INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

Size: px
Start display at page:

Download "INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter"

Transcription

1

2 INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free operation where units will be installed above ceilings and hallways and in closets; compact spacesaving design to allow more valuable living space; and the quiet performance affordable by a centrally-located unit that is ducted to individual rooms. lthough primarily intended for apartment markets, these versatile units can also be used in low static pressure applications where ducted units are needed. UNIT NOMENCLTURE The model number denotes the following characteristics of the unit : CP 06 F C - 4 L - F DUCTED CONCELED WITH PLENUM F - c/w Filter SIZE Nominal ir Flow () GENERTION F F Series VOLTGE CODE 0~40V-Ph-50/60Hz CONNECTION LH : Left Hand RH : Right Hand ROWS OF 3 : Three Rows 4 : Four Rows 6 : Six Rows FIN TYPE : luminium H : Hydrophillic C : Copper Những điều kỳ lạ ng DESIGN PRMETER VOLTGE CODE UNIT POWER MINIMUM VOLTGE MXIMUM VOLTGE C 0~40V-Ph-50/60Hz 0 40

3 INTRODUCTION BSIC UNIT ND CBINET The basic unit is fabricated out of galvanized steel. The return plenum, fan deck and the top of the coil section shall be lined with 6mm coated Polyethylene Foam. Fan motor(s) are easily removable for serviceability with a terminal box with terminal strip fitted for wiring. Filter media is G as a standard and for units with plenum, filters can be conveniently removed from either the side or the back. The CDCP series cooling coil is made of corrugated aluminum fins which are mechanically bonded to the copper tubes. The fins have a maximum fin spacing of.mm in between to prevent any moisture carry over and to provide the sufficient cooling capacity without compromising the right airflow. Coils shall be factory leak tested at 350psig (400kPa) and suitable for working pressure up to 50psig (700kPa). DRIVE PCKGE CDCP series motors are specified to have 3 speed permanently split capacitor. Motors have permanently lubricated ball bearings and class B insulation. Standard motor provided are IP0 rated. The fan(s) are centrifugal forward curved type fan which are statically and dynamically balanced. DRIN PN Electro-Galvanized (EG) drain pans for the CDCP are oven-baked polyester powder coated with its external surface insulated with 5mm PE foam (fire class rated). OPTIONL FETURES iết! Hydrophilic or Copper fin coil 3 rows / 4 rows cooling coil + row heating coil Thermostat Electrical Fin Heater FILTER Spare set filter Return Grille (Double) Nominal " l-mesh G Filter Nominal " washable G3 Filter CSING Stainless steel casing Double insulation (0mm insulation) Extended drain pan Powder coating casing SS Drain Pan SS Extended Drain Pan Supply Grille (Double) Double skin PU panel (7mm / 5mm / 50mm)

4 INTRODUCTION BSIC UNIT ND CBINET The basic unit is fabricated out of galvanized steel. The return plenum, fan deck and the top of the coil section shall be lined with 6mm coated Polyethylene Foam. Fan motor(s) are easily removable for serviceability with a terminal box with terminal strip fitted for wiring. Filter media is G as a standard and for units with plenum, filters can be conveniently removed from either the side or the back. The CDCP series cooling coil is made of corrugated aluminum fins which are mechanically bonded to the copper tubes. The fins have a maximum fin spacing of.mm in between to prevent any moisture carry over and to provide the sufficient cooling capacity without compromising the right airflow. Coils shall be factory leak tested at 350psig (400kPa) and suitable for working pressure up to 50psig (700kPa). DRIVE PCKGE CDCP series motors are specified to have 3 speed permanently split capacitor. Motors have permanently lubricated ball bearings and class B insulation. Standard motor provided are IP0 rated. The fan(s) are centrifugal forward curved type fan which are statically and dynamically balanced. DRIN PN Electro-Galvanized (EG) drain pans for the CDCP are oven-baked polyester powder coated with its external surface insulated with 5mm PE foam (fire class rated). OPTIONL FETURES Hydrophilic or Copper fin coil 3 rows / 4 rows cooling coil + row heating coil Thermostat Electrical Fin Heater FILTER Spare set filter Return Grille (Double) Nominal " l-mesh G Filter Nominal " washable G3 Filter CSING Stainless steel casing Double insulation (0mm insulation) Extended drain pan Powder coating casing SS Drain Pan SS Extended Drain Pan Supply Grille (Double) Double skin PU panel (7mm / 5mm / 50mm)

5 PHYSICL DT DCP-F Physical Data 3 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (00) Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8 " O.D (76) 0.9 (7) 0.34 (84) 0.9 (73) 0. (56) 0. (54) 50 (700) 350 (400) 7/8" O.D. - /8" O.D. Copper Pipe (56) 3-Speed Permanent Split Capacitor Motor 0-40 / / Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7 () DD9x9 () DD9x9 () DD9x7 () DD9x7 () DD9x9 () DD9x9 () DD9x9 () 3*0 340*50 9. (738) *5 340* (8) Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating - /4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340*565 3*5 340* (968) (098) (8) (348) (478) *6 340* (578) 73 NOTES Cooling Capacity irflow :- The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 3

6 PHYSICL DT DCP-F Physical Data 4 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (99) (84) 35.3 Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8" O.D (80) 0.34 () 0.9 (73) 0.5 (6) 0.5 (6) 50 (700) 350 (400) - /8" O.D. Copper Pipe 3-Speed Permanent Split Capacitor Motor / / (6) 50 Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7 () DD9x9 () DD9x9 () DD9x7 () DD9x7 () DD9x9 () DD9x9 () DD9x9 () 3*0 340*50 9. (738) 37 3*5 340* (8) 43 6 Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating -/4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340* (968) (098) (8) (348) 70 3*5 340* (478) *6 340* (578) 79 NOTES Cooling Capacity irflow :- The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 4

7 PHYSICL DT DCP-F Physical Data 6 Row Coil Nominal irflow Total Cooling Capacity Water Flow Rate Water Pressure Drop Tube Thickness / Fin Thickness Number of Rows / FPI Tube Size Face rea Coil Static Resistance Max. Working Pressure Testing Pressure Connection (Copper Tube) Header MOTOR Power Supply Number of Motor Rating Output (per unit motor) Max. Running mp (40V/Ph/50Hz) (per unit motor) Poles FN / Drive Blower Size (Qty) FRME Casing Insulation DRIN PN Material Finishing Connection FILTER Filter Qty / Unit Nominal Size (per unit filter) ctual Size (per unit filter) OVERLL DIMENSION Depth Width Height Estimated Unit Weight High Medium Low ton MBH kwr USgpm l/s ft.wg kpa mm / mm ft² m² in.wg (Pa) V / Ph / Hz Qty Watt in mm kg (8) 35.3 Seamless Copper Tube / Corrugated luminium Fin 0.30 / / 3/8" O.D (78) 0.9 (73) 0.8 (69) 0.4 (60) 0. (54) 0.3 (58) 50 (700) 350 (400) - /8" O.D. - 3/8" O.D. Copper Pipe Speed Permanent Split Capacitor Motor / / (54) 50 Centrifugal Fan (Forward-Curved Steel Fan Wheels) / Direct Motor Driven DD9x7() DD9x9() DD9x9() DD9x7() DD9x7() DD9x9() DD9x9() DD9x9() 3*0 340*50 9. (738) 39 3*5 340* (8) 44 6 Galvanized Steel Polyethylene Foam : 6mm Electro-Galvanized Steel Epoxy Polyester Powder Coating -/4" O.D. Steel Pipe Non Threaded Nominal " Washable Filter (75~80% rrestance) 3*9 340*750 3*35 340*880 3*0 340*505 3* 340* (968) (098) (8) (348) 75 3*5 340* (478) 8.5 3*6 340* (578) 83 NOTES Cooling Capacity irflow : - The performances are based on the following conditions: : - Entering air temperature = 80ºF (6.7ºC) DB, 67ºF (9.4ºC) WB - Entering chilled water temperature = 44ºF (6.7ºC) - Leaving chilled water temperature = 54ºF (.ºC) : - Medium fan speed - 40V-Ph-50Hz power supply - Under dry coil condition at 0.in.WG (50Pa) external static pressure - Unit with filter(s) 5

8 SHOPFLOOR DIMENSIONS DCP 06 0FC Shopfloor (Single Skin) B 3 H G I 375 J 0 7 CONNECTION LOCTION SLOTS ø*. (6) C D TOP VIEW E SIDE VIEW 70 F FRONT VIEW 7

9 SHOPFLOOR DIMENSIONS DCP 0FC Shopfloor (Single Skin) B 3 H G I 375 J 0 7 CONNECTION LOCTION SLOTS ø*. (6) C D TOP VIEW E F SIDE VIEW FRONT VIEW CONNECTION DIMENSIONS B C D E F ROW CHW. In/Outlet G H I J DCP 06FC DCP 06-0FC DCP -0FC 3 3/4" BSPT " BSPT DCP 08FC DCP 0FC DCP 06-0FC DCP 06-0FC DCP -0FC 4 6 " BSPT -/4" BSPT DCP FC DCP 4FC DCP 6FC DCP 8FC DCP 0FC

10 Double Skin 7MMDS 5MMDS 50MMDS DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP 0 DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP 0 DCP 06 DCP 08 DCP 0 DCP DCP 4 DCP 6 DCP 8 DCP B C D E F G H I J K L M DIMENSIONS IN MM SHOPFLOOR DIMENSIONS 0

11 * While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore please confirm with your local distribution office for the latest update on the product interested. ll rights reserved.

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

CHILLED WATER DUCTED FAN COIL

CHILLED WATER DUCTED FAN COIL SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

Fan Coil Units POWERED BY KLIMAK ITALY

Fan Coil Units POWERED BY KLIMAK ITALY Fan Coil Units POWERED BY KLIMAK ITALY Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11 AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal

More information

HIGH STATIC FAN COIL UNITS

HIGH STATIC FAN COIL UNITS STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001 42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

42HS Fan Coil Unit (High Static Pressure)

42HS Fan Coil Unit (High Static Pressure) 42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

High Static Fan Coil Units YDFC

High Static Fan Coil Units YDFC Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s) NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

WE MAKE INDOOR AIR BETTER

WE MAKE INDOOR AIR BETTER WE MAKE INDOOR AIR BETTER Water-Cooled Heat Pumps & Air Conditioners /4-Ton to 60-Tons Various voltages/phases Suitable for duct connections Ideal for use with free air supply plenum (2-axis adjustable

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal

More information

Horizontal Fan Coils 200-1,200 CFM

Horizontal Fan Coils 200-1,200 CFM Horizontal Fan Coils 200-1,200 CFM Table of Contents Williams Fan Coils & Air Handlers..................................................... 1 Horizontal Models......................................................................

More information

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A E N G I N E E R I N G D T I R H N D L E R S CB29M Multi Position 60 HZ Bulletin No. 210478 November 2008 Supersedes July 2007 3 to 5 Tons Optional Electric Heat 5 to 30 kw MODEL NUMBER IDENTIFICTION CB

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION UH Series abinet Unit Heaters TM HEAT TRANSFER DIVISION UH SERIES ABINET UNIT HEATERS ROUGHING IN DIMENSIONS TYPIAL ARRANGEMENTS B B 1 1/" (38) REESSING FRAME B 1 1/" (38) REESSING FRAME FULLY EXPOSED

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

Hi-Performance Series Fan Coil Technical Catalog

Hi-Performance Series Fan Coil Technical Catalog Hi-Performance Series Fan Coil Technical Catalog HYB Horizontal Hideaway Furred-in with galvanized finish for ducted/high static applications in drop-ceilings or over-closets. (600-2000 CFM) HGC Horizontal

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

Contents. Carrier China

Contents. Carrier China 42CE Fan Coil Unit Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration solutions, with operations

More information

GENERAL ELECTRIC FAN COIL UNITS

GENERAL ELECTRIC FAN COIL UNITS GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data

More information

39L Series. Central Station Air Handlers. Nominal: 2,000-17,750 CFM. World's No.1 Air Conditioning Expert

39L Series. Central Station Air Handlers. Nominal: 2,000-17,750 CFM. World's No.1 Air Conditioning Expert 39L Series Central Station ir Handlers Nominal: 2,000-17,750 CFM World's No.1 ir Conditioning Expert www.carrier.co.th 39L Series Compact, fully-assembled airhandlers combine versatility with economical,

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4 Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical

More information

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.

More information

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered

More information

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -

More information

CHP20R Basic Unit CHP

CHP20R Basic Unit CHP ENGINEERING DT PCKGED HET PUMPS CHP20R ELITE SERIES RESIDENTIL 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 24,000 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 24,200 to 56,000 (7.1 to 16.4

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

CBH17-95V Horizontal Unit CB V

CBH17-95V Horizontal Unit CB V E N G I N E E R I N G D T I R H N D L E R S CB17/CBH17 UP FLOW/HORIZONTL 60 HZ Bulletin No. 210070 July 2008 Supersedes May 2002 CBH17-95V Horizontal Unit CB17-95V Up-Flow Unit Nominal Capacity 7.5 to

More information

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information