1 Jon Konings Former CEM Coordinator
2 Not covering every detail of these QA topics. There is such a wide variation in the configuration of hardware out there, and I can t cover everything, so I will address general terms and issues. I don t have all the answers, but I hope I can open your eyes and help you be better prepared and ready for success. 2
3 This protocol is only available to Gas fired peaking * units, or Oil fired peaking * units * Peaking units are those units with an: Average capacity factor of not more than 10% over the past 3 years, and Of those three years, no one year can have a capacity factor of > 15%. Units which have low capacity factors also have low total mass emissions for the year. Capacity factor = total actual accumulated annual load/total maximum hourly load times 8760 Each year the operator must update the Qualification Record for peaking status with either actual historical capacity data or projected capacity data. 3
4 Appendix E is based on the alternate way to calculate heat input from Appendix D, and then to indirectly to calculate an hourly NOx emission rate, based on previous testing. The NOx estimation protocol replaces operating NOx & O2/CO2 monitors. The hourly heat input value from Appendix D is extended to and used by the Appendix E protocol. Through NOx testing at four different operating levels, a response curve is developed of heat input versus NOx emission rate. After testing, the calculated hourly heat input value is used with the correlation curve to estimate the hourly NOx emission rate. Let s look at a sample Heat Input vs. NOx lb./mmbtu curve. 4
5 5
6 Notice the four different operating levels. The curve extends horizontally from the lowest testing level to the zero heat input on the X axis. And notice the highest operating level (level 4). We use the hourly heat input (MMBtu/hr.) to calculate or predict a NOx emission rate (NOx lb./mmbtu). This is an example of a PEMS Predictive Emission Monitoring System 6
7 I recommend that the Appendix E reporting protocol should only be used for P75 reporting purposes. We have seen a few reporting conditions outside of P75 where NOx correlation was allowed but ran into issues when the missing data values reported lead to exceedances. The NOx hourly averages were not intended to be used in extended averages, like 3-hour or 24 hour averages. For Appendix E, special missing data algorithms for: missing fuel flow periods, i.e. no hourly heat input. When the hourly heat input readings are higher than the highest heat input testing level (can be up to 1.25 times the highest NOx rate tested or up to MER. When one of the operating quality assurance parameters are missing 7
8 First, the NOx Correlation module must be enabled after purchasing. It s special software. The On-line Help for Appendix E information in SV Past NOx Correlation records found in StackVision Part 75 Policy Manual Section 24 Appendix E Plain English Guide to Part 75 Rule really good 8
9 1. Launching the NOx Correlation feature- Tools > QA and Certification > NOx Correlation 2. Adding a NOx Correlation Record a 5 step wizard to step up the record 3. Importing a NOx Correlation Record a 5 step wizard for importing older flat-file EDRs. 4. Selecting Protocol Gas Certificates- these are the cylinders the stack testers used on their monitors. They must be loaded into Cal Gas Management module first. 5. Entering AETB Data this info can be imported via Excel template that can be exported from SV first. 9
10 6. Associating AETB Data with a NOx Correlation test a six step process. 7. Adding additional Correlated parameters- wizard walk you through the steps will 8. Retrieving Minute Data after each run, the corresponding operating data needs to be retrieved. 9. Calculating the Reference Mean after the NOx lb./mmbtu rates are entered for each run, calculate the reference mean 10. Configuring NOx Correlation alarms review carefully to decide how best to use. 10
11 In (a)(1) addresses initial certification or recertification, and written notification is required, but there are some exceptions, except as provided in paragraphs (a)(1)(iii), (a)(1)iv) and (a)(4) of this section. Read these exceptions carefully. In any case, a courtesy to the local or state agency outlining your plans for using the Appendix E protocol isn t a bad idea either. They are going to receive your hardcopy certification package down the road for their approval. 11
12 For initial certification or recertification, a notification is required 21 days prior to the first scheduled day of testing. Check out (a)(5) for details about this requirement. This notification process has two parts to it: First, submitting the electronic Monitoring Plan records through ECMPS. Second, submitting a hard copy package, incompatible with the electronic format, consisting of: Copy of the Monitoring Plan records, Test protocols, or many, many other special documents. This hard copy notification package goes to the EPA s regional office and to your local or state environmental agency. On-going retesting for Appendix E also have a 21 notice provision to CAMD, but the regulations allow regulatory agencies to issue a notice waiver. And CAMD has issued a waiver! You need to verify if your state or the regional EPA office has issued a waiver or still requires to be notified. I am not aware of any state having issued a notice waiver. 12
13 The idea behind the Monitoring Outline is to layout how this alternative or excepted monitoring system will operate. Again, this is not officially required but I used it to prepare this simple outline as the precursor to the QAQC plan. This protocol is a different way, so sit down and think this process through. At a minimum, an outline for Appendix E should include: 1. A description of how the four operating levels will be selected and determined. 2. Which four operating parameters will be used to check the NOx operating conditions 3. How wide the tolerance band is being set for these operating parameters 4. A description of the process for deciding how wide to set these tolerance bands. 5. A statement that the DAHS will follow the Appendix E missing data substitution requirements through StackVision. 13
14 1. The first step is identify the four operating levels and the sequence of the operating levels is very important. Why? Let s call the four levels the following. Lowest the lowest safe, sustainable and stable operating level, Low-mid, Mid-high, Highest this needs to be the highest, safe and sustainable load achievable today. The lowest level should be tested first, followed by the highest. Extend out the curve as far as possible. Now that you know the top and bottom, select the two mid loads. Break up this gap with the two mid loads equally spaced. 14
15 1. Here is an example. Say our unit is rated at 100 MWs for it s maximum. Let s call the four levels the following. Lowest level is tested first we are able to hold 40 MWs easily and test there first. Highest level comes next. We manage to hold 97 MWs today and test there next. The gap between highest and lowest is 57MWs. Divide this gap into thirds, or 19 MWs. Low-mid level is tested at 59 MWS (40+19), Mid-high level is tested at 78 MW ( = 78, or = 78). After testing at the lowest and then the highest, the testing sequence for the last two loads isn t as important and you could leave it up to the operator to decide what order he wants. Work with the operators ahead of time to get the load levels you want in the sequence that you want. 15
16 2. From your in house procedure, identify the four operating parameters than are tracked for NOx emissions. On combustion turbines, if water or steam injection is used, then Appendix E requires that either the injection rate or the fuel-to-water/steam ratio is one of the four operating parameters. For boilers, the excess O2 level must be one of the four operating parameters. These operating parameters control or contribute to the formation of NOx emissions by controlling the combustion process. They might be: Inlet guide vane position, Compressor temperature, Compressor pressure, Outlet temperature, Or other parameters recommended by the OEM (Original Equipment Manufacturer) 16
17 3. While holding the operating load steady at each of the four levels, the stack testers will use reference methods to measure the NOx ppm concentration and the emission rate in lbs./mmbtu). They must record data for at least three runs at each operating level. Use the Wizard to add a NOx Correlation record. At the Main Menu, select : Tools QA and Certification and then NOx Correlation. Use the Add icon add a new record. In the Wizard screens, you will have to enter or select: When the last test was completed, The reason for the Test, Fuel Flow Measurement Type, Fuel Type, And a lot of other information. Having a written out in-house procedure to follow will make setting up these records much easier, 17
18 4. While the stack testers were measuring the NOx data, you need to set up the NOx Correlation records to retrieve from the minute database the corresponding information for: Average heat input recorded during each testing run. Average load recorded during each test rim. The average value recorded for each of the four operating parameters during each test run. Since the test runs are not typically an hour long, the actual recorded values will be converted to hourly averages by the NOx correlation utility. This will allow an easy comparison between hourly values recorded after testing is completed to values recorded during the testing, but converted to hourly averages. 18
19 5. At the Main screen for the NOx Correlation testing, be sure to click on the Associate AETB Qualified Individual(s) button in the toolbar or click the link in the AETB Qualified Individual column. This is the person on-site from the stack testing team who they identified as supervising the stack testing. When an AETB Individual has been successfully added or associated with a particular NOx test, the qualified individual s name should now appear on the NOx Correlation Tests tab in the AETB Qualified Individual column. 6. You also must add or associate the PGVP Certificates for the gas cylinders used by the stack testers to run QA checks on their monitors to the NOx Correlation records. This means those certificates must be entered into the Cal Gas Manager feature of StackVision. 7. Failure to associate an AETB individual or all of the gas certificates will trigger a fatal error when the QA file is evaluated in ECMPS. 19
20 8. Use the Retrieve minute data feature to fill in the operating data for each run. 9. Use the Calculate command in the toolbar to calculate the reference mean values for heat input (rounded to 1) and NOx rates rounded to three decimal places. 10. During the Calculate process, the heat input value recorded for each run will be converted to an hourly averages so it can be compared against future hourly averages of heat input. Using the Hourly Heat Input Vs. NOx emission rate curve (see slide 5), StackVision will estimate a corresponding NOx emission rate in lb./mmbtu. 20
21 11. For each of the four operating QA parameters, an average value was calculated for each of the average loads. Establish acceptable parametric ranges for these parameters at each tested load-heat input point. 12. The acceptable ranges should be based upon the turbine/engine manufacturer s recommendations. 13. Alternatively, the operator may use sound engineering judgement and operating experience with the unit to establish these acceptable ranges. 14. The rationale for choosing these parameters and establishing their ranges shall be included in the quality assurance plan for the unit. 21
22 15. For boilers which are using this protocol, the NOx emission rate heat input correlation should be review and possibly redetermined if the excess oxygen level at any heat input rate continuously exceeds by more than 2 percentage points O2 from the boiler excess oxygen level recorded at the same operating heat input rate from the last round of testing, if for one or more successive operating periods totally more than 16 unit operating hours. 16. For turbines and engines, the same holds true. Re-testing might be necessary after continuously exceeding the acceptable range of any of the QA parameters for one or more successive operating periods totaling more than 16 unit operating hours. 22
23 17. Setting up your correlation alarms is very important so you can track the performance of the QA parameters or boiler O2 levels. 18. In the Help area of SV, use the Configure NOx Correlation Alarms guidance to set up the NOXOOS (out-of-spec) and NOXRTEST (when 16 or more consecutive out-of-spec hours have occurred) alarms. 19. The alarms are configured in StackStudio and involve several configuration steps so use the guidance to walk you through the process. 20. Don t forget to setup ProcessNow to generate the hourly NOx emission rates from the hourly heat inputs and to generate the appropriate alarms when operating conditions are out of spec. 23
24 Use your in-house procedure to prepare for these periodic checks and tests. A consistent approach yields consistent and successful results. The data and results associated with these tests are included in the quality assurance file. These records can be generated at any time in SV and evaluated in ECMPS at any time. Don t wait until the end of the quarter to evaluate these results. Questions? Jkonings@envirosys.com or 512/
This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"
This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)" Note to Permit Writer: This condition is for existing engines (commenced
More informationPA RACT 2. Reasonably Available Control Technology. Presented by Suzanne Dibert
PA RACT 2 Reasonably Available Control Technology Presented by Suzanne Dibert Affected Facilities Facilities with potential emissions that exceed 100 tons per year (tpy) for NOx (nitrogen oxide) and 50
More informationDRAFT/PROPOSED. AIR EMISSION PERMIT NO Total Facility Operating Permit Reissuance IS ISSUED TO. Hutchinson Utilities Commission
DRAFT/PROPOSED AIR EMISSION PERMIT NO. 08500034 002 Total Facility Operating Permit Reissuance IS ISSUED TO Hutchinson Utilities Commission Hutchinson Utilities Commission Plant 2 1100 Industrial Boulevard
More informationELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)
RULE 69. ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95) (a) APPLICABILITY (1) Except as provided in Section (b) or otherwise specified
More informationRULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX
RULE 413 - STATIONARY GAS TURBINES Adopted 04-06-95 (Amended 05-01-97, 03-24-05) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION - EMERGENCY STANDBY UNITS 111 EXEMPTION - REMOVAL FROM SERVICE
More informationCAPACITY LIMITED RESOURCES (CLR) / ENERGY LIMITED RESOURCES (ELR)
CAPACITY LIMITED RESOURCES (CLR) / ENERGY LIMITED RESOURCES (ELR) 1 INTRODUCTION A new bidding mechanism is available for qualified generators which allows them to offer generation in the New York market
More informationIndustrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary
Industrial, Commercial and Institutional Boilers at Area Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary Federal Regulation NESHAP, 40 CFR 63, Subpart JJJJJJ Proposed rule published
More informationFor NOx RACT 25+ MMBTU
For NOx RACT 25+ MMBTU 1 - boilers and indirect heat exchangers Today s Presentation feel free to ask questions anytime - 25MMBTU/hr + (burner size) - any fuel - any size facility - non-refinery - without
More informationSP PRO ABB Managed AC Coupling
SP PRO ABB Managed AC Coupling Introduction The SP PRO ABB Managed AC Coupling provides a method of linking the ABB PVI-3.0/3.6/4.2- TL-OUTD and ABB PVI-5000/6000-TL-OUTD string inverters to the SP PRO
More informationRULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions
More informationELD DRIVER GUIDE June 21, 2018
ELD DRIVER GUIDE June 21, 2018 Contents Getting Started with PrePass ELD...4 Enroll in the PrePass ELD Program... 4 For a Carrier Enroll in the ELD Service... 4 For a Driver Get Driver Login Information...
More informationFuel Strategy (Exponential Decay)
By Ten80 Education Fuel Strategy (Exponential Decay) STEM Lesson for TI-Nspire Technology Objective: Collect data and analyze the data using graphs and regressions to understand conservation of energy
More informationAUTHORITY TO CONSTRUCT
AUTHORITY TO CONSTRUCT PERMIT NO: N-6311-9-1 ISSUANCE DATE: 12/17/2008 LEGAL OWNER OR OPERATOR: FISCALINI FARMS & FISCALINI DAIRY MAILING ADDRESS: 7231 COVERT RD MODESTO, CA 95358 LOCATION: 4848 JACKSON
More informationSP PRO KACO Managed AC Coupling
SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load
More informationRegulatory and Permitting Requirements of Stationary Generators In Delaware
Regulatory and Permitting Requirements of Stationary Generators In Delaware Delaware - DNREC Air Quality Management February 7, 2006 Mark A. Prettyman and Guadalupe J. Reynolds Outline Regulation No. 1144
More informationThe Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706
DRAFT Permit: APC-2004/0721-CONSTRUCTION (NSPS) Two Package Boilers The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706 ATTENTION: Andrew Kenner
More informationRICE NESHAP Frequently Asked Questions (FAQ)
RICE NESHAP Frequently Asked Questions (FAQ) What does RICE NESHAP mean? RICE NESHAP is an acronym for Reciprocating Internal Combustion Engines National Emission Standards for Hazardous Air Pollutants.
More informationVALMET IBMACT & Utility MATS. Boiler Tune-ups
VALMET IBMACT & Utility MATS Boiler Tune-ups Boiler Tune-Ups required by the EPA A boiler tune-up refers to many aspects of improving boiler operations. From an emissions perspective, the term boiler tune-up
More informationBoilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97
RULE 425.2 Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97 I. Purpose The purpose of this Rule is to limit oxides of nitrogen (NOx) emissions
More informationAppendix K. Final DOC Conditions
Appendix K Final DOC Conditions Puente Power Project 262 MW (net nominal) GE 7HA.01 Combustion Turbine Generator (CTG) The CTG is simultaneously subject to the emission limits, monitoring requirements,
More informationContents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14
UPDATED February 2, 2018 Contents Getting Started with PrePass ELD...4 Enroll in the PrePass ELD Program... 4 For a Carrier Enroll in the ELD Service... 4 For a Driver Get Driver Login Information... 4
More informationAppendix K. DOC Conditions
Appendix K DOC Conditions Mission Rock Energy Center Five (5) GE LM6000-PG-Sprint Combustion Turbine Generators (CTGs) Total = 275 MW Nominal Each CTG is simultaneously subject to the emission limits,
More informationApplication Note Original Instructions Development of Gas Fuel Control Systems for Dry Low NOx (DLN) Aero-Derivative Gas Turbines
Application Note 83404 Original Instructions Development of Gas Fuel Control Systems for Dry Low NOx (DLN) Aero-Derivative Gas Turbines Woodward reserves the right to update any portion of this publication
More informationCalifornia s Success in Controlling Large Industrial Sources
California s Success in Controlling Large Industrial Sources Endicott House 2006 Symposium Mike Scheible Deputy Executive Officer California Air Resources Board California Environmental Protection Agency
More informationzonarsystems.com Fred Fakkema, Vice President of Compliance, Zonar Ryan Wiese, Compliance Manager, Zonar Ron Cordova, Compliance Manager, Zonar
BE PREPARED FOR A ROADSIDE INSPECTION WITH YOUR AOBRD YOU VE CHOSEN TO DELAY THE ELD MANDATE WITH AN AOBRD HERE S WHAT YOU NEED TO KNOW WHEN IT COMES TO ROADSIDE INSPECTIONS Fred Fakkema, Vice President
More information3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006; Amended December 15, 2011) 1.0 Purpose The purpose
More informationDRAFT/PROPOSED. AIR EMISSION PERMIT NO Total Facility Operating Permit Reissuance IS ISSUED TO. ALLETE Inc dba Minnesota Power Inc
DRAFT/PROPOSED AIR EMISSION PERMIT NO. 13700013 007 Total Facility Operating Permit Reissuance IS ISSUED TO ALLETE Inc dba Minnesota Power Inc Minnesota Power Laskin Energy Center 5699 Colby Lake Road
More informationStreamlining Multiple Applicable Requirements
Streamlining Multiple Applicable Requirements What is Streamlining? 1. Streamlining is the process of determining one set of requirements to be incorporated into the Title V permit from among multiple
More informationAIR EMISSION PERMIT NO IS ISSUED TO INTERSTATE POWER COMPANY
AIR EMISSION PERMIT NO. 09100007-002 IS ISSUED TO INTERSTATE POWER COMPANY INTERSTATE POWER - FOX LAKE STATION County Road 28 Sherburn, Martin County, Minnesota 561710367 The emission units, control equipment
More information9/17/2013 OVERVIEW WHAT RICE UNITS ARE IMPACTED? WHAT IS A RICE UNIT? EXAMPLES OF RICE UNITS WHY IS THE EPA REGULATING RICE?
OVERVIEW Compliance Webinar Reciprocating Internal Combustion Engines RICE September 16, 2013 Jesse Zahn, CHMM Jesse.zahn@hrpassociates.com HRP Associates, Inc. Clifton Park, NY 12065 What is RICE Unit
More informationRULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS
RULE 1146.1. EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (a) Definitions 1. ANNUAL HEAT INPUT means the actual amount
More informationRULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)
RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008) 1.0 Purpose The purpose of this rule is to limit emissions
More informationReal-time Bus Tracking using CrowdSourcing
Real-time Bus Tracking using CrowdSourcing R & D Project Report Submitted in partial fulfillment of the requirements for the degree of Master of Technology by Deepali Mittal 153050016 under the guidance
More informationNATURAL GAS TRANSMISSION
NATURAL GAS TRANSMISSION and PROCESSING APPLICATIONS GUIDANCE This guidance is intended to help applicants prepare applications and certifications with a reduced amount of effort, yielding clearer and
More informationfor the DOT Safety Audit (SA) Compliance Review (CR) or New CSA Streamlined Review (SR)
for the DOT Safety Audit (SA) Compliance Review (CR) or New CSA Streamlined Review (SR) A Quick Reference to DOT Audits and the SAFETY ADUIT GUIDE Management Program Publication UC-101E 2008-2012 WWW.PART380.COM
More informationABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry
ABB MEASUREMENT & ANALYTICS Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry 2 P R E D I C T I V E E M I S S I O N M O N I T O R I N G S Y S T E M S M O N
More informationLEAP: LSC Evaluation and Achievement Program
LEAP: LSC Evaluation and Achievement Program Instructions for the LSC The LEAP online evaluation system is a tool to evaluate achievement and progress of the 59 LSCs. The program evaluates and helps identify
More informationTurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure
TurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure Lab Session #1: System Overview and Operation Purpose: To gain an understanding of the TurboGen TM Gas Turbine Electrical
More informationUsing the NIST Tables for Accumulator Sizing James P. McAdams, PE
5116 Bissonnet #341, Bellaire, TX 77401 Telephone and Fax: (713) 663-6361 jamesmcadams@alumni.rice.edu Using the NIST Tables for Accumulator Sizing James P. McAdams, PE Rev. Date Description Origin. 01
More informationFleetOutlook 2012 Release Notes
FleetOutlook 2012 Release Notes Version 7.1 Last Updated: June 15, 2012 Copyright 2012 Wireless Matrix. All rights reserved. TABLE OF CONTENTS Introduction... 2 Updates to Landmark Features... 2 Defining
More informationDEP7007CC Compliance Certification
Commonwealth of Kentucky Natural Resources & Environmental Protection Cabinet Department for Environmental Protection DIVISION FOR AIR QUALITY DEP7007CC Compliance Certification Division Use Only ID# Permit
More informationDRIVER QUALIFICATION FILE CHECKLIST
DRIVER QUALIFICATION FILE CHECKLIST 1. DRIVER APPLICATION FOR EMPLOYMENT 391.21 2. INQUIRY TO PREVIOUS EMPLOYERS (3 YEARS) 391.23(a)(2) & (c) 3. INQUIRY TO STATE AGENCIES 391.23(a)(1) & (b) 4. MEDICAL
More informationSHAFT ALIGNMENT FORWARD
Service Application Manual SAM Chapter 630-76 Section 24 SHAFT ALIGNMENT FORWARD One of the basic problems of any installation is aligning couplings or shafts. Therefore, this section will endeavor to
More informationMeasurement made easy. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry
Measurement made easy Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry ABB s Predictive Emission Monitoring Systems (PEMS) Experts in emission monitoring ABB
More informationMitsubishi. VFD Manuals
Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi
More informationPaper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE
Paper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE Mercury 50 Field Evaluation and Product Introduction by David Teraji of Solar Turbines Incorporated San Diego, California, USA 1 AUTHORS
More informationSTANDARD OPERATING PROCEDURE (SOP)
Page 1 of 23 FORSYTH COUNTY OFFICE OF ENVIRONMENTAL ASSISTANCE AND PROTECTION STANDARD OPERATING PROCEDURE (SOP) Calibrators Signature Page Section 12 Page 2 of 23 By the signatures below, the Forsyth
More informationFuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House
Fuel Cell Lab Manual Non Conventional Energy Systems Facility Boiler House Department of Mechanical Engineering IIT Kanpur System Description The Nexa system provides up to 1200 watts of unregulated DC
More informationGreenhouse Gas Emissions Model (GEM) User Guide
Greenhouse Gas Emissions Model (GEM) User Guide Greenhouse Gas Emissions Model (GEM) User Guide Assessment and Standards Division Office of Transportation and Air Quality U.S. Environmental Protection
More informationAIR EMISSION PERMIT NO IS ISSUED TO. Cogentrix
AIR EMISSION PERMIT NO. 16300087-004 IS ISSUED TO Cogentrix 9525 105th Street Court South Cottage Grove, Washington County, MN 55016 The emission units, control equipment and emission stacks at the stationary
More informationSTATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98)
RULE 69.3 STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98) (a) APPLICABILITY This rule shall apply to any stationary
More informationBisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -
Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner Users Manual August 5, 2002 A Product By: Bisnet - 1 - DCPP Users Manual Table of Contents CHAPTER 1 PQ 2 4 What is PQ Squared? 4 CHAPTER
More informationRecordkeeping Requirements of the Federal Motor Carrier Safety Regulations
Recordkeeping Requirements of the Federal Motor Carrier Safety Regulations The following table summarizes the recordkeeping requirements of the Federal Motor Carrier Safety Regulations under 49 CFR Parts
More informationAIR EMISSION PERMIT NO Total Facility Oper. Permit - Reissuance IS ISSUED TO. LSPCottage Grove, L.P.
AIR EMISSION PERMIT NO. 16300087-006 Total Facility Oper. Permit - Reissuance IS ISSUED TO LSPCottage Grove, L.P. LSPCOTTAGE GROVE COGENERATION FACILITY 9525 105th Street Court South Cottage Grove, Washington
More informationThe Road to Safety and Compliance Starts with You! ISRI DOT Self-Audit Checklist
The Road to Safety and Compliance Starts with You! ISRI DOT Self-Audit Checklist ISRI DOT Self-Audit Checklist Disclaimer: The material herein is for informational purposes on and is provided on an as-is
More information4.1 Flow Rate Verification and Adjustment
4.1 Flow Rate Verification and Adjustment Once the pressure verification is complete (see Chapter 3), the gas flow rate should be verified. Accurate gas flow through the nozzle is critical for achieving
More informationTS508. QuickStart Guide Registration. This Tool Must Be Registered To Download Free System Updates. 7 8 Captcha code
QuickStart Guide Registration This Tool Must Be Registered To Download Free System Updates Please Note: The following instructions are compatible with any computer with a functional Internet connect. Please
More informatione-track Certified Driver Operating Manual
e-track Certified Driver Operating Manual Copyright 2016 all rights reserved. Page: Table of Contents System Overview 4 Login 5 Certifying Logs 6 Unidentified Driver Records 8 Requested Edits 9 ECM Link
More information2017Compliance Table with methods.xlsx
University of Michigan Renewable Operating Permit Annual Monitoring/Recordkeeping Compliance Table January 1, 2017 through December 31, 2017 Permit Condition Emission Unit: EU-B0260-06 Boiler 6 at Central
More informationTurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure
TurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure Lab Session #1: System Overview and Operation Purpose: To gain an understanding of the TurboGen TM Gas Turbine Electrical
More informationLIFT TRUCK POLICY AND PROGRAM
LIFT TRUCK POLICY AND PROGRAM Table of Contents 1.0 Policy Statement and Program Overview... 4 2.0 Lift Truck Applicable Legislation, Guidelines and Standards... 4 3.0 Forklift Program Requirements...
More informationNO PART OF THIS DOCUMENT MAY BE REPRODUCED WITHOUT PRIOR AGREEMENT AND WRITTEN PERMISSION OF FORD PERFORMANCE PARTS.
Table of Contents Table of Contents... 1 Getting Started... 2 ProCal Flash Tool... 2 Verify Package Contents... 2 Getting to Know the ProCal 3 Software... 3 Prepare Vehicle for Flashing... 7 Download Calibration
More informationENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION
SIC Code: 4911 (Energy Production) DATE: 06/17/2005 Page 1 of 6 DATE APPLICATION RECEIVED: March 31, 2004 (Application # FY04-0427) FACILITY DESCRIPTION Pinetree-Bethlehem (the Permittee) operates a 17.1
More informationFig 1 An illustration of a spring damper unit with a bell crank.
The Damper Workbook Over the last couple of months a number of readers and colleagues have been talking to me and asking questions about damping. In particular what has been cropping up has been the mechanics
More informationAR2000 Rheometer: Instructions
AR2000 Rheometer: Instructions Instrument Setup Note: The order in which the things are powered on is very important! 1. Check to make sure the Smart Swap cable is connected to the machine. 2. Make sure
More informationMotor Tuning Instructions
6/20/12 Motor Tuning Instructions Before you begin tuning: 1. Make sure Pro-Motion is installed. 2. Hook up motor drive, motor, and computer. - Connect motor drive to computer using a USB to Serial Com
More informationZLogs Help. Tablet Applications. Contents. ZLogs Help
Contents ZLogs Home Screen... 3 What s the difference between certifying logs and verifying edits?... 5 What is the self-check and what if it fails?... 6 How do I check and submit my status logs?... 6
More informationWhite Paper Nest Learning Thermostat Efficiency Simulation for the U.K. Nest Labs April 2014
White Paper Nest Learning Thermostat Efficiency Simulation for the U.K. Nest Labs April 2014 Introduction This white paper gives an overview of potential energy savings using the Nest Learning Thermostat
More informationTechnical Support Note
Title: Measuring Emissions from Diesel-Fueled Equipment TSN Number: 09 File:S:\Bridge_Analyzers\Customer_Service_Documentation\Technical_Support_Notes\ 09_Measuring_Emissions_from_Diesel_Fuel_Equipment.docx
More informationAccelerated Life Testing Final Report
Accelerated Life Testing Final Report November 6, 2006 Prepared by the, Project team: Lalith Jayasinghe, Conan O Rourke, Mariana Figueiro Background During the review process of the ENERGY STAR Light Fixture
More information6/1/2011. NSPS and MACT Standards for Combustion Sources at Utility Authorities What happens when a permit has both federal and state regulations?
Presented by Richard M. Cestone, PE, CHMM Birdsall Services Group For NJEWA Conference May 9, 2011 What happens when a permit has both federal and state regulations? 1 Facilities get confused with Federal
More informationQuaSAR Quantitative Statistics
QuaSAR Quantitative Statistics QuaSAR is a program that aids in the Quantitative Statistical Analysis of Reaction Monitoring Experiments. It was designed to quickly and easily convert processed SRM/MRM-MS
More informationUser manual Suppliers evaluation process
User manual Suppliers evaluation process Document status Version Date Main changes Approved to 6 03/10/2014 Add paragraph 3.12 Status of Documents 5 29/09/2014 Indication document types allowed for upload
More informationColumn Name Type Description Year Number Year of the data. Vehicle Miles Traveled
Background Information Each year, Americans drive trillions of miles in their vehicles. Until recently, the number of miles driven increased steadily each year. This drop-off in growth has raised questions
More informationELD Final Rule. What are the next steps to be compliant? Learn about the ELD mandate and how you can meet compliance standards now and in the future
ELD Final Rule What are the next steps to be compliant? Learn about the ELD mandate and how you can meet compliance standards now and in the future Fleetmatics Introductions Paul Kelly Senior Account Manager
More informationABB s supplier qualification process: Achilles and Power &Tech Frequently Asked Questions (FAQs)
ABB s supplier qualification process: Achilles and Power &Tech Frequently Asked Questions (FAQs) June 2013 Overview Why is ABB introducing Achilles? ABB operates in approximately 100 countries. This means
More informationVanpool Regional Administration
Vanpool Regional Administration Contents Introduction... 2 Structure and Layout... 2 Make sure you are in the right application... 3 Vanpool Program Configuration... 3 Lookup... 5 Adding a new van... 6
More informationMerger of the generator interconnection processes of Valley Electric and the ISO;
California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Karen Edson Vice President, Policy & Client Services Date: August 18, 2011 Re: Decision on Valley Electric
More informationECSE-2100 Fields and Waves I Spring Project 1 Beakman s Motor
Names _ and _ Project 1 Beakman s Motor For this project, students should work in groups of two. It is permitted for groups to collaborate, but each group of two must submit a report and build the motor
More informationData Collection Requirements
Data Collection Requirements The information your group submits becomes part of a larger report submitted by CommuteInfo to the National Transit Database and is used for other reporting purposes. The Southwestern
More informationAsia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)
Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11) Office of Naval Research Grant Award Number N0014-12-1-0496 Hydrogen Energy System Simulation Model for Grid Management
More informationIFTA Reconciliation Updated 09/01/2016
Updated 09/01/2016 Table of Contents IFTA Reconciliation IFTA Reconciliation...1 Keys to IFTA Reporting using OneView...1 1. Ensure that fuel records are uploaded into OneView...1 2. Fleet Manager or Fleet
More informationExhaust Gas CO vs A/F Ratio
Title: Tuning an LPG Engine using 2-gas and 4-gas analyzers CO for Air/Fuel Ratio, and HC for Combustion Efficiency- Comparison to Lambda & Combustion Efficiency Number: 18 File:S:\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\18_CO
More informationPARKING LOT QUESTIONS FROM TRAINING PDR REGISTRATION AND FULL MARKET TRAINING MODULES
3/23/10 Trainers Notes: During the Full Market Training on March 18 th, there was some discussion on Slide 10 pertaining to a Demand Response Provider requesting system access on behalf of their Scheduling
More informationSyncUP FLEET. Implementation Guide
SyncUP FLEET Implementation Guide Overview The purpose of this document is to provide all the information necessary for successfully deploying a customer pilot for Hours of Service. This document is split
More informationPerforming ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software
Install a capillary column in the oven of the SRI GC. The ASTM method suggests a 12 meter.32mm id narrow-bore column coupled with a 2.5 meter guard column but permits the use of any column which exhibits
More informationVehicle Online Services
Consultation Document Vehicle Online Services Response from: British Vehicle Rental and Leasing Association River Lodge Badminton Court Amersham BUCKS HP7 0DD Tel: +44 1494 434747 Fax: +44 1494 434499
More informationIgnition Reliability in SGT-750 for Gas Blends at Arctic Conditions. Magnus Persson Combustion Expert / Distributed Generation / Sweden
Ignition Reliability in SGT-750 for Gas Blends at Arctic Conditions Magnus Persson Combustion Expert / Distributed Generation / Sweden siemens.com/power-gas Table of content Objectives of the Project SGT-750
More informationGENERATOR SEAL OIL SYSTEM
GENERATOR SEAL OIL SYSTEM Eskom power utility utilized Flownex SE simulation capabilities to mitigate system shutdowns caused by generator hydrogen (H 2 ) seal ring failures. Engineers modelled the hydrogen
More informationREV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28
REV F2.0 User's Manual Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 Table of Contents INTRODUCTION...4 Starting TOOLBOX Software... 5 MAIN MENU...6 System Setup... 6 Language... 7 Select
More informationDocument ID:
Page 1 of 7 #08-06-04-006K: Information for Identifying Non-GM ECM Calibration Use and Power-up Hardware Detection in Duramax Diesel Engines - Photograph Tech 2 Calibration IDs, Calibration Verification
More informationDynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.
1993-2001 Dynojet Research, Inc. All Rights Reserved.. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software
More informationGREENER SHIPPING SUMMIT 2017
GREENER SHIPPING SUMMIT 2017 EU MRV Regulation Methods of Data Collection of Fuel Differences/Consequences/Evaluation of Methods Antonios Georgantzis 14 November 2017 Eugenides Foundation The EU MRV Timeline
More informationKapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing
Kapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing November, 2013 Table of contents 1. Executive Summary 2. Simple-Cycle LM2500-PH GT operation mode
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the testo 350 portable flue gas analyser Manufactured by: testo AG Testo-Strasse 1 79853 Lenzkirch Germany Has been assessed by Sira Certification
More informationVoting Draft Standard
page 1 of 7 Voting Draft Standard EL-V1M4 Sections 1.7.1 and 1.7.2 March 2013 Description This proposed standard is a modification of EL-V1M4-2009-Rev1.1. The proposed changes are shown through tracking.
More informationFaraday's Law of Induction
Purpose Theory Faraday's Law of Induction a. To investigate the emf induced in a coil that is swinging through a magnetic field; b. To investigate the energy conversion from mechanical energy to electrical
More informationEnvironmental Technology Verification Will This Thing Really Work? Douglas VanOsdell RTI Texas Technology Showcase
Environmental Technology Verification Will This Thing Really Work? Douglas VanOsdell RTI Texas Technology Showcase Overview Introduction What is ETV? Status of Mobile Sources ETV Decisions, Decisions Lots
More informationSigmaSelect Tutorial Application: Rotary table
A rotary table is used to move 10 pound parts through a series of machining operations. The base of the table is an aluminum plate that is 24 in diameter and 0.75 thick. There are six holes in the table
More informationThe Mark V Air/Fuel Controller - Technical Manual -
Neutronics Enterprises Inc. The Mark V Air/Fuel Controller - Technical Manual - For Technical Information contact: Neutronics Enterprises Inc. 11421 West Bernardo Court. San Diego, CA. 92127 (858) 674-2250
More information