Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation
|
|
- Rosa Daniels
- 5 years ago
- Views:
Transcription
1 ir Flow Factors Model: TDC irflow Measurements Procedure 1. Record diffuser velocities with lnor probe in the locations and orientation shown the velocity Measurement Location Chart. Note: Each diagram within the Velocity Measurement Location chart contains ' 'signs, measure the velocity at these points on the specific TDC. 2. Calculate airflow each side using the following equation. Flow Rate: CFM = verage Velocity x rea Factor x alancing Factor. Example: Size 12 x 36 diffuser, 3-1 pattern; with velocity readings 1000, 1200, 1250, 1300, 1250, 1200, and 1000 fpm. verage velocity = 1171 fpm. Flow factor table information is as follows. rea Factor Side = 0.08 rea Factor Side = 0.46 alancing Factor = Calculations: irflow Side = 1171 x 0.08 x = 109 CFM irflow Side = 1171 x 0.46 x = 629 CFM Total irflow = = 1367 CFM Note: 3-1 denotes a three-way pattern in one diffuser. Refer to the Velocity Measurement Locations chart. lnor Model 6070, 6000, 2220, or Probe Orientation Contents Page irflow Measurement Procedure 1 Velocity Measurement Location 2 One-way Factors 3 Two-way Factors 4 Two-way Corner Factors 6 Three-way Factors 7 Four-way Factors 9 Round dapter Factors 10
2 ir Flow Factors Velocity Measurement Locations lnor Velometer alancing S way 2 S2 2 2-way E2 F2 G2 2-way Corner 3 (3-1) E3 (3-2) 3 3-way way Note: Each diffuser diagram within the Velocity Measurement Location chart contains ' 'signs, position the probe at each point to measure the velocity on each specific TDC.
3 One-way Factors One-way Factors The following tables provide the area and balancing factors based on flow pattern. Use the corresponding area pattern and balancing tables based on the measurement locations chart on page 2. rea Patterns - 1, 1, and S1 Length alancing Factors - 1 and S1 Length alancing Factors - 1 Length
4 Two-way Factors Two-way Factors The following tables provide the area and balancing factors based on flow pattern. Use the corresponding area pattern and balancing tables based on the measurement locations chart on page 2. rea Patterns - 2, 2, and S2 Length alancing Factors - 2 Length alancing Factors - 2 Length
5 Two-Way Factors Two-way Factors (continued) alancing Factors - S2 Length
6 Two-way Corner Factors Two-way Corner Factors The following tables provide the area and balancing factors based on flow pattern. Use the corresponding area pattern and balancing tables based on the measurement locations chart on the previous page. rea Patterns - E2 and F2 Side - Length Side - Length rea Pattern - G2 Length alancing Factors - E2, F2, and G2 Length
7 Three-Way Factors Three-Way Factors The following tables provide the area and balancing factors based on flow pattern. Use the corresponding area pattern and balancing tables based on the measurement locations chart on page 2. rea Patterns - 3, 3-2, 3, and E rea Pattern Side - Length alancing Factors - 3 and 3-1 Length Side - Length Side - Length Side - Length
8 Three-way Factors Three-way Factors (continued) alancing Factors Length alancing Factors - 3 and E3 Length
9 Four-Way Factors Four-Way Factors The following tables provide the area and balancing factors based on flow pattern. Use the corresponding area pattern and balancing tables based on the measurement locations chart on page 2. rea Patterns - 4 and 4 Side - Length Side - Length alancing Factors - 4 and 4 Length
10 Round dapter Factors TDC with Round dapters rea Factors Pattern rea 6 x 6 9 x 9 12 x x x 18 S S G (a) (b) alancing Factors Pattern 6-inch 8-inch 10-inch 12-inch 14-inch 16-inch S S G
Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.
Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination
More informationDonn. Air Diffuser. Technical Data. plenum. diffuser frame. Features
Technical Data Donn Features The DONN brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser, which is placed on the 2 x 2, narrow-suspension
More informationSPD/SPDV SPD SPDV. High Velocity/High Aspiration Air Outlet. Construction
SPD/SPDV SPD O D-1/8 C Saturn Plaque Diffuser US Patent B H SPDV SPD Dimensions in Inches MODEL A B C D H O SPD-04 7-1/2 2 1-1/4 4 3-3/4 5-1/8 SPD-06 10 2 1-3/16 6 4 7-1/2 SPD-08 12 2 1-3/16 8 4 9-1/2
More informationDONN Brand Air Diffuser
Technical Data DONN Brand Air Diffuser Features The DONN Brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser which is placed on the 2
More informationB1-2. Table of Contents LOUVERED FACE DIFFUSERS
Table of Contents 2, FR,, M & M feature a round neck and four cones. & feature a round neck, four cones, and adjustable pattern controllers.,, M, & M feature a round neck and three cones. & feature a round
More informationASHRAE 110 Test Report Cover Sheet
SHRE 110 Test Report over Sheet lient: mgen orporation One mgen center rive Thousand Oaks 91320-3424 Ray Russell Test Report # : 1 Test ate # : 1/6/2005 Lead Technician: Joe Tech Test Report Scope and
More informationRPD ROUND PLAQUE DIFFUSER
ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.
More informationfor Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D
for Pleasant & Healthy Air-Distribution ISO 90012000 Product Bulletin 135-D Linear Bar & Floor Grilles Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION DASCO Linear Bar
More informationFE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT
Technical Data Sheet FE-1000 INSERTION TYPE IR SENSING ELEMENT DESCRIPTION The FE-1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing
More information* Acoustical Tile Must Be Supplied To Factory From Jobsite. ANC-AT Dimensions in Inches. Construction
ANC-LI/AT ANC-AT Lay In Panel ANC-LI Dimensions in Inches Rings Per MODEL E Element D P ANC-06-LI 6 3 8 24 ANC-08-LI 8 3 10 24 ANC-10-LI 10 3 12 24 ANC-12-LI 12 3 14 24 ANC-14-LI 14 4 16 24 ANC-LI Lay
More informationOVERVIEW Combination Supply/Return Diffuser (SARM)
OVERVIEW Combination Supply/Return Diffuser (SARM) APPLICATION INFORMATION The extruded aluminum square and rectangular supply and return diffusers are designed principally for packaged roof top type heating
More informationZONE DAMPERS. Form No. PDS DAMP.0.3
90 ZONE DMPERS IRFLOW IRFLOW 90 45 0 CLS COM OPN ROUND DMPER FETURES/ENEFITS ryant zone dampers are the latest in design and were developed to fit field requirements for a variety of duct work shapes and
More informationPE-5000 DUCT STATIC PRESSURE SENSING ELEMENT
Technical Data Sheet PE-5000 DUCT STTIC PRESSURE SENSING ELEMENT DESCRIPTION Model PE-5000 units are insertion-type primary duct pressure sensing elements designed to achieve pressure signal accuracy and
More informationLinear diffuser SAL 50 Submittal
Linear diffuser SL 0 Submittal The SL0 is a diffuser with 0mm profiles wide. It is composed of extruded aluminum surfaces with eccentric rollers which slide inside and are mounted on the plenum, as well
More informationLINEAR DIFFUSERS AND BAR GRILLES
49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice
More informationGRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS
GRD PRODUCT CATALOG PRODUCTS 2018 Metal Industries, Inc. PRODUCTS Displacement Ventilation systems provide conditioned air at floor level at very low velocity and allow heat sources within the room (like
More informationD1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...
D Table of Contents, These supply, ceiling diffusers feature four handremovable modular cores. Available in steel or aluminum construction. P, P These supply, ceiling diffusers feature four handremovable
More informationW-VI Series - Internal Make-up Air Wall Canopy
W-VI Internal Make-up ir Wall Canopy With Diffuser W-VI single shell combination internal make-up air/air curtain canopy constructed of stainless steel where visible and aluminized steel where concealed.
More information6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR
C1 Table of Contents 1, 15 51, 515 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 2, 52 2FR, 2F supply,
More informationIN STAL LA TION IN STRUC TIONS FOR CON CEN TRIC DIF FUSER
IN STAL LA TION IN STRUC TIONS FOR CON CEN TRIC DIF FUSER UNIT FILTER PLENUM CONTROL MOTOR ECONOMIZER FRESH AIR EXHAUST AIR ROOF CURB FLEXIBLE DUCT CON CEN TRIC DIFFUSER BOX Concentric Diffuser Flush Mount
More information---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2
Environmental Health & Safety RADIATION PROCEDURES MANUAL Procedure Cover Sheet Procedure Title: Fume Hoods Procedure Number: EHS-08-03-REV 2 Effective Date: 18 September, 2018 ---:...-- Approved By_-=--------::.--...l~---
More informationD3-2. Table of Contents DISPLACEMENT VENTILATION
D3 Table of Contents This rectangular unit is ideal for wall or ceiling installations. B The U-shaped 180 discharge pattern and high capacity is ideal for retail spaces, commercial, or lobbies. ENGINEERING
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationL1-2. Table of Contents SECURITY GRILLES 1310, 1310TF, Introduction & Dimensional Information... L1-13
L Table of Contents 0, 0TF & 50 These perforated face supply grilles feature 5/6 diameter holes on 7/6 staggered centers. This perforated face supply grille features /6 diameter holes on 9/2 staggered
More informationK1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC
K Table of Contents, This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is 7/32., This series of extruded
More informationProduct Data. Residential Zone Dampers FEATURES/BENEFITS
Product Data Residential Zone Dampers FETURES/ENEFITS IRFLOW CLS COM OPN IRFLOW 90 0 45 ROUND DMPER CLS COM OPN 90 0 45 RECTNGULR DMPER Carrier residential zone dampers are the latest in design and were
More informationProduct Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper
CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW Fig. 3 - Slip -In Damper 05253 Fig. 1 - Round Damper 05251 FETURES/ENEFITS CLS COM OPN Carrier zone dampers are the latest in design and were
More informationProduct Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper
CLS COM OPN CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW 05253 Fig.3 Slip-InDamper Fig.1 RoundDamper 05251 FETURES/ENEFITS Carrier zone dampers are the latest in design and were developed
More information4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.
I1I Table of Contents 1/51 1M/51M These supply grilles feature individually adjustable curved blades. Available in steel or aluminum construction. /5 These single deflection supply grilles feature 3/ blade
More informationRegisters for spiral ducts
Registers for spiral ducts RGS-3 5 The RGS-3 is a supply/return register with adjustable double deflection blades and a volume damper designed specifically for direct mounting on a spiral duct. The use
More informationHORD HOSPITAL OPERATING ROOM AIR CURTAIN
HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationMODULAR CORE CEILING DIFFUSERS
MOEL SQUARE 12345-10 MOULAR CORE SQUARE IFFUSERS ROUN NECK SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSTABLE NECK SQUARE ISCHARGE ROUN PATTERN NECK Steel Model: 7500 Suffix '-O' adds a steel opposed blade damper
More informationFan-Powered Parallel
Table of Contents Service Model Number Description FPP 2 Selection Procedure FPP 3 5 General Data Valve/Controller Guidelines FPP 6 Performance Data ir Pressure Requirements FPP 7 8 Performance Data Fan
More informationSECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products
GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security
More informationCONCENTRIC Product Information & Applications
CONCENTRIC Product Information & pplications Concentrics s the leading manufacturer of Concentric Diffusers for the past 30 years, Ruskin Rooftop Systems offers a cost effective way of distributing air
More informationCCS Zone/Bypass Damper Assembly
Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control
More informationJ1-2. Table of Contents RETURN GRILLES
J1 RETURN GRILLE Table of Contents RETURN GRILLE / These fixedblade return grilles feature 3/4 blade spacing. Deflection will be fixed at 3 or. Available in aluminum or steel construction. / These fixedblade
More information4000-Series ir Handling Systems ooling, Energy Recovery, Heating & Pressurization Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com ND: 100% OUTSIDE IR ONLY 4000-Series Fan Selection
More informationLINEAR SLOT DIFFUSERS PLENUMS
LINEAR SLOT DIFFUSER PLENUMS ADAPTORS FOR MODEL SERIES 5000 LINEAR SLOT CEILING DIFFUSERS Standard Models: 5350(I) 1/2" (13) Slot 5375(I) 3/4" (19) Slot 5310(I) 1" (25) Slot Modified Performance Models:
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationHORD HOSPITAL OPERATING ROOM AIR CURTAIN
HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain
More informationSPD SQUARE PLAQUE DIFFUSER
SQUARE PLAQUE DIFFUSER The (SPD) has a flush appearance, making it ideal for architecturally-conscience commercial spaces, and provides industry-leading low pressure drop and sound generation with a 360
More informationA1-2. Table of Contents ARCHITECTURAL & PLAQUE DIFFUSERS
A1 Table of Contents PRIM features an arcuate faceplate. Center square appliqué offers nine standard colors to match interior décor. PLQ & 5PLQ features a square plaque faceplate. PLQR features a round
More informationProduct Specification Sheet Number: 319
A Series Class I Frame Blower Product Specification Sheet Number: 319 Notes: Shaded areas indicate Lau preferred product. Selections in non -shaded areas and optional features may affect price and availability.
More informationDRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION
DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers
More informationBELT DRIVEN CABINET FANS CVTT Series
Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal
More informationPSTI High Induction Diffuser
PSTI High Induction Diffuser Barcol-ir is continuously aiming to optimize construction and quality for all equipment. Barcol-ir has the right to adjust the product specifications without any obligation
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationSTATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS
STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver
More informationDIAGNOSTIC TESTING USING ASHRAE 110. Gerhard Knutson, Ph.D., CIH Knutson Ventilation, Inc
DIAGNOSTIC TESTING USING ASHRAE 110 Gerhard Knutson, Ph.D., CIH Knutson Ventilation, Inc. 952-928-0195 ASHARE 110 A Method of Testing Three components Face velocity measurements Smoke visualization Tracer
More informationCONTROL DAMPERS. Models 1810 & Model Model Model 1370
CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and
More informationFSD60/MFSD60 Multi-blade Fire Damper
DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today
More informationDCG Adjustable Aluminum Round Diffusers
51 DCG Adjustable Aluminum Round Diffusers H V A C TM Rev 27-05-2018 52 DCG SEries Aluminum Adjustable Round Diffusers Adjust core up and down to move from horizontal to vertical airflow Architecturally
More informationHOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7
HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION Exflow 28 Technical Specification Page 1 of 7 TECHNICAL SUMMARY Terminal Unit size 12-3 ¼ x 12-3 ¼ x 23 ¾ Terminal Unit weight 3527
More informationSolutions from SPTT-3
Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static
More informationFVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description
TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2100/2200 FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER MODEL 2100: Constant face velocity, variable volume MODEL 2200: Constant face velocity, variable volume
More informationCONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7
CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy
More informationPERFORATED CEILING DIFFUSERS
PERFORAE MOEL PERFORAE 12345-10 CEILING SQUARE IFFUSERS ROUN NECK SQUARE ROUN NECK SUPPLY SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSABLE NECK ISCHARGE PAERN Steel Models: 4320 Flush Face 4325 rop Face Aluminum
More informationPhotographer: BRUCE T. MARTIN, LFD Laminar Flow Diffuser
Photographer: BRUCE T. MARTIN, 2011 LFD Laminar Flow Diffuser Typical Applications The LFD s non-aspirating, unidirectional, laminar flow air pattern is ideal for applications where a low velocity and
More informationB1-2. Table of Contents LOUVERED FACE DIFFUSERS
B1 LOUEED FACE DIFFUE Table of Contents LOUEED FACE DIFFUE B12 1400, 1400F, 1400, M1400 & M1400 feature a round neck and four cones. 1400A & 1400A feature a round neck, four cones, and adjustable pattern
More informationCatalog Swirl diffuser DAL 359
Catalog 1.1.1 DAL 359 Restaurant, Lingen, Germany DAL 359 Model Description, area of application and product benefits............ DAL 359 1 Configuration...................................................
More informationB1-2. Table of Contents LOUVERED FACE DIFFUSERS
1 LOUVERED FACE DIFFUER Table of Contents LOUVERED FACE DIFFUER 12 1400, 1400FR, 1400, M1400 & M1400 These supply diffusers feature a round neck and four cones. 1400A & 1400A These supply diffusers feature
More informationADJUSTABLE SLOT DIFFUSER TYPE: SE800
TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled
More informationSquare/Rect. and Square Louvered Face and Plaque Face Diffuser
/Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationQuiet-Duct Conic-Flow Silencers Section Specifications
Quiet-Duct Conic-Flow Silencers Section 15000 Specifications 1.01 General A. Furnish and install Conic-Flow (tubular) silencers of the types and sizes shown on the plans and/or listed in the schedule.
More informationYCCS Zone/Bypass Damper Assembly
YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper are zone control and pressure control devices that include
More informationCEILING DIFFUSERS CEILING DIFFUSERS
Model 4340M Model 4330CB Premium, Curved Blade Pattern Controllers The perforated diffusers in this series have an extruded aluminum frame with a narrow border that is visible within the T-Bar module.
More informationFXV/CXV & FXV3/CXV3 Layout Guidelines
FXV/CXV & FXV3/CXV3 Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.
More informationHVAC Automatic Balance Valve Index
HVC utomatic alance Index Weights Individual Weights Y-all Models Flow Rate (GPM) Connection Size Page 2519 0.50-5.00 1/4 to 3/4 V-SPEC-2519 2518 0.50-5.00 1/2 to 3/4 V-SPEC-2518 2517 0.50-9.00 1/2 to
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationYCCS Zone/Bypass Damper Assembly
YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper Assemblies are zone control and pressure control devices that
More informationSECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products
GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security
More informationPERFORATED CEILING DIFFUSERS
PERFORAE PERFORAE CURVE MOEL BLAE 12345-10 IFFUSERS SQUARE ROUN NECK SQUARE SUPPLYROUN NECK 4-WAY AJUSABLE ISCHARGE SQUARE ROUN NECK PAERN (SANAR) 1, 2 OR 3-WAY ISCHARGE PAERN (OPIONAL) Steel Models: 4320CB
More informationApplication Guidelines
Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a
More informationAMENDMENTS Dated: August 25, 2010
AMENDMENTS Dated: August 25, 2010 The Guidelines for Air Conditioning of OT as mentioned in Glossary at page no. 114-115 is replaced by following text. Air OT Conditioning The Revised Guidelines for Air-Conditioning
More informationOnce in a while flat oval duct can be converted to the even more efficient shape of round, if the equivalent round size fits the available space.
Introduction Round is the most efficient duct shape for transporting air. Round duct has less surface area, weight and fewer joints than rectangular duct. It is much easier to seal and can easily be specified
More informationSeries. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry
Series Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry Esco scent Max Ductless Fume Hood Provides Operator and Environmental Protection Nanocarb First Diffuser Second Diffuser
More informationSUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4
SUPPLY OUN IFFUSES TBLE OF CONTENTS OUN IFFUSES 1/51 These supply ceiling diffusers discharge horizontally only. They feature three cones with two position settings to control room air induction. 2/52/2
More informationGRILLES AND REGISTERS
Heavy Duty Steel rilles and Registers, ymnasium Strength Nailor s Heavy Duty Steel rilles and Registers are manufactured with 16 gauge steel frames and 14 gauge steel blades which gives them strength to
More informationSECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products
GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationAir Handling Unit Fan Selection Guide
KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4
More informationTurning Air Into Solutions. AXIFAN VANEAXIAL & TUBEAXIAL FANS TCVS/TCTS TCVSSH/TCTSSH
Turning ir Into Solutions. XIFN VNEXIL & TUBEXIL FNS TCVS/TCTS TCVSSH/TCTSSH CTLOG X250 May 2012 Vaneaxial&TubeaxialFans Models TCVS I TCTS I TCVSSH I TCTSSH For applications requiring extensive corrosion
More informationProduct Specification Sheet Number: 305
H Series Class I & II Frame Blower Product Specification Sheet Number: 305 Notes: Shaded areas indicate Lau preferred product. Selections in non-shaded areas and optional features may affect price and
More informationJ1-2. Table of Contents RETURN GRILLES
J1 RETURN GRILLE Table of Contents RETURN GRILLE / These fixedblade return grilles feature 3/4 blade spacing. Deflection will be fixed at 3 or. Available in aluminum or steel construction. / These fixedblade
More informationV05 General Purpose Bench Fume Hood
V05 General Purpose Bench Fume Hood with Vertical Rising ash Accessories Included: 4 120 VAC 20 amp GFCI protected duplex receptacles 1 LED light fixture with illumination and color controller 1 Electronic
More informationRD-2000 Round Control Dampers
RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,
More informationGRILLES AND REGISTERS
Heavy Duty Steel rilles and Registers, ymnasium Strength Nailor s Heavy Duty Steel rilles and Registers are manufactured with 16 gauge steel frames and 14 gauge steel blades which gives them strength to
More informationFixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets
TECHNICAL BULLETIN : ACCESSORY INFORMATION Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets General NuAire Class II, Type A2 (NSF/ANSI
More informationtesto Smart Probes The SMART world of Testo HVAC
testo Smart Probes The SMART world of Testo HVAC My world just got a whole lot EASIER The most exciting development in HVAC Instruments. EVER. The biggest family of SMART instruments. Servicing heating
More informationApplication Guidelines
Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a
More informationMANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1
More informationBrass, Bronze, Iron and Stainless Steel Valves
Price Schedule June 1, 2011 Supersedes BIV-01-11 07 Brass, Bronze, Iron and Stainless Steel Valves ASTM B283 FORGED BRASS SCREW-IN BONNET NON-RISING STEM SOLID WEDGE DISC 125 WSP/200 WOG BRONZE GATE VALVES
More informationCUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER
ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot
More informationADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S
Adjusting options: Construction: diffuser: steel, painted white (RAL 9) deflector plate: steel painted black (RAL 95) plenum: galvanised steel sheet with side entry, insulated or non-insulated only suitable
More informationTotal comfort control
Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data
More informationUp to 4 x Temperature Monitoring Probes with Control Cable (1 Included) User set point control, display for Rack Face Temperature
Metric -Fan Assist 4 x EC Fans Power feed Tool less Stringer Hangers User Temperature Control Interface Up to 4 x Temperature Monitoring Probes with Control Cable (1 Included) SPECIFICATIONS General Information
More informationEngineering and Design Manual
Engineering and Design Manual 1 Shape/Suspension/Fabric Retention 2 Layout/Fittings 3 Air Dispersion 4 Fabric 5 Appendix DuctSox Corporation 2014 DSDM0114A Table of Contents/Introduction Table of Contents