Series 858, Relay Sockets with Industrial Relay

Size: px
Start display at page:

Download "Series 858, Relay Sockets with Industrial Relay"

Transcription

1 Series 858, Relay Sockets with Industrial Relay voltage: V DC 4 changeover contacts voltage: V DC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact , for DIN 35 rail voltage V DC V DC Rated Power 0.9 W 0.9 W Current 36.9 ma 36.9 ma Holding Voltage 50% of V N 50% of V N Release Voltage 0.1 x V 0.1 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in

2 Series 858, Relay Sockets with Industrial Relay voltage: 0 V AC 4 changeover contacts voltage: 0 V AC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact., for DIN 35 rail voltage 0 V AC 0 V AC Rated Power 1.2 VA 1.2 VA Current 15 ma 15 ma Holding Voltage 80% of V N 80% of V N Release Voltage 0.3 x V 0.3 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in

3 Series 858, Relay Sockets with Industrial Relay voltage: 230 V AC 4 changeover contacts voltage: 230 V AC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact., for DIN 35 rail voltage 230 V AC 230 V AC Rated Power 1.2 VA 1.2 VA Current 8.3 ma 8.3 ma Holding Voltage 80% of V N 80% of V N Release Voltage 0.3 x V 0.3 x V Contact Material AgCe AgCe + 5 μm Au Continuous Current 5 A 50 ma* Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Storage Temperature -40 o C o C -40 o C o C Dimensions (mm) W x H x L x 73 x 97, Height from upper-edge of DIN 35 rail x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S Cross Sections 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG Stripped Lengths 9-10 mm/0.37 in 9-10 mm/0.37 in

4 Series 858, Relay Sockets for Industrial Relay Relay socket for industrial relays 2 and 4 changeover contacts Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. Relay socket for industrial relays, for DIN 35 rail Nominal Input Voltage (V N ) Max. Switching Voltage Max. Continuous Current Max. Switching Power (resistive) Nominal Operating Mode Voltage Resistance Nominal Voltage Acc. to VDE 00 Part 1/4.97, Depending on relay; max. 250 V AC 250 V AC 4 x 8 A (4 changeover contacts); 2 x A (2 changeover contacts) 4000 VA AC Conituous duty 4 kv (depending on relay) 250 V/4 kv/3 Degree of Protection IP 20 Ambient Operating Temperature Storage Temperature Dimensions (mm) W x H x L Wire Connecion Stripped Lengths Cross Sections Standards/Specifications -25 o C o C (depending on relay) -40 o C o C x 38 x 97, Height from upper-edge of DIN 35 rail CAGE CLAMP S 9-10 mm/0.37 in 2 x 0. mm 2-2 x 1.5 mm 2 /1 x 2.5 mm 2 / - 16 AWG IEC60664/IEC60664A/DIN VDE00 Degree of pollution 2 Overvoltage category 2

5 Series 858, Accessories for Relay Socket Pluggable industrial relays 4 changeover contacts with integrated LED and recovery diode and manual operation Pluggable industrial relays 4 changeover contacts with integrated LED and manual operation * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. Nominal Input Nominal Input Description Voltage (V Item No. Pack. Unit Item No. Pack. Unit N ) Voltage (V N ) Pluggable Industrial Relay V DC V AC max,5 max 5,8 35 max V DC* V AC* voltage V DC 0 V AC Rated Power 0.9 W 1.2 W Current 36.9 ma 8.3 ma Holding Voltage 50% of V N 80% of V N Release Voltage 0.1 x V 0.3 x V Contact Material AgCe, AgCe + 5 μm Au* AgCe, AgCe + 5 μm Au* Continuous Current 5 A* 5 A* Max. Switching Voltage 250 V AC/ 30 V DC 250 V AC/30 V DC * Switching Power (Max.) AC1/AC15 50 VA/300 VA 50 VA/300 VA 1-Phase Motor Load AC3 0. kw 0. kw Min. Switching Load V/100 ma V/100 ma Nominal Voltage Acc. to VDE 00 Part 1/4.97, Dielectric Strength Contact- (1.2/50 μs) 4 kv 4 kv Dielectric Strength Contact- (AC, 1 min) 1.5 kv 1.5 kv Mounting Distance in a Row 6 mm 6 mm Weight approx. 37 g approx. 37 g

6 Series 858, Accessories Description Item No. Pack. Unit Holding Bracket for Industrial Relays Description Item No. Pack. Unit Push-In Type Jumper Bar Description Power Consumption at V N Item No. Pack. Unit Status Indication* 2.4 ma ma ma ma ma ma *Only required when using relays without integrated operating indicator. WAGO Corporation N0 W199 Freistadt Road Germantown, Wisconsin 530 Telephone: 800 / DIN Rail (6-75) Fax: 262 / 255- info.us@wago.com

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T 46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection

More information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi 46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils

More information

5 mm contact pin pitch PCB or 95 series sockets

5 mm contact pin pitch PCB or 95 series sockets 1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket

More information

40 Series - Miniature PCB relays A. Features

40 Series - Miniature PCB relays A. Features 1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

2 pole 10 A PCB mount A1 A

2 pole 10 A PCB mount A1 A Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A 55 Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Scheda prodotto Relè Series E

Scheda prodotto Relè Series E Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range

More information

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage 35 Royal Road Flemington, NJ 08822-6000 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage R ated load Min. switching current Max. inrush current

More information

Pluggable interface relays RT, PT and MT range

Pluggable interface relays RT, PT and MT range Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and

More information

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current 0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil 2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL

More information

60 Series - General purpose relays 6-10 A. Features SERIES

60 Series - General purpose relays 6-10 A. Features SERIES 60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Scheda prodotto Relè Series B

Scheda prodotto Relè Series B Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the

More information

General purpose relays 6-10 A

General purpose relays 6-10 A 60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control

More information

90 Series - Socket overview for 60 series relays

90 Series - Socket overview for 60 series relays 90 Series - Socket overview for 0 series relays See page 90 90.0 99.0 90.0 0. Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC 90.0 0. Double terminal (EN 00) mount suppression

More information

Miniature Industrial relay 8-16 A

Miniature Industrial relay 8-16 A 46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical

More information

Slim P.C.B. Relays (EMR or SSR) A

Slim P.C.B. Relays (EMR or SSR) A 34 SЕRIES Slim P.C.B. Relays (EMR or SSR) 0.1-0.2-2 - 6 Bottling plant Packaging machines Labelling machines Road / tunnel lighting Burners, boilers and furnaces Timers and lighting controls Electronic

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

44 SERIES. PCB/Plug-in relays from 6 to 10 A

44 SERIES. PCB/Plug-in relays from 6 to 10 A 44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)

More information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL

More information

General purpose relays 7-10 A

General purpose relays 7-10 A 55 SЕRIES General purpose relays 7-10 utomation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

6mm and 14mm Slim Interface Relay

6mm and 14mm Slim Interface Relay 6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Electronic timers CT-S range Function diagrams

Electronic timers CT-S range Function diagrams CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;

More information

Electronic timers CT-E range Selection and ordering details

Electronic timers CT-E range Selection and ordering details Selection and ordering details Characteristics 12 single function and 2 multifunction (24-240VAC/DC) Single or dual supply voltage ranges 24VAC/DC, 110-130VAC, 220-240VAC Output contacts 1c/o contact (250V

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Miniature General Purpose Relay HY

Miniature General Purpose Relay HY www.industrialcontroldirect.com Tel: --00 Fax: -9-09 info@industrialcontroldirect.com Miniature General Purpose Relay HY General purpose, amp Plug in Power Relay, available in PCO, PCO and PCO Arc barriers

More information

Data sheet TERMSERIES TRZ 120VUC 1CO

Data sheet TERMSERIES TRZ 120VUC 1CO relay module, complete modules consisting of a relay and a base with AC/DC/UC coils, available in different versions: With screw and tension-clamp connection AgNi contact, optionally with hard gold-plated

More information

General Purpose Relays Accessories. Accessories Industrial Power Relay RT

General Purpose Relays Accessories. Accessories Industrial Power Relay RT Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5 mm / 5 mm; n New retainer clip with ejection function n Easy replacement of relays on a densely packed DIN rail n No reduction of

More information

Crimpmate Range pitch 5.00

Crimpmate Range pitch 5.00 Contents pitch. pitch. pitch. Male and female connectors with solder connection. Male and female connectors with crimp connection. Crimp contacts..1 pitch. RSV 1. S Derating curve RSV1. S SN Rectangular

More information

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets Miniature plug-in timers 7-10 A Plug-in timer.02-2 Pole 10 A.03-3 Pole 10 A.04-4 Pole 7 A Multifunctions Seven time scales, from 0.05 s to 100 h 94 series sockets for 35 mm rail (EN 60715) mount with push-in

More information

Pressure switch hex 27

Pressure switch hex 27 Pressure switch Changeover switch with silver or gold contacts Easily adjustable switching point. Factory adjustable hysteresis (except type 0140/014. High overpressure safety and long life even under

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

V REG.-Nr. 6106, Z E SCHRACK. Accessories Industrial Power Relay RT. General Purpose Relays. pinnings 3.5mm / 5mm; relay height 15.

V REG.-Nr. 6106, Z E SCHRACK. Accessories Industrial Power Relay RT. General Purpose Relays. pinnings 3.5mm / 5mm; relay height 15. Accessories Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5mm / 5mm; relay height 15.7 mm n New retainer clip with ejection function n Easy replacement of relays on a densely packed

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

MAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure

MAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure MAKING MODERN LIVING POSSIBLE Pressure switch BCP Technical brochure Contents Page Pressure switch, BCP Introduction...............................................................................3 Features...................................................................................3

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green Female socket block, Screw connection, No. of poles: 12, Width: 45.72 mm, Colour: Green Business data Connector version Free connector Packaging unit 50 Quantity unit PC Packaging type Carton Type of banding

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

AXICOM Telecom-, Signal and RF Relays. W11 Relay V Nov. 07 Rev. C ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. W11 Relay V Nov. 07 Rev. C ECOC: JM10 108-98010 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

Clearwater Tech - Phone: Fax: Web: -

Clearwater Tech - Phone: Fax: Web:  - Accessories Bus cables PROFIBUS-PA cables Straight version PROFIBUS-PA Ex i cables Straight version TM-I marker sleeve TM-I marker sleeve Designation Type Order No. Industrial zone PROFIBUS-PA cable One

More information

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556S form A contact (normally open) for PCBs

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556S form A contact (normally open) for PCBs HV reed relays K-55H, K-55H K-55H, K-55H, K-555H, K-556S K-55H K-55H K-55H K-55H K-555H K-556S.CONTACT 0 Breakdown voltage min kv DC 7 0 7 8 9 0 Switching current max A 50 Load 5 kv DC, ma 0,5x0 6 Load

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

ABL Series. Relay Terminal Block (Screwless Type) Features

ABL Series. Relay Terminal Block (Screwless Type) Features ABL Series Relay Terminal Block (Screwless Type) Features Input (NPN, PNP common) and Output (Independent, Common) Selection with Jumper Bars Allows switching between NPN common and PNP common inputs by

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs HV reed relays K-55H, K-55H K-55H, K-55H, K-555H PIT-RADWAR S.A. 50-5 Wrocław, ul. Krakowska 6, Poland tel. (+8) 7/-65-5, fax (+8) 7/-58-59.CONTACT K-55H K-55H K-55H K-55H K-555H Switching power max W,

More information

Han-Power Energy Bus Components

Han-Power Energy Bus Components HARTING Electric Han-Power Energy Bus Components People Power Partnership Han Data Sheet 0080-7 Han-Power T Han-Power T Part-Number Drawing Dimensions in mm 09 12 008 4701 Cable gland please order separately

More information

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H Directory chapter 03 () Types H, H 3, MH 24 + 7, MH 21 + 5 Page Technical characteristics type H.................................... 03.10 Type H connectors.................... 03.11 Type H 3 connectors..................

More information

DIGITAL TIME SWITCH SHT-1/2

DIGITAL TIME SWITCH SHT-1/2 9 DIGITAL TIME SWITCH SHT-1/2 Features: Universal supply voltage: AC/DC 12-240V SHT-1/2: two channel Daily, weekly program in one device Automatic conversion summer / winter time Switching: program (AUTO)/

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product

More information

94 Series - Socket overview for 55 series relays

94 Series - Socket overview for 55 series relays 94 Series - Socket overview for 55 series relays 94.04 See page 7 Module Socket Relay Description Mounting 99.02 94.02 55.32 Screw terminal (Box clamp) socket Panel or 35 mm rail - Coil indication and

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Miniature Intermediate Power Relay HY

Miniature Intermediate Power Relay HY Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy Controllers AC Semiconductor Controller Type Soft starting and stopping of -phase induction squirrel cage motors Low inrush and reduced vibration during starting User-selected ramping profiles Integral

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes

More information

NEW. Datasheet. WMF 2.5 Terminal Series

NEW. Datasheet. WMF 2.5 Terminal Series Datasheet WMF 2.5 Terminal Series NEW The WMF 2.5 (multi-functional) terminal series is uniquely designed for DCS marshalling where increased functionality, improved spacing, higher wiring density and

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

The full feature relay includes the combination for rotary button or plain button or light or indicator flag. FEATURES 3A / 5A/10A of general purpose relay DPDT and 3PDT and 4PDT contact arrangement Bifurcated contact: To increase contact reliability Flag indicator: Shows relay status or power condition L.E.D.

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information