SAFETY EQUIPMENT Safety Equipment for Railway Systems

Size: px
Start display at page:

Download "SAFETY EQUIPMENT Safety Equipment for Railway Systems"

Transcription

1 Product Catalogue SAFETY EQUIPMENT Safety Equipment for Railway Systems

2 Information concerning this catalogue: All rights reserved for copying of any kind. All dimensions and pictures are not binding. We permanently strive to improve products and reserve the right to change design, dimensions or material.

3 Contents General List of Type Numbers 4 Introduction 5 Earthing components Phase clamps 8 Clamps for contact wires 10 Earthing clamps 12 Rail earthing clamps 14 Earthing and short-circuiting cables 16 Ball point connectors 17 Earthing rods Telescopic earthing rods 18 Plug-in earthing rods 19 Earthing systems Earthing systems for contact wires (profile-free devices) 20 Earthing systems for contact wires (non profile-free devices) 22 Earthing system for feeder lines 27 Earthing system for pylons at rail tracks 28 Earthing systems for construction machinery 29 Bridging devices for rails 30 High voltage detectors ARCUSDETECT M - High voltage detector for contact wires and feeder lines 31 ARCUSDETECT M - High voltage detector for railway networks 32 ARCUSDETECT M - High voltage detectors for substations 33 Accessories Carrying bags 34 Carrying cases 36 Suspension hooks (for profile-free earthing) 37 Wall holders 38 Storage systems 39 Underground railway systems Earthing devices for underground railway systems 40 Earthing rack 42 Clamps for current rails 43 Earthing system with earthing cable and clamps 44 Tram Feeding rod for traction current 45 3

4 List of Type Numbers Type Number Page Type Number Page Type Number Page General

5 Introduction Dear reader! Work in or at electric railway installations requires a number of safety steps to minimise or eliminate dangers caused by moving rail vehicles or by electric current. Such safety steps are not always carried out by employees of the railway company, but in emergency cases also by fire brigades or other rescue workers. General Special importance is given to the clear marking of working limits, as well as a permanently secured absence of voltage within these working limits. Specially in train stations with unclear criss-crossing of lines, or on open railtrack with a number of lines running in parallel over long distances and influencing each other, securing the working place is essential. Also the subject of visibility has importance as in many cases an earthing device at the same time marks the working limit. Under any circumstance this working limit needs to be clearly visible, not only at daylight, but also at night, in tunnels, or when a number of pylons and lines in the background make recognition of an earthing rod difficult. Frequently work needs to be carried out during train operation hours, in often very short intervalls without trains, so handling of material is rough. Material will be more strained than from similar operations in utility networks, wear is considerable, and at the same time concessions towards reliability are to be excluded. 5

6 Introduction General High voltage detectors which are to be handled with care as a safety-relevant measuring device, have to withstand many downfalls into the stony roadbed. Earthing material which needs to be carried to the working place over long distances may already suffer superficial damages, but these must not compromise its usage. In order to meet these special requirements, railway material in most cases has its own standards. One example among others is the standard for high voltage detectors for catenary wires (contact wire detector), or the fact that for earthing material higher final temperatures in case of a short circuit are admissible. This way cross-sections of copper leads can be restricted, to make an earthing device portable even over longer distances. In the course of many years a multitude of different products for testing absence of voltage, earthing and short-circuiting, potential equation, and for marking working limits were developed in cooperation with German Railway DB, Austrian National Railways ÖBB, Swiss National Railways SBB, Belgian Railway SNCB, and other European rail companies. Before a product may be named railway material, it has to fulfill requirements demanded by the user, and in many cases pass a practical test over several weeks, to finally pass a formal approval procedure by the customer. 6

7 Introduction This catalogue will give you an overview about our programme of safety equipment for railway systems. We have arranged these products in different groups to facilitate identification. All important details are listed in a table and supported by pictures. General In case of uncertainties how to find a product or how to select a suitable one, please contact us. You will find our contact details on the backside of this catalogue. ARCUS Schiffmann offers you not only a vast range of safety equipment for railway systems, but furthermore will be pleased to support you in selecting the suitable products. This service is a matter of course for us! 7

8 Earthing Components Phase clamps Picture shows ARCUS phase clamps are suitable for connection to round and flat conductors, ball point and T-bolt connectors. All phase clamps are provided with a spindle shaft according to DIN Construction of phase clamps enables removal of foreign layers (soiling, corrosion) from contact areas. Simple and safe clamping to conductor by fastening with screw thread method. Phase clamp Clamping range Connection bolt Lead cross section [mm²] DB-Material-No. Type Number Round Ø 5-35 mm M12 max Round Ø mm M12 max Flat up to 20 mm, round Ø 9-22 mm, T-bolts up to 20 mm max. 120 M12 Ball point connectors up to Ø 25 mm max

9 Earthing Components Type No Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Type No Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Type No With test strip to determine absence of voltage Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Test strip: Galvanised steel 9

10 Earthing Components Clamps for contact wires Picture shows Picture shows ARCUS clamps for contact wires are suitable for a number of figure-eight wires, round and double contact wires. All clamps for contact wires are provided with a test strip to determine absence of voltage and a catch device for use as installation aid. All clamps for contact wires are provided with a spindle shaft according to DIN Construction of clamps for contact wires enables removal of foreign layers (soiling, corrosion) from contact areas of contact wire. A disc spring package (not in type no ) secures a constant, high and vibration-proof contact force. Simple and safe installation on contact wire by screw thread method. A separate electric connection of the pressure piece secures optimum current tapping from contact wire. Clamps for Contact Wires Contact wire Connection bolt Lead cross section [mm²] DB-Material-No. Type Number Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Single and double contact wire SNCB M12 max

11 Earthing Components Type No With rigid bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type No With elongated (+5 mm) and rigid bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type No With compact test strip and catch device Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Stainless steel Type No With elongated and flexible bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type No Single and double contact wire SNCB Material (contact parts): Strap: Aluminium alloy, tin-plated Pressure piece: Aluminium alloy, tin-plated Test strip: Stainless steel Catch device: Hot-dip galvanised steel 11

12 Earthing Components Earthing clamps Picture shows Picture shows ARCUS earthing clamps are suitable for a multitude of pylon constructions. Clamp bodies are made of high-strength copper alloy or aluminium alloy. All earthing clamps are provided with conical top or serrated surface made of tempered material (except type no ) to cut through foreign layers (soiling, corrosion, varnish). Simple and safe installation by screw thread method. Earthing clamp Type No. Clamping range Connection bolt Lead cross section [mm²] DB-Material-No. Flat up to 24 mm M12 max Flat up to 24 mm M12 max Flat up to 24 mm M12 max Flat up to 20 mm, round Ø 9-22 mm, T-bolts up to 20 mm max. 120 M12 Ball point connectors up to Ø 25 mm max

13 Earthing Components Type No With hand screw for simple and safe installation, and anti-twist groove on cable lug connection. Material (contact parts): Contact plate: tempered steel, tin-plated Pressure piece: tempered steel, tin-plated Type No With hand screw and shortened spindle for simple and safe installation, and anti-twist groove on cable lug connection. Material (contact parts): Contact plate: tempered steel, tin-plated Pressure piece: tempered steel, tin-plated Type No With grooved circular top for optimum piercing through foreign layers. Material (contact parts): Grooved top: Stainless steel Centring tip: Stainless steel Type No With plastic handle for simple and safe installation, and anti-twist groove on cable lug connection. Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated 13

14 Earthing Components Rail earthing clamps Picture shows Picture shows ARCUS rail earthing clamps are suitable for a number of different rail profiles. Based on the construction of the rail earthing clamps, foreign layers and especially corrosion are pierced or part-removed from rail foot or rail head, so that an optimum mechanic and electric contact is obtained. Simple and safe installation on rails. Rail foot earthing clamp (profile-free earthing) Rail profile Connection bolt Lead cross section [mm²] DB-Material-No. Type Number UIC 60 M12 max S 49, S 54, S 64, UIC 60 M12 max SNCB (50 T, UIC 60, A74/UIC 60A, 63 T) M12 max S 49, S 54, S 64, UIC 60 M12 max S 49, S 54, S 64, UIC 60 M12 max Rail head earthing clamp (non profile-free earthing) Type Number Rail profile Connection Lead cross section [mm²] DB-Material-No. SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 M10 (special cable connection) max SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 Ball point connector Ø 25 mm max

15 Earthing Components Rail foot earthing clamps (profile-free earthing) Type No With undetachable ratchet for comfortable and safe installation. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type No With hand screw for simple and safe installation. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type No With undetachable ratchet for comfortable and safe installation, especially suitable for heavily corroded rails. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type No With connection to ratchet 1/2 square-end. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type No With hand grip, for distance rail to concrete of max. 20 mm. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Rail head earthing clamps (non profile-free earthing) Type No With hand screw for simple and safe installation. Material (contact parts): Top pressure piece: Copper alloy, tin-plated Bottom pressure piece: laminated fabric with glassfibres Type No With hand screw for simple and safe installation, with ball point connector Ø 25 mm. Material (contact parts): Top pressure piece: Copper alloy, tin-plated Bottom pressure piece: laminated fabric with glassfibres 15

16 Earthing Components Earthing and short-circuiting cables Picture shows All earthing cables meet the required tension test values of IEC d1 d2 Earthing cables are made of highly-flexible copper lead with a cross section of 50 mm², with PVC-coating. Transitions from cable lug to lead coating are enclosed by a stabilising, tenacious elastic transparent sleeve. This mechanic kinking protection guarantees a reliable sealing against moisture ingress. Transparency of insulation enables visibility of copper leads up to the copper cable lug barrel, so that damages of strands caused by ageing can be identified early. Carrying bag page 34 and following. Earthing and short-circuiting cables Cable length [mm] Lead cross section [mm²] d1 [mm] Palm hole Red flags DB-Material-No. d2 [mm] Type Number Further models available upon request. 16

17 Earthing Components Ball point connectors Picture shows Safe usage on numerous established pylon constructions of electric railways. Ball point connectors made of high-strength copper, tinplated, nuts and washers made of galvanised steel. Picture shows Type No DB-Material-No Earthing bar made of copper with 2 ball point connectors Ø 25 mm, firmly connected to an earthing clamp for ball point connectors Ø 25 mm. This multiple earth connection takes up 2 one-polar short-circuiting cables. Type No Earthing bar made of copper with 3 ball point connectors Ø 25 mm, firmly connected to an earthing clamp for ball point connectors Ø 25 mm. Picture shows Type No DB-Material-No Ball point connector Ø25 mm, thread: M16x47 mm Material: Ball point connectors made of high-strength copper, tin-plated, nuts and spring washers made of galvanised steel. Type No DB-Material-No Ball point connector Ø25 mm, thread: M16x27 mm Type No DB-Material-No Earthing plate with 2 ball point connectors Ø 25 mm Type No DB-Material-No Earthing plate with 1 ball point connector Ø 25 mm Palm hole: Ø 12.5 mm Further models available upon request. 17

18 Earthing Rods Telescopic earthing rods Picture shows All extendable earthing rods are designed for the requirements of earthing and short-circuiting electric contact wires. They are used to guide one-polar devices to catenaries, feeders, and traction power lines. LT LG Depending on requirements on transport length, these earthing rods are available in 2- or 3-section versions. For better visibility in the track area, some of these earthing rods are provided with red marks on the lower rod part. Coupling heads are suitable to take up phase clamps (page 8) and clamps for contact wires (page 10) which have a spindle shaft to DIN The earthing rods are equipped with couplings. This enables varied usage lengths until stop at full extension. Type nos and are provided with a hand protection disc instead of a black ring. Carrying bags, cases and wall holders, see page 34 and following. Telescopic earthing rods LG [mm] LT [mm] Coupling head n-parts DB-Material-No. Type Number Safety bayonet head Safety bayonet head with locking function Safety bayonet head with locking function Aluminium bayonet Aluminium bayonet Safety bayonet head with locking function Safety bayonet head with locking function Safety bayonet head with locking function Further models available upon request. 18

19 Earthing Rods Plug-in earthing rods Picture shows LT All plug-in earthing rods are designed for the requirements of earthing and short-circuiting electric contact wires. They are used to guide one-polar devices to catenaries, feeders, and traction power lines. LG Due to short transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Depending on the total length required, these earthing rods consist of 5 or 7 parts. For better visibility in the track area, these earthing rods are provided with red marks on the lower rod part. Compact coupling heads are suitable to take up phase clamps (page 8) and clamps for contact wires (page 10) which have a spindle shaft to DIN These earthing rods are equipped with very robust couplings. Carrying bags, cases and wall holders, see page 34 and following. Plug-in earthing rods LG [mm] LT [mm] Bag Coupling head n-parts DB-Material-No. Further models available upon request. Type Number Safety bayonet head with locking function Safety bayonet head with locking function Safety bayonet head with locking function ) Safety bayonet head with locking function ) with cable decoiler on mid-section 19

20 Earthing Systems Earthing systems for contact wires (profile-free devices) 4 Safe usage on numerous established pylon constructions of electric railways. Easy to maintain and repair. Warning flag or other colour markings for clear visibility of device. Carrying bags, cases and wall holders, see page 34 and following. Type No SBB-No Telescopic earthing rod (3-section) with safety rod head and take-up devices for cable and earthing clamp Total length: 5770 mm; Transport length: 2320 mm Earthing and short-circuiting cable, 50 mm², mm long Clamp for contact wires Type No (page 10) Earthing clamp Type No (page 12) Suspension hook and cable guidance for installation on pylon Type No (page 37) Warning flag for clear visibility of earthing device Device suitable for: Contact wire: Ri (DIN ); Ø mm Earth connection: Flat up to 24 mm Further models available upon request. 20

21 Earthing Systems Earthing systems for contact wires (profile-free devices) Type No DB-Material-No Earthing and short-circuiting cables with 3 red flags, 50 mm², mm long Type No (page 16) Clamp for contact wires Type No (page 10) Rail foot earthing clamp Type No (page 14) Suspension hook and cable guidance for installation on pylon Type No (page 37) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type No DB-Material-No Telescopic earthing rod (2-section) with safety rod head Type No (page 18) Earthing and short-circuiting cables with 3 red flags, 50 mm², mm long Type No (page 16) Clamp for contact wires Type No (page 10) Rail foot earthing clamp Type No (page 14) Suspension hook and cable guidance for installation on pylon Type No (page 37) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 21

22 Earthing Systems Earthing systems for contact wires (non profile-free devices) 4 Safe usage. Easy to maintain and repair. Warning flag or other coloured markings for clear visibility of device. Carrying bags, cases and wall holders, see page 34 and following. Type No DB-Material-No Due to favourable transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Pluggable earthing rod (5-part) with safety rod head and tubular bag Type No (page 19) Earthing system Type No (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Earth connection: Flat up to 24 mm 22

23 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type No x Earthing and short-circuiting cables with 3 red flags, 50 mm², 8500 mm long Type No (page 16) 2x Clamp for contact wires Type No (page 10) 2x Rail foot earthing clamp Type No (page 14) Carrying bag for cables Type No (page 35) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type No Earthing and short-circuiting cable with 3 red flags, 50 mm², 8500 mm long Type No (page 16) Clamp for contact wires Type No (page 10) Rail foot earthing clamp Type No (page 14) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 23

24 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type No DB-Material-No Telescopic earthing rod (2-section) with safety rod head Type No (page 18) Earthing system Type No (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type No Pluggable earthing rod (2-part) with fixed phase clamp similar to type no (page 8) and take-up devices for cable and earthing clamp Total length: 4600 mm; Transport length: 2600 mm Earthing and short-circuiting cable, 95 mm², 4600 mm long Earthing and short-circuiting cable, 95 mm², 1500 mm long 2x Rail head earthing clamp Type No (page 14) Warning flag for clear visibility of earthing device Device suitable for: Conductor: Round Ø mm Rail: SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 24

25 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type No SBB-No Pluggable earthing rod (2-part) with fixed clamp for contact wire similar to type no (page 10) and take-up device for cable and earthing clamp Total length: 4600 mm; Transport length: 2600 mm Earthing and short-circuiting cable, 50 mm², 4600 mm long Earthing and short-circuiting cable, 50 mm², 1500 mm long 2x Rail head earthing clamp Type No (page 14) Warning flag for clear visibility of earthing device Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 25

26 Earthing Systems Earthing systems for contact wires (non profile-free devices) Usage: Due to favourable transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Carrying bags, cases and wall holders, see page 34 and following. Type No Telescopic earthing rod (3-section) with safety rod head Type No (page 18) Earthing system Type No (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 26

27 Earthing Systems Earthing system for feeder lines Carrying bags, cases and wall holders, see page 34 and following. Type No Earthing and short-circuiting cable, 50 mm², 4000 mm long, Type No (page 16) Phase clamp Type No (page 8) Earthing clamp Type No (page 12) Device suitable for: Conductor: Ø 6-35 mm Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm 27

28 Earthing Systems Earthing system for pylons at rail tracks Usage: Earthing device for pylons at rail tracks (potential equalisation). Carrying bags, cases and wall holders, see page 34 and following. Type No Earthing and short-circuiting cable, 50 mm², 4000 mm long Type No Rail foot earthing clamp Type No (page 14) Earthing clamp Type No (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm Further models available upon request. 28

29 Earthing Systems Earthing systems for construction machinery Picture shows Usage: Protective earth for construction machinery. Carrying bag page 34 and following. Type No DB-Material-No Earthing and short-circuiting cable, 50 mm², mm long Type No (page 16) Rail foot earthing clamp Type No (page 14) Earthing clamp Type No (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm Type No Earthing and short-circuiting cable, 50 mm², mm long Type No (page 16) Rail foot earthing clamp Type No (page 14) Earthing clamp Type No (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm 29

30 Bridging Devices for Rails Picture shows Usage: Earthing device for bridging running rails (potential equalisation). Type No Earthing and short-circuiting cable, 95 mm², 1600 mm long 2x Rail foot earthing clamp Type No (page 14) Carrying bags, cases and wall holders, see page 34 and following. Type No Earthing and short-circuiting cable, 95 mm², mm long 2x Rail foot earthing clamp Type No (page 14) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Device suitable for: Rail: S 49, S 54, S 64, UIC 60 30

31 ARCUSDETECT M - High Voltage Detector for Contact Wires and Feeder Lines Usage: This high voltage live line detector tests absence of voltage on catenaries with single-phase a.c. of Un=15 kv and nominal frequency of 16.7 Hz. 4 Suitable for outdoor use. Visual indication Self-test including test electrode (VGS)* Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% LG LH LI LV Carrying bag included Material (main parts) Test electrode: Aluminium tin-plated Contact electrode extension: Synthetic tube, Ø 21 mm Casing: Polyamide Insulating rod: Synthetic tube, Ø 24 mm * VGS (fully-tested electrode): Test electrode is included in self-test by means of parallel conductor loops inside contact electrode extension. High voltage detector according to DIN VDE 0681 part 6 for contact wires and feeder lines U n [kv] f [Hz] LG [mm] LV [mm] LI [mm] LH [mm] Transport length [mm] Type Number Further models available upon request. 31

32 ARCUSDETECT M - High Voltage Detector for Railway Networks Usage: This high voltage live line detector tests absence of voltage on railway networks with singlephase a.c. of Un=15 kv and nominal frequency of 16.7 Hz. * VGS (fully-tested electrode): Test electrode is included in self-test by means of parallel conductor loops inside contact electrode extension. 4 Suitable for outdoor use. Visual indication Self-test including test electrode (VGS)* Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% Threaded fork contact for overhead lines Transport eye for carabiner LO LH Li Ai Carrying bags, cases and wall holders, see page 34 and following. Material (main parts) Test electrode: Aluminium tin-plated Contact electrode extension: Synthetic tube, Ø 21 mm Casing: Polyamide Insulating rod: Synthetic tube, Ø 24 mm Fork contact: Copper tin-plated High voltage detector basically to IEC for railway networks U n [kv] f [Hz] LO [mm] Ai [mm] Li [mm] LH [mm] Transport length [mm] DB-Material-No. Type Number Further models available upon request. 32

33 ARCUSDETECT M - High Voltage Detectors for Substations Usage: This high voltage live line detector tests absence of voltage in substations with nominal frequency of 16.7 Hz. 4 Suitable for outdoor use. Audible and visual indication Self-test including test electrode (VGS)* Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% LO LH Li Ai Carrying bags, cases and wall holders, see page 34 and following. Material (main parts) Test electrode: Aluminium tin-plated Contact electrode extension: Synthetic tube, Ø 21 mm Casing: Polyamide Insulating rod: Synthetic tube, Ø 24 mm * VGS (fully-tested electrode): Test electrode is included in self-test by means of parallel conductor loops inside contact electrode extension. High voltage detector basically to IEC for substations and overhead lines (detector for one nominal voltage) U n [kv] f [Hz] LO [mm] Ai [mm] Li [mm] LH [mm] Transport length [mm] Type Number High voltage detector basically to IEC for substations and overhead lines (detector for a nominal voltage range) U n [kv] f [Hz] LO [mm] Ai [mm] Li [mm] LH [mm] Transport length [mm] Type Number Further models available upon request. 33

34 Accessories Carrying bags Picture shows Tubular bags Design: Polyester, royal blue 2x belt strap black 1 shoulder strap Lid with zipper Inside with transparent pocket for instruction for use Dimensions [mm] Type Number Ø 150x820 long Ø 150x1020 long Ø 150x1100 long Ø 150x1220 long Ø 150x1320 long Ø 150x1420 long Ø 150x1520 long Ø 150x1620 long Ø 150x1720 long Picture shows Tubular bags Design: Cotton cloth, olive coloured Anti-fouling, water-repellent 2x belt strap black 1 shoulder strap String closure Dimensions [mm] Type Number Ø 200x1800 long Ø 200x2200 long Ø 200x2400 long Further models available upon request. 34

35 Accessories Carrying bags Picture shows Carrying bags Design: Tarpaulin, royal blue 1x belt strap black With belt closure Inside with transparent pocket for instruction for use Suitable for 2-part high voltage detectors H [mm] L [mm] Pockets Type Number Carrying bags for cables Type No Design: Tarpaulin, royal blue 2x belt strap black With zipper Inside with transparent pocket for instruction for use Dimensions [mm]: WxDxH: 420x120x420 Picture shows Wrapping bag Design: Tarpaulin 1x belt strap black With belt closure Inside with transparent pocket for instruction for use H [mm] L [mm] Pockets Colour Type Number grey royal blue royal blue royal blue Further models available upon request. 35

36 Accessories Carrying cases Picture shows Carrying case for high voltage detectors Basic version: Shell of plastic material with foamed inlay Outside dimensions H [mm] W [mm] D [mm] Type Number Picture shows Carrying case for high voltage detectors Robust model: Shell of rigid plastic material with aluminium frame and foamed inlays Outside dimensions H [mm] W [mm] D [mm] Type Number

37 Accessories Suspension hooks (for profile-free earthing) Type No For profile-free earthing of catenaries, a suspension hook is required. This way the earthing and short-circuiting cable is fixed at the pylon at a distance from the railtrack (see page 21). Type No For profile-free earthing of catenaries, a suspension hook is required. This way the earthing rod is fixed at the pylon at a distance from the railtrack (see page 20). 37

38 Accessories Wall holders For storage of high voltage detectors, operating rods and earthing rods Easy and fast installation with 2 screws. Wall holders are made of very strong plastic material. Type No For insulating rods with tube diameter Ø mm Type No For insulating rods with tube diameter Ø mm Type No For insulating rods with tube diameter Ø mm 38

39 Accessories Storage systems Picture shows Storage brackets help to prevent material damage during storage of earthing and shortcircuiting device and earthing rods. To protect the highly flexible earthing cables, the contact areas of the bracket are rounded. Storage brackets are available in two sizes, and alternatively in plastic or sheet steel material. A clip made of spring steel takes up one earthing rod (for outside tube diameters of Ø mm). H W D 50 Bracket with clip for earthing rod H [mm] W [mm] D [mm] Material Type Number plastic steel, plastic-coated Bracket only (no clip) H [mm] W [mm] D [mm] Material Type Number plastic steel, plastic-coated

40 Earthing Devices for Underground Railway Systems Usage: These ARCUS short circuiting devices are suitable for earthing and short circuiting underground railtracks with voltages up to 1 kv. These devices are kept in trains, stored in train stations, but can also be found in fire brigade vehicles. Material (contact parts): Running rail contact: Aluminium alloy Current rail contact: Electrolytic copper Earthing cable: Copper lead, PVC-insulated Tension spring storage: Galvanised steel Jointing and fixing parts: Galvanised steel Frame: Synthetic tube, glassfibre-reinforced Underground railway systems Electric short-circuiting capacity: Type No at 700 V DC: as earthing device: (energise when device is placed in position) -short circuit current 30.5 ka -overall time approx. 23 ms as short-circuiting device: (to short circuit a live railtrack) -short circuit current 28.5 ka -overall time approx. 23 ms Type No at 750 V DC: as earthing device (energise when device is placed in position) and as short-circuiting device (to short circuit a live railtrack) -short circuit current 100 ka -overall time approx. 35 ms Further information can be found in our Technical Information Short-Circuiting Device for Underground Railways. 40

41 Earthing Devices for Underground Railway Systems Construction for power supply from top side Construction for power supply from bottom side C B C Selection of types: Type A Design B [mm] C [mm] Rail track system Type Number Type A , 76, 116 Siemens Wildenrath, Germany Type A Berlin, Germany Type A Rotem, Korea Type A Athen, Greece Type B Hamburg, Germany Type B Rotterdam, the Netherlands Type B Rotterdam, the Netherlands Type B Berlin, Germany Type B Docklands, Great Britain Type B Taipei, Taiwan Type B Munich, Germany Type B Munich, Germany Type B Vienna, Austria Type B Prague, Czech Republic Type B Amsterdam, the Netherlands Type B Amsterdam, the Netherlands Type B Stockholm, Sweden Type B Singapore Type B Helsinki, Finland Type B Rotem, Korea Type B Bangkok, Thailand Type B Berlin, Germany B Type B Underground railway systems Further information can be found in our Technical Information Short-Circuiting Device for Underground Railways. 41

42 Earthing Rack Usage: The earthing rack serves as earth connection for current rails of underground train systems. The rail profile remains free so that diesel traction vehicles can pass. On the earth side, the earthing rack is connected to an earthing cable and an earthing clamp. Earthing clamp and length of earthing cable are supplemented individually to customer s request. Material (contact parts): Earthing clamp: As per customer request Current rail contact: Electrolytic copper Earthing cable: Copper lead, PVC-insulated Frame: Synthetic tube, glassfibre-reinforced Underground railway systems Earthing rack A [mm] B [mm] C [mm] Type Number x150 min. 328 / max C A B 42

43 Clamps for Current Rails Picture shows Usage: ARCUS current rail clamps are suitable for a number of current rail profiles, on the railtrack of underground train systems up to 1 kv. The construction of current rail clamps enables piercing of foreign layers on the rail foot or rail head, especially aluminium oxide, or helps to partially remove foreign layers, in order to obtain an optimum mechanic and electric contact. Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Installation: Clamp is installed by means of fullyinsulated handle. Picture shows Picture shows Underground railway systems Picture shows Current rail clamps Rail profile Connection bolt Type Number DIN Form A 5100 M Underground Railtrack Docklands (London) M Rail foot width max. 85 mm M

44 Earthing System with Earthing Cable and Clamps Usage: To earth and short-circuit current and running rail. Carrying bags, cases and wall holders, see page 34 and following. Type No.: Underground railway systems Device suitable for: Current rail: DIN A5100 Running rail: S 49, S 54, S 64, UIC 60 Parts of device: Current rail clamp: Type No (page 43) Earthing and short-circuiting cable: 95 mm², 1100 mm long, made of highly flexible copper with transparent coating Rail foot earthing clamp: Type No page 14 Other cable lengths are available upon request. Current rail Running rail 44

45 Feeding Rod for Traction Current Usage: As all means of urban public transport, also tram vehicles have to be maintained, repaired or examined. Usually this happens in closed workshop halls, where all necessary work can be carried out independently from weather, under optimum conditions. In these workshops, tram vehicles can be inspected and maintained from all sides, also from underneath and on the top side. Some halls are also equipped with heavy-duty roof cranes, in order to lift complete tram vehicles. For safety reasons, in many cases it is impossible to install the contact wire for power supply in the entire workshop. Either the contact wire ends a few metres in front of the hall, or it continues for a short distance into the hall and ends there. Without contact wire it is neither possible to manouvre tram vehicles inside the hall, nor to test certain electric functions. One possible solution for this problem is to manouvre tram vehicles with haulers inside the hall, and to secure power supply for tests of certain functions by means of a power feeding conductor which is connected to the vehicle. ARCUS has developed a system in cooperation with a number of transport companies. It provides the tram vehicle with power through its pantograph, in order to manouvre and test the tram inside the workshop hall. Tram Further information can be found in our Technical Information Feeder Rod for Tram Vehicle Power Supply. 45

46 Feeding Rod for Traction Current Picture shows Picture shows Picture shows X 2 2 detail Y detail X Y Tram Components 1) Microswitch - secures possibility of power supply to pantograph only after the feeder rod for traction current was safely connected to the pantograph of the tram vehicle. 2) Universal clamp - construction of clamp jaws enables removal of foreign layers (soiling, corrosion) from panthograph 3) Catch strip - helps to connect the universal clamp 4) Rod top part and rod lower part - insulating epoxy-resin tubes 5) Power feeder conductor - feeds the required operating current 6) Hand protection disc 7) Push-button switch - custom-built 8) Handgrip - by turning hand grip the universal clamp closes or opens (2) 9) Control cable - connects safety equipment in maintenance areas (prevention of faulty operations) Feeding rod for traction current Type Number Microswitch Item 1 Universal clamp Item 2 Catch strip Item 3 Rod top part/ rod lower part Item 4 Power feeder conductor Item 5 Hand protection disc Item 6 Push-button switch Item 7 Handgrip Item 8 Control cable Item

47

48 Phone General +49 (0) 89 / Fax General +49 (0) 89 / Fax General +49 (0) 89 / Internet info@arcus-schiffmann.com Seat of the Company Truderinger Str. 199 D Munich Layout: Marion Renz Edition: Subject to change without notice Copyright ARCUS Schiffmann

Product Catalogue. SAFETY EQUIPMENT for Railway Systems

Product Catalogue. SAFETY EQUIPMENT for Railway Systems Product Catalogue SAFETY EQUIPMENT for Railway Systems 8 Your Partner for Safety Equipment Since 1928 the name ARCUS equals quality and reliability in cable connections and safety products. The ARCUS ELEKTROTECHNIK

More information

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device TECHNICAL INFORMATION Dipl.-Ing. (FH) Christian Niklis Stationary Lance Earthing Device GENERAL Lance earthing devices - What s s the use of them? Short-circuit-proof earthing in high voltage substations

More information

SAFETY EQUIPMENT FOR RAILWAYS

SAFETY EQUIPMENT FOR RAILWAYS SAFETY EQUIPMENT FOR RAILWAYS Safety Equipment for Railways Our product range of safety equipment for railways is listed separately in Publication No. DS 501/E. The devices shown are compatible to systems

More information

CONTENTS DEVICES AND EQUIPMENT FOR RAILWAY EARTHING GENERAL INFORMATION SAFETY EQUIPMENT. DEVICES FOR CABLE INSTALLATIONS UP TO 1 kv

CONTENTS DEVICES AND EQUIPMENT FOR RAILWAY EARTHING GENERAL INFORMATION SAFETY EQUIPMENT. DEVICES FOR CABLE INSTALLATIONS UP TO 1 kv CONTENTS GENERAL INFORMATION PAGE Contents 1 Register of type numbers 2 Sales programme 3 General notes, delivery conditions 6 Technical explanations Earthing and Short Circuiting Devices* 7-15 DEVICES

More information

COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS. English. Overhead Conductor Rail. Made in Germany

COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS. English. Overhead Conductor Rail. Made in Germany COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS English Overhead Conductor Rail Made in Germany 2 3 OVERHEAD CONDUCTOR RAILS BY RAIL POWER SYSTEMS THE SOLUTION FOR TIGHT SPOTS Offering significantly lower

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

EDITION 2011/2012 SAFETY EQUIPMENT

EDITION 2011/2012 SAFETY EQUIPMENT EDITION 2011/2012 SAFETY EQUIPMENT Product catalogue The Standard in Matters of Safety. PFISTERER. When work is to be carried out on electrical installations, the safety of personnel, materials and system

More information

Sicat SR. Features. Overhead conductor rail system for mass transit and main-line railways. siemens.com/rail-electrification

Sicat SR. Features. Overhead conductor rail system for mass transit and main-line railways. siemens.com/rail-electrification Sicat SR Overhead conductor rail system for mass transit and main-line railways siemens.com/rail-electrification Urban mass transit systems, such as metros and city trains, and even main-line railways

More information

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS HV EARTHING AND SHORT CIRCUIT LANCE DEVICE For use on maintenance operation and reparation of system parts electrically insulated of interconnection station of hv with air insulation: on coloumn support

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003 Amphenol eries SJT Series SJT VG 96912, Series 1 PAN 6433-2 JN 1003 Ordering information Ordering example: SJT G 06 RT 14-35 P A 014 Series (p. 9, 15, 18) SJT Scoop proof (100% scoop-proof) Junior (Miniature

More information

Compressed Air and Electric Supply System Program C40

Compressed Air and Electric Supply System Program C40 Compressed Air and Electric Supply System Program C40 Table of Contents Overview 4 Product Description...4 System Overview....4 Rail Components 5 General Information...5 Load Diagram....5 Rail Couplers....6

More information

SECURELY HELD. OKW ACCESSORIES are designed to be practical, thus providing you with more flexibility for your individual case.

SECURELY HELD. OKW ACCESSORIES are designed to be practical, thus providing you with more flexibility for your individual case. SECURELY HELD RATIONAL HINGE AND LOCKING TECHNIQUES For easy opening of the devices. THE PRODUCT WALL / RAIL OKW offers you a comprehensive range of. Adapted to the application, our standard cases can

More information

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz III Nominal voltages up to 30 kv / 50 Hz EN/IEC 61243-1 (DIN VDE 0682 411) Also for use in wet weather for indoor and outdoor installations With self-testing device Visual indicator Wide nominal voltage

More information

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01 SECTION H EARTHING ABC Earthing Kits H01 ABC Earthing Kit 4 legged ABC earth kit. Each leg of the earth truss terminates with a female bayonet type pipe connector with a protective rubber hand guard. These

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

Neutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification

Neutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification Neutral section Sicat 8WL5545-4D/4F for overhead contact line systems siemens.com/rail-electrification When installed in pairs, the type Sicat 8WL5545-4D/4F neutral sections serve as phase separation section

More information

Disconnectors and earthing switches up to 25 kv AC

Disconnectors and earthing switches up to 25 kv AC Disconnectors and earthing switches up to 25 kv AC Sicat 8WL6144 for overhead contact line systems in main-line railways siemens.com/rail-electrification The disconnectors and earthing switches of the

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters Surge arresters for railway applications Product guide HP-AR 41 Siemens 2017 siemens.com/arresters Siemens surge arresters for railway applications reliable, stable and safe over protection electrification.

More information

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured A-M COPPER TUBE CRIMPING LUGS for copper conductors A-M series lugs are manufactured from electrolytic copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

Railway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP

Railway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP Competent Solutions for Electric Railways and Tramways THE PFISTERER GROUP the power connection Solutions for Today s and Future Challenges Reliable and maintenance-free infrastructure provides the basis

More information

Electrical connection systems

Electrical connection systems 1 Electrical connection systems Copper tubular cable lugs and connectors 10 Tubular cable lugs 10 Tubular cable lugs for switchgear connections 16 Angle tubular cable lugs 17 Connectors 21 Insulated tubular

More information

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47. Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

CONNECTORS AND FITTINGS

CONNECTORS AND FITTINGS Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.

More information

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application

More information

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany Company main topic [ Product ] TracFeed STR English Section Insulators Made in Germany 2 TracFeed STR section insulator For catenary systems of mainline and mass transit railroads For decades, Rail Power

More information

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 L Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 Aluminium roller shutters ROLL-TO 50 Roller door plastic panel POLAR PLUS Roller door wooden panel ARBOR PLUS Roller door aluminium

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

Around the cable. Socket sleeves.... convincing solutions

Around the cable. Socket sleeves.... convincing solutions Around the cable Socket sleeves... convincing solutions Socket sleeves (male and female) Socket sleeves (female) with cable stop bare brass not insulated, to DIN 46247/part 1-3 and similar Art. no. CSS

More information

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2 3 ELECTRIC TRACTION SYSTEMS 2 3.1. SAFE FOR PEOPLE 2 3.1.1. Electric Traction System 2 3.1.2. Protection against unwanted access 2 3.1.3. Fencing 2 3.1.4. On bridges and other structures 2 3.1.5. At level

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

PFISTERER RAIL SYSTEMS. Components and Systems for the Electrification of Railway Lines.

PFISTERER RAIL SYSTEMS. Components and Systems for the Electrification of Railway Lines. Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Electrification of Rail PFISTERER RAIL SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

KD1E Range Potential Indicators

KD1E Range Potential Indicators KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Limited Warranty & Limitation

More information

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Type overview FSR with guide cables or rods Type key FSR P S 0 0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Cover panel without back-fold: S = small,

More information

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings Insulation Piercing Connectors Dulmison, through its partnership with Michaud in France, provide a comprehensive range of Insulation Piercing Connectors - IPC's. Michaud's dedication to product quality

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

SERIES TAP-CHANGER

SERIES TAP-CHANGER SERIES 090 - TAP-CHANGER Main characteristics This is an off-circuit tap changer. It means DO NOT OPERATE WHILE THE TRANSFORMER IS ENERGISED. Main characteristics of this tap-changer series are: dimensional

More information

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems Befestigungssysteme Klimatechnisches Zubehör Fixing systems With us, insulation work becomes enjoyable For almost three decades, we have been a leading enterprise in innovative systems for technical insulation

More information

Innovac SVS/08 - SVS/ kv modular switchgear

Innovac SVS/08 - SVS/ kv modular switchgear Innovac SVS/08 - SVS/ 3.6-4 kv modular switchgear Product Focus Epoxy resin insulated switchgear in sheet steel enclosure with vacuum interrupters Total reliability in switching, metering and distributing

More information

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8 2.1 Stylebox 15 Overview 2_3 2.1.1 Complete Stylebox 15 Kits 2_7 2.1.2 Stylebox 15 Standard Kit 2_8 2.2 Stylebox 15 Smart 2_10 2.2.1 Width 2_11 2.2.2 Height ezel 2_11 2.2.3 Depth 2_11 2.2.4 Top Cover Panel

More information

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79 73 Contents General.................................................................................................. 74 Wedge tension clamp without jumper guide, for aluminium based conductors...........................

More information

Construction and Wiring Guidelines for Ergon Energy Substation Panels

Construction and Wiring Guidelines for Ergon Energy Substation Panels Construction and Wiring Guidelines for Ergon Energy Substation Panels Table of Contents Purpose and Scope... 1 Responsibilities... 1 Definitions, Abbreviations and Acronyms... 1 References... 1 Panel Wiring...

More information

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer bushings, type GOA 250. Installation and maintenance guide Transformer bushings, type GOA 250 Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor

More information

General catalogue ALUCA accessories for your van racking systems

General catalogue ALUCA accessories for your van racking systems General catalogue ALUCA accessories for your van racking systems www.aluca.de Welcome to ALUCA ALUCA manufactures light-weight, strong and safe systems for those who are on the road each day. We offer

More information

Energy Supply Systems

Energy Supply Systems Energy Supply Systems SINGLE POLE INSULATED CONDUCTOR RAIL 815 100 amps KAT0815-0001b-E Conductor rail system in a high bay storage Slip ring with conductor rail system in a stretch-foil packing machine

More information

BUSBAR TRUNKING SYSTEMS a

BUSBAR TRUNKING SYSTEMS a BUSBAR TRUNKING SYSTEMS 25-63 a Contents 4-9 General features Light and Power. The solution that comes from above 4 The enhanced LB PLUS range 6 Simplified installation for increased performance 8 10-12

More information

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

1 Product Description System Layout Safety Instructions Intended Use Installation... 3 Order Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

Cutting Tools Παγγαίου 6, Ν. Φιλοθέη Αμαρουσίου Αθήνα Τηλ: , Fax:

Cutting Tools Παγγαίου 6, Ν. Φιλοθέη Αμαρουσίου Αθήνα Τηλ: , Fax: 21 Cable knife with clappable blade protection with solid blade and insulated blade back for stripping cables made of shock proofed material special blade for cables Description model length blade Cable

More information

CPCS the U.S.A.

CPCS the U.S.A. Clampsticks "AKA" Shotgun Sticks feature a high quality foam filled fiberglass reinforced plastic tube providing maximum insulation and mechanical strength. They are lightweight and easy to handle. Feature

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors Darwinstraat 10 NL 6718 XR Ede The Netherlands Flexible with energy! Phone +31 (0)342 403900 Fax +31 (0)342 403912 email info@akapp.com URL www.akapp.com Pro-Ductor Insulated flat conductor bar for 4,

More information

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR 3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR www.kraus.com www.kraus.com KRAUS RAILWAY TECHNOLOGY PRODUCT LINE Pantograph Switches Trackside Disconnectors Disconnectors & Earthing Switches Pneumatic Interlock

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title High Voltage and 1500 System Earthing References and Definitions Reference Number PDS 02 (RIC Standard: EP 12 00 00 01 SP) Document Control

More information

T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK

T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK 11350 T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK High Quality Product - MADE IN GERMANY Custom-made According to customer-specific requirements The Mobile Workshop can be used

More information

VP RP BP GP HALOGEN FREE INSULATED TERMINALS. P range funnel entry OPERATING TEMPERATURE UP TO 115 C

VP RP BP GP HALOGEN FREE INSULATED TERMINALS. P range funnel entry OPERATING TEMPERATURE UP TO 115 C VP RP P GP HAOGEN FREE INSUATED TERMINAS P range funnel entry OPERATING TEMPERATURE UP TO 115 C The P range of terminals has been designed, to meet the increasing demands for improved safety and reliability

More information

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E 17 DISTRIBUTION OHL FITTINGS 01 Contents General... 3 Insulator pin straight with round thread, according to ÖNORM E4175... 5 Oscillating top clamp for aluminium based conductors... 5 Side tie for aluminium

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

19" front panels. Order Information. Delivery comprises (kit) Order Information. Note Please order assembly part kit separately.

19 front panels. Order Information. Delivery comprises (kit) Order Information. Note Please order assembly part kit separately. Cabinets 19" front panels There are three versions available 19" front panels (handles 2, 3 and 7 can be mounted) 19" blank panels 19" vented front panels 19" front panels The 19" front panels have additional

More information

Mechanical engineering partner

Mechanical engineering partner Mechanical engineering partner Reliable technology that improves productivity The main thing is that everything works well! In mechanical and electrical engineering everything has to work smoothly, be

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

CENTRE FEED UNIT UP TO 4000A. Safety

CENTRE FEED UNIT UP TO 4000A. Safety CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support

More information

General notes. Operating conditions

General notes. Operating conditions 1 General notes Wöhner busbar systems and components are the result of expert development based on many years of experience. They have been exhaustively tested and hold many approvals. The correct selection

More information

TEKNISK RIKTLINJE TR05-10E

TEKNISK RIKTLINJE TR05-10E Notes Change notes Date 1 (A) Revision of standards and new template 09 / 07 2010 2 Template changed.clause. 10.5.1.4 support clamp inserted. Clause 10.5.4.2 creepage text revised. Clause 10.6.7 Dry inserted

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

Working under tension. Personal protection equipment.... convincing solutions

Working under tension. Personal protection equipment.... convincing solutions Working under tension Personal protection equipment... convincing solutions 233 INFO HUPsafteygloves - insulating gloves Recommendation for use and maintenance Insulating gloves are made of natural latex,

More information

Power distribution components

Power distribution components Industrial electronics Power distribution components Reliable, cost-effective, complete R England sv_001.fm Rittal power distribution components Bar centre distance (mm) Number of poles Busbar dimensions

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Hydraulic Cutting Tools

Hydraulic Cutting Tools Hydraulic Cutting Tools 15 HYDRAULIC CUTTING TOOLS New Battery powered CUTTINGTOOLS The new battery operated hydraulic cutting tools are now more ergonomic, faster and more reliable than ever Reliable

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document

More information

Safe Working on Electrical Installations Earthing and Short-Circuiting Devices

Safe Working on Electrical Installations Earthing and Short-Circuiting Devices Safe Working on Electrical Installations Earthing and Short-Circuiting Devices DS191/E/1211 Earthing and short-circuiting devices Save your life during work on electrical installations When working on

More information

Overhead transmission lines Spacers

Overhead transmission lines Spacers = SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AEL, Asset Management Lines OUR REFERENCE TR05-08E DATE 2016-06-09 CONSU12TATIONS TECHNICAL GUIDELINE REVISION 3 APPROVED Overhead transmission

More information

Catalogue: TEH_02H. Hardware for Sliding Doors (Timber)

Catalogue: TEH_02H. Hardware for Sliding Doors (Timber) Catalogue: TEH_02H Hardware for Sliding Doors (Timber) Hardware for Sliding Doors (Timber) Contents Information Introduction HELM Hardware for Timber Sliding Doors HELM Accessories HELM Modular.Concept

More information

Multiconductor Insulated conductor bar

Multiconductor Insulated conductor bar Darwinstraat 10 NL 6718 XR Ede The Netherlands Flexible with energy! Phone +31 (0)342 403900 Fax +31 (0)342 403912 email info@akapp.com URL www.akapp.com Multiconductor Insulated conductor bar AKAPP Multiconductor

More information

INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY RANGE OF ACCESSORIES COMPETENCE CENTRE INDUSTRIAL VACUUMING. Valid from

INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY RANGE OF ACCESSORIES COMPETENCE CENTRE INDUSTRIAL VACUUMING. Valid from INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY Valid from 01.01.2019 COMPETENCE CENTRE INDUSTRIAL VACUUMING 2 3 DEAR CUSTOMER, This catalogue provides you with an essential selection of the

More information

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES As a leading specialist in electrical power supply, FELS is broadening its MOBILIS range with a highly innovative line of singleconductor rails boasting

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

S. K. Industrial Corporation

S. K. Industrial Corporation +91-8048763042 S. K. Industrial Corporation https://www.indiamart.com/skindlcorpn/ We are an ISO 9001 : 2008 certified company. We are manufacturing, exporting and supplying HT and LT transmission line,

More information

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT CATALOGUE Opto-Electronics 2018.1 ILGT 5.4 Opto-Electronics 2018.1 ILGT ILGT ILGT Opto-Electronics 2018.1 5.4 Safety light grid for power operated gates, also secure directly the wing path of vertically

More information

CORRECT HANDLING OF FLEXIBLE ABRASIVES

CORRECT HANDLING OF FLEXIBLE ABRASIVES L E T T H E S P CONTENTS Page III, IV V - VII CORRECT HANDLING OF FLEXIBLE ABRASIVES OTHER ACTIVITIES 2, 3 GRINDING MACHINES AND STANDARD TYPES OF FLEXIBLE ABRASIVES 4, 5 WHEEL LABEL MARKINGS 6, 7 USE

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information