DCG Commercial Tons Packaged Gas / Electric Units

Size: px
Start display at page:

Download "DCG Commercial Tons Packaged Gas / Electric Units"

Transcription

1 DG ommercial - Tons Packaged Gas / Electric Units Tons ooling apacity: 80,000 BTU/h 0 Tons ooling apacity: 0,000 BTU/h Tons ooling apacity: 90,000 BTU/h Tons Heating apacity: 0,000 BTU/h 0 Tons Heating apacity: 00,000 BTU/h Tons Heating apacity: 00,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... Airflow Data... rankcase Heater... Electrical Data... Dimensions... Wiring Diagrams... for Models with DD ontrols...8 Accessories... Standard Features Patented tubular heat exchanger High-efficiency scroll compressor Aluminum micro-channel indoor coil on -ton units -ton units contain two outdoor fans opper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier -volt terminal strip ontactor with lugs Units meet the performance outlined in Table.8.- of ASHRAE Standard AHRI ertified; ETL Listed abinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish ondenser hail guards Full perimeter rail Built-in filter rack with standard " filters (convertible to " filters) Sloped drain pan * omplete warranty details available from your local dealer or at SS-DG / Supersedes 9/

2 Nomenclature D G B * * * A *,,,8,9 0 Revision Levels Major & Minor Brand Factory-Installed Options D Daikin X No Options A Non-powered convenience outlet onfiguration B Powered convenience outlet Standard Efficiency ( - Tons) Low-ambient kit S Standard Efficiency ( - Tons) D Return air smoke detector T High Efficiency ( - Tons) E Supply air smoke detector F Non-powered convenience outlet; Application Low-ambient kit ooling G Non-powered convenience outlet; G Gas Heat Return air smoke detector H Heat Pump H Non-powered convenience outlet; Supply air smoke detector Nominal ooling apacity J Non-powered convenience outlet; 0 Tons 0 8½ Tons 00 Tons Return & Supply air smoke detectors 08 Tons 0 0 Tons K Non-powered convenience outlet; 00 Tons 0 ½ tons Low-ambient kit; Supply air smoke detector 0 Tons 80 Tons L Non-powered convenience outlet; 090 ½ Tons 0 0 Tons Low-ambient kit Return & Supply air smoke detectors Nominal Heating apacity M Powered convenience outlet; Gas/Electric A/ H/P Factory-Installed Electric Heat Low-ambient kit 0,000 BTU/h XXX No Heat N Powered convenience outlet; ,000 BTU/h 00 0 kw 00 0 kw Return air smoke detector,000 BTU/h 0 kw 0 0 kw O Powered convenience outlet; 0 0,000 BTU/h 0 kw 0 kw Return & Supply air smoke detectors 0 0,000 BTU/h 08 8 kw 0 kw P Powered convenience outlet; 0 0,000 BTU/h 00 0 kw 00 0 kw Supply air smoke detector 00 00,000 BTU/h 0 kw Q Powered convenience outlet; Low-ambient See product specifications for heat size(s) available for each capacity. kit; Return air smoke detector R Powered convenience outlet; Low-ambient Voltage kit; Supply air smoke detector 08-0//0 0//0 T Powered convenience outlet; Low-ambient 08-0//0 //0 kit; Return & Supply air smoke detectors U Non-powered convenience outlet; Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detector D Direct Drive (- Tons) V Low-ambient kit; Return air smoke detector V Two-Speed Belt Drive (also designates -Ton with two-stage compressor) W Low-ambient kit; Supply air smoke detector W High Static (two-speed Belt Drive) Y Low-ambient kit; Return & Supply air smoke detectors Factory-Installed Options Z Return & Supply air smoke detectors A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; B DD-BAnet protocol DD-BAnet protocol; Factory-Installed Options F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) X Standard Aluminized Heat Exchanger DD-BAnet protocol V Low-Leak Downflow Economizer S Stainless-Steel Heat Exchanger H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer D Hinged Panels J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) K Stainless-Steel Heat Exchanger; Disconnect Switch (non-fused) X No Options Hinged Panels M Disconnect Switch (non-fused); DD-BAnet protocol B Phase Monitor J Stainless Steel Heat Exchanger; Phase Monitor Note: Not all options available for all products. M Hinged Panel; Phase Monitor X= No Options in character th L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor SS-DG

3 Nomenclature Factory-Installed Options Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 09-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to -ton units, cooling operation is extended from 0 F ambient temperature to F outside air temperature. On ½ -0 ton units, cooling operation is extended from F ambient temperature to 0 F outside air temperature. For ton units, cooling operation is extended from F ambient temperature to 0 F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (A and heat pump units only): Available in all voltage options. Non-powered onvenience Outlet: A 0V, A, GFI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered onvenience Outlet: A 0V, A, GFI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by.a/.a for 08/0V units, increase by.a for 0V units, and by.a for V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused; -phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DS units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. ombined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. Two-speed indoor fan blower models are standard on, ½, 8½, 0, ½,, 0 & ton units. Section...0.b of ASHRAE Standard and Section...a of ASHRAE Standard require a minimum of two fan speeds. Section 0.(m) of alifornia Energy ommission Title 0 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is % of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. Phase Monitor: Phase monitor ( phase only), available for - ton DS, D and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. DD ontroller: DD communicating controller, available for - ton DS, D and DT series models with on-board BAnet communication interface. High static blower assembly, factory-installed SS-DG

4 Product Specifications Tons DG80 0V***A* DG80 0V***A* DG80 0V***A* ooling apacity Total, BTU/h 80,000 80,000 80,000 Sensible BTU/h,00,00,00 EER / IEER 0.8 /. 0.8 /. 0.8 /. Decibels AHRI Reference #s Heating apacity High Input/Output (KBTU/h) 0 / 80 0 / 80 0 / 80 Low Input/Output (KBTU/h). / 0. / 0. / 0 Steady State Efficiency (%) Temperature Rise: High / Low ( F) 0-0 / / / 0-0 No. of Burners Evaporator Motor / oil Motor Type (Belt Drive) -speed Belt Drive -speed Belt Drive -speed Belt Drive Indoor Nominal FM,00,00,00 Indoor Motor FLA (ooling).. Horsepower - RPM.0 -,/8.0 -,/8.0 -,0/8 Metering Device TXV TXV TXV Filter Size (#) 0 x x () 0 x x () 0 x x () Drain Size (NPT) R-0A Refrigerant harge ir # R-0A Refrigerant harge ir # Evaporator oil Face Area (ft²) Rows Deep / Fins per Inch / / / Belt Drive Evap Fan Data # of Wheels (D x W) ( x ) ( x ) ( x ) Motor Sheave VP0 x ⅜ VP0 x ⅜ VP0 x ⅜ Blower Sheave 0 x ³/₁₆ 0 x ³/₁₆ 0 x ³/₁₆ Belt BX8 BX8 BX8 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - RPM ⅓ -,0 ⅓ -,0 ⅓ -,0 Fan Diameter / # Fan Blades / / / Outdoor Nominal FM 9,000 9,000 9,000 Face Area (ft²)... Rows Deep / Fins per Inch / / / ompressor Quantity / Type / Scroll / Scroll / Scroll ompressor RLA / LRA IR. # /. / / 8 ompressor RLA / LRA IR. # /. / / 8 Electrical Data Voltage / Phase / Frequency 08/ Standard Max Static... Outdoor Fan FLA / LRA.0/. 0.8 /. 0. /.8 Total Unit Amps Min. ircuit Ampacity¹. /... Max. Overcurrent Protection (amps)² 00 / 00 Entrance Power Supply ⅛ ⅛ ⅛ Entrance ontrol Voltage ⅞ ⅞ ⅞ Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

5 Product Specifications 0 Tons DG0 00V***B* DG0 00V***B* DG0 00V***B* ooling apacity Total, BTU/h 0,000 0,000 0,000 Sensible BTU/h 0,000 0,000 0,000 EER / IEER 9.8 /. 9.8 /. 9.8 /. Decibels AHRI Reference #s Heating apacity High Input/Output (KBTU/h) 00 / 0 00 / 0 00 / 0 Low Input/Output (KBTU/h) 00 / 0 00 / 0 00 / 0 Steady State Efficiency Temperature Rise Range ( F) High/Low - / - - / - - / - No. of Burners Evaporator Motor / oil Motor Type (Belt Drive) -speed Belt Drive -speed Belt Drive -speed Belt Drive Indoor Nominal FM,000,000,000 Indoor Motor FLA (ooling).. Horsepower - RPM.0 -,/8.0 -,/8.0 -,0/8 Metering Device TXV TXV TXV Filter Size (#) 0 x x () 0 x x () 0 x x () Drain Size (NPT) R-0A Refrigerant harge ir #s & & 9 ozs. & 9 ozs. & 9 ozs. Evaporator oil Face Area (ft²) Rows Deep / Fins per Inch / / / Belt Drive Evap Fan Data # of Wheels (D x W) ( x ) ( x ) ( x ) Motor Sheave VP0 x ⅜ VP0 x ⅜ VP0 x ⅜ Blower Sheave 00 x ⁷/₁₆ 00 x ⁷/₁₆ 00 x ⁷/₁₆ Belt BX BX BX ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - RPM ⅓ -,0 ⅓ -,0 ⅓ -,0 Fan Diameter / # Fan Blades / / / Outdoor Nominal FM 9,000 9,000 9,000 Face Area (ft²)... Rows Deep / Fins per Inch / / / ompressor Quantity / Type / Scroll / Scroll / Scroll ompressor RLA / LRA ea..0 / / / 0. Electrical Data Voltage / Phase / Frequency 08/ Standard Max Static... Outdoor Fan FLA / LRA.0 /. 0.8 /. 0. /.8 Total Unit Amps Min. ircuit Ampacity¹ 9. / 9... Max. Overcurrent Protection (amps)² / 0 Entrance Power Supply ⅛ ⅛ ⅛ Entrance ontrol Voltage ⅞ ⅞ ⅞ Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

6 Product Specifications Tons DG00 00V***A* DG00 00V***A* DG00 00V***A* ooling apacity Total, BTU/h 90,000 90,000 90,000 Sensible BTU/h 9,000 9,000 9,000 EER / IEER 9.8 /. 9.8 /. 9.8 /. Decibels AHRI Reference #s Heating apacity High Input/Output (KBTU/h) 00 / 0 00 / 0 00 / 0 Low Input/Output (KBTU/h) 00 / 0 00 / 0 00 / 0 Steady State Efficiency Temperature Rise Range ( F) High/Low - / - - / - - / - No. of Burners Evaporator Motor / oil Motor Type (Belt Drive) -speed Belt Drive -speed Belt Drive -speed Belt Drive Indoor Nominal FM 8,00 8,00 8,00 Indoor Motor FLA (ooling) Horsepower - RPM. - 0/. - 0/. - 0/ Metering Device TXV TXV TXV Filter Size (#) 0 x 0 x (8) 0 x 0 x (8) 0 x 0 x (8) Drain Size (NPT) " " " R-0A Refrigerant harge ir #s & & 98 ozs. & 98 ozs. & 98 ozs. Evaporator oil Face Area (ft²)... Rows Deep / Fins per Inch / / / Belt Drive Evap Fan Data # of Wheels (D x W) (" x ") (" x ") (" x ") Motor Sheave VP8 x ⅜" VP8 x ⅜" VP8 x ⅜" Blower Sheave 0 x ⁷/₁₆" 0 x ⁷/₁₆" 0 x ⁷/₁₆" Belt BX BX BX ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - RPM Fan Diameter / # Fan Blades 0 / 0 / 0 / Outdoor Nominal FM,000,000,000 Face Area (ft²)... Rows Deep / Fins per Inch / / / ompressor Quantity / Type / Scroll / Scroll / Scroll ompressor RLA / LRA IR. # 8. / 8. /. / 00 ompressor RLA / LRA IR. # 8. / 8. /. / 00 Electrical Data Voltage / Phase / Frequency 08/ Outdoor Fan FLA / LRA./../../. Total Unit Amps Min. ircuit Ampacity¹ /.. Max. Overcurrent Protection (amps)² / 0 0 Entrance Power Supply ⅛" ⅛" ⅛" Entrance ontrol Voltage ⅞" ⅞" ⅞" Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

7 Expanded ooling Data Tons (two-speed motor at high speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T 8 0 HI PR LO PR MBh S/T T HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. SS-DG

8 Expanded ooling Data Tons (two-speed motor at high speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T 0 9 HI PR LO PR MBh S/T T 0 HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T 0 HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 8 SS-DG

9 Expanded ooling Data 0 Tons (two-speed motor at high speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T 0 HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. SS-DG 9

10 Expanded ooling Data 0 Tons (two-speed motor at high speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T 0 HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T 0 HI PR LO PR MBh S/T T HI PR LO PR MBh S/T T HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 0 SS-DG

11 Expanded ooling Data Tons (Two-Speed Motor at High Speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) Rating onditions. kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps: Unit amps (comp.+ evaporator + condenser fan motors) Design Subcooling, - 9 the liquid access fitting connection ARI 9 test conditions. Design Superheat 8 - the compressor suction access fitting connection. SS-DG

12 Expanded ooling Data Tons (Two-Speed Motor at High Speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T 9. kw HI PR LO PR MBh S/T T 0.0 kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T 9.9 kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) Rating onditions. kw = Total system power High and low pressures are measured at the liquid and suction access fittings. Amps: Unit amps (comp.+ evaporator + condenser fan motors) Design Subcooling, - 9 the liquid access fitting connection ARI 9 test conditions. Design Superheat 8 - the compressor suction access fitting connection. SS-DG

13 Airflow Data & 0 Tons DG Tons Standard Two-Speed Belt Drive at High Speed ESP In" H₂O Turns Open 0 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ,8.,9.9, ,09.09,.,.,0.98, ,90.8,0.80,9.0,.09, ,.9,98.99,8., ,9.989, , DG Tons High-Static Belt Drive Two-Speed at High Speed ESP In" H₂O Turns Open 0 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP DG 0 Tons Standard Two-Speed Belt Drive at High Speed ESP In" H₂O Turns Open 0 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ,9.9 8, ,. 8,88.9, ,08.8 8,.88 8,.89,8.,.88, ,9.98,89.8,8.999, ,9.880,.0, ,9.09, , Notes Airflow table represent dry coil with filters installed; SFM correction factor for wet coil is %. Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application that exceed the above could require a larger motor. Minimum rated SFM is 0 per ton. Unit factory shipped with the sheave set at. turns open. SS-DG

14 Airflow Data 0 & Tons ESP In" H₂O DG 0 Tons High-Static Belt Drive Two-Speed at High Speed Turns Open 0 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP DG Tons Standard Two-Speed Belt Drive at High Speed Turns Open 0 RPM ESP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP 0. 9,90. 9,.80 8,99. 8,. 8,8. 8,00.00,. 0. 9,.0 8,8. 8,9.9,90.9,0.90,., ,88.0 8,9.,9.0,8.0,00., ,0.,.80,9.9, ,.98,99., , DG Tons High Static Two-Speed at High Speed Turns Open 0 RPM ESP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP SFM BHP ,8. 9, ,8. 9,9. 8, ,. 9,.0 8,.9, ,0.0 8,0.,88., , ,.8,9.8,8., , ,.88,.,088., ,9.,., ,.8,., ,.9, , Notes Airflow table represent dry coil with filters installed; SFM correction factor for wet coil is %. Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application that exceed the above could require a larger motor. Minimum rated SFM is 0 per ton. Unit factory shipped with the sheave set at. turns open. Airflow Pressure Drop of Downflow Economizer for - to -Ton Rooftop Units (00% Return Air FM,00,000,00,000,00,000,00 8,000 8,00 9,000 9,00 0,000 (In. WG) SS-DG

15 rankcase Heater, High Efficiency MERV Air Filter Option High Efficiency MERV Air Filter Option 0.0 Flanders Pre Pleat M Air Velocity vs Resistance (Test Size: " x " x " High apacity) " Deep Resistance (in. w.g.) Air Velocity (FPM) Tonnage: Filter Nominal Size: Part Number: Order QTY:, 0 0 x x 00L000 0 X 0 X 00L000 8 rankcase Heater Selection Table ompressor Voltage rankcase ZP/ZPS ompressor Diameter 0V 0V V Heater Watts -." 0R0000S 0R000S 0R000S /." 00L000S 00L0008S 00L0009S L0000S 00L000S 00L000S 90 D* Tonnage ompressor Voltage 0V 0V V rankcase Heater Watts -0 Ton** 00L000S 00L0008S 00L0009S 0 Ton 00L0000S 00L000S 00L000S 90 *Includes,G&H models. **If ompressor Diameter is 9. then use Ton rankcase heaters. SS-DG

16 Electrical Data Tons Model Number 0 Tons Tons Electrical Rating ompressor ircuit ompressor ircuit Outdoor Fan Motor Indoor Fan Motor Optional Powered onvienience Outlet Power Supply RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MA MOP DG80***W 08/ speed High Static Belt Drive.0 0. DG80***V 08/ speed Belt Drive.00.0 DG80***W speed High Static Belt Drive.0 9. DG80***V speed Belt Drive.00. DG80***W speed High Static Belt Drive.0. DG80***V speed Belt Drive.00. Model Number Electrical Rating ompressor ircuit ompressor ircuit Outdoor Fan Motor Indoor Fan Motor - 8. / / 00. / / / 0 -. /. 00 / 00. /. 8. / / Optional Powered onvienience Outlet Power Supply RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MA MOP DG0***W 08/ speed High Static Belt Drive.0 0. DG0***V 08/ speed Belt Drive.00.0 DG0***W speed High Static Belt Drive.0 9. DG0***V speed Belt Drive.00. DG0***W speed High Static Belt Drive.0. DG0***V speed Belt Drive.00. Model Number Electrical Rating ompressor ircuit ompressor ircuit Outdoor Fan Motor Indoor Fan Motor - 0 / 0 /. /. 0 / 09 / - 9. / 9. /. /. 0 / 0 / Optional Powered onvienience Outlet Power Supply RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MA MOP DG00***W 08/ speed High Static Belt Drive.0.0 DG00***V 08/ speed Belt Drive.0.0 DG00***W speed High Static Belt Drive.0 0. DG00***V speed Belt Drive.0 0. DG00***W speed High Static Belt Drive.0 8. DG00***V speed Belt Drive / 8 /. /. / / - 8 / 8 /. /. / / SS-DG

17 Dimensions & 0 Tons TOP VIEW FK HOLES BOTH SIDES AND ONDENSER END LIFT SHAKLE HOLES BOTH SIDES AND ENDS ONDENSATE DRAIN OUTLET THIS SIDE ONLY.. BAK VIEW ALL DIMENSIONS ARE GIVEN IN INHES ALL DIMENSIONS AND SPEIFIATIONS ARE SUBJET TO HANGE WITHOUT NOTIFIATION LINE WIRE ENTRANE 88. LEFT END VIEW D*80/0*** AND 0 TON OMERIAL DISONNET SWITH LOATION (if applicable) TSTAT WIRE ENTRANE SS-DG

18 Dimensions, 0, & Tons ONDENSATE DRAIN BOTTOM EXIT X X RETURN AIR DUT SUPPLY AIR DUT.000 BASE PAN VIEW (VIEWED FROM TOP DOWN) 8 SS-DG

19 Dimensions Tons TOP VIEW. FK HOLES BOTH SIDES AND ONDENSER END ONDENSATE DRAN OUTLET THIS SIDE ONLY LEFT SHAKLE HOLES BOTH SIDES AND ENDS. BAK VIEW ALL DIMENSION GIVEN ARE IN INHES ALL DIMENSIONS AND SPEIFIATIONS ARE SUBJET TO HANGE WITHOUT NOTIE LEFT END VIEW LINE WIRE ENTRANE TSTAT WIRE ENTRANE D*00*** -TON OMMERIAL SS-DG 9

20 Unit learances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 8 on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit Ingestion of exhaust air into the unit s fresh-air intake. 8" " " 8" " MINIMUM " MINIMUM ROOF OVERHANG ROOF OVERHANG Electrical Entrance Locations ¹/₈ ³/₅ High-Voltage Entrance ⁴/₅ 0 LowVoltage Entrance SS-DG

21 EVAPAT OILS Roof urb Installation Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 0". Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, ductwork should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof urb Installation Instructions Manual. Refer to the Roof urb Installation Instructions for proper curb installation. urbing must be installed in compliance with the National Roofing ontractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. heck for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. A Y 0 B OMPRESS ompressor OMPRESS ompressor 0" X G Supply Evaporator oil orner & enter-of-gravity Locations Return D -Ton Units Weights (bls.) 0-Ton Units Weights (lbs.) -Ton Units Weights (lbs.) Weight A 8 Weight A Weight A Weight B Weight B Weight B Weight Weight 89 Weight 0 Weight D Weight D 8 Weight D Shipping Weight 98 Shipping Weight Shipping Weight Operating Weight 08 Operating Weight Operating Weight 8 Note: These weights are calculated without installed accessories. SS-DG

22 Roof urb Installation urb installations must comply with local codes and should follow the established guidelines of the National Roofing ontractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. heck for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. antilevered-type curbs are not available from the factory. ontractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. urb Top O.D. 9¾ urb Top O.D. ²/₂₅ ²/₂₅ ²/₂₅ ¾ urb O.D. ⅞ ⅞ ⅞ 8 urb Top O.D. Insulated Panels ¼ ⅝ Typ. ¾ urb Bottom O.D. ⅜ Typ. ¾ ½ urb Bottom O.D. SS-DG

23 9 8 Wiring Diagram DG & 0 Tons (0V Two-Speed Belt Drive) H HR OMP T T T T T T L L L PB HR VM SEE NOTE PLF HPS LPS H HPS LPS T OMP T T HIGH EM LOW VMR R R T T T T T T B HIGH SPEED L L L B LOW SPEED L L L T T T T T T T T T L L L L L B L L L B L TR 08 0 V SEE NOTE NO N NO N ND POWER SUPPLY SEE NOTE 08V / 0V - ph - 0Hz F F F F F F TB M M High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ALS RS GV S S G R Y Y W W O OOL HEAT L UNUSED L DI PS PLF M FS LS II Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. REPLAE JUMPER WITH SMOKE/FIRE DETET SEE NOTE FS IGN TO THERMOSTAT SEE NOTE 00L00-A SS-DG

24 Wiring Diagram DG & 0 Tons (0V Two-Speed Belt Drive) (cont.) SUPPLY VOLTAGE 08-0//0 L L L OMPONENT LEGEND T T T ALS AUXILLARY LIMIT SWITH T OMP T T B OWER ONTAT OWER RELAY B OMP IRUIT EAKER OMPRESS F F M M H ONDENSER MOT OMPRESS ONTAT RANK ASE HEATER F HR RANK ASE HEATER RELAY F R OMPRESS ONTAT RELAY M EM EVAPAT MOT F F F FUSE M F FAN APAIT L 9 F B B H H NOTE II B B EON H T 8 0 T HIGH SPEED HR HR FS D OMP T T EM LS PS ALS T V TR RS HPS LOW SPEED B B 08-0v B B R R T IGN B VMR FS B B B VMR LPS GV VM HPS LPS B B R L FS FLAME SENS EQUIPMENT OUND GV GAS VALVE HPS HIGH PRESSURE SWITH I INDO OWER RELAY II INTEATED IGNITION ONTROL IGN IGNIT LPS LOW PRESSURE SWITH LS LIMIT SWITH PB POWER DISTRUBTION OK PLF FEMALE PLUG/ONNET PS PRESSURE SWITH RS ROLLOUT SWITH TB TERMINAL OK (V SIGNAL) TB TERMINAL OK (L) TR TRANSFMER VM VENT MOT VMR VENT MOT RELAY NOTES. REPLAEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS IGINAL. (USE OPPER ONDUT ONLY).. AESSY EONOMIZER PLUG ADJAENT TO OWER HOUSING IN RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH FEMALE PLUG TO THE EONOMIZER AESSY.. L AND L ON II ONTROL IS V INT.. USE OPPER ONDUTS ONLY. USE NE LASS WIRE.. F TWO STAGE OPERATION REMOVE. F TWO STAGE OPERATION REMOVE W TO W WIRE JUMPER. W TO W WIRE JUMPER.. F 08V OPERATION MOVE AK WIRE FROM TERMINAL TO TERMINAL ON THE TRANSFMER. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. R THERMOSTAT S R S W Y W Y G O TO THERMOSTAT SEE NOTE TB STATUS LIGHT ON OFF INK INKS NOTE EQUIPMENT STATUS NMAL OPERATION NO POWER INTERNAL ONTROL IGNITION FAILURE OPEN ROLLOUT SWITH OPEN AUX. LIMIT SWITH HR INSTALLER/SERVIEMAN THE STATUS LIGHT ON THE FURNAE ONTROL MAY BE USED AS A GUIDE TO TROUESHOOTING THIS APPLIANE. STATUS LIGHT ODES ARE AS FOLLOWS: PRESSURE SWITH OPEN HR SEE NOTE 9 8 HEK HEK INT POWER HEK FUSE ON ONTROL REPLAE ONTROL GAS FLOW GAS PRESSURE GAS VALVE FLAME SENS FLAME ROLLOUT BAD SWITH AUX. LIMIT OPEN HEK PRESSURE SWITH FATY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE ODE AK UE OWN EEN ANGE PINK RPLE RED ITE YELLOW / YELLOW WITH FIELD WIRING STAGE OOLING W G R Y Y O TB W G R Y Y O STAT Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. INKS PRESSURE SWITH LOSED WITHOUT INDUER ON HEK PRESSURE SWITH PINK STRIP / UE WITH INKS OPEN LIMIT SWITH MAIN LIMIT OPEN BAD SWITH PINK STRIP INKS FALSE FLAME SENSED STIKING GAS VALVE INKS OMPRESS OUTT DELAY MIN. OMP. ANTI-YLE TIMER SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER URRENT PROTETION 00L09-A SS-DG

25 9 8 Wiring Diagram DG & 0 Tons (0V/ V Two-Speed Belt Drive) H HR OMP T T T T T T L L L PB HR VM SEE NOTE PLF HPS LPS H HPS LPS T OMP T T HIGH EM LOW VMR R R T T T T T T B HIGH SPEED L L L B LOW SPEED 0 APPROPRIATE INT VOLTAGE 0 L L L T T T T T T T T T L L L L L B L L L B L TR 0 V SEE NOTE NO N NO N ND POWER SUPPLY SEE NOTE 0V / V - ph - 0Hz F F F F F F TB M M High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 00L00-B ALS RS GV S S REPLAE JUMPER WITH SMOKE/FIRE DETET G R Y Y W W O TO THERMOSTAT ++ SEE NOTE SEE NOTE OOL HEAT L UNUSED L DI FS IGN PS 9 8 PLF 0 WIRING ODE FATY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE ++ USE N.E.. LASS WIRE M FS LS II OL ODE AK UE OWN ANGE RPLE RED ITE YELLOW PINK EEN Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. SS-DG

26 Wiring Diagram DG & 0 Tons (0V/ V Two-Speed Belt Drive) (cont.) L SUPPLY VOLTAGE 0///0 L L OMPONENT LEGEND T T OMP T T T T ALS B OMP AUXILLARY LIMIT SWITH OWER ONTAT OWER RELAY OMPRESS M ONDENSER MOT F F M H HR R OMPRESS ONTAT RANK ASE HEATER RANK ASE HEATER RELAY OMPRESS ONTAT RELAY F F EM F EVAPAT MOT FUSE M F F FAN APAIT F FS FLAME SENS NOTE L 9 F B B H H NOTE II II B B EON H T 8 0 T HIGH SPEED HR HR FS D OMP T T EM LS PS T 0V V ALS IGN FS TR T LOW SPEED B B B B R R RS B HPS VMR TR 0V V B B B VMR LPS GV M HPS LPS VM B B R L EQUIPMENT OUND GV GAS VALVE HPS HIGH PRESSURE SWITH I INDO OWER RELAY II INTEATED IGNITION ONTROL IGN IGNIT LPS LOW PRESSURE SWITH LS LIMIT SWITH PLF FEMALE PLUG/ONNET PS PRESSURE SWITH RS ROLLOUT SWITH TB TERMINAL OK (V SIGNAL) TB TERMINAL OK (L) TR TRANSFMER VM VENT MOT VMR VENT MOT RELAY NOTES. REPLAEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS IGINAL. (USE OPPER ONDUT ONLY).. AESSY EONOMIZER PLUG ADJAENT TO OWER HOUSING IN RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH FEMALE PLUG TO THE EONOMIZER AESSY.. L AND L ON II ONTROL IS V INT.. USE OPPER ONDUTS ONLY. USE NE LASS WIRE.. F TWO STAGE OPERATION REMOVE W TO W WIRE JUMPER. W TO W WIRE JUMPER. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. TB REPLAE JUMPER WITH SMOKE/FIRE DETET S S R G W W Y Y O STATUS LIGHT ON OFF INK INKS INKS INSTALLER/SERVIEMAN THE STATUS LIGHT ON THE FURNAE ONTROL MAY BE USED AS A GUIDE TO TROUESHOOTING THIS APPLIANE. STATUS LIGHT ODES ARE AS FOLLOWS: STATUS LIGHT ON OFF INK INKS INKS TO THERMOSTAT ++ SEE NOTE EQUIPMENT STATUS EQUIPMENT STATUS NMAL OPERATION NMAL OPERATION NO POWER INTERNAL ONTROL NO POWER INTERNAL ONTROL IGNITION FAILURE IGNITION FAILURE OPEN ROLLOUT SWITH OPEN ROLLOUT SWITH OPEN AUX. LIMIT SWITH OPEN AUX. LIMIT SWITH PRESSURE SWITH OPEN PRESSURE SWITH OPEN PRESSURE SWITH LOSED WITHOUT INDUER ON PRESSURE SWITH LOSED WITHOUT INDUER ON HR R HR 9 8 PLF NOTE HEK HEK HEK INT POWER HEK INT POWER HEK FUSE ON ONTROL HEK FUSE ON ONTROL REPLAE ONTROL REPLAE ONTROL GAS FLOW GAS FLOW GAS PRESSURE GAS PRESSURE GAS VALVE GAS VALVE FLAME SENS FLAME SENS FLAME ROLLOUT FLAME ROLLOUT BAD SWITH BAD SWITH AUX. LIMIT OPEN AUX. LIMIT OPEN HEK HEK PRESSURE SWITH PRESSURE SWITH HEK HEK PRESSURE SWITH PRESSURE SWITH FATY WIRING LINE VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE WIRE ODE AK UE OWN EEN ANGE PINK RPLE RED ITE YELLOW / YELLOW WITH PINK STRIP / UE WITH PINK STRIP THERMOSTAT FIELD WIRING STAGE OOLING W G R Y Y O TB NO EONOMIZER W G R Y Y O TB WITH EONOMIZER OPTION W G R Y Y O TB W G R Y Y O STAT W G R Y O STAT W G R Y O STAT Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. INKS INKS INKS INKS OPEN LIMIT SWITH OPEN LIMIT SWITH FALSE FLAME SENSED FALSE FLAME SENSED MAIN LIMIT OPEN BAD SWITH BAD SWITH STIKING GAS VALVE STIKING GAS VALVE INKS INKS OMPRESS OMPRESS OUTT DELAY OUTT DELAY MIN. OMP. MIN. OMP. ANTI-YLE TIMER ANTI-YLE TIMER SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER URRENT PROTETION 00L09-A SS-DG

27 Wiring Diagram DG Tons (0V/0V/V, Speed Belt Drive - ontrols Diagram) FIELD ONTROL WIRING LASS TB W W G R Y YI S S THERMOSTAT WIRING STAGE OOLING W W G G R R Y Y Y Y O O STAT TB SMOKE DETET 0 9 V A/D Y Y SENS R B AUX A Y Y SENS R 8 AUX B B 8 Y Y R B Y Y R B SEN SEN SMK DET OPTION SUPPLY (LINE) VOLTAGE TR VA TB R HPS LPS TB PLM PLF R MR EON EON SHRT PLF PLM FM FM EON PLM HPS LAM PLF PLM 8 9 PLF PLM PLF G LUG PLM LPS -t -t -t EON MODULE MAT AUX-I MAT O E- OAT OAT EXH AUX-O S-BUS S-BUS Y-I Y-O IAQ -0 Y-I IAQ OM Y-O IAQ V AT OM R AT V M M B LOW SPEED MAS OD ENTH EON AT B HIGH SPEED EON OPTION High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. A II V V OM GV LIMIT SW PRESSURE SW G IN PRESSURE SW R W IN Y IN OMP OUT OOL HEAT L L FS D L NOTES:. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE OPPER ONDUTS ONLY).. IF OPTIONAL EONOMIZER IS INSTALLED, REMOVE EON SHRT PLM AND ONNET EON PLM TO EON PLF.. TB LOW VOLTAGE TERMINAL OK. TERMINALS F VA PWR (,, WIRE) AND TERMINALS F VA OM ( WIRE).. ONNETIONS SHOWN ARE F -STAGE HEAT OPERATION. EN -STAGE OPERATION IS REQUIRED REMOVE JUMPER WIRE ONNETING W TO W ON TB.. IF OPTIONAL SMOKE DETET IS INSTALLED, REMOVE JUMPER WIRE ONNETING S TO S ON TB AND MAKE THE FOLLOWING WIRE ONNETIONS: WIRE TO S, WIRE TO TB (V/PWR), WIRE TO TB (V/OM). FS LAR VMR LS LAM LAT T T T. IF LOW AMBIENT KIT IS INSTALLED, ONNET WIRE FROM LAM- TO MR-. ALSO ONNET OM WIRES FROM LAT-T AND LAM - TO TB (V OM).. LAT ON/OFF TIME SETTINGS : ON - TIME (LEFT OLUMN) :,8 = ON OFF - TIME (RIGHT OLUMN) : 8 = ON ALL - OTHER DIP SWITHES = OFF PS ALS ONTROLS DIAAM DG00***(,,) V SPD EM PLF PLM RS -t LA M GV ND STG ST STG LOW AMB OPTION OM 00L0-A Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. SS-DG

28 WIRING DIAAMS F MODELS WITH DD ONTROLS For complete information and installation instructions for models with DD controls, see manual DK-DD-TGD-XXX 8 SS-DG

29 Wiring Diagram with DD DG080*/ DG0* 08-0, 0, / / 0 SP ontrol ONTROL WIRING DIAAM DG(80-0) ****V DD TB (LASS) AG (OMP IN) (OMP OUT) (OMP OUT) (OMP IN) SMK/EMG LINE VOLTAGE TR DAT TB T T T T (LASS) VA T PS ES XS DA S -t V BS DD (LASS) OM RLY HPS LPS RLY / / / / OM (OWER STAGE ) RLY RLY (HEAT ) RLY HPS LPS (HEAT ) RLY 8 / / / RLY 9 / RLY8 0 (V IN) OM-8 (EON PWR) OM-8 RSS 8 BI (EMER) BI (FAN PROV) LDS BI (OMP PRESS ) BI (OMP PRESS ) BI (RMT STRT/STP) FS BI (SHED) (BA R+ BI (FS) NET) SH BA NET BI8 T- EON PLF OAT -t (EON DMPR) AO OAH AO VA VOUT (D) (PWR) (EXF) AO (ALRM) AO O VA VOUT (D) (PWR) 0 AI (SUPPLY AIR TMP) TWISTED VA 9 AI SPTEMP (OAT) EXF NTL RLY PAIR (OM) (EON FB) TEMP 8 AI 0VD STPT OFFSET AI (OAH) G AI (O) AI (SP TMP) IAH AI (SP SLIDE ADJ) VA VOUT (D) AI8 (SP HUM) (PWR) A (ISOL ) A ALRM NTL RLY 0VD G VA (OWER STAGE ) B (LO SPD) HTR PLF HTR PLM B (HI SPD) High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. NOTES: II VA PWR F VA OM A GV OUT F TMP LMT OUT TMP LMT IN PRESS SW IN PRESS SW OUT 8 HEAT IN FLAME SENSE VA L PWR L L VA L OM L L VENT MTR D IGNIT HEAT 0 GV RS ST STG OM ND STG ALS LS PS FS VMR Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring.. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (AT LEAST 0 ). USE OPPER ONDUTS ONLY. USE N.E.. LASS WIRE F ALL LOW VOLTAGE FIELD ONNETIONS. IF OPTIONAL SMOKE DETET IS INSTALLED, REMOVE RED JUMPER WIRE ONNETIONS TB-XS TO TB-ES. DISHARGE AIR TEMPERATURE SENS SHIPPED WITH UNIT IN ONTROL BOX. INSTALL AND ONNET PER THE ATTAHED INSTRUTIONS/WIRING DIAAM. IF OPTIONAL EONOMIZER IS INSTALLED, ONNET EON PLF TO EONOMIZER. EONOMIZER PLUG LOATED IN THE RETURN AIR OMPARTMENT. SEE POWER DIAAM F ONTROL TRANSFMER (TR) HIGH VOLTAGE ONNETIONS. 00L08-A SS-DG 9

30 Wiring Diagram with DD DG080*/ DG0* 08-0 / / 0 SP Power LINE VOLTAGE L L L POWER WIRING DIAAM DG(80-0) **** DD II DIAGNOSTI INK ODES EQUIPMENT STATUS HEK STATUS LIGHT ON NMAL OPERATION HEK INT POWER NO POWER OFF HEK FUSE ON ONTROL INTERNAL ONTROL REPLAE ONTROL INK IGNITION FAILURE OPEN ROLLOUT SWITH OPEN AUX LIMIT SWITH GAS FLOW GAS PRESSURE GAS VALVE FLAME SENSER FLAME ROLLOUT BAD SWITH AUX.LIMIT OPEN INKS PRESSURE SWITH OPEN HEK PRESSURE SWITH INKS PRESSURE SWITH LOSED WITHOUT INDUER ON HEK PRESSURE SWITH L L L PB AS INKS OPEN LIMIT SWITH MAIN LIMIT OPEN BAD SWITH H INKS INKS FALSE FLAME SENSED OMPRESS OUTT DELAY STIKING GAS VALVE MIN. OMP. ANTI-YLE TIMER, TR VMR LINE VOLTAGE NOTES:. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE OPPER ONDUTS ONLY).. THE ONTROL TRANSFMER HAS MULTIPLE HIGH VOLTAGE TAPS. ENSURE WIRE ONNETIONS ARE RET F UNIT SUPPLY VOLTAGE RATING. 08/0V SUPPLY POWER UNITS ARE FATY ONNETED TO THE ONTROL TRANSFMER 0V TAP. MOVE WIRE ONNETION FROM 0V TAP TO 08V TAP EN 08V POWER SUPPLY IS USED.. SEE ONTROL DIAAM F ONTROL TRANSFMER LOW VOLTAGE ONNETIONS. OPTIONAL; B,B,B AND ASSOIATED WIRING IS PRESENT ONLY WITH -SPEED EVAPAT MOT.. USE OPPER ONDUTS ONLY. UNIT TERMINALS ARE NOT DESIGNED F OTHER ONDUTS. THE USE OF OTHER TYPE ONDUTS MAY AUSE DAMAGE TO THE UNIT.. SEE AESSY KIT LITERATURE F OPTIONAL ONVENIENE OUTLET WIRING DIAAM. AS II IGN VM IGN L L L L L L B B H T T T T T T L L L F F F B HIGH SPEED T T T B LOW SPEED L T L T L T ALS ALRM B BS BM B AS H F FS OMP O DAT DD EON EXF F FS GV HH HPS HVTB IAH II LS LDS LPS OAT OAH PB PLF PLM PS RS RSS SMK SP TEMP TB TR VM VMR L L L L L L T T T T T T F HVTB OMPONENT LEGEND AUXILIARY LIMIT SWITH ALARM OWER ONTAT OWER URRENT SWITH OWER MOT IRUIT EAKER OMPRESS ONTAT OMPRESS ONTAT AUXILIARY SWITH RANK ASE HEATER ONDENSER FAN LOGGED FILTER SWITH OMPRESS ARBON DIOXIDE SENS DISHARGE AIR TEMPERATURE SENS DIRET DIGITAL ONTROL EONOMIZER EXHAUST FAN FAN APAIT FLAME SENSE EQUIPMENT OUND GAS VALVE HOT GAS REHEAT HIGH PRESSURE SWITH HIGH VOLTAGE TERMINAL BOA INDO AIR HUMIDITY SENS INTEATED IGNITION ONTROL LIMIT SWITH LOAD SHEDDING LOW PRESSURE SWITH OUTDO AIR TEMPERATURE SENS OUTDO AIR HUMIDITY SENS POWER DISTRIBUTION OK FEMALE PLUG/ONNET MALE PLUG/ONNET PRESSURE SWITH ROLL-OUT SWITH REMOTE START/STOP SMOKE DETET SPAE TEMPERATURE SENS TERMINAL OK (V SIGNAL) TRANSFMER VENT MOT VENT MOT RELAY L L OMP L L L OMP L BM F F F FATY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL AESSIES FIELD SUPPLIED WIRE ODE AK UE OWN EEN AY ANGE PINK RPLE RED ITE YELLOW / YELLOW WITH PINK STRIPE / UE WITH PINK STRIPE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 00L08-A 0 SS-DG

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

DCH Commercial Contents Standard Features Cabinet Features

DCH Commercial Contents Standard Features Cabinet Features DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8

More information

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners D ommercial Standard Features R-410A chlorine- free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h DG ommercial ooling apacity: 88,000 116,000 BTU/h Heating apacity (Output): 144,000 BTU/h 7½- to 10-Ton Three-Phase Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE ontents Nomenclature... 2 Product Specifications...

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DG ommercial 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE ooling apacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h ontents Nomenclature... 2 Product Specifications... 4 Expanded ooling

More information

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...

More information

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h DP14HM ommercial ooling apacity: 34,400-58,000 BTU/h Heating apacity: 33,00-57,000 BTU/h 3-5 TON THREE-PHASE PAKAGED HEAT MPS 14 SEER ontents Nomenclature... Product Specifications...3 Expanded ooling

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE DT ommercial 5 Tons as/ Electric Units Up to 5.5 SEE and.0 EE Up to 8% AFUE ooling apacity: 5,600 60,000 BTU/h Heating apacity: 6,000 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded

More information

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical

More information

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h GP13M Packaged Air onditioner R-410A, 13 SEER ooling apacity: 36,000-56,000 BTU/h 3, 4, & 5 Tons Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor

More information

DCC Commercial Tons Packaged Air Conditioners

DCC Commercial Tons Packaged Air Conditioners DCC Commercial - Tons Packaged Air Conditioners Tons Cooling Capacity: 80,000 BTU/h 0 Tons Cooling Capacity: 0,000 BTU/h Tons Cooling Capacity: 90,000 BTU/h Contents Nomenclature... Product Specifications...

More information

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 11.3 EER

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 11.3 EER D ommercial Ton Packaged Air onditioner Up to. EER Two-Speed Blower Motor and Two-Stage ompressor Up to 5.5 IEER ooling apacity: Up to 7,000 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% AFUE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% AFUE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DG ommercial 6 Ton Packaged Gas/ Electric Units up to. IEER 80% AFUE ooling apacity: Up to 7,000 BTU/h Heating Input: 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

DP14GM Commercial 14 SEER / 81% AFUE 3-5 TON, THREE-PHASE PACKAGED GAS/ELECTRIC. Cooling Capacities: 34,200 to 57,000 BTU/h

DP14GM Commercial 14 SEER / 81% AFUE 3-5 TON, THREE-PHASE PACKAGED GAS/ELECTRIC. Cooling Capacities: 34,200 to 57,000 BTU/h DPGM ommercial ooling apacities:,00 to 7,000 BTU/h Heating apacities: 80,000 BTU/h to 0,000 BTU/h - TON, THREE-PHASE PAKAGED GAS/ELETRI SEER / 8% AUE ontents Nomenclature... Product Specifications... Expanded

More information

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency

More information

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP The new Goodman CPH Commercial Packaged Heat Pump features the environmentally friendly refrigerant R-410A, which is chlorine-free to help

More information

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...

More information

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H GP13M OMMERIAL PAKAGED AIR ONDITIONER PRODUT SPEIFIATIONS The Goodman GP13M ommercial Packaged Air onditioner features energy-efficient cooling and heating performance in one self-contained unit. This

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12

More information

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger GPG14M ooling apacity: 23,000 to 57,500 BTU/h Heating apacity: 40,000 to 120,000 BTU/h Packaged Gas / Electric Units 2 to 5 Tons 14 SEER / 81% AFUE ontents Nomenclature... 2 Product Specifications... 3

More information

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h PH ommercial ooling apacity: 5, 7, BU/h Heating apacity: 4,6 7, BU/h - to 6-on Packaged Heat Pump SEE / up to. EE & 7.7 HSPF Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor

More information

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower

More information

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h DX13S ommercial ooling apacity: 36,000-60,000 BTU/h 3-, 4-, & 5-Ton, Three-Phase Split System Air onditioner ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI Ratings...

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

DCG Commercial. 15- & 20-Ton, Three-Phase

DCG Commercial. 15- & 20-Ton, Three-Phase DG ommercial 5- & 0-Ton, Three-Phase Packaged Gas/Electric Standard eatures -0A chlorine-free refrigerant Patented tubular heat exchanger High-efficiency scroll compressor opper tube / aluminum fin coils

More information

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

DZ11S Commercial & 10-Ton, Three-Phase

DZ11S Commercial & 10-Ton, Three-Phase DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 Expanded Heating Data... 12 AHRI

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DCG Commercial 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h Contents Nomenclature... 2 Product Specifications... 4 Expanded

More information

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS 11.5 EER / 80% SSE THREE-PHASE COOLING CAPACITY: 118,000 BTU/H HEATING CAPACITY: 210,000 BTU/H CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS The new Goodman CPG Commercial Packaged Gas/

More information

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus DX11S ommercial 7.5- & 10-ton, Three-Phase Split System Air onditioner 11.2 EER / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Air onditioner with One Two-Speed Indoor Air Handler and Two 4-Ton

More information

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...

More information

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h DX13S ommercial Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper tube/ enhanced aluminum fin coil Service valves with sweat connections

More information

GPH13M. 13 SEER / R-410A 2 to 5 Tons

GPH13M. 13 SEER / R-410A 2 to 5 Tons ooling apacity: 24,000-56,000 BTU/h Heating apacity: 23,000-55,500 BTU/h GPH13M Packaged Heat Pump 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve

More information

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h Split System Air onditioner ooling apacity: 18,000-60,000 BTU/h 13 SEER / 1½ to 5 Tons Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper

More information

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ooling apacity: 18,000 to 60,000 Heating apacity: 18,000 to 60,000 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ontents Nomenclature... 2 Product Specifications... 3 Expanded

More information

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h DX18T ooling apacity: 34,600-58,000 BTU/h High-Efficiency, omfortnet -ompatible, Split System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data...

More information

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil Brass

More information

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 15.5 IEER. Cooling Capacity: Up to 71,000 BTU/h

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 15.5 IEER. Cooling Capacity: Up to 71,000 BTU/h DCC Commercial 6 Ton Packaged Air Conditioner Up to 15.5 IEER Cooling Capacity: Up to 71,000 BTU/h Contents Nomenclature... 2 Product Specifications... 4 Expanded Cooling Data... 5 Airflow Data... 7 Crankcase

More information

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h ooling apacity: 24,000-60,000 BTU/h High-Efficiency, omfortnet -ompatible, Split-System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI

More information

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H HIGH-EFFIIENY PRODUT SPEIFIATIONS SPLIT SYSTEM AIR ONDITIONER The Goodman Air onditioner uses the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone

More information

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h DSX18 ooling apacity: 34,000-56,000 BTU/h Split System Air onditioner up to 18 SEER Standard Features R-410A chlorine-free refrigerant Two-Stage opeland UltraTech scroll compressor High-density foam compressor

More information

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h ooling apacities: 23,600 to 57,000 TU/h Heating apacities: 46,000 to 138,000 TU/h GPG13M 2- to 5-Ton Packaged Gas/Electric Units 13 SEE / 80% AFUE ontents Nomenclature... 2... 3 Expanded ooling Data...

More information

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat

More information

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure

More information

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC GPG COMMERCIAL 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS The Goodman GPG Commercial Packaged Gas/ Electric 10 & 13 SEER units feature energy-efficient cooling and

More information

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A DZ14S Commercial Cooling Capacity: 34,600 to 56,500 BTU/h Heating Capacity: 32,800 to 59,000 BTU/h 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A Contents Nomenclature...2 Product Specifications...3

More information

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...

More information

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3

More information

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 5 Wiring Diagrams... 6

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 6 Wiring Diagrams... 0

More information

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant

More information

GSC13 Split System Air Conditioner

GSC13 Split System Air Conditioner Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

DC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 40,000-00,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 4 Airflow Specifications... 5 Wiring Diagram...

More information

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 10,000 BTU/h Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 5 Airflow Specifications... 7 Wiring Diagram...

More information

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.

More information

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps TEHNIAL MANUAL AL *SZ 16 SEER Split System Heat Pumps Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

GPG13 SINGLE-PHASE, SELF-CONTAINED

GPG13 SINGLE-PHASE, SELF-CONTAINED P1 SINLE-PHASE, SELF-ONTAINED PODUT SPEIFIATIONS 1 SEE/ 80% AFUE 2 5 TON OOLIN APAITIES: 24,000 TO 56,800 TU/H HEATIN APAITIES: 46,000 TO 18,000 TU/H PAKAED AS/ELETI The P1 Packaged as/electric Unit features

More information

GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A

GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A TEHNIAL MANUAL AL GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R410A Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. All safety information

More information

SSZ 14 SEER Split System Heat Pumps

SSZ 14 SEER Split System Heat Pumps TEHNIAL MANUAL AL SSZ 14 SEER Split System Heat Pumps Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.

More information

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

GCEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h GE96 Heating Input: 40,000 00,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 4 Airflow Specifications... 5 Wiring Diagrams...

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage Two-Stage, onvertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 140,000 BTU/h ontents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

AMEC96. Heating Input: 30, ,000 BTU/h

AMEC96. Heating Input: 30, ,000 BTU/h Heating Input: 30,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace up to 96% AFUE Standard Features Energy-efficient multi-speed EM blower motor Heavy-duty stainless-steel tubular heat exchanger Stainless-steel

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

DC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h

DC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h Heating Input: 46,000 5,000 BTU/h Standard Features Heavy-duty stainless-steel dual-diameter, tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage convertible gas valve automatically

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A TEHNIAL MANUAL AL *P 14 SEER R-410A Package Air onditioners with R-410A Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. All safety information

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TEHNIAL INFOMATION MANUAL SSZ 16 SEE Split System Heat Pumps Models listed on page 3 efer to Service Manual S6200005 for installation, operation, and troubleshooting information. All safety information

More information