INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter
|
|
- Norah French
- 6 years ago
- Views:
Transcription
1
2 INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free operation where units will be installed above ceilings and hallways and in closets; compact spacesaving design to allow more valuable living space; and the quiet performance affordable by a centrally-located unit that is ducted to individual rooms. lthough primarily intended for apartment markets, these versatile units can also be used in low static pressure applications where ducted units are needed. UNIT NOMENCLTURE The model number denotes the following characteristics of the unit : CP 06 F C - 4 L - F DUCTED CONCELED WITH PLENUM F - c/w Filter SIZE Nominal ir Flow () GENERTION F F Series VOLTGE CODE 0~40V-Ph-50/60Hz CONNECTION LH : Left Hand RH : Right Hand ROWS OF 3 : Three Rows 4 : Four Rows 6 : Six Rows FIN TYPE : luminium H : Hydrophillic C : Copper Những điều kỳ lạ ng DESIGN PRMETER VOLTGE CODE UNIT POWER MINIMUM VOLTGE MXIMUM VOLTGE C 0~40V-Ph-50/60Hz 0 40
3 INTRODUCTION BSIC UNIT ND CBINET The basic unit is fabricated out of galvanized steel. The return plenum, fan deck and the top of the coil section shall be lined with 6mm coated Polyethylene Foam. Fan motor(s) are easily removable for serviceability with a terminal box with terminal strip fitted for wiring. Filter media is G as a standard and for units with plenum, filters can be conveniently removed from either the side or the back. The CDCP series cooling coil is made of corrugated aluminum fins which are mechanically bonded to the copper tubes. The fins have a maximum fin spacing of.mm in between to prevent any moisture carry over and to provide the sufficient cooling capacity without compromising the right airflow. Coils shall be factory leak tested at 350psig (400kPa) and suitable for working pressure up to 50psig (700kPa). DRIVE PCKGE CDCP series motors are specified to have 3 speed permanently split capacitor. Motors have permanently lubricated ball bearings and class B insulation. Standard motor provided are IP0 rated. The fan(s) are centrifugal forward curved type fan which are statically and dynamically balanced. DRIN PN Electro-Galvanized (EG) drain pans for the CDCP are oven-baked polyester powder coated with its external surface insulated with 5mm PE foam (fire class rated). OPTIONL FETURES iết! Hydrophilic or Copper fin coil 3 rows / 4 rows cooling coil + row heating coil Thermostat Electrical Fin Heater FILTER Spare set filter Return Grille (Double) Nominal " l-mesh G Filter Nominal " washable G3 Filter CSING Stainless steel casing Double insulation (0mm insulation) Extended drain pan Powder coating casing SS Drain Pan SS Extended Drain Pan Supply Grille (Double) Double skin PU panel (7mm / 5mm / 50mm)
4 INTRODUCTION BSIC UNIT ND CBINET The basic unit is fabricated out of galvanized steel. The return plenum, fan deck and the top of the coil section shall be lined with 6mm coated Polyethylene Foam. Fan motor(s) are easily removable for serviceability with a terminal box with terminal strip fitted for wiring. Filter media is G as a standard and for units with plenum, filters can be conveniently removed from either the side or the back. The CDCP series cooling coil is made of corrugated aluminum fins which are mechanically bonded to the copper tubes. The fins have a maximum fin spacing of.mm in between to prevent any moisture carry over and to provide the sufficient cooling capacity without compromising the right airflow. Coils shall be factory leak tested at 350psig (400kPa) and suitable for working pressure up to 50psig (700kPa). DRIVE PCKGE CDCP series motors are specified to have 3 speed permanently split capacitor. Motors have permanently lubricated ball bearings and class B insulation. Standard motor provided are IP0 rated. The fan(s) are centrifugal forward curved type fan which are statically and dynamically balanced. DRIN PN Electro-Galvanized (EG) drain pans for the CDCP are oven-baked polyester powder coated with its external surface insulated with 5mm PE foam (fire class rated). OPTIONL FETURES Hydrophilic or Copper fin coil 3 rows / 4 rows cooling coil + row heating coil Thermostat Electrical Fin Heater FILTER Spare set filter Return Grille (Double) Nominal " l-mesh G Filter Nominal " washable G3 Filter CSING Stainless steel casing Double insulation (0mm insulation) Extended drain pan Powder coating casing SS Drain Pan SS Extended Drain Pan Supply Grille (Double) Double skin PU panel (7mm / 5mm / 50mm)
5 PHYSICL DT DCP-F Physical Data 3 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (00) Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8 " O.D (76) 0.9 (7) 0.34 (84) 0.9 (73) 0. (56) 0. (54) 50 (700) 350 (400) 7/8" O.D. - /8" O.D. Copper Pipe (56) 3-Speed Permanent Split Capacitor Motor 0-40 / / Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7 () DD9x9 () DD9x9 () DD9x7 () DD9x7 () DD9x9 () DD9x9 () DD9x9 () 3*0 340*50 9. (738) *5 340* (8) Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating - /4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340*565 3*5 340* (968) (098) (8) (348) (478) *6 340* (578) 73 NOTES Cooling Capacity irflow :- The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 3
6 PHYSICL DT DCP-F Physical Data 4 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (99) (84) 35.3 Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8" O.D (80) 0.34 () 0.9 (73) 0.5 (6) 0.5 (6) 50 (700) 350 (400) - /8" O.D. Copper Pipe 3-Speed Permanent Split Capacitor Motor / / (6) 50 Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7 () DD9x9 () DD9x9 () DD9x7 () DD9x7 () DD9x9 () DD9x9 () DD9x9 () 3*0 340*50 9. (738) 37 3*5 340* (8) 43 6 Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating -/4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340* (968) (098) (8) (348) 70 3*5 340* (478) *6 340* (578) 79 NOTES Cooling Capacity irflow :- The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 4
7 PHYSICL DT DCP-F Physical Data 6 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (8) 35.3 Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8" O.D (78) 0.9 (73) 0.8 (69) 0.4 (60) 0. (54) 0.3 (58) 50 (700) 350 (400) - /8" O.D. - 3/8" O.D. Copper Pipe Speed Permanent Split Capacitor Motor / / (54) 50 Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7() DD9x9() DD9x9() DD9x7() DD9x7() DD9x9() DD9x9() DD9x9() 3*0 340*50 9. (738) 39 3*5 340* (8) 44 6 Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating -/4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340* (968) (098) (8) (348) 75 3*5 340* (478) 8.5 3*6 340* (578) 83 NOTES Cooling Capacity irflow : - The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 5
8 SHOPFLOOR DIMENSIONS DCP 06 0FC Shopfloor (Single Skin) B 3 H G I 375 J 0 7 CONNECTION LOCTION SLOTS ø*. (6) C D TOP VIEW E SIDE VIEW 70 F FRONT VIEW 7
9 SHOPFLOOR DIMENSIONS DCP 0FC Shopfloor (Single Skin) B 3 H G I 375 J 0 7 CONNECTION LOCTION SLOTS ø*. (6) C D TOP VIEW E F SIDE VIEW FRONT VIEW CONNECTION DIMENSIONS B C D E F ROW CHW. In/Outlet G H I J DCP 06FC DCP 06-0FC DCP -0FC 3 3/4" BSPT " BSPT DCP 08FC DCP 0FC DCP 06-0FC DCP 06-0FC DCP -0FC 4 6 " BSPT -/4" BSPT DCP FC DCP 4FC DCP 6FC DCP 8FC DCP 0FC
10 Double Skin 7MMDS 5MMDS 50MMDS DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP 0 DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP 0 DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP B C D E F G H I J K L M DIMENSIONS IN MM SHOPFLOOR DIMENSIONS 0
11 * While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore please confirm with your local distribution office for the latest update on the product interested. ll rights reserved.
DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS
DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationCHILLED WATER DUCTED FAN COIL
SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.
More informationLOW STATIC FAN COIL UNITS District Cooling Chilled Water Application
STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications
More informationCommercial Blower Coil Air Handlers
Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationFan Coil Units POWERED BY KLIMAK ITALY
Fan Coil Units POWERED BY KLIMAK ITALY Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationCHILLED WATER FAN-COIL UNITS
40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in
More informationTechnical Sales Guide # 040 YDFC 0 1 Page 2
17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationGuide Specifications. General. Casing. Coil/Drain pan. Fan/Motor
Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationGENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS
GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4
More information42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application
42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code
More informationAddress: VTS Clima L.L.C.
Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS
More informationDAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)
Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationSPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11
AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal
More informationHIGH STATIC FAN COIL UNITS
STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More information42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001
42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More information42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM
42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More information42HS Fan Coil Unit (High Static Pressure)
42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationFCVC Series VERTICAL FAN COILS
VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,
More informationBUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC
BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationCeiling Concealed Chilled Water Fan Coil Unit
Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...
More informationHigh Static Fan Coil Units YDFC
Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationChassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A
Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationProduct Data. 42D Ducted Fan Coil Air Conditioners cfm
Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationWE MAKE INDOOR AIR BETTER
WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationNomenclature. Contents. Air Handling Unit SR AH 250 LP HS
SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal
More informationHorizontal Fan Coils 200-1,200 CFM
Horizontal Fan Coils 200-1,200 CFM Table of Contents Williams Fan Coils & Air Handlers..................................................... 1 Horizontal Models......................................................................
More informationCB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A
E N G I N E E R I N G D T I R H N D L E R S CB29M Multi Position 60 HZ Bulletin No. 210478 November 2008 Supersedes July 2007 3 to 5 Tons Optional Electric Heat 5 to 30 kw MODEL NUMBER IDENTIFICTION CB
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More informationCUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION
UH Series abinet Unit Heaters TM HEAT TRANSFER DIVISION UH SERIES ABINET UNIT HEATERS ROUGHING IN DIMENSIONS TYPIAL ARRANGEMENTS B B 1 1/" (38) REESSING FRAME B 1 1/" (38) REESSING FRAME FULLY EXPOSED
More informationDESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS
DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil
More informationHi-Performance Series Fan Coil Technical Catalog
Hi-Performance Series Fan Coil Technical Catalog HYB Horizontal Hideaway Furred-in with galvanized finish for ducted/high static applications in drop-ceilings or over-closets. (600-2000 CFM) HGC Horizontal
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationPrepared By : Checked By : Approved By : Page 1 out of 6
Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)
-P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air
More informationContents. Carrier China
42CE Fan Coil Unit Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration solutions, with operations
More informationGENERAL ELECTRIC FAN COIL UNITS
GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data
More information39L Series. Central Station Air Handlers. Nominal: 2,000-17,750 CFM. World's No.1 Air Conditioning Expert
39L Series Central Station ir Handlers Nominal: 2,000-17,750 CFM World's No.1 ir Conditioning Expert www.carrier.co.th 39L Series Compact, fully-assembled airhandlers combine versatility with economical,
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationFan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4
Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical
More informationELTAFANTECH Air Handling Unit 700 up to 42,000 CFM
an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.
More informationAIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements
AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationPCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A
PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered
More informationCEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS
CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationLow Profile Unit Cooler
Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -
More informationCHP20R Basic Unit CHP
ENGINEERING DT PCKGED HET PUMPS CHP20R ELITE SERIES RESIDENTIL 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 24,000 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 24,200 to 56,000 (7.1 to 16.4
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationEngineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h
Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationHigh Performance Fan Coils FCHG Genesis Series Horizontal
Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationCBH17-95V Horizontal Unit CB V
E N G I N E E R I N G D T I R H N D L E R S CB17/CBH17 UP FLOW/HORIZONTL 60 HZ Bulletin No. 210070 July 2008 Supersedes May 2002 CBH17-95V Horizontal Unit CB17-95V Up-Flow Unit Nominal Capacity 7.5 to
More informationBVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS
BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,
More informationProduct Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz
18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design
More information