Series 858, Relay Sockets with Industrial Relay
|
|
- Elwin Osborne
- 5 years ago
- Views:
Transcription
1 Series 858, Relay Sockets with Industrial Relay voltage: V DC 4 changeover contacts voltage: V DC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact , for DIN 35 rail voltage V DC V DC Rated Power 0.9 W 0.9 W Current 36.9 ma 36.9 ma Holding Voltage 50% of V N 50% of V N Release Voltage 0.1 x V 0.1 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in
2 Series 858, Relay Sockets with Industrial Relay voltage: 0 V AC 4 changeover contacts voltage: 0 V AC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact., for DIN 35 rail voltage 0 V AC 0 V AC Rated Power 1.2 VA 1.2 VA Current 15 ma 15 ma Holding Voltage 80% of V N 80% of V N Release Voltage 0.3 x V 0.3 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in
3 Series 858, Relay Sockets with Industrial Relay voltage: 230 V AC 4 changeover contacts voltage: 230 V AC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact., for DIN 35 rail voltage 230 V AC 230 V AC Rated Power 1.2 VA 1.2 VA Current 8.3 ma 8.3 ma Holding Voltage 80% of V N 80% of V N Release Voltage 0.3 x V 0.3 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in
4 Series 858, Relay Sockets for Industrial Relay Relay socket for industrial relays 2 and 4 changeover contacts Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. Relay socket for industrial relays, for DIN 35 rail Nominal Input Voltage (V N ) Max. Switching Voltage Max. Continuous Current Max. Switching Power (resistive) Nominal Operating Mode Voltage Resistance Nominal Voltage Acc. to VDE 00 Part 1/4.97, Depending on relay; max. 250 V AC 250 V AC 4 x 8 A (4 changeover contacts); 2 x A (2 changeover contacts) 4000 VA AC Conituous duty 4 kv (depending on relay) 250 V/4 kv/3 Degree of Protection IP 20 Ambient Operating Temperature Storage Temperature Dimensions (mm) W x H x L Wire Connecion Stripped Lengths Cross Sections Standards/Specifications -25 o C o C (depending on relay) -40 o C o C x 38 x 97, Height from upper-edge of DIN 35 rail CAGE CLAMP S 9-10 mm/0.37 in 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG IEC60664/IEC60664A/DIN VDE00 Degree of pollution 2 Overvoltage category 2
5 Series 858, Accessories for Relay Socket Pluggable industrial relays 4 changeover contacts with integrated LED and recovery diode and manual operation Pluggable industrial relays 4 changeover contacts with integrated LED and manual operation * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. Nominal Input Nominal Input Description Voltage (V Item No. Pack. Unit Item No. Pack. Unit N ) Voltage (V N ) Pluggable Industrial Relay V DC V AC max,5 max 5,8 35 max V DC* V AC* voltage V DC 0 V AC Rated Power 0.9 W 1.2 W Current 36.9 ma 8.3 ma Holding Voltage 50% of V N 80% of V N Release Voltage 0.1 x V 0.3 x V Contact Material AgCe, AgCe + 5 μm Au* AgCe, AgCe + 5 μm Au* Continuous Current 5 A* 5 A* Max. Switching Voltage 250 V AC/ 30 V DC 250 V AC/30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Mounting Distance in a Row 6 mm 6 mm Weight approx. 37 g approx. 37 g
6 Series 858, Accessories Description Item No. Pack. Unit Holding Bracket for Industrial Relays Description Item No. Pack. Unit Push-In Type Jumper Bar Description Power Consumption at V N Item No. Pack. Unit Status Indication* 2.4 ma ma ma ma ma ma *Only required when using relays without integrated operating indicator. WAGO Corporation N0 W199 Freistadt Road Germantown, Wisconsin 530 Telephone: 800 / DIN Rail (6-75) Fax: 262 / 255- info.us@wago.com
46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T
46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection
More informationCO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi
46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils
More information5 mm contact pin pitch PCB or 95 series sockets
1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket
More information40 Series - Miniature PCB relays A. Features
1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More information2 pole 10 A PCB mount A1 A
Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)
More informationRUC industrial relays of small dimensions
RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A 55 Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationScheda prodotto Relè Series E
Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range
More informationContact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage
35 Royal Road Flemington, NJ 08822-6000 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage R ated load Min. switching current Max. inrush current
More informationPluggable interface relays RT, PT and MT range
Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and
More information2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current
0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More informationMiniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil
2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationVEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA
P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL
More information60 Series - General purpose relays 6-10 A. Features SERIES
60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationTime scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets
86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module
More informationFused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series
28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the
More informationGeneral purpose relays 6-10 A
60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control
More information90 Series - Socket overview for 60 series relays
90 Series - Socket overview for 0 series relays See page 90 90.0 99.0 90.0 0. Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC 90.0 0. Double terminal (EN 00) mount suppression
More informationMiniature Industrial relay 8-16 A
46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical
More informationSlim P.C.B. Relays (EMR or SSR) A
34 SЕRIES Slim P.C.B. Relays (EMR or SSR) 0.1-0.2-2 - 6 Bottling plant Packaging machines Labelling machines Road / tunnel lighting Burners, boilers and furnaces Timers and lighting controls Electronic
More informationIndustrial Relay KML(1C, 2C)
Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More information44 SERIES. PCB/Plug-in relays from 6 to 10 A
44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)
More information881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi
Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL
More informationGeneral purpose relays 7-10 A
55 SЕRIES General purpose relays 7-10 utomation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information1 Form A 5A small size power relay for interface
1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch
More informationxxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads
22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More information6mm and 14mm Slim Interface Relay
6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for
More informationGeneral_technical_data Series
Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationElectronic timers CT-S range Function diagrams
CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;
More informationElectronic timers CT-E range Selection and ordering details
Selection and ordering details Characteristics 12 single function and 2 multifunction (24-240VAC/DC) Single or dual supply voltage ranges 24VAC/DC, 110-130VAC, 220-240VAC Output contacts 1c/o contact (250V
More information6mm Interface Relays RV8 Series
6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.
More informationMiniature General Purpose Relay HY
www.industrialcontroldirect.com Tel: --00 Fax: -9-09 info@industrialcontroldirect.com Miniature General Purpose Relay HY General purpose, amp Plug in Power Relay, available in PCO, PCO and PCO Arc barriers
More informationData sheet TERMSERIES TRZ 120VUC 1CO
relay module, complete modules consisting of a relay and a base with AC/DC/UC coils, available in different versions: With screw and tension-clamp connection AgNi contact, optionally with hard gold-plated
More informationGeneral Purpose Relays Accessories. Accessories Industrial Power Relay RT
Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5 mm / 5 mm; n New retainer clip with ejection function n Easy replacement of relays on a densely packed DIN rail n No reduction of
More informationCrimpmate Range pitch 5.00
Contents pitch. pitch. pitch. Male and female connectors with solder connection. Male and female connectors with crimp connection. Crimp contacts..1 pitch. RSV 1. S Derating curve RSV1. S SN Rectangular
More information2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets
Miniature plug-in timers 7-10 A Plug-in timer.02-2 Pole 10 A.03-3 Pole 10 A.04-4 Pole 7 A Multifunctions Seven time scales, from 0.05 s to 100 h 94 series sockets for 35 mm rail (EN 60715) mount with push-in
More informationPressure switch hex 27
Pressure switch Changeover switch with silver or gold contacts Easily adjustable switching point. Factory adjustable hysteresis (except type 0140/014. High overpressure safety and long life even under
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationApplicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL
Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationL1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel
Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationV REG.-Nr. 6106, Z E SCHRACK. Accessories Industrial Power Relay RT. General Purpose Relays. pinnings 3.5mm / 5mm; relay height 15.
Accessories Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5mm / 5mm; relay height 15.7 mm n New retainer clip with ejection function n Easy replacement of relays on a densely packed
More informationG7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press
Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms
More informationMAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure
MAKING MODERN LIVING POSSIBLE Pressure switch BCP Technical brochure Contents Page Pressure switch, BCP Introduction...............................................................................3 Features...................................................................................3
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationFemale socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green
Female socket block, Screw connection, No. of poles: 12, Width: 45.72 mm, Colour: Green Business data Connector version Free connector Packaging unit 50 Quantity unit PC Packaging type Carton Type of banding
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationOrdering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays
Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationAXICOM Telecom-, Signal and RF Relays. W11 Relay V Nov. 07 Rev. C ECOC: JM10
108-98010 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that
More informationRUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED
Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationNEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.
Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high
More informationClearwater Tech - Phone: Fax: Web: -
Accessories Bus cables PROFIBUS-PA cables Straight version PROFIBUS-PA Ex i cables Straight version TM-I marker sleeve TM-I marker sleeve Designation Type Order No. Industrial zone PROFIBUS-PA cable One
More informationHV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556S form A contact (normally open) for PCBs
HV reed relays K-55H, K-55H K-55H, K-55H, K-555H, K-556S K-55H K-55H K-55H K-55H K-555H K-556S.CONTACT 0 Breakdown voltage min kv DC 7 0 7 8 9 0 Switching current max A 50 Load 5 kv DC, ma 0,5x0 6 Load
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationABL Series. Relay Terminal Block (Screwless Type) Features
ABL Series Relay Terminal Block (Screwless Type) Features Input (NPN, PNP common) and Output (Independent, Common) Selection with Jumper Bars Allows switching between NPN common and PNP common inputs by
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationSystem pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications
Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System
More informationHV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs
HV reed relays K-55H, K-55H K-55H, K-55H, K-555H PIT-RADWAR S.A. 50-5 Wrocław, ul. Krakowska 6, Poland tel. (+8) 7/-65-5, fax (+8) 7/-58-59.CONTACT K-55H K-55H K-55H K-55H K-555H Switching power max W,
More informationHan-Power Energy Bus Components
HARTING Electric Han-Power Energy Bus Components People Power Partnership Han Data Sheet 0080-7 Han-Power T Han-Power T Part-Number Drawing Dimensions in mm 09 12 008 4701 Cable gland please order separately
More informationDirectory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H
Directory chapter 03 () Types H, H 3, MH 24 + 7, MH 21 + 5 Page Technical characteristics type H.................................... 03.10 Type H connectors.................... 03.11 Type H 3 connectors..................
More informationDIGITAL TIME SWITCH SHT-1/2
9 DIGITAL TIME SWITCH SHT-1/2 Features: Universal supply voltage: AC/DC 12-240V SHT-1/2: two channel Daily, weekly program in one device Automatic conversion summer / winter time Switching: program (AUTO)/
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationRPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A
Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product
More information94 Series - Socket overview for 55 series relays
94 Series - Socket overview for 55 series relays 94.04 See page 7 Module Socket Relay Description Mounting 99.02 94.02 55.32 Screw terminal (Box clamp) socket Panel or 35 mm rail - Coil indication and
More informationModel Number Structure
Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can
More informationMiniature Intermediate Power Relay HY
Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationPCB Relay. Contact form Terminal Single-side stable Single-winding latching
PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationMagnetic Overcurrent Circuit Breaker
Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHP Flexy
Controllers AC Semiconductor Controller Type Soft starting and stopping of -phase induction squirrel cage motors Low inrush and reduced vibration during starting User-selected ramping profiles Integral
More informationMotor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.
Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring
More informationG7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets
Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes
More informationNEW. Datasheet. WMF 2.5 Terminal Series
Datasheet WMF 2.5 Terminal Series NEW The WMF 2.5 (multi-functional) terminal series is uniquely designed for DCS marshalling where increased functionality, improved spacing, higher wiring density and
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationSolenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11
2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation
More informationThe full feature relay includes the combination for rotary button or plain button or light or indicator flag.
FEATURES 3A / 5A/10A of general purpose relay DPDT and 3PDT and 4PDT contact arrangement Bifurcated contact: To increase contact reliability Flag indicator: Shows relay status or power condition L.E.D.
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationD4DL. Guard Lock Safety-door Switch. Model Number Structure
Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More information