Product Catalogue. SAFETY EQUIPMENT for Railway Systems

Size: px
Start display at page:

Download "Product Catalogue. SAFETY EQUIPMENT for Railway Systems"

Transcription

1 Product Catalogue SAFETY EQUIPMENT for Railway Systems 8

2 Your Partner for Safety Equipment Since 1928 the name ARCUS equals quality and reliability in cable connections and safety products. The ARCUS ELEKTROTECHNIK ALOIS SCHIFFMANN GMBH is a highly specialised industrial enterprise in which high-quality products are designed and produced for the worldwide market. Our product range includes: Connectors and tools for underground cables Overhead line clamps Earthing and short circuiting devices with cables and bars Lance earthing devices for outdoor switchgear up to 80 ka/0.5 s and 63 ka/1 s High voltage detectors for nominal voltages up to 380 kv Detectors and phase comparators for encapsulated switchgear Compression material and compression tools Devices for current tapping and power supply Always in the centre of our activities: Our clients. Our top aim is their complete and long-term satisfaction! Highly qualified and motivated employees in our company in Munich and in our sales offices are the main condition for a successful conversion of customers' requirements. During the long history of our company we have always accepted some complex requirements of our customers as a challenge to be met. Cooperations with our business partners in technical projects which have in many cases resulted in products with exposed position on the world market. Technical know-how and the latest production techniques to insure long-term quality and reliability of our products. Availability by phone: For queries concerning products and delivery time, and to place an order by phone, we are available as follows: +49 (0)89/ Monday - Thursday: 8:00 am-12:00 noon and 12:30 pm-16:00 pm Friday: 8:00 am-12:00 noon Information concerning this catalogue: All rights reserved for copying of any kind. All dimensions and pictures are not binding. We permanently strive to improve products and reserve the right to change design, dimensions or material.

3 Contents General List of Type Numbers 4 Introduction 5 Railways (Catenary Wire) Earthing Components Phase clamps 8 Clamps for contact wires 10 Earthing clamps 12 Rail earthing clamps 14 Earthing and short-circuiting cables 16 Ball point connectors 17 Earthing Rods Telescopic earthing rods 18 Earthing rods with plug-in connections 19 Earthing Systems Earthing systems for contact wires (profile-free devices) 20 Earthing systems for contact wires (non profile-free devices) 22 Earthing system for feeder lines 27 Earthing system for pylons at rail tracks 28 Earthing systems for construction machinery 29 Bridging devices for rails 30 High Voltage Detectors ARCUSDETECT M - High voltage detector for contact wires and feeder lines 31 ARCUSDETECT M - High voltage detector for railway networks 32 ARCUSDETECT M - High voltage detectors for substations 33 Accessories Carrying bags 34 Carrying cases 36 Suspension hooks (for profile-free earthing) 37 Stopper for earthing cable 37 Wall holders 38 Storage systems 39 Underground Railway Systems Earthing Devices for Underground Railway Systems 40 Clamps for Current Rails 42 Earthing System with Earthing Cable and Clamps 43 Tram Feeding Rod for Traction Current 44 3

4 List of Type Numbers Type Number Page Type Number Page Type Number Page General

5 Introduction Dear reader! Work in or at electric railway installations requires a number of safety steps to minimise or eliminate dangers caused by moving rail vehicles or by electric current. Such safety steps are not always carried out by employees of the railway company, but in emergency cases also by fire brigades or other rescue workers. General Special importance is given to the clear marking of working limits, as well as a permanently secured absence of voltage within these working limits. Specially in train stations with unclear criss-crossing of lines, or on open railtrack with a number of lines running in parallel over long distances and influencing each other, securing the working place is essential. Also the subject of visibility has importance as in many cases an earthing device at the same time marks the working limit. Under any circumstance this working limit needs to be clearly visible, not only at daylight, but also at night, in tunnels, or when a number of pylons and lines in the background make recognition of an earthing rod difficult. Frequently work needs to be carried out during train operation hours, in often very short intervalls without trains, so handling of material is rough. Material will be more strained than from similar operations in utility networks, wear is considerable, and at the same time concessions towards reliability are to be excluded. 5

6 Introduction General High voltage detectors which are to be handled with care as a safety-relevant measuring device, have to withstand many downfalls into the stony roadbed. Earthing material which needs to be carried to the working place over long distances may already suffer superficial damages, but these must not compromise its usage. In order to meet these special requirements, railway material in most cases has its own standards. One example among others is the standard for high voltage detectors for catenary wires (contact wire detector), or the fact that for earthing material higher final temperatures in case of a short circuit are admissible. This way cross-sections of copper leads can be restricted, to make an earthing device portable even over longer distances. In the course of many years a multitude of different products for testing absence of voltage, earthing and short-circuiting, potential equation, and for marking working limits were developed in cooperation with German Railway DB, Austrian National Railways ÖBB, Swiss National Railways SBB, Belgian Railway SNCB, and other European rail companies. Before a product may be named railway material, it has to fulfill requirements demanded by the user, and in many cases pass a practical test over several weeks, to finally pass a formal approval procedure by the customer. 6

7 Introduction This catalogue will give you an overview about our programme of safety equipment for railway systems. We have arranged these products in different groups to facilitate identification. All important details are listed in a table and supported by pictures. General In case of uncertainties how to find a product or how to select a suitable one, please contact us. You will find our contact details on the backside of this catalogue. ARCUS Schiffmann offers you not only a vast range of safety equipment for railway systems, but furthermore will be pleased to support you in selecting the suitable products. This service is a matter of course for us! 7

8 Earthing Components Phase clamps ARCUS phase clamps are suitable for connection to round and flat conductors, ball point and T-bolt connectors. All phase clamps are provided with a spindle shaft according to DIN Construction of phase clamps enables removal of foreign layers (soiling, corrosion) from contact areas. Simple and safe clamping to conductor by fastening with screw thread method. Phase Clamp Clamping Range Connection Bolt Lead Cross Section [mm²] DB Material Number Type Number Round Ø 5-35 mm M12 max Round Ø mm M12 max Flat up to 20 mm, round Ø 9-22 mm, T-bolts up to 20 mm max. 120 M12 Ball point connectors up to Ø 25 mm max Further models available upon request.

9 Earthing Components Type Number Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Type Number Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Type Number With test strip to determine absence of voltage Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Test strip: Galvanised steel 9

10 Earthing Components Clamps for contact wires ARCUS clamps for contact wires are suitable for a number of figure-eight wires, round and double contact wires. All clamps for contact wires are provided with a test strip to determine absence of voltage and a catch device for use as installation aid. All clamps for contact wires are provided with a spindle shaft according to DIN Construction of clamps for contact wires enables removal of foreign layers (soiling, corrosion) from contact areas of contact wire. A disc spring package (not in type no ) secures a constant, high and vibration-proof contact force. Simple and safe installation on contact wire by screw thread method. A separate electric connection of the pressure piece secures optimum current tapping from contact wire. Clamps for Contact Wires Contact Wire Connection Bolt Lead Cross Section [mm²] DB Material Number Type Number Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Ri (DIN ); Ø 10.6 up to 13.2 mm M10 max Single and double contact wire SNCB M12 max Further models available upon request.

11 Earthing Components Type Number With rigid bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type Number With elongated (+5 mm) and rigid bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type Number With compact test strip and catch device Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Stainless steel Type Number With elongated and flexible bayonet spindle Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised steel Type Number With rigid bayonet spindle and elongated cross pin Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated Test strip/catch device: Hot-dip galvanised stee Type Number Single and double contact wire SNCB Material (contact parts): Strap: Aluminium alloy, tin-plated Pressure piece: Aluminium alloy, tin-plated Test strip: Stainless steel Catch device: Hot-dip galvanised steel 11

12 Earthing Components Earthing clamps ARCUS earthing clamps are suitable for a multitude of pylon constructions. Clamp bodies are made of high-strength copper alloy or aluminium alloy. All earthing clamps are provided with conical top or serrated surface made of tempered material (except type no ) to cut through foreign layers (soiling, corrosion, varnish). Simple and safe installation by screw thread method. Earthing Clamp Clamping Range Connection Bolt Lead Cross Section [mm²] DB Material Number Type Number Flat up to 24 mm M12 max Flat up to 40 mm M12 max Flat up to 20 mm, round Ø 9-22 mm, T-bolts up to 20 mm max. 120 M12 Ball point connectors up to Ø 25 mm max Further models available upon request.

13 Earthing Components Type Number With hand screw for simple and safe installation, and anti-twist groove on cable lug connection. Material (contact parts): Contact plate: tempered steel, tin-plated Pressure piece: tempered steel, tin-plated Type Number With grooved circular top for optimum piercing through foreign layers. Material (contact parts): Grooved top: Stainless steel Centring tip: Stainless steel Type Number With plastic handle for simple and safe installation, and anti-twist groove on cable lug connection. Material (contact parts): Strap: Copper alloy, tin-plated Pressure piece: Copper alloy, tin-plated 13

14 Earthing Components Rail earthing clamps ARCUS rail earthing clamps are suitable for a number of different rail profiles. Based on the construction of the rail earthing clamps, foreign layers and especially corrosion are pierced or part-removed from rail foot or rail head, so that an optimum mechanic and electric contact is obtained. Simple and safe installation on rails. Rail Foot Earthing Clamp (Profile-Free Earthing) Rail Profile Connection Bolt Lead Cross Section [mm²] DB Material Number Type Number UIC 60 M12 max S 49, S 54, S 64, UIC 60 M12 max SNCB (50 T, UIC 60, A74/UIC 60A, 63 T) M12 max S 49, S 54, S 64, UIC 60 M12 max S 49, S 54, S 64, UIC 60 M12 max Rail Head Earthing Clamp (Non Profile-Free Earthing) Rail Profile SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 Connection M10 (special cable connection) Ball point connector Ø 25 mm Lead Cross Section [mm²] DB Material Number Type Number max max Further models available upon request.

15 Earthing Components Rail foot earthing clamps (profile-free earthing) Type Number With undetachable ratchet for comfortable and safe installation. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type Number With hand screw for simple and safe installation. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type Number With undetachable ratchet for comfortable and safe installation, especially suitable for heavily corroded rails. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type Number With connection to ratchet 1/2 square-end. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Type Number With hand grip, for distance rail to concrete of max. 20 mm. Material (contact parts): Centring tip: Steel, ceramic-plated Pressure piece: Steel, surface coated Rail head earthing clamps (non profile-free earthing) Type Number With hand screw for simple and safe installation. Material (contact parts): Top pressure piece: Copper alloy, tin-plated Bottom pressure piece: laminated fabric with glassfibres Type Number With hand screw for simple and safe installation, with ball point connector Ø 25 mm. Material (contact parts): Top pressure piece: Copper alloy, tin-plated Bottom pressure piece: laminated fabric with glassfibres 15

16 Earthing Components Earthing and short-circuiting cables All earthing cables meet the required tension test values of IEC d1 d2 Earthing cables are made of highly-flexible copper lead with PVC-coating. Transitions from cable lug to lead coating are enclosed by a stabilising, tenacious elastic transparent sleeve. This mechanic kinking protection guarantees a reliable sealing against moisture ingress. Transparency of insulation enables visibility of copper leads up to the copper cable lug barrel, so that damages of strands caused by ageing can be identified early. Carrying bag page 34 and following. Earthing and Short-Circuiting Cables Cable Length [mm] Lead Cross Section [mm²] Palm Hole Red Flags DB Material Number d1 [mm] d2 [mm] Type Number Further models available upon request.

17 Earthing Components Ball point connectors Safe usage on numerous established pylon constructions of electric railways. Ball point connectors made of high-strength copper, tinplated, nuts and washers made of galvanised steel Type Number DB Material Number Earthing bar made of copper with 2 ball point connectors Ø 25 mm, firmly connected to an earthing clamp for ball point connectors Ø 25 mm. This multiple earth connection takes up 2 one-polar short-circuiting cables. Type Number Earthing bar made of copper with 3 ball point connectors Ø 25 mm, firmly connected to an earthing clamp for ball point connectors Ø 25 mm Type Number DB Material Number Ball point connector Ø 25 mm, thread: M16x47 mm Material: Ball point connectors made of high-strength copper, tin-plated, nuts and spring washers made of galvanised steel. Type Number DB Material Number Ball point connector Ø 25 mm, thread: M16x27 mm Type Number DB Material Number Earthing plate with 2 ball point connectors Ø 25 mm Type Number DB Material Number Earthing plate with 1 ball point connector Ø 25 mm Palm hole: Ø 12.5 mm Further models available upon request. 17

18 Earthing Rods Telescopic earthing rods All extendable earthing rods are designed for the requirements of earthing and short-circuiting electric contact wires. They are used to guide one-polar devices to catenaries, feeders, and traction power lines. LT LG Depending on requirements on transport length, these earthing rods are available in 2- or 3-section versions. For better visibility in the track area, some of these earthing rods are provided with red marks on the lower rod part. Coupling heads are suitable to take up phase clamps (page 8) and clamps for contact wires (page 10) which have a spindle shaft to DIN The earthing rods are equipped with telescopic connections. This enables varied usage lengths until stop at full extension. Type nos and are provided with a hand protection disc instead of a black ring. Carrying bags, cases and wall holders, see page 34 and following. Telescopic Earthing Rods LG [mm] LT [mm] Coupling Head N-Parts DB Material Number Type Number Safety bayonet head Safety bayonet head with locking function Safety bayonet head with locking function Aluminium bayonet Aluminium bayonet Safety bayonet head with locking function Safety bayonet head with locking function Safety bayonet head with locking function Further models available upon request.

19 Earthing Rods Earthing rods with plug-in connections LT All earthing rods with plug-in connections are designed for the requirements of earthing and short-circuiting electric contact wires. They are used to guide one-polar devices to catenaries, feeders, and traction power lines. LG Due to short transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Depending on the total length required, these earthing rods consist of 5 or 7 parts. For better visibility in the track area, these earthing rods are provided with red marks on the lower rod part. Compact coupling heads are suitable to take up phase clamps (page 8) and clamps for contact wires (page 10) which have a spindle shaft to DIN These earthing rods are equipped with very robust couplings. Carrying bags, cases and wall holders, see page 34 and following. Plug-In Earthing Rods LG [mm] LT [mm] Bag Coupling Head N-Parts DB Material Number Type Number Safety bayonet head with locking function Safety bayonet head with locking function Safety bayonet head with locking function ) Safety bayonet head with locking function ) with cable decoiler on mid-section Further models available upon request. 19

20 Earthing Systems Earthing systems for contact wires (profile-free devices) Safe usage on numerous established pylon constructions of electric railways. Easy to maintain and repair. Warning flag or other colour markings for clear visibility of device. Carrying bags, cases and wall holders, see page 34 and following. Type Number SBB Number Telescopic earthing rod (3-section) with safety rod head and take-up devices for cable and earthing clamp Total length: 5770 mm; Transport length: 2320 mm Earthing and short-circuiting cable, 50 mm², mm long Clamp for contact wires Type Number (page 10) Earthing clamp Type Number (page 12) Suspension hook and cable guidance for installation on pylon Type Number (page 37) Warning flag for clear visibility of earthing device Device suitable for: Contact wire: Ri (DIN ); Ø mm Earth connection: Flat up to 24 mm 20 Further models available upon request.

21 Earthing Systems Earthing systems for contact wires (profile-free devices) Type Number DB Material Number Earthing and short-circuiting cables with 3 red flags, 50 mm², mm long Type Number (page 16) Clamp for contact wires Type Number (page 10) Rail foot earthing clamp Type Number (page 14) Suspension hook and cable guidance for installation on pylon Type Number (page 37) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type Number DB Material Number Telescopic earthing rod (2-section) with safety rod head Type Number (page 18) Earthing and short-circuiting cables with 3 red flags, 50 mm², mm long Type Number (page 16) Clamp for contact wires Type Number (page 10) Rail foot earthing clamp Type Number (page 14) Suspension hook and cable guidance for installation on pylon Type Number (page 37) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Further models available upon request. 21

22 Earthing Systems Earthing systems for contact wires (non profile-free devices) Safe usage. Easy to maintain and repair. Warning flag or other coloured markings for clear visibility of device. Carrying bags, cases and wall holders, see page 34 and following. Type Number DB Material Number Due to favourable transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Pluggable earthing rod (5-part) with safety rod head and tubular bag Type Number (page 19) Earthing system Type Number (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Earth connection: Flat up to 24 mm 22 Further models available upon request.

23 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type Number x Earthing and short-circuiting cables with 3 red flags, 50 mm², 8500 mm long Type Number (page 16) 2x Clamp for contact wires Type Number (page 10) 2x Rail foot earthing clamp Type Number (page 14) Carrying bag for cables Type Number (page 35) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type Number Earthing and short-circuiting cable with 3 red flags, 50 mm², 8500 mm long Type Number (page 16) Clamp for contact wires Type Number (page 10) Rail foot earthing clamp Type Number (page 14) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Further models available upon request. 23

24 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type Number DB Material Number Telescopic earthing rod (2-section) with safety rod head Type Number (page 18) Earthing system Type Number (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC 60 Type Number Pluggable earthing rod (2-part) with fixed phase clamp similar to Type Number (page 8) and take-up devices for cable and earthing clamp Total length: 4600 mm; Transport length: 2600 mm Earthing and short-circuiting cable, 95 mm², 4600 mm long Earthing and short-circuiting cable, 95 mm², 1500 mm long 2x Rail head earthing clamp Type Number (page 14) Warning flag for clear visibility of earthing device Device suitable for: Conductor: Round Ø mm Rail: SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 24 Further models available upon request.

25 Earthing Systems Earthing systems for contact wires (non profile-free devices) Type Number SBB Number Pluggable earthing rod (2-part) with fixed clamp for contact wire similar to Type Number (page 10) and take-up device for cable and earthing clamp Total length: 4600 mm; Transport length: 2600 mm Earthing and short-circuiting cable, 50 mm², 4600 mm long Earthing and short-circuiting cable, 50 mm², 1500 mm long 2x Rail head earthing clamp Type Number (page 14) Warning flag for clear visibility of earthing device Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: SBB6 (UIC 60), SBB4 (similar to S 54), SBB1, SBB5 Further models available upon request. 25

26 Earthing Systems Earthing systems for contact wires (non profile-free devices) Usage: Due to favourable transport length especially suitable for traction vehicles, technical emergency services, and fire brigades. Carrying bags, cases and wall holders, see page 34 and following. Type Number Telescopic earthing rod (3-section) with safety rod head Type Number (page 18) Earthing system Type Number (page 23) Device suitable for: Contact wire: Ri (DIN ); Ø mm Rail: S 49, S 54, S 64, UIC Further models available upon request.

27 Earthing Systems Earthing system for feeder lines Carrying bags, cases and wall holders, see page 34 and following. Type Number Earthing and short-circuiting cable, 50 mm², 4000 mm long, Type Number (page 16) Phase clamp Type Number (page 8) Earthing clamp Type Number (page 12) Device suitable for: Conductor: Ø 6-35 mm Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm Further models available upon request. 27

28 Earthing Systems Earthing system for pylons at rail tracks Usage: Earthing device for pylons at rail tracks (potential equalisation). Carrying bags, cases and wall holders, see page 34 and following. Type Number Earthing and short-circuiting cable, 50 mm², 4000 mm long Type Number Rail foot earthing clamp Type Number (page 14) Earthing clamp Type Number (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm 28 Further models available upon request.

29 Earthing Systems Earthing systems for construction machinery Usage: Protective earth for construction machinery. Carrying bag page 34 and following. Type Number DB Material Number Earthing and short-circuiting cable, 50 mm², mm long Type Number (page 16) Rail foot earthing clamp Type Number (page 14) Earthing clamp Type Number (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm Type Number Earthing and short-circuiting cable, 50 mm², mm long Type Number (page 16) Rail foot earthing clamp Type Number (page 14) Earthing clamp Type Number (page 12) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Earth connection: Ball point connector Ø 25 mm T-bolt up to 20 mm Flat up to 20 mm Round Ø 9-22 mm Further models available upon request. 29

30 Bridging Devices for Rails Picture shows Usage: Earthing device for bridging running rails (potential equalisation). Type Number Earthing and short-circuiting cable, 95 mm², 1600 mm long 2x Rail foot earthing clamp Type Number (page 14) Carrying bags, cases and wall holders, see page 34 and following. Type Number Earthing and short-circuiting cable, 95 mm², mm long 2x Rail foot earthing clamp Type Number (page 14) Device suitable for: Rail: S 49, S 54, S 64, UIC 60 Device suitable for: Rail: S 49, S 54, S 64, UIC Further models available upon request.

31 ARCUSDETECT M - High Voltage Detector for Contact Wires and Feeder Lines According to VDE 0681 partp 6 Usage: This high voltage live line detector tests absence of voltage on catenaries with single-phase a.c. of Un=15 kv and nominal frequency of 16.7 Hz. Suitable for outdoor use. Audible and visual indication Self-test including test electrode Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% LG LH LI LV Carrying bag included Type Overview DB Material Number ( ) DB Material Number ( ) U n [kv] f [Hz] Net system LG [mm] LV [mm] effectively single-side isolated 1-phase system LI [mm] LH [mm] Transport Length [mm] N-Parts Bag Type Number 15 16, , Further information can be found in our Technical Information Capacitive Voltage Detectors and Voltage Detections Systems. 31

32 ARCUSDETECT M - High Voltage Detector for Railway Networks Basically to IEC (frequency 16.7 Hz) (and following DIN VDE V ) Usage: This high voltage live line detector tests absence of voltage on railway networks with singlephase a.c. of Un=15 kv and nominal frequency of 16.7 Hz. Suitable for outdoor use. Visual indication Self-test including test electrode Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% Threaded fork contact for overhead lines Transport eye for carabiner LO LH Li Ai Carrying bags, cases and wall holders, see page 34 and following. Type Overview DB Material Number U n [kv] f [Hz] Net system LO [mm] Ai [mm] Li [mm] LH [mm] Transport Length [mm] N-Parts Bag (1) Type Number 15 16, ) not included in the delivery effectively single-side isolated 1-phase system 32 Further information can be found in our Technical Information Capacitive Voltage Detectors and Voltage Detections Systems.

33 ARCUSDETECT M - High Voltage Detectors for Substations Basically to IEC (frequency 16.7 Hz) (and following DIN VDE V ) Usage: This high voltage live line detector tests absence of voltage in substations with nominal frequency of 16.7 Hz. Suitable for outdoor use. Audible and visual indication Self-test including test electrode Simple battery change Temperature range: -25 C up to +50 C Humidity: 20-96% LO LH Li Ai Carrying bags, cases and wall holders, see page 34 and following. Type Overview U n [kv] f [Hz] Net system Single voltage detectors LO [mm] Ai [mm] Li [mm] LH [mm] Transport Length [mm] N-Parts Bag (1) Type Number 15 16, , Voltage range detectors 10, , , ) not included in the delivery effectively single-side isolated 1-phase system Further information can be found in our Technical Information Capacitive Voltage Detectors and Voltage Detections Systems. 33

34 Accessories Carrying bags Tubular bags Design: Polyester, royal blue 2x belt strap black 1 shoulder strap Lid with zipper Inside with transparent pocket for instruction for use Dimensions [mm] Type Number Ø 150x820 long Ø 150x1020 long Ø 150x1100 long Ø 150x1220 long Ø 150x1320 long Ø 150x1420 long Ø 150x1520 long Ø 150x1620 long Ø 150x1720 long Tubular bags Design: Cotton cloth, olive coloured Anti-fouling, water-repellent 2x belt strap black 1 shoulder strap String closure Dimensions [mm] Type Number Ø 200x1800 long Ø 200x2200 long Ø 200x2400 long Further models available upon request.

35 Accessories Carrying bags Carrying bag Design: Tarpaulin, royal blue 1x belt strap black With belt closure Inside with transparent pocket for instruction for use Suitable for 2-part high voltage detectors H [mm] L [mm] Pockets Type Number Type Number Carrying bag for earthing cables Design: Tarpaulin, royal blue 2x belt strap black With zipper Inside with transparent pocket for instruction for use Dimensions [mm]: WxDxH: 420x120x Wrapping bag Design: Tarpaulin 1x belt strap black With belt closure Inside with transparent pocket for instruction for use H [mm] L [mm] Pockets Colour Type Number grey royal blue royal blue royal blue Further models available upon request. 35

36 Accessories Carrying cases Carrying case for high voltage detectors Basic version: Shell of plastic material with foamed inlay Outside Dimensions H [mm] W [mm] D [mm] Type Number Carrying case for high voltage detectors Robust model: Shell of rigid plastic material with aluminium frame and foamed inlays Outside Dimensions H [mm] W [mm] D [mm] Type Number

37 Accessories Suspension hooks (for profile-free earthing) Type Number For profile-free earthing of catenaries, a suspension hook is required. This way the earthing and short-circuiting cable is fixed at the pylon at a distance from the railtrack (see page 21). Type Number For profile-free earthing of catenaries, a suspension hook is required. This way the earthing rod is fixed at the pylon at a distance from the railtrack (see page 20). Stopper for earthing cable Type Number Suitable to stop suspension hook Type Number on profile-free earthing devices (e.g. Type Number and on page 21) The stopper can be mounted easily and fast. 37

38 Accessories Wall holders For storage of high voltage detectors, operating rods and earthing rods Easy and fast installation with 2 screws. Wall holders are made of very strong plastic material. Type Number For insulating rods with tube diameter Ø mm Type Number For insulating rods with tube diameter Ø mm Type Number For insulating rods with tube diameter Ø mm 38

39 Accessories Storage systems Storage brackets help to prevent material damage during storage of earthing and shortcircuiting device and earthing rods. To protect the highly flexible earthing cables, the contact areas of the bracket are rounded. Storage brackets are available in two sizes, and alternatively in plastic or sheet steel material. A clip made of spring steel takes up one earthing rod (for outside tube diameters of Ø mm). H W D 50 Bracket with clip for earthing rod H [mm] W [mm] D [mm] Material Maximum Load [kg] Type Number plastic steel, plastic-coated Bracket only (no clip) H [mm] W [mm] D [mm] Material Maximum Load [kg] Type Number plastic steel, plastic-coated

40 Earthing Devices for Underground Railway Systems Construction with current rail contact from bottom side Usage: These ARCUS short circuiting devices are suitable for earthing and short circuiting underground railtracks with voltages up to 1 kv. These devices are kept in trains, stored in train stations, but can also be found in fire brigade vehicles. Underground railway systems construction with current rail contact from top side Materials for construction with current rail contact from bottom side: Running rail contact: Aluminium alloy Current rail contact: Electrolytic copper Earthing cable: Copper lead, PVC-insulated Tension spring storage: Galvanised steel Jointing and fixing parts: Galvanised steel Frame: Synthetic tube, glassfibre-reinforced Materials for construction with current rail contact from top side: Running rail contact: Electrolytic copper Current rail contact: Electrolytic copper Earthing cable: Copper lead, PVC-insulated Tension spring storage: Galvanised steel Jointing and fixing parts: Galvanised steel Frame: Plates made of polyamide Standardizer - eigene Arbeit own work. CC BY-SA 3.0 Further information can be found in our Technical Information Short-Circuiting Device for Underground Railways. 40

41 Earthing Devices for Underground Railway Systems Construction for power supply from top side Construction for power supply from bottom side C B C Type A B Type B Selection of Types: Design B [mm] C [mm] Railtrack System Type Number Typ A Berlin, Germany Typ A Rotem, Korea Typ A Athen, Greece Typ B Hamburg, Germany Typ B Hamburg, Germany Typ B Rotterdam, the Netherlands Typ B Berlin, Germany Typ B Taipei, Taiwan Typ B Munich, Germany Typ B Munich, Germany Typ B Vienna, Austria Typ B Brussels, Belgium Typ B Prague, Czech Republic Typ B Amsterdam, the Netherlands Typ B Singapore Typ B Helsinki, Finland Typ B Mailand, Italy Typ B Rotem, Korea Typ B Bangkok, Thailand Typ B Berlin, Germany Typ B Bangalore, India Underground railway systems Further information can be found in our Technical Information Short-Circuiting Device for Underground Railways. 41

42 Clamps for Current Rails Usage: ARCUS current rail clamps are suitable for a number of current rail profiles, on the railtrack of underground train systems up to 1kV. The construction of current rail clamps enables piercing of foreign layers on the rail foot or rail head, especially aluminium oxide, or helps to partially remove foreign layers, in order to obtain an optimum mechanic and electric contact. Underground railway systems Material (contact parts): Strap: Aluminium alloy Pressure piece: Aluminium alloy Installation: Clamp is installed by means of fullyinsulated handle Current Rail Clamps Rail Profile Connection Bolt Type Number DIN Form A 5100 M Underground Railtrack Docklands (London) M Rail foot width max. 85 mm M Suburban Train Systems, Berlin M Further models available upon request.

43 Earthing System with Earthing Cable and Clamps Usage: To earth and short-circuit current and running rail. Carrying bags, cases and wall holders, see page 34 and following. Current rail Running rail Underground railway systems Type Number: Device suitable for: Current rail: DIN A5100 Running rail: S 49, S 54, S 64, UIC 60 Parts of device: Current rail clamp: Type Number (page 43) Earthing and short-circuiting cable: 95 mm², 1100 mm long, made of highly flexible copper with transparent coating Rail foot earthing clamp: Type Number page 14 Type Number: Device suitable for: Current rail and running rail: Suburban Train Systems, Berlin Parts of device: Current rail clamp: Type Number (page 42) Earthing and short-circuiting cable: 95 mm², 2000 mm long, made of highly flexible copper with transparent coating Rail foot earthing clamp: Type Number page 14 Further models available upon request. 43

44 Feeding Rod for Traction Current Usage: As all means of urban public transport, also tram vehicles have to be maintained, repaired or examined. Usually this happens in closed workshop halls, where all necessary work can be carried out independently from weather, under optimum conditions. In these workshops, tram vehicles can be inspected and maintained from all sides, also from underneath and on the top side. Some halls are also equipped with heavy-duty roof cranes, in order to lift complete tram vehicles. For safety reasons, in many cases it is impossible to install the contact wire for power supply in the entire workshop. Either the contact wire ends a few metres in front of the hall, or it continues for a short distance into the hall and ends there. Without contact wire it is neither possible to manouvre tram vehicles inside the hall, nor to test certain electric functions. One possible solution for this problem is to manouvre tram vehicles with haulers inside the hall, and to secure power supply for tests of certain functions by means of a power feeding conductor which is connected to the vehicle. Tram ARCUS has developed a system in cooperation with a number of transport companies. It provides the tram vehicle with power through its pantograph, in order to manouvre and test the tram inside the workshop hall. 44 Further information can be found in our Technical Information Feeder Rod for Tram Vehicle Power Supply.

45 Feeding Rod for Traction Current X 2 2 detail Y detail X Y Components 1) Microswitch - secures possibility of power supply to pantograph only after the feeder rod for traction current was safely connected to the pantograph of the tram vehicle. 2) Universal clamp - construction of clamp jaws enables removal of foreign layers (soiling, corrosion) from panthograph 3) Catch strip - helps to connect the universal clamp 4) Rod top part and rod lower part - insulating epoxy-resin tubes 5) Power feeder conductor - feeds the required operating current 6) Hand protection disc 7) Push-button switch - custom-built 8) Handgrip - by turning hand grip the universal clamp closes or opens (2) 9) Control cable - connects safety equipment in maintenance areas (prevention of faulty operations) Tram Feeding Rod for Traction Current Microswitch Item 1 Universal clamp Item 2 Catch strip Item 3 Rod top part/ rod lower part Item 4 Power feeder conductor Item 5 Hand protection disc Item 6 Push-button switch Item 7 Handgrip Item 8 Control cable Item 9 Type Number

46

47

48 Catalogues "Safety Equipment" Capacitive Voltage Detectors and Voltage Detection Systems Fully-Insulated and Part-Insulated Earthing and Short Circuiting Devices for Low Voltage Applications Safety Equipment for Railway Systems Phone General +49 (0) 89 / Fax General +49 (0) 89 / Fax Sales Department +49 (0) 89 / Internet info@arcus-schiffmann.com Seat of the Company Truderinger Str. 199 D Munich Layout: Marion Renz Edition: Subject to change without notice Copyright ARCUS Schiffmann

SAFETY EQUIPMENT Safety Equipment for Railway Systems

SAFETY EQUIPMENT Safety Equipment for Railway Systems Product Catalogue SAFETY EQUIPMENT Safety Equipment for Railway Systems Information concerning this catalogue: All rights reserved for copying of any kind. All dimensions and pictures are not binding.

More information

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device TECHNICAL INFORMATION Dipl.-Ing. (FH) Christian Niklis Stationary Lance Earthing Device GENERAL Lance earthing devices - What s s the use of them? Short-circuit-proof earthing in high voltage substations

More information

SAFETY EQUIPMENT FOR RAILWAYS

SAFETY EQUIPMENT FOR RAILWAYS SAFETY EQUIPMENT FOR RAILWAYS Safety Equipment for Railways Our product range of safety equipment for railways is listed separately in Publication No. DS 501/E. The devices shown are compatible to systems

More information

CONTENTS DEVICES AND EQUIPMENT FOR RAILWAY EARTHING GENERAL INFORMATION SAFETY EQUIPMENT. DEVICES FOR CABLE INSTALLATIONS UP TO 1 kv

CONTENTS DEVICES AND EQUIPMENT FOR RAILWAY EARTHING GENERAL INFORMATION SAFETY EQUIPMENT. DEVICES FOR CABLE INSTALLATIONS UP TO 1 kv CONTENTS GENERAL INFORMATION PAGE Contents 1 Register of type numbers 2 Sales programme 3 General notes, delivery conditions 6 Technical explanations Earthing and Short Circuiting Devices* 7-15 DEVICES

More information

EDITION 2011/2012 SAFETY EQUIPMENT

EDITION 2011/2012 SAFETY EQUIPMENT EDITION 2011/2012 SAFETY EQUIPMENT Product catalogue The Standard in Matters of Safety. PFISTERER. When work is to be carried out on electrical installations, the safety of personnel, materials and system

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS. English. Overhead Conductor Rail. Made in Germany

COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS. English. Overhead Conductor Rail. Made in Germany COMPANY MAIN TOPIC [ PRODUCT ] TracFeed OSS English Overhead Conductor Rail Made in Germany 2 3 OVERHEAD CONDUCTOR RAILS BY RAIL POWER SYSTEMS THE SOLUTION FOR TIGHT SPOTS Offering significantly lower

More information

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS HV EARTHING AND SHORT CIRCUIT LANCE DEVICE For use on maintenance operation and reparation of system parts electrically insulated of interconnection station of hv with air insulation: on coloumn support

More information

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47. Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover

More information

Mechanical engineering partner

Mechanical engineering partner Mechanical engineering partner Reliable technology that improves productivity The main thing is that everything works well! In mechanical and electrical engineering everything has to work smoothly, be

More information

Disconnectors and earthing switches up to 25 kv AC

Disconnectors and earthing switches up to 25 kv AC Disconnectors and earthing switches up to 25 kv AC Sicat 8WL6144 for overhead contact line systems in main-line railways siemens.com/rail-electrification The disconnectors and earthing switches of the

More information

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR 3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR www.kraus.com www.kraus.com KRAUS RAILWAY TECHNOLOGY PRODUCT LINE Pantograph Switches Trackside Disconnectors Disconnectors & Earthing Switches Pneumatic Interlock

More information

Railway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP

Railway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP Competent Solutions for Electric Railways and Tramways THE PFISTERER GROUP the power connection Solutions for Today s and Future Challenges Reliable and maintenance-free infrastructure provides the basis

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany Company main topic [ Product ] TracFeed STR English Section Insulators Made in Germany 2 TracFeed STR section insulator For catenary systems of mainline and mass transit railroads For decades, Rail Power

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

SECURELY HELD. OKW ACCESSORIES are designed to be practical, thus providing you with more flexibility for your individual case.

SECURELY HELD. OKW ACCESSORIES are designed to be practical, thus providing you with more flexibility for your individual case. SECURELY HELD RATIONAL HINGE AND LOCKING TECHNIQUES For easy opening of the devices. THE PRODUCT WALL / RAIL OKW offers you a comprehensive range of. Adapted to the application, our standard cases can

More information

Compressed Air and Electric Supply System Program C40

Compressed Air and Electric Supply System Program C40 Compressed Air and Electric Supply System Program C40 Table of Contents Overview 4 Product Description...4 System Overview....4 Rail Components 5 General Information...5 Load Diagram....5 Rail Couplers....6

More information

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz III Nominal voltages up to 30 kv / 50 Hz EN/IEC 61243-1 (DIN VDE 0682 411) Also for use in wet weather for indoor and outdoor installations With self-testing device Visual indicator Wide nominal voltage

More information

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters Surge arresters for railway applications Product guide HP-AR 41 Siemens 2017 siemens.com/arresters Siemens surge arresters for railway applications reliable, stable and safe over protection electrification.

More information

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003 Amphenol eries SJT Series SJT VG 96912, Series 1 PAN 6433-2 JN 1003 Ordering information Ordering example: SJT G 06 RT 14-35 P A 014 Series (p. 9, 15, 18) SJT Scoop proof (100% scoop-proof) Junior (Miniature

More information

Safe Working on Electrical Installations Earthing and Short-Circuiting Devices

Safe Working on Electrical Installations Earthing and Short-Circuiting Devices Safe Working on Electrical Installations Earthing and Short-Circuiting Devices DS191/E/1211 Earthing and short-circuiting devices Save your life during work on electrical installations When working on

More information

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems Befestigungssysteme Klimatechnisches Zubehör Fixing systems With us, insulation work becomes enjoyable For almost three decades, we have been a leading enterprise in innovative systems for technical insulation

More information

Electrical connection systems

Electrical connection systems 1 Electrical connection systems Copper tubular cable lugs and connectors 10 Tubular cable lugs 10 Tubular cable lugs for switchgear connections 16 Angle tubular cable lugs 17 Connectors 21 Insulated tubular

More information

Sicat SR. Features. Overhead conductor rail system for mass transit and main-line railways. siemens.com/rail-electrification

Sicat SR. Features. Overhead conductor rail system for mass transit and main-line railways. siemens.com/rail-electrification Sicat SR Overhead conductor rail system for mass transit and main-line railways siemens.com/rail-electrification Urban mass transit systems, such as metros and city trains, and even main-line railways

More information

PFISTERER RAIL SYSTEMS. Components and Systems for the Electrification of Railway Lines.

PFISTERER RAIL SYSTEMS. Components and Systems for the Electrification of Railway Lines. Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Electrification of Rail PFISTERER RAIL SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title High Voltage and 1500 System Earthing References and Definitions Reference Number PDS 02 (RIC Standard: EP 12 00 00 01 SP) Document Control

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

Elimsan High Voltage Disconnectors

Elimsan High Voltage Disconnectors Elimsan High Voltage Disconnectors Pantograph Type Center-Break Type Double-Break Type Vertical-Break Type Standards IEC 62271-102 IEC 62271-1 Nature is our most distinguished partner YG-EN-12-01 Elimsan

More information

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured A-M COPPER TUBE CRIMPING LUGS for copper conductors A-M series lugs are manufactured from electrolytic copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity

More information

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

Completing the picture

Completing the picture HIGH VoltaGe cable accessories for 72 kv up to 170 kv Completing the picture based on experience is the future nkt cables GmbH nkt was established in 1891 as cable manufacturer. in 1999 nkt a/s denmark

More information

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA

More information

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01

ABC Earthing Kits. ABC Earthing Kit. ABC/Bare Wire LV Earthing System H01 SECTION H EARTHING ABC Earthing Kits H01 ABC Earthing Kit 4 legged ABC earth kit. Each leg of the earth truss terminates with a female bayonet type pipe connector with a protective rubber hand guard. These

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Neutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification

Neutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification Neutral section Sicat 8WL5545-4D/4F for overhead contact line systems siemens.com/rail-electrification When installed in pairs, the type Sicat 8WL5545-4D/4F neutral sections serve as phase separation section

More information

CPCS the U.S.A.

CPCS the U.S.A. Clampsticks "AKA" Shotgun Sticks feature a high quality foam filled fiberglass reinforced plastic tube providing maximum insulation and mechanical strength. They are lightweight and easy to handle. Feature

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH 788 Instructions for Installation, Operation and Maintenance for DRIESCHER - Air - Insulated Medium - Voltage Compact Switchgears for Substations Rated voltage 12 kv and 24 kv Rated current 630 A 24 k

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

Mechanical engineering partner

Mechanical engineering partner Mechanical engineering partner Reliable technology that improves productivity The main thing is that everything works well! In mechanical and electrical engineering everything has to work smoothly, be

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings

Low Voltage ABC Fittings. Insulation Piercing Connectors. Low Voltage ABC Fittings Insulation Piercing Connectors Dulmison, through its partnership with Michaud in France, provide a comprehensive range of Insulation Piercing Connectors - IPC's. Michaud's dedication to product quality

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy. Gas-insulated medium-voltage switchgear For the mining industry Answers for energy. Full power even under extreme conditions Reliable All over the world, the demand for mineral resources is increasing.

More information

Innovac SVS/08 - SVS/ kv modular switchgear

Innovac SVS/08 - SVS/ kv modular switchgear Innovac SVS/08 - SVS/ 3.6-4 kv modular switchgear Product Focus Epoxy resin insulated switchgear in sheet steel enclosure with vacuum interrupters Total reliability in switching, metering and distributing

More information

Gas Insulated Switchgear

Gas Insulated Switchgear Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology

More information

KD1E Range Potential Indicators

KD1E Range Potential Indicators KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Limited Warranty & Limitation

More information

Around the cable. Socket sleeves.... convincing solutions

Around the cable. Socket sleeves.... convincing solutions Around the cable Socket sleeves... convincing solutions Socket sleeves (male and female) Socket sleeves (female) with cable stop bare brass not insulated, to DIN 46247/part 1-3 and similar Art. no. CSS

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 L Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 Aluminium roller shutters ROLL-TO 50 Roller door plastic panel POLAR PLUS Roller door wooden panel ARBOR PLUS Roller door aluminium

More information

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

Energy Supply Systems

Energy Supply Systems Energy Supply Systems SINGLE POLE INSULATED CONDUCTOR RAIL 815 100 amps KAT0815-0001b-E Conductor rail system in a high bay storage Slip ring with conductor rail system in a stretch-foil packing machine

More information

CONNECTORS AND FITTINGS

CONNECTORS AND FITTINGS Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2 3 ELECTRIC TRACTION SYSTEMS 2 3.1. SAFE FOR PEOPLE 2 3.1.1. Electric Traction System 2 3.1.2. Protection against unwanted access 2 3.1.3. Fencing 2 3.1.4. On bridges and other structures 2 3.1.5. At level

More information

General catalogue ALUCA accessories for your van racking systems

General catalogue ALUCA accessories for your van racking systems General catalogue ALUCA accessories for your van racking systems www.aluca.de Welcome to ALUCA ALUCA manufactures light-weight, strong and safe systems for those who are on the road each day. We offer

More information

General notes. Operating conditions

General notes. Operating conditions 1 General notes Wöhner busbar systems and components are the result of expert development based on many years of experience. They have been exhaustively tested and hold many approvals. The correct selection

More information

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions Operating and maintenance instructions /60 /60 for DRIESCHER Outdoor Switch-Disconnectors Type FLa /60 Type FLa /600 Type FLa /60, FLa /60 SA B76 FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

More information

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document

More information

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application

More information

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

31-SDMS-02 REV. 01 SPECIFICATIONS FOR 31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P

More information

Power distribution components

Power distribution components Industrial electronics Power distribution components Reliable, cost-effective, complete R England sv_001.fm Rittal power distribution components Bar centre distance (mm) Number of poles Busbar dimensions

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv

Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Features

More information

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical

More information

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT CATALOGUE Opto-Electronics 2018.1 ILGT 5.4 Opto-Electronics 2018.1 ILGT ILGT ILGT Opto-Electronics 2018.1 5.4 Safety light grid for power operated gates, also secure directly the wing path of vertically

More information

CO P P E R C A B LES A N D C O N N E C TO R S (P TY)

CO P P E R C A B LES A N D C O N N E C TO R S (P TY) CCC Copper Cables & Connectors (Pty) Ltd, established in 1990, specialises in design and manufacture or repair of Water-Cooled Furnace Cables, Air-Cooled Furnace Cables, Water-Cooled Resistance Welding

More information

Benefits, typical uses

Benefits, typical uses R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning

More information

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE SCHALTBAU CONNECTIONS PRE-ASSEMBLED CONNECTORS Schaltbau connectors assembled as set Whether it is for railway vehicles, charging stations of modern li-ion batterypowered

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer bushings, type GOA 250. Installation and maintenance guide Transformer bushings, type GOA 250 Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor

More information

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8 2.1 Stylebox 15 Overview 2_3 2.1.1 Complete Stylebox 15 Kits 2_7 2.1.2 Stylebox 15 Standard Kit 2_8 2.2 Stylebox 15 Smart 2_10 2.2.1 Width 2_11 2.2.2 Height ezel 2_11 2.2.3 Depth 2_11 2.2.4 Top Cover Panel

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv

More information

The SHK manual chain hoist

The SHK manual chain hoist 07. 2014 The SHK manual chain hoist The SHK and SHK+ manual chain hoist The SHK manual chain hoist features a wide spectrum of applications, independent of a power supply. The robust, compact construction

More information

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors Darwinstraat 10 NL 6718 XR Ede The Netherlands Flexible with energy! Phone +31 (0)342 403900 Fax +31 (0)342 403912 email info@akapp.com URL www.akapp.com Pro-Ductor Insulated flat conductor bar for 4,

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79 73 Contents General.................................................................................................. 74 Wedge tension clamp without jumper guide, for aluminium based conductors...........................

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E

DISTRIBUTION OHL FITTINGS. General Insulator pin straight with round thread, according to ÖNORM E 17 DISTRIBUTION OHL FITTINGS 01 Contents General... 3 Insulator pin straight with round thread, according to ÖNORM E4175... 5 Oscillating top clamp for aluminium based conductors... 5 Side tie for aluminium

More information

Status Date Prepared Reviewed Endorsed Approved

Status Date Prepared Reviewed Endorsed Approved Discipline Engineering Standard NSW Category Signalling Title Specification - Solderless Terminals Screw and Spring Clamp Terminal Blocks Reference Number SPS 51 - (RIC Standard: SC 11 14 00 00 SP) Document

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. MV-CONNEX, HV-CONNEX, IXOSIL Terminations, IXOSIL MSA Slip-on Joint Boxes CABLE SYSTEMS Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. Welcome to the CABLE SYSTEMS Centre of Competence.

More information

INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY RANGE OF ACCESSORIES COMPETENCE CENTRE INDUSTRIAL VACUUMING. Valid from

INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY RANGE OF ACCESSORIES COMPETENCE CENTRE INDUSTRIAL VACUUMING. Valid from INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY Valid from 01.01.2019 COMPETENCE CENTRE INDUSTRIAL VACUUMING 2 3 DEAR CUSTOMER, This catalogue provides you with an essential selection of the

More information

Construction and Wiring Guidelines for Ergon Energy Substation Panels

Construction and Wiring Guidelines for Ergon Energy Substation Panels Construction and Wiring Guidelines for Ergon Energy Substation Panels Table of Contents Purpose and Scope... 1 Responsibilities... 1 Definitions, Abbreviations and Acronyms... 1 References... 1 Panel Wiring...

More information

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

1 Product Description System Layout Safety Instructions Intended Use Installation... 3 Order Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4

More information

FireBox T series The evolution of electrical function maintenance

FireBox T series The evolution of electrical function maintenance FireBox T series The evolution electrical function maintenance THINK CONNECTED. Basic principles and meaning electrical function maintenance Function Function maintenance for electrical systems Electrical

More information