90 Series - Socket overview for 60 series relays
|
|
- Chloe Fletcher
- 5 years ago
- Views:
Transcription
1 90 Series - Socket overview for 0 series relays See page Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC Double terminal (EN 00) mount suppression modules - Jumper link - Timer modules - Metal retaining clip Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC (EN 00) mount suppression modules - Metal retaining clip See page Screw terminal (Box clamp) socket Panel or mm rail - Metal retaining clip (EN 00) mount 0 See page Screw terminal (Box clamp) socket Panel or mm rail - Metal retaining clip (EN 00) mount See page Screw terminal (Plate clamp) socket Panel or mm rail - Metal retaining clip (EN 00) mount See page Flange mount solder socket M screw fixing See page PCB socket PCB See page 9 9
2 90 Series - Sockets and accessories for 0 series relays A 90.0 COM COM.. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type Metal retaining clip way jumper link Identification tag Modules (see table below) 99.0 Timer modules (see table below).00,.0,.0 kv AC Protection category IP 0 Ambient temperature C Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90.0 and 90.0 sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x / x A 0 COM COM START 90.0 COM way jumper link for 90.0 and 90.0 sockets *Modules in Black housing are available on request. 90 series timer modules (see technical data pages //) Multi-voltage: ( 0)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.0 s 00 h) Mono-function: ( )V AC/DC; function AI; (. s 0 min) Mono-function: ( )V AC/DC; function DI; (. s 0 min) coil indication and EMC suppression modules (see technical data pages /) Blue* Diode (+, standard polarity) (...0)V DC Diode (+A, non-standard polarity) (...0)V DC LED (...)V DC/AC LED (...0)V DC/AC LED (0...0)V DC/AC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (...0)V DC LED + Diode (+, standard polarity) (0...0)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (...0)V DC LED + Diode (+A, non-standard polarity) (0...0)V DC LED + Varistor (...)V DC/AC LED + Varistor (...0)V DC/AC LED + Varistor (0...0)V DC/AC RC circuit (...)V DC/AC RC circuit (...0)V DC/AC RC circuit (0...0)V DC/AC Residual current by-pass ( kω/w) (0...0)V AC
3 90 Series - Sockets and accessories for 0 series relays 90. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type Metal retaining clip (supplied with socket - packaging code SMA) 090. Modules (see table below) 99.0 kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90.0 and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x0 / x A COM COM 0 A 0 COM COM COM *Modules in Black housing are available on request. Green LED is standard. Red LED available on request coil indication and EMC suppression modules for 90.0 and 90. sockets See technical data pages / Blue* Diode (+, standard polarity) (...0)V DC Diode (+A, non-standard polarity) (...0)V DC LED (...)V DC/AC LED (...0)V DC/AC LED (0...0)V DC/AC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (...0)V DC LED + Diode (+, standard polarity) (0...0)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (...0)V DC LED + Diode (+A, non-standard polarity) (0...0)V DC LED + Varistor (...)V DC/AC LED + Varistor (...0)V DC/AC LED + Varistor (0...0)V DC/AC RC circuit (...)V DC/AC RC circuit (...0)V DC/AC RC circuit (0...0)V DC/AC Residual current by-pass ( kω/w) (0...0)V AC
4 90 Series - Sockets and accessories for 0 series relays 90.. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type Metal retaining clip 090. kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Max. wire size for 90.. and 90.. sockets solid wire stranded wire mm x / x x / x AWG x0 / x x0 / x com. Ø.. Ø. 0 9 A COM COM 9. A 0 COM COM Screw (Box clamp) terminal socket 90. (blue) 90. (blue) panel or mm rail (EN 00) mount For relay type Metal retaining clip (supplied with socket - packaging code SMA) 090. kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm Max wire size for 90. and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x0 / x 0 0 COM b a COM COM.9 b 9 0 a COM COM
5 90 Series - Sockets and accessories for 0 series relays 90. Screw terminal (Plate clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type Metal retaining clip (supplied with socket - packaging code SMA) 090. kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90. and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x / x x / x 0 com fl. = = 0 A COM COM A 0 COM COM Flange mount solder socket mount with M screw 90. (black) 90. (black) For relay type kv AC 90. Ambient temperature C Ø PCB socket Blue Blue 90.. (Ø.mm) 90.. (Ø 9mm) For relay type kv AC Ambient temperature C 0 +0 '"... '" A
6 90 Series - Sockets and accessories for 0 series relays Packaging code How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: 9 0. S M A A Standard packaging SM Metal retaining clip 9 0. Without retaining clip 0 9
94 Series - Socket overview for 55 series relays
94 Series - Socket overview for 55 series relays 94.04 See page 7 Module Socket Relay Description Mounting 99.02 94.02 55.32 Screw terminal (Box clamp) socket Panel or 35 mm rail - Coil indication and
More information2 pole 10 A PCB mount A1 A
Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A 55 Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More information5 mm contact pin pitch PCB or 95 series sockets
1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket
More information46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T
46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection
More information40 Series - Miniature PCB relays A. Features
1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole
More information2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current
0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket
More information60 Series - General purpose relays 6-10 A. Features SERIES
60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils
More informationTime scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets
86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module
More informationCO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi
46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More informationGeneral purpose relays 6-10 A
60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control
More informationGeneral purpose relays 7-10 A
55 SЕRIES General purpose relays 7-10 utomation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches
More information44 SERIES. PCB/Plug-in relays from 6 to 10 A
44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)
More informationMiniature Industrial relay 8-16 A
46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical
More information2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets
Miniature plug-in timers 7-10 A Plug-in timer.02-2 Pole 10 A.03-3 Pole 10 A.04-4 Pole 7 A Multifunctions Seven time scales, from 0.05 s to 100 h 94 series sockets for 35 mm rail (EN 60715) mount with push-in
More informationV REG.-Nr. 6106, Z E SCHRACK. Accessories Industrial Power Relay RT. General Purpose Relays. pinnings 3.5mm / 5mm; relay height 15.
Accessories Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5mm / 5mm; relay height 15.7 mm n New retainer clip with ejection function n Easy replacement of relays on a densely packed
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationGeneral Purpose Relays Accessories. Accessories Industrial Power Relay RT
Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5 mm / 5 mm; n New retainer clip with ejection function n Easy replacement of relays on a densely packed DIN rail n No reduction of
More informationPluggable interface relays RT, PT and MT range
Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and
More informationGeneral Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
More informationAccessories Miniature Relay PT (Continued)
Accessories Miniature Relay PT Easy replacement of relays on a densely packed DIN rail No reduction of protection class or creepage/clearance with plastic retainer Plug-in indicator- and protection modules
More informationRUC industrial relays of small dimensions
RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current
More informationSlim P.C.B. Relays (EMR or SSR) A
34 SЕRIES Slim P.C.B. Relays (EMR or SSR) 0.1-0.2-2 - 6 Bottling plant Packaging machines Labelling machines Road / tunnel lighting Burners, boilers and furnaces Timers and lighting controls Electronic
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationMiniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil
2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationFINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS
Finder relays, modular timers and accessories in stock at FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS Finder Relay has hundreds of possible combinations of relays and modular timers. Those
More informationContact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage
35 Royal Road Flemington, NJ 08822-6000 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage R ated load Min. switching current Max. inrush current
More informationAccessories Miniature Relay PT
Accessories Miniature Relay PT Easy replacement of relays on a densely packed DIN rail Socket with logical arrangement of control/load terminals High quality rising clamp terminals Captive combination
More informationSeries 858, Relay Sockets with Industrial Relay
Series 858, Relay Sockets with Industrial Relay voltage: V DC 4 changeover contacts voltage: V DC 4 changeover contacts (gold contacts) * In order to prevent the gold layer from being damaged, these values
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationABL Series. Relay Terminal Block (Screwless Type) Features
ABL Series Relay Terminal Block (Screwless Type) Features Input (NPN, PNP common) and Output (Independent, Common) Selection with Jumper Bars Allows switching between NPN common and PNP common inputs by
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationIndustrial Relay KML(1C, 2C)
Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationMiniature General Purpose Relay HY
www.industrialcontroldirect.com Tel: --00 Fax: -9-09 info@industrialcontroldirect.com Miniature General Purpose Relay HY General purpose, amp Plug in Power Relay, available in PCO, PCO and PCO Arc barriers
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationNEW. Datasheet. WMF 2.5 Terminal Series
Datasheet WMF 2.5 Terminal Series NEW The WMF 2.5 (multi-functional) terminal series is uniquely designed for DCS marshalling where increased functionality, improved spacing, higher wiring density and
More informationCharacteristics TeSys contactors 0 TeSys k contactors and reversing contactors
90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp
More informationxxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads
22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More information2/2 or 3/2 way direct acting rocker solenoid valve
2/2 or 3/2 way direct acting rocker solenoid valve With isolating diaphragm Ultra low dead volume Type 6126 can be combined with... High back-pressure tightness Normally closed, normally open or universal
More informationPowermate Range pitch 7.00 Powermate Range pitch 7.00
Contents lug and socket connectors with leaf spring connection.2 lug and socket connectors with TO connection.6.1 lug and socket connectors with leaf spring connection STVS S Derating curve STVS SB Socket
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationCVR-625. Compact Vibrating Rod Instruction Manual
CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS
More informationGeneral Purpose Relay
General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge
More informationCrimpmate Range pitch 5.00
Contents pitch. pitch. pitch. Male and female connectors with solder connection. Male and female connectors with crimp connection. Crimp contacts..1 pitch. RSV 1. S Derating curve RSV1. S SN Rectangular
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationCSF - CSM CONNECTORS. Functional characteristics. RoHS 2011/65/EU. Brief description. Dimensional class: low. Standard colour: green
- CSM Functional characteristics Dimensional class: low 0 RoHS 2011/65/EU Standard colour: green Dimensions: 14 x 11.5 mm (.551 x.453 in) 10 20 30 mm ½ 1 in Max approved wire size: solid: 2.5 mm 2 (IMQ);
More informationPCB plug-in connectors
Contents CB plug-in connectors.16 mm pitch.16 mm pitch Male connectors with solder connection.2 Socket connectors with clamping yoke connection.8.1 Male connectors with solder connection SU.16H/9 Derating
More informationRoHS 2002/95/EC GREEN ELECTRONICS CVF. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007
RoHS 2002/95/EC e3 GREEN ELECTRONICS Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET Standard PRODUCTS CONNECTORS
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationRoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CIF. Connectors
RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 Connectors Functional characteristics Dimensional class: medium RoHS 2011/65/EU Standard colour: green Dimensions: 18.4 x 15.5
More informationR600 & R500. Interface relays R600, R500. Phone: Fax: Web: -
R00, R500 R00 CR & R500 Range Range R00 & R500 R00 CR & R500 Range Range, R00, R500 Benefits and advantages R00 series Standard range in screw clamp or spring clamp versions Spacing : mm Wire size : 2.5
More informationMK 2/ mm 2 IEC UL CSA. IEC UL CSA Rated voltage AWG AWG AWG AWG Rated surge voltage / pollution severity
or direct mounting Screw connection MK 2/12 2.5 mm 2 MK 3/2... 12 2.5 mm 2 Width x height / ø fixing hole mm 15.0 x 15.0 / 3.20 15.0 x 16.1 / 3.45 (length and mounting size: see order data) Max. clamping
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationCIF CONNECTORS. Functional Characteristics. Brief Description. RoHS 2002/95/EC. Dimensional Class: Medium. Standard Colour: Green
SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET STD PRODUCTS CONNECTORS Functional Characteristics Dimensional Class: Medium Standard Colour: Green Dimensions: 18.4 x 15.5 mm (.724 x.610 in) Max Approved Wire
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationSafety technique. Emergency Stop Module BH 5928, BI 5928
Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category
More informationUP Series Miniature Pilot Lights
Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.
More informationHMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch
Edition 10/2016 HMI Components Series Characteristics The compact Series is especially suited for: Flush design The large rectangular design (24x36mm) features a large illuminated area. Functions The Series
More informationAmphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003
Amphenol eries SJT Series SJT VG 96912, Series 1 PAN 6433-2 JN 1003 Ordering information Ordering example: SJT G 06 RT 14-35 P A 014 Series (p. 9, 15, 18) SJT Scoop proof (100% scoop-proof) Junior (Miniature
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationMOTHMAN FUZZ ASSEMBLY INSTRUCTIONS RECOMMENDED TOOL AND SUPPLY LIST MOTHMAN FUZZ KIT PARTS LIST
MOTHMAN FUZZ ASSEMBLY INSTRUCTIONS Thank you for purchasing the J201 Clean Boost Pedal Kit from Mammoth Electronics! This is a intermediate level kit that and we have made every effort to make the assembly
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationType Terminal Coil Contact form Model
General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode
More informationMiniature Intermediate Power Relay HY
Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations
More informationHan K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/
Han K 3/0, K 3/2 / Han HC Contents Page Technical characteristics Han K 3/0, Han K 3/2... 14.02 Inserts Han K 3/0, Han K 3/2... 14.03 Hoods/Housings Han 24 HPR for Han K 3/0, Han K 3/2... 14.04 Technical
More informationRoHS 2002/95/EC GREEN ELECTRONICS CSF. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007
RoHS 2002/95/EC e3 GREEN ELECTRONICS CSF Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET STD PRODUCTS CONNECTORS
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationRated voltage (V) Current (A) Stranded wire. Solid wire A.D.O. (AWG)
Characteristics (1) Dimensions are on DIN 3 rail : PR4 (Height 15 mm) Use of a PR3 rail : remove 7,5 mm on dimension B Use of a DIN 1 rail : remove 2,5 mm on dimension B remove 5 mm on dimension C Miniblocks
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationDatasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX
High-performance female connector with the tried-and-tested, guaranteed zero-maintenance, Weidmüller steel clamping yoke. Side-by-side mounting without losing any poles or with patented multifunction flange
More informationSafety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12
Safety Door Handle System TGY with SIDENT Safety Switch Ref. no. 43.20-01 07, -11, -12 1. Purpose Automated systems with dangerous machine functions require guards to ensure that the operating personnel
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationRelays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers
RV8 Series 6mm Interface Relays Key features: Class I, Division 2 and Class I, Zone 2 Hazardous Location options (electromechanical relays only) Solid State relay versions available Only 70mm in height
More informationFused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series
28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the
More informationSolenoid coil Types BB, BE, BF, BG, and BN
Data sheet Solenoid coil Types BB, BE, BF, BG, and BN The coils are specially designed to operate in the aggressive environment of high humidity and temperature fluctuations that you find in most refrigeration
More informationDECIDUOUS FILTER ASSEMBLY INSTRUCTIONS RECOMMENDED TOOL AND SUPPLY LIST DECIDUOUS FILTER KIT PARTS LIST
DECIDUOUS FILTER ASSEMBLY INSTRUCTIONS Thank you for purchasing the Deciduous Filter Effect Pedal Kit from Mammoth Electronics! This is an intermediate level kit and we have made every effort to make the
More information2/2-way Solenoid Valve with servo diaphragm
2/2-way Solenoid Valve with servo diaphragm Type 5282 can be combined with... Pivoted armature pilot drive with manual override Magnetic drive completely isolated from fluid by diaphragm Circuit function
More informationSeries PD directly operated solenoid valves
> Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current
More informationRoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CTF. Connectors
RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 Connectors Functional characteristics Dimensional class: low RoHS 2011/65/EU Standard colour: green Dimensions: 11.1 x 15.5 mm
More informationVEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA
P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL
More information3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base
3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override
More informationEmergency lighting units EM powerled
EM power EM power BASIC 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationMagnetic Overcurrent Circuit Breaker
Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically
More information