1 RULE Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97 I. Purpose The purpose of this Rule is to limit oxides of nitrogen (NOx) emissions from boilers, steam generators, and process heaters to levels consistent with Reasonably Available Control Technology (RACT) to satisfy California Health and Safety Code Section 40918(b) and 1990 Federal Clean Air Act Amendments, Section 182(f). Carbon monoxide emissions are also limited to insure efficient combustion at reduced NOx levels. II. Applicability This Rule shall apply, as specified, to any boiler, steam generator or process heater with rated heat input of 5 million Btu per hour or more and fired with gaseous and/or liquid fuels. III. Definitions A. Annual Heat Input - total heat released (therms) by fuel(s) burned in a unit during a calendar year as determined from higher heating value and cumulative annual fuel(s) usage. B. Boiler or Steam Generator - any external combustion unit fired with liquid and/or gaseous fuel used to produce hot water or steam, but not including gas turbine engine exhaust gas heat recovery systems. C. British Thermal Unit (Btu) - amount of heat required to raise the temperature of one pound of water from 59/F to 60/F at one atmosphere. D. Gaseous Fuel - any fuel existing as gas at standard conditions. E. Heat Input - total heat released (Btu's) by fuel(s) burned in a unit as determined from higher heating value, not including sensible heat of incoming combustion air and fuel(s). F. Higher Heating Value (HHV) - total heat released per mass of fuel burned (Btu's per pound), when fuel and dry air at standard conditions undergo complete combustion and all resulting products are brought to standard conditions. G. Liquid Fuel - any fuel, including distillate and residual oil, existing as liquid at standard conditions

2 H. Natural gas curtailment - loss of natural gas supply due to action of PUC-regulated supplier. For Section V curtailment limit to apply, curtailment must not exceed 168 cumulative hours of operation per calendar year, excluding equipment testing not to exceed 48 hours per calendar year. I. Oxides of Nitrogen (NOx) - total nitrogen oxides (expressed as NO 2 ). J. Process Heater - any external combustion unit fired with liquid and/or gaseous fuel used to transfer heat from combustion gases to liquid process streams. K. Reasonably Available Control Technology (RACT) - lowest emission limitation a particular source is capable of meeting by application of control technology reasonably available considering technological and economic feasibility. L. Rated Heat Input - heat input capacity (Btu's/hr) specified on nameplate of unit or by manufacturer for that model number, or as limited by District permit. M. Standard Conditions - as defined in Rule 102, Subsection DD. N. Therm - 100,000 British thermal units (Btu's). O. Unit - any boiler, steam generator or process heater as defined in this Rule. IV. Exemption This Rule shall not apply to any unit with rated heat input less than 5 million Btu's per hour. V. Requirements A. An owner/operator of any unit subject to this Rule with annual heat input of 90,000 therms or more during one or more of the three preceding years of operation shall comply with following applicable NOx emission limit(s): During Normal Operation During Natural Gas Curtailment Gaseous Fuel 70 ppmv, or 0.09lb/MMBtu ---- Liquid Fuel 115 ppmv, or 0.15 lb/mmbtu 150 ppmv, or 0.19 lb/mmbtu

3 For units subject to this Subsection, carbon monoxide (CO) emissions shall not exceed 400 ppmv. NOx emission limit for any unit fired simultaneously with gaseous and liquid fuels shall be heat input-weighted average of applicable limits. Calculations shall be performed as prescribed in Section VIII. NOx and CO emission limits in ppmv are referenced at dry stack gas conditions, adjusted to 3.00 percent by volume stack gas oxygen in accordance with Section VIII., and averaged over 15 consecutive minutes from no less than 5 data sets, recorded from sampling of no more than 3 minutes. B. An owner/operator of any unit subject to this Rule with annual heat input rate of 90,000 therms or more shall comply, until November 30, 1997, and any unit with annual heat input rate of less than 90,000 therms shall comply with one of the following NOx minimization procedures: 1. Tune each unit at least once per year in accordance with Section IX.; 2. Operate each unit in a manner maintaining stack gas oxygen at no more than 3.00 percent by volume on dry basis; or 3. Operate each unit with an automatic stack gas oxygen trim system set at 3.00 (+0.15) percent by volume on dry basis. C. Monitoring Requirements 1. An owner/operator of any unit simultaneously firing a combination of different fuels shall install and maintain a totalizing mass or volumetric flow rate meter in each fuel line. 2. An owner/operator of any unit utilizing equipment intended to reduce or control NOx shall install and maintain appropriate provisions to monitor operational parameters of unit and/or NOx control system that correlate to NOx emissions. D. Compliance Demonstration 1. An owner/operator of any unit subject to Subsection V.A. shall have the option of complying with either concentration (ppmv) emission limits or heat input basis (lb/mmbtu) emission limits as specified in Subsection V.A. All compliance demonstrations shall be performed using applicable test method(s) specified in Subsection VI.B. and methods selected to demonstrate compliance shall be specified in Emission Control Plan required by Subsection VI.D

4 2. All emission measurements shall be made with unit operating at conditions as close as physically possible to maximum firing rate allowed by KCAPCD Permit to Operate. VI. Administrative Requirements A. Recordkeeping and Reporting 1. An owner/operator of any unit subject to this Rule or limited by permit condition to firing less than 5 million Btu's/hr shall monitor and record HHV and cumulative annual use of each fuel. 2. An owner/operator of any unit operated under natural gas curtailment limit of Subsection V.A. shall monitor and record cumulative annual hours of operation on liquid fuel during curtailment and during testing. 3. An owner/operator of any identical units wishing to limit emissions testing to one unit per group of units pursuant to Subsection VI.C. shall establish correlation of NOx emissions and key operating parameters and keep records of these data for each affected unit. 4. Records shall be maintained for at least two calendar years on site and shall be made readily available to District personnel. 5. Compliance test data and results collected to satisfy Subsection VI.C. shall be submitted to District within 60 days of collection. B. Test Methods 1. Fuel HHV shall be certified by third party fuel supplier or determined by: a. ASTM D or D for liquid fuels; and b. ASTM D or D in conjunction with ASTM D for gaseous fuels. 2. Oxides of nitrogen (ppmv) - EPA Method 7E, or CARB Method Carbon monoxide (ppmv) - EPA Method 10, or CARB Method Stack gas oxygen - EPA Method 3 or 3A, or CARB Method NOx emission rate (heat input basis) - EPA Method 19, or CARB Method 100 and data from fuel flow meter

5 6. Stack gas velocity - EPA Method Stack gas moisture content - EPA Method 4. C. Compliance Testing 1. Any unit subject to requirements of Subsection V.A. shall be tested to determine compliance with applicable requirements not less than once every 12 months. An owner/operator of gaseous fuel-fired units demonstrating compliance for two consecutive years can, if desired, demonstrate compliance once every thirty-six months. 2. An owner/operator of any unit subject to Subsection V.B.2. shall sample and record stack gas oxygen content at least monthly. 3. Test results from an individual unit may be used for other units at the same location provided manufacturer, model number, rated capacity, fuel type, and emission control provisions are identical and key operating parameters such as stack gas oxygen, fuel consumption, etc. are monitored and established to correlate with NOx emissions from unit tested. D. Emission Control Plan An owner/operator of any unit subject to this Rule shall submit to Control Officer an Emission Control Plan including: 1. List of units subject to Rule, including rated heat inputs, anticipated annual heat input, applicable Section V. requirements, and control option chosen, if applicable; 2. Description of actions to be taken to satisfy requirements of Section V. Such plan shall identify actions to be taken to comply, including any type of emissions control to be applied to each unit and construction schedule, or shall include test results to demonstrate unit already complies with applicable requirements; and 3. Specification of proposed test methods. VII. Compliance Schedule A. An owner/operator of any unit subject to Section V. shall comply with following schedule: 1. By March 1, 1995, submit to Control Officer an Emission Control Plan pursuant to Subsection VI.D., and a complete application for Authority to Construct emission control equipment, if necessary;

6 2. By May 31, 1995 demonstrate compliance with Subsection V.B.; and 3. By November 30, 1997 demonstrate full compliance with all additional and applicable provisions of this Rule. B. An owner/operator of any unit becoming subject to requirements of Subsection V.A. by exceeding the annual heat input exemption threshold shall comply with following increments of progress: 1. On or before December 31st of calendar year immediately following year annual heat input threshold was exceeded, submit an Emission Control Plan containing information prescribed in Subsection VI.D.; and 2. No later than three calendar years following submission of Emission Control Plan, demonstrate final compliance with all applicable standards and requirements of this Rule. VIII. Calculations A. All ppmv emission limits specified in Section V.A. are referenced at dry stack gas conditions and 3.00 percent by volume stack gas oxygen. Emission concentrations shall be corrected to 3.00 percent oxygen as follows: [ppmvnox] corrected = 17.95% x [ppmvnox] measured 20.95%-[%O 2 ] measured [ppmco] corrected = 17.95% x [ppmco] measured 20.95%-[%O 2 ] measured B. All lb/mmbtu NOx emission rates shall be calculated as pounds of nitrogen dioxide per million Btu's of heat input (HHV). C. Heat input-weighted average NOx emission limit for combination of natural gas and liquid fuel shall be calculated as follows: NOx Emission Limit = (70ppmv x X) + (115ppmv x Y) X + Y Where X = heat input from gaseous fuel and Y = heat input from liquid fuel

7 IX. NOx Minimization Tuning Procedures A. Purpose The purpose of these procedures is to provide a reasonable, cost-effective method to minimize NOx emissions from smaller, or low-fire/low use-rate combustion units subject to this Rule. These procedures not only minimize NOx emissions, but also result in reduced operating costs. B. Equipment Tuning Procedure 1 for Mechanical Draft Boilers, Steam Generators, and Process Heaters Nothing in this Tuning Procedure shall be construed to require any act or omission that would result in unsafe conditions or would be in violation of any regulation or requirement established by Factory Mutual, Industrial Risk Insurers, National Fire Prevention Association, California Department of Industrial Relations (Occupational Safety and Health Division), Federal Occupational Safety and Health Administration, or other relevant regulations and requirements. 1. Operate unit at firing rate most typical of normal operation. If unit experiences significant load variations during normal operation, operate at its average firing rate. 2. At this firing rate, record stack gas temperature, oxygen concentration, and CO concentration (for gaseous fuels) or smoke spot number 2 (for liquid fuels), and observe flame conditions after unit operation stabilizes at firing rate selected. If excess oxygen in the stack gas is at lower end of range of typical minimum values 3 ; and if CO emissions are low and there is no smoke, unit is probably operating at near optimum efficiency - at this particular firing rate. However, complete remaining portion of this procedure to determine whether still lower oxygen levels are practical. 3. Increase combustion air flow to unit until stack gas oxygen levels increase by one to two percent over level measured in Step 2. As in Step 2, record stack gas temperature, CO concentration (for gaseous fuels) or smoke spot number (for liquid fuels), and observe flame conditions for these higher oxygen levels after unit operation stabilizes. 1. This tuning procedure is based on a tune-up procedure developed by KVB, Inc. for U.S. EPA. 2. The smoke-spot number can be determined with ASTM Test Method D-2156 or with the Bacharach method. 3. Typical minimum oxygen levels for boilers at high firing rates are: For natural gas: 0.5% to 3% and For liquid fuels: 2% to 4%

8 4. Decrease combustion air flow until stack gas oxygen concentration is at level measured in Step 2. From this level gradually reduce combustion air flow, in small increments. After each increment, record stack gas temperature, oxygen concentration, CO concentration (for gaseous fuels) and smoke-spot number (for liquid fuels). Also, observe flame and record any changes in its condition. 5. Continue to reduce combustion air flow stepwise, until one of these limits is reached: a. Unacceptable flame conditions- such as flame impingement on furnace walls or burner parts, excessive flame carryover, or flame instability, b. Stack gas CO concentrations greater than 400 ppm, c. Smoking at the stack, or d. Equipment-related limitations such as low windbox/furnace pressure differential, built in air-flow limits, etc. 6. Develop O 2 /CO curve (for gaseous fuels) or O 2 /smoke curve (for liquid fuels) similar to those shown in Figures 1 and 2 on Page using excess oxygen and CO or smoke-spot number data obtained at each combustion air flow setting. 7. From curves prepared in Step 6, find stack gas oxygen levels where CO emissions or smoke-spot number equal following values: Fuel Measurement Value Gaseous CO Emissions 400 ppm #1 and #2 Oils #4 Oil smoke-spot number smoke-spot number number 1 number 2 #5 Oil smoke-spot number number 3 Other Oils smoke-spot number number 4 Above conditions are referred to as CO or smoke thresholds, or as minimum excess oxygen levels. Compare this minimum value of excess oxygen to expected value provided by combustion unit manufacturer. If minimum level found is substantially higher than value provided by combustion unit manufacturer, burner adjustments can probably be made to improve fuel and air mix, thereby allowing operations with less air

9 8. Add 0.5 to 2.0 percent to minimum excess oxygen level determined in Step 7 and reset burner controls to operate automatically at this higher stack gas oxygen level. This margin above minimum oxygen level accounts for fuel variations, variations in atmospheric conditions, load changes, and nonrepeatability or "play" in automatic controls. 9. If load of unit varies significantly during normal operation, repeat Steps 1-8 for firing rates that represent upper and lower limits of range of the load. Because control adjustments at one firing rate may affect conditions at other firing rates, it may not be possible to establish optimum excess oxygen level at all firing rates. If this is the case, choose burner control settings that give best performance over range of firing rates. If one firing rate predominates, setting should optimize conditions at that rate. 10. Verify that new settings can accommodate sudden load changes that may occur in daily operation without adverse effects. Do this by increasing and decreasing load rapidly while observing flame and stack. If any of conditions in Step 5 result, reset combustion control to provide slightly higher level of excess oxygen at affected firing rates. Next verify these new settings in a similar fashion. Then make sure that final control settings are recorded at steady-state operating conditions for future reference. C. Equipment Tuning Procedure 1 for Natural and Induced-Draft Boilers, Steam Generators, and Process Heaters Nothing in this Tuning Procedure shall be construed to require any act or omission that would result in unsafe conditions or would be in violation of any regulation or requirement established by Factory Mutual, Industrial Risk Insurers, National Fire Prevention Association, the California Department of Industrial Relations (Occupational Safety and Health Division), the Federal Occupational Safety and Health Administration, or other relevant regulations and requirements. 1. Preliminary analysis a. Check operating pressure or temperature. Operate unit at lowest acceptable pressure or temperature that will satisfy load demand. Determine pressure or temperature that will be used as basis for comparative combustion analysis before and after tuneup. b. Check operating hours. Plan workload so that unit operates only the minimum hours and days necessary to perform work required. This tuning procedure is based on a tune-up procedure developed by Parker Boiler for South Coast AQMD

10 c. Check air supply. Area of air supply openings must be in compliance with applicable codes and regulations. Air openings must be kept wide open when burner is firing and clean from restriction to flow. d. Check vent. Check to be sure vent is in good condition, sized properly and with no obstructions. e. Perform combustion analysis. Perform an "as is" flue gas analysis (O 2, CO, CO 2, etc.) at high and low fire, if possible. In addition to data obtained from combustion analysis, also record following: 1) Inlet fuel pressure at burner (at high and low fire), 2) Draft at inlet of draft hood or barometric damper at high, medium, and low settings, if applicable, 3) Steam pressure, water temperature, or process fluid pressure or temperature entering and leaving unit, and 4) Unit rate, if meter is available. With above conditions recorded, make following checks and corrective actions as necessary. 2. Checks and Corrections a. Check burner condition. Clean burners and burner orifices thoroughly. To clean burners effectively all burners must be removed, blown out with high pressure air and checked for obstructions. All accumulated sediment, dirt, and carbon must be removed. Check for smooth lighting and even flame. Also, ensure that fuel filters and moisture traps are in place, clean, and operating properly, to prevent plugging of gas orifices. Confirm proper location and orientation of burner diffuser spuds, gas canes, etc. Look for any burned-off or missing burner parts, and replace as needed. b. Check for clean boiler, steam generator, or process heater tubes and heat transfer surfaces. Clean tube surfaces, remove scale and soot, assure proper fluid flow, and flue gas flow. c. Check water treatment and blowdown program. Employ timely flushing and periodic blowdown to eliminate sediment and scale build-up in heat exchange tubes. d. Check for steam hot water or process fluid leaks. Repair all leaks immediately. Be sure there are no leaks through the blow-off drains, safety valve, by-pass lines or at the feed pump, if used

11 3. Safety Checks a. Test primary and secondary low water level controls. b. Check operating and limit pressure and temperature controls. c. Check safety valve pressure and capacity to meet boiler, steam generator, or process heater requirements. d. Check limit safety control and spill switch. 4. Adjustments While taking combustion readings with unit at operating temperature and at high fire perform checks and adjustments as follows: a. Adjust unit to fire at rated capacity. Record fuel manifold pressure. b. Adjust draft and/or fuel pressure to obtain efficient, clean combustion at both high, medium and low fire. Carbon monoxide value should always be below 400 ppm at 3% O 2. If CO is high make necessary adjustment such as increasing draft. Check to ensure burner light offs are smooth and safe. A reduced fuel pressure test at both high and low fire should be conducted in accordance with manufacturer's instructions and maintenance manuals. c. Check and adjust operation of modulation controller. Insure proper, efficient and clean combustion through range of firing rates. When above adjustments and corrections have been made, record all data. 5. Final Test Perform final combustion analysis with unit at operating temperature and at high, medium, and low fire, whenever possible. In addition to data from combustion analysis, also check and record: a. Fuel pressure at burner (high, medium, and low settings, if applicable). b. Draft at inlet or above draft hood or barometric damper (high, medium, and low settings, if applicable). c. Steam pressure or water temperature entering and leaving unit. d. Unit rate, if fuel meter is available

12 When above checks and adjustments have been made, record data and attach combustion analysis data to boiler, steam generator, or process heater records indicating name and signature of person, title, company name, company address and date tuneup was performed

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.15.1 - BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) A. Applicability The provisions of this

More information

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS RULE 1146.1. EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (a) Definitions 1. ANNUAL HEAT INPUT means the actual amount

More information

(2) ANNUAL HEAT INPUT means the actual amount of heat released by fuels burned in a unit during a calendar year.

(2) ANNUAL HEAT INPUT means the actual amount of heat released by fuels burned in a unit during a calendar year. 1 of 11 8/21/2012 10:19 AM SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1146 - EMISSIONS OF OXIDES OF NITROGEN FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS

More information

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12, 6/23/15)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12, 6/23/15) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.15.1 - BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12, 6/23/15) A. Applicability The provisions

More information

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions

More information

August 23,

August 23, RULE 411, NO X FROM BOILERS, PROCESS HEATERS AND STEAM GENERATORS Adopted 02-02-95 (Amended 11/7/96, 01/09/97, 7/22/99, 10/27/05, 8/23/07) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION

More information

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions). RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006; Amended December 15, 2011) 1.0 Purpose The purpose

More information

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008) RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008) 1.0 Purpose The purpose of this rule is to limit emissions

More information

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95) RULE 69. ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95) (a) APPLICABILITY (1) Except as provided in Section (b) or otherwise specified

More information

RULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016)

RULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.34 NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016) A. Purpose and Applicability The purpose of this rule is to reduce emissions of oxides

More information

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX RULE 413 - STATIONARY GAS TURBINES Adopted 04-06-95 (Amended 05-01-97, 03-24-05) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION - EMERGENCY STANDBY UNITS 111 EXEMPTION - REMOVAL FROM SERVICE

More information

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68.

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68. RULE 69.4. STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted 9/27/94; Rev. Effective11/15/00; Rev. Effective 7/30/03) (a) APPLICABILITY (1) Except

More information

3. Operation of any applicable boiler on any amount of fuel oil shall be prohibited, except as provided in Subsection C.3.

3. Operation of any applicable boiler on any amount of fuel oil shall be prohibited, except as provided in Subsection C.3. VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 59 - ELECTRICAL POWER GENERATING EQUIPMENT - OXIDES OF NITROGEN EMISSIONS (Adopted 10/6/69, Revised 5/23/72, 7/18/72, 10/31/72, 8/14/79, 12/7/82, 6/4/91,

More information

RULE 412 STATIONARY INTERNAL COMBUSTION ENGINES LOCATED AT MAJOR STATIONARY SOURCES OF NO X Adopted INDEX

RULE 412 STATIONARY INTERNAL COMBUSTION ENGINES LOCATED AT MAJOR STATIONARY SOURCES OF NO X Adopted INDEX RULE 412 STATIONARY INTERNAL COMBUSTION ENGINES LOCATED AT MAJOR STATIONARY SOURCES OF NO X Adopted 06-01-95 INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION, EMERGENCY STANDBY 111 EXEMPTION,

More information

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary Industrial, Commercial and Institutional Boilers at Area Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary Federal Regulation NESHAP, 40 CFR 63, Subpart JJJJJJ Proposed rule published

More information

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants. RULE 2530 FEDERALLY ENFORCEABLE POTENTIAL TO EMIT (Adopted June 15, 1995; Amended April 25, 2002; Amended December 18, 2008, but not in effect until June 10, 2010) 1.0 Purpose The purpose of this rule

More information

STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98)

STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98) RULE 69.3 STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98) (a) APPLICABILITY This rule shall apply to any stationary

More information

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus AIR QUALITY PERMIT Permit No. Effective Date February 11, 2016 In accordance with the provisions of the Georgia Air Quality Act, O.C.G.A. Section 12-9-1, et seq and the Rules, Chapter 391-3-1, adopted

More information

402 LOSS OF EXEMPTION LOW FUEL USAGE 4032 SOURCE TESTING FREQUENCY 4043 SOURCE TESTING PROTOCOL

402 LOSS OF EXEMPTION LOW FUEL USAGE 4032 SOURCE TESTING FREQUENCY 4043 SOURCE TESTING PROTOCOL Attachment 6: Proposed Rule 419, Underline/Strikeout Version RULE 419 NOx FROM MISCELLANEOUS COMBUSTION UNITS Adopted 07-26-18 (Amended XX-XX-18) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 103 SEVERABILITY

More information

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT DATE: 3/1/10, updated 5/5/10 TO: Interested Parties SUBJECT: Frequently asked questions regarding compliance with Rule 4320, Advanced Emission Reduction

More information

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the 15A NCAC 02D.1206 HOSPITAL, MEDICAL, AND INFECTIOUS WASTE INCINERATORS (a) Applicability. This Rule applies to any hospital, medical, and infectious waste incinerator (HMIWI), except: (1) any HMIWI required

More information

State of New Jersey. General Permit (GP-009A)

State of New Jersey. General Permit (GP-009A) 03/21/2013 State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-009A) For Boiler(s) and Indirect Fired Process Heater(s) Each Greater Than or Equal to 10

More information

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks Approved By: Signed Seyed Sadredin Director of Permit Services

More information

Part 70 Operating Permit Amendment

Part 70 Operating Permit Amendment Part 70 Operating Permit Amendment Effective Date: February 18, 2016 Facility Name: Scherer Steam-Electric Generating Plant Facility Address 10986 Highway 87 Juliette, Georgia 31046, Monroe County Mailing

More information

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:

More information

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS Adopted 2-5-75 (Amended 9-15-75, 6-1-76, 8-3-77, 9-29-87, 12-17-91, 2-2-95, 4-3-97, 09-26-02, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY

More information

Tune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers.

Tune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers. Tune-up Information National Emission Standards for Hazardous Air Pollutants for Area Sources: Industrial, Commercial, and Institutional Boilers 40 CFR Part 63 Subpart JJJJJJ Who must conduct a tune-up

More information

AUTHORITY TO CONSTRUCT

AUTHORITY TO CONSTRUCT AUTHORITY TO CONSTRUCT PERMIT NO: N-6311-9-1 ISSUANCE DATE: 12/17/2008 LEGAL OWNER OR OPERATOR: FISCALINI FARMS & FISCALINI DAIRY MAILING ADDRESS: 7231 COVERT RD MODESTO, CA 95358 LOCATION: 4848 JACKSON

More information

Appendix K. Final DOC Conditions

Appendix K. Final DOC Conditions Appendix K Final DOC Conditions Puente Power Project 262 MW (net nominal) GE 7HA.01 Combustion Turbine Generator (CTG) The CTG is simultaneously subject to the emission limits, monitoring requirements,

More information

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks. Rule 215 Phase II Vapor Recovery System Requirements Part 1.0 General 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks. 1.2 Applicability

More information

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids. RULE 4624 TRANSFER OF ORGANIC LIQUID (Adopted April 11, 1991; Amended September 19, 1991; Amended May 21, 1992; Amended December 17, 1992; Amended December 20, 2007) 1.0 Purpose The purpose of this rule

More information

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706 DRAFT Permit: APC-2004/0721-CONSTRUCTION (NSPS) Two Package Boilers The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706 ATTENTION: Andrew Kenner

More information

(Adopted December 5, 2008)(Amended September 9, 2011)(Amended July 7, 2017) NOx REDUCTIONS FROM MISCELLANEOUS SOURCES

(Adopted December 5, 2008)(Amended September 9, 2011)(Amended July 7, 2017) NOx REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted December 5, 2008)(Amended September 9, 2011)(Amended July 7, 2017) RULE 1147 NOx REDUCTIONS FROM MISCELLANEOUS SOURCES (a) (b) Purpose and Applicability The purpose of this rule is to reduce nitrogen

More information

RULE 4702 INTERNAL COMBUSTION ENGINES PHASE 2 (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007)

RULE 4702 INTERNAL COMBUSTION ENGINES PHASE 2 (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007) RULE 4702 INTERNAL COMBUSTION ENGINES PHASE 2 (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007) 1.0 Purpose The purpose of this rule is to limit the emissions

More information

ARTICLE AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES

ARTICLE AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES TABLE OF CONTENTS ARTICLE 2.0000 AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES Section 2.1400 Nitrogen Oxides 2.1401 Definitions... 214-01 2.1402 Applicability... 214-04 2.1403 Compliance Schedules...

More information

San Joaquin Valley Unified Air Pollution Control District Permit Services Division

San Joaquin Valley Unified Air Pollution Control District Permit Services Division San Joaquin Valley Unified Air Pollution Control District Permit Services Division Organic Liquid Storage Tanks Cleaning Requirements Approved By: Date: 2/20/08 David Warner Director of Permit

More information

Appendix K. DOC Conditions

Appendix K. DOC Conditions Appendix K DOC Conditions Mission Rock Energy Center Five (5) GE LM6000-PG-Sprint Combustion Turbine Generators (CTGs) Total = 275 MW Nominal Each CTG is simultaneously subject to the emission limits,

More information

AIR QUALITY PERMIT. Permit No S Effective Date May 26, 2015

AIR QUALITY PERMIT. Permit No S Effective Date May 26, 2015 AIR QUALITY PERMIT Permit No. Effective Date May 26, 2015 In accordance with the provisions of the Georgia Air Quality Act, O.C.G.A. Section 12-9-1, et seq and the Rules, Chapter 391-3-1, adopted pursuant

More information

SECTION.1400 NITROGEN OXIDES

SECTION.1400 NITROGEN OXIDES SECTION.1400 NITROGEN OXIDES 15A NCAC 02D.1401 DEFINITIONS (a) For the purpose of this Section, the definitions at G.S 143-212 and G.S. 143-213, and 15A NCAC 02D.0101 shall apply, and in addition the following

More information

2017Compliance Table with methods.xlsx

2017Compliance Table with methods.xlsx University of Michigan Renewable Operating Permit Annual Monitoring/Recordkeeping Compliance Table January 1, 2017 through December 31, 2017 Permit Condition Emission Unit: EU-B0260-06 Boiler 6 at Central

More information

APPENDIX D. REGULATIONS (excerpts) ON 24-HOUR EMISSION LIMITS: MARYLAND DEPARTMENT OF THE ENVIRONMENT

APPENDIX D. REGULATIONS (excerpts) ON 24-HOUR EMISSION LIMITS: MARYLAND DEPARTMENT OF THE ENVIRONMENT APPENDIX D APPENDIX D REGULATIONS (excerpts) ON 24-HOUR EMISSION LIMITS: MARYLAND DEPARTMENT OF THE ENVIRONMENT DELAWARE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL CONTROL NEW JERSEY STATE DEPARTMENT

More information

State of New Jersey Department of Environmental Protection Division of Air Quality. General Operating Permit (GOP-007) Boiler or Heater

State of New Jersey Department of Environmental Protection Division of Air Quality. General Operating Permit (GOP-007) Boiler or Heater 11/21/2016 State of New Jersey Department of Environmental Protection Division of Air Quality General Operating Permit (GOP-007) Boiler or Heater Greater than or equal to 1 MMBTU/hr and less than 5 MMBTU/hr

More information

ICAPCD RULE APPENDIX C

ICAPCD RULE APPENDIX C There is not a federal policy that establishes maximum cost effectiveness values for NOx RACT. The San Joaquin Valley APCD uses a BARCT threshold of $9,700.00 (California Air Resources Board (CARB), Report

More information

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County) AIR QUALITY PERMIT Permit No. Effective Date April 11, 2016 In accordance with the provisions of the Georgia Air Quality Act, O.C.G.A. Section 12-9-1, et seq and the Rules, Chapter 391-3-1, adopted pursuant

More information

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM June 17, 2004 SUBJECT: Review of Application Title V Operating Permit Bellefield Boiler Plant Boundary Street Pittsburgh, PA 15213 RE: Operating Permit

More information

Fuel Oil Conversions. Association of Energy Engineers (AEE) September 20, 2011

Fuel Oil Conversions. Association of Energy Engineers (AEE) September 20, 2011 Fuel Oil Conversions Association of Energy Engineers (AEE) September 20, 2011 Overview Our Plan to Improve Air Quality 1. Heating Oil Regulations 2. Accelerating Conversions 3. Streamlining the Process

More information

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC 2011 Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC Ohio EPA, Division of Air Pollution Control 1/1/2011 Page 2

More information

State of New Jersey. Department of Environmental Protection Division of Air Quality

State of New Jersey. Department of Environmental Protection Division of Air Quality GOP-006 State of New Jersey Department of Environmental Protection Division of Air Quality General Operating Permit (GOP-006) Combined Heat and Power Stationary Spark Ignition Reciprocating Engine(s) less

More information

This rule applies to any internal combustion engine rated at 25 brake horsepower or greater.

This rule applies to any internal combustion engine rated at 25 brake horsepower or greater. RULE 4702 INTERNAL COMBUSTION ENGINES (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007; Amended August 18, 2011; Amended November 14, 2013) 1.0 Purpose

More information

Permit Holder. Permitted Equipment

Permit Holder. Permitted Equipment Air Quality Registration Stationary Spark Ignition Internal Combustion Engine (Less than 400 Brake Horsepower) Permit No. Project No. Description Date Testing No Plant Number: Under the Direction of the

More information

VALMET IBMACT & Utility MATS. Boiler Tune-ups

VALMET IBMACT & Utility MATS. Boiler Tune-ups VALMET IBMACT & Utility MATS Boiler Tune-ups Boiler Tune-Ups required by the EPA A boiler tune-up refers to many aspects of improving boiler operations. From an emissions perspective, the term boiler tune-up

More information

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994. VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 70 - STORAGE AND TRANSFER OF GASOLINE (Adopted 6/25/74, Revised 9/16/75, 4/13/76, 7/6/76, 3/8/77, 6/14/77, 3/27/79, 12/2/80, 7/5/83, 11/29/88, 5/4/93,

More information

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) RULE 346. LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) A. Applicability The provisions of this rule shall apply to the transfer of organic liquids into an organic liquid

More information

Facility Name: BASF Corporation Attapulgus Operations City: Attapulgus County: Decatur AIRS #: Application #: 22788

Facility Name: BASF Corporation Attapulgus Operations City: Attapulgus County: Decatur AIRS #: Application #: 22788 Facility Name: BASF Corporation Attapulgus Operations City: Attapulgus County: Decatur AIRS #: 04-13-08700037 Application #: 22788 Date SIP Application Received: August 11, 2014 Date Title V Application

More information

COST EFFECTIVENESS EVALUATION. A. Selective Catalytic Reduction System

COST EFFECTIVENESS EVALUATION. A. Selective Catalytic Reduction System was installed with a Selective Catalytic Reduction (SCR) and is able to comply with a NOx emission limit of 9 ppmv when operating with natural gas and 13 ppmv when operating under diesel fuel. In addition,

More information

REGULATION 6 PARTICULATE MATTER RULE 1 GENERAL REQUIREMENTS INDEX

REGULATION 6 PARTICULATE MATTER RULE 1 GENERAL REQUIREMENTS INDEX 6-1-100 GENERAL REGULATION 6 PARTICULATE MATTER RULE 1 GENERAL REQUIREMENTS INDEX 6-1-101 Description 6-1-102 Applicability of General Provisions: 6-1-110 Exemptions for Activities Subject to Other Rules

More information

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. May 1, 2015 PERMIT TO INSTALL 4-13B. ISSUED TO Zoetis LLC

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. May 1, 2015 PERMIT TO INSTALL 4-13B. ISSUED TO Zoetis LLC MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION May 1, 2015 PERMIT TO INSTALL 4-13B ISSUED TO Zoetis LLC LOCATED AT 306 Pitcher Street Kalamazoo, Michigan IN THE COUNTY OF Kalamazoo STATE

More information

AUTHORITY TO CONSTRUCT

AUTHORITY TO CONSTRUCT AUTHORITY TO CONSTRUCT PERMIT NO: S-7658-1-0 ISSUANCE DATE: 10/30/2009 LEGAL OWNER OR OPERATOR: ABEC BIDART-STOCKDALE LLC MAILING ADDRESS: C/O CALIFORNIA BIOENERGY LLC 2828 ROUTH STREET SUITE 500 DALLAS,

More information

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL 2016 TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL This document was prepared by the Renewable Fuels Association (RFA). The information, though believed to be accurate at the time of publication,

More information

Full Compliance Evaluation Report Off-Site Report

Full Compliance Evaluation Report Off-Site Report STATE OF NEW HAMPSHIRE DEPARTMENT OF ENVIRONMENTAL SERVICES AIR RESOURCES DIVISION Full Compliance Evaluation Report Off-Site Report CONCORD STEAM CORPORATION 105 ½ PLEASANT STREET CONCORD, NH 03302-1377

More information

ACTUAL CYCLE. Actual engine cycle

ACTUAL CYCLE. Actual engine cycle 1 ACTUAL CYCLE Actual engine cycle Introduction 2 Ideal Gas Cycle (Air Standard Cycle) Idealized processes Idealize working Fluid Fuel-Air Cycle Idealized Processes Accurate Working Fluid Model Actual

More information

DEP7007CC Compliance Certification

DEP7007CC Compliance Certification Commonwealth of Kentucky Natural Resources & Environmental Protection Cabinet Department for Environmental Protection DIVISION FOR AIR QUALITY DEP7007CC Compliance Certification Division Use Only ID# Permit

More information

MAJOR SOURCE OPERATING PERMIT

MAJOR SOURCE OPERATING PERMIT MAJOR SOURCE OPERATING PERMIT Permitee: Facility Name: Facility No.: Location: INTERNATIONAL PAPER CO. INTERNATIONAL PAPER RIVERDALE MILL 104-0003 SELMA, ALABAMA In accordance with and subject to the provisions

More information

SWCAA. Southwest Clean Air Agency. October 10, Troy Lomax Longview School District h A venue Longview, WA 98632

SWCAA. Southwest Clean Air Agency. October 10, Troy Lomax Longview School District h A venue Longview, WA 98632 A SWCAA Southwest Clean Air Agency 85 NE 99th Street, Suite 294 Vancouver, WA 98682 (360) 5743058 www.swcleanair.org October 0, 208 Troy Lomax Longview School District 2080 3 8 h A venue Longview, WA 98632

More information

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION SIC Code: 4911 (Energy Production) DATE: 06/17/2005 Page 1 of 6 DATE APPLICATION RECEIVED: March 31, 2004 (Application # FY04-0427) FACILITY DESCRIPTION Pinetree-Bethlehem (the Permittee) operates a 17.1

More information

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS: COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT AIR POLLUTION CONTROL DIVISION TELEPHONE: (303) 692-3150 CONSTRUCTION PERMIT PERMIT NO: 11PB859 DATE ISSUED: JULY 5, 2005 INITIAL APPROVAL Modification

More information

~ SWCAA. ~awfxm~ Paul T. Mairose Chief Engineer

~ SWCAA. ~awfxm~ Paul T. Mairose Chief Engineer ~ SWCAA Southwest Clean Air Agency 11815 NE 99th Street, Suite 1294 Vancouver, WA 98682 (360) 574-3058 www.swcleanair.org December 22, 2017 AJ Panter Vancouver School District No. 37 6014 NW Fruit Valley

More information

RULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996)

RULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996) RULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996) 1.0 Purpose The purpose of this rule is to provide an administrative mechanism, and establish standards for registration

More information

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

This is a new permit condition titled, 2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP) This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)" Note to Permit Writer: This condition is for existing engines (commenced

More information

General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels

General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels GP-005B State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels This general permit allows for the construction,

More information

REGISTRATION OF SPECIFIED EQUIPMENT (Adopted 5/21/97; Rev. Effective 11/15/00) (1) This rule applies to the following emission units:

REGISTRATION OF SPECIFIED EQUIPMENT (Adopted 5/21/97; Rev. Effective 11/15/00) (1) This rule applies to the following emission units: RULE 12. REGISTRATION OF SPECIFIED EQUIPMENT (Adopted 5/21/97; Rev. Effective 11/15/00) (a) APPLICABILITY (1) This rule applies to the following emission units: Existing internal combustion emergency standby

More information

PERMIT APPLICATION REVIEW SUMMARY

PERMIT APPLICATION REVIEW SUMMARY PERMIT APPLICATION REVIEW SUMMARY New Hampshire Department of Environmental Services Air Resources Division P.O. Box 95, 29 Hazen Drive Concord, NH 03302-0095 Phone: 603-271-1370 Fax: 603-271-7053 AFS

More information

State of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-017A) For

State of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-017A) For State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-017A) For Boiler(s) and/or Heater(s) Each Less Than 5 MMBTU/hr This general permit allows for the construction,

More information

Board Administration and Regulatory Coordination Unit. Division 3. Air Resources Board

Board Administration and Regulatory Coordination Unit. Division 3. Air Resources Board 2423. Exhaust Emission Standards and Test Procedures--Heavy-Duty Off-Road Diesel Cycle Engines. (a) This section shall be applicable to new heavy-duty off-road compression-ignition engines, produced on

More information

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00) RULE 61.2. TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00) (a) APPLICABILITY Except as otherwise provided in Section (b), this rule is applicable to the

More information

PERMIT TO INSTALL. Table of Contents

PERMIT TO INSTALL. Table of Contents Permit No. 118-18 Page 1 of 23 PERMIT TO INSTALL Table of Contents COMMON ACRONYMS... 2 POLLUTANT / MEASUREMENT ABBREVIATIONS... 3 GENERAL CONDITIONS... 4 EMISSION UNIT SPECIAL CONDITIONS... 6 EMISSION

More information

RULES PUBLICATION NO. 98/P

RULES PUBLICATION NO. 98/P RULES PUBLICATION NO. 98/P GUIDELINES REGARDING THE REQUIREMENTS FOR MARINE DIESEL ENGINES FITTED WITH NO X SELECTIVE CATALYTIC REDUCTION (SCR) SYSTEMS 2018 January Publications P (Additional Rule Requirements)

More information

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08)

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08) RULE 61.4.1 TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08) (a) APPLICABILITY Except as otherwise provided in Section (b), this

More information

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015 Georgia Department of Natural Resources Environmental Protection Division Air Protection Branch 4244 International Parkway Suite 120 Atlanta Georgia 30354 404/363-7000 Fax: 404/363-7100 Judson H. Turner,

More information

Electrical Power Generator Use and Procurement Guidance

Electrical Power Generator Use and Procurement Guidance Electrical Power Generator Use and Procurement Guidance For compliance with applicable air emission control regulations December 2016 Prepared by: Syracuse University Environmental Health & Safety Services

More information

Air Individual Permit Permit Limits to Avoid NSR

Air Individual Permit Permit Limits to Avoid NSR Air Individual Permit Permit Limits to Avoid NSR 13900128-001 Permittee: Facility name: Shakopee Distributed Generation Shakopee Distributed Generation Vierling Drive E Shakopee, Minnesota 55379 Scott

More information

Multi-Sector Air Pollutants Regulations (MSAPR) May 2017

Multi-Sector Air Pollutants Regulations (MSAPR) May 2017 Multi-Sector Air Pollutants Regulations (MSAPR) May 2017 Purpose The Multi-Sector Air Pollutants Regulations (MSAPR) came into force on June 17, 2016 This presentation will provide an overview of: MSAPR

More information

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1 6 March 2007 AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS FOR PERIODICAL TECHNICAL INSPECTIONS OF WHEELED VEHICLES AND THE RECIPROCAL RECOGNITION OF SUCH INSPECTIONS done at Vienna on 13 November

More information

Facility Name: Georgia-Pacific Consumer Products LP Savannah River Mill City: Rincon County: Effingham AIRS #: Application #: 40890

Facility Name: Georgia-Pacific Consumer Products LP Savannah River Mill City: Rincon County: Effingham AIRS #: Application #: 40890 Facility Name: Georgia-Pacific Consumer Products LP Savannah River Mill City: Rincon County: Effingham AIRS #: 04-13-103-00007 Application #: 40890 Date SIP Application Received: March 7, 2016 Date Title

More information

CITY OF MINNEAPOLIS GREEN FLEET POLICY

CITY OF MINNEAPOLIS GREEN FLEET POLICY CITY OF MINNEAPOLIS GREEN FLEET POLICY TABLE OF CONTENTS I. Introduction Purpose & Objectives Oversight: The Green Fleet Team II. Establishing a Baseline for Inventory III. Implementation Strategies Optimize

More information

Regulatory and Permitting Requirements of Stationary Generators In Delaware

Regulatory and Permitting Requirements of Stationary Generators In Delaware Regulatory and Permitting Requirements of Stationary Generators In Delaware Delaware - DNREC Air Quality Management February 7, 2006 Mark A. Prettyman and Guadalupe J. Reynolds Outline Regulation No. 1144

More information

Streamlining Multiple Applicable Requirements

Streamlining Multiple Applicable Requirements Streamlining Multiple Applicable Requirements What is Streamlining? 1. Streamlining is the process of determining one set of requirements to be incorporated into the Title V permit from among multiple

More information

Permit-by-Rule Application

Permit-by-Rule Application State of Georgia Department of Natural Resources Environmental Protection Division Air Protection Branch Permit-by-Rule Application Atlanta Tradeport, Suite 120 4244 International Parkway Atlanta, Georgia

More information

STATEMENT OF BASIS. Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number

STATEMENT OF BASIS. Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number STATEMENT OF BASIS Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number 701-0013 Introduction On June 30, 2017, the Department received an application to renew the Title V Major Source

More information

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations The purpose of this document is to coalesce the various

More information

State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE

State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE-09-005-05 The diesel emission control strategy described herein qualifies as a potential compliance option for the Air Resources Board's (ARB)

More information

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks. RULE 4622 GASOLINE TRANSFER INTO MOTOR VEHICLE FUEL TANKS (Adopted May 21, 1992; Amended November 18, 1992; Amended December 17, 1992; Amended February 17, 1994; Amended June 18, 1998; Amended September

More information

STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted June 20, 2013)

STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted June 20, 2013) RULE 9610 STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted June 20, 2013) 1.0 Purpose The purpose of this rule is to provide an administrative mechanism

More information

State of New Jersey. Department of Environmental Protection Air Quality Permitting

State of New Jersey. Department of Environmental Protection Air Quality Permitting GP021 State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP 021) Combined Heat and Power Combustion Turbine(s) less than or equal to 65 MMBTU per hour This

More information

Combustion Control Problem Solution Combustion Process

Combustion Control Problem Solution Combustion Process Combustion Control Problem Until recent years, only the largest boilers could justify sophisticated combustion controls. Now, higher fuel costs and occasionally limited fuel availability make it necessary

More information

Proposed Rule Amendment

Proposed Rule Amendment Department of Environmental Protection Promulgation of Amendments to Chapter 2 of Title 15 of the Rules of the City of New York Rules Governing the Emissions from the Use of #4 and #6 Fuel Oil in Heat

More information

San Joaquin Valley AIR POLLUTION CONTROL DISTRICT

San Joaquin Valley AIR POLLUTION CONTROL DISTRICT San Joaquin Valley AIR POLLUTION CONTROL DISTRICT AUG 1 5 2014 Mr. John Haley Aera Energy LLC PO Box 11164 Bakersfield, CA 93389 k or HEALTHY AIR LIVING Re: Final - Authority to Construct / COC (Significant

More information

TITLE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT

TITLE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT 250-RICR-120-05-8 TITLE 250 - DEPARTMENT OF ENVIRONMENTAL MANAGEMENT CHAPTER 120 - AIR RESOURCES SUBCHAPTER 05 - AIR POLLUTION CONTROL PART 8 - Sulfur Content of Fuels 8.1 Purpose The purpose of this regulation

More information

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT DRAFT STAFF REPORT Draft Amendments to Rule 4621 (Gasoline Transfer into Stationary Storage Containers, Delivery Vessels, and Bulk Plants) and Rule 4622 (Gasoline Transfer into Motor Vehicle Fuel Tanks)

More information

DRAFT AUTHORITY TO CONSTRUCT

DRAFT AUTHORITY TO CONSTRUCT A/C NO.: 25780 ISSUED BY: DATE ISSUED: TBD JORGE DEGUZMAN DATE EXPIRES: ISSUED TO: TBD PRIME DATA CENTERS DBA SVO BUILDING ONE LLC LOCATION: 2407 AK ST., MCCLELLAN PARK, CA 95652 DESCRIPTION: IC ENGINE

More information