DCC Commercial. 6 Ton Packaged Air Conditioner Up to 11.3 EER

Size: px
Start display at page:

Download "DCC Commercial. 6 Ton Packaged Air Conditioner Up to 11.3 EER"

Transcription

1 D ommercial Ton Packaged Air onditioner Up to. EER Two-Speed Blower Motor and Two-Stage ompressor Up to 5.5 IEER ooling apacity: Up to 7,000 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded ooling Data... 5 Airflow Data... 9 rankcase Heater... 0 Electrical Data / Heat Kit Data... Dimensions... 5 Wiring Diagrams... 9 for Models with DD ontrols Accessories Standard Features High-efficiency scroll compressor opper tube/aluminum fin coils High- and low-pressure switches ontactor with lugs High-capacity, steel-cased filter drier Heater kits with single-point entry 2-volt terminal strip onvertible airflow orientation Easy to service Built-in filter rack with standard 2" filters Bottom utility entry AHRI ertified; ETL Listed Single speed blower motor units meet the performance specified in Table.8.A of ASHRAE Standard Two-speed blower motor and two-stage compressor meet the performance specified as of //20 in Table.8.- of ASHRAE Standard abinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan * omplete warranty details available from your local distributor or manufacturer s representative or at SS-D 7/7 Supersedes /7

2 Nomenclature D B * * * A * 2,5, 7,8, Revision Levels Major & Minor Brand Factory-Installed Options D Daikin X No Options A Non-powered convenience outlet onfiguration B Powered convenience outlet Standard Efficiency ( - 25 Tons) Low-ambient kit S Standard Efficiency ( - 5 Tons) D Return air smoke detector T High Efficiency ( - 5 Tons) E Supply air smoke detector F Non-powered convenience outlet; Application Low-ambient kit ooling G Non-powered convenience outlet; G Gas Heat Return air smoke detector H Heat Pump H Non-powered convenience outlet; Supply air smoke detector Nominal ooling apacity J Non-powered convenience outlet; 0 Tons 02 8½ Tons Tons Return & Supply air smoke detectors 08 Tons 20 0 Tons K Non-powered convenience outlet; 00 5 Tons 50 2½ tons Low-ambient kit; Supply air smoke detector 072 Tons 80 5 Tons L Non-powered convenience outlet; 090 7½ Tons Tons Low-ambient kit Return & Supply air smoke detectors Nominal Heating apacity M Powered convenience outlet; Gas/Electric A/ H/P Factory-Installed Electric Heat Low-ambient kit 05 5,000 BTU/h XXX No Heat N Powered convenience outlet; ,000 BTU/h 00 0 kw 00 0 kw Return air smoke detector 5 5,000 BTU/h 05 5 kw 0 0 kw O Powered convenience outlet; 0 0,000 BTU/h 0 5 kw 05 5 kw Return & Supply air smoke detectors 20 20,000 BTU/h 08 8 kw 0 5 kw P Powered convenience outlet; 50 50,000 BTU/h kw 00 0 kw Supply air smoke detector 00 00,000 BTU/h kw Q Powered convenience outlet; Low-ambient See product specifications for heat size(s) available for each capacity. kit; Return air smoke detector R Powered convenience outlet; Low-ambient Voltage kit; Supply air smoke detector //0 0//0 T Powered convenience outlet; Low-ambient // //0 kit; Return & Supply air smoke detectors U Non-powered convenience outlet; Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detector B Belt Drive (single speed) V Two-Speed Belt Drive (also designates -Ton V Low-ambient kit; Return air smoke detector D Direct Drive (-5 Tons) with two-stage compressor) W Low-ambient kit; Supply air smoke detector H High Static (single-speed Belt Drive models only) Y Low-ambient kit; Return & Supply Factory-Installed Options air smoke detectors A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; Z Return & Supply air smoke detectors B DD-BAnet protocol DD-BAnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) DD-BAnet protocol V Low-Leak Downflow Economizer Factory-Installed Options H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer X Standard Aluminized Heat Exchanger J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) S Stainless-Steel Heat Exchanger Disconnect Switch (non-fused) X No Options D Hinged Panels M Disconnect Switch (non-fused); DD-BAnet protocol K Stainless-Steel Heat Exchanger; Hinged Panels Note: Not all options available for all products. B Phase Monitor X= No Options in character th J Stainless Steel Heat Exchanger; Phase Monitor M Hinged Panel; Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor 2 SS-D

3 Factory-Installed Options Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 09-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to -ton units, cooling operation is extended from 0 F ambient temperature to 5 F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 5 F ambient temperature to 0 F outside air temperature. For 25 ton units, cooling operation is extended from 2 F ambient temperature to 0 F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (A and heat pump units only): Available in all voltage options. Non-powered onvenience Outlet: A 20V, 5A, GFI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered onvenience Outlet: A 20V, 5A, GFI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.2A/.5A for 208/20V units, increase by.a for 0V units, and by 2.A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused; -phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DS units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. ombined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. Two-speed indoor fan blower models are available on, 7½, 8½, 0, 2½, 5, 20 & 25 ton units. Section...0.b of ASHRAE Standard and Section a of ASHRAE Standard require a minimum of two fan speeds. Section 0.(m) of alifornia Energy ommission Title 2 20 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is % of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. Phase Monitor: Phase monitor ( phase only), available for - 25 ton DS, D and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. DD ontroller: DD communicating controller, available for - 25 ton DS, D and DT series models with on-board BAnet communication interface. SS-D

4 Product Specifications Tons D072 ***B***A* D072 ***V***A* D072 ***B***A* D072 ***V***A* D072 ***7B***A* D072 ***7V***A* ooling apacity Total BTU/h 7,000 70,000 7,000 70,000 7,000 70,000 Sensible BTU/h 9,800 5,000 9,800 5,000 9,800 5,000 EER / IEER.2 /../5.5.2 /../5.5.2 /../5.5 Decibels AHRI Number Evaporator Motor / oil Motor Type Belt Drive 2-Speed Belt Drive Belt Drive 2-Speed Belt Drive Belt Drive 2-Speed Belt Drive Wheel (D x W) (" x 0") ( x 0 ) (" x 0") ( x 0 ) (" x 0") ( x 0 ) Indoor Nominal FM 2,50 2,250 2,50 2,250 2,50 2,250 Indoor Motor FLA (ooling) Horsepower - RPM.5-, ,725.5-, ,725.5-, ,725 Piston Size (ooling) 0.09 TXV 0.09 TXV 0.09 TXV Filter Size () " x 20" x 2" () " x 20" x 2" () " x 20" x 2" () " x 20" x 2" () " x 20" x 2" () " x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾" R-0A Refrigerant harge ir #(oz.) Evaporator oil Face Area (ft²) Rows Deep/ Fins per Inch / / / / / / Motor Sheave VL X 7/8 VL X 7/8 VL X 7/8 VL X 7/8 VL X 7/8 VL X 7/8 Blower Sheave AK59 X AK59 X AK59 X AK59 X AK59 X AK59 X Belt AX5 AX5 AX5 AX5 AX5 AX5 ondenser Fan / oil Quantity of condenser Fan Motors Horsepower - RPM ⅓ -,075 ⅓ -,075 ⅓ -,075 ⅓ -,075 ⅓ -,075 ⅓ -,075 Fan Diameter/ # Fan Blades 22/ 22/ 22/ 22/ 22/ 22/ Outdoor Nominal FM,200,200,200,200,200,200 Face Area (ft²) Rows Deep/ Fins per Inch 2 /27 2/ 27 2 /27 2 /27 2 /27 2 /27 ompressor Quantity / Type / Scroll / Scroll / Scroll / Scroll / Scroll / Scroll Stage Single Two Single Two Single Two ompressor RLA / LRA 9/2.0 7./ 9.7/ /. 7./50.0./55. Electrical Data Voltage/Phase/ Frequency 208/ / Quantity of ompressors Belt-Driven Standard Max Static Outdoor Fan FLA Total Unit Amps Min. ircuit Ampacity¹ 0. / 0. 0 / Max. Overcurrent Protection (amps)² 5 / 5 5 / Entrance Power Supply.25".25".25".25".25".25" Entrance ontrol Voltage ½" ½" ½" ½" ½" ½" Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Notes Always check the S&R plate for electrical data on the unit being installed. When a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.2A/.5A for208/20v units, increase by.a for 0V units, and by 2.A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. SS-D

5 Expanded ooling Data Tons - Single Speed Outdoor Ambient Temperature 5 F 75 F 85 F 95 F 05 F 5 F Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) SS-D 5

6 Expanded ooling Data Tons - Single Speed (cont.) Outdoor Ambient Temperature 5 F 75 F 85 F 95 F 05 F 5 F Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR MBh S/T T kw HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Ratings conditions kw = Total system power High and low pressures are measured at the liquid and suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) SS-D

7 Expanded ooling Data Tons - 2 Speed Outdoor Ambient Temperature 5 F 75 F 85 F 95 F 05 F 5 F Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High and low pressures are measured at the liquid and suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) SS-D 7

8 Expanded ooling Data Tons - 2 Speed (cont.) Outdoor Ambient Temperature 5 F 75 F 85 F 95 F 05 F 5 F Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Ratings conditions kw = Total system power High and low pressures are measured at the liquid and suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) 8 SS-D

9 Airflow Data Tons ESP (In W..) Standard Belt Drive and Two-Speed Standard Belt Drive At High Speed - Horizontal 0 Turns Turn 2 Turns Turns Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In W..) Standard Belt Drive and Two-Speed Standard Belt Drive At High Speed - Down Shot 0 Turns Turn 2 Turns Turns Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In W..) High-Static Belt Drive Horizontal 0 Turns Turn 2 Turns Turns Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In W..) High-Static Belt Drive Down Shot 0 Turns Turn 2 Turns Turns Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Note: Tables represent dry coil without filter; to compensate for filter, add 0.08" to be measured E.S.P. Air Flow Pressure Drop of Down Flow Economizer Airflow Pressure Drop of Downflow Economizer for to Ton Rofftop Units (00% Return Air) SF, in WG SS-D 9

10 rankcase Heater, High Efficiency MERV Air Filter Option High Efficiency MERV Air Filter Option 0.50 Flanders Pre Pleat M Air Velocity vs Resistance (Test Size: 2" x 2" x 2" High apacity) " Deep Resistance (in. w.g.) Air Velocity (FPM) Tonnage: Filter Nominal Size: Part Number: Order QTY: 2 x 2 x 2 00L0020 x 20 x 2 00L0020 5,, 7.5 x 20 x 2 00L (HP), 8.5, 0 X 2 X 2 00L x 25 x 2 00L , x 25 x 2 00L X 20 X 2 00L rankcase Heater Selection Table ompressor Voltage rankcase ZP/ZPS ompressor Diameter 20V 0V 575V Heater Watts - 5.5" 0R00002S 0R000S 0R0002S /7." 00L0007S 00L0008S 00L0009S L00020S 00L0002S 00L00022S 90 D*,DT* & DS* Tonnage ompressor Voltage 20V 0V 575V rankcase Heater Watts Ton 0R00002S 0R000S 0R0002S 0 Ton-2.5 Ton 00L0007S 00L0008S 00L0009S Ton** 00L0007S 00L0008S 00L0009S Ton 00L00020S 00L0002S 00L00022S 90 *Includes,G&H models. **If ompressor Diameter is 9. then use 25 Ton rankcase heaters. 0 SS-D

11 Electrical Data Model Number Electrical Rating ompressor ompressor ircuit ircuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat Optional Powered onvienience Outlet Unit Power Supply RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MA MOP / 0. 5 / 5 EHK / / /.0 5 / 5 EHK-5. / 5.0. / / / 0 EHK / / /.0 0 / 70 D072XXXB 208/ Standard - EHK / / / / Belt Drive / / / 50 EHK / / /.5.0 /. 50 / 50 EHK-5. / 5.0. /. 7.2 /.5 5. / / 0 EHK / / / / / 80 EHK / / / / / 90 D072XXXH 208/ D072XXXV 208/ D072XXXB D072XXXH D072XXXV D072XXX7B High Static - Belt Drive Standard - Belt Drive (High Speed) Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive (High Speed) Standard - Belt Drive / / 50 EHK / / / / 50 EHK-5. / 5.0. / / / 0 EHK / / / / 70 EHK / / / / /.5 9. / / 50 EHK / / /.5.0 /. 50 / 50 EHK-5. / 5.0. /. 7.2 /.5 5. /. 0 / 70 EHK / / / / / 80 EHK / / / / / / / 5 EHK / / / / 5 EHK-5. / 5.0. /. -. / / 0 EHK / / / / 70 EHK / / / / / /.5 50 / 50 EHK / / / / / 50 EHK-5. / 5.0. /. 7.2 / / / 70 EHK / / / / / 80 EHK / / /.5 8. / / EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK SS-D

12 Electrical Information (cont.) Model Number Electrical Rating ompressor ompressor ircuit ircuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat Optional Powered onvienience Outlet Unit Power Supply RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MA MOP EHK EHK EHK D072XXX7H High Static - EHK Belt Drive EHK EHK EHK EHK D072XXX7V Standard - Belt Drive (High Speed) * Electric heat kw rating: Rated at 208V/20V for 208V/20V units; 80V for 0V units; 575V for 575V units * Electric heat kits rated 20KW or lower are single stage; Electric heat kits larger than 20KW are two stage EHK EHK EHK EHK EHK EHK EHK EHK SS-D

13 Heat Kit Electrical Data (Blower Only, Heat Mode) Tons Model and Heat Kit Usage Recommended Airflow Range D072***B*** --- EHK-0 EHK-5 EHK-20 EHK-25 Model and Heat Kit Usage Recommended Airflow Range D072***B*** --- EHK-0 EHK-5 EHK-20 EHK-25 kw orrection Factor for -Phase Units Supply Voltage orrection Factor For other voltage use votlage 2 / 20 2 kw orrection Factor for 80V Units Actual Voltage orrection Factor For other voltage use voltage² / 80² kw orrection Factor for 575V Units Supply Voltage orrection Factor Multiply rated kw by correction factor to get actual kw. For other voltage use votlage 2 / Model and Heat Kit Usage Recommended Airflow Range D072***7B*** --- EHK7-0 EHK7-5 EHK7-20 EHK7-25 Note: All heaters have single-point entry kit SS-D

14 Heat Kit Electrical Data (Blower Only, Heat Mode) Tons (cont.) Model and Heat Kit Usage Recommended Airflow Range D072***V*** --- EHK-0 EHK-5 EHK-20 EHK-25 Model and Heat Kit Usage Recommended Airflow Range D072***V*** --- EHK-0 EHK-5 EHK-20 EHK-25 kw orrection Factor for -Phase Units Supply Voltage orrection Factor For other voltage use votlage 2 / 20 2 kw orrection Factor for 80V Units Actual Voltage orrection Factor For other voltage use voltage² / 80² kw orrection Factor for 575V Units Supply Voltage orrection Factor Multiply rated kw by correction factor to get actual kw. For other voltage use votlage 2 / Model and Heat Kit Usage Recommended Airflow Range D072***7V*** --- EHK7-0 EHK7-5 EHK7-20 EHK7-25 Note: All heaters have single-point entry kit SS-D

15 Dimensions TOP VIEW FLUE/VENT OUTLET OMBUSTION AIR INLET (GAS UNITS) GAS LINE ENTRANE 7.95 FRONT VIEW ALL DIMENSIONS GIVEN ARE IN INHES ALL DIMENSIONS AND SPEIFIATIONS ARE SUBJET TO HANGE WITHOUT NOTIE SUPPLY AIR DUT D072*** TON OMMERIAL ONDENSATE DRAIN OUTLET LIFTING SHAKLE HOLES BOTH SIDES AND ENDS 8.9 FK HOLES BOTH SIDES AND BOTH ENDS RIGHT END VIEW RETURN AIR DUT SS-D 5

16 Dimensions ONDENSATE DRAIN BOTTOM EXIT SUPPLY AIR DUT RETURN AIR DUT 7.0 BASE PAN VIEW (VIEWED FROM TOP) 7.98 LINE WIRE ENTRANE TSTAT WIRE ENTRANE LEFT END VIEW SS-D

17 Unit learances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 8" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit s fresh-air intake. 8" 8" 8" 8" Electrical Entrance Locations High-Voltage Entrance (Remove Plug) 2⅜ 0¼ Low-Voltage Entrance Low-Voltage Entrance ½ Dia. Power Thru the urb 7½ 7½ SS-D 7

18 Roof urb Installation Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 0. Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof urb Installation Instructions Manual. Refer to the Roof urb Installation Instructions for proper curb installation. urbing must be installed in compliance with the National Roofing ontractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. heck for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. orner & enter-of-gravity Locations 0 ondenser oil Return Evaporator oil Supply Unit Weights -Ton Weights orner Weight (A) 50 orner Weight (B) 90 orner Weight () 0 orner Weight (D) 70 Unit Shipping Weight 5 Unit Operating Weight 0 Note: Weights are calculated without accessories installed. ompressor 7 urb installations must comply with local codes and should follow the established guidelines of the National Roofing ontractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. heck for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. antilevered-type curbs are not available from the factory. ontractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow Down Shot duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. 8 SS-D

19 Wiring Diagram D072 (20/0/575V, Three Phase, Belt Drive) G EBTDR R K NO XFMR-R XFMR- K OM NOTE #2 N SPEED UP M M2 L L2 L F T T2 T B RF EM L L2 L SUPPLY VOLTAGE //0 T2 T T2 T T OMP T RF F M B B EM B V TR EBTDR 2V R G R EBTDR B EBTDR P L LPS F 5 HPS PLF2 5 2 S S2 O R W2 W Y2 Y G THERMOSTAT SEE NOTE # ++ PK 2 PLF NOTES: TR 2V OMPONENT LEGEND B M MR OMP D DFT EON EBTD EMR R EM F HPS HVDR LPS LVDR LVJB PB PLF RV RF TB TR 8 M T T T2 OMP OWER ONTAT ONTAT ONDENSER MOT ONDENSER MOT RELAY OMPRESS DEFROST ONTROL DEFROST THERMOSTAT EONOMIZER ELETRONI OWER TIME DELAY EVAPAT MOT RELAY RELAY EVAPAT MOT FAN APAIT EQUPIMENT OUND HIGH PRESSURE SWITH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNTION BOX POWER DISTRUBTION OK FEMALE PLUG / ONNET REVERSING VAVLE OIL RUN APAIT F OMPRESS AND FAN TERMINAL OK (2V SIGNAL) TRANSFMER. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS IGINAL (AT LEAST 05 ) USE OPPER ONDUT ONLY. 2. USE OPPER ONDUTS ONLY ++ USE N.E.. LASS 2 WIRE. EONOMIZER PLUG LOATED IN THE RETURN AIR OMPARTMENT, REMOVE MALE PLUG, ATTAH FEMALE PLUG TO THE EONOMIZER AESSY.. F 208 VOLT TRANSFMER OPERATION MOVE AK WIRES FROM TERMINAL TO TERMINAL 2 ON TRANSFMER. SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER URRENT PROTETION //0 00L0500-A T L L 0 - T2 L2 L2 T L L 0 SEE - NOTE #2 5 7 /PK 5 / / PLF LVJB T Y H Y2 E R R G M W O S W2 T A O T S2 PK S ONTROL BOX ++ /PK LPS /PK HPS SMOKE/FIRE DETET REPLAES JUMPER AK UE OWN EEN ANGE PK PINK RPLE RED ITE YELLOW FATY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE ODE /PK UE WITH PINK STRIP /PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO EONOMIZER W G R W G R Y Y2 Y O O TB STAT WITH EONOMIZER OPTION W G R W G R Y Y Y2 O O TB STAT 2 STAGE OOLING W G R W G R Y Y Y2 PK Y2 O O TB STAT 8 7 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. SS-D 9

20 ONTROLS DIAAM D072 2 SPEED EM 2 STAGE OMP Wiring Diagram D ontrols Diagram D072-2 Speed (All Voltages) FIELD ONTROL WIRING LASS 2 5 LASS 2 FIELD ONTROL WIRING G W W2 Y Y2 O TB TB TB S S2 R TR SUPPLY (LINE) VOLTAGE TB 2 VA EBTDR R XFMR-R G XFMR- NO N OM SPEED-UP /PK HPS /PK /PK LPS /PK B B2 PLF S EON PLF EON SHRT PLM G EON PLM OPTIONAL EONOMIZER 2 PK MAT 2 AUX2-I PK MAT 2 O OAT E- OAT 5 EXH S-BUS S-BUS 2 AUX-O Y2-I IAQ Y2-O IAQ OM Y-I IAQ 2V Y-O AT OM 5 AT 2V 2 R MAS -t ENTH EON AT S-BUS S-BUS 2 2V-OM 2V-PWR PK OPTIONAL SMOKE DETET V A/D 9 0 AUX A AUX B SENS SENS 2 PK Y Y R B Y Y R B Y Y R B Y Y R B 5 SEN SEN2. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE OPPER ONDUTS ONLY). 2 IF OPTIONAL EONOMIZER IS INSTALLED, REMOVE EON SHRT PLM AND ONNET EON PLM TO EON PLF. TB LOW VOLTAGE TERMINAL OK. TERMINALS F (+)2VA-PWR (, WIRE),AND TERMINALS F (-) 2VA-OM ( WIRE). ONNETIONS SHOWN ARE F -STAGE HEAT OPERATION. EN 2-STAGE OPERATION IS REQIRED REMOVE JUMPER WIRE ONNETING W2 TO W ON TB. 5 IF OPTIONAL SMOKE DETET(S) ARE INSTALLED, REMOVE JUMPER WIRE ONNETING S TO S2 ON TB. WIRE ONNETIONS FROM AESSY KIT: ONNET WIRE TO TB-S. ONNET WIRE TO TB-S2. ONNET TO TB,(2 OM). EBTDR: FAN ENERGIZED 7 SE AFTER 2V APPLIED TO "G". FAN DE-ENERGIZED 5 SE AFTER 2V REMOVED FROM "G". IF SPEED-UP TERMINAL IS SHTED TO OUND ALL DELAYS ARE REDUED TO ~5 SE. 7 PLF ONNET F OPTIONAL ELETRI HEAT. SEE ELETRI HEAT SHEMATI F WIRING ONNETIONS. 00L098-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death SS-D

21 Wiring Diagram D Power Diagram D072-2 Speed (All Voltages) LINE VOLTAGE L L2 L POWER DIAAM D072 2 SPEED EM 2 STAGE OMP FATY WIRING HIGH VOLTAGE OPTIONAL HIGH VOLTAGE LOW VOLTAGE B OMP M S OMPONENT LEGEND OWER ONTAT OWER RELAY OMPRESS ONTAT OMPRESS ONDENSER MOT OMPRESS 2ND STAGE SOLENOID FIELD WIRING EBTDR EVAPAT OWER TIME DELAY RELAY EON EONOMIZER L T L2 T2 L T B L T F (2) 7 T T2 T OMP M HIGH VOLTAGE LOW VOLTAGE WIRE ODE AK UE OWN EEN GY AY ANGE PK PINK RPLE RED ITE YELLOW /PK UE/ PINK STRIPE /PK YELLOW/ PINK STRIPE EM F HPS LPS PLF PLM TB TB TR EVAPAT MOT FAN APAIT EQUPIMENT OUND HIGH PRESSURE SWITH LOW PRESSURE SWITH PLUG / ONNET, FEMALE PLUG / ONNET, MALE TERMINAL OK, LOW VOLTAGE TERMINAL OK, LOW VOLTAGE TRANSFMER, ONTROLS (LINE VOLTAGE / 2VA) THERMOSTAT ONNETIONS THERMOSTAT TB IN / OUT ONNETION 2VA-PWR (INT) R 2VA - OM (INT) FAN ALL G (OUTT) ST STAGE HEAT ALL W (OUTT) 2ND STAGE HEAT ALL W2 (OUTT) L2 T2 () ST STAGE OOL ALL (OUTT) Y L T () 2ND STAGE OOL ALL (OUTT) Y2 B2 EM L T L2 T2 GY GY L T 2V NTL VOLTAGE TR 2, LINE VOLTAGE NOTES:. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE OPPER ONDUTS ONLY). UNIT TERMINALS ARE NOT DESIGNED F OTHER ONDUTS THE USE OF OTHER TYPE ONDUTS MAY AUSE DAMAGE TO THE UNIT 2 THE ONTROL TRANSFMER HAS MULTIPLE HIGH VOLTAGE TAPS. ENSURE WIRE ONNETIONS ARE RET F UNIT SUPPLY VOLTAGE RATING 208/20V SUPPLY POWER UNITS ARE FATY ONNETED TO THE ONTROL TRANSFMER 20V TAP. MOVE WIRE ONNETION FROM 20V TAP TO 208V TAP EN 208V POWER SUPPLY IS USED. SEE ONTROL DIAAM F ONTROL TRANSFMER LOW VOLTAGE ONNETIONS 5. SEE AESSY KIT LITERATURE F OPTIONAL ONVENIENE OUTLET WIRING DIAAM. 2 SPEED EVAPAT MOT: AK LEADS F HIGH SPEED OPERATION, AND ITE / UE / ANGE LEADS F LOW SPEED OPERATION. 7 ONDENSER WIRING SHOWN F (208/20)V MODELS. WIRE TO WIRE ONNETIONS NOT PRESENT ON (0/575)V MODELS. THE ONDENSER MOT LEADS ONNET DIRETLY TO FAN APAIT / OMPRESS ONTAT. 00L0975-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-D 2

22 WIRING DIAAMS F MODELS WITH DD ONTROLS For complete information and installation instructions for models with DD controls, see manual DK-DD-TGD-XXX 22 SS-D

23 7 L 208 TR 0 2V TR2 T2 L2 2V T L SMK/EMG B PK BI BPSW BI2 HPS / / LPS /PK BI PK PK RSS BI BI5 LDS BI FS BI7 OM RL RL2 OM2 RL RL RL5 RL RL7 RL8 AO Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. EM OMP M T L T2 L2 PK POWER SUPPLY 208/20/0/575//0 SEE NOTE 2 T L SEE NOTE 2V TB T SEE NOTE 5 T2 T T T5 S PS ES XS PK BI8 OM-8 PK OM-8 DAT OAT AI AI2 AI AI AI5 + HH + EXF TB2 AG AI AI7 AI8 A A 2VA + ALRM HEATER PLF Wiring Diagram with DD D072***(208-20V,0V,575V//0) B*** T VOUT D 2VA OM DA /PK AO AO2 AO 2 VA VOUT D OARH TEMP STPT OFFSET SPRH SPTEMP VOUT D 2 5 EON RF F /0/575//0 00L050-B O2 SS-D 2

24 F Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. OMPONENT LEGEND NOTES:. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS IGINAL (AT LEAST 05 ) USE OPPER ONDUT ONLY. 2. USE OPPER ONDUTS ONLY ++ USE N.E.. LASS 2 WIRE. EONOMIZER PLUG LOATED IN THE RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH FEMALE PLUG TO THE EONOMIZER AESSY.. F 208/0 VOLT TRANSFMER OPERATION MOVE AK WIRE FROM TERMINAL TO TERMINAL 2 ON TRANSFMER. 5. REMOVE JUMPER IF SMOKE DETET EMERGENY SHUTDOWN DEVIE IS INSTALLED.. RANKASE HEATER AND RANKASE HEATER SWITH FATY EQUIPPED EN REQUIRED. SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER URRENT PROTETION High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. FATY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE WIRE ODE AK UE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE OWN EEN ANGE PK PINK RPLE RED ITE YELLOW /PK UE WITH PINK STRIP /PK YELLOW WITH PINK STRIP FIELD SPLIE IGNITER PLUG ONNETION SWITH (PRESS.) SWITH (TEMP) TERMINAL /0/575//0 A AO AI ALRM B B BHS BI S BPSW R F F FS H HS M OM OMP S DFT EON EM ES EXF HH HPS LDS LPS OAT OARH PLF PS RF RL RSS RV SAT/DAT SMK/EMG SPTEMP SPRH T-T5 TB-2 TR-2 XS D OUND F ANALOG SENSS ("AG" ON TB2) ANALOG OUTTS 8 ANALOG INTS ALARM OWER ONTAT OWER ONTAT OWER HIGH SPEED 8 BINARY INTS OWER LOW SPEED OWER PROVING SWITH ONTAT OMPRESS ONTAT OMPRESS ONTAT RELAY ONDENS FAN ONDENS FAN ONTAT LOGGED FILTER SWITH RANKASE HEATER RANKASE HEATER SWITH ONDENSER MOT OMMON ("" ON TB2) OMPRESS OM AND SMOKE DETET DEFROST THERMOSTAT EONOMIZER EVAPAT MOT EON OM-8,BI AND SMOKE DETET EXHAUST FAN EQUIPMENT OUND HOT GAS REHEAT HIGH PRESSURE SWITH LOAD SHEDDING LOW PRESSURE SWITH OUTDO AIR TEMPERATURE OUTDO AIR RELATIVE HUMIDITY FEMALE PLUG / ONNET HPS, LPS & SMOKE DETET RUN APAIT F ONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE OIL SUPPLY / DISHARGE AIR TEMPERATURE SMOKE EMERGENY SHUTDOWN SPAE TEMPERATURE SPAE RELATIVE HUMIDITY MOT SPEED TAPS -5 (DIRET DRIVEN MOT ONLY) TERMINAL OK (2V SIGNAL) TRANSFMER 2 VA TRANSFMER & SMOKE DETET L SEE NOTE 2 SUPPLY VOLTAGE /0/575//0 T2 T OMP L L2 T RF SEE NOTE M HS H B B EM B SEE NOTE 208/20/0/575//0 208/20/0/575//0 2 2 TR TR SEE NOTE 5 2V 2V SMK/EMG BPSW HPS LPS BI BI2 OM R BI RL BI RL2 RSS LDS FS OM2 BI5 B/S RL BI DD RL BI7 BI8 DAT AI OAT AI2 AI RL5 RL RL7 RL8 OARH O2 SENS SP OFFSET TEMP OM SPRH AI AI5 AI AI7 AI8 A OM-8 AO AO2 AO AO + HH + EXF ALRM 2VA EON PLF 2 5 HEATER PLF SHEMATI SYMBOL FIELD OUND INTERNAL TO INTEATED ONTROL JUNTION OVERURRENT PROT. DEVIE 00L055-B Wiring Diagram with DD D072***(208-20V,0V,575V//0)B*** 2 SS-D

25 7 Wiring Diagram With DD - D072***(208-20, 0, 575//0)V*** 208 TR 0 2V TR2 2V SEE NOTE SMK/EMG POWER SUPPLY 208/20/0/575//0 SEE NOTE 2 L B 2V T T2 T T T5 S PS ES XS DA PK PK TB SEE NOTE 5 DAT OAT PK BI BPSW BI2 HPS / / LPS /PK BI PK PK RSS BI BI5 LDS FS BI BI7 BI8 AI AI2 AI AI AI5 OM RL RL2 OM2 RL RL RL5 RL RL7 RL8 OM-8 OM-8 AO AO2 AO AO PK + HH + EXF TB2 AG AI AI7 AI8 A A 2VA + ALRM HEATER PLF Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. OMP F M EM VOUT D 2VA OM OUT PHASE MONIT L L2 L T L2 T2 L T L T L2 T2 L T /PK B2 L T L2 T2 L T 2 VA VOUT D SPRH OARH TEMP STPT OFFSET SPTEMP VOUT D 2 5 EON T2 T T S GY /0/575//0 00L07-A Y Y O2 SS-D 25

26 Wiring Diagram With DD - D072***(208-20, 0, 575//0)V*** F Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. OMPONENT LEGEND NOTES:. REPLAEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS IGINAL (AT LEAST 05 ) USE OPPER ONDUT ONLY. 2. USE OPPER ONDUTS ONLY ++ USE N.E.. LASS 2 WIRE. EONOMIZER PLUG LOATED IN THE RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH FEMALE PLUG TO THE EONOMIZER AESSY.. F 208/0 VOLT TRANSFMER OPERATION MOVE AK WIRE FROM TERMINAL TO TERMINAL 2 ON TRANSFMER. 5. REMOVE JUMPER IF SMOKE DETET/EMERGENY SHUTDOWN DEVIE PHASE MONIT IS INSTALLED.. RANKASE HEATER AND RANKASE HEATER SWITH FATY EQUIPPED EN REQUIRED. SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER URRENT PROTETION High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. FATY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE WIRE ODE AK UE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE OWN EEN ANGE PK PINK RPLE RED ITE YELLOW /PK UE WITH PINK STRIP /PK YELLOW WITH PINK STRIP FIELD SPLIE IGNITER PLUG ONNETION SWITH (PRESS.) SWITH (TEMP) TERMINAL /0/575//0 A AO AI ALRM B B2 BI BPSW S F F FS H HS M OM OMP DFT EON EM ES EXF HH HPS LDS LPS OAT OARH PLF PS RF RL RSS RV SAT/DAT SD SMK/EMG SPTEMP SPRH TB-2 TB-T TR-2 XS PM D OUND F ANALOG SENSS ("AG" ON TB2) ANALOG OUTTS 8 ANALOG INTS ALARM HIGH SPEED ONTAT LOW SPEED ONTAT 8 BINARY INTS OWER PROVING SWITH OMPRESS ONTAT OMPRESS 2ND STAGE SOLENOID ONDENS FAN ONDENS FAN ONTAT/OIL LOGGED FILTER SWITH RANKASE HEATER RANKASE HEATER SWITH ONDENSER MOT OMMON ("" ON TB2) OMPRESS DEFROST THERMOSTAT EONOMIZER EVAPAT MOT EON OM-8,BI AND SMOKE DETET EXHAUST FAN EQUIPMENT OUND HOT GAS REHEAT HIGH PRESSURE SWITH LOAD SHEDDING LOW PRESSURE SWITH OUTDO AIR TEMPERATURE OUTDO AIR RELATIVE HUMIDITY FEMALE PLUG / ONNET PRESSURE SWITH RUN APAIT F ONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE OIL SUPPLY / DISHARGE AIR TEMPERATURE SMOKE DETET SMOKE EMERGENY SHUTDOWN SPAE TEMPERATURE SPAE RELATIVE HUMIDITY TERMINAL OK (2V SIGNAL) PHASE MONIT TERMINAL (PM) TRANSFMER 2 VA TRANSFMER & SMOKE DETET PHASE MONIT L SEE NOTE 2 SUPPLY VOLTAGE /0/575//0 T OMP T2 T L2 L RF SEE NOTE M HS H B2 B2 B2 B EM B B SEE NOTE 208/20/0/575//0 208/20/0/575//0 2 2 TR TR 2V 2V SEE NOTE 5 SMK/EMG SD PM BPSW HPS LPS BI BI2 OM BI RL S BI RL2 RSS LDS FS OM2 BI5 B2 RL BI B DD RL BI7 BI8 DAT AI OAT AI2 AI RL5 RL RL7 RL8 OARH O2 SP TEMP OM SENS OFFSET SPRH AI AI5 AI AI7 AI8 A OM-8 AO AO2 AO AO + HH + EXF ALRM 2VA EON PLF 2 5 HEATER PLF SHEMATI SYMBOL FIELD OUND INTERNAL TO INTEATED ONTROL JUNTION OVERURRENT PROT. DEVIE 00L08-A SS-D

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

DCH Commercial Contents Standard Features Cabinet Features

DCH Commercial Contents Standard Features Cabinet Features DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h DP14HM ommercial ooling apacity: 34,400-58,000 BTU/h Heating apacity: 33,00-57,000 BTU/h 3-5 TON THREE-PHASE PAKAGED HEAT MPS 14 SEER ontents Nomenclature... Product Specifications...3 Expanded ooling

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase

More information

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18

More information

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners D ommercial Standard Features R-410A chlorine- free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DG ommercial 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE ooling apacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h ontents Nomenclature... 2 Product Specifications... 4 Expanded ooling

More information

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs

More information

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h GP13M Packaged Air onditioner R-410A, 13 SEER ooling apacity: 36,000-56,000 BTU/h 3, 4, & 5 Tons Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor

More information

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h DG ommercial ooling apacity: 88,000 116,000 BTU/h Heating apacity (Output): 144,000 BTU/h 7½- to 10-Ton Three-Phase Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE ontents Nomenclature... 2 Product Specifications...

More information

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE DT ommercial 5 Tons as/ Electric Units Up to 5.5 SEE and.0 EE Up to 8% AFUE ooling apacity: 5,600 60,000 BTU/h Heating apacity: 6,000 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H GP13M OMMERIAL PAKAGED AIR ONDITIONER PRODUT SPEIFIATIONS The Goodman GP13M ommercial Packaged Air onditioner features energy-efficient cooling and heating performance in one self-contained unit. This

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12

More information

DCC Commercial Tons Packaged Air Conditioners

DCC Commercial Tons Packaged Air Conditioners DCC Commercial - Tons Packaged Air Conditioners Tons Cooling Capacity: 80,000 BTU/h 0 Tons Cooling Capacity: 0,000 BTU/h Tons Cooling Capacity: 90,000 BTU/h Contents Nomenclature... Product Specifications...

More information

DCG Commercial Tons Packaged Gas / Electric Units

DCG Commercial Tons Packaged Gas / Electric Units DG ommercial - Tons Packaged Gas / Electric Units Tons ooling apacity: 80,000 BTU/h 0 Tons ooling apacity: 0,000 BTU/h Tons ooling apacity: 90,000 BTU/h Tons Heating apacity: 0,000 BTU/h 0 Tons Heating

More information

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP The new Goodman CPH Commercial Packaged Heat Pump features the environmentally friendly refrigerant R-410A, which is chlorine-free to help

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% AFUE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% AFUE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DG ommercial 6 Ton Packaged Gas/ Electric Units up to. IEER 80% AFUE ooling apacity: Up to 7,000 BTU/h Heating Input: 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h PH ommercial ooling apacity: 5, 7, BU/h Heating apacity: 4,6 7, BU/h - to 6-on Packaged Heat Pump SEE / up to. EE & 7.7 HSPF Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor

More information

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 15.5 IEER. Cooling Capacity: Up to 71,000 BTU/h

DCC Commercial. 6 Ton Packaged Air Conditioner Up to 15.5 IEER. Cooling Capacity: Up to 71,000 BTU/h DCC Commercial 6 Ton Packaged Air Conditioner Up to 15.5 IEER Cooling Capacity: Up to 71,000 BTU/h Contents Nomenclature... 2 Product Specifications... 4 Expanded Cooling Data... 5 Airflow Data... 7 Crankcase

More information

DZ11S Commercial & 10-Ton, Three-Phase

DZ11S Commercial & 10-Ton, Three-Phase DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 Expanded Heating Data... 12 AHRI

More information

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency

More information

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...

More information

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h

DCG Commercial. 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE. Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h DCG Commercial 6 Ton Packaged Gas/ Electric Units up to 15.5 IEER 80% TE Cooling Capacity: Up to 71,000 BTU/h Heating Input: 138,000 BTU/h Contents Nomenclature... 2 Product Specifications... 4 Expanded

More information

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h DX13S ommercial ooling apacity: 36,000-60,000 BTU/h 3-, 4-, & 5-Ton, Three-Phase Split System Air onditioner ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI Ratings...

More information

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger GPG14M ooling apacity: 23,000 to 57,500 BTU/h Heating apacity: 40,000 to 120,000 BTU/h Packaged Gas / Electric Units 2 to 5 Tons 14 SEER / 81% AFUE ontents Nomenclature... 2 Product Specifications... 3

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

DP14GM Commercial 14 SEER / 81% AFUE 3-5 TON, THREE-PHASE PACKAGED GAS/ELECTRIC. Cooling Capacities: 34,200 to 57,000 BTU/h

DP14GM Commercial 14 SEER / 81% AFUE 3-5 TON, THREE-PHASE PACKAGED GAS/ELECTRIC. Cooling Capacities: 34,200 to 57,000 BTU/h DPGM ommercial ooling apacities:,00 to 7,000 BTU/h Heating apacities: 80,000 BTU/h to 0,000 BTU/h - TON, THREE-PHASE PAKAGED GAS/ELETRI SEER / 8% AUE ontents Nomenclature... Product Specifications... Expanded

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

GPH13M. 13 SEER / R-410A 2 to 5 Tons

GPH13M. 13 SEER / R-410A 2 to 5 Tons ooling apacity: 24,000-56,000 BTU/h Heating apacity: 23,000-55,500 BTU/h GPH13M Packaged Heat Pump 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve

More information

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h DX13S ommercial Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper tube/ enhanced aluminum fin coil Service valves with sweat connections

More information

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree

More information

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...

More information

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS 11.5 EER / 80% SSE THREE-PHASE COOLING CAPACITY: 118,000 BTU/H HEATING CAPACITY: 210,000 BTU/H CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS The new Goodman CPG Commercial Packaged Gas/

More information

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus DX11S ommercial 7.5- & 10-ton, Three-Phase Split System Air onditioner 11.2 EER / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Air onditioner with One Two-Speed Indoor Air Handler and Two 4-Ton

More information

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or

More information

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h Split System Air onditioner ooling apacity: 18,000-60,000 BTU/h 13 SEER / 1½ to 5 Tons Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper

More information

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil Brass

More information

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ooling apacity: 18,000 to 60,000 Heating apacity: 18,000 to 60,000 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ontents Nomenclature... 2 Product Specifications... 3 Expanded

More information

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A DZ14S Commercial Cooling Capacity: 34,600 to 56,500 BTU/h Heating Capacity: 32,800 to 59,000 BTU/h 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A Contents Nomenclature...2 Product Specifications...3

More information

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h ooling apacities: 23,600 to 57,000 TU/h Heating apacities: 46,000 to 138,000 TU/h GPG13M 2- to 5-Ton Packaged Gas/Electric Units 13 SEE / 80% AFUE ontents Nomenclature... 2... 3 Expanded ooling Data...

More information

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized

More information

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h DX18T ooling apacity: 34,600-58,000 BTU/h High-Efficiency, omfortnet -ompatible, Split System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data...

More information

DCG Commercial. 15- & 20-Ton, Three-Phase

DCG Commercial. 15- & 20-Ton, Three-Phase DG ommercial 5- & 0-Ton, Three-Phase Packaged Gas/Electric Standard eatures -0A chlorine-free refrigerant Patented tubular heat exchanger High-efficiency scroll compressor opper tube / aluminum fin coils

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h ooling apacity: 24,000-60,000 BTU/h High-Efficiency, omfortnet -ompatible, Split-System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat

More information

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h DSX18 ooling apacity: 34,000-56,000 BTU/h Split System Air onditioner up to 18 SEER Standard Features R-410A chlorine-free refrigerant Two-Stage opeland UltraTech scroll compressor High-density foam compressor

More information

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC GPG COMMERCIAL 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS The Goodman GPG Commercial Packaged Gas/ Electric 10 & 13 SEER units feature energy-efficient cooling and

More information

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H HIGH-EFFIIENY PRODUT SPEIFIATIONS SPLIT SYSTEM AIR ONDITIONER The Goodman Air onditioner uses the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone

More information

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...

More information

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

GPG13 SINGLE-PHASE, SELF-CONTAINED

GPG13 SINGLE-PHASE, SELF-CONTAINED P1 SINLE-PHASE, SELF-ONTAINED PODUT SPEIFIATIONS 1 SEE/ 80% AFUE 2 5 TON OOLIN APAITIES: 24,000 TO 56,800 TU/H HEATIN APAITIES: 46,000 TO 18,000 TU/H PAKAED AS/ELETI The P1 Packaged as/electric Unit features

More information

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3

More information

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant

More information

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps TEHNIAL MANUAL AL *SZ 16 SEER Split System Heat Pumps Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 10,000 BTU/h Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 5 Airflow Specifications... 7 Wiring Diagram...

More information

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

GSC13 Split System Air Conditioner

GSC13 Split System Air Conditioner Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage Two-Stage, onvertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 140,000 BTU/h ontents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

SSZ 14 SEER Split System Heat Pumps

SSZ 14 SEER Split System Heat Pumps TEHNIAL MANUAL AL SSZ 14 SEER Split System Heat Pumps Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

ARUF Series Multi-Position

ARUF Series Multi-Position Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.

More information

GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A

GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A TEHNIAL MANUAL AL GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R410A Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. All safety information

More information

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant

More information

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 5 Wiring Diagrams... 6

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TEHNIAL INFOMATION MANUAL SSZ 16 SEE Split System Heat Pumps Models listed on page 3 efer to Service Manual S6200005 for installation, operation, and troubleshooting information. All safety information

More information

GSZ/VSZ 13 SEER Split System Heat Pumps

GSZ/VSZ 13 SEER Split System Heat Pumps TEHNIAL MANUAL AL GSZ/VSZ 13 SEER Split System Heat Pumps Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A TEHNIAL MANUAL AL *P 14 SEER R-410A Package Air onditioners with R-410A Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. All safety information

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 6 Wiring Diagrams... 0

More information

DC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h

DC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h Heating Input: 46,000 5,000 BTU/h Standard Features Heavy-duty stainless-steel dual-diameter, tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage convertible gas valve automatically

More information

DC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 40,000-00,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 4 Airflow Specifications... 5 Wiring Diagram...

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information