1 Precision -02 Sensor 2017 Product Line Precision Product Table of Contents Precision Company Overview - Page 2-02 Installation Guidelines - Page 3-02 Recommended Installations - Page 5-02 Non-Recommended Installations - Page 7-02 Installation Solutions (Outside Air) - Page 9-02 Installation Solutions (Mixed Air)- Page Installation Solutions (Supply Air) - Page Wiring - Page 21 Page 1

2 -02 Sensor Purchasing Guide Precision Company Overview The Precision Product Overview: The -02 Air Flow Measuring Station is proudly Made in the USA in our Factory located in Eaton Rapids, Michigan. The -02 Air Flow Measuring Station consists of the perimeter sampling aluminum extrusion Flow Frame, a Sensing Module which contains the sensing probe and signal transmitter and is mounted to the Flow Frame and is the one single sensing probe associated with each -02 Air Flow Measuring Station, and a Display Module with User Interface for set up and calibration of each flow station. The Precision Team: Kevin Hein, President Von Weise Companies (kevin.hein@vonweise.com) Nick Wolgamott, Vice President of Engineering PMAS-MAF and Precision Michael Hurd, Factory Representative Precision (michael.hurd@vonweise.com) Robert Pierce, Plant Manager and Design Von Weise Companies Beth Allen, Sales Manager Von Weise Companies (beth.allen@vonweise.com) Page 2

3 -02 - Location and Mounting: Installation Guidelines. All -02 Air Flow Measuring Station installations should be verified by an Sales Representative or Factory Representative as to system effect on the air flow sensor and air flow sensor effect on the air system. System Effects must always be considered when installing an Air Flow Measuring Station to assure that the air flow measured through the Sensor is a true representation of the desired air flow and is not being effected by other air sources such as return air flows or by system dynamics that adversely effect the air flow through the Sensor. System Effects must also be considered to assure that the installation of the Sensor does not create any negative impact on the dynamics of the air system such as stratification, excessive flow restrictions, or low temperature detector (freeze stat) operations. It will be the responsibility of the Sales Representative or direct Ordering Customer to assure that the air flow measured through the Sensor is a true representation of the desired air flow and is not being effected by other air sources such as return air flows or by system dynamics that adversely effect the air flow through the Sensor. It will also be the responsibility of the Sales Representative or direct Ordering Customer to assure that the installation of the Sensor does not create any negative impact on the dynamics of the air system such as stratification, excessive flow restrictions, or low temperature detector (freeze stat) operations. Air Flow Sensor Accuracy is often enhanced by straight, even runs of ductwork that help smooth out air flows and signal noise. The Sensor will perform accurately in these ideal settings. We anticipate that our product may be installed in less than ideal placements such as limited straight duct lengths or ductless (plenums or rain hood) installations. There are some installation situations that should be avoided. Although some customers have found ways to make the Sensor operate effectively in applications that Precision suggests to avoid, Precision will not warrant accuracy or repeatability when the Sensor is installed outside of recommended installation practices. Page 3

4 -02 - Location and Mounting: Installation Guidelines. Do Not install Sensors downstream of damper banks: Place all sensors ahead of damper banks. This will keep the sensor out of mixing chambers and will eliminate poor sensor readings due to damper restrictions and possible return air entrainment. Whenever the Sensor is mounted inside of a mixing air chamber there may be air flow issues caused by internal system effects and air flow dynamics. Do Not install Sensors in an outside air louver section where the Sensor is hanging freely in the OA chamber as this can allow air to swirl on the outlet side of the sensor and may cause a false reading through the Sensor. Do Not install Sensors for branch duct flow measurement directly on a main ducted plenum as the air that will flow in the plenum will inherently create a negative swirling effect at the branch transition and will cause a false reading through the Sensor. If the Sensor is to be mounted in a branch duct off from a main supply plenum have a transitional duct boot installed ahead of the Sensor or move the Sensor further downstream in the branch ductwork to avoid the turbulent flow at the plenum to branch transition. Do Not install Sensors on the face of a Coil or Filter Bank as the coil or filters will become loaded with dirt and debris and will cause a false reading through the Sensor. Do Not install Sensor Modules external to the Flow Frame on the bottom of the Flow Frame as this can allow water to build up inside of the Sensor Module and effect sensor accuracy. This is most often an issue with outside air applications. Do Not install Sensors directly downstream of turning vanes as they can divert air from the perimeter of the ductwork and create an unreliable flow signal through the Sensor. Do Not install Sensors in a supply plenum with a large (or multiple) Centrifugal Fans feeding the air into a supply plenum. That air is distributed unevenly throughout the supply plenum and can also have strong cross flows of air across the face any of the supply duct take offs. Do Not install Sensors in a supply plenum with a large Centrifugal Fan feeding air into the supply plenum tapered bellmouth as the air will turbulent at best. The tapered section of ductwork can allow supplied air to be forced through the center of the duct and bypassing some of the sampled air from the -02 Perimeter Sampling Flow Frame. Page 4

5 -02 - Location and Mounting: Recommended Installations. In the applications above the -02 Air Flow Sensor can be installed with little or no ductwork leading into or out of the -02 Air Flow Sensor. In a supply plenum with Plug or Plenum Centrifugal Fans the air is distributed evenly throughout the entire supply plenum. In this application the -02 Air Flow Sensor can be installed with little or no ductwork leading into the sensor. Page 5

6 -02 - Location and Mounting: Recommended Installations. In the application above the -02 Air Flow Sensor can be installed with little or no ductwork leading into or out of the -02 Air Flow Sensor. In the application below the -02 Air Flow Sensor can be installed in the floor grating or ceiling take off directly with little or no ductwork leading into or out of the -02 Air Flow Sensor. Page 6

7 -02 - Location and Mounting: Non-Recommended Installations! Avoid mounting sensors into any widened duct or any other application where measured air could be forced through the center of the sensor and not accurately sampled. Avoid mounting sensors on the face of any filter banks or coil banks. These items can become filled with debris and force more air through the outside of the unit and through the sensor causing a false raised flow reading when the actual flow has been decreased. Avoid mounting the sensor on the downstream side of a damper set whenever possible. If you do have to install an sensor on the downstream side of the dampers ensure that it is only done with opposed blade dampers to avoid excessive concentrations of air flow in one area of the sensor. No matter what the conditions, once you introduce the sensor into, or near the mixing chamber, you will assume all dynamics and responsibilities of that mixing chamber (air mixing, entrainment, false readings, freeze stat issues). Page 7

8 -02 - Location and Mounting: Non-Recommended Installations! Do Not install Sensors directly downstream of turning vanes as they can divert air from the perimeter of the ductwork and create an unreliable flow signal through the Sensor. Do Not install Sensors for branch duct flow measurement directly on a main supply plenum as the air that will flow in the plenum will inherently create a negative swirling effect at the branch transition and will cause a false reading through the Sensor. If the Sensor is to be mounted in a branch duct off from a main supply plenum have a transitional duct boot installed ahead of the Sensor or move the Sensor further downstream in the branch ductwork to avoid the turbulent flow at the plenum to branch transition. Page 8 Do Not install Sensors in an outside air louver section where the Sensor is hanging freely in the OA chamber as this can allow air to swirl on the outlet side of the sensor and may cause a false reading through the Sensor. (See Page #10)

9 -02 - Location and Mounting: Installation Solutions Installation #2 (Non-Recommended) Installation #1 (Recommended) -02 sensor without angle flange. Add a 1 inch, 90 degree angle flange around face of -02 air flow sensor. In an open air installation (such as an outside air or open plenum) feeding inlet application the Sensor will need to have a 1 inch sheet metal angle bracket installed on the leading edge of the sensor Flow Frame. This will serve as a velocity stack and will help prevent entering air from circling around the sensor inlet and potentially being missed in the sampling process. The sheet metal angle flange can be flush with the face of the Flow Frame or can extend slightly outward. The operation of the Sensor without the angle bracket will still be functional but the signal will be very unstable and difficult to settle down. Strong cross flows can essentially blow by the inlet ports of the Flow Frame. Page 9

10 -02 - Location and Mounting: Installation Solutions Installation #2 (Non-Recommended) Installation #1 (Recommended) Outside Air Chamber Exterior Wall Outside Air Chamber Exterior Wall Block Wall Sensor Air Flow Block Wall Sensor Air Flow Eddy Currents Air Flow Exterior Wall Air Flow Exterior Wall Outside Air Dampers Outside Air Dampers In the mounting installation above the Sensor Flow Frame is to be mounted in an exterior wall inlet directly after the inlet rain louvers. Installation #1 allows for air to enter and exit the sensor with smooth flow and dependable flow readings. Installation #2 has the exiting side of the Sensor Flow Frame suspended into the outdoor air chamber and can have the ability to allow reverse eddy currents on the leaving edge of the Sensor. This may give an altered air flow reading and can be avoided by placing the Sensor more centered on the exterior wall opening. In the mounting installation to the right the Sensor Flow Frame is to be mounted in an exterior wall inlet directly above the outside air dampers. An Sensor mounted just below exterior wall opening can allow outside air to pass the leading edge of the sensor frame. Mounting the sensor frame closer to the exterior wall edge will force most of the air through one edge of the sensor frame. Moving the Sensor Flow Frame closer to the dampers will allow better flow through the entire sensor. Air Flow Sensor Outside Air Dampers Exterior Wall Air Flow Page 10

11 -02 - Location and Mounting: Installation Solutions Installation #2 (Non-Recommended) In this mounting installation the Sensor Flow Frame is mounted in an area where the air flow will be very strong on one area of the opening with a high air velocity and the air flow will be very minimal or non-existent on the opposite side of the Flow Frame. If the Sensor Module is mounted on the low velocity side of the Flow Frame where air velocities can be less than 25% (see #1 Below) of the average air velocity across the flow frame there is a risk that sampled air can be drawn from the Sensor Module and cause the Sensor to read a lower than actual air flow. This can become an issue whether the air flow is being supplied or returned. Sensor Module / Probe Extremely Low Air Velocity Extremely High Air Velocity Installation #1 (Recommended) Sensor Module / Probe Extremely Low Air Velocity To resolve this locate the Sensor Module on the Higher air velocity side of the Sensor Flow Frame to allow the sensing probe to accurately measure the sampled air from the flow frame. Extremely High Air Velocity #1 - A 25% air velocity minimum or greater will allow for an open consideration when locating the Sensor Module. System Effects must be considered when locating the Sensor Module. Any installation where placement of the module is in an area with an air flow velocity below 25% of the average velocity can not be guaranteed for accuracy and signal dependability. Page 11

12 -02 - Location and Mounting: Installation Solutions Installation (Problem) Installation (Solution) Outside Air Inlet Hoods are often located in close proximity to the relief or exhaust dampers on many rooftop and packaged units. Caution must be utilized when installing sensors in these areas to ensure that the addition of an Sensor mounted on the end of an outside air intake does not allow the sensor to protrude into the exhaust air stream causing an unwanted system entrainment effect. Mount the Sensor inside of a rain hood or outside air inlet opening to assure that the factory system dynamics of the rooftop or packaged unit are not altered Page 12

13 -02 - Location and Mounting: Installation Solutions Problem: In a Mixed Air Plenum the return air can be forced back into the outside air duct if the total air system is out of balance or out of sequence. This condition will create an errant reading with the outside air sensor. In this situation the -02 Air Flow Sensor will read reverse air flow as regular flow. Solution: The air handling system must be in complete balance and under optimal control conditions to assure that return air is not being forced backwards through the outside air ductwork and flow sensor. Problem: In a Mixed Air Plenum the return air can be forced back into the outside air duct when the HVAC system is in a full recirculating mode if the outside air dampers do not completely close off. This condition will create a flow reading through the outside air sensor when the outside air flow is believed to zero. In this situation the -02 Air Flow Sensor will read reverse air flow as regular flow. Solution: The air handler outside air dampers must be adjusted so that they close off completely. Page 13

14 -02 - Location and Mounting: Installation Solutions Installation (Problem) Installation (Solution) Return Air Outside Air Mixed Air Sensor installed on outside air Return air collides with Flow Sheet metal added to direct return air Problem: In a Retrofit application the return air can be forced back into the outside air duct due to a lack of available space in an existing mechanical room. This condition will create an errant reading with the outside air sensor. In this situation the -02 Air Flow Sensor will read reverse air flow as regular flow. Solution: Sheet metal diverting plates may need to be engineered to assure that return air is not being forced backwards through the outside air ductwork and flow sensor. Page 14

15 -02 - Location and Mounting: Installation Solutions Installation #2 (Problem) Installation #1 (Solution) Minimum of 4 Duct Diameters In a supply plenum with a large Centrifugal Fan feeding air into the supply plenum tapered bellmouth the air will be turbulent. The tapered section of ductwork can allow supplied air to be forced through the center of the duct bypassing some of the sampled air from the -02 Perimeter Sampling Flow Frame. In this application the -02 Air Flow Sensor can NOT be installed without some lengths (Minimum 4 duct diameters) of straight ductwork leading into the sensor and the -02 will need to be installed further downstream in that straight duct length. This installation will have a very unstable flow reading through the -02 air flow sensor as the flow off from each blade of the centrifugal fan will have an impact on the sensor reading. Page 15

16 -02 - Location and Mounting: Installation Solutions Minimum of 4 Duct Diameters Minimum of 4 Duct Diameters Minimum of 4 Duct Diameters Locate Sensor as far downstream as possible (Minimum of 4 duct diameters) to avoid air turbulence and entrainment. Solution: Locate Sensor as far downstream as possible (Minimum of 4 duct diameters) to avoid air turbulence and entrainment. Solution: Problem: In a supply plenum with a large (or multiple) Centrifugal Fans feeding the air into the supply plenum that air is distributed unevenly throughout the supply plenum and can also have strong cross flows of air across the face any of the supply duct take offs. In this application the -02 Air Flow Sensor can NOT be installed without ductwork leading into the sensor and the -02 will need to be installed further downstream in each of the individual duct runs. Page 16

17 -02 - Location and Mounting: Installation Solutions Minimum 4 Duct Diameters Minimum 4 Duct Diameters Installation (Problem) Locate Sensor as far downstream as possible (Minimum of 4 duct diameters) to avoid air turbulence and entrainment. Installation (Solution) Locate Sensor as far downstream as possible (Minimum of 4 duct diameters) to avoid air turbulence and entrainment. Installation (Solution) In a supply plenum with a Supply Fan feeding air at a right angle into the supply plenum the air will be turbulent as it changes flow direction. In this application the -02 Air Flow Sensor can NOT be installed without some lengths of straight ductwork leading into the sensor and the -02 will need to be installed further downstream in the straight duct lengths. Page 17

18 -02 - Location and Mounting: Installation Solutions Minimum 4 Duct Diameters In -Line Supply or Return Fan Minimum 4 Duct Diameters Installation (Solution) Locate Sensor as far downstream from fan as possible (Minimum of 4 duct diameters) to avoid air turbulence. Installation (Solution) Locate Sensor as far upstream from fan as possible (Minimum of 4 duct diameters) to avoid air turbulence. Do not place Sensors in close proximity to any fan system. In-Line Fans of any type will have a pulsating air flow signal based on the air delivered by each blade. In the above application the -02 Air Flow Sensor can NOT be installed without some lengths of straight ductwork leading into the sensor and the -02 will need to be installed further downstream or upstream in the straight duct lengths. This installation will have a very unstable flow reading through the -02 air flow sensor as the flow off from each blade of the fan will have an impact on the sensor reading. Page 18

19 -02 - Location and Mounting: Installation Solutions Problem: Sensors mounted directly adjacent to plenum airflow and are affected by air directional changes that are turbulent causing a swirling effect at the inlet of the sensor frame which will offer a poor air flow reading. AFMS AFMS AFMS Air Flow Solution: install sensors downstream on the inlet of the VAV Box. This will allow the Sensors to accurately read flow at the VAV Box and will be out of the turbulent air at the branch duct connections to the main plenum. VAV Box VAV Box AFMS VAV Box AFMS AFMS Air Flow Page 19

20 -02 - Location and Mounting: Installation Solutions Problem: Outside air minimum and maximum dampers located in a shared plenum can allow minimum air flow to pass through maximum air flow sensor when maximum dampers are closed causing a false reading through the maximum air sensor Solution: Install sheet metal extension sleeves on both the minimum and maximum outside damper inlets to direct the air into the proper sensor and to eliminate false readings through sensors on unopened dampers. Page 20

21 -02 Wiring and Electrical The Display/Operator Interface will receive 24 VDC power from the control electrician. Sensor Probe and Transmitter will be powered from the Display/Operator Interface. Building Automation wiring and 24 VDC wiring will be done via a termination block in the Display/Operator Interface only. Optional 24 VAC Wiring (see below). Sensor Power Requirements: All wiring to Sensor shall be a 4-wire. 24 VDC power/common and 0 to 10 VDC signal/common. Direct Current Wiring (24 VDC): Sensors powered from the same 24 VDC power source as the Building Automation System control field panel should operate without any issues with either the electrical or the BAS signal. Optional Wiring: (Alternating Current Wiring-24 VAC): An Isolated Transformer(s) will be required to power the 24 VAC power for the Sensors if either of the following situations are true. -02 Display Display / Operator Interface 4-3/4 If the Sensors will be powered by a 24 VAC power system that has any part of the power transformer or system externally earth grounded to a building electric casing or panel buss bar or field panel. Or, if the Sensors will be powered from a different transformer source than the building automation system /4 Termination block located behind Display/O.I. Cover External Wiring Sensor RJ-45 Page 21

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5 -02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4

More information

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5 -02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4

More information

Introducing NJK Precision Airflow Measuring Stations

Introducing NJK Precision Airflow Measuring Stations Introducing Precision Airflow Measuring Stations A new and unique airflow measuring station that accurately measures airflows at very low flow rates and can operate in physically restrictive applications

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting

More information

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual COMPANY Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:SANITARYMAN16 Mechanical Specifications Measuring Accuracy ± 1.0%

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

APPLYING VSO OPTION TO SOLUTION AIR HANDLING UNITS

APPLYING VSO OPTION TO SOLUTION AIR HANDLING UNITS APPLYING VSO OPTION TO SOLUTION AIR HANDLING UNITS APPLICATION GUIDE Supersedes: Nothing Form: 102.20-AG14 (207) GENERAL YORKWORKS VSO OPTION The VSO (Variable Size Openings) option is now available in

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

Silver Series Thermal Dispersion Airflow Measurement Technology

Silver Series Thermal Dispersion Airflow Measurement Technology Thermal Dispersion Airflow Measurement Model STx104-U Unit Ventilator Airflow Measurement System Technical Data Silver Series Thermal Dispersion Airflow Measurement Technology APPLICATIONS Direct outdoor

More information

MODEL 1100 TURBINE FLOW METER

MODEL 1100 TURBINE FLOW METER MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment VORTAB FLOW CONDITIONERS For Flow Meters, Pumps and Other Flow Profile Critical Equipment Reduce flow meter straight-run requirements into just a few diameters Balance pump inlet flow to eliminate premature

More information

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes Stainless Steel Pitot Airflow Traverse Probes The VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probe is ideally suited for new installations or retrofit applications requiring accurate airflow

More information

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual The IAQ50 Air Damper/Monitor Installation and Maintenance Manual RUSKIN MANUFACTURING 3900 Dr. Greaves Road Kansas City, Missouri 64030-1183 U.S.A. ! WARNING DO NOT TAMPER WITH (REMOVE, REPLACE, RELOCATE

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:TRQSMAN16 Table of Contents Contents Table of Contents... 2

More information

SILENCER SELECTION INSTRUCTIONS

SILENCER SELECTION INSTRUCTIONS For general information in HVAC Acoustics, consult the following publications: 2013 ASHRAE Fundamentals Handbook, Chapter 8 Sound and Vibration 2011 ASHRAE Applications Handbook, Chapter 48 Noise and Vibration

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -CH and Vektor -CD Centrifugal High Plume and High Plume Dilution Exhaust System July 2015 Vektor-CH High Plume and Vektor-CD High Plume Dilution Exhaust System Greenheck

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Variable Air Volume (VAV) Pressure Independent Control

Variable Air Volume (VAV) Pressure Independent Control VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned

More information

Gold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1

Gold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1 Thermal Dispersion Airflow Measurement Model GF1 Technical Manual Gold Series Thermal Dispersion Airflow Measurement Technology Advantage Gold Series by Ebtron Installation, Operation and Maintenance Technical

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station Accutrol, LLC Product Sheet VTS Series US Patents 6,991,177 & 7,543,759 Digital Airflow Measurement Station Innovative features of the AccuStation VTS Series! Digital Airflow Sensing Modular Design Intuitive

More information

SILENCER SELECTION INSTRUCTIONS

SILENCER SELECTION INSTRUCTIONS SILENCER SELECTION INSTRUCTIONS For general information in HVAC Acoustics, consult the following publications: > > 07 ASHRAE Fundamentals Handbook, Chapter 8 Sound and Vibration > > 05 ASHRAE Applications

More information

Element D Services Heating Ventilating and Air Conditioning ODG010107

Element D Services Heating Ventilating and Air Conditioning ODG010107 Element D Services Heating Ventilating and Air Conditioning ODG010107 D304203 Vivarium Exhaust and Ventilation System Part 1. General 1. This section supplements Design Guideline Element D3042 on exhaust

More information

STR Circular VAV Terminal Units

STR Circular VAV Terminal Units STR Circular VAV ASLI Circular Variable Air Volume (STR) Terminal s are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of

More information

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1 HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MERIDIAN PLUS CONTENTS TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...3 ZONE MANAGER ADDRESSING.................. 5 COMMUNICATIONSLOOPS...6 COMMUNICATIONS LOOP WIRING

More information

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination. Quoted as per your request: two (2) Non-Pressurized, Drive-Thru, Full Down Draft, Paint Booth model: TDD-16-16-20-DT with interior working dimensions of 16-0 wide X 16-0 tall X 20-0 long. Overall dimensions

More information

2.6. Air Flow Control Valve Type PRD

2.6. Air Flow Control Valve Type PRD 2.6. Air Flow Control Valve Type PRD Page 1/10 Air Flow Control Valve, Type PRD Page 2/10 Air Flow Control Valve Type PRD Description and Design The PRD remains the air valve of choice for critical heating,

More information

AD-1251 Probe with Differential Pressure Transducer

AD-1251 Probe with Differential Pressure Transducer AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)

More information

Products for Indoor Air Quality and Control

Products for Indoor Air Quality and Control Products for Indoor Air Quality and Control Constant Volume Fan Powered Units AC_J Series ECM Motor Technical Guide Page 1 Table of Contents General Information Page Number ECM Motor Introduction 3 Design

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

Air Flow Measurement Technologies

Air Flow Measurement Technologies Page 1/7 Typical Air Flow Measurement Applications Air Flow Control True Flow Feedback Theory of Vortex Shedding Air Flow Measurement Pitot Air Flow Measurement Thermal Air Flow Measurement Advantages

More information

Model 1100 Turbine Flow Meter

Model 1100 Turbine Flow Meter Model 1100 Turbine Flow Meter INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 www.hedland.com TABLE

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

FXV/CXV & FXV3/CXV3 Layout Guidelines

FXV/CXV & FXV3/CXV3 Layout Guidelines FXV/CXV & FXV3/CXV3 Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS 4080 SE International Way. Suite B110, Milwaukie, OR 97222 (503) 654-0867 Fax: (503) 654-4671 email: ftech@filtertechnologyltd.com www.filtertechnologyltd.com DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE)

More information

PIM Pressure Independence Module

PIM Pressure Independence Module PIM Pressure Independence Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independence Module is a modulating static pressure controller/actuator that allows

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS amca CERTIFIED RATInGS VOLU-probe Pitot Airflow Traverse Probes FLOW MEASUREMENT STATION PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Accurate airflow measurement for demanding applications

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

NOW INTEGRATED WITH MLM DESIGNED FOR VAV DIFFUSER SYSTEMS LINEAR CHARACTERISTICS NO REGULAR MAINTENANCE REQUIRED PRESSURE SENSOR AND CONTROLLERS

NOW INTEGRATED WITH MLM DESIGNED FOR VAV DIFFUSER SYSTEMS LINEAR CHARACTERISTICS NO REGULAR MAINTENANCE REQUIRED PRESSURE SENSOR AND CONTROLLERS PRESSURE CONTROL DAMPER 20 PCD NOW INTEGRATED WITH MLM DESIGNED FOR VAV DIFFUSER SYSTEMS LINEAR CHARACTERISTICS LOW NOISE ELECTRIC ACTUATION NO REGULAR MAINTENANCE REQUIRED PRESSURE SENSOR AND CONTROLLERS

More information

VAV TERMINAL UNITS. VVD VAV Diffusers

VAV TERMINAL UNITS. VVD VAV Diffusers Introduction ASLI VAV diffusers, VVD are variable air volume diffuser for supply air in variable air volume system. In many conventional HVAC systems, multiple work spaces are controlled by a single thermostat.

More information

Halton Rex 600 RE6 - Adaptable active chilled beam

Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE

More information

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4) MOEL COE UCT SHAPE = Round = Rectangular = Flat Oval PROBE MATERIAL = Aluminum/ABS = CPVC & ABS = 0SS = High Temp SS (50 F / C Max) PROBE QUANTITY = = s = s = s SENSORS PER PROBE = Sensor per = Sensors

More information

MODEL 900 IMPELLER-TYPE FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

RETROFIT TERMINAL UNITS

RETROFIT TERMINAL UNITS GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

C7046A,B,C,D Air Temperature Sensors

C7046A,B,C,D Air Temperature Sensors C7046A,B,C,D Air Temperature Sensors FEATURES PRODUCT DATA APPLICATION The C7046 series of Air Temperature Sensors function as primary and/or secondary sensors in electronic control systems. C7046A,C Sensors

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -MH and Vektor -MD Mixed Flow High Plume and High Plume Dilution Blower August 2013 Vektor-MH High Plume and High Plume Dilution Blower Greenheck s Vektor-MH high plume

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Demand Based Static Pressure Reset Control for Laboratories

Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC Product Sheet Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC 21 Commerce Drive, Danbury, CT 06810 203-445-9991 www.accutrolllc.com Contents and specifications are

More information

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value. E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

Installation Instructions

Installation Instructions 010A00 011A00 014A00 SMALL ROOFTOP UNITS TWO POSITION OUTDOOR AIR DAMPER 2to15TONS (50/60 Hz) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE... 1 SAFETY CONSIDERATIONS...

More information

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82 E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev. Installation Guide DigiTract 4 Two Stage Heat/Cool Comfort Control System Part #DT4MAN Rev. October 2013 Zoning Systems That s all we do. TABLE OF CONTENTS...Page INTRODUCTION...1 SYSTEM DESCRIPTION...1

More information

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories. Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated

More information

Development of Power-head Based Fan Airflow Station

Development of Power-head Based Fan Airflow Station ESL-IC-5-1- Development of Power-head Based Fan Airflow Station Gang ang Research associate University of Nebraska, Lincoln Mingsheng Liu Professor University of Nebraska, Lincoln Abstract Fan airflow

More information

SLIMZONE CLASSIC /

SLIMZONE CLASSIC / SLIMZONE CLASSIC 2701-001 / 2701-006 ZONE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 IMPORTANT NOTE...1 1.2 FEATURES...1 1.3 SAFETY INSTRUCTIONS...1 2. APPLICATION

More information

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc. BULLETIN 13.01-01 August 2009 PERMASEAL ISO 9001:2008 Certified QMS SMG Valves A Unit of Southern Manufacturing Group, Inc. Design and Construction Permaseal Plug Valves are designed for on-off and diverting

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

Laboratory Exhaust Air Terminal

Laboratory Exhaust Air Terminal Laboratory Exhaust Air Terminal Page 1 of 11 Figure 1. Laboratory Exhaust Air Terminal. The APOGEE Automation Laboratory Room Exhaust Air Terminal is an industrial grade, easy-to-install, prepackaged airflow

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

Laboratory Room Controller

Laboratory Room Controller Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space

More information

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate

More information

INFINITY ZONING QUICK START GUIDE

INFINITY ZONING QUICK START GUIDE Infinity Zoning Quick Start Page 1 of 7 INFINITY ZONING QUICK START GUIDE INTRODUCTION Infinity Zoning incorporates cutting edge technology that sets it apart from any other zoning system on the market

More information

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE 100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

FAN PERFORMANCE MODULATION

FAN PERFORMANCE MODULATION FAN PERFORMANCE MODULATION Some fan systems have changing air requirement during operation, such as variable air volume systems, while others have changing pressure requirements; both airflow and pressure

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Document Number 463384 VCD, FBH & FBV MODELS Vertical and Horizontal Mount Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance.

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

VXI Closed circuit cooling towers

VXI Closed circuit cooling towers Closed circuit cooling towers Key benefits Reliable Quiet Compact characteristics Counter flow, centrifugal fan, forced draft Capacity range up to 2615 kw Maximum entering fluid temperature 82 C Typical

More information

Metasys Zoning Package Overview

Metasys Zoning Package Overview Technical Bulletin Issue Date August 26, 2002 Metasys Zoning Package Overview Metasys Zoning Package Overview...2 Introduction... 2 Key Concepts... 3 Related Information... 3 Metasys Zoning Package Components...

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric

More information

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers Cab Air Quality Systems Filter Options: HEPA-level (EU P3) MERV 16

More information