J1-2. Table of Contents RETURN GRILLES

Size: px
Start display at page:

Download "J1-2. Table of Contents RETURN GRILLES"

Transcription

1 J1 RETURN GRILLE Table of Contents RETURN GRILLE / These fixedblade return grilles feature 3/4 blade spacing. Deflection will be fixed at 3 or. Available in aluminum or steel construction. / These fixedblade return grilles feature 1/2 blade spacing. Deflection will be fixed at 3 or. Available in aluminum or steel construction. P/P These perforated return grilles feature 3/16 holes on 1/4 staggered centers. Available in steel or aluminum construction. 4 This heavy duty, fixed blade, return grille features 1/2 blade spacing. Deflection will be fixed at 3 or. Available in steel construction only. 4 This heavy duty, fixed blade, return grille features 1/2 blade spacing. Deflection will be fixed at 3 or. Available in aluminum construction only. AF/AF These return grilles feature fixed blades with 3/4 or 1/2 blade spacing with 4 or deflection. Available in extruded aluminum construction only.,,, Introduction...J13 Dimensional Information...J14 Reference Charts & Performance Data...J1 Engineering pecifications...j12 P, P Introduction...J126 Dimensional Information...J127 Reference Charts & Performance Data...J129 Engineering pecifications...j134 4, 4 Introduction...J13 Dimensional Information...J136 Reference Charts & Performance Data...J13 Engineering pecifications...j1 AF, AF Introduction...J16 Dimensional Information...J161 Reference Charts & Performance Data...J164 Engineering pecifications...j179 AFC, AFC Introduction...J1 Dimensional Information...J11 Reference Charts & Performance Data...J13 Engineering pecifications...j193 EG, EG1, EG1, EGC, EGC1, EGC1 Introduction...J194 Dimensional Information...J19 Reference Charts & Performance Data...J19 Engineering pecifications...j Introduction & Dimensional Information...J111 Reference Charts & Performance Data...J1116 Engineering pecification...j1122 AFC/AFC These return grilles feature curved blades, either 3/4 blade spacing with 4 deflection or 1/2 blade spacing with 3 deflection. Available in steel construction only. EG/EGC eries This series of eggcrate return grilles feature various sized aluminum cube cores. Available as core only, with channel frame, or layin frame. J12 1 This fixedblade return grille features a removable, reversible core. Deflection may be set at or 1 up/down. Available in aluminum construction only. Excellence in Distribution

2 RETURN GRILLE J1,,, ingle Fixed Deflection Introduction:,,, The / return grilles are designed to fit most common commercial and residential applications. They offer fixed 3/4 blade spacing with 3 deflection and a 1 1/4 flange. The / return grilles are designed to fit most applications where limited sight through the grille is required. They offer fixed 1/2 blade spacing with 3 deflection and a 1 1/4 flange. If the application requires large amounts of air to be returned through the return grille, then the blade deflection of should be used to keep the pressure drop and sound to a minimum. MODEL Fixed Deflection teel Return Grille, 3/4 Blade pacing Fixed Deflection Aluminum Return Grille, 3/4 Blade pacing Fixed Deflection teel Return Grille, 1/2 Blade pacing Fixed Deflection Aluminum Return Grille, 1/2 Blade pacing FEATURE Horizontal (H) or vertical (V) front blades. 3 (H/V) or (HZ/VZ) blade deflection. ACCEORIE teel Opposed Blade Damper (Model OBD) teel Painted Opposed Blade Damper (Model POBD) Aluminum Opposed Blade Damper (Model OBD) quare to Round Adapter (Model RAC32) teel Plaster Frame (Model PF) Aluminum Plaster Frame (Model PF) 1 or 2 Filter Frame Minimum size is x and maximum is 4 x 4. (Model FF) RETURN GRILLE FINIHE tandard finish is #44 British White. Optional finishes available. Providing You With Distribution olutions J13

3 J1 RETURN GRILLE,,, ingle Fixed Deflection,,, Dimensional Information,,,, FACE VIEW, IDE VIEW, & CRO ECTION 9/16 (14) TYP DUCT IZE PLU 1 3/4 (4) DUCT IZE MINU 3/4 (19) HORIZONTAL, º BLADE PATTERN HORIZONTAL, 3º BLADE PATTERN DUCT IZE PLU 1 3/4 (4) 1 (2) VERTICAL, 3º BLADE PATTERN RETURN GRILLE HOWN WITH CLOED OBD DUCT IZE MINU 1/4 (6) 3/4 (19) 2 1/2 (64) 3/4 (19) VERTICAL, º BLADE PATTERN 2 1/2 (64),,,, FRAME TYLE,,,, CONCEALED MOUNTING 1 (2) 9/16 (14) 1 1/4 (32) 1/4 (6) 1 (2) PANEL MINU 1/4 (6) 1/4 (6) 1 (2) PANEL MINU 1/4 (6) PANEL MINU / (16) /16 () ANGLE BY OTHER # CREW BY OTHER 3/4 x1 1/4 (19X32) ANGLE EXITING DUCT FRAME 22 FRAME 23 FRAME 9 GRILLE FRAME,,,, FILTER FRAME MOUNTING MAXIMUM DUCT IZE = PANEL IZE MINU " (127) 1" FILTER FRAME 2 /" (66) 2" FILTER FRAME 3 /" (92) PANEL IZE MINU 1/4" (6) NOMINAL DUCT PLU 1/4" (6) PANEL IZE MINU 1/4" (6) KNURLED KNOB, FRAME 23 KNURLED KNOB, FRAME 9 NOTE: Dimensions in parentheses are mm. FILTER BY OTHER GRILLE FRAME PANEL IZE MINU /" (16) /16" () FILTER BY OTHER NOMINAL DUCT PLU 1/4" (6) DUCT PLU 3 3/4" (96) 1" FILTER FRAME, ALUM. 2 3/" (62) TEEL 2 /" (66) 2" FILTER FRAME, 3 /" (92) 1/4 TURN FATENER, FRAME 22 J14 Excellence in Distribution

4 RETURN GRILLE J1, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) 34 ize 1" x 24" " x 27" 1" x 1" 6" x 22" 6" x 1" " x 12" 6" x 12" 6" x 1" 6" x 6" RETURN GRILLE flow (CFM) ize 1" x 42" 1" x 36" 1" x 3" 14" x 36" 16" x 3" 2" x 2" 12" x 3" 1" x 1" 16" x 16" ound Level, NC Providing You With Distribution olutions J1

5 J1 RETURN GRILLE, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) RETURN GRILLE flow (CFM) ound Level, NC AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 3" x 42" 36" x 42" 3" x 4" 3" x 42" 34" x 34" 3" x 36" 22" x 46" 3" x 3" 2" x 3" ize 4" x 4" 46" x 4" 46" x 46" 42" x 4" 44" x 44" 42" x 42" 36" x 4" J16 Excellence in Distribution

6 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J19. Providing You With Distribution olutions J17 RETURN GRILLE

7 RETURN GRILLE J1 J1 RETURN GRILLE, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J19. Excellence in Distribution

8 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: NC values are based on octave band 2 7 sound power levels minus a room absorption of 1dB, re 1 12 Watts. Dash in space denotes a NC or db value of less than 1. Data was obtained from tests conducted in accordance with ANI/AHRAE tandard 7, IO tandard 219, and IO tandard ee Krueger s selection program for performance data not shown, including octave band data. Providing You With Distribution olutions J19 RETURN GRILLE

9 J1 RETURN GRILLE, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) ize flow (CFM) " x 24" " x 27" 1" x 1" 6" x 22" 6" x 1" " x 12" 6" x 12" 6" x 1" 6" x 6" 3 2 RETURN GRILLE ound Level, NC AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 1" x 42" 1" x 36" 1" x 3" 14" x 36" 16" x 3" 2" x 2" 12" x 3" 1" x 1" 16" x 16" J11 Excellence in Distribution

10 RETURN GRILLE J1, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 3" x 42" 36" x 42" 3" x 4" 3" x 42" 34" x 34" 3" x 36" 22" x 46" 3" x 3" 2" x 3" ize 4" x 4" 46" x 4" 46" x 46" 42" x 4" 44" x 44" 42" x 42" 36" x 4" Providing You With Distribution olutions J111 RETURN GRILLE

11 RETURN GRILLE J1 J112 RETURN GRILLE, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J Excellence in Distribution

12 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J114. Providing You With Distribution olutions J113 RETURN GRILLE

13 J1 RETURN GRILLE, ingle Fixed Deflection, Performance Data RETURN GRILLE IP/METRIC DATA:,, DEFLECTION (NO DAMPER) J114 IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: NC values are based on octave band 2 7 sound power levels minus a room absorption of 1dB, re 1 12 Watts. Dash in space denotes a NC or db value of less than 1. Data was obtained from tests conducted in accordance with ANI/AHRAE tandard 7, IO tandard 219, and IO tandard ee Krueger s selection program for performance data not shown, including octave band data. Excellence in Distribution

14 RETURN GRILLE J1, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 1" x 24" " x 27" 1" x 1" 6" x 22" 6" x 1" " x 12" 6" x 12" 6" x 1" 6" x 6" ize 1" x 42" 1" x 36" 1" x 3" 14" x 36" 16" x 3" 2" x 2" 12" x 3" 1" x 1" 16" x 16" Providing You With Distribution olutions J11 RETURN GRILLE

15 J1 RETURN GRILLE, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) RETURN GRILLE flow (CFM) ound Level, NC AIRFLOW V. NC:,, 3 DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 3" x 42" 36" x 42" 3" x 4" 3" x 42" 34" x 34" 3" x 36" 22" x 46" 3" x 3" 2" x 3" ize 4" x 4" 46" x 4" 46" x 46" 42" x 4" 44" x 44" 42" x 42" 36" x 4" J116 Excellence in Distribution

16 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J119. Providing You With Distribution olutions J117 RETURN GRILLE

17 RETURN GRILLE J1 J11 RETURN GRILLE, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data NOTE: ee notes on page J119. Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " Excellence in Distribution

18 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, 3 DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: NC values are based on octave band 2 7 sound power levels minus a room absorption of 1dB, re 1 12 Watts. Dash in space denotes a NC or db value of less than 1. Data was obtained from tests conducted in accordance with ANI/AHRAE tandard 7, IO tandard 219, and IO tandard ee Krueger s selection program for performance data not shown, including octave band data. Providing You With Distribution olutions J119 RETURN GRILLE

19 J1 RETURN GRILLE, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ize 1" x 24" " x 27" 1" x 1" 6" x 22" 6" x 1" " x 12" 6" x 12" 6" x 1" 6" x 6" 32 2 RETURN GRILLE ound Level, NC AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ize 1" x 42" 1" x 36" 1" x 3" 14" x 36" 16" x 3" 2" x 2" 12" x 3" 1" x 1" 16" x 16" ound Level, NC J12 Excellence in Distribution

20 RETURN GRILLE J1, ingle Fixed Deflection, Reference Charts AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC AIRFLOW V. NC:,, DEFLECTION (NO DAMPER) flow (CFM) ound Level, NC ize 3" x 42" 36" x 42" 3" x 4" 3" x 42" 34" x 34" 3" x 36" 22" x 46" 3" x 3" 2" x 3" ize 4" x 4" 46" x 4" 46" x 46" 42" x 4" 44" x 44" 42" x 42" 36" x 4" Providing You With Distribution olutions J121 RETURN GRILLE

21 RETURN GRILLE J1 J122 RETURN GRILLE, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, DEFLECTION (NO DAMPER) IP Data NOTE: ee notes on page J124. Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " Excellence in Distribution

22 RETURN GRILLE J1, ingle Fixed Deflection, Performance Data IP/METRIC DATA:,, DEFLECTION (NO DAMPER) IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: ee notes on page J124. Providing You With Distribution olutions J123 RETURN GRILLE

23 J1 RETURN GRILLE, ingle Fixed Deflection, Performance Data RETURN GRILLE IP/METRIC DATA:,, DEFLECTION (NO DAMPER) J124 IP Data Metric Data Octave Band, db NC in ft² FPM CFM "WG mm m² m/s L/s Pa " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " " x x " NOTE: NC values are based on octave band 2 7 sound power levels minus a room absorption of 1dB, re 1 12 Watts. Dash in space denotes a NC or db value of less than 1. Data was obtained from tests conducted in accordance with ANI/AHRAE tandard 7, IO tandard 219, and IO tandard ee Krueger s selection program for performance data not shown, including octave band data. Excellence in Distribution

24 ,,, uggested pecification & Configuration RETURN GRILLE J1,,, ingle Fixed Deflection 1. ERIE: (XXXX) ingle Fixed Deflection, 3/4 pacing, teel Return Grille ingle Fixed Deflection, 3/4 pacing, Aluminum Return Grille ingle Fixed Deflection, 1/2 pacing, teel Return Grille ingle Fixed Deflection, 1/2 pacing, Aluminum Return Grille 2. PATTERN: (XX) H 3 Horizontal Front Blades V 3 Vertical Front Blades HZ Horizontal Front Blades VZ Vertical Front Blades 3. WIDTH: (XX) 6 96 in 2 Increments 4. HEIGHT: (XX) 4 96 in 2 Increments. FRAME: (XXX) F22 urface Mount F23 Layin TBar 6. PANEL: (XX)x(XX)* NONE 24 x24 24 x4 7. FATENING METHOD: (XX) No crew Holes 1 tandard crew Holes 3 Knurled Knob ** 1/4 Turn Fasteners **, The return grille shall be a Krueger model (steel) or (aluminum). This grille must have 3 deflection (H and V models) or deflection (HZ and VZ models) blades on 3/4 centers made of 22 gage steel () or roll formed aluminum (). The blades must be held in place by mullions placed behind the grille and welded to the frame. The frame of the grille must be constructed of 22 gage steel () or roll formed aluminum with minimum.32 thickness () for sizes less than and equal to 24 x24 and extruded aluminum with nominal thickness.4. for sizes greater that 24 x24 with countersunk screw holes. This frame must also produce a border of 1 1/4 around all sides of the grille with mitered corners. Optional damper shall be available made of heavy gage steel (OBD) or aluminum (OBD) and operable from the face of the return grille., The return grille shall be a Krueger model (steel) or (aluminum). This grille must have 3 deflection (H and V models) or deflection (HZ and VZ models) blades on 1/2 centers made of 22 gage steel () or roll formed aluminum (). The blades must be held in place by mullions placed behind the grille and welded to the frame. The frame of the grille must be constructed of 22 gage steel () or roll formed aluminum with minimum.32 thickness () for sizes less than and equal to 24 x24 and extruded aluminum with nominal thickness.4. for sizes greater that 24 x24 with countersunk screw holes. This frame must also produce a border of 1 1/4 around all sides of the grille with mitered corners. Optional damper shall be available made of heavy gage steel (OBD) or aluminum (OBD)and operable from the face of the return grille. RETURN GRILLE. DAMPER: (XX) No Damper 1 teel Opposed Blade Damper (Model OBD) 1 Aluminum Opposed Blade Damper (Model OBD) 9. ACCEORIE: (XX) (XX) No Accessories 1 Plaster Frame 4 1 Filter *** 2 Filter *** 1.FINIH: (XX) 1 Mill 1 Alumican 3 Black 44 British White * Minimum of 4 difference required between neck and panel size. ** Maximum single piece unit size is 4 x4. *** Knurled Knob and 1/4 Turn Fastening Methods are only available with filter frame accessories. AMPLE CONFIGURATION: HZ 1x12 F22 NONE PERFORMANCE The manufacturer shall provide published (printed or electronic) performance data for the diffuser. Performance data shall include 2 7 octave band sound power levels. The diffuser shall be tested in accordance to the data standards at the time of product introduction or ANI/AHRAE tandard 7. FINIH The paint finish shall be #44 British White and be an anodic acrylic paint, baked at 31 F for 3 minutes. The paint thickness shall be. 1. mils, gloss at 6 per ATM D23 9 of %, pencil hardness per ATM D336392A of HB H, crosshatch adhesion per ATM D3393 of 4B B, impact per ATM D of direct impact >1 in/lb and reverse impact > in/lb, salt spray per ATM B11794 of 96 hours, humidity per ATM D of > hours and water soak per ATM D792 of 2 hours. Providing You With Distribution olutions J12

J1-2. Table of Contents RETURN GRILLES

J1-2. Table of Contents RETURN GRILLES J1 RETURN GRILLE Table of Contents RETURN GRILLE / These fixedblade return grilles feature 3/4 blade spacing. Deflection will be fixed at 3 or. Available in aluminum or steel construction. / These fixedblade

More information

L1-2. Table of Contents SECURITY GRILLES 1310, 1310TF, Introduction & Dimensional Information... L1-13

L1-2. Table of Contents SECURITY GRILLES 1310, 1310TF, Introduction & Dimensional Information... L1-13 L Table of Contents 0, 0TF & 50 These perforated face supply grilles feature 5/6 diameter holes on 7/6 staggered centers. This perforated face supply grille features /6 diameter holes on 9/2 staggered

More information

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC K Table of Contents, This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is 7/32., This series of extruded

More information

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information... D Table of Contents, These supply, ceiling diffusers feature four handremovable modular cores. Available in steel or aluminum construction. P, P These supply, ceiling diffusers feature four handremovable

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C1 Table of Contents 1, 15 51, 515 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 2, 52 2FR, 2F supply,

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS 1 LOUVERED FACE DIFFUER Table of Contents LOUVERED FACE DIFFUER 12 1400, 1400FR, 1400, M1400 & M1400 These supply diffusers feature a round neck and four cones. 1400A & 1400A These supply diffusers feature

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS B1 LOUEED FACE DIFFUE Table of Contents LOUEED FACE DIFFUE B12 1400, 1400F, 1400, M1400 & M1400 feature a round neck and four cones. 1400A & 1400A feature a round neck, four cones, and adjustable pattern

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C Table of Contents 6, 6 6, 6 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 62, 62 62FR, 629F supply,

More information

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only. I1I Table of Contents 1/51 1M/51M These supply grilles feature individually adjustable curved blades. Available in steel or aluminum construction. /5 These single deflection supply grilles feature 3/ blade

More information

A1-2. Table of Contents ARCHITECTURAL & PLAQUE DIFFUSERS

A1-2. Table of Contents ARCHITECTURAL & PLAQUE DIFFUSERS A1 Table of Contents PRIM features an arcuate faceplate. Center square appliqué offers nine standard colors to match interior décor. PLQ & 5PLQ features a square plaque faceplate. PLQR features a round

More information

ROUND DIFFUSERS G1. RM, RA Series Cone Diffusers. Introduction: RM, RA Series ROUND DIFFUSERS R M - R A S E R I E S

ROUND DIFFUSERS G1. RM, RA Series Cone Diffusers. Introduction: RM, RA Series ROUND DIFFUSERS R M - R A S E R I E S OUND DIFFUSES G, A Series Cone Diffusers Introduction:, A Series Krueger s /A round ceiling diffusers provide excellent performance in variable air volume systems. The round ceiling diffusers have three

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS Table of Contents 2, FR,, M & M feature a round neck and four cones. & feature a round neck, four cones, and adjustable pattern controllers.,, M, & M feature a round neck and three cones. & feature a round

More information

CRNRR, 5CRNRR These concentric ring nozzles feature a stub duct mounting frame for smaller duct work

CRNRR, 5CRNRR These concentric ring nozzles feature a stub duct mounting frame for smaller duct work H1 AI NOZZLES & OUN GILLES Table of Contents AI NOZZLES & OUN GILLES PN This round punkah nozzle features a surface mounting frame. PN This round punkah nozzle features a stub duct mounting frame. PN This

More information

M1-2. Table of Contents INDUSTRIAL GRILLES. 680, 5680, 6880, 56880, 680MP, 5680MP Introduction... M1-3 Dimensional Data... M1-4

M1-2. Table of Contents INDUSTRIAL GRILLES. 680, 5680, 6880, 56880, 680MP, 5680MP Introduction... M1-3 Dimensional Data... M1-4 1 Table of Contents & These industrial supply grilles feature adjustable, single deflection, extruded aluminum airfoil blades with a steel or extruded aluminum frame. Horizontal or vertical blades at 1

More information

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts...

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts... F1 LENUM LO DIFFUE able of ontents his plenum slot supply diffuser features an adjustable blade. lots: 1 to 4 lot Widths: ¾, 1, 1½ Introduction & Dimensional Information... F13 Accessories... F15 eference

More information

SUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4

SUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4 SUPPLY OUN IFFUSES TBLE OF CONTENTS OUN IFFUSES 1/51 These supply ceiling diffusers discharge horizontally only. They feature three cones with two position settings to control room air induction. 2/52/2

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

D3-2. Table of Contents DISPLACEMENT VENTILATION

D3-2. Table of Contents DISPLACEMENT VENTILATION D3 Table of Contents This rectangular unit is ideal for wall or ceiling installations. B The U-shaped 180 discharge pattern and high capacity is ideal for retail spaces, commercial, or lobbies. ENGINEERING

More information

LAMINAR FLOW DIFFUSER Model DLAB

LAMINAR FLOW DIFFUSER Model DLAB Laminar & Radial Flow Diffuser LAMINAR FLOW DIFFUSER Model DLAB Application Laminar Flow diffusers are used to deliver air to surface directly underneath in a non-aspirating air pattern, with the minimum

More information

Wall and Ceiling Grille

Wall and Ceiling Grille September 14 Wall and Ceiling Grille Models SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW Single and Double Deflection Fixed and Removable Core Eggcrate Perforated Grille 45 Fixed Blade Non Vision Bar Grilles

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR SLOT DIFFUSER PLENUMS FOR TECHZONE TYPE CEILINGS Model Series 5300TZ Plenums are designed to fit the 5000TZ Series Slot Diffusers.

More information

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security

More information

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way) Fixed Bar Grills - Series G Description Caryaire Fixed Bar Grills are ideal for Supply as well as Return air, in both Cooling as well as Heating. It can be used in high side wall or ceiling applications.

More information

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers

More information

EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS

EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS SAUDI AIR CONTROL SYSTEM INDUSTRIAL REGISTRATION NO.353 EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS SERIES GLG and GLR 1, 2, 3, 4/5,6,7,8,9,10.

More information

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS ECRATE RETURN AND EXHAUST RILLES The eggcrate grilles and registers are constructed of thin, interlocked aluminum or stainless steel strips assembled in a square grid fashion that is available in a variety

More information

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

makes sure products are delivered Products are offered in steel,

makes sure products are delivered Products are offered in steel, Residential Construction Features Residential Registers, Grilles & Diffusers No one satisfies the demands for For example: an electro-deposition air distribution solutions better than paint creates a flawless

More information

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

Square/Rect. and Square Louvered Face and Plaque Face Diffuser /Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Models 51EC, 67EC Models 51PR, 67PR Eggcrate Return and Exhaust rilles The eggcrate grilles and registers are constructed of thin, interlocked aluminum or stainless steel strips assembled in a square grid

More information

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D

for Pleasant & Healthy Air-Distribution   ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D for Pleasant & Healthy Air-Distribution ISO 90012000 Product Bulletin 135-D Linear Bar & Floor Grilles Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION DASCO Linear Bar

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

MODULAR CORE CEILING DIFFUSERS

MODULAR CORE CEILING DIFFUSERS MOEL SQUARE 12345-10 MOULAR CORE SQUARE IFFUSERS ROUN NECK SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSTABLE NECK SQUARE ISCHARGE ROUN PATTERN NECK Steel Model: 7500 Suffix '-O' adds a steel opposed blade damper

More information

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Premium Correctional Air Distribution. The First Name in Air Diffusion. Premium Correctional Air Distribution The First Name in Air Diffusion www.anemostat.com PRODUCT DIRECTORY APPLICATIONS Stainless Steel S-Vent MAXIMUM SECURITY GRILLES NEW CONSTRUCTION page 16 page 4 &

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air ISSUE B, OCT 2009 Architectural Square Ceiling Diffusers UNI & AUNI Diffusers Product Overview - Uni Series Architectural Ceiling Diffusers Uni Series High Performance Square Face Round Neck The Model

More information

LINEAR SLOT DIFFUSERS PLENUMS

LINEAR SLOT DIFFUSERS PLENUMS LINEAR SLOT DIFFUSER PLENUMS ADAPTORS FOR MODEL SERIES 5000 LINEAR SLOT CEILING DIFFUSERS Standard Models: 5350(I) 1/2" (13) Slot 5375(I) 3/4" (19) Slot 5310(I) 1" (25) Slot Modified Performance Models:

More information

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot

More information

Series DD & SD-20 Supply Grilles & Registers

Series DD & SD-20 Supply Grilles & Registers Series DD & SD-20 Supply Grilles & Registers Grille - Two Sets of Louver Blades Model DDL-20 Two sets of louver blades. Front set parallel to long dimension. Rear set parallel to short dimension. All louver

More information

CEILING DIFFUSERS D12 CEILING DIFFUSERS

CEILING DIFFUSERS D12 CEILING DIFFUSERS PREMIUM This perforated return has an extruded aluminum frame with a narrow border that is visible within the T-Bar module. See Model Series 4330 and 4330CB for the matching supply air diffusers. Flush

More information

SPECIFICATIONS T70FB, T80FB, T75FB, T85FB Series

SPECIFICATIONS T70FB, T80FB, T75FB, T85FB Series T70FB, T80FB, T75FB, T85FB Series T70FB, T70DFB, T80FB, T80DFB Suggested T75FB, T75DFB, T85FB, T85DFB Suggested The steel filter return grille shall be Tuttle & Bailey model T70FB (horizontal bars) or

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Heavy Duty Steel rilles and Registers, ymnasium Strength Nailor s Heavy Duty Steel rilles and Registers are manufactured with 16 gauge steel frames and 14 gauge steel blades which gives them strength to

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS RILLES AND REISTERS Models 45DL1, 45DL2 Models 813SH-O, 813DV Drum Louvers These extruded aluminum drum louvers are appropriate when high volumes of air are used and in spot heating and cooling applications.

More information

fsfdfsdfsdfssfsf OMNI DIFFUSER

fsfdfsdfsdfssfsf OMNI DIFFUSER fsfdfsdfsdfssfsf OMNI DIFFUSER Architectural Ceiling Diffusers diffusers OMNI The Titus OMNI diffuser satisfies architectural as well as engineering criteria. Its strong, clean, unobtrusive lines harmonize

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units

More information

SPD/SPDV SPD SPDV. High Velocity/High Aspiration Air Outlet. Construction

SPD/SPDV SPD SPDV. High Velocity/High Aspiration Air Outlet. Construction SPD/SPDV SPD O D-1/8 C Saturn Plaque Diffuser US Patent B H SPDV SPD Dimensions in Inches MODEL A B C D H O SPD-04 7-1/2 2 1-1/4 4 3-3/4 5-1/8 SPD-06 10 2 1-3/16 6 4 7-1/2 SPD-08 12 2 1-3/16 8 4 9-1/2

More information

NAILOR COMMERCIAL REGISTERS, GRILLES AND DIFFUSERS

NAILOR COMMERCIAL REGISTERS, GRILLES AND DIFFUSERS INDEX CEILING DIFFUSERS... 9-2 ARCHITECTURAL (LAY-IN T-BAR)... 9-2 SQUARE (LAY-IN T-BAR ) 3 CONE... 9-2 SQUARE (LAY-IN T-BAR) 4 CONE... 9-2 SQUARE (LAY-IN T-BAR) ADJUSTABLE SLIDING TYPE... 9-2 SQUARE (PANEL

More information

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles Incorporating V2.1 Product spec >>> > Series ECG - Egg crate grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract grille Plastic egg crate core optional

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS RILLES AND REISERS CURVED SPIRAL DUC RILLES Nailor s unique curved spiral duct grille design offers an architecturally superior appearance and saves installation time and money by directly mounting to

More information

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32. STEEL LOUVERED DIFFUSERS TUTTLE & BAILEY Model 1300 - Round Neck Steel, Lay-In Tee Bar Mounting Neck Size Panel Size CFM Range Price Each Volume Damper Model RBN *6 12 x 12 75-180 $19 $12 6 24 x 24 75-180

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Heavy Duty Steel rilles and Registers, ymnasium Strength Nailor s Heavy Duty Steel rilles and Registers are manufactured with 16 gauge steel frames and 14 gauge steel blades which gives them strength to

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS AIRFOIL BLADE RETURN AIR 45 DEFLECTION, 3/4 () BLADE SPACIN The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location with grille blade deflection

More information

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles Incorporating V2.0 Product spec >>> > Series DD - Double deflection grilles Grilles Double deflection Recommended for: Wall, ceiling & duct Supply & extract Overview Enhanced functionality As per the name,

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS RILLES AND REISTERS RETURN AIR FIXED BARS This return air grille has extruded aluminum fixed blades that are reinforced for strength. Models H-HD, V-HD, FH-HD, FV-HD Page 1 Suffix '-O' adds a steel OBD

More information

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof OVERVIEW Linear Bar, Grilles and Registers OVERVIEW LINEAR BAR, GRILLES and REGISTERS Curtainaire Trimaire Varicore Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

CEILING DIFFUSERS CEILING DIFFUSERS

CEILING DIFFUSERS CEILING DIFFUSERS Model 4340M Model 4330CB Premium, Curved Blade Pattern Controllers The perforated diffusers in this series have an extruded aluminum frame with a narrow border that is visible within the T-Bar module.

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS RILLES AND REISERS HEAVY DUY SAINLESS SEEL his grille is used mainly for return air applications that require strength and durability in corrosive or high humidity environments. he frame is welded and

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE MOEL PERFORAE 12345-10 CEILING SQUARE IFFUSERS ROUN NECK SQUARE ROUN NECK SUPPLY SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSABLE NECK ISCHARGE PAERN Steel Models: 4320 Flush Face 4325 rop Face Aluminum

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Curved Spiral Duct rilles Nailor s unique curved spiral duct grille design offers an architecturally superior appearance and saves installation time and money by directly mounting to the duct. This eliminates

More information

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially

More information

Steel Single Deflection Supply Grille, Register (RSSB, RTSB)

Steel Single Deflection Supply Grille, Register (RSSB, RTSB) Steel Single Deflection Supply Grille, Register (RSSB, RTSB) 1-3/8 2-9/16 Listed Size +2 Listed Size - 2/3 Listed Size 1-1/4 Listed Size +2 3/4 Application: Single Deflection Supply R&G provide a discharge

More information

product description model AL UP TO 120" SINGLE PIECE CONSTRUCTION REDUCES JOINTS Airline Linear Grilles & Registers Aluminum Bar Grilles & Registers

product description model AL UP TO 120 SINGLE PIECE CONSTRUCTION REDUCES JOINTS Airline Linear Grilles & Registers Aluminum Bar Grilles & Registers product description APPLICATION UP TO 120" PIC CONSTRUCTION RDUCS JOINTS Recommended for heating, cooling, or general ventilation applications Supply or return air systems Sill installation blankets glass

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS HEAVY DUTY STAINLESS STEEL This grille is used mainly for return air applications that require strength and durability in corrosive or high humidity environments. The frame is welded and the blades are

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE PERFORAE CURVE MOEL BLAE 12345-10 IFFUSERS SQUARE ROUN NECK SQUARE SUPPLYROUN NECK 4-WAY AJUSABLE ISCHARGE SQUARE ROUN NECK PAERN (SANAR) 1, 2 OR 3-WAY ISCHARGE PAERN (OPIONAL) Steel Models: 4320CB

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

* Acoustical Tile Must Be Supplied To Factory From Jobsite. ANC-AT Dimensions in Inches. Construction

* Acoustical Tile Must Be Supplied To Factory From Jobsite. ANC-AT Dimensions in Inches. Construction ANC-LI/AT ANC-AT Lay In Panel ANC-LI Dimensions in Inches Rings Per MODEL E Element D P ANC-06-LI 6 3 8 24 ANC-08-LI 8 3 10 24 ANC-10-LI 10 3 12 24 ANC-12-LI 12 3 14 24 ANC-14-LI 14 4 16 24 ANC-LI Lay

More information

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise EYELASH DIFFUSERS E SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 71526 - Fax: 01707 71 527 - email sales@jprservices.co.uk

More information

All-steel construction For installation of #16 diffuser when not using a damper. Golden Sand enamel finish. 12 Butterfly Damper

All-steel construction For installation of #16 diffuser when not using a damper. Golden Sand enamel finish. 12 Butterfly Damper 11 Duct Ring All-steel For installation of #16 diffuser when not using a damper Golden Sand enamel finish Size A 6 7-1/2 8 9-1/2 10 10-7/8 12 12-7/8 14 14-7/8 18 18-3/16 11 Available Sizes (in.) 6, 8,

More information

CONCENTRIC Product Information & Applications

CONCENTRIC Product Information & Applications CONCENTRIC Product Information & pplications Concentrics s the leading manufacturer of Concentric Diffusers for the past 30 years, Ruskin Rooftop Systems offers a cost effective way of distributing air

More information

Price O.R. Systems AIR CURTAIN SYSTEM

Price O.R. Systems AIR CURTAIN SYSTEM Price O.R. Systems AIR CURTAIN SYSTEM The Price Air Curtain System includes non-aspirating laminar flow diffusers directly above the surgical area with a surrounding four-sided linear slot diffuser system

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available: Model ABV Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: Application: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

Plastic Diffusers & Grilles

Plastic Diffusers & Grilles Diffusers & Grilles No rust, no corrosion Won t fade or yellow Scratches don t show No painting or repainting Won t bend Mildew resistant Consistent smooth finish Indistinguishable from metal when installed

More information

RPD ROUND PLAQUE DIFFUSER

RPD ROUND PLAQUE DIFFUSER ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide PELICANTM Wall Rectangular perforated wall air diffusers for supply air Quick facts Flexible air distribution pattern, easy to set Cleanable, removable damper Simple commissioning, fixed measurement tapping

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

critical environment diffusers

critical environment diffusers FlowBar Critical Environment Diffusers Hard Diffusers Ceiling Table Applications of Contents 2 CRITICAL ENVIRONMENT DIFFUSERS Critical Environment Diffusers... 3 Applications... 3 General Clean Room Information...

More information