-LP ATT-6.5-LP-RC TNT Rescue Systems, Inc. 2490 West Oak Street Ashippun, WI 53003 920-474-4101 or

More information

MARINE ILLUSTRATED PARTS MANUAL MODEL MP6.0L

MARINE ILLUSTRATED PARTS MANUAL MODEL MP6.0L MARINE ILLUSTRATED PARTS MANUAL MODEL MP6.0L L510014 12/02 This Page Was Intentially Left Blank MODEL MP6.0L PARTS MANUAL - 1 Contents: Symbols... 2 Maintenance Item Part Numbers... 3 Cylinder Block Assembly

More information

This sheet must be read completely to:

This sheet must be read completely to: Instalation Preparation This sheet must be read completely to: 2. Avoid causing injury to installer, customer, end user, or others. 3. Prevent damage to ATV, UTV, and Motorcycle and/or accessory. 4. Prevent

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

RAPID-AIR OPERATING INSTRUCTIONS FOR RD317S, RD417M RIM DRIVE

RAPID-AIR OPERATING INSTRUCTIONS FOR RD317S, RD417M RIM DRIVE RAPID-AIR OPERATING INSTRUCTIONS FOR RD37S, RD47M RIM DRIVE RAPID-AIR 460 KISHWAUKEE ST. ROCKFORD, IL. 609-95 PHONE: (85) 397-578 FAX: (85) 398-3887 WEB SITE: www.rapidair.com TABLE OF CONTENTS PAGE. RIM

More information

Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual RG2 & RG6

Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual RG2 & RG6 RG2 & RG6 Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder

More information

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE

More information

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P == B-2000 M-P, PTO, Manual - 2013.002 11/26/13 == SPECIFICATIONS FOR PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P 1 SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE

More information

f i r e - p a r t s. c o m

f i r e - p a r t s. c o m System Overview: The primary components that are included in the SIT Proflame II GTMFS System Gas Valve Integrated Fireplace Control (IFC) SIT Pilot Assembly Transmitter (remote control) (GTMF model) 2

More information

Combo HPU Kidney Loop Motor

Combo HPU Kidney Loop Motor Serial #: See below Product Bulletin # DC-002 Combo HPU Kidney Loop Motor Serial numbers DC1041-DC1050, DC1052, DC1053, DC1055-DC1057, DC1062, DC1064, DC1068, DC1070, DC1072 Background The Combo HPU Part

More information

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump AirLite Sample Pump Cat. No. 110-100 Operating Instructions 863 Valley View Road, Eighty Four, PA 15330 USA Tel: 724-941-9701 e-mail: skctech@skcinc.com www.skcinc.com Pump inlet (inlet fi lter underneath)

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Model 579 Curtain Machine Manual. General Information. Unpacking:

Model 579 Curtain Machine Manual. General Information. Unpacking: Model 579 Curtain Machine Manual. General Information The Model 579 curtain machine is designed for use with most light duty commercial and residential drapery tracks. The 579 curtain machine is designed

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Laser Belt Square Safety and Operation Manual

Laser Belt Square Safety and Operation Manual Laser Belt Square Safety and Operation Manual For squaring conveyor belts for splicing Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous

More information

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual Therm-L-Tec Building Systems LLC Therm-L-Tech Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual Rev. A 10/2014 Index Index 1 Electrical Requirements

More information

CALIFORNIA Proposition 65 Warning:

CALIFORNIA Proposition 65 Warning: PARTS MANUAL P1064 For Models: L1064D, L1064A, M1064D, M1064T1, M1064T2, M1064A, M1064H, NL1064D, NL1064T1, NL1064T2, NL1064H1, NL1064H2, M40C2, M55C2, & M65C2 CALIFORNIA Proposition 65 Warning: Diesel

More information

Geopump Peristaltic Pump Installation and Operation Manual

Geopump Peristaltic Pump Installation and Operation Manual Geopump Peristaltic Pump Installation and Operation Manual Rev. 2 5/24/02 Part # 81350020 TABLE OF CONTENTS Chapter 1: System Description... p. 02 Function and Theory... p. 02 System Components... p. 02

More information

ROADRELAY 5 Installation Guide

ROADRELAY 5 Installation Guide ROADRELAY 5 Installation Guide ROADRELAY 5 Installation Guide Bulletin No. 4971214 Revision A Copyright 2011, Cummins Inc. All rights reserved. Cummins Inc. shall not be liable for technical or editorial

More information

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by: DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL Manufactured by PSDS, Inc. for sole distribution by: AEROSTAT, INC. 8830 AIRPORT BLVD LEESBURG, FL 34788 WEBSITE: AEROSTATINC.COM TEL: 352 787-1348

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its constituents

More information

THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS

THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS PAGE 1 OF 13 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma

More information

P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its

More information

ILD PLUS 33, 44, 55, 66

ILD PLUS 33, 44, 55, 66 ILD PLUS 33,,, PARTS MANUAL ECN-M0XXX Rev. 1., Date 0--201 Part #0-1-000 13 Piuma Ave., Cerritos, CA 0703 Tel ()-77- Fax (2)--31 72 Whitehead Road, Trenton, NJ 01 Tel (0)-7-200 Fax (0)-7-201 Visit our

More information

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers DAH Left Hand Hose Inlet Kit 98-54-1 Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers BASIC KIT FUNCTION: The left hand hose inlet kit has two main functions. The kit can be

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TECHNICAL INSTRUCTIONS 24 Month Maintenance Kit Instructions For Benchmark 2500-3000 Boilers Maintenance Kit # 58025-10 Flame Detector P/N 66034 Ignitor- Injector P/N 58023 Exhaust Manifold Seal P/N 84040

More information

RCL-600A PRODUCT SUPPORT MANUAL. Y Rev. B. Remote Control Searchlight with Joystick Remote Control Panel. Product No.

RCL-600A PRODUCT SUPPORT MANUAL. Y Rev. B. Remote Control Searchlight with Joystick Remote Control Panel. Product No. PRODUCT SUPPORT MANUAL Y1-03-0139 Rev. B RCL-600A Product No. 1941 & 1943 Remote Control Searchlight with Joystick Remote Control Panel ACR Electronics, Inc. 5757 Ravenswood Road Fort Lauderdale, Fl 33312

More information

INSTRUCTIONS, NISSAN TITAN TRUCK INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTIONS, NISSAN TITAN TRUCK INSTALLATION KIT (C2 PICKUP LIFTGATES) LIFT CORPORATION Sht. 1 of 18 DSG# M-14-33 Rev. A Date: 05/31/2017 INSTRUCTIONS, NISSAN TITAN TRUCK INSTALLATION KIT (C2 PICKUP LIFTGATES) NISSAN TITAN PICKUP TRUCKS, 2004-2015 KIT P/N 295040-01 MOUNTING

More information

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO... Electrically Operated Pressure Relief Cartridge, Size Seated Design, Direct Acting Series WUVA LO....5 l/min, 40 bar Wet armature solenoid with high pressure core tube and slip on coil Coils can be changed

More information

SERVICE PARTS LIST for

SERVICE PARTS LIST for T-295PL Manual SERVICE PARTS LIST for MODEL GR-60 (N.A.O.) Rooftop Air Conditioning Unit T-295PL REV. 06/202 202 Mobile Climate Control TABLE OF CONTENTS PARAGRAPH NUMBER Page INTRODUCTION... i MODEL CHART...

More information

VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS

VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS VC-NR-100 SERIES STAINLESS STEEL, VERTICAL CANISTER PNEUMATIC ACTUATOR & SSBT SERIES CONTROL TOPS BRADFORD VC-NR-100 SERIES ACTUATOR & CONTROL TOP FEATURES SPECIFICATIONS & DIMENSIONS FEATURES Excellent

More information

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HY-TRANS THE PRODUCTION LINE OF HANSA-TMP Via M.L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

Magnetic Drive Gear Pump

Magnetic Drive Gear Pump Magnetic Drive Gear Pump Installation / Operation Manual DF-A8-T DFS-A8-T DT-A7-T DT-A6-T Model Numbers Covered: DT-A8-T DTP-A7-T DTP-A6-T DTP-A8-T DTPS-A8-T DTS-A7-T DTS-A6-T DTS-A8-T SST-A7-T SST-A90-T

More information

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RA 183-52/1.11 1/1 4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections B8_8 (EDBZ) Summary Description Page General specifications 1 Ordering

More information

THAWZALL Manufactured by THAWZALL, Inc. MODEL 2M SPECIFICATIONS AND PERFORMANCE SPECIFICATIONS: MODEL 2M

THAWZALL Manufactured by THAWZALL, Inc. MODEL 2M SPECIFICATIONS AND PERFORMANCE SPECIFICATIONS: MODEL 2M THAWZALL Manufactured by THAWZALL, Inc. MODEL 2M SPECIFICATIONS AND PERFORMANCE SPECIFICATIONS: MODEL 2M Height 78 Inches Width 74 Inches Length 144 Inches Weight (Including Fuel) 3,006 Lbs. Fuel Capacity

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 DEVICES COVERED IN THESE INSTRUCTIONS: RX Request to Exit ELECTRICAL SPECIFICATIONS Note: SPDT mechanical

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com

More information