Enclosed Molded Case Circuit Breakers

Size: px
Start display at page:

Download "Enclosed Molded Case Circuit Breakers"

Transcription

1 Enclosed Motor Controllers and Molded Case Circuit Breakers KTA7 Type-E Self Protected Manual Motor Controllers Page 89 Explosion-Proof Motor Controllers KTA7_EX Page 9 The following pages contain a selection of single enclosed KTA7 & KTC7 motor controllers which can be applied as an individual Manual Self-Protected Combination Motor Controller or as an individual Manual Motor Starter dependent on the ratings of the individual unit. A Self-protected Combination Motor Controller (U08 Construction Type E) performs all the functions of a Manual Combo starter including a U approved means Disconnect with lockable and defeatable handle mechanism, short-circuit protection and overload protection for motor applications. A U08 Manual Motor Controller is a manual motor starter including a motor disconnect combined with an overload relay. Both can be combined with auxiliary contacts, shunt-trip or under-voltage trip units to meet your application requirements. The section that follows includes non-metallic enclosures, metallic enclosures and explosionproof enclosures. Enclosed Molded Case Circuit Breakers The following pages contain a selection of individual enclosed KTU7 molded case circuit breakers for the protection of non-motor loads. KTU7 is a 480Y/77Volt or 600Y/47 volt U489 approved circuit breaker and the selection of enclosures or combined with matching environmentally approved thru-thedoor handle disconnect mechanism which also complies with U489 standards. KTU7 offers at least 6 KAIC withstand ratings which exceeds those offered by many 600 Volt Class Molded Case Circuit Breakers which are larger and more expensive. Enclosed KTU7 can be combined with auxiliary contacts, shunt-trip or under-voltage trip units to meet your application requirements. Enclosed Type E/ Combination Starters KTA7 or KTC7 can be applied in combination with a CA7 contactor for remote control and an enclosure with matching environmentally approved thru-the-door handle disconnect mechanism to meet all requirements for a Construction Type E or Combination Starter. The following pages contain a selection of individual Combo starters which are smaller and less expensive than Classic Construction Type A (usible), or Type C (Thermal-magnetic Molded Case CX7 Ecombo Circuit Breaker) as KWIKStarters offered in Section C Page 98 of this catalog. The following types are offered: Non-metallic enclosed Combo KwikStarter CX7 and CXU7 with or DC coils available as factory assembled or in kit form for field assembly Metallic enclosed Combo CX7 and CXU7with or DC coils Explosion-proof enclosed CX7 and CXU7with or DC coils A variety of modifications are available. 88 KTA7_EZ Page KTU7 Molded Case Circuit Breakers Page 9 CX7 Combination Controllers Page 0 SSNA08

2 Type E Self-Protected Manual Motor Controller Enclosed KTA7 - IP6 Non-metallic (IP6) Enclosure Non-metallic (IP6) enclosure with integrated IP6 operator watertight, dusttight KT7-S/S (Standard Interrupting Capacity) Type E Self-protected Combination Manual Controller ➎ (Cat.# KT7--TE) Gray and black IP6 handle ➍➎ O/ Relay V 0V 00V 0V 7V Catalog ➍ KTA7-S/S Standard Interrupting Capacity KTA7-S-0.6A-CG 67 AY KTA7-S-0.A-CG 67 AY / KTA7-S-0.4A-CG 67 AY /4 / KTA7-S-0.6A-CG 400 AY / / KTA7-S-A-CG 400 AY /0 /4 /.0.6 KTA7-S-.6A-CG 400 AY /0 /6 / /4 -/.6. KTA7-S-.A-CG 400 AY /8 /. 4 KTA7-S-4A-CG 400 AY /4 /4 -/ ➏ KTA7-S-6.A-CG 400 AY / -/ 7-/ 0 ➏ KTA7-S-0A-CG 400 AY 0 ➏ KTA7-S-6A-CG 44 AY -/ 7-/ 0 ➏ KTA7-S-0A-CG 44 AY 7-/ ➏ 7-/ ➏ 0 ➏ 0 ➏ 8 KTA7-S-A-CG ➏ 44 AY 7-/ ➏ 0 ➏ 0 ➏ ➏ KTA7-S-9A-CG ➏ AY 7-/ ➏ 0 ➏ ➏ 0 ➏ KTA7-S-A-CG ➏ AY This item is available in the ORANGE E PRESS -day shipping program Enclosure Only Catalog Gray/Black handle KT7-AYTG 9 Red/Yellow handle KT7-AYTJ 9 Accessory Ground (PE) Terminal KS7-AYMTN 7 Modifications (actory Assembled) ront Mount 00V max. NO Auxiliary NC Auxiliary NO + NC Auxiliary NO Auxiliaries NO SC+O + NC Auxiliary NO SC+O + NO Auxiliary NC Auxiliaries NO Auxiliaries NO + NC Auxiliary NO SC+O+ NO SC NO SC+O+ NC SC NC SC+O+ NO SC -A0 -A0 -A -A0 -T0A0 -T0A0 -AS0 -AS0 -AS -R0 -R selection of the controller depends on the actual motor full load current and or motor with service factor less than.. Use motor nameplate full load current times 0.9 and choose the motor starter with the appropriate current range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. Refer to page for applied KAIC ratings. ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote for device selection criteria. ➍ A red and yellow handle may be selected instead of the standard gray and black handle. Change CG suffix to CJ. Ex: Change KTA7-S-0.6-CG to KTA7-S-0.6-CJ. ➎ Handles are built-in to the enclosure and are not available as components. ➏ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. Voltage 0 Hz 60 Hz 4V V 4V 8V 4V 8V 0V 0V 0V 7V 0V 7V 0V 0...0V 40V V 77V 40V 77V V V 0V SSNA08 89

3 Type E Self Protected Manual Motor Controller Enclosed KTA7 - Type 4 / 4X / Type 4 / 4X / enclosure watertight, dusttight, corrosion resistant KTA7 Type E Self-protected Combination Manual Controller (Standard Interrupting Capacity) ➎ Non-metallic, Type 4 / 4X / Enclosure (Cat.# KT7--TE or KT7-4-TE) V 0V 00V 0V /0 /4 / /0 /6 / /4 /8 / /4 /4 -/ / -/ -/ 7-/ 7-/➏ 7-/ ➎ 7-/ ➎ 0 ➎ 7-/ ➎ 0 ➎ /0 /6 / /4 /8 / /4 / -/ / -/ -/ 7-/ 7-/ 7-/ 7-/ ➎ 0 ➎ 7-/ ➎ 0 ➎ / -/ -/ 7-/ 7-/ 0 7-/ 0 0 7V O/ Relay Catalog ➍ KTA7-S/S Standard Interrupting Capacity KTA7-S-0.6A-VG KTA7-S-0.A-VG / KTA7-S-0.4A-VG / KTA7-S-0.6A-VG / KTA7-S-A-VG.0.6 KTA7-S-.6A-VG.6. KTA7-S-.A-VG. 4 KTA7-S-4A-VG KTA7-S-6.A-VG ➎ KTA7-S-0A-VG 0 ➎ KTA7-S-6A-VG ➎ KTA7-S-0A-VG 0 ➎ 0 ➎ 8 KTA7-S-A-VG ➎ ➎ KTA7-S-9A-VG ➎ 0 ➎ KTA7-S-A-VG ➎ KTA7-H/H High Interrupting Capacity -/.6. KTA7-H-.A-VG. 4 KTA7-H-4A-VG KTA7-H-6.A-VG 7-/ KTA7-H-0A-VG KTA7-H-6A-VG 0 ➎ KTA7-H-0A-VG 0 0 ➎ 8 KTA7-H-A-VG 0 ➎ ➎ KTA7-H-9A-VG ➎ ➎ 0 ➎ KTA7-H-A-VG ➎ KTA7-4H High Interrupting Capacity 7-/ 7-/ KTA7-4H-0A-VG KTA7-4H-6A-VG KTA7-4H-0A-VG KTA7-4H-A-VG 0 46 KTA7-4H-A-VG 0 40 ➎ 4 8 KTA7-4H-4A-VG /4 / -/ 7-/ 0 0 ➎ 0 ➎ ➎ Gray and black Type 4/4X/; IP66 handle (Cat.# KT7-HTN) ➍ Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Modifications (actory Assembled) ront Mount 00V max. NO Auxiliary NC Auxiliary NO + NC Auxiliary NO Auxiliaries NO SC+O + NC Auxiliary NO SC+O + NO Auxiliary NC Auxiliaries NO Auxiliaries NO + NC Auxiliary NO SC+O+ NO SC NO SC+O+ NC SC NC SC+O+ NO SC -A0 -A0 -A -A0 -T0A0 -T0A AS0 -AS0 -AS -R0 -R V 8V 0V 7V 0V 40V 77V Voltage 0 Hz 60 Hz V 4V 4V 8V 0V 0V 0V 7V 0...0V V 40V 77V V V 0V This item is available in the ORANGE E PRESS -day shipping program or motor with service factor less than.. Use motor nameplate full load range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. Refer to page for applied KAIC ratings. 90 ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote for device selection criteria. ➍ A red and yellow handle may be selected instead of the standard gray and black handle. Change VG suffix to VJ. Ex: Change KTA7-S-0.6-VG to KTA7-S-0.6-VJ. ➎ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. visit for pricing - All pricing and theshown most in upus to dollars date information SSNA08

4 Type E Self-Protected Manual Motor Controller Enclosed KTA7 - Type Type enclosure dusttight KT7-S/S (Standard Interrupting Capacity) Type E Self-protected Combination Manual Controller ➎ Painted Steel, Type Enclosure (Cat.# KT7--TE) V 0V 00V 0V /0 /4 / /0 /6 / /4 /8 / /4 /4 -/ / -/ -/ 7-/ 7-/ ➎ 7-/ ➎ 7-/ ➎ 0 ➎ 7-/ ➎ 0 ➎ /0 /6 / /4 /8 / /4 / -/ / -/ -/ 7-/ 7-/ 7-/ 7-/ ➎ 0 ➎ 7-/ ➎ 0 ➎ 7V Catalog ➍ KTA7-S/S Standard Interrupting Capacity KTA7-S-0.6A-DG KTA7-S-0.A-DG / KTA7-S-0.4A-DG /4 / KTA7-S-0.6A-DG / / KTA7-S-A-DG.0.6 KTA7-S-.6A-DG -/.6. KTA7-S-.A-DG. 4 KTA7-S-4A-DG KTA7-S-6.A-DG ➎ KTA7-S-0A-DG 7-/ 0 ➎ KTA7-S-6A-DG 0 ➎ KTA7-S-0A-DG 0 ➎ 0 ➎ 0 ➎ 8 KTA7-S-A-DG ➎ 0 ➎ ➎ KTA7-S-9A-DG ➎ ➎ 0 ➎ KTA7-S-A-DG ➎ KTA7-H/H High Interrupting Capacity -/.6. KTA7-H-.A-DG. 4 KTA7-H-4A-DG KTA7-H-6.A-DG 7-/ KTA7-H-0A-DG KTA7-H-6A-DG KTA7-H-0A-DG 0 ➎ 8 KTA7-H-A-DG 0 0 ➎ 0 ➎ ➎ KTA7-H-9A-DG ➎ ➎ 0 ➎ KTA7-H-A-DG ➎ Modifications (actory Assembled) ront Mount 00V max. NO Auxiliary NC Auxiliary NO + NC Auxiliary NO Auxiliaries NO SC+O + NC Auxiliary NO SC+O + NO Auxiliary NC Auxiliaries NO Auxiliaries NO + NC Auxiliary NO SC+O+ NO SC NO SC+O+ NC SC NC SC+O+ NO SC -A0 -A0 -A -A0 -T0A0 -T0A AS0 -AS0 -AS -R0 -R V 8V 0V 7V 0V 40V 77V Voltage 0 Hz 60 Hz V 4V 4V 8V 0V 0V 0V 7V 0...0V V 40V 77V V V 0V This item is available in the ORANGE E PRESS -day shipping program or motor with service factor less than.. Use motor nameplate full load range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. Refer to page for applied KAIC ratings. ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote for device selection criteria. ➍ A red and yellow handle may be selected instead of the standard gray and black handle. Change DG suffix to DJ. Ex: Change KTA7-S-0.6-DG to KTA7-S-0.6-DJ. ➎ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. SSNA08 visit for pricing - All pricing and theshown most in upus to dollars date information 9 O/ Relay Gray and black Type 4/4X/; IP66 handle (Cat.# KT7-HTN) ➍

5 Type E Self-Protected Manual Motor Controller Enclosed KTA7 - Type 4 / Painted Steel, Type 4 / Enclosure Type 4 / enclosure watertight, dusttight KT7-S/S (Standard Interrupting Capacity) Type E Self-protected Combination Manual Controller ➎ (Cat.# KT7--TE or KT7-4-TE) V 0V 00V 0V /0 /4 /0 /6 / /8 / /4 /4 -/ / -/ -/ 7-/ ➎ 7-/ ➎ 7-/ ➎ / /4 7-/ 7-/ ➎ 0 ➎ 0 ➎ /0 /6 / /8 / /4 / -/ / -/ -/ 7-/ 7-/ ➎ 7-/ ➎ /4 7-/ 7-/ 0 ➎ 0 ➎ / -/ -/ 7-/ 7-/ 0 7-/ 0 0 7V O/ Relay Catalog ➍ KTA7-S/S Standard Interrupting Capacity KTA7-S-0.6A-WG KTA7-S-0.A-WG / KTA7-S-0.4A-WG /4 / KTA7-S-0.6A-WG / / KTA7-S-A-WG.0.6 KTA7-S-.6A-WG -/.6. KTA7-S-.A-WG. 4 KTA7-S-4A-WG KTA7-S-6.A-WG ➎ KTA7-S-0A-WG 7-/ 0 ➎ KTA7-S-6A-WG 0 ➎ KTA7-S-0A-WG 0 ➎ 0 ➎ 0 ➎ 8 KTA7-S-A-WG ➎ 0 ➎ ➎ KTA7-S-9A-WG ➎ ➎ 0 ➎ KTA7-S-A-WG ➎ KTA7-H/H High Interrupting Capacity -/.6. KTA7-H-.A-WG. 4 KTA7-H-4A-WG KTA7-H-6.A-WG 7-/ KTA7-H-0A-WG KTA7-H-6A-WG KTA7-H-0A-WG 0 ➎ 8 KTA7-H-A-WG 0 0 ➎ 0 ➎ ➎ KTA7-H-9A-WG ➎ ➎ 0 ➎ KTA7-H-A-WG ➎ KTA7-4H High Interrupting Capacity 7-/ 7-/ KTA7-4H-0A-WG KTA7-4H-6A-WG KTA7-4H-0A-WG KTA7-4H-A-WG 0 46 KTA7-4H-A-WG 0 40 ➎ 4 8 KTA7-4H-4A-WG or motor with service factor less than.. Use motor nameplate full load range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. Refer to page for applied KAIC ratings. 9 Gray and black Type 4/4X/; IP66 handle (Cat.# KT7-HTN) ➍ R/ R/ R/ R/ R/ R/ Modifications (actory Assembled) ront Mount 00V max. NO Auxiliary NC Auxiliary NO + NC Auxiliary NO Auxiliaries NO SC+O + NC Auxiliary NO SC+O + NO Auxiliary NC Auxiliaries NO Auxiliaries NO + NC Auxiliary NO SC+O+ NO SC NO SC+O+ NC SC NC SC+O+ NO SC -A0 -A0 -A -A0 -T0A0 -T0A AS0 -AS0 -AS -R0 -R V 8V 0V 7V 0V 40V 77V Voltage 0 Hz 60 Hz V 4V 4V 8V 0V 0V 0V 7V 0...0V V 40V 77V V V 0V ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote for device selection criteria. ➍ A red and yellow handle may be selected instead of the standard gray and black handle. Change WG suffix to WJ. Ex: Change KTA7-S-0.6-WG to KTA7-S-0.6-WJ. ➎ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. visit for pricing - All pricing and theshown most in upus to dollars date information SSNA08

6 Manual Motor Controller Explosion-Proof Series KTA7 KTA7 Explosion Proof Motor Controllers - NEMA Type 4/7/9 V 0V 00V 0V 7V O/ Relay Catalog KTA7-S Standard Interrupting Capacity KTA7-S-0.6A-EX 984 EX KTA7-S-0.A-EX 984 EX / KTA7-S-0.4A-EX 984 EX /4 / KTA7-S-0.6A-EX 0 EX / / KTA7-S-A-EX 0 EX /0 /4 /.0.6 KTA7-S-.6A-EX 0 EX /0 /6 / /4 -/.6. KTA7-S-.A-EX 0 EX /8 /. 4 KTA7-S-4A-EX 0 EX /4 /4 -/ ➍ KTA7-S-6.A-EX 0 EX / -/ 7-/ 0 ➍ KTA7-S-0A-EX 0 EX 0 ➍ KTA7-S-6A-EX 067 EX -/ 7-/ 0 ➍ KTA7-S-0A-EX 067 EX 7-/ ➍ 7-/➍ 0 ➍ 0 ➍ 8 KTA7-S-A-EX 067 EX 7-/ ➍ 0 ➍ 0 ➍ ➍ KTA7-S-9A-EX 68 EX 7-/ ➍ 0 ➍ ➍ 0 ➍ KTA7-S-A-EX 68 EX Class I, Div,, Group C, D Class II, Div,, Group E, & G enclosure Class III NEMA Type 4/7/9 KT7-S/S (Standard interrupting capacity) Type E Self-protected Combination Manual Motor Controller ➍ (Cat.# KT7--TE) Modifications (actory Assembled) ➎ KT7 Auxiliaries & Trip Contacts ront Mount 00V max. NO Auxiliary -A0 6 NC Auxiliary -A0 6 NO + NC Auxiliary -A NO Auxiliaries -A0 NO SC+O + NC Auxiliary -T0A0 NO SC+O + NO Auxiliary -T0A0 NO + NC Auxiliary -AS NO Auxiliaries -AS0 NC SC+O + NO Auxiliary -R0 NC SC+O + NC Auxiliary -R Enclosure Modifications Breather/Drain -BD or motor with service factor less than.. Use motor nameplate full load range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. Refer to page for applied KAIC ratings. ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote for device selection criteria. ➍ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. ➎ -UA and -AA options not possible in the -EX Enclosure. SSNA08 9

7 Self-protected Manual Motor Controller Explosion-Proof Series KTA7 KTA7 Explosion Proof Motor Controllers NEMA Type 4/7/9 with Gasket EY Enclosure shown Class I, Div,, Group C, D Class II, Div,, Group E, & G enclosure Class III NEMA Type 4/7/9 KT7 Type E Self-protected Combination Manual Motor Controller ➍ (Cat.# KT7--TE or KT7-4-TE) V 0V 00V 0V 7V O/ Relay Catalog KTA7-S Standard Interrupting Capacity KTA7-S-0.6A-EY EY KTA7-S-0.A-EY EY / KTA7-S-0.4A-EY EY /4 / KTA7-S-0.6A-EY 68 EY / / KTA7-S-A-EY 68 EY /0 /4 /.0.6 KTA7-S-.6A-EY 68 EY /0 /6 / /4 -/.6. KTA7-S-.A-EY 68 EY /8 /. 4 KTA7-S-4A-EY 68 EY /4 /4 -/ ➍ KTA7-S-6.A-EY 68 EY / -/ 7-/ 0 ➍ KTA7-S-0A-EY 68 EY 0 ➍ KTA7-S-6A-EY 0 EY -/ 7-/ 0 ➍ KTA7-S-0A-EY 0 EY 7-/ ➍ 7-/ ➍ 0 ➍ 0 ➍ 8 KTA7-S-A-EY EY 7-/ ➍ 0 ➍ 0 ➍ ➍ KTA7-S-9A-EY 04 EY 7-/ ➍ 0 ➍ ➍ 0 ➍ KTA7-S-A-EY 04 EY KTA7-H High Interrupting Capacity /0 /6 / /4 -/.6. KTA7-H-.A-EY 8 EY /8 /. 4 KTA7-H-4A-EY 8 EY /4 / -/ KTA7-H-6.A-EY 8 EY / -/ 7-/ KTA7-H-0A-EY 70 EY KTA7-H-6A-EY 70 EY -/ 7-/ 0 ➍ KTA7-H-0A-EY 70 EY 7-/ 7-/ 0 0 ➍ 8 KTA7-H-A-EY 70 EY 7-/ ➍ 0 ➍ 0 ➍ ➍ KTA7-H-9A-EY 40 EY 7-/ ➍ 0 ➍ ➍ 0 ➍ KTA7-H-A-EY 40 EY KTA7-4H High Interrupting Capacity / -/ 7-/ 7-/ KTA7-4H-0A-EZ 066 EZ KTA7-4H-6A-EZ 066 EZ -/ 7-/ KTA7-4H-0A-EZ 066 EZ KTA7-4H-A-EZ 066 EZ 7-/ KTA7-4H-A-EZ EZ 7-/ ➍ 4 8 KTA7-4H-4A-EZ EZ selection of the controller depends on the actual motor full load current and or motor with service factor less than.. Use motor nameplate full load current times 0.9 and choose the motor starter with the appropriate current range. Example: Motor C = 4.A; S.. =.0. 4.A x 0.9 =.78A. Select catalog number KTA7-S-4A. ➋ Magnetic trip is fixed at x the maximum value of the current adjustment range. See page for KAIC ratings. ➌ KTA7 may be applied to single phase loads if poles of device are wired in series. See footnote ➊ for device selection criteria. ➍ Catalog numbers with specific voltages 7V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page for ratings. Modifications (actory Assembled) ront Mount 00V max. NO Auxiliary NC Auxiliary NO + NC Auxiliary NO Auxiliaries NO SC+O + NC Auxiliary NO SC+O + NO Auxiliary NC Auxiliaries NO Auxiliaries NO + NC Auxiliary NO SC+O+ NO SC NO SC+O+ NC SC NC SC+O+ NO SC -A0 -A0 -A -A0 -T0A0 -T0A0 -AS0 -AS0 -AS -R0 -R Enclosure Modifications Breather/Drain -BD Voltage 0 Hz 60 Hz 4V V 4V 8V 4V 8V 0V 0V 0V 7V 0V 7V 0V 0...0V 40V V 77V 40V 77V V V SSNA08

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

FMotor Circuit Controllers & Circuit Breakers

FMotor Circuit Controllers & Circuit Breakers Motor Circuit Controllers & Circuit Breakers Motor Controllers and MCCBs Series KT7 Motor Circuit Controllers...2 Series KTA7 Base Units...4 Series KTC7 Base Units...6 Series KTB7 Base Units...8 Series

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Technical Information

Technical Information Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

Orange Express Selection Guide Table of Contents

Orange Express Selection Guide Table of Contents Orange Express Selection Guide Table of Contents General escription...2 KWKstarters...4 KWKstarters...6 KWKstarters Enclosure imensions...8 FVNR CA7 Contactors, Enclosed...10 FVR CA7 Contactors, Enclosed...11

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

FMotor Circuit Controllers

FMotor Circuit Controllers KTA7/KTB7 & KTC7 Bus Bar and Supply Blocks are in millimeters (inches). not intended for manufacturing purposes. KT7-32-A3E KT7-45-A3E KT7-32-DB KT7-45-DB KT7 ➌ ➍ Compact Busbar Feeder Terminal IEC Compact

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers Methods of Applying KT7 & Molded Case Circuit Breakers This information is provided to aid in proper system design and utilization of the KTA7, KTB7 & KTC7 Controller in North American applications. UL

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes) AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

Sprecher + Schuh DON'T SEE IT LISTED? CONTACT OUR SALES DEPARTMENT. *updated 02/03/16

Sprecher + Schuh DON'T SEE IT LISTED? CONTACT OUR SALES DEPARTMENT. *updated 02/03/16 Sprecher + Schuh The following items are in stock and can be shipped from our warehouse within 24 hours. To order, or for additional information, please contact our Sales Department at 1-800-821-5091.

More information

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

Type MS450 MS497. Phone: Fax: Web:  -   Manual motor protectors Manual motor protectors Type MS40 MS497 MS40 MS497 Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Horsepower ratings Three-phase 11V 230V

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

smissline Description

smissline Description Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Type S Contactors and Starters

Type S Contactors and Starters Type S Contactors and Starters Class 8536/8502/8736/8702/8810/8811/8812 CONTENTS Description Page Magnetic Contactors and Starters.......................................1 Reversing Magnetic Starters and

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

NEMA Control. Contactors & Starters Index

NEMA Control. Contactors & Starters Index Contactors & Starters Index Control Description Page Number General Information - TM... AC Magnetic Contactors - TM... AC Magnetic Reversing Contactors - TM... 6 AC Magnetic Starters - TM... AC Magnetic

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers Cerus TD and TS Series UL 489 Listed TD125U ln 15~125A 3.54(W) x 6.46(H) X 3.39in (D) TS250U ln150 ~ 250A 4.13 (W) x 7.01 (H) X 3.39in (D) TS400U ln 300 ~ 400A 5.51 (W) x 11.50

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Certi 堵脝 cation Record

Certi 堵脝 cation Record Certi 堵脝 cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 214 INDUSTRIAL CONTROL EQUIPMENTMotor Controllers Magnetic

More information

Electromechanical Level Control

Electromechanical Level Control Electromechanical Level Control Catalog 9034CT9701R2/08 08 Class 9036, 9037, and 9038 and Class 9049 Accessories CONTENTS Description..............................................Page Selection Guide..............................................

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

TDX - Taco Duplex Starter with

TDX - Taco Duplex Starter with Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

ESW/PESW. Non-Combination Starters

ESW/PESW. Non-Combination Starters ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin 140M Topic Page Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Accessories 17 Overview

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Bulletin 500 Top Wiring For Motor Loads

Bulletin 500 Top Wiring For Motor Loads Bulletin 500 Top Wiring For Motor Loads Catalog Number Explanation Example Cat. No. 500 B A D 930 1 a b c d e f a Bulletin No. Bulletin No. 500 Top-wired contactor 500DC Top-wired contactor (DC voltage)

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel: Specification MIL-C-2212 Application Motor control, heater and tungsten lamp switching. Type Select standard type (IC5181C) or quiet type (IC5181D) when control is to meet standard MIL-C-740. All quiet

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information