INSTALLATION INSTRUCTION

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTION"

Transcription

1 SIG DET RDY SND REC PWR INSTALLATION INSTRUCTION MERIDIAN BASIC CONTENTS Fan H E A T I N G C O O L I N G F IL T E R Mixed Air Outside Air Exhaust Air TIPS BEFORE BEGINNING INSTALLATION ZONEMANAGER...2 UNICATIONS...5 UNICATIONS WIRING OVERVIEW BYPASS DAMPER ZONEDAMPERS...7 MOUNTING...7 ZONECONTROLLERS...8 ZONESENSORS...11 SUPPLY AIR TEMPERATURE SENSOR RETURN AIR TEMPERATURE SENSOR OUTSIDE AIR TEMPERATURE SENSOR STATICPRESSURESENSOR...12 AUXILIARY RELAY BOARD FOR ZONE CONTROLLERS...13 ZONE CONTROLLER AUXILIARY RELAY BOARD OPERATION...14 LINKINTERFACE...14 APPENDIX AC Line Computer (Optional) Remote Link (Optional) CommLink II (Optional) Outside Air Temperature Avoid Direct Sunlight 24 VAC Ground Supply Air Temperature Meridian Basic Zone Manager Typically Mounted at the HVAC Unit Modulating Bypass Damper Zone Damper Zone Controller Static Pressure & Pickup Tube Local Communication Loop Zone #1 Temperature Up To 16 Zones Return Air Supply Air Duct Zone Damper Zone Controller Return Air Zone #2 Temperature With Override and Setpoint Adjust To Other Meridian Basic Zone Controllers

2 SIG DET RDY SND REC PWR TIPS BEFORE BEGINNING INSTALLATION Take a few moments to review the following before beginning installation of the Meridian System. See Figure 1. Familiarize yourself with all system components and review all documentation. Pay special attention to Cautions and Warnings since these may keep you from experiencing unnecessary problems. Before installing zone dampers, be sure to tag each damper with its appropriate location. A set of labels is included with this manual. It is also best to set the zone controller address switches before mounting in drop ceilings. Use the Zone Address Worksheet to list all zone locations. This will assist yougreatlywhensettingupthesystem. Be sure and install all wiring according to local, state, and national codes. Pay close attention to communication wiring since the most common mistakes are made in this area. Polarity is the most important rule. Make notes on your wiring diagrams as to which color wire you will be using on each terminal. When in doubt - ask! Contact your local Meridian distributor if you have any questions. The only dumb questions are the ones you don t ask. Remember - each electronic device contains only one puff of smoke. If you release it, you have voided the warranty! So please be careful and pay attention. ZONE MANAGER The Zone Manager may be installed in any convenient protected location. Observe the recommended environmental limitations for the Zone Manager (see Technical Data section of product data sheet) when choosing a location. The unit should be mounted with the display at eye level for easy viewing. When installing the Zone Manager with display and keypad, the cover must be removed. Use care not to damage the display while handling and protect the display from physical damage while removed. Fan H E A T I N G C O O L I N G F IL T E R Mixed Air Outside Air Exhaust Air Supply Air Temperature Return Air Outside Air Temperature Avoid Direct Sunlight Modulating Bypass Damper Static Pressure & Pickup Tube Return Air Supply Air Duct AC Line 24 VAC Ground Zone Damper Zone Controller Zone Damper Zone Controller Computer (Optional) Meridian Basic Zone Manager Typically Mounted at the HVAC Unit Local Communication Loop Zone #1 Temperature Up To 16 Zones Zone #2 Temperature With Override and Setpoint Adjust To Other Meridian Basic Zone Controllers Remote Link (Optional) CommLink II (Optional) FIGURE 1: MERIDIAN BASIC SYSTEM OVERVIEW 2 Installation Instruction - Meridian Basic

3 Grn Blk Red TB12 SIG 5V PRESSURE SENSOR JACK P1 C1 C2 D17 D18 D19 D20 D21 D22 D23 D24 ADD SW B NET The ribbon cable should be unplugged from the display board, which is mounted inside the front cover. The ribbon cable is keyed to prevent a reverse connection. The Zone Manager may be mounted without removing the controller from the enclosure or mounting plate. The unit is mounted by four (4) screws in the corners. Select the correct screws or other fasteners for the type of mounting material being utilized. Always remove power before connecting or disconnecting the ribbon cable which joins the display and keypad to the Zone Manager. Failure to observe this precaution may result in damage to the display or Zone Manager. Use extreme care not to damage any of the electronic components while mounting the enclosure. Mark the holes then remove the Zone Manager before drilling. Do not allow metal shavings to fall onto the circuit boards. Bypass Air Damper Actuator 0 1 Splice As Required LO HI Static Pressure Static Pick-up Supply Air Temp. Return Air Temp. Zone Manager Outdoor Air Temp. (See Note 4) POWER TB2 5.11V ADJUST PJ1 ANALOG INPUTS 12V SAT RAT OAT AUX1 Auxiliary Inputs ( Dry Contacts ) AUX2 Actuator Wiring Interface Feedback (BK) Gnd (WH) Open (YL) Close (GR) REC FDBK OPEN CLOSE V3 V4 V5 V6 NE5090 BYPASS OPEN BYPASS CLOSE G FAN Y1 Meridian COOL MODE 08/22/00 03:48PM TUE OCCUPIED NO ALARM(S) 7 LCD DISPLAY & KEYPAD A B C AUX3 RIBBON EXHAUST CONTACTS N.O. ANALOG OUTPUTS A1 A2 G TB2 EXP BUSS Aux3 Forced Occupied Mode Aux2 Filter Alarm To Relief / Exhaust Fans Aux1 Economizer Disable HVAC Unit R G Y1 Y2 W1 W2 Only FAN COOL1 COOL2 HEAT1 HEAT2 COOL 1 Y2 COOL 2 W1 HEAT 1 W2 HEAT 2 * 0 # D Rocker Down OFF > MADE IN U.S.A. C 1992 CABLE R5 R6 T SH RS-485 R DRIVER Economizer Actuator 5 U 4 Y2 3 Y1 2 1 COM BELIMO AF24-SR 133 IN-LB Line Voltage RS-485 Communications To Zone Controllers Local Loop WARNING! Use Extreme Care When Wiring Economizer Actuators Never Connect Or Disconnect Wiring With Power Applied! Never Apply Power If The Gnd ( 1 Com ) Terminal On The Actuator Is Not Connected. Belimo Actuator Wiring Shown. Consult Factory For Other Models Of Economizer Actuators. Some Actuators Require Isolation Transformers In Order To Prevent Damage To The Controller Board. FIGURE 2: ZONE MANAGER WIRING Installation Instruction - Meridian Basic 3

4 THE ZONE MANAGER REQUIRES THE FOLLOWING ELECTRICAL CONNECTIONS: 18 Gauge minimum unless otherwise noted: -SupplyVoltage...2Conductors -CommunicationsLoop...2Conductortwistedpairwithshield...(Belden#82760orequivalent) -Supply AirTemperature...(24ga.Min.)2Conductors -Return AirTemperature...(24ga.Min.)2Conductors -OutsideAirTemperature...(24ga.Min.)2Conductors -SupplyStaticPressure...(24ga.Min.)3Conductors -BypassDamper...4Conductors -HVACUnitControlWiring...R-Common...G-Fan...Y1-Cool1...Y2-Cool2... W1-Heat1... W2-Heat2 TIP After making all electrical connections, it is advised to unplug all terminal blocks on the Zone Manager until you are ready to begin the checkout procedure. This may help to prevent damage if wiring errors occur elsewhere in the system during installation or start-up. Your Meridian system will not work properly unless you set the Address switch correctly. Remember you must power down the Zone Manager after changing the address switch in order for the change to take effect. FIGURE 3: ZONE MANAGER ADDRESS SWITCH SETTING 4 Installation Instruction - Meridian Basic

5 UNICATIONS The communications network is a two wire shielded RS-485 loop. The loop is best connected in a daisy chain configuration, meaning the loop is connected from one controller to another. It is not necessary to sequentially address the zone controllers in relation to their location on the loop. Cable must be Belden No or equivalent. TIP Incorrect wiring of the communications loop is the most common mistake made during installation. Before beginning installation, write down the wire color used on each terminal connection and consistently maintain that color code. It is recommended that a continuous wire run be made between devices. Anytime a splice is made in the cable you increase your chance of problems. Make sure when you are inserting wires into the terminal blocks that strands of wire do not stick out and touch the next terminal. This could cause a short or erratic operation. UNICATIONS WIRING OVERVIEW The daisy chain is the best method for running a communications loop since there is only one starting point and one ending point (see Figure 4). Even though the daisy chain configuration is preferred, the star configuration can also be used. If required, a combination of the two can also be used. Remember, the best comm loop wiring is the one which utilizes the minimum number of ends while using the shortest wiring path. ZONE MANAGER START ( IF OPTIONAL LINK II IS NOT USED ) ZONE CONTROLLER LINE END ZONE CONTROLLER LINE ZONE CONTROLLER ZONE CONTROLLER NETWORK START LINE LINE SIG DET RDY SND REC PWR ZONE CONTROLLER ZONE CONTROLLER REMOTE LINK (OPTIONAL) COMP SDLNK LINE LINE LINK II (OPTIONAL) ZONE CONTROLLER ZONE CONTROLLER LINE LINE COMPUTER (OPTIONAL) FIGURE 4: UNICATIONS WIRING, DAISY-CHAIN CONFIGURATION Installation Instruction - Meridian Basic 5

6 NOTE The loop does not have to follow the controller address sequence. If sheet metal screws are used to mount the dampers, be certain that they do not interfere with the movement of the damper blade. If comm loop is not installed in conduit, be careful to position the cable away from high noise devices like fluorescent lights, transformers, VFD s, etc. Conduit is not required for comm loop wiring unless required by local codes. BYPASS DAMPER The bypass damper is mounted similar to the zone dampers. In fact the only difference in most cases is the size. The bypass damper should typically be sized for at least percent of the total design CFM. More than one bypass damper may be slaved together when it is not practical to use a single large damper. As with the zone dampers, it is often easier to mount the actuators before installing the bypass damper in the ceiling. See Figure 5 for damper actuator mounting instructions. Never depress the actuator clutch with power applied. Unplug the actuator cable before depressing the clutch and attempting to rotate the damper blade. The bypass damper should be installed as close as possible to the rooftop unit. If the fan system has the capability of producing static pressures which could damage ductwork, you must provide a manual reset, high pressure limit switch to cut-off the fan system in the event of high duct static. Do not use your Meridian System as a safety device! FIGURE 5: BYPASS ACTUATOR WIRING 6 Installation Instruction - Meridian Basic

7 ZONE DAMPERS Generally, zone dampers come preassembled with the actuator and Zone Controller. If not, the following instructions will assist you. MOUNTING In most cases, it is preferable to mount the damper actuator to the zone damper prior to mounting the damper in the ceiling. Before installing the zone damper, check for free movement of the damper blade by depressing the clutch on the damper actuator and moving the blade between it s full open and full closed positions. Any binding or incorrect adjustment should be corrected before mounting the damper. NOTE Direct acting actuators drive clockwise to open. Reverse acting actuators drive counter clockwise to open Never depress the actuator clutch with power applied. Unplug the actuator cable before depressing the clutch and attempting to rotate the damper blade. Do not force the damper blade as this can damage the gears in the damper actuator. Zone dampers should be securely hung using either wire cradles or metal strapping. While the dampers may be hung in any position, avoid sharp kinks in flexible duct to prevent airflow restrictions. If an air flow sensor is mounted, always be sure that the tips of the sensor are pointing down. The zone dampers should be insulated when installed in non-conditionedspacestoavoidsweating and to improve energy efficiency. If sheet metal screws are used to mount the dampers, be certain that they do not interfere with the movement of the damper blade. FIGURE 6: TYPICAL ACTUATOR MOUNTING Installation Instruction - Meridian Basic 7

8 ZONE CONTROLLERS The Zone Controllers are mounted in snap-track which is typically located in the control enclosure on each zone damper. Orient the board in the snap-track so that the actuator, flow sensor (optional), and auxiliary relay board (optional) cables will reach their respective connectors on the Zone Controller, if they are used. Press the board into the snaptrack carefully to avoid damaging any of the electronic components on the circuit board. To remove a board from the snap-track, carefully pull one edge of the snap-track away from the board with your fingers and remove the board. TIP After making all electrical connections, it is suggested that all terminal blocks on the Zone Controller be unplugged until you are ready to begin the checkout procedure. This may help prevent damage if wiring errors occur elsewhere in the system during installation or start-up. This is particularly important with the Zone Controllers since an error on one unit may prevent any of the others from working until the problem is found and corrected. Do not use any tools to pry the board loose. This will damage the board and/or the snap-track. When mounting the snap-track, be sure the heads of the screws do not protrude far enough to touch the bottom of the Zone Controller circuit board. Consider serviceability of the location when mounting the Zone Controllers. They should be easily accessible to facilitate servicing. Polarity is very important when connecting power to the controllers! The grounded side of the control transformer must be connected to the terminal labeled on the Zone Controller. If a single transformer is used to power more than one Zone Controller you must connect -to- and -to- on each zone controller. Failure to observe polarity will result in damage to one or more components in your system. TIP Use small stickers on the ceiling grid or tiles to help future service personnel locate system components. If you use small stickers from an office supply store, you can get different colors to code the location of various components. The Zone Controller requires the following electrical connections: Supply Voltage 2 Conductors Communications Loop 2 Conductor twisted pair with shield ( Belden #82760 or equivalent ) Room Temperature 2 Conductors for standard sensors 3 Conductors for sensors with setpoint adjustment Fan Terminal units / Auxiliary Heat 2-4 Conductors see wiring diagrams for (Optional) Aux. Relay board 8 Installation Instruction - Meridian Basic

9 FIGURE 7: ZONE CONTROLLER WIRING Installation Instruction - Meridian Basic 9

10 Set the Zone Controller Address Switch following the supplied addressing instructions. NOTE Ignore any markings or numbers on the switch. Usethischart! Incorrect addressing is the number one cause of communication problems. Check the addressing carefully. Remember, the Zone Controller only reads the switch during a power-up. If the address switch is changed, the unit must be turned OFF then ON before the new setting will be recognized. FIGURE 8: ZONE CONTROLLER ADDRESS SWITCH SETTINGS 10 Installation Instruction - Meridian Basic

11 ZONE SENSORS The zone sensor uses a patented flush mount design to isolate the temperature sensing element from the housing which mounts flush with the wall surface. Zone sensors should be located on an inside wall away from direct sunlight or heat producing equipment such as computers, copiers, etc. Such devices can adversely affect the accuracy of the sensor. Although the sensor eliminates most of the effects of thermal coupling to the walls, try to avoid walls which retain large amounts of thermal energy (such as marble or steel). Walls containing either cold or warm air currents should also be avoided whenever possible. Avoid locating the sensor in dead air areas of a room. This will result in slow response to temperature changes in the space. Mount the sensor approximately inches from the floor for best results. The zone sensor is designed to mount in a standard 2 by 4 inch electrical box. The sensor may be mounted directly into the drywall where electrical codes do not require low voltage wiring to be enclosed in conduit. A template is supplied with the sensor to facilitate cutting a hole of the correct size TIP Be careful when cutting the hole for the sensor or the plastic bezel of the sensor may not completely cover the opening. Connect the terminal labeled on the zone sensor to the terminal labeled on the Zone Controller terminal block for the TEMP SENSOR. Connect the terminal labeled TMP on the zone sensor to the terminal labeled TEMP on the Zone Controller terminal block for the TEMP SENSOR. If the zone sensor has a setpoint adjust slider, then connect the sensor terminal labeled AUX to the Zone Controller AUX terminal block labeled AUX1. TIP If sensors must be installed on walls which are solid and cannot be penetrated, surface mounted boxes and raceway can be purchased from your local electrical distributor ROOM SENSOR WITH OVERRIDE AND AJUSTABLE SETPOINT TB TMP Normal OVR Warmer Cooler AUX ADJUSTABLE SETPOINT ZONE CONTROLLER AUX VS AUX1 AUX2 OVERRRIDE TEMP T'STAT FIGURE 9: ZONE SENSOR WIRING Installation Instruction - Meridian Basic 11

12 SUPPLY AIR TEMPERATURE SENSOR The supply air temperature sensor should be located as close to the rooftop unit discharge as possible for best response and mounted upstream of the bypass damper for best results. Locate the sensor in the center of the widest part of the duct. Use the supplied template and a 5/16" drill to make a hole for the sensor. Install the gasket over the probe and mount securely to the duct using the supplied sheet metal screws. Be sure the gasket is compressed to provide an air tight seal. For best accuracy, apply insulation on the outside of the duct, over the sensor. This will help prevent thermal gradients from affecting the sensor. RETURN AIR TEMPERATURE SENSOR The return air temperature sensor should be located as close to the rooftop unit return air intake as possible. Avoid locations which will be exposed to extreme outside temperatures. Locate the sensor in the center of the widest part of the duct. Use the supplied template and a 5/16" drill to make a hole for the sensor. Install the gasket over the probe and mount securely to the duct using the supplied sheet metal screws. Be sure the gasket is compressed to provide an air tight seal. OUTSIDE AIR TEMPERATURE SENSOR The outside air sensor must be located where it will not be affected by direct sun or heat producing equipment. Mounting under the eve of a roof is often a good choice. Complaints of inaccurate outside sensor readings are very common and can almost always be shown to be the result of poor sensor location. NOTE All temperature sensors supplied with the system utilize the same thermistor type sensing element. Refer to Appendix Table 1, TEMPERATURE SENSOR RESISTANCE CHART, for troubleshooting sensor problems. STATIC PRESSURE SENSOR The static pressure sensor is designed to be mounted near the controller, or on the ductwork near the pickup tube, and connected to the controller via its modular plug. If the sensor is mounted on the ductwork, away from the controller, the modular plug must be cut off and 3-conductor wire spliced onto the sensor leads. The controller has a terminal block which is paralleled with the modular jack to allow connection when this method is utilized. Do not mount the return air sensor in the mixed air section. This will cause an error in the reading. For best accuracy, apply insulation on the outside of the duct, over the sensor. This will help prevent thermal gradients from affecting the sensor. Mount the static pressure sensor on a vertical surface with the tube tips pointing downward. Avoid any kinks or sharp bends in the tubing which runs from the pickup tube to the sensor. The plastic housing on the sensor is electrically conductive. Avoid contact with any electrical components. It is acceptable to mount the sensor on grounded sheet metal such as ductwork, electrical panels, etc. 12 Installation Instruction - Meridian Basic

13 . Use extreme care when mounting the sensor to avoid damage to the plastic housing. Do not over tighten the mounting screws! Do not use mounting screws which are too large for the holes! TIP Having at least feet of tubing between the pick-uptubeandthepressuresensorwillimprove control performance by acting as a filter to remove pressure fluctuations caused by turbulence in the duct. AUXILIARY RELAY BOARD FOR ZONE CONTROLLERS An optional auxiliary relay board is available for the Zone Controllers. This board provides additional outputs for the following applications: Parallel Fan Box Heat Auxiliary Heat (typically perimeter type) Series Fan The board comes shipped with a modular cable which plugs directly into the Zone Controller connector marked Expansion. After connecting the board, the system will need to be powered OFF then ON for the system to recognize the presence of the relay board. NOTE Refer to Appendix Table 2 for instructions concerning proper location of the static pressure sensor. FIGURE 11: AUXILIARY RELAY BOARD LAYOUT FIGURE 10: STATIC PRESSURE SENSOR WIRING Relay contacts are rated for pilot duty only! Do not apply voltages higher than. Installation Instruction - Meridian Basic 13

14 ZONE CONTROLLER AUXILIARY RELAY BOARD OPERATION Relay #1 - Parallel Fan If the zone is in cooling mode or vent mode, theparallel fan canactivateanytimethezonetemperaturedrops0.5 F below the heating setpoint. It de-activates when the temperature rises 0.5 F above the heating setpoint. Relay #2 - Box Heat If the zone is in cooling mode or vent mode the box heat can activate anytime the zone temperature drops 1.5 F belowthe heating setpoint. It de-activates when the temperature rises to within 1.0 F of the heating setpoint. Box heat is not allowed to activate in the heating mode when there is hot air being supplied by the air handler. This output was intended to allow zone re-heat while the Zone Manager is satisfying cooling demands in other zones. Relay #3 - Aux Heat In the occupied mode, theaux heat canactivateanytime the zone temperature is 0.5 F below the aux heat setpoint. It de-activates when the temperature rises 0.5 F abovethe aux heat setpoint. In the unoccupied mode, the aux heat uses the unoccupied heating setpoint with the same deadband values mentioned above. This prevents the zone from maintaining the same aux heat setpoint at night that it does during the daytime. This output was intended to allow zone heating, to augment thenormalheatingmodeandalsotoallowazonetoattempt to satisfy its own heating needs before creating a heating demand at the Zone Manager. Relay#4-SeriesFan The series fan runs anytime the main fan is running. This includes occupied and unoccupied modes. In the unoccupied mode, the fan can only start when the zone damper is closed. The controller checks to be sure the damper is closed before starting the fan. LINK INTERFACE An optional CommLink Interface is available for the Meridian Basic system to provide on site computer hook-up or modem interface for remote communications. The Commlink is wired as shown below.locate the CommLink near the computer or modem. The cable connections between the CommLink and the computer or model should be kept to less than 25 feet. The CommLink comes complete with computer and modem cables, and a plug-in power supply. FIGURE 12: LINK INTERFACE WIRING 14 Installation Instruction - Meridian Basic

15 APPENDIX Table 1: Temperature Resistance Chart Table 1: Temperature Resistance Chart TEMPERATURE F RESISTANCE Ω* VOLTAGE AT INPUT* TEMPERATURE F RESISTANCE Ω* VOLTAGE AT INPUT* , , , , , , , , , , , , , , , , , , , , , , , , , , , , , *Notes: 76 10, , , , , , , , , , , , , , , , , , , , Use the resistance column to check the thermistor sensor while disconnected from the controllers (not powered). 2. Use the voltage column to check sensors while connected to powered controllers. Read voltage with meter setondcvolts.placethe"-"(minus)leadonterminal and the "" (plus) lead on the sensor input terminal being investigated. If the voltage is above 5.08 VDC, then the sensor or wiring is "open". If the voltage is less than 0.05 VDC, the sensor or wiring is shorted. Installation Instruction - Meridian Basic 15

16 Table 2: Static Pressure Location Information Preferred Location If the trunk ducts are properly sized for minimum pressure drop, the location of the static pickup probe is not particularly critical. It should ideally be located at right angles to the airflow in a straight section of the supply duct approximately 2/3 the distance of the total length of the supply duct. Also the probe should be located not less than 3 duct diameters downstream and 2 duct diameters upstream of any elbow or takeoff. SUPPLY TEMP SENSOR FAN BYPASS RETURN AIR SENSOR RETURN STATIC PRESSURE PICKUP 3D MIN. 2D MIN. Less Than Ideal, But Acceptable Since the "ideal" location is often difficult to find in an installation, a location in the main trunk where the tip is not in a "negative pressure area" (e.g. just downstream of the inside curveofanelbow)oranareawherethetubeopeningis directly impacted by the velocity of the supply air. Least Desirable, But Acceptable If the supply duct comes directly from the unit and immediately splits in opposite directions, the pressure pickup should be located ahead of the split, or as close to it as possible, even if the bypass damper(s) are located downstream of the split. TO ZONES TEE PICKUP PRESSURE STATIC G S SENSING LINES ARE EQUAL SENSOR TEMP SUPPLY BYPASS TO ZONES RETURN FAN Subject to change without notice. Printed in U.S.A. Copyright by Unitary Products Group All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product York OK Group Drive 73069

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MERIDIAN PLUS CONTENTS TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...3 ZONE MANAGER ADDRESSING.................. 5 COMMUNICATIONSLOOPS...6 COMMUNICATIONS LOOP WIRING

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit

More information

TMS Series MP46x Flex Probes* Installation Instructions

TMS Series MP46x Flex Probes* Installation Instructions PNEUMERCATOR Liquid Level Control Systems TMS Series MP46x Flex Probes* Installation Instructions Model MP461, MP462 And MP463 Magnetostrictive Flex Probes Installation For: MODEL TMS2000 and MODEL TMS3000

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting

More information

Form: Rev. A (0802) Supersedes: Nothing. Zoning Tec. echnical Guide

Form: Rev. A (0802) Supersedes: Nothing. Zoning Tec. echnical Guide Form: 036-478-00 Rev. A (080) Supersedes: Nothing Control ol Systems Zoning ec echnical Guide able Of Contents Zone Zone How Meridian Works... 5 Why Should I Use Meridian?... 6 What Is Unique About Meridian?...

More information

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan

More information

OE326-23I-OR VAV/Zone Controller

OE326-23I-OR VAV/Zone Controller + 4 8 - Description The OE36-3I-OR is a that is designed for pressure independent VAV Box and Zone Damper applications. It is supplied with an integral Airflow Sensor and is mounted in a plastic enclosure.

More information

NJK Precision Product NJK-02 Sensor Installation Guide

NJK Precision Product NJK-02 Sensor Installation Guide Precision -02 Sensor 2017 Product Line Precision Product Table of Contents Precision Company Overview - Page 2-02 Installation Guidelines - Page 3-02 Recommended Installations - Page 5-02 Non-Recommended

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

YCCS TE-6800 Series Temperature Sensors

YCCS TE-6800 Series Temperature Sensors YCCS TE-6800 Series Temperature Sensors TE-68xx-xNN0S Installation Instructions 85-YIM-B-070 Applications The York Commercial Comfort System (YCCS) TE-68xx-xNN0S Series Temperature Sensors provide temperature

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

Installation Instructions

Installation Instructions CRPWREXH08A0, CRPWREXH09A0, CRPWREXH08A00, CRPWREXH08A00 For Use With Horizontal EconoMi$er IV, EconoMi$er, or EconoMi$er X (W70) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... PACKAGE

More information

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012 COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER

More information

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series) Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant

More information

Installation Instructions

Installation Instructions 08A0, 09A0, 08A00, 08A00 For Use With Horizontal EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY HORIZONTAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor Product Identification and Overview Power and Communication on Just Two Wires Available with Temperature Sensing, Temperature Setpoint, Optional Occupant Override, Optional Display and Optional %RH Sensing

More information

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51) Engineering Bulletin IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51) Issued By: Clarksville Marketing and Sales Support Order No. UN-PRB001-EN

More information

MicroTech II Applied Rooftop Unit Controller

MicroTech II Applied Rooftop Unit Controller ( Installation and Maintenance IM-696 Group: Applied Systems Part Number: IM696 Date: April 21 MicroTech II Applied Rooftop Unit Controller Used with McQuay models: RPS, RFS, RCS, RDT, RPR, RFR, RDS, RAR

More information

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING The Model RPC30 (-LON) Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause

More information

MicroTech II Applied Rooftop Unit Controller

MicroTech II Applied Rooftop Unit Controller Installation and Maintenance IM-696-2 Group: Applied Systems Part Number: IM696 Date: March 2004 MicroTech II Applied Rooftop Unit Controller Used with McQuay models: RPS, RFS, RCS, RDT, RPR, RFR, RPE,

More information

General Information... 2

General Information... 2 VAV Flow Controller-Actuators CSP 5001/5002 Applications Guide General Information... 2 CSP 5001/5002 Overview...2 Controller, Sensor, and Thermostat Functions...3 Wiring...4 Air Flow Sensor Connection...4

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual The IAQ50 Air Damper/Monitor Installation and Maintenance Manual RUSKIN MANUFACTURING 3900 Dr. Greaves Road Kansas City, Missouri 64030-1183 U.S.A. ! WARNING DO NOT TAMPER WITH (REMOVE, REPLACE, RELOCATE

More information

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE 100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up

More information

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

MicroTech Applied Rooftop Unit Controller

MicroTech Applied Rooftop Unit Controller Installation & Maintenance Manual IM 483-6 Group: Applied Systems Part Number: 571477Y-02 Date: December 1996 MicroTech Applied Rooftop Unit Controller Used with McQuay models: RPS, RFS, RCS, RDT, RDS

More information

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas Installation Manual IOM-MBC-00 08-30-04 Mixing Box Control Systems Installation,, and Maintenance Manual Contents Page Introduction...1 General...1 Safety...1 Inspection...1 Mixing Box Control Systems...2

More information

ECONOMIZERS. 5/2012 Supersedes

ECONOMIZERS. 5/2012 Supersedes Litho U.S.A. 2012 ECONOMIZERS 507031 01 5/2012 Supersedes 506747 01 K1ECON ECONOMIZERS INSTALLATION INSTRUCTIONS FOR ECONOMIZERS AND OUTDOOR AIR HOODS USED WITH KG/KC/KH 024, 030, 036, 048, 060, 072, 090

More information

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation Hoffman Controls Installation & Operating Instructions General 1. This instruction is a guide for connecting and operating the 200-3 Series Flow Controller with the 207 Series Thermostat and the 241-2

More information

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

LF24-ECON-R03(-R10) US Operation, Installation and Wiring LF24-ECON-R03(-R0) US Operation, Installation and Wiring Operation LF24-ECON-R03(-R0) US The LF24-ECON-R03(-R0) US provides a direct coupling solution for RoofTop Unit(RTU) economizer dampers. Control

More information

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

Gen INSTALLATION MANUAL

Gen INSTALLATION MANUAL Gen 2 INSTALLATION MANUAL READ THIS FIRST Installation of this system should be carried out by qualified persons familiar with the general installation of law enforcement electronics commonly installed

More information

TC62D Installation Instructions

TC62D Installation Instructions TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port.

More information

Installation, Service, and Troubleshooting Instructions

Installation, Service, and Troubleshooting Instructions Installation, Service, and Troubleshooting Instructions Page GENERAL........................................ 2 INSTALLATION................................. 2-4 Zone Controller Placement.......................

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN February 2004 CNT-SVN02B-EN Tracer AH541

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

SLIMZONE CLASSIC /

SLIMZONE CLASSIC / SLIMZONE CLASSIC 2701-001 / 2701-006 ZONE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 IMPORTANT NOTE...1 1.2 FEATURES...1 1.3 SAFETY INSTRUCTIONS...1 2. APPLICATION

More information

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT Supersedes Form145.10-IOM1 (810) Form 145.10-IOM1 (910) LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A AIR CONDITIONING UNITS INSTALLATION INSTRUCTIONS IMPORTANT!

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions Product Identification Fig 1. BAPI-Com Communication Output Module Fig 2. BAPI-Com Room Sensor, BA/BS4SCOM Operations Overview The BAPI-Com sensor is designed to be used in retrofit applications on just

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

EZ Zone COMMERCIAL BUILDING ZONE CONTROLS

EZ Zone COMMERCIAL BUILDING ZONE CONTROLS (596) 035-09313 EZ Zone COMMERCIAL BUILDING ZONE CONTROLS SINGLE PACKAGE AIR CONDITIONERS, HEAT PUMPS & SPLIT-SYSTEM AIR CONDITIONERS INTRODUCTION Using constant volume unitary equipment to heat and cool

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

Torque min. 35 in-lb, for control of air dampers

Torque min. 35 in-lb, for control of air dampers LF-SR (-S) US Proportional Damper Actuator, Spring Return Fail-Safe, V for to VDC, or to ma Control Signal. Output Signal of to VDC for Position Indication. Torque min. 35 in-lb, for control of air dampers

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

Installation, Start-Up and Configuration Instructions

Installation, Start-Up and Configuration Instructions 3V Control System VVT Zone Controller Pressure Dependent Control Installation, Start-Up and Configuration Instructions Part Number 33ZCVVTZC-01 CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...2 INSTALLATION...

More information

MP461SC Flex Probes* Installation Instructions

MP461SC Flex Probes* Installation Instructions PNEUMERCATOR Liquid Level Control Systems MP461SC Flex Probes* Installation Instructions Model MP461SC Magnetostrictive Flex Probes For use with the following consoles: TMS2000 TMS3000 NOTE: MP461SC PROBES

More information

MINI-MASTERZONE ZONING SYSTEM. MMP2 For Plug-In Damper Motors. Installation and Operating Instructions. 2 Zones. Controlling Your Comfort Room by Room

MINI-MASTERZONE ZONING SYSTEM. MMP2 For Plug-In Damper Motors. Installation and Operating Instructions. 2 Zones. Controlling Your Comfort Room by Room MINI-MASTEZONE ZONING SYSTEM MMP2 For Plug-In Damper Motors 2 Zones Installation and Operating Instructions ontrolling Your omfort oom by oom MINI-MASTEZONE ZONING SYSTEM MMP2 Features System Mode Indicator

More information

Installation Instructions

Installation Instructions H068A00 H069A00 H070A00 POWER EXHAUST ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 12.5to25TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 INSTALLATION... 2 Power Exhaust

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

TRAC-3 TENSION READOUT AND CONTROL

TRAC-3 TENSION READOUT AND CONTROL Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL TRAC-3 READOUT AND CONTROL For Control of Magnetic Particle

More information

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE FORM 040.202 REV 106 WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE Models: ADJ-W Wireless Wall Adjuster Compatible with all Type HC, CW and C Therma-Fuser Diffusers CONTENTS ORDERING...

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Metasys Zoning Package Overview

Metasys Zoning Package Overview Technical Bulletin Issue Date August 26, 2002 Metasys Zoning Package Overview Metasys Zoning Package Overview...2 Introduction... 2 Key Concepts... 3 Related Information... 3 Metasys Zoning Package Components...

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Thermistor Temperature Sensor Range

Thermistor Temperature Sensor Range smart Main Features ontrols Temperature Sensors for all common applications Data Sheet S1 Temperature Sensors with Thermistor Elements Close tolerance Thermistor Elements (+/- 0.2 accuracy within range

More information

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - PV POWERED from 0 V to VDC with smart power management at very low PV power levels, A must, for soft FAN start & smooth controller operation - Microprocessor

More information

VOC Duct and Rough Service Sensor

VOC Duct and Rough Service Sensor Overview and Identification Humans respirate Volatile Organic Compounds (VOCs) as well as CO 2. The BAPI sensor measures these VOCs and indicates space occupancy just as well as a CO 2 sensor. The advantage

More information

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath

More information

SEN and SEN Outdoor Air Temperature Sensors

SEN and SEN Outdoor Air Temperature Sensors FANs 216, 1628.3 Product/Technical Bulletin SEN-500-2, SEN-500-3 Issue Date 0996 SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors The SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors offer

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Venturi FX VFX Series v100 Issue Date: 11/22/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety Precautions... 1 Caution to Contractors...1

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2100/2200 FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER MODEL 2100: Constant face velocity, variable volume MODEL 2200: Constant face velocity, variable volume

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

TS , -850 Series TS , -850 Series TS-57031, TS

TS , -850 Series TS , -850 Series TS-57031, TS TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature

More information

Compact Low Pressure Sensor

Compact Low Pressure Sensor Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

INFINITY ZONING QUICK START GUIDE

INFINITY ZONING QUICK START GUIDE Infinity Zoning Quick Start Page 1 of 7 INFINITY ZONING QUICK START GUIDE INTRODUCTION Infinity Zoning incorporates cutting edge technology that sets it apart from any other zoning system on the market

More information

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT COMPONENT LIST The Model T-59 Space Temperature Sensor with Override & Setpoint Adjustment consists of the following

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) 3/4 Centered (Field Selectable) NF24-SR (-S) US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for 2 to 1 VDC, or 4 to ma Control Signal. Output Signal of 2 to 1 VDC for Position Indication Torque min. 6 in-lb, for control

More information