OE326-23I-OR VAV/Zone Controller

Size: px
Start display at page:

Download "OE326-23I-OR VAV/Zone Controller"

Transcription

1 Description The OE36-3I-OR is a that is designed for pressure independent VAV Box and Zone Damper applications. It is supplied with an integral Airflow Sensor and is mounted in a plastic enclosure. The is designed for use with an OE8-0 Damper Actuator with cable package. The controller and actuator can be purchased separately or as a combined package (referenced below). The connects to the actuator via the modular cable included with the actuator. One stage of Aux Heat is provided on the controller. The can use a Standard Room Temperature Sensor wired to the 3 pole terminal block provided or an E-BUS Digital Room Sensor connected via the integral E-BUS cable connector or to the 4 pole terminal block provided. The also has a pole terminal block for wiring a Discharge Temperature Sensor, if desired. An optional Reheat Expansion Module is available for applications using fan terminals and/or more than stage of Heat, SCR electric heat, or if using modulating HW heat. The Expansion Module connects to the by means of a prefabricated E-BUS cable. Package OE744-0P-VAVZ (Pressure Independent Package) includes the Zone and Actuator. Package OE744-03P- VAVZ (Pressure Independent Package) includes the Zone, Actuator, and Reheat Expansion Module OE36-3I-OR Mounting The is very easy to mount on your terminal unit or to a round or rectangular damper mounting plate. Three holes are provided in the plastic controller housing for mounting to a control panel base. Detailed mounting and installation instructions are provided with each package. Form: ORION-OE36-3I-OR-0A.doc Page of OCC. SWITCH BIN C9.00uF E-BUS TB4 DUCT SENSOR C34 R60 R59 COMM POWER INPUT P TMP R+ SH T- 0uF 48 - C5 R4 R3 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED WattMaster Label #L037 Rev.: 0A B D7 R TB DIGITAL SPACE C US.05 D9 E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT J ON ADDRESS +V R5 R30 R9 R8 OCCUPIED SWITCH BIN DUCT TEMP SENSOR R5 R5 OFF R TB6 TMP ADDRESS ON 6 3 R37 SPACE SENSOR 5.05 DIGITAL SPACE SENSOR LOOP BAUD SW ADJ TMP R37 C5 R0 R C4 R6 + V AUX HEAT 6 3 VDE VDC VAC ~ D3 + VDC TB3 HI LO HI ANALOG SPACE SENSOR OE36-3I-OR P.I. VAV /ZONE CONTROLLER Technical Data OE36-3I-OR Pressure Independent General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption Operating Temperature Operating Humidity ADDRESS SWITCH BAUD 475 AUXILIARY HEAT 475 0uF RELAY CONTACT RATING IS AMP 4 VAC V4 TB5 D R4 D R CCW C5 CW 0 ACTUATOR ADJ TMP COM HEAT P3 LO 3.3V 5.0V AIRFLOW TP YS0588 REV 6 VA Maximum () Pole Terminal Block Connector For Power In 0 F to 49 F 0-90% RH Non-Condensing ACTUATOR CONNECTOR V3 SERIAL # () Pole Terminal Block For Discharge Temperature Sensor Connection () Pole Terminal Block for Occupancy or Window Switch Terminals Communications RS ,600 Baud Hi & Lo Pressure Tube Fittings For Integral Air Flow Sensor (P.I. s Only) Inputs: Outputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Sensor Applications () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty

2 B R C US Description The OE36-3D-OR is a designed for pressure dependent VAV Box and Zone Damper applications and is mounted in a plastic enclosure. The is designed for use with an OE8-0 Damper Actuator with cable package. The controller and actuator can be purchased separately or as a combined package (referenced below). The connects to the actuator via the modular cable that is included with the actuator. One stage of Aux Heat is provided on the controller. The can use a Standard Room Temperature Sensor wired to the 3 pole terminal block provided or an E-BUS Digital Room Sensor connected via the integral E-BUS cable connector or to the 4 pole terminal block provided. The also has a pole terminal block for wiring a Discharge Temperature Sensor, if desired. An optional Reheat Expansion Module is available for applications using fan terminals and/or more than stage of Heat, SCR electric heat, or if using modulating HW heat. The Expansion Module connects to the by means of a prefabricated E-BUS cable. Package OE74-0P-VAVZ (Pressure Dependent Package) includes the Zone and Actuator. Package OE74-03P-VAVZ (Pressure Dependent Package) includes the Zone, Actuator, and Reheat Expansion Module OCC. SWITCH OE36-3D-OR P.D Mounting The is very easy to mount on your terminal unit or to a round or rectangular damper mounting plate. Three holes are provided in the plastic controller housing for mounting to a control panel base. Detailed mounting and installation instructions are provided with each package. BIN C9.00uF 48 E-BUS TB4 DUCT SENSOR - C34 R60 R59 COMM POWER INPUT WattMaster Label #L038 Rev.: 0A P TMP D7 0uF R+ SH T- C5 R4 R3 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED TB DIGITAL SPACE D9 E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT J ON ADDRESS +V R5 R30 R9 R8 OCCUPIED SWITCH BIN DUCT TEMP SENSOR R5 R5 OFF R TB6 6 3 R37 SPACE SENSOR TMP ADDRESS ON 5.05 LOOP BAUD SW ADJ TMP R37 C5 R0 R C4 R6 DIGITAL SPACE SENSOR V + AUX HEAT VDE VDC VAC ~ D3 + VDC TB3 475 ANALOG SPACE SENSOR OE36-3D-OR P.D. VAV /ZONE CONTROLLER ADDRESS SWITCH 6 3 BAUD 475 0uF V4 RELAY CONTACT RATING IS AMP 4 VAC AUXILIARY HEAT TB5 D R4 D R CCW C5 CW 0 ACTUATOR ADJ TMP COM P3 HEAT ACTUATOR CONNECTOR 3.3V 5.0V AIRFLOW TP YS0588 REV V3 SERIAL # Technical Data OE36-3D-OR P.D. General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption 6 VA Maximum () Pole Terminal Block Connector For Power In Operating Temperature 0 F to 49 F () Pole Terminal Block For Discharge Temperature Sensor Connection Operating Humidity Communications Inputs: 0-90% RH Non-Condensing RS ,600 Baud () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Temperature Sensor Applications () Pole Terminal Block for Occupancy or Window Switch Terminals Outputs: () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: ORION-OE36-3D-OR -0A.doc Page of

3 5.70 OE8-0 Zone Damper Actuator Description The OE8-0 Zone Damper Actuator is a shaft mounted, floating point control actuator with an included phone jack cable. Actuators are 4VAC/4VDC with a 0K ohm feedback signal for position monitoring. Wiring connection to the actuator is by means of a modular phone cable connector located on the actuator cover. The actuator is rated for 45 in-lb of torque. All actuators are electronically protected against overload. The angle of rotation is mechanically limited to 95. When the end position of the actuator or damper is reached, the actuator automatically stops. For adjustment purposes, the gears can be manually disengaged by pushing the manual override button on the actuator cover OE8 Damper Actuator Applications The OE8-0 Zone Damper Actuator is used to provide control of air volume dampers in a VAV or Zoning system. Modular Jack Connection 0.75 The actuator is included in the OE74-0P-VAVZ or OE74-03P-VAVZ. P.D. Packages or the OE744-0P-VAVZ and OE744-03P-VAVZ. P.I. Packages. 8 Long Modular Cable The OE8-0 Zone Damper Actuator is also included in the following zone damper packages: OE50-XX-PT, OE50-XX-PM, OE5-XX-PT, and OE5-XX-PM, where XX = 06,08,,4,6 the size of the damper. Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA Certified and/or culus acc. to UL A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. Three Year Warranty WattMaster reserves the right to change specifications without notice Form: ORION-OE8-0ZoneDmprAct-Sub-0B.doc Page of

4 OE35-03 Expansion Module Description The OE35-03 Expansion Module is used in conjunction with the OE36-3I-OR & OE36-3D-OR to allow for control of fans included in series and parallel flow fan terminal units and/or additional staged or modulating heat. It can also control up to 3 stages of electric heat, SCR electric heat, on/off HW heat, or modulating hot water heat. The OE35-03 Expansion Module provides 4 relay outputs for pilot duty switching control, ( fan and 3 heat) relay outputs and analog output for control of a 0-0V modulating hot water valve or SCR controlled electric heating coil. SERIAL # P U6 TB D4 R8 C9 R7 R6 AOUT U5 R3 R R R0 C 05 YS053 REV R WATTMASTER CONTROLS, INC D MADE IN USA Q C0 R9 C C7 C6 U7 R U3 3.0" US C8 TB R R C U8 D Q U4 R D5 R3 C R8 J U R0 R9 D3 BIN R D6 D3 Q3 R3 D7 D8 COM D4 Q4 U C3 C X C3 ALRM STAT COMM PWR TB3 R5 C4 C5 R5 R6 R7 R4 4.8" 4.34".35" The OE35-03 Expansion Module connects to the controllers mentioned previously by means of an E-BUS cable that is provided with the Expansion Module. Power to this board is also supplied to the board by means of this E-BUS cable for the. De-pluggable screw terminals are provided for connection of field wiring to the relays outputs, the analog outputs, and the binary input (not used in this application). The relay outputs are N.O. contacts with one common terminal. All outputs and the relay common are electrically isolated from all other circuitry on the board. All relay outputs are supplied with transient suppression devices across each set of contacts to reduce EMI and contact arcing. The relay output circuits are rated for pilot duty control of a maximum of 4 VAC or 4 VDC each. These outputs require a separate 4 VAC transformer provided by others. The analog output provides a 0-0 VDC modulating signal output into a K Ohm minimum load. If a Modulating Hot Water Valve is being used, it will also need a 4 VAC transformer by others for its power source. Mounting The OE35-03 Expansion Module is supplied mounted on a plastic snap track channel. The snap track channel has a single mounting hole which is used to field mount the board with the provided screw. The module should be mounted in close proximity to the to allow for connection with the supplied E-BUS cable. Technical Data OE35-03 Expansion Module Operating Temp 0 F to 49 F Operating Humidity 0-90% RH Non-Condensing Weight 4 oz. Connection to : E-BUS Modular Cable Analog Output Qty & Rating Relay Output Qty. Relay Circuit Rating Outputs: () 0-0 K Ohm Minimum load 4 Electrically Isolated 4 VAC Binary Input E-BUS CABLE PL053 EXPANSION BOARD 8.00" Inputs: SNAP TRACK CHANNEL Not Used for this Application Form: ORION-OE35-03-ExpMod-0A.doc Page of

5 OE74-03-OR Pressure Dependent Package Description The OE74-03-OR Pressure Dependent Package with Terminal Block connectors provides the latest solution for zone damper applications. The package includes the OE36-3D-OR mounted in a plastic enclosure and the OE8-0 Zone Damper Actuator with cable. Mounting The Package is very easy to mount on your terminal unit. There are four conduit holes that are sized for ½ conduit fittings that are provided for as part of the mounting plate that is on the Orion series of zone dampers - OE50-XX-PT or OE5-XX-PT. The rectangular damper kit also has four ½ conduit knock-outs in its enclosure as well. Detailed mounting and installation instructions are provided with each VAV Zone Package. Technical Data OE36-3D-OR P.D. Zone General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Power Consumption 6 VA Maximum () Pole Terminal Block Connector For Power In Operating Temperature 0 F to 49 F () Pole Terminal Block For Discharge Temperature Sensor Connection Operating Humidity 0-90% RH Non-Condensing Communications RS ,600 Baud Inputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Temperature Sensor Applications () Pole Terminal Block for Occupancy or Window Switch Terminals Outputs: () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: Orion-OE74-03-OR-0A.doc Page of

6 OE74-03-OR Pressure Dependent Package Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA Certified and/or culus acc. to UL A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty of Form: Orion-OE74-03-OR-0A.doc

7 B P 0uF D7 D9 + J R30 R9 R8 R R5 R5 OFF R5 R5 LOOP BAUD C V C4 R6 D3 BAUD - HI D D 0uF V4 P3 V OE OR Pressure Independent Package Description The OE OR Pressure Independent Package with Terminal Block connectors provides the latest solution for zone damper applications. The package includes the OE36-3I-OR mounted in a plastic enclosure, the OE8-0 Zone Damper Actuator with cable, and an Airflow Sensor. OCC. SWITCH BIN TB4 C34 R60 DUCT R59 SENSOR TMP TB DIGITAL SPACE C5 R4 R3 +V 5.64 TB6 SPACE SENSOR R37 ADJ TMP R37 R0 R TB3 LO HI LO 3.3V 5.0V AIRFLOW TP YS0588 REV OE8 Damper Actuator Mounting The Package is very easy to mount on your terminal unit. There are four conduit holes that are sized for ½ conduit fittings that are provided for as part of the mounting plate that is on the Orion series of zone dampers - OE50-XX-PT or OE5-XX- PT. The rectangular damper kit also has four ½ conduit knockouts in its enclosure as well. Detailed mounting and installation instructions are provided with each Package C9.00uF E-BUS COMM POWER INPUT R+ SH T- 4 VAC 4 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED WattMaster Label #L037 Rev.: 0A OCCUPIED SWITCH E-BUS CONNECTORS COMM POWER APP HB WDOG OS HB STAT STAT ON ADDRESS BIN DUCT TEMP SENSOR TMP DIGITAL SPACE SENSOR + ADDRESS ON ADDRESS SWITCH SW 6 3 AUX HEAT + VDC VDE VDC VAC ~ ANALOG SPACE SENSOR OE36-3I-OR P.I. VAV /ZONE CONTROLLER C US AUXILIARY HEAT RELAY CONTACT RATING IS AMP 4 VAC TB5 R4 R CCW C5 CW 0 ACTUATOR ADJ TMP COM HEAT ACTUATOR CONNECTOR SERIAL # Modular Jack Connection 8 Long Modular Cable Technical Data OE36-3I-OR Pressure Independent General Specifications: Inputs: Supply Power 4 VAC () 3 Pole Terminal Block Connector For Comm In & Out Consump- Power tion Operating Temperature Operating Humidity 6 VA Maximum () Pole Terminal Block Connector For Power In 0 F to 49 F 0-90% RH Non-Condensing () Pole Terminal Block For Discharge Temperature Sensor Connection () Pole Terminal Block for Occupancy or Window Switch Terminals Communications RS ,600 Baud Hi & Lo Pressure Tube Fittings For Integral Air Flow Sensor (P.I. s Only) Inputs: Outputs: () 3 Pole Terminal Block for Analog Room Temperature Sensor Applications () 4 Pole Terminal Block for E-BUS Digital Room Sensor Applications () E-BUS Connectors For Connection of Expansion Module and/or E-BUS Digital Room Temperature Sensor () RJ-45 Modular Connector for Connection of Actuator () Pole Terminal For Connection Of Auxiliary Heat Contactor WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty Form: Orion-OE OR-A.doc Page of

8 OE OR Pressure Independent Package Technical Data OE8-0 Zone Damper Actuator Power Supply 4VAC 0% 50/60HZ Angle of Rotation Max. 95, Adjustable Life Cycle Rating.5 Million Cycles with Mechanical Stops Power Consumption 3 VA Maximum Power Connection RJ- Modular Jack Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Quality Standard ISO 900 Condensing Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Direction of Rotation Reversible with Switch Overload Protection Electronic Throughout 0 to 95 Rotation Agency Listings UL873 listed CSA Certified and/or culus acc. to UL A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EEC and 006/95/EC Feedback Signal 0K ohm W Potentiometer Torque Minimum 45 in-lb Running Time 80-0 Seconds. Weight. lb. WattMaster reserves the right to change specifications without notice. All Dimensions are in inches. Three Year Warranty of Form: Orion-OE OR-0A.doc

9 OE50-XX-PT Round P.D. Zone Damper Assembly W/ Terminal Block Connectors Description The OE50-XX-PT Round Pressure Dependent Zone Damper Assembly with terminal block connectors consists of a round air damper and the OE74-0P-VAVZ Package with terminal block wiring connectors. An optional Expansion Module (OE35-03) is available for control of reheat, auxiliary heat and/or control of series or parallel flow fan terminal units. The board is microprocessor based and communicates with the HVAC unit controller on the Orion local communications loop. The monitors the space temperature and allocates the proper airflow into its assigned space to achieve the desired comfort and ventilation levels. Damper Blade And Shaft P.D. Zone Damper Housing / Foil Face Insulation Damper Actua Pressure Dependent Zone Dampers are used in air conditioning systems that do not require pressure independent airflow control. If your system requires pressure independent control of Control Base Cover the airflow, see the OE5-XX-PT Round Pressure Independent Zone Damper submittal sheet for the correct specifications. All dampers are tested for performance in accordance with AMCA 500D standards. Mounting The Zone Damper Assembly should be mounted according to standard duct installation practices with airflow direction as shown in the illustration above. After installation of the Zone Damper in the ductwork, insulation should be applied around any remaining un-insulated surface on the damper inlet and outlet. The Zone Damper should be mounted so that the control enclosure is positioned to the left or right side of the ductwork with the control enclosure in a vertical plane. Do not mount the Zone Damper Assembly with the control enclosure on the top or bottom of the ductwork. Adequate clearance should be maintained between the control panel and any obstruction to allow for removal of the control panel cover and access to the controls. Technical Data OE50-XX-PT Round Pressure Dependent Zone Damper Assembly W/ Terminal Block Connectors : Air Damper Construction: Supply Power 4 Volt AC Damper Body 0 Ga. Galv. Steel Power Consumption 6 VA Maximum Damper Blade Round -8 Ga. Galv. Steel Operating Temperature 35 F to 5 F Damper Bearings Stainless Steel Operating Humidity 0-90% RH Non-Condensing Damper Seal EPDM Rubber Gasket Communications RS Baud Leakage < 0 CFM Per Sq. 4 SP Insulation ½ Foil Faced Fiberglass Inputs: Dimensions: Room Temperature Sensor Air Damper Model A B C Setpoint Adjustment OE50-06 (6 ) Actuator Position Feedback OE50-08 (8 ) Communication Connectors: 3 Position Terminal Block OE50-0 (0 ) Expansion E-BUS Port for Auxiliary Relay Board OE50- ( ) E-BUS Port for E-BUS Digital Room Sensor and CO Sensor OE50-4 (4 ) Actuator Port for Connection to Damper Actuator OE50-6 (6 ) WattMaster reserves the right to change specifications without notice inches. Three Year Warranty On Electronic Components All Dimensions are in One Year Warranty On Air Damper Form: Orion-OE50XX-PT-RndDmpr-0A Page of

10 OE50-XX-PT Round P.D. Zone Damper Assembly W/ Terminal Block Connectors Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used to select Zone Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce airflow noise problems, duct pressures generally should not exceed W.C. Primary trunk ducts that are used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With larger trunk ducts, it is easier to assure relatively constant pressure to each Zone Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Zone Dampers in the areas above corridors to reduce the noise in the space and to facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Using the maximum acceptable velocity for a branch duct (typically FPM for minimal noise), find the smallest Zone Damper that will deliver the required CFM as determined by the load program. Locate the branch velocity used in the duct design program in the left hand column of the Zone Damper Selection Data table. Move across the table and find the Zone Damper, which will provide the acceptable CFM to meet the zone airflow requirements. Note: Compare the Zone Damper size selected against the duct size to determine if the next size up or down will provide acceptable performance without requiring a transition fitting. Up to a maximum of two Slaved Zone Dampers may be slaved together with the main Zone Damper for large zones. This design should be reserved only for situations when it is not practical to use a single Zone Damper. See the Pressure Independent Zone Damper submittal sheet submittal sheet for information regarding application and selection of Round Slaved Zone Dampers. Zone Damper Selection Data Zone Damper Round Duct Size (Area Ft ) 6 (0.96) OE50-XX-PT Round Pressure Dependent Zone Damper Assembly W/ Terminal Block Connectors 8 (0.349) 0 (0.545) (0.785) 4 (.069) 6 (.396) Velocity Through Damper FPM Airflow Through Damper - CFM ( P S inches W.C. w/ Damper Full Open) (0.05) 45 (0.05) 94 (0.035) 343 (0.045) 39 (0.065) (0.05) (0.035) 6 (0.035) 698 (0.043) (0.05) 88 (0.0) 954 (0.034) 090 (0.040) (0.05) 78 (0.00) 374 (0.030) 570 (0.040) (0.05) ) 87 (0.030) 38 (0.040) (0.05) 094 (0.00) 443 (0.05) 79 (0.030) WattMaster reserves the right to change specifications without notice Form: Orion-OE50XX-PT-RndDmpr-0A Page of

11 OE5-XX-PT Round P.I. Zone Damper Assembly W/ Terminal Block Connectors Description The OE5-XX-PT Round Pressure Independent Zone Damper Assembly with terminal block connectors consists of a round air damper with air flow pickup cross and the OE744-0P-VAVZ Zone Package (including air flow sensor) with terminal block connectors. An optional Expansion Module (OE35-03) is available for control of reheat, auxiliary heat, and/or control of series or parallel flow fan terminal units. Damper Blade And Shaft P.I. Zone Damper Housing / Foil Face Insulation Damper Actuator The board is microprocessor based and communicates with the HVAC unit controller on the Orion local communications loop. The monitors the space temperature and allocates the proper airflow into its assigned space to achieve the desired comfort and ventilation levels. Pressure Independent Dampers are used in air conditioning systems that require pressure independent airflow control. If your system requires pressure dependent control of the airflow, see the Air Flow Pickup Cross Control Base Cover OE50-XX-PT Round Pressure Dependent Zone Damper submittal sheet for the correct specifications. All dampers are tested for performance in accordance with AMCA 500D standards. Mounting The Zone Damper Assembly should be mounted according to standard duct installation practices with airflow direction as shown in the illustration above. After installation of the Zone Damper in the ductwork, insulation should be applied around any remaining un-insulated surface on the damper inlet and outlet. The Zone Damper should be mounted so that the control enclosure is positioned to the left or right side of the ductwork with the control enclosure in a vertical plane. Do not mount the Zone Damper Assembly with the control enclosure on the top or bottom of the ductwork. Adequate clearance should be maintained between the control panel and any obstruction to allow for removal of the control panel cover and access to the controls. Technical Data OE5-XX-PT Round Pressure Independent Zone Damper Assembly W/ Terminal Block Connectors Zone : Air Damper Construction: Supply Power 4 Volt AC Damper Body 0 Ga. Galv. Steel Power Consumption 6 VA Maximum Damper Blade Round -8 Ga. Galv. Steel Operating Temperature 35 F to 5 F Damper Bearings Stainless Steel Operating Humidity 0-90% RH Non-Condensing Damper Seal EPDM Rubber Gasket Communications RS Baud Leakage < 0 CFM Per Sq. 4 SP Inputs: Insulation ½ Foil Faced Fiberglass Air Flow Sensor Dimensions: Room Temperature Sensor Air Damper Model A B C Setpoint Adjustment OE50-06 (6 ) Actuator Position Feedback OE50-08 (8 ) Communication Connectors: 3 Position Terminal Block OE50-0 (0 ) Expansion E-BUS Port for Auxiliary Relay Board OE50- ( ) E-BUS Port for E-BUS Digital Room Sensor and CO Sensor OE50-4 (4 ) Actuator Port for Connection to Damper Actuator OE50-6 (6 ) WattMaster reserves the right to change specifications without notice All dimensions are in inches. Three Year Warranty On Electronic Components One Year Warranty On Air Damper Form: Orion-OE5XX-PT-RndDmpr-0A Page of

12 OE5-XX-PT Round P.I. Zone Damper Assembly W/ Terminal Block Connectors Zone Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used to select Zone Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce airflow noise problems, duct pressures generally should not exceed W.C. Primary trunk ducts that are used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With larger trunk ducts, it is easier to assure relatively constant pressure to each Zone Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Zone Dampers in the areas above corridors to reduce the noise in the space and to facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Using the maximum acceptable velocity for a branch duct (typically FPM for minimal noise), find the smallest Zone Damper that will deliver the required CFM as determined by the load program. Locate the branch velocity used in the duct design program in the left hand column of the Zone Damper Selection Data table. Move across the table and find the Zone Damper, which will provide the acceptable CFM to meet the zone airflow requirements. Note: Compare the Zone Damper size selected against the duct size to determine if the next size up or down will provide acceptable performance without requiring a transition fitting. Pressure Independent Zone Dampers may not be slaved together with Slaved-Zone Damper Assemblies. If more than one damper is required for a zone, all dampers must be selected as pressure dependent. See the Pressure Dependent Zone Damper submittal sheet and Slaved-Zone Damper submittal sheets for selection of master/slave damper configurations. Zone Damper Selection Data Zone Damper Round Duct Size (Area Ft ) Velocity Pressure (Air Flow Probe K Factor) 6 (0.96) OE5-XX-T Round Pressure Independent Zone Damper Assembly W/ Terminal Block Connectors 8 (0.349) 0 (0.545) (0.785) 4 (.069) 6 (.396) Velocity Through Damper FPM Airflow Through Damper - CFM ( P S inches W.C. w/ Damper Full Open) (0.05) 45 (0.05) 94 (0.035) 343 (0.045) 39 (0.065) (0.05) (0.035) 6 (0.035) 698 (0.043) (0.05) 88 (0.0) 954 (0.034) 090 (0.040) (0.05) 78 (0.00) 374 (0.030) 570 (0.040) (0.05) ) 87 (0.030) 38 (0.040) (0.05) 094 (0.00) 443 (0.05) 79 (0.030) WattMaster reserves the right to change specifications without notice Form: Orion-OE5XX-PT-RndDmpr-0A Page of

13 OE PT P.D. Rectangular Damper Kit w/terminal Blocks Description The OE PT P.D. Rectangular Damper Kit with Terminal Blocks provides the latest solution for rectangular zone damper applications. The Rectangular Damper Kit is used in conjunction with rectangular dampers for applications where rectangular dampers are specified or required because of space limitations or job requirements. P.D. Zone Enclosure Base Damper Actuator Enclosure Cover The Rectangular Damper Kit includes the OE74-0P-VAVZ Package mounted in a metal enclosure. The rectangular dampers may be purchased from WattMaster or you may get them from the supplier of your choice. For proper control, WattMaster recommends the use of low leakage opposed blade dampers. The maximum allowable damper face area for the Rectangular Damper Kit is 6 sq. ft. Mounting Before mounting the Rectangular Damper Kit, the rectangular damper should be mounted in the ductwork according to standard duct installation practices. The damper should be mounted so the damper shaft turns in a clockwise direction to open the damper. The Rectangular Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self-tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out to allow for damper shaft lengths, which extend past the enclosure depth. When mounting the Rectangular Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring installation. Component View Dimensional Info Technical Data : OE PT Rectangular P.D. Damper Kit Features: Supply Power 4 Volt AC Sensors Uses Standard Room Sensor or E-BUS Temp/Humidity Power Consumption 6 VA Maximum Enclosure Material Galvanized Steel Operating Temperature 0 F to 49 F Zone Factory Mounted Operating Humidity 0-90% RH Non-Condensing Zone Actuator Factory Mounted E-BUS Communications RS-485, 57,600 Baud Actuator Rating 45 in/lbs (6 ft Damper Area Max.) Inputs: Actuator Shaft Size Self-Centering - Adjustable from 3 / 8 to ½ Occupied or Window Switch Actuator Direction Reversible with Switch Wire Terminals for E-BUS Digital Room Sensor E-BUS Port for E-BUS Digital Room Sensor of Rotation Outputs: Discharge Temperature Sensor Wire Terminals E-BUS Ports for Expansion Board and/or E-BUS Sensor Actuator Position Feedback Modular Port And Cable For Connection to Actuator WattMaster reserves the right to change specifications without notice Three Year Warranty On Electronic Components One Year Warranty On Air Damper Form: Orion--OE PT-Rect-PD-VAVZP-0A.doc Page of

14 OE59 - Rectangular Damper Description The OE59 Rectangular Damper is used in applications where rectangular duct is specified or required because of space limitations or job requirements. The Rectangular Damper utilizes opposed blades of airfoil design for improved air flow control. The Rectangular Damper frame is made of.080 thick extruded aluminum. The blades are also made of extruded aluminum. Blade pins are 7/6 hexagon shaped aluminum fixed to a Celcon inner bearing rotating within a polycarbonate outer bearing inserted in the damper frame. The Damper linkage is mechanically assembled and located in the damper frame. The linkage components are constructed of aluminum, zinc and nickel plated steel. Blade gaskets are made of extruded EPDM material and are secured within an integral slot on the blade. Jamb seals are of extruded TPE material for low leakage through the damper when closed. The control shaft is / diameter hexagon shaped rod and can be extended 9 past the damper frame for connection to the damper actuator. The damper shaft is shipped retracted into the frame area and must be adjusted to the required length in the field. Opposed Blade Profile Flanged to Duct Installation Mounting Dimensional Data The Rectangular Damper should be mounted in the ductwork according to standard duct installation practices. The rectangular damper should be selected for the nominal inside duct size. All Rectangular Dampers are supplied with flanges all around damper frame, making the overall damper width and height larger than the nominal inside duct size thus providing for external flange mounting to ductwork. The damper shaft is shipped retracted into the damper frame. Loosen the two nuts on the U-bolt that secures the damper shaft to the damper blade and adjust to length. It is recommended that the shaft length be adjusted so approximately 4 of shaft extends beyond the inside of the damper frame. Retighten the two nuts on the U-bolt that secures the damper shaft to the blade. After installation of the Rectangular Damper to the ductwork, it is recommended that insulation be applied around any non-insulated surface on the ductwork where the Rectangular Damper was installed. Damper Sizing Use a load program to determine the peak load for each zone. These calculations will be used in selecting the appropriate Rectangular Damper sizes. The Orion Systems utilize a typical low pressure duct design. To reduce noise problems, duct pressures should not exceed W.C. Primary trunk ducts used with Orion systems should not be undersized. This is especially true of pressure dependent systems. With pressure independent systems this is not as critical. With larger trunk ducts, it is easier to assure relatively constant pressure to each Rectangular Damper. Runs should be as short as possible, and the trunk duct system kept as symmetrical as possible to facilitate system balancing. Wherever possible, run the trunk ducts above corridors and locate the Rectangular Dampers above corridors to reduce the noise in the space and facilitate service of the valves. Trunk ducts should be sized for no more than 0. W.C. drop per 00 ft. of duct, and a maximum duct velocity of 000 FPM. Form: ORION-OE59-RectDmpr-Sub-0B.doc Page of

15 OE59 - Rectangular Damper Using the maximum acceptable velocity for a branch duct (typically FPM for minimal noise), find the smallest damper that will deliver the required CFM as determined by the load program. Locate the required CFM on the Rectangular Damper Selection Data table below. This table is based on an airflow velocity of 000 FPM across the damper. This is the recommended velocity for quiet operation and normal pressure drop through the damper. When space considerations or design criteria dictate, dampers may be selected for other face velocities by using the multipliers listed in the notes associated with the table. Move across the table and find the damper selection, which will provide the required CFM and fit within the ceiling area where the damper will be located. Many size selections are possible for a given CFM. Pressure drop across the damper is shown in parenthesis below the CFM. Rectangular Damper Selection Data Damper Height B Damper Width A Airflow Data with Full Open Damper 000 FPM Velocity ( P S - inches 000 FPM Velocity) 8 40 (0.6) 0 50 (0.0) 560 (0.07) (0.05) (0.04) (0.03) (0.03) (0.0) 590 (0.07) 650 (0.05) 770 (0.03) 890 (0.03) 980 (0.03) (0.07) 690 (0.05) 730 (0.03) (0.05) 800 (0.03) (0.04) 90 (0.03) (0.03) (0.03) Form: ORION-OE59-RectDmpr-Sub-0B.doc Page of NA NA 480 NA NA NA NA NA NA NA 480 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA WattMaster reserves the right to change specifications without notice Notes:. The table above is calculated based on 000 FPM velocity across the full open damper. For other velocities use the following multipliers to obtain the correct CFM: 500 FPM = 0.5, 500 FPM =.5, 000 FPM =.0. It is recommended the damper velocity does not exceed 500 FPM for quiet operation.. Pressure drop ( P S) is based on 000 FPM Velocity. Any pressure drop less than 0.0 W.C. is shown as.

16 OE737 - Bypass Rectangular Damper Kit Description The OE737 Rectangular Bypass Damper Kit mounts to an OE59 Rectangular Damper and controls duct static pressure to insure proper system airflow. The Rectangular Bypass Damper is controlled by the Orion HVAC Unit. The Unit modulates the Rectangular Bypass Damper in response to the duct static pressure based on a signal received from a static pressure sensor located in the main system ductwork. The Rectangular Bypass Damper Kit is used in conjunction with rectangular dampers for applications where rectangular dampers are specified or required because of space limitations or job requirements. The rectangular dampers may be purchased from WattMaster or you may get them from the supplier of your choice. For proper control, WattMaster recommends the use of low leakage opposed blade dampers. The maximum allowable damper face area for the Rectangular Bypass Damper Kit is 6 sq. ft. The Rectangular Bypass Damper Kit comes packaged with the Damper Actuator and Wiring Interface pre-mounted in a galvanized steel enclosure. Each kit is supplied with mounting hardware and installation instructions. For applications where CFM or space requirements dictate the use of more than a single bypass damper, up to additional bypass dampers can be slaved together. No other components are required. Each bypass is wired to the other bypass damper(s) by means of the Wiring Interface. Mounting Before mounting the Rectangular Damper Kit, the rectangular damper should be mounted in the ductwork according to standard duct installation practices. The damper should be mounted so the damper shaft turns in a clockwise direction to open the damper. The Rectangular Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out to allow for damper shaft lengths, which extend past the enclosure depth. When mounting the Rectangular Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring. Technical Data OE737 Rectangular Bypass Damper Kit Supply Power 4 Volt AC Enclosure Base Ga. Galv. Steel Power Consumption 3.0 VA Maximum Enclosure Cover Ga. Galv. Steel Operating Temp - F to F Conduit Openings Top - () ½ & ¾ Comb. Knockouts Operating Humidity 90% RH Non-Condensing Bottom - () ½ & ¾ Comb. Knockouts Actuator Feedback 0Kohm, W Potentiometer Shaft Clearance Front - () ½ & ¾ Comb. Knockout Actuator Rating 35 in/lbs (6 ft Damper Area Max.) Controls Factory Mounted Inside Enclosure Mounting Hardware (4) Self Tapping Screws Controls Access Cover is Removable by Instructions Included with Each Kit Loosening Screws Three Year Warranty WattMaster reserves the right to change specifications without notice Form: Orion-OE737-RectBypKit-Sub-0B Page of

17 Description The OE738 Rectangular Slaved- Damper Kit provides a new solution for rectangular damper applications. The OE738 Rectangular Slaved- Damper Kit is used in conjunction with rectangular dampers for applications in systems when it is not possible or practical to use a single large Rectangular Air Damper to satisfy the zones CFM requirements. OE738 - Slaved- Rectangular Damper Kit The rectangular dampers may be purchased Component View from WattMaster or you may get them from the 5.75 supplier of your choice. For proper airflow control, WattMaster recommends the use of low 3.5 leakage opposed blade dampers. The Rectangular Slaved- Damper Kit is supplied 8.0 with the slave wiring interface card and actuator factory mounted in a sheet metal enclosure. A total of two Slaved- Air Dampers may.5 be used in conjunction with a master Rectangular Damper Kit. The Rectangular Slaved- Air Damper(s) are wired in Dimensional Data parallel with the master Rectangular Damper Kit and track the movement of the master Rectangular Damper. Connection to the master Rectangular Damper Kit requires a Slave Wiring Adapter Kit, part # OE67 which is supplied with each Rectangular Slaved- Damper Kit. The kit connects the zone controller on the master to the master actuator and provides wiring terminals for wiring to the Rectangular Slaved- Damper Kit(s). Only one Slaved Wiring Kit is required for each Slaved- system. Each kit is supplied with mounting hardware and installation instructions. Mounting The rectangular damper should be mounted in the ductwork according to standard duct installation practices before installing the Rectangular Slaved- Damper Kit. The Rectangular Slaved- Damper Kit is simply slid over the damper shaft, the actuator shaft collar setscrews tightened and the supplied self tapping screws are used to mount the enclosure to the ductwork. Detailed mounting and installation instructions are provided with each kit. A knockout is provided in the front access cover, which can be punched out for damper shaft lengths which extend past the enclosure depth. When mounting the Rectangular Slaved- Damper Kit, be sure to allow clearance for removal of the access cover. Conduit knockouts are provided in the top and bottom of the enclosure for simplified wiring installation. Technical Data Actuator: OE 738 Rectangular Slaved-Zone Damper Kit OE 738 Damper Kit Features: Supply Power 4 Volt AC Enclosure Base Ga. Galv. Steel Power Consumption 3.4 VA Maximum Enclosure Cover Ga. Galv. Steel Operating Temperature 0 F to 49 F Conduit Openings Top - () ½ & ¾ Comb. Knockouts Operating Humidity 90% RH Non-Condensing Bottom - () ½ & ¾ Comb. Knockouts Shaft Clearance Front - () ½ & ¾ Comb. Knockout Inputs: Controls Factory Mounted inside the Enclosure Actuator Position Feedback Mounting Hardware Supplied with (4) Self Tapping Screws Instructions Included with Each Kit Controls Access Cover is Removable by Loosening Screws Actuator Rating 35 in/lbs (6 ft Damper Area Max.) WattMaster reserves the right to change specifications without notice Three Year Warranty Form: Orion-OE738-RectSlvZoneKit-SUB-0B Page of

18 Description The OE8-03 Slaved Damper Kit consists of an OE8 Damper Actuator, () PL084 Slave Wiring Interface Boards and () 8 Long Modular Cables. The OE8 Actuator is a shaft mounted, floating point control actuator. The actuator is a 4VAC/4VDC model with a 0K ohm feedback signal for position monitoring. Wiring connection to the actuator is by means of a modular phone cable connector located on the actuator cover. The actuator is rated for 45 inlb. of torque. All actuators are electronically protected against overload. The angle of rotation is mechanically limited to 95. When the end position of the actuator or damper is reached, the actuator automatically stops. For adjustment purposes, the gears can be manually disengaged by pushing the manual override button on the actuator cover. OE8-03 Slaved Damper Kit Applications The OE8-03 Slaved Damper Kit allows multiple dampers (up to total besides the master) to be connected to a master OE74-3-VAVZ or OE74-3-VAVZ P.D. Actuator Package. The OE8-03 Kit is typically used when larger CFM requirements dictate multiple dampers are used. One of the Interface Boards connects to the master via a modular cable. The other Interface Board connects to the Slave Damper Actuator. Three conductor wiring is then routed and connected between the two Interface Boards. For zones requiring more than one Slave Damper Kit a second one can be purchased and installed in the same manner. Technical Data OE8-03 Slaved Damper Kit Actuator Power 4VAC 0% 50/60HZ Actuator Angle of Rotation Max. 95, Adjustable Supply Actuator Life Cycle.5 Million Cycles with Mechanical Stops Rating Actuator Power 3 VA Maximum Power Connections RJ- Modular Jack Consumption Operating Temp - F to F Servicing Maintenance Free Operating Humidity 5 to 95% RH Non- Actuator Quality Standard ISO 900 Condensing Actuator Overload Protection Electronic Throughout 0 to 95 Rotation Actuator Agency Listings UL873 listed CSA Certified Actuator Feedback 0K ohm W Actuator Torque Minimum 45 in-lb. Signal Potentiometer Actuator Running 80-0 Seconds. Approx. Kit Weight. lb. Time PL084 Board () RJ- Modular Jacks PL084 Board () Wiring Terminal Blocks Three Year Warranty WattMaster reserves the right to change specifications without notice Form: Orion-OE8-03-SlvZoneDmprKit-Sub-0A.doc Page of

19 Worksheet Project Name: Local Loop Number: Directions: Estimate cable lengths from building mechanical plans and place in estimated cable length column beside each controller or board on loop. Select available cable lengths closest to estimated cable lengths and extensions for each controller or board on list and place checkmarks in these columns. Also Use this information for ordering correct quantity and length of modular or digital cables and extensions. Total each cable length column on each page and add both page totals together. Address Or Board Description, Location Or Tag Number Incoming Cable Length 3 Ft. 5 Ft. Available 40 Ft. 80 Ft. 0 Ft. E-0 Ft. E-0 Ft. Incoming Modular Or Digital Room Sensor Cable Length 5 Ft. Available Modular Or Digital Room Sensor See Notes Below 0 Ft. 5 Ft. 40 Ft. 80 Ft. 0 Ft. 60 Ft. N/A Power Comm Board Caution: Each board has a total of 4 branch circuits. No more N/A Power Comm Board than 6 modular devices are allowed per branch circuit. No more than 6 modular devices total can be connected to each N/A Power Comm Board 3 board. The longest total run per branch circuit is 40 Feet. N/A Power Comm Board Page Totals Notes:.) Available cable lengths with the prefix E (E-0 Ft. or E-0 Ft.) are extensions to be used in conjunction with another standard cable length to extend it to a desired length, they cannot be used by themselves without connection to a standard cable..) Available Modular Sensor cable lengths are provided in 5 Ft, 0 Ft., 5 Ft., 40 Ft. and 80 Ft. Lengths. To get longer lengths you can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between or greater than the standard cable sizes. Available Digital Sensor cable lengths are provided in 5 Ft., 0 Ft., 5 Ft., 40 Ft., 80 Ft., 0 Ft. and 60 Ft. sizes. You can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between the available sizes. It is recommended that you avoid this when using the Digital Sensor cable. The maximum allowable total cable length for Digital Sensor cables is 60 Ft. and should never be exceeded. Form: Orion-VAVZoneCableEst-All-A.doc Page of 77

20 Worksheet Project Name: Local Loop Number: Directions: Estimate cable lengths from building mechanical plans and place in estimated cable length column beside each controller or board on loop. Select available cable lengths closest to estimated cable lengths and extensions for each controller or board on list and place checkmarks in these columns. Also Use this information for ordering correct quantity and length of modular or digital cables and extensions. Total each cable length column on each page and add both page totals together. Address Or Board Description, Location Or Tag Number Incoming Cable Length 3 Ft. 5 Ft. Available 40 Ft. 80 Ft. 0 Ft. E-0 Ft. E-0 Ft. Incoming Modular Or Digital Room Sensor Cable Length 5 Ft. Available Modular Or Digital Room Sensor See Notes Below 0 Ft. 5 Ft. 40 Ft. 80 Ft. 0 Ft. 60 Ft Page Totals Totals For Both Pages Notes:.) Available cable lengths with the prefix E (E-0 Ft. or E-0 Ft.) are extensions to be used in conjunction with another standard cable length to extend it to a desired length, they cannot be used by themselves without connection to a standard cable..) Available Modular Sensor cable lengths are provided in 5 Ft, 0 Ft., 5 Ft., 40 Ft. and 80 Ft. Lengths. To get longer lengths you can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between or greater than the standard cable sizes. Available Digital Sensor cable lengths are provided in 5 Ft., 0 Ft., 5 Ft., 40 Ft., 80 Ft., 0 Ft. and 60 Ft. sizes. You can join Modular cables together using the MS00009 Modular Room Sensor Cable Coupler to extend the cables to a desired length in between the available sizes. It is recommended that you avoid this when using the Digital Sensor cable. The maximum allowable total cable length for Digital Sensor cables is 60 Ft. and should never be exceeded. Form: Orion-VAVZoneCableEst-All-A.doc Page of 78

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

CCS Zone/Bypass Damper Assembly

CCS Zone/Bypass Damper Assembly Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

YCCS Zone/Bypass Damper Assembly

YCCS Zone/Bypass Damper Assembly YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper Assemblies are zone control and pressure control devices that

More information

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE: ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount

More information

GM Series Direct Coupled Actuator

GM Series Direct Coupled Actuator GM Series Direct Coupled Actuator Minimum 3 in-lb torque** For damper areas up to 8 sq-ft* Applications Linkage is part of inlet vane assembly supplied by manufacturer. Actuator is mounted to vortex frame.

More information

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

YCCS Zone/Bypass Damper Assembly

YCCS Zone/Bypass Damper Assembly YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper are zone control and pressure control devices that include

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

MC-351, 421, 431, MC-4311

MC-351, 421, 431, MC-4311 MC-35, 42, 43, MC-43 Three-Wire, Two Position Actuators General Instructions Applications For two-position operation of dampers or valves in heating, ventilating and air-conditioning systems and similar

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type 1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

Laboratory Room Controller

Laboratory Room Controller Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space

More information

LF Series At A Glance

LF Series At A Glance LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional

More information

Commercial Actuator Selection Chart Non-Spring Return

Commercial Actuator Selection Chart Non-Spring Return Commercial Actuator Selection Chart Non-Spring Return Control Signal Position Feedback Torque Aux. Switches Actuator Model 4 VAC Power Input On/Off Tri-State Floating 0 to 0 VDC 0 to 0 ma* 4 to 0 ma 0

More information

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4. TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare Accutrol, LLC Product Sheet AVC6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare AHR Expo AWARDS WINNER epi Innovative features for the AVC6000! Intuitive Graphical User Interface

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

How to Select the RE Industrial Actuator Part Number

How to Select the RE Industrial Actuator Part Number How to Select the RE Industrial Actuator Part Number RE 10 T F 2 Torque (in-lb) 1.5 150 3 300 6 600 8.5 850 10 1000 15 1500 20 2000 25 2500 30 3000 Reversing Electronic Torque Maximizer (optional) Increases

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MERIDIAN PLUS CONTENTS TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...3 ZONE MANAGER ADDRESSING.................. 5 COMMUNICATIONSLOOPS...6 COMMUNICATIONS LOOP WIRING

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

Powers TM Controls EA 338 Electronic Actuator

Powers TM Controls EA 338 Electronic Actuator Powers TM Controls Technical Instructions Document No. 155-136P25 EA 338-1 Description Features 24 Vac power supply. The s are used with floor mount linkage kits to operate dampers in HVAC installations.

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

RETROFIT TERMINAL UNITS

RETROFIT TERMINAL UNITS GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

M9216 Series Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators *34636461G* 34-636-461, Rev. J Installation Instructions M9216 Issue Date October 217 M9216 Series Electric Spring Return Actuators Installation IMPORTANT: The M9216 Series actuator is intended to control

More information

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control

More information

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules Technical Specification Sheet Document No. 149-855 November 04, 2015 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules NOTE: The 570-8xxPA BACnet laboratory controllers have new 67xx

More information

ZG106 or ZG 107 bracket

ZG106 or ZG 107 bracket NF Series Spring Return Direct Coupled Actuator Minimum 60 in-lb torque For damper areas up to 15 sq-ft* Applications K4-1 US Clamp ZG106 or ZG 107 bracket Mount directly to 1.05 jackshafts with accessory

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) 3/4 Centered (Field Selectable) NF24-SR (-S) US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for 2 to 1 VDC, or 4 to ma Control Signal. Output Signal of 2 to 1 VDC for Position Indication Torque min. 6 in-lb, for control

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information

PIM Pressure Independence Module

PIM Pressure Independence Module PIM Pressure Independence Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independence Module is a modulating static pressure controller/actuator that allows

More information

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare Accutrol, LLC Product Sheet AVT6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare Innovative features for the AVT6000! AHR Expo AWARDS WINNER Intuitive Graphical User Interface

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

TSS Single-Duct VAV Terminals

TSS Single-Duct VAV Terminals TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION SIG DET RDY SND REC PWR INSTALLATION INSTRUCTION MERIDIAN BASIC CONTENTS Fan H E A T I N G C O O L I N G F IL T E R Mixed Air Outside Air Exhaust Air TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...2

More information

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18) AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position) Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position) Document No. 155-308P25 EA 599-14 Description Features Application The Powermite 599 MT Series SQS85.53U Electronic

More information

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Venturi FX VFX Series v100 Issue Date: 11/22/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety Precautions... 1 Caution to Contractors...1

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

FSAF24(-S) US, FSAF120(-S) US

FSAF24(-S) US, FSAF120(-S) US FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

PIM Pressure Independent Module

PIM Pressure Independent Module PIM Pressure Independent Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independent Module is a modulating static pressure controller/actuator that allows

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 The M9208-xxx-x Series Electric Spring Return Actuators provide control of dampers in Heating,

More information

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007 Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007 Belimo Project: 1100 Peachtree, Atlanta, Georgia Control Valve Product Range Electronic

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4) MOEL COE UCT SHAPE = Round = Rectangular = Flat Oval PROBE MATERIAL = Aluminum/ABS = CPVC & ABS = 0SS = High Temp SS (50 F / C Max) PROBE QUANTITY = = s = s = s SENSORS PER PROBE = Sensor per = Sensors

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMX4- (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMX4- LMX4--T Application For on-off and floating point

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings

More information

2520- EC Motor Speed Controller

2520- EC Motor Speed Controller 2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:

More information

OE & OE Digital Room Sensor

OE & OE Digital Room Sensor The OE217 series of Touch Screen Digital Room Sensors are used to sense Space Temperature only or Space Temperature & Space Humidity. The OE217-00 is a Space Temperature Sensor only and the OE217-01 is

More information