Electrical. Chapter. Electrical Plant Bulks General Plant Electrical Bulks Substation Electrical Plant Bulks
|
|
- Helen Powell
- 5 years ago
- Views:
Transcription
1 Chapter 22 Electrical Electrical Plant Bulks General Plant Electrical Bulks Substation Electrical Plant Bulks Schematic of Project Site Transmission Line Hook-Up Wire Sizes US Country Base UK and JP Country Bases Electrical Class/Division NEC IEC
2 22-2 ICARUS Reference ICARUS Corporation, G3
3 Chapter 22: Electrical 22-3 Electrical Plant Bulks Electrical plant bulks are divided into two categories, general and substation plant bulks. A description of each follows. General Electrical Plant Bulks General electrical plant bulks include cables, trays, grounding, lighting and tracing. 1 Electrical cable runs: wire, armored, multi-core ELEC-CABLE Material Selection: ARMOR - Armored multi-core cable W-C - Single wires in conduit, includes conduit W-NC - Single wires in conduit (less conduit) W-TR - Single wires in tray (less tray) M-C - Multi-core in conduit, includes conduit M-NC - Multi-core in conduit (less conduit) M-TR - Multi-core cable in tray (less tray) LARM - Lead covered armored cable Voltage: V at 60 HZ V at 60 HZ V at 60 HZ V at 50 HZ V at 50 HZ at 50 HZ Cable Size: Default: US: single wires in conduit, else multi-core cable in tray without tray. See Wire Sizes later in this chapter. Conduit Material: Default: *GALV* GALV - Galvanized rigid steel conduit EMT - Electrical mechanical tubing AL - Aluminum PVC - PVC plastic conduit PBON - PVC coated rigid steel (plasti-bond) PVCA - PVC coated aluminum FRE - Fiberglass 2 Rigid conduit, galvanized steel, couplings, fittings and seals CONDUIT Material Selection: Default: *GALV* GALV - Galvanized rigid steel conduit EMT - Electrical mechanical tubing AL - Aluminum PVC - PVC plastic conduit PBON - PVC coated rigid steel (plasti-bond) PVCA - PVC coated aluminum FRE - Fiberglass Diameter: Range: INCHES [ MM] Number of Elbows: Default: *0* No. of Fittings: Default: *0* No. of Conduit Seals: Default: *0*
4 22-4 ICARUS Reference Electrical Plant Bulks - General Electrical Plant Bulks continued 3 Electrical cable tray ELEC-TRAY Material Selection: *GALV*, FBRGL, SS, AL No. of 90 DEG bends: *0* : *L*, T, C, B Width: Range: 6-36 INCHES [ MM]; Default: *18* INCHES [*450* MM] 4 Electrical tracing of existing equipment EQPT-TRACE Electrical tracing of equipment; item of equipment and its insulation are assumed specified elsewhere in the project. Heating Cable : Use P series cable for process manten., A or P series cable for ambient control. 3A - 3 W/FT [10 W/M] Chemelex BTV2-CT cable 5A - 5 W/FT [16 W/M] Chemelex BTV2-CT cable 8A - 8 W/FT [26 W/M] Chemelex BTV2-CT cable 10A - 10 W/FT [33 W/M] Chemelex BTV2-CT cable 5P - 5 W/FT [16 W/M] Chemelex XTV2-CT cable 10P - 10 W/FT [33 W/M] Chemelex XTV2-CT cable 15P - 15 W/FT [49 W/M] Chemelex XTV2-CT cable 20P - 20 W/FT [65 W/M] Chemelex XTV2-CT calbe Distance to Panel: If the distance to the panel board is not specified, the system defaults to the value defined for Area Electrical Specifications. Thermostat Control: Default: *E-AMB* E-AMB - Electric tracing/ambient temperature control Single thermostat, control of electrical tracer based upon low ambient temperature specified for General Area Specifications. E-PRO - Electric tracing/process temperature control Multiple thermostated circuits, control of electrical tracer based upon low ambient temperature specified for General Area Specifications. 5 Electrical tracing of existing piping run PIPE-TRACE Electrical tracing of piping; piping is assumed specified elsewhere. This item also provides insulation of the same size, or one size larger than pipe diameter for pipe diameters of 8 INCHES [200 MM] or smaller. Traced Pipe Length: The pipe being traced is not included, but must be specified elsewhere. Traced Pipe Diameter: The pipe being traced is not included, but must be specified elsewhere. Maintenance Temp.: Process temperature to be maintained. Max: 250 DEG F [120 DEG C] over ambient. Thermostat Control: Default: *E-AMB* E-AMB - Electric tracing/ambient temperature control Single thermostat, control of electrical tracer based upon low ambient temperature specified for General Area Specifications. E-PRO - Electric tracing/process temperature control Multiple thermostated circuits, control of electrical tracer based upon low ambient temperature specified for General Area Specifications. Distance to Panel: Distance -pipe to local panel, feeder run to individual tracers determined by system. Length: Total length of tracer segments, default based on pipe length and diameter. ICARUS Corporation, G3
5 Chapter 22: Electrical 22-5 Electrical Plant Bulks - General Electrical Plant Bulks continued 6 Ground grid GRND-GRID A system of buried cable and rods provide a grid work for grounding equipment, buildings and structures. Wire options: AWG (US only): 6, 2, 1/0, 2/0, 4/0; MM2: 16, 35, 50, 70, 95, 120. Default: *2* AWG [*35* MM2] Rod s: *STD*, EL-L, EL-S. Includes direct-buried grid cable brazed to each ground rod. The default rod type, STD, includes manually-driven ¾ INCH x 10 FEET [3.05 METER] copper-clad ground rods with studs, clamps, etc. The electrolytic rod types, EL-L (3 FEET vertical x 10 FEET horizontal [0.91 x 3.05 METER]) and EL-S (straight 10 FEET length [3.05 M]), include pipe with weep holes, electrolytic filling material, special conductive backfill material, and protective cover. If the number of ground rods is not specified, 4 rods are generated for the first FEET [ METER] of grid cable, then 1 rod for each 200 FEET [61 METER] thereafter. For example, a 10 FEET [3.05 METER] length generates 4 rods, a 200 FEET [61 METER] length generates 5, and 1,000 FEET [305 METER] generates 9. Does not include trenching and backfill. Ground Grid diagram and rod types:
6 22-6 ICARUS Reference Electrical Plant Bulks - General Electrical Plant Bulks continued 7 Area lighting: includes poles, lights and cable AREA-LIGHT Flood: W; Default: *400* Other: W; Default: *175* Fixture : Default: Mercury vapor/explosion proof FL1 - Fluorescent - 1 bulb FL2 - Fluorescent - 2 bulbs FL1E - Fluorescent - 1 bulb, explosion proof FL2E - Fluorescent - 1 bulbs, explosion proof MVPE - Mercury vapor/explosion proof MVPV - Mercury vapor/vaportite MVCE - Mercury vapor/ceiling/explosion proof MVCV - Mercury vapor/ceiling vaportite MVF - Mercury vapor/flood SVPE - Sodium vapor/explosion proof SVPV - Sodium vapor/vaportite SVCE - Sodium vapor/ceiling/explosion proof SVCV - Sodium vapor/ceiling/vaportite SVF - Sodium vapor/flood INPE - Incandescent/explosion proof INPV - Incandescent/vaportite INCE - Incandescent/ceiling/explosion proof INCV - Incandescent/ceiling/vaportite MHV - Mercury halide flood Length/Cable Runs: Cable run length from lighting panel. Power per Light: Range: 100-1,000 W. Flood: Default: *400 W*, Min: 400 W; Other: Default: 175 W; Max: 400 W. Number of Poles: Default: *0*. Pole Height: Default: *20* FEET [*6.0* M]. No. Basic Receptacle: Default: *0*. No. Weld Receptacle: Default: *0*. Wiring System: Default: *3 wire system* 2-2 conductor system 3-3 conductor system 4-4 conductor system Wiring Size: Default: US: *12 AWG*, else: 2.5 MM AWG - US only AWG - US only AWG - US only MM2 - other bases MM2 - other bases 4-4 MM2 - other bases Wire Placement: Default: *ABOVE* ABOVE - Above-grade BURIED - Buried Wire : ARMOR - Armored multi-core cable W-C - Single wires in conduit, includes conduit W-NC - Single wires in conduit (less conduit) W-TR - Single wires in tray (less tray) M-C - Multi-core in conduit, includes conduit M-NC - Multi-core in conduit (less conduit) M-TR - Multi-core cable in tray (less tray) Support type: *PENDT*, BRAKT, STAND, POLE. ICARUS Corporation, G3
7 Chapter 22: Electrical 22-7 Electrical Plant Bulks - General Electrical Plant Bulks continued 8 Electrical control cable runs (LV) CTRL-CABLE Material Selection: ARMOR - Armored multi-core cable W-C - Single wires in conduit, includes conduit W-NC - Single wires in conduit (less conduit) W-TR - Single wires in tray (less tray) M-C - Multi-core in conduit, includes conduit M-NC - Multi-core in conduit (less conduit) M-TR - Multi-core cable in tray (less tray) LARM - Lead covered armored cable No. of Conductors: Range: 3-37 Conduit Material: Default: *GALV* GALV - Galvanized rigid steel conduit EMT - Electrical mechanical tubing AL - Aluminum PVC - PVC plastic conduit PBON - PVC coated rigid steel (plasti-bond) PVCA - PVC coated aluminum FRE - Fiberglass Cable Size: *14*, 12, 10 AWG; *1.5*, 2.5, 4.0 MM2. 9 Group of anodes in deep well DEEP-ANODE A group of anodes in a deep well with connecting leads to an adjacent junction box. Capacity: Based on five amps per anode. Depth: Depth should be based on the local soil conditions. The depth is 100 FEET [30 M] plus 7 FEET [2 M] per anode (5 amps per anode). Well Casing Symbol: Default: *NONE* NONE - No well casing CASED - Cased well 10 Individual galvanic anode GALV-ANODE An individual galvanic anode for road crossings, etc. Length/Cable Runs: Default: *40* FEET [*12* M] 11 Group of anodes in shallow surface bed SURF-ANODE A shallow surface anode bed consisting of anodes with underground leads to an adjacent junction box. of Anode: A - Drilled hole, native backfill B - Drilled hole, coke breeze backfill C - Trench, coke breeze backfill D - Trench, native backfill No. Anodes per Bed: *10* Spacing: Anode spacing is the center-to-center distance. Default: *8* FEET [*2.5* M]
8 22-8 ICARUS Reference Electrical Plant Bulks - General Electrical Plant Bulks continued 12 Potential measurement test station POT-TEST Enter number of test stations per location. 13 Transformer/rectifier RECTIFIER 480 V/60 HZ [415 V/50 HZ] 3 phase input D.C. Output: 50 V/50 A or 100 V/100 A Power pole line must be specified separately. Current: Range: A Length/Cable Runs: Default: *500* FEET [*150* M] 14 Solar panel with storage batteries SOLAR-PANL Solar panels, adjacent storage batteries, control center, supporting structure, fencing and cable to a junction box. Length/Cable Runs: Default: *500* FEET [*150* M] 15 Emergency light with battery EMER-LIGHT Provides short-term, local lighting for personnel in case of an electric power failure. Indoor, general-purpose type includes selection of light types, 6V battery, batteryrecharger, power cable with plug for local outlet, and mounting bracket. : HEPS, HEPR, LEPS, LEPR, STDS, STDR Number of bulbs: *1*, 2 16 Underground cable duct CABLE DUCT : *TILE*, ENVEL, CONC, PRCST ICARUS Corporation, G3
9 Chapter 22: Electrical 22-9 Substation Electrical Plant Bulks Substation electrical plant bulks include transformers, breakers, transmission lines and bus. 1 Bus duct BUS-DUCT Continuous Current: Max: 3,000 A Voltage: *600* V at 60 HZ V at 60 HZ V at 60 HZ V at 50 HZ V at 50 HZ V at 50 HZ. Number of Elbows: Default: 1 per 20 FEET [6 M] Termination : *NONE* NONE - No terminations TRANS - Transformer termination only SWGR - Switchgear termination only BOTH - Switchgear and transformer termination 2 Electrical transformer: 1 or 2 tap TRANSFORM Rated load: Range: ,000 KVA : *DRY*, OIL 3 Oil circuit breakers OIL-C-BRKR Rated voltage: Range: KV Continuous Current: Max: 5 KA 4 Disconnect switches DISCNCT-SW Voltage: Range: KV 5 Overhead transmission line: cables, structures, guys, grounds POLE-LINE See Schematic of Project Site Transmission Line Hook-Up, page Wire size: See Wire Sizes later in this chapter. 6 Steel for substation structure SUBSTN-STL
10 22-10 ICARUS Reference Electrical Plant Bulks - Substation Electrical Plant Bulks continued 7 Circuit breakers: main, feeder, tie-breakers BREAKER Continuous Current: Max: 3,000 A Voltage: through the maximum HV. Interrupt Capacity: LV: MVA; MV: MVA; HV: MVA Breaker type: Defualt: *FEED* FEED - Feeder breaker MAIN - Main breaker TIE - Tie breaker : *AIR*, SF6, VAC 8 Motor control center MCC Floor-mounted assemblies of one or more enclosed vertical sections principally containing combination motor control/overload protection units (starters). Range: LV: HP [ KW] MV: HP [ KW] Voltage: LV or MV : *S*, I The MCCs described below are intended for inside use (i.e., are not for outside use local to the motors). They are unaffected by the electrical class/zone specifications covered later in this chapter. The intelligent MCCs provide more sophisticated electronic control and communication to a control center. The cost for upstream items are not included (e.g., supply bus duct/cable; switchgear [feeder breakers, metering, substation disconnect switch, main breaker]; and substation transformer). There are two types of MCC available in the system (see diagram below)- those which supply electric motors driven at low voltage (MCC-LV: COA 733) and those driven at mid-voltage (MCC-MV: COA 744). The MCC-LV may contain starters for motors and as well as circuit breakers for other small electrical loads (LIGHTING TRANS. BRKR- to supply panelboards feeding lights, electric tracing, control center hardware). The MCC-MV contains only starters for motors. The MCC-LV is a 12-NEMA space cabinet; the MCC-MV is a 3-NEMA space cabinet. This item is specified by the HP [KW] rating of the motor being supplied- this permits the system to select an appropriately sized starter (see table below). The resulting cost includes both the cost of the starter as well as the cost for the fraction of the cabinet occupied by the starter. For example, assume that you specify a 20 HP [15 KW] rating- the reported cost for the MCC-LV is the cost of the 3-space starter plus three-twelfths of the whole cost of the cabinet. Specifying four such items would, in effect, completely account for the cost of one 12-space MCC-LV containing four 3-space starters. - Continued - ICARUS Corporation, G3
11 Chapter 22: Electrical Electrical Plant Bulks - Substation Electrical Plant Bulks continued Motor Size Voltage Starter Size (spaces) < = 10 HP [< = 7.5 KW] LV HP [ KW] LV 3 (lighting transformer breaker) HP [ KW] LV HP [ KW] LV HP [ KW] LV HP [ KW] MV ,000 HP [335-3,150 KW] MV 3 Medium Voltage (MV) and Low Voltage (LV) Motor Control Centers (MCC): 9 Switch board SWITCH-BRD Continuous current: A Voltage: KV Interrupt capacity: *25*-40 KA : VCB, VCS1, VCS2, VCS3 10 AC/DC Transformer AC-DC-TRAN Rating: ampere-hours 11 Package transformer with panel PKG-TRANSF Rated load: KVA Primary voltage: V No. of phases: 1 or *3*
12 22-12 ICARUS Reference Electrical Plant Bulks - Substation Electrical Plant Bulks continued 13 Emergency diesel generator EM-PWR-SET Rated power: KVA 14 Uninterrupted power supply UPS Rated load: KVA. : *STD*, MULT. 15 Power factor connection capacitor PF-CORRECT Capacity: KVAR. Voltage: LV, MV. ICARUS Corporation, G3
13 Chapter 22: Electrical Schematic of Project Site Transmission Line Hook-Up* Power from National or Local Power Supply Grid Overhead Transmission Line Steel for Substation Structure Oil Circuit Breaker Power to Main and Unit Substations * not to scale
14 22-14 ICARUS Reference Wire Sizes Wire sizes must be chosen from one of the following tables: US Country Base US Country Base or AWG Wire Units Wire Size Symbols (gauge sizes) LV MV HV / / / (AWG) (KCMIL)... UK and JP Country Bases UK and JP Country Base or MM2 Wire Units Wire Size Symbols (MM2 sizes) LV MV HV (MM2)... ICARUS Corporation, G3
15 Chapter 22: Electrical Electrical Class/Division National Electrical Code (NEC). Electrical Class and Division Symbol Cable Single Core Single Core or or Multi-Core Multi-Core Wire Wire Armored In Tray In Conduit Cable Flammable Gasses or Vapors 11 Highly inflammable gasses and/or + vapors. Hazardous atmospheres exist continuously or can occur during course of normal operation for this area. Explosion-proof. 12 Flammable liquids are handled + + and processed in this area, but they are normally confined. Combustible Dust 21 Dust is suspended in air + continuously or during course of normal operation for this area. 22 Suspension of dust is not likely + + in this area, but deposits of dust can occur and be ignited by sparks. Combustible Fibers or Particles 31 Locations exist in this area in + + which ignitable fibers are handled or used. 32 Locations exist in this area in which + + easily ignitable fibers are stored. General Purpose GP Non-hazardous conditions Indicates cable type consistent with electrical class and division. Indicates cable type inconsistent with electrical class and division.
16 22-16 ICARUS Reference International Electrical Code (IEC). Electrical Zone Cable Single Core Single Core or or Multi-Core Multi-Core Wire Wire Armored In Tray In Conduit Cable 0 Explosive gas/air mixture is constantly + + present or is present for long periods. 1 Explosive gas/air mixture is likely to + + occur under normal operating conditions. 2 Explosive gas/air mixture is unlikely to occur under normal operating conditions. If it does occur, it will be of short duration. GP Non-hazardous conditions Indicates cable type consistent with electrical class and division. Indicates cable type inconsistent with electrical class and division, WARNing message will be issued in the SCAN report. ICARUS Corporation, G3
17 Chapter 22: Electrical 22-17
Generator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationCOMPLETE REVISION December Process Industry Practices Electrical. PIP ELCGL01D Data Sheets for Electrical Design Criteria
COMPLETE REVISION December 2013 Process Industry Practices Electrical PIP D Data Sheets for Electrical Design Criteria PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of
More informationELECTRICAL MATERIAL SUPPLY
ELECTRICAL MATERIAL SUPPLY 2018 Seven Electrical Solutions (SES) Introduction With over 6 years of experience in providing material to Middle East market, SES is full-line supplier and distributor of electrical,
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationNEC 2011 Code Changes
NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection
More informationE R C. R E R C ; ; W T E C
WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation
More information2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference
2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.
More informationPRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)
Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this
More informationSpring Test 10 due 05/11/2013
Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationLIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016
No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSECTION VII METERING INSTALLATIONS
SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationModular integrated transportable substation (MITS)
Technical Data TD027002EN transportable substation (MITS) Contents Description Page Voltage regulation with bypassing........................................................ 2 Mobile MITS application...............................................................
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationTransmission & Distribution Glossary of Electrical Terms
Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More information9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.
Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016
DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all
More informationRESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS
SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated
More informationSpring Test 7 due 05/03/2013
Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous
More informationElectrical Depth. Josh Kreutzberger Lighting/Electrical
Electrical Depth Electrical Introduction The current power distribution system provides the building with power; however, an alternative design solution was analyzed. This analysis was done in order to
More informationSYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.
SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More information(The actual state exam will be closer to 50 questions in 4 hours time) Master Electrician Practice Test
(The actual state exam will be closer to 50 questions in 4 hours time) Master Electrician Practice Test 1. Accessible as applied to wiring methods means capable of being removed or exposed without damaging
More informationSolid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER
Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING
More informationECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motors, Transformers and Distribution Systems
ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motors, Transformers and Distribution Systems Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw
More informationCustomer Substation Manual
Customer Substation Manual Table of Contents Section Page 2 of 81 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation
More informationSALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL
SALEM CITY POWER DEPARTMENT TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1 Changes or Conflicts in Requirements and Guidelines...1.1 Application for Service...1.2
More informationSwitchgear Skid, C1192
CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts
More informationAdvance 27 ANSI 27 kv switchgear
Advance 27 ANSI 27 kv switchgear Table of contents Advance 27...3 AMVAC breaker...4 Instrument transformers...5 Current transformers...5 27 kv voltage transformers...6 Distribution protection and control...7
More informationUniGear. Technical Guide
UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating
More informationSchedules 1 to 4, Lot B: Extension of the Lessos Substation
1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/
More informationKYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS
KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The
More informationElectrical and Power Transmission Installers, Other CIP Task Grid. Secondary Competency Task List. Level 1 Level 2 Level 3
1 100 BASIC SAFETY 101 Demonstrate proper use of personal protective equipment. 5 102 Identify causes of job site accidents. 5 103 Identify job site hazards. 5 104 Working safely with job hazards. 5 105
More informationGENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108
MATCH NE SEE SHEET E. N DH-6 DH-7 DH-9 DH-9 DH-8 DH-6 DH-8 MATCH NE SEE SHEET E. GENERAL NOTES KE PLAN NTS 407 North st Street, Suite 0 (5) 96-050 Fax (5) 96-06 N MATCH NE SEE SHEET E. DH- DH- DH- DH-7
More informationGrounding Systems. Resistance. Resistance Grounding Systems Contents
Resistance Systems.0-1 Resistance Systems Contents Resistance Systems High Resistance System Medium Voltage...............1-1 High Resistance System Low Voltage..................2-1 Specifications See
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationJACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018
JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More informationAIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE
AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly
More informationEH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map
EH2741 Communication and Control in Electric Power Systems Lecture 3 Lars Nordström larsn@ics.kth.se 1 Course map 2 1 Outline 1. Repeating Power System Control 2. Power System Topologies Transmission Grids
More informationwith Vacuum Circuit Breaker HAF
M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................
More informationChapter 6 Generator-Voltage System
Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals
More informationPDI PowerWave 2 Bus System
1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening, low voltage, vertical or horizontal power busway distribution system. System
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationApproved Meter Sockets and Cabinets
Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to
More informationDescriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear
Descriptive bulletin ReliaGear ND ANSI narrow frame metal-clad switchgear Table of contents Introduction...3 Vmax/A breaker...4 Instrument transformers...5 Potential transformers...6 15 kv potential transformers...6
More informationCOMPACT SUBSTATION GUIDE
COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which
More informationElectric Vehicle Charging Station
EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;
More informationSolid Dielectric, Triple Option Reclosers Catalog O-vst14
Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting
More informationHave You Been Grounded Lately
Have You Been Grounded Lately Thurs, Oct. 26, 2017 9:15-10:15 Phil Simmons Author, Electrical Grounding and Bonding Author Cengage Learning Phil Simmons Have You Been Grounded Lately 2017 NEC Changes Relative
More informationTECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV
Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240
More informationHigh Reliability Power System Design
High Reliability Power System Design Buenos Aires, Argentina June 25 & 26, 2009 Keene M. Matsuda, P.E. Regional Electrical Manager Senior Member IEEE IEEE/PES Distinguished Lecturer ke.matsuda@ieee.org
More informationUniversity of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith
University of California, San Diego Cal (IT) 2 Technical Assignment #2 Brian Smith Advisor: Dr. Moeck 31 October 2005 Brian Smith Lighting/Electrical Option University of California, San Diego Cal (IT)
More informationIndianapolis Power & Light Company
Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis
More informationThe vacuum circuit breaker for commercial buildings, industrial plants and utilities
The vacuum circuit breaker for commercial buildings, industrial plants and utilities EasyPact EXE The easy choice for more value 2 EasyPact EXE EasyPact EXE, a medium voltage vacuum circuit breaker optimizing
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationSERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES
SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT SUBMERSIBLE AND VAULT MOUNTED
More informationEPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration. Arindam Maitra IWC Meeting March 28, 2012
EPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration Arindam Maitra IWC Meeting March 28, 2012 Utility Direct Medium Voltage Fast Charger Conventional DC Fast Charger needs a new three-phase
More informationPERMANENT RESIDENTIAL UNDERGROUND SERVICE
CITY OF RICHLAND ENERGY SERVICES DEPARTMENT 505 Swift Boulevard, MS-21 Richland, WA 99352 Telephone (509) 942-7403 Fax (509) 942-7405 PERMANENT RESIDENTIAL UNDERGROUND SERVICE A. INTRODUCTION This guide
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationCOMPACT BUSWAY 40 & 60 AMP HOUSING
40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum
More informationUNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.
UNDERGROUND SERVCE tems to consider f your trenching route has to be dug by hand, or if a cable must be installed under a paved surface, additional charges apply. f your service cable has to be moved later
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More information1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches
1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationSF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)
SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationMotors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB
Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature
More informationWind Power Solutions. Make Energy Renewable and Reliable!
Wind Power Solutions Make Energy Renewable and Reliable! Reliable Thomas & Betts Products for Clean, Green, Thomas & Betts makes all the products that connect and protect a wind farm and its power distribution
More informationFUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1
THE SOUTH AFRICAN INSTITUTE OF ELECTRICAL ENGINEERS FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 OVERVIEW : 1. Introduction to Distribution, Transmission and Generation
More informationEvaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication serves as a guide that represents the consensus of NEMA member companies and is not intended to override the recommendations
More informationData Center Energy Saving using 5kV Distribution System Architecture. 18 Sep 2009
Data Center Energy Saving using 5kV Distribution System Architecture 18 Sep 2009 Power Density Growing www.networkcomputing.com/crash course data center power.php Increasing Demands 1984 Bank of America
More informationMEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear
2018 MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Non-arc-resistant MV ANSI switchgear Agenda Ratings, dimensions and qualifications MV ANSI circuit breakers for Design features Auxiliary compartments Enclosures
More information150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount
150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower - 5-12' -Surface Mount Part #: EPL-APM-150LED-RT Page: 1 Made in the USA The EPL-APM-150LED-RT Telescoping Pole Mounted Explosion
More information