Size 3 and 4 Starter. Reversing Catalog Number as specified in table below. Catalog Number. Price U.S. $ W201K1CF W201K1CN W201K2CF W201K2CN

Size: px
Start display at page:

Download "Size 3 and 4 Starter. Reversing Catalog Number as specified in table below. Catalog Number. Price U.S. $ W201K1CF W201K1CN W201K2CF W201K2CN"

Transcription

1 - Contactors Non-reversing and eversing ebruary 7 Contents Description Product amily Overview Page Product Description Benefits Contactors Non-reversing and eversing Product Description eatures Product Selection Technical Data Accessories and ield Modification Kits enewal Parts Control Modules Dimensions Wiring Diagrams Size 3 and 4 Starter Product Description W0 Nonreversing Contactors W Horizontal eversing Contactors (shown above) long axis horizontal W Vertical eversing Contactors (not illustrated) long axis vertical eatures Small physical size Brownout protection Communications capability Long electrical life Higher contact force Product Selection When Ordering Specify Non-reversing as specified in table below. eversing as specified in table below. Table -30. Contactors 3-Pole Non-reversing and eversing NEMA Sizes 6 NEMA Size Voltage Max. hp Coil Voltage/Hz Non-reversing eversing (Horizontal) eversing (Vertical) Continuous (Enclosed) / 7-/ / / / / /60 5 0/60 W0KC W0KCN W0KC W0KCN W0K3C W0K3CN W0K4C W0K4CN W0K5C W0K5CN W0K6C W0K6CN WKC WKCN WKC WKCN WK3C WK3CN WK4C WK4CN WK5C WK5CN WK6C WK6CN WKC WKCN WKC WKCN WK3C WK3CN WK4C WK4CN WK5C WK5CN WK6C WK6CN Discount Symbol CD CA080E

2 ebruary 7 Starters Non-reversing and eversing -3 Contents Description Product amily Overview Page Product Description Benefits Starters Non-reversing and eversing Product Description eatures Technical Data Options Product Selection Technical Data Accessories and ield Modification Kits enewal Parts Control Modules Dimensions Wiring Diagrams eatures Starter Small physical size Brownout protection Communications capability Minimized bounce times Higher contact force Common auxiliary contacts Protection Heaters not required selectable settings Overload protection accuracy % Phase loss and phase unbalance protection Ground current protection OL Protection Settings Selectable automatic/manual reset Selectable trip class 0, 0, 30 or no protection (disables overload) Selectable trip current Technical Data Table LA anges NEMA Size or motor full load current (LA) range of.47a 3.8A with a.5 to. service factor and for motor hp range of /4 hp to hp at V. Options.5 to Table eatures Description.0 Service actor Omit Class II Ground-Current Protection Omit Phase-Loss Protection Omit both Class II Ground-Current Protection and Phase-Loss Protection Suffix Y7 Y4 Y4Y7 Size 5 and 6 Starter Product Description W Nonreversing Starters (shown above) W0 Horizontal eversing Starters long axis horizontal. W0 Vertical eversing Starters (not illustrated) long axis vertical. CA080E

3 -4 Starters Non-reversing and eversing ebruary 7 Product Selection When Ordering Specify Non-reversing as specified in table below. eversing as specified in table below. Table Starters 3-Pole Non-reversing and eversing Wired for Separate Control Heaters Not equired NEMA Sizes 6 NEMA Size Voltage Max. hp 7-/ 7-/ Continuous (Enclosed) Coil Voltage/Hz 7 0/60 7 0/ / / / /60 5 0/60 Non-reversing eversing (Horizontal) eversing (Vertical) WMLCC WMLCNC WMCC WMCNC WMCC WMCNC WM3CC WM3CNC WM4CC WM4CNC WM5CC WM5CNC WM6CC WM6CNC W0MLCC W0MLCNC W0MCC W0MCNC W0MCC W0MCNC W0M3CC W0M3CNC W0M4CC W0M4CNC W0M5CC W0M5CNC W0M6CC W0M6CNC W0MLCC W0MLCNC W0MCC W0MCNC W0MCC W0MCNC W0M3CC W0M3CNC W0M4CC W0M4CNC W0M5CC W0M5CNC W0M6CC W0M6CNC or motor full load current (LA) range of.47a 3.8A with a.5 to. service factor and for motor hp range of /4 hp to hp at V. Discount Symbol CD CA080E

4 ebruary 7 Starters Non-reversing, Two-Speed - Contents Description Product amily Overview Page Product Description Benefits Starters Non-reversing Two-Speed Product Selection Technical Data Accessories and ield Modification Kits enewal Parts Control Modules Dimensions Wiring Diagrams Product Selection When Ordering Specify as shown in table below. Table Two-Speed Starters Wired for Separate Control Heaters Not equired NEMA Sizes 6 NEMA Size Voltage Max. Horsepower Constant or Variable Torque Constant hp or Separate () Winding Type s Wye Wye / 7-/ / 7-/ 7-/ Continuous (Enclosed) Coil Voltage/ Hz 7 0/60 7 0/ / / / /60 5 0/60 Open Type (Horizontal) W960MLCCM3 W960MLCNCM3 W960MCCM3 W960MCNCM3 W960MCCM3 W960MCNCM3 W960M3CCM3 W960M3CNCM3 W960M4CCM3 W960M4CNCM3 W960M5CCM3 W960M5CNCM3 W960M6CCM3 W960M6CNCM3 or motor full load current (LA) range of.47a 3.8A with a.5 to. service factor and for motor hp range of /4 hp to hp at V. Discount Symbol CD CA080E

5 -6 Starters Non-reversing, Two-Speed ebruary 7 Table Two-Speed Starters Wired for Separate Control Heaters Not equired NEMA Sizes 6 (Continued) NEMA Size Voltage Max. Horsepower Constant or Variable Torque Constant hp or Single Winding Type s Constant Horsepower / 7-/ 7-/ Continuous (Enclosed) Coil Voltage/ Hz 7 0/60 7 0/ / / / /60 5 0/60 or Single Winding Type s (Constant or Variable Torque) / 7-/ /60 7 0/ / / / /60 5 0/60 Open Type (Horizontal) W970MLCCM3 W970MLCNCM3 W970MCCM3 W970MCNCM3 W970MCCM3 W970MCNCM3 W970M3CCM3 W970M3CNCM3 W970M4CCM3 W970M4CNCM3 W970M5CCM3 W970M5CNCM3 W970M6CCM3 W970M6CNCM3 W980MLCCM3 W980MLCNCM3 W980MCCM3 W980MCNCM3 W980MCCM3 W980MCNCM3 W980M3CCM3 W980M3CNCM3 W980M4CCM3 W980M4CNCM3 W980M5CCM3 W980M5CNCM3 W980M6CCM3 W980M6CNCM3 or motor full load current (LA) range of.47a 3.8A with a.5 to. service factor and for motor hp range of /4 hp to hp at V. Discount Symbol CD CA080E

6 ebruary 7 Technical Data and Specifications -7 Table Electrical Characteristics, Sizes 6 Description Size Size Size 3 Size 4 Size 5 Size 6 Maximum Voltage ating Ampere ating Open Enclosed 30A 7A A 45A 00A 90A A 35A 300A 70A 600A 5A Maximum Horsepower Squirrel Cage V, 60 Hz V, 60 Hz 380V, Hz V, 60 Hz esistive Heating, kw Three-Phase, 3-Pole 0V V Capacitor Switching kva Three-Phase V Transformer Switching, kva Three-Phase, 3-Pole 08V V 7-/ hp 7-/ hp 0 hp 0 hp 5 kw 0 kw 0 kw kw 0 hp 5 hp hp hp esistive loads having inrush currents not exceeding.5 times continuous rating. Transformers having inrush currents not more than 0 times peak of continuous current ratings. 3.6 kva 4.3 kva 8.5 kva kva 8.5 kw 7 kw 34 kw 43 kw kva kva 3 kva 6.3 kva 7. kva 4 kva 8 kva hp 30 hp hp hp 7 kw 34 kw 68 kw 86 kw 7 kva 53 kva 67 kva kva 4 kva 8 kva 35 kva hp hp hp 00 hp 6 kw 68 kw 05 kw 30 kw kva 80 kva 00 kva 0 kva 3 kva 47 kva 59 kva hp 00 hp hp hp 5 kw 05 kw 0 kw 60 kw 80 kva 60 kva kva 4 kva 47 kva 94 kva 7 kva hp hp 300 hp 0 hp 05 kw 0 kw 45 kw 55 kw 60 kva 30 kva 0 kva 8 kva 94 kva 88 kva 34 kva Table V, Hz Starters Maximum Horsepower atings NEMA Size Maximum hp Ground Current Sensing Protection Eaton s Cutler-Hammer starters with ground current sensing protection feature provide equipment protection against ground currents between a factory-set low level and a lockout current. It is designed to open the circuit when it senses the low-level and arcing ground currents often occurring in motor branch circuits. This feature is standard with Cutler-Hammer starters. The ground current sensing protection feature can either be omitted from devices supplied by the factory, or omitted in the field by modifying the device with an Programming Module (WAPM). Note: These devices are NOT Ground ault Interrupters (GIs) designed to protect people. Additionally, branch circuit short-circuit protective devices are to be used to clear faults that exceed the interrupting rating of the starter. Table Ground Current Sensing Size Current Lockout Current Time IL sec sec sec sec sec sec sec. The table above gives trip amperes and lockout amperes for each size of the starter. Lockout current is the sum of the phase current and ground current. Phase Unbalance If the unbalance of any two phases is greater than 30% of the DIP switch selected trip rating of the starter, a phase unbalance is declared and a trip occurs. No time delay is required for reset. This feature is standard in the Cutler-Hammer starter. To customize your protection, phase unbalance can be omitted by disabling the protection using an Programming Module (WAPM). Phase Loss The starter will trip on phase loss, after two seconds, if the current in any one phase is lower than the currents listed in the table below. No time delay is required for reset. Phase loss protection is standard on the Cutler- Hammer starter. The phase loss protection feature can either be omitted from devices supplied by the factory, or omitted in the field by modifying the device with an Programming Module (WAPM). Table -30. Phase Time Size Size Size 3 Size 4 Size 5 Size 6 Phase Unbalance Level Phase Unbalance Delay Phase Loss after sec. if Phase Current is below: 30% Unbalance 6 sec. 9 sec. sec..5a.5a.5a.5a.5a A A Size Lower Current ange for motor hp range of /4 hp to hp at V. CA080E

7 -8 Technical Data and Specifications ebruary 7 Table -3. Operating Coil Characteristics at ated Coil Volts, Sizes 6 Description Size Size Size 3 Size 4 Size 5 Size 6 AC Coil Burden Inrush VA Closed VA Closed Watts Pick-Up Volts Drop-Out Volts ecommended VA rating for machine tool control power transformers 0 VA VA 5W 78V 60V 0 VA VA 5W 78V 60V 0 VA VA 0W 78V 60V 0 VA VA 0W 78V 60V 600 VA VA 0W 78V 60V Note: The above represent typical production test values and should not be interpreted as a guarantee of actual performance. Values may vary based upon control power transformer capacities. 600 VA VA 0W 78V 60V 00 VA 00 VA VA VA 300 VA 300 VA contactors will withstand 0% of their rated voltage continuously without injury to the operating coils and will close successfully at 65% of their rated voltage. Table -3. Mechanical Characteristics Sizes 6 Description Size Size Size 3 Size 4 Size 5 Size 6 Dimensions in Inches (mm) Height Width Depth Panel area, square inches Shipping weight, lbs. 6. (65.). (63.5) 4.96 (6.0) (65.). (63.5) 4.96 (6.0) (03.) 3.68 (93.5) 6.54 (66.) (03.) 3.68 (93.5) 6.54 (66.) (6.0) 7.07 (79.6) 7.64 (94.) (6.0) 7.07 (79.6) 7.64 (94.) Maximum cable size/phase copper AWG/MCM 8 AWG 4 AWG 0 MCM 0 MCM () 0 MCM () 0 MCM Auxiliary Electrical Circuits Available Maximum wire size for auxiliary electrical circuit AWG Maximum wire size for control circuit AWG () 4 () 4 () 4 () 4 () 4 () 4 Mechanical interlock combinations available Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Also referenced as kcmil (990 NEC) LA, Three-Phase AC Table -. Data from Table 430- of 990 NEC Horsepower Squirrel Cage AC V V V V /4 / 3/4 -/ / Note: These current values are for motors running at usual speeds and with normal torque characteristics. s for special low speed or high torque may require higher current. In all cases, OL trip current setting should be selected on basis of information on motor nameplate or motor card data Table -34. Temperature Specifications, Sizes 6 Ambient Temperature Storage - to 00 C (- to ) Operating - to C (- to 04 ) External (NEMA Enclosed) - to C (- to 04 ) Table -35. DIP Switch Overload Protection Settings Method Position 8 MANUAL (Non-automatic wait 5 minutes) 0 AUTOMATIC ( time is based on protection Class) Overload Class Position 7 Position None CA080E

8 ebruary 7 Technical Data and Specifications -9 Overload Current Settings ull Voltage Starters To select the overload current trip setting, find the starter size table. Locate the full load current from motor nameplate in column A or B. Change DIP switch positions 5 to correspond to the table. educed Voltage Starters Multiply the full load current from motor nameplate by factor below for your type of reduced voltage starter. ind this adjusted full load current in starter Size table in Column A or B. Change DIP switch positions 5 to correspond to the table. Table -36. actor W600 Autotransformer W700 Part Winding W800, W890 Wye-Delta Table -37. Size Lower Current ange Column A.5 to. Column B.0 Min. Max. Min. Max ating All settings not shown are equivalent to Auto/Man Class Control Voltage OL Set 3 P E C igure -7. DIP Switch, Terminals and Multiplier actor.0.5. DIP Switch Setting (Positions) (543) Table -38. Size Upper Current ange Column A.5 to. Column B.0 Min. Max. Min. Max All settings not shown are equivalent to Table -39. Size Current ange Column A.5 to Column B.0 Min. Max. Min. Max ating ating All settings not shown are equivalent to DIP Switch Setting (Positions) (543) DIP Switch Setting (Positions) (543) CA080E

9 - Technical Data and Specifications ebruary 7 Overload Current Settings (Continued) Table -30. Size 3 Current ange Column A.5 to. Column B.0 Min. Max. Min. Max All settings not shown are equivalent to Table -3. Size 4 Current ange Column A.5 to. Column B.0 Min. Max. Min. Max ating ating All settings not shown are equivalent to DIP Switch Setting (Positions) (543) DIP Switch Setting (Positions) (543) Table -3. Size 5 Current ange Column A.5 to. Column B.0 Min. Max. Min. Max All settings not shown are equivalent to Table -33. Size 6 Current ange ating All settings not shown are equivalent to DIP Switch Setting (Positions) (543) Column A.5 to. Column B.0 Min. Max. Min. Max ating DIP Switch Setting (Positions) (543) CA080E

10 ebruary 7 Technical Data and Specifications -3 Short Circuit atings Table -34. Short-Circuit atings Short-Circuit Protective Device (SCPD) Size Max. ating (SCPD) Circuit Breaker Interrupting ating Short-Circuit Withstand ating Current Voltage Typical Disconnect Device Class H use 60A 5,000A 30A DS Sw. Class J, or T use Only Thermal Only Type CB plus CL 60A 00,000A,000A 3A 00,000A 7A 00,000A 5A 00,000A 30A 00,000A A 00,000A 30A DS Sw. 00A D-K 00,000A S S HD DC 30A 00,000A plus CL Thermal/Mag. A,000A 00,000A HD plus CL Type CB plus CL Size Class H use 00A 5,000A 60A DS Sw. Class J, or T use Only Thermal Only Type CB plus CL 00A 00,000A,000A A 00,000A 90A 00,000A 60A DS Sw. 00A D-K 00,000A HD DC A 00,000A plus CL Thermal/Mag. 90A,000A 00,000A HD plus CL Type CB plus CL Size 3 Class H use 3A 5,000A 00A DS Sw. Class use A 00,000A Class J or T use Only Thermal Only Type CB plus CL Thermal/Mag. Type CB plus CL A 00,000A A 00,000A A 00,000A 00,000A 00A D-K 00A D-K HD DC 00A 00,000A plus CL A,000A 00,000A HD plus CL Short-Circuit Protective Device (SCPD) Size 4 Max. ating (SCPD) Circuit Breaker Interrupting ating Short-Circuit Withstand ating Current Voltage Typical Disconnect Device Class H use 0A 0,000A A DS Sw. Class J use 0A 00,000A Class or Class T use Only Thermal 0A 00,000A A 00,000A,000A 0A 00,000A 00,000A,000A 0A JD-K 0A JD-K JDC HJD Only A 00,000A plus CL Type CB plus CL Size 5 Class H use 600A 0,000A 0A KD-K Class J, or T use Only Thermal Size 6 Class J, or T use 600A 00,000A 0A 00,000A 0A 00,000A 0A,000A 00,000A 600A 00,000A Class L use 800A 00,000A Only Thermal 600A 00,000A 800A 600A 800A,000A HD KDC HKD 600A LD-K 600A LD-K Only HLD Thermal HMC Thermal/Mag. 800A,000A 00,000A NB Tri-Pac with CL Instantaneous adjustable trip. Circuit breaker. Inverse time circuit breaker. Instantaneous adjustable trip with current limiting attachment. Inverse time with built-in current limiting attachment. CA080E

11 ebruary 7 Control Modules -35 ull Voltage Pushbutton Control Module Metering Module Cutler-Hammer Control Modules (ACMs) from Eaton s electrical business provide a cost-effective alternative to pushbuttons, selector switches, indicating lights, reset mechanisms, bell alarms and panel meters when used with the product line. Typical input/output control functions provided by panel mounted devices are conveniently packaged in a series of modules depending on application and complexity. Sixteen styles cover applications ranging from: ull voltage non-reversing ull voltage reversing ull voltage multispeed educed voltage DeviceNet compatible Modules exist for each application to provide the functions of: Status only Indicating lights Status, STAT/STOP and ESET Status, HOA and ESET Status, STAT/STOP/HOA and ESET An additional Metering Module replaces conventional ammeters (three-phase), replaces reset mechanisms and displays trip cause and data, control voltage and status. This Metering Module can be used independently or in conjunction with any of the ACMs. An extra plug connection is available on the rear of each ACM to accept the Metering Module input. The ACM family has been designed to save: Panel space (versus conventional pushbuttons, selector switches and indicating lights) Mounting and assembly labor Wiring and installation time egardless of the configuration, installation requires mounting only one. x 3.5 inch module, substantially reducing space requirements. itting a standard Greenlee punch and die set, Greenlee #6007, installation is accomplished with only two screws. ACMs provide savings in wiring costs as well. egardless of the complexity of the application, wiring is reduced to a single plug-in cable, see photo at left. Communication is not restricted by use of the Control Modules. An extra plug connection is available on the rear of the ACM or Metering Module to allow a WPONIDNA or WPONI Communications module to be plugged in.. (57.) un Status Only ES OL Alarm OL 3.5 (88.9) un STAT STOP ES STAT/STOP Control OL Alarm OL igure -76. ull Voltage and educed Voltage Control Modules ull Voltage and educed Voltage Control Modules Status Only 4 LEDs indicate that the motor is O, unning, ped or in Alarm mode (motor current is above the trip current setting) Includes ESET button STAT/STOP STAT/STOP controlled by STAT and STOP buttons Includes all features of Status Only module HOA Selector Switch with STAT/STOP In HAND mode, motor will start and stop in response to STAT/STOP pushbuttons In AUTO mode, motor will run in response to remote signal Includes all features of Status Only module ON/O/AUTO Selector Switch will run in ON mode and not in the O mode In AUTO mode the motor will run in response to a remote signal Includes all features of Status Only module educed Voltage Control Modules The four reduced voltage pushbutton control modules provide control using two to four starters and/or contactors. The faceplates are identical to the full voltage modules, and the pushbuttons all perform the same functions. The module is programmed for the type of reduced voltage starter which sets the sequence of contact open and closing. un HAND O AUTO ES OL Alarm OL STAT STOP un ON O AUTO ES OL Alarm OL HAND/O/AUTO Control ON/O/AUTO with STAT/STOP Pushbutton Control Control in HAND Mode CA080E

12 -36 Control Modules ebruary 7 eversing and -Speed Pushbutton Modules 3.5 (88.9) un wd un ev un wd un ev. (57.) ES OL Alarm OL Status Only ES OL Alarm OL STAT/STOP Control Status Only 5 LEDs which indicate that the motor is O, running forward (AST), running reverse (SLOW), tripped or in alarm mode Includes ESET button OWAD (AST)/EVESE (SLOW)/STOP Pushbuttons control whether motor is running forward (AST), running reverse (SLOW) or stopped Includes all features of Status Only module Metering Module The Metering Module monitors status of a motor along with any of the pushbutton modules. It may be plugged into the pushbutton control module, and communicates to the starter through it, or plugged directly into the starter when a pushbutton control module is not used. The four digit display will show the current in each phase, control voltage or cause of trip. The STEP button may be pressed to step through these values, and the five LEDs will indicate which value is being displayed. It is also equipped with a reset button and Lockout LED. WD EV STOP un wd un ev O AUTO ES OL Alarm OL WD EV STOP HAND WD/EV/O/ AUTO Control igure -77. eversing and -Speed Pushbutton Module ACM Specifications Input supply requirements: 0V AC (supplied by the motor controller) Max. distance from motor controller: 6 ft. (.83m) Operating frequency: or 60 Hz Operating temperature: -0 to 70 C Storage temperature: -0 to 85 C Humidity: 0 to 95%, non-condensing emote input wire size: 8 4 AWG Maximum distance between remote pushbuttons and ACM: ft. (60.9m) Cutout dimensions:. x 3.5 inches (57. x 88.9 mm) (see above). The cutout can be made using a Greenlee rectangular punch #60070 Enclosure type: NEMA or, when properly installed WD/EV/O/AUTO In AUTO mode, motor is running forward (AST), running reverse (SLOW) or O in response to a remote signal All features of OWAD/EVESE/ STOP module Note: or -speed modules, AST replaces WD and SLOW replaces EV. Table -9. Control Modules/Accessories Description ull Voltage Status Only with STAT/STOP STAT/STOP/HOA ON/O/AUTO LOCAL/O/EMOTE with Lockable ACM LOCAL/O/EMOTE with Network Health eversing Status Only with WD/EV/STOP WD/EV/STOP/HOA -Speed Status Only with AST/SLOW/STOP AST/SLOW/STOP/HOA educed Voltage Status Only with STAT/STOP STAT/STOP/HOA ON/O/AUTO Metering Module 0 ft. Interconnect Cable (3m) 6 ft. Interconnect Cable (.8m) 3 ft. Interconnect Cable (.9m) ft. Interconnect Jumper (.3m) WPBV WPBV WPBV3 WPBV4 WPBV5 WPBV7 WPB WPB WPB3 WPBS WPBS WPBS3 WPBV WPBV WPBV3 WPBV4 WMETE WACM0 WACM6 WACM3 WACM The WPBV5 and WPBV7 are DeviceNet only. They can only be used when an active network is connected. Harmonic distortion may cause the WMETE to display inaccurate current measurements. Discount Symbol CDC CA080E

13 ebruary 7 Wiring Diagrams -43 Non-reversing and eversing Contactors, NEMA Sizes 6 T3 L L M T T L L T3 T T H X No Connection When Start/ Pushbutton Used H X Start Start 3 Emergency 3 P M E C H X H X M Hand Automatic emote Control Device Emergency Jumper 3 P M E C Mb Ma G ped unning Mb Ma G ped unning Cat. No. W0 Non-reversing Contactor 3-Wire Control with Internal Holding Circuit Cat. No. W0 Non-reversing Contactor -Wire Control with Maintained HOA Switch Conductors External to Baseplate Are Installer Connections = Accessible Terminals m and m Are Electrical Contacts Operated by the Mechanical Interlock orward everse ped G Emergency 3 Start P un Permit / E Power C Common Emergency (Dashed Area) Mechancial Interlocks 3PEC 3PEC m Electrical Interlocks m L X H X H L L L wd ev E C m 3 Start P un Permit / E Power C Common 3PEC 3PEC Electrical Interlocks m Mechanical Interlock Baseplate with Components as Supplied G ped everse orward E C Baseplate with Components as Supplied T T T3 T T T3 T T T3 T3 T T L L X H L L X H wd ev m and m Are Electrical Contacts Operated by the Mechanical Interlock Cat. No. W Vertical eversing Contactor 3-Wire Control with Internal Holding Circuit Cat. No. W Horizontal eversing Contactor 3-Wire Control with Internal Holding Circuit igure -84. Typical Wiring Diagrams Sizes 5 and 6 horizontal reversing contactors have their orward and everse contactor arrangement reversed. everse contactor is on left and orward contactor is on right. CA080E

14 -44 Wiring Diagrams ebruary 7 Non-reversing and eversing Starters, NEMA Sizes 6 T3 L L H X No Connection When Start/ Pushbutton Used Mb Ma H X M Start 3 G Start Emergency ped unning 3 P M E C T T Ind./ (When Used) (Current Sensors Are Integral Inside Starter Units) L L H X Ma H X M Start 3 Emergency Mb G ped unning 3 P M E C T3 T T Ind./ (When Used) (Current Sensors Are Integral Inside Starter Units) PONI I Mod. I Caution Unplug IMPACC Plug During Maintenance To Other IMPACC Network Devices To IMPACC Network PC Cat. No. W Non-reversing Starter 3-Wire Control with Internal Holding Circuit Cat. No. W Non-reversing Starter Internal Holding Circuit, 3-Wire with IMPACC Conductors External to Baseplate Are Installer Connections = Accessible Terminals m and m Are Electrical Contacts Operated by the Mechanical Interlock 98 orward everse ped ped G A Emergency 3 Start P un Permit / E Power C Common Emergency (Dashed Area) Mechanical Interlock 3PEC 3PEC m Electrical Interlocks m L X H X H L L L To IMPACC/INCOM Network wd ev () Lighted Also Available () May Also Be Added to orward & everse Contactors WPONI Mod E C Contacts Shown in Energized State OL EC m 3 Start P un Permit / E Power C Common 3PEC 3PEC Electrical Interlocks m L L Mechanical Interlock X H Baseplate with Components as Supplied L L X H G A ped ped everse orward 98 wd ev E C E C Contacts Shown in OL Energized State WPONI Mod. () Lighted Also () Available May Also Be Added to orward & everse Contactors Baseplate with Components as Supplied T T T3 To IMPACC/INCOM Network T T T3 T T T3 T T T3 Cat. No. W0 Vertical eversing Starter 3-Wire Control with Internal Holding Circuit Cat. No. W0 Horizontal eversing Starter 3-Wire Control with Internal Holding Circuit igure -85. Typical Wiring Diagrams Sizes 5 and 6 horizontal reversing contactors have their orward and everse contactor arrangement reversed. everse contactor is on left and orward contactor is on right. CA080E

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6 Revision D Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6 Size 2 Size 3 Fig. 1 Type W Standalone Overload Relays Size 5 THE OVERLOAD RELAYS Advantage Type W three phase,

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai Lin, Professor

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

SECTION MOTORS & MOTOR CONTROLLERS

SECTION MOTORS & MOTOR CONTROLLERS SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Product Description. Application Description

Product Description. Application Description -2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type

More information

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

NEMA Full Voltage Power Devices. Section 1.  Control Catalog 1-1 NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Motors  GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2 GRUNDFOS GROUNDWATER SERVICE MANUAL Motors 4-6-8-10" CONTENTS Grundfos Motor Specifications... Page 2 Electrical Requirements... Page 8 -Transformer Capacity Maximum Motor Cable Length... Page 10 Full

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 262913 - ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Programmable Logic Controller. Mat Nor Mohamad

Programmable Logic Controller. Mat Nor Mohamad Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could

More information

IEC Contactors & Starters. (IT.) Electro-Mechanical

IEC Contactors & Starters. (IT.) Electro-Mechanical March 2008-223 Contents Description Page Product Family Overview Product Description...... -218 Standards and Certifications.......... -218 Publications............ -218 Selection............. -219 s and

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents June 5 Vol. 2, Ref. No. [067] -1 Reduced Voltage Motor Starters Contents Description Page Solid-State Controllers Type S701, Soft Start.......................................... -2 Type TL, Torque Limiter........................................

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 MOTOR CONTROLLERS SPEC WRITER NOTE: Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1 Cl November 1984 New Information Mailed to: E, D, C/29-900A Westinghouse Electric Corporation Distribution and Protection Business Unit Commercial Division - Assemblies London, KY 407 41 Technical Data

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

Technical Section: Miniature Circuit Breakers

Technical Section: Miniature Circuit Breakers MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Electric Motor Controls BOMA Pre-Quiz

Electric Motor Controls BOMA Pre-Quiz Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Open Chassis Star-Delta Starter User Guide

Open Chassis Star-Delta Starter User Guide Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES FILE 29-900 Instructions for Combination Bypass Isolation and Transfer Switches 100-1000 Amps APPLICATION The Cutler-Hammer combination Bypass Isolation and Transfer Switches are listed under Underwriters

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Motor Protection Fundamentals. Motor Protection - Agenda

Motor Protection Fundamentals. Motor Protection - Agenda Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Low Voltage Fuses For Motor Protection

Low Voltage Fuses For Motor Protection Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.

More information

PATTERSON PUMP COMPANY

PATTERSON PUMP COMPANY PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation MATRIX FILTER SERIES D 480 Volts, 60HZ USER MANUAL PART NO. INSTR 024 REL. 120628 REV. 012 2012 MTE Corporation Matrix Series D User s Manual 480VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

AIR COOLED RECTIFIER SPECIFICATION S-50-A

AIR COOLED RECTIFIER SPECIFICATION S-50-A SPECIFICATIONS AIR COOLED RECTIFIER Spec50a1 5JAN1999 SPECIFICATION S-50-A HIGH VOLTAGE SINGLE TRANSFORMER AIR COOLED RECTIFIER Standard output power range: 250 to 600 volts at 100 to 1,200 amperes TECHNICAL

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information