ZONE DAMPERS. Form No. PDS DAMP.0.3
|
|
- Jemima McLaughlin
- 5 years ago
- Views:
Transcription
1 90 ZONE DMPERS IRFLOW IRFLOW CLS COM OPN ROUND DMPER FETURES/ENEFITS ryant zone dampers are the latest in design and were developed to fit field requirements for a variety of duct work shapes and sizes. These dampers use 24-vac direct-drive actuators for smooth, quiet performance. There is a 1/2-in. direct-drive mounting hub for securing the damper blade and shaft to the actuator housing. position indicator and angular rotation stop for viewing or manually setting minimum-maximum damper positions facilitate ease of installation. spring loaded disengagement button to momentarily release main gear and damper blade allows for manual positioning of installed dampers. The damper motor and terminal block wiring are protected by a plastic cover with a removable door. Permanently lubricated bushings, with a split shaft design for round and rectangular style dampers, secure the damper blade to the shaft for efficient reliable service CLS COM OPN RECTNGULR DMPER SLIP-IN DMPER Form No. PDS DMP.0.3
2 MODEL NUMER NOMENCLTURE DMP SLS 08x10 Damper Length x Width, Diameter INC for Round Slip-In Side Mount (SLS) Slip-In ottom Mount (SL) Round (RND) Rectangular (REC) arometric (R) 2
3 SLIP-IN DMPERS SIDE MOUNT IR DUCT NGULR ROTTION STOPS SIDE RIL 1 LISTED DMPER HEIGHT CLS OPN QUICK LDE RELESE UTTON (RED) SIDE RIL OTTOM MOUNT SIDE RIL SIDE RIL IR DUCT NGULR ROTTION STOPS CLS OPN LISTED DMPER WIDTH 1 QUICK LDE RELESE UTTON (RED) NOTE: See dimensions on next page
4 SLIP-IN DMPER DIMENSIONS (In.) PRT NO. POSITION DMPSLS08x10 side mount 9-7/8 7-13/16 DMPSL08x10 bottom mount 7-13/16 9-7/8 DMPSLS08x12 side mount 11-7/8 7-13/16 DMPSL08x12 bottom mount 7-13/ /8 DMPSLS08x14 side mount 13-7/8 7-13/16 DMPSL08x14 bottom mount 7-13/ /8 DMPSLS08x16 side mount 15-7/8 7-3/16 DMPSL08x16 bottom mount 7-13/ /8 DMPSLS08x18 side mount 17-7/8 7-13/16 DMPSL08x18 bottom mount 7-13/ /8 DMPSL08x20 bottom mount 7-13/ /8 DMPSL08x22 bottom mount 7-13/ /8 DMPSL08x24 bottom mount 7-13/ /8 DMPSLS10x10 side mount 9-7/8 9-13/16 DMPSL10x10 bottom mount 9-13/16 9-7/8 DMPSLS10x12 side mount 11-7/8 9-13/16 DMPSL10x12 bottom mount 9-13/ /8 DMPSLS10x14 side mount 13-7/8 9-13/16 DMPSL10x14 bottom mount 9-13/ /8 DMPSLS10x16 side mount 15-7/8 9-13/16 DMPSL10x16 bottom mount 9-13/ /8 DMPSLS10x18 side mount 17-7/8 9-13/16 DMPSL10x18 bottom mount 9-13/ /8 DMPSL10x20 bottom mount 9-13/ /8 DMPSL10x22 bottom mount 9-13/ /8 DMPSL10x24 bottom mount 9-13/ /8 DMPSL14x20 bottom mount 13-13/ /8 ROUND DMPERS C ROUND DMPER DIMENSIONS (In.) PRT NO. C DMPRND06INC /2 DMPRND08INC /2 DMPRND10INC /2 DMPRND12INC /2 DMPRND14INC /2 DMPRND16INC /2 4
5 RECTNGULR DMPERS C D E PLCES RECTNGULR DMPER DIMENSIONS (In.) PRT NO. C D E DMPREC08x /4 13-1/2 12-1/4 DMPREC08x /4 13-1/2 12-1/4 DMPREC08x /4 13-1/2 12-1/4 DMPREC08x /4 13-1/2 12-1/4 DMPREC10x /4 15-1/2 14-1/4 DMPREC10x /4 15-1/2 14-1/4 DMPREC10x /4 15-1/2 14-1/4 DMPREC10x /4 15-1/2 14-1/4 RECTNGULR ROMETRIC YPSS DMPERS D C PLCES DMPER DIMENSIONS (In.) PRT NO. C D MX IRFLOW DMPR08x /4 13-1/ CFM DMPR08x / CFM 5
6 ROUND DMPERS D SHFT E LDE WEIGHT RM C WEIGHT ROUND ROMETRIC YPSS DMPER DIMENSIONS (In.) PRT NO. C D E NUMER OF WEIGHTS MX IRFLOW DMPR08INC /16 1-1/ DMPR10INC / /16 1-1/ DMPR12INC / / DMPR14INC / /16 1-1/ MPR16INC / /16 1-1/ PHYSICL DT Input Voltage 24 vac Nominal Input Power 2 va Damper Output Torque in. - Lb mbient Temperatures 0 F to 140 F or 18 C to 60 C Wire Connections Common, Open, Close Wire Connectors Plated Screw Terminals For WG Stroke Time ngular Rotation per Sec DMPCT45DEG 3 per Sec DMPCT90DEG 6 per Sec Travel Time 15 Sec arometric ypass Pressure Range in. wc 6
7 DMPER DMPER PRESSURE DROP IRFLOW DT 400 FPM 600 FPM 800 FPM In. In. In. NOTE: s the design airflow for dampers is exceeded, the potential for airflow noise problems increases. HOW TO USE PRESSURE DROP DT 1. Calculate airflow for each zone based on load and number of zones. 2. s duct system is designed, calculate pressure losses in each duct run and in the air handler (filter and cooling coil). 3. ased on the duct size and amount of airflow required in each zone, calculate a duct velocity for the air through the damper. 4. Use the chart to find the pressure drop for the damper and the calculated velocity in each duct run. 5. Put the damper pressure drop data into the duct losses for each run and calculate a total system pressure loss. 6. Make sure that the unit specified for the application will supply the required amount of air for the calculated system pressure loss. 7. Make sure that the maximum airflow for each damper is not exceeded. Example: ssume an installation requires a maximum airflow of 600 CFM per zone. DESIGN LIMIT (CFM) If 8-in. x 18-in. ducts are used in the house the duct area is 8-in. x 18-in. /(144 sq in. per sq ft) gives 1.0 sq ft of duct area. Dividing the airflow for each zone (600 CFM) by the duct area (1.0 sq ft) gives 600 fpm. DMPREC08X18: 0.03-in. DMPSLS08X18: 0.05-in. DMPSL08X18: 0.05-in. ottom mount slip-in dampers were chosen for this installation. Therefore 0.05-in. of pressure drop should be added to each duct run. MXIMUM (CFM) DMPSL08X DMPSLS08X DMPSL08X DMPSLS08X DMPSL08X DMPSLS08X DMPSL08X DMPSLS08X DMPSL08X DMPSLS08X DMPSL08X DMPSL08X DMPSL08X DMPSL10X DMPSLS10X DMPSL10X DMPSLS10X DMPSL10X DMPSLS10X DMPSL10X DMPSLS10X DMPSL10X DMPSLS10X DMPSL10X DMPSL10X DMPSL10X DMPSL14X DMPRND06INC DMPRND08INC DMPRND10INC DMPRND12INC DMPRND14INC DMPRND16INC DMPREC08X DMPREC08X DMPREC08X DMPREC08X DMPREC10X DMPREC10X DMPREC10X DMPREC10X
8 SPECIFICTIONS SUJECT TO CHNGE WITHOUT NOTICE UNIT MUST E INSTLLED IN CCORDNCE WITH INSTLLTION INSTRUCTIONS Cancels: PDS DMP ryant Heating & Cooling Systems 7310 W. Morris Indianapolis, IN PRINTED IN U.S.. Catalog No. 12D-MP1 9-98
Product Data. Residential Zone Dampers FEATURES/BENEFITS
Product Data Residential Zone Dampers FETURES/ENEFITS IRFLOW CLS COM OPN IRFLOW 90 0 45 ROUND DMPER CLS COM OPN 90 0 45 RECTNGULR DMPER Carrier residential zone dampers are the latest in design and were
More informationProduct Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper
CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW Fig. 3 - Slip -In Damper 05253 Fig. 1 - Round Damper 05251 FETURES/ENEFITS CLS COM OPN Carrier zone dampers are the latest in design and were
More informationProduct Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper
CLS COM OPN CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW 05253 Fig.3 Slip-InDamper Fig.1 RoundDamper 05251 FETURES/ENEFITS Carrier zone dampers are the latest in design and were developed
More informationFSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationAir Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation
ir Flow Factors Model: TDC irflow Measurements Procedure 1. Record diffuser velocities with lnor probe in the locations and orientation shown the velocity Measurement Location Chart. Note: Each diagram
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationCCS Zone/Bypass Damper Assembly
Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control
More informationFSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series
More informationProduct Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System
Product Data ZONEKIT4ZCAR Comfort Zone Residential Zoning System Comfort Zone is a residential 4-zone system integrated for home comfort. The Comfort Zone kit includes the Comfort Zone Center, 4-zone controller,
More informationB1-2. Table of Contents LOUVERED FACE DIFFUSERS
Table of Contents 2, FR,, M & M feature a round neck and four cones. & feature a round neck, four cones, and adjustable pattern controllers.,, M, & M feature a round neck and three cones. & feature a round
More informationMODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS
LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models
More informationFIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION
FIERGLSS ROUND CONTROL S INTRODUCTION The M.K. Plastics series K-RD are manufactured to meet the needs of the odor control and corrosive HVC industries by providing a corrosion-resistant FRP Damper that
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationGMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC
On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers
More informationDRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION
DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers
More informationGeneral TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.
General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationCLASS 4FANS BACKWARDLY INCLINED CENTRIFUGAL. Visit us on the Web: Phone: (800)
CKWRDLY INCLINED CENTRIFUGL CLSS 4FNS ULLETIN 161 JNURY, 2014 Capacities to 170,000 Static pressures to 20 WG Temperatures to 750 F. CLSS I, II, III FNS also available THE NEW YORK LOWER COMPNY 7660 Quincy
More informationRPD ROUND PLAQUE DIFFUSER
ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.
More informationLOUVERED FACE GRILLES AND REGISTERS
Performance Notes for Supply rilles and Registers, 6 and 67 Series Throw, Spread and Drop The isovel diagrams shown below, illustrate in plan view, the relationship of horizontal spread to throw for three
More informationProduct Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL
SYSTXCCUIZ01-- V Infinityt Zone Control Product Data A07258 NOTE: Infinityt Zone Control compatible with Infinity rated indoor equipment only. INFINITY t ZONE CONTROL Carrierr specializes in creating a
More informationVAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE
TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil
More information500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)
500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationYCCS Zone/Bypass Damper Assembly
YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper Assemblies are zone control and pressure control devices that
More informationMISCELLANEOUS INDEX PAGE DATE SERIES DESCRIPTION
MISCELLNEOUS INDEX 08/01/11 PGE DTE SERIES DESCRIPTION M-1 08/01/11 Miscellaneous Index M-2 04/16/96 M01 Tooling all M-3 04/16/96 M02 Scrap Chute Hook and Retainer racket M-4 01/03/95 M03 Scrap Chute Chain
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationINLET BOXES AND INLET-BOX DAMPERS
INLET BOXES AND INLET-BOX DAMPERS Available on these Arrangement 1, 4, 8, 9, 9F, and 10 fans: GENERAL PURPOSE FANS ACOUSTAFOIL/PLR FANS CLASS IV FANS AF FANS RTS FANS GI FANS HPBC FANS BC FANS BCPB FANS
More informationFOR USE IN SOLUTION AIR HANDLING UNITS
AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines
More informationMODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING
DIRECT DRIVE SIDEWLL PROPELLER FNS WLL HOUSING MOUNTING OPTIONS WLL HOUSING: This heavy-gauge, all galvanized G-90 steel (aluminum optional) housing provides a simple solution to installing a fan and all
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationInstallation and Start-Up Instructions
Visit www.carrier.com SYSTXCC4ZC01 Infinity Control Installation and Start-Up Instructions Infinity Control SYSTXCC4ZC01 A97040 NOTE: Read the entire instruction manual before starting the installation.
More informationINTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter
INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free
More informationFIBERGLASS DAMPERS FOR ODOR CONTROL AND CORROSIVE HVAC SYSTEMS
FIERGLSS S FOR ODOR CONTROL ND CORROSIVE HVC SYSTEMS ELCO FIERGLSS S ELCO Fiberglass Dampers are manufactured to meet the needs of the odor control and corrosive HVC industries by providing a corrosion-resistant
More informationCONTROL DAMPERS. Models 1810 & Model Model Model 1370
CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and
More informationOE326-23I-OR VAV/Zone Controller
+ 4 8 - Description The OE36-3I-OR is a that is designed for pressure independent VAV Box and Zone Damper applications. It is supplied with an integral Airflow Sensor and is mounted in a plastic enclosure.
More informationThe Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP
The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed
More informationMODEL GED SIDEWALL DIRECT DRIVE PROPELLER FAN
PROPELLER WLL FNS DIMENSIONL DT GED SIDEWLL DIRECT DRIVE PROPELLER FN PPLICTION Soler & Palau type GED wall propeller fans feature the maximum efficiency, low maintenance and durable, economical operation
More informationProduct Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)
Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic
More informationMOUNTING ARRANGEMENT OPTIONS OVERVIEW
ELT DRIVE SIDEWLL PROPELLER FNS MOUNTING RRNGEMENT OPTIONS OVERVIEW Page Mounting rrangement Description 2-3 Housing Heavy-gauge, all galvanized G-90 steel housing provides a simple solution to installing
More informationD2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS
D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable
More informationTotally Enclosed, Ball Bearing Motor High Efficiency 2 Speed, Single Phase; or, Single Speed, Three Phase Motors Available
Direct Drive Fans Low Pressure Industrial Duty MODEL PD 1 Year Warranty Totally Enclosed, Ball Bearing Motor High Efficiency 2 Speed, Single Phase; or, Single Speed, Three Phase Motors Available Totally
More informationIntroduction to Johnson Controls Dampers
Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader
More informationSolutions from SPTT-3
Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static
More informationFE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT
Technical Data Sheet FE-1000 INSERTION TYPE IR SENSING ELEMENT DESCRIPTION The FE-1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing
More informationProduct Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL
SYSTXBBUIZ01 -D Evolutiont Zone Control Product Data A10287 NOTE: Evolutiont Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryantr specializes in creating
More informationRD-2000 Round Control Dampers
RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,
More informationGRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS
GRD PRODUCT CATALOG PRODUCTS 2018 Metal Industries, Inc. PRODUCTS Displacement Ventilation systems provide conditioned air at floor level at very low velocity and allow heat sources within the room (like
More informationPC-125x Counter-Balanced Backdraft Damper
PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls
More informationAD-1251 Probe with Differential Pressure Transducer
AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)
More informationInstallation and Start Up Instructions
SYSTXCC4ZC01 Infinityr Control Installation and Start Up Instructions A97040 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,
More informationSINGLE DUCT TERMINAL UNITS 3000 SERIES
000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume
More informationINLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK
INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationRegisters for spiral ducts
Registers for spiral ducts RGS-3 5 The RGS-3 is a supply/return register with adjustable double deflection blades and a volume damper designed specifically for direct mounting on a spiral duct. The use
More informationATP-2040 Electric Damper Actuator/Transmitter
ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential
More informationBULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven
BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the
More informationGRAVITY VENTILATORS SIZING
GRAVITY VENTILATORS SIZING BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to field conditions and size choices. The following
More informationSquare/Rect. and Square Louvered Face and Plaque Face Diffuser
/Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are
More informationCONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7
CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy
More informationLINEAR DIFFUSERS AND BAR GRILLES
49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice
More informationYCCS Zone/Bypass Damper Assembly
YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper are zone control and pressure control devices that include
More informationLMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma
LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationModel DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated
More informationNMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply
More informationQuiet-Duct Conic-Flow Silencers Section Specifications
Quiet-Duct Conic-Flow Silencers Section 15000 Specifications 1.01 General A. Furnish and install Conic-Flow (tubular) silencers of the types and sizes shown on the plans and/or listed in the schedule.
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationMIN/MAX PERFORMANCE IN INCHES WG
Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels
More informationEGG CRATE RETURN GRILLE
80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders
More informationTED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially
More informationVOLUME CONTROL DAMPERS
VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome
More informationCAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS
CAT PAU 99(2) SUPERSEDES CAT.NO.200-95 SARAVEL PACKAGED AIR CONDITIONING UNITS TABLE OF CONTENTS Introduction...3 Physical Data..... 4 Selection Procedure....5-7 Water Cooled Packaged Unit Ratings....
More informationMODELS LCE/LCS, L2E/L2S, L3E/L3S
ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,
More information6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR
C Table of Contents 6, 6 6, 6 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 62, 62 62FR, 629F supply,
More informationAir Quality Solutions
Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE
More informationLeakage rate. Valve body. U.S. Registered Trademark EN0B-0308GE51 R1002 Copyright 2002 Honeywell Inc. All rights reserved
V5832/58,C SMLL LINER VLVES PN16 FOR MODULTING ND ON/OFFCONTROL V5832 V58 SPECIFICTION DT FETURES Small size allows installation where space is limited Long stroke results in a high quality characteristic
More informationModel DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated
More informationControl Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers
Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame
More informationNMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should
More informationCeiling and Inline Fans
Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4
More informationMOTORIZED VOLUME DAMPER
MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers
More informationD1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...
D Table of Contents, These supply, ceiling diffusers feature four handremovable modular cores. Available in steel or aluminum construction. P, P These supply, ceiling diffusers feature four handremovable
More informationFSD60/MFSD60 Multi-blade Fire Damper
DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today
More informationLMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers
More informationConcentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.
Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination
More informationConnection and regulation kit for HVAC terminal units
Connection and regulation kit for HVC terminal units 149 series 01336/18 G FM 21654 003 Function The preassembled group for terminal units is compact and able to shutoff, adjust and filter the secondary
More informationMC-351, 421, 431, MC-4311
MC-35, 42, 43, MC-43 Three-Wire, Two Position Actuators General Instructions Applications For two-position operation of dampers or valves in heating, ventilating and air-conditioning systems and similar
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationModel DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL 555 classifies dynamic rated fire
More informationVANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG
BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG
More informationV5832A/5833A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS
V5832/5833,C SMLL LINER VLVES PN16 FOR MODULTING ND ON/OFFCONTROL V5832 V5833 SPECIFICTION DT FETURES Small size allows installation where space is limited Long stroke results in a high quality characteristic
More informationNomenclature. Contents. Air Handling Unit SR AH 250 LP HS
SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal
More information