LV & MV Circuit Breakers. LV & MV Circuit Breaker, Contactor & Overload Relay

Size: px
Start display at page:

Download "LV & MV Circuit Breakers. LV & MV Circuit Breaker, Contactor & Overload Relay"

Transcription

1 LV & MV Circuit Breakers LV & MV Circuit Breaker, Contactor & Overload Relay

2 Leader of Technology Hyundai Heavy Industries' state-of-the-art technologies have created circuit breakers and contactors for electrical systems that are genuine masterpieces. Contents 04 Molded Case Circuit Breaker 10 Miniature Series 12 Contactor & Overload Relay 18 Air Circuit Breaker 20 Vacuum Contactor 22 Vacuum Circuit Breaker

3 LV & MV Circuit Breaker, Contactor & Overload Relay HYUNDAI Circuit Breaker is one of the most reliable and sophisticated products, which realizes the optimum design through electric and kinetic analysis

4 LV & MV Circuit Breaker, Contactor & Overload Relay Molded Case Circuit Breaker Optimum design provides easy-to-use customer installation, while offering versatility and high performance to match today's demand for a reliable and cost-effective product, which is easy to maintain. Qualified Standard & Approval Standard IEC NEMA AB-1 KS C8321 Approval ISO 18001, 14001, 9001 CE (Community European / TU.. V Rheinland) DEKRA (KEMA) KS TSE GOST-R CCC KR, ABS, BV, NK, RINA, LR, GL U-Series ADVANCED TECHNOLOGY in size CUSTOMIZED CHARACTERISTIC in range POWERFUL CAPABILITY in specification UAB type UCB type UPB type name UPB : Type 250 : Ampere frame size X : Recognition code for order Line side terminal Rated frequency Utilization category Ampere frame size Main characterisitics Ui : Rated insulation voltage Uimp : Rated impulse withstand voltage Ue : Rated operational voltage Icu : Rated ultimate short-circuit breaking capacity Ics : Rated service short-circuit breaking capacity Suitability of isolation Rated current Standard Trip unit Trip button Approvals and certificates Load side terminal 4 HYUNDAI HEAVY INDUSTRIES

5 MCCB MINIATURE MC ACB VC VCB UAB Type / AF Ampere frame Number of poles Rated current (A) Breaking capacity [Icu] (ka r.m.s.) Trip mechanism & Characteristics Dimensions (mm) AC220V AC240V AC380V AC415V AC440V AC460V AC600V AC660V Hydraulic magnetic Thermal magnetic Fixed Adjustable UAB30C 2, 3 3, 5, 10, 15, 20, / UAB30R 2, 3 5, 10, 15, 20, / UAB50C 2, 3, 4 5, 10, 15, 20, 30, 40, / UAB50R 2, 3, 4 5, 10, 15, 20, 30, 40, / UAB50S 2, 3, 4 15, 16, 20, 25, 30, 32, 40, ) UAB50H 2, 3, 4 15, 16, 20, 25, 30, 32, 40, ) UAB60C 2, 3, 4 5, 10, 15, 20, 30, 40, 50, / UAB60R 2, 3, 4 5, 10, 15, 20, 30, 40, 50, / UAB100C 2, 3, 4 5, 10, 15, 20, 30, 40, 50, 60, 75, / UAB100R 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, ) UAB100S 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, ) Width Height Depth 50/ /75/ /75/ /75/ The breaking capacity highlighted with green and thick type is standard nominal value for each model in this catalogue. 1) Not applicable to 2P breaker. UCB Type / AF Ampere frame Number of poles Rated current (A) Breaking capacity [Icu] (ka r.m.s.) Trip mechanism & Characteristics Dimensions (mm) AC220V AC240V AC380V AC415V AC440V AC460V AC600V AC660V Thermal magnetic Electronic Width Height Depth Fixed Adjustable UCB50R 2, 3, 4 15, 20, 30, 40, / /90/ UCB50H 2, 3, 4 15, 16, 20, 25, 30, 32, 40, UCB50L 2, 3, 4 15, 16, 20, 25, 30, 32, 40, UCB100R 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, / UCB100S 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, / UCB100H 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, UCB100L 2, 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, UCB160H 2, 3, 4 100,125, UCB160L 2, 3, 4 100,125, UCB250R 2, 3, 4 100, 125, 150, 160, 175, 200, 225, / UCB250S 2, 3, 4 100, 125, 150, 160, 175, 200, 225, / UCB250N 2, 3, 4 100, 125, 150, 160, 175, 200, 225, / UCB250H 2, 3, 4 125, 150, 160, 175, 200, 225, UCB250L 2, 3, 4 125, 150, 160, 175, 200, 225, UCB400R 2, 3, 4 250, 300, 320, 350, UCB400S 2, 3, 4 250, 300, 320, 350, UCB400H 2, 3, 4 250, 300, 320, 350, UCB400L 2, 3, 4 250, 300, 320, 350, UCB630R 2, 3, 4 500, UCB630S 2, 3, 4 500, UCB630H 2, 3, 4 500, UCB630L 2, 3, 4 500, UCB800R 2, 3, 4 700, UCB800S 2, 3, 4 700, UCB800H 2, 3, 4 700, UCB800L 2, 3, 4 700, /90/ /90/ /90/ /105/ /105/ /105/ /140/ /210/ /210/ UCB1000S 3, , / UCB1000L 3, , / UCB1250S 3, , / UCB1250L 3, , / UCB1600S , The breaking capacity highlighted with green and thick type is standard nominal value for each model in this catalogue. - 2P breaker has same dimension with 3P breaker, but the middle pole is removed. 5

6 LV & MV Circuit Breaker, Contactor & Overload Relay UPB Type / AF Ampere frame Number of poles Rated current (A) Breaking capacity [Icu] (ka r.m.s.) Trip mechanism & Characteristics Dimensions (mm) AC220V AC240V AC380V AC415V AC440V AC460V AC660V AC690V Thermal magnetic Electronic Width Height Depth Fixed Adjustable UPB100S 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, 125 1) UPB100H 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, 125 1) UPB100L 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, 125 1) UPB100X 3, 4 15, 16, 20, 25, 30, 32, 40, 50, 60, 63, 75, 80, 100, 125 1) UPB160S 3, 4 100, 125, 160 1) UPB160H 3, 4 100, 125, 160 1) UPB160L 3, 4 100, 125, 160 1) UPB160X 3, 4 100, 125, 160 1) UPB250S 3, 4 125, 150, 160, 175, 200, 225, 250 1) UPB250H 3, 4 125, 150, 160, 175, 200, 225, 250 1) UPB250L 3, 4 125, 150, 160, 175, 200, 225, 250 1) UPB250X 3, 4 125, 150, 160, 175, 200, 225, 250 1) UPB400S 3, UPB400H 3, UPB400L 3, UPB400X 3, UPB630S 3, UPB630H 3, UPB630L 3, UPB630X 3, / / / / / The breaking capacity highlighted with green and thick type is standard nominal value for each model in this catalogue. 1) Rated current of electronic types are as followings; UPB100: A UPB160: A UPB250: A Motor Protection / UPB Type AF Ampere frame Number of poles Rated current (A) AC220V AC240V Breaking capacity [Icu] (ka r.m.s.) AC380V AC415V AC440V AC460V AC660V AC690V UPB100H 3 2.5, 3.2, 6.3, 12.5, 20, 32, 50, 63, 80, UPB100L 3 2.5, 3.2, 6.3, 12.5, 20, 32, 50, 63, 80, UPB250H 3 125, 150, 175, 200, UPB250L 3 125, 150, 175, 200, Dimensions (mm) Width Height Depth The breaking capacity highlighted with green and thick type is standard nominal value for each model in this catalogue. Q-Class (for nuclear power plant application) / HBL Type AF Ampere frame Number of poles Rated current (A) Breaking capacity [Icu] (ka r.m.s.) Characteristics Dimensions (mm) AC220V AC380V AC440V AC480V AC660V E1 class Motor Width Height Depth AC240V AC415V AC460V AC500V AC690V protection HBL103U 3 15, 20, 30, 40, 50, 60, 75, HBL103UQ 3 15, 20, 30, 40, 50, 60, 75, HBL103UM 3 2.5, 3.2, 6.3, 12.5, 20, 32, 50, 63, 80, HBL103UMQ 3 2.5, 3.2, 6.3, 12.5, 20, 32, 50, 63, 80, HBL203U 3 125, 150, 175, 200, HBL203UQ 3 125, 150, 175, 200, HBL203UM 3 125, 150, 175, 200, HBL203UMQ 3 125, 150, 175, 200, The breaking capacity highlighted with green and thick type is standard nominal value for each model in this catalogue. 6 HYUNDAI HEAVY INDUSTRIES

7 MCCB MINIATURE MC ACB VC VCB UAB100S UCB250L UPB400X Switch Disconnector / AF Type Ampere frame Number of poles Rated current (A) 50 UCD50H UCD100S Dimensions (mm) Width Height Depth Type UAD Ampere frame 50 Number of poles Rated current (A) UAD50C 3 50 UAD50S 3 50 Dimensions (mm) Width Height Depth UCD100H UAD100R UCD160H UPD100S UCD 250 UCD250S UCD250H UPD 160 UPD160S UPD250S UCD400S UCD630S UCD800S UPD400S UPD630S UCD1000S 3 1, UCD1250S 3 1, UPB Type Handle Trip button Trip (OCR) unit Arc-chamber unit Terminal Mechanism Moving contact device Maximized repulsive-force trip mechanism Fixed contact device - KS Realized certified by twin products. contact English structure nameplate (two contacts and in fixed 50Hz contact marking are not available. - The device, breaking other two capacity in moving highlighted contact device), with green up-down and direction Arc pressure actuator (APA) thick type is standard nominal value for each model in this catalogue. - 2P repulsion breaker at both has sides same of rotary dimension structure, with and 3P u-shaped breaker, terminal but the middle Arc pole pressure is removed. occurred by short-circuit structure of fixed contact. current can be detected through APA and Contribute to increase of main contact travel distance, prevention operates trip mechanism before the of arc re-ignition, and correct lead of arc projection to arc chute. response of trip sensor. Minimizing total breaking time, Maximizing current-limiting performance 7

8 LV & MV Circuit Breaker, Contactor & Overload Relay Accessories Interpole barrier [ TQQ ] Terminal cover [ TCF ] DIN-rail adapter [ DRA ] Cage terminal block [ CTB ] Plug-in mounting base [ TDM ] Auxiliary switch [ AUX ] Trip alarm switch [ ALT ] Shunt trip [ SHT ] Motor operator [ MOT ] Under voltage trip [ UVT ] Surface type operating handle [ TFG ] Cage terminal block [ CTB ] Extended type operating handle [ TFH ] Terminal cover [ TCF ] Interpole barrier [ TQQ ] The applicable accessories of each MCCB are not same as above. For exact application to each MCCB, please reter to product catalogue. 8 HYUNDAI HEAVY INDUSTRIES

9 MCCB MINIATURE MC ACB VC VCB UMB30Ra UMB30Sg UDB100H UMG30Ca UDG100H Miniature Type / AF Type UMB UDB UMG UDG Ampere frame Number of poles Rated current (A) Breaking capacity [Icu] (ka r.m.s.) AC220V AC240V AC380V AC415V AC440V AC460V Dimensions (mm) Width Height Depth UMB30Ra 2 15, 20, UMB30Rb 2 15, 20, UMB30Sg 2 15, 20, UMB30Hg 2 15, 20, UMB50Sg 2 15, 20, 30, 40, UMB50Hg 2 15, 20, 30, 40, UDB30S 2, 3 3, 5, 10, 15, 20, UDB30H 2, 3 5, 10, 15, 20, UDB50S 2, 3 5, 10, 15, 20, 30, 40, UDB50H 2, 3 5, 10, 15, 20, 30, 40, UDB100S 2, 3 15, 20, 30, 40, 50, 60, 75, UDB100H 2, 3 15, 20, 30, 40, 50, 60, 75, / UMG30Ca 2 15, 20, UMG30Cb 2 15, 20, UMG30Ra 2 15, 20, UMG30Rb 2 15, 20, UMG30Cd 2 15, 20, UMG30Rd 2 15, 20, UMG30Sg 2 15, 20, UMG30Hg 2 15, 20, UMG50Sg 2 15, 20, 30, 40, UMG50Hg 2 15, 20, 30, 40, UDG30S 2, 3 3, 5, 10, 15, 20, UDG30H 2, 3 5, 10, 15, 20, UDG50S 2, 3 5, 10, 15, 20, 30, 40, UDG50H 2, 3 5, 10, 15, 20, 30, 40, UDG100S 2, 3 15, 20, 30, 40, 50, 60, 75, UDG100H 2, 3 15, 20, 30, 40, 50, 60, 75, / KS certified products. English nameplate and 50Hz marking are not available. - The breaking capacity highlighted with green and thick type is standard nominal value for each model. 2P breaker has same dimension as 3P breaker, but the middle pole is removed. 9

10 LV & MV Circuit Breaker, Contactor & Overload Relay Miniature Series Miniature Circuit Breaker [ MCB ] Residual Current Circuit Breaker [ RCCB, RCBO ] Miniature Switch Disconnector [ MSD ] Mini Breaker [HBD, HiBC] HYUNDAI Miniature Series are the perfect solution to protect electric overload, short circuit and earth leakage in the household and commercial installations. With consistent and elegant appearances, the Hyundai Miniature Series provide various selection, easy installation, economic benefit and high reliability based on international standard IEC. Qualified Standard & Approval Standard IEC IEC IEC IEC IEC Approval ISO 18001, 14001, 9001 CE DEKRA (KEMA) IRAM BV GOST-R TSE Miniature Circuit Breaker HiBD63-N HiRC63-N HiRO40 HBD51h HiBD125 HiBD63h HiBD63-N HiBD63-NS HiBD63-S HiBD63-E Standard IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN Number of poles (P) Rated current [In] (A) 1, 2, 3, 4, 1+N, 3+N 63, 80, 100, 125 1, 2, 3, 4, 1+N, 3+N 1, 2, 3, 4, 5, 6, 10, 13, 15, 16, 20, 25, 32, 40, 50, 63 1, 2, 3, 4, 1+N, 3+N 1, 2, 3, 4, 5, 6, 10, 13, 15, 16, 20, 25, 32, 40, 50, 63 1+N (1 pole size) 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4, 5, 6, 10, 13, 15, 16, 20, 25, 32, 40, 50, 63 1, 2, 3, 4, 5, 6, 10, 13, 15, 16, 20, 25, 32, 40, 50, 63 Rated insulation voltage [Ui] (V) AC500 AC500 AC500 AC500 AC500 AC500 Rated operational voltage [Ue] (V) AC240/415 1) AC240/415 1) AC240/415 1) AC240 AC240/415 1) AC240/415 1) Rated impulse withstand voltage [Uimp] (kv) Rated conditional short-circuit current (ka) AC220/240V (1-25A), 4.5(32-40A) 6(1-25A), 4.5(32-40A) Rated short-circuit breaking capacity [Icu] (ka r.m.s.) IEC IEC AC380V AC400/460V (1-25A), 4.5(32-40A) 6(1-25A), 4.5(32-40A) AC220/240V AC400/460V Ics (=% Icu) Tripping characteristic (curve) B, C, D B, C, D B, C, D B, C B, C B, C Durability (times) Accessories Electrical 10,000 10,000 10,000 10,000 10,000 10,000 Mechanical 20,000 20,000 20,000 20,000 20,000 20,000 operating frequency per hour Auxiliary switch Trip alarm switch Shunt trip Shunt trip & Auxiliary switch Under voltage trip Pad lock - 1) AC415V is not applicable for 1P and 1P+N breaker. 10 HYUNDAI HEAVY INDUSTRIES

11 MCCB MINIATURE MC ACB VC VCB Miniature Switch Disconnector Mini Breaker HBD51D HBD52D HBD53D HBD51HD HBD52HD HBD53HD Standard IEC IEC Number of poles (P) Rated current (A) 10, 15, 20, 30, 40, 50 10, 15, 20, 30, 40, 50 Rated insulation voltage [Ui] (V) AC460 AC460 Rated operational voltage [Ue] (V) AC240/460 1) AC240/460 1) Rated impulse withstand voltage [Uimp] (kv) 6 6 Rated short-circuit breaking capacity Ultimate [Icu] (ka r.m.s.) 1) AC460V is not applicable for 1P breaker. AC220/240V, 50-60Hz 5 10 DC125V 5 10 Service [Ics] % of [Icu] Terminal connection Screw Screw HBD51 HBD52 HBD53 HBD51h HBD52h HBD53h HiBC32S Standard IEC IEC IEC Number of poles (P) (2PIE) Rated current (A) 10, 15, 20, 30, 40, 50 10, 15, 20, 30, 40, 50 10, 15, 20, 30 Rated insulation voltage [Ui] (V) AC460 AC460 AC500 Rated operational voltage [Ue] (V) AC240/460 1) AC240/460 1) AC220 Rated impulse withstand voltage [Uimp] (kv) Rated short-circuit breaking capacity Ultimate [Icu] (ka r.m.s.) HiSD125 Standard IEC/EN Number of poles (P) 1, 2, 3, 4 Rated current [In] (A) 16, 32, 40, 63, 80, 100, 125 Rated insulation voltage [Ui] (V) AC500 Rated operational voltage [Ue] (V) AC240/415 1) Rated impulse withstand voltage [Uimp] (kv) 6 Durability (times) Electrical 10,000 Mechanical 20,000 Operating frequency per hour 120 1) AC415V is not applicable for 1P breaker. Residual Current Circuit Breaker HiRC100-N HiRC63-N HiRC63 HiRO40 HiRD125 HiRD63 HiRD32 Standard IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN Current characteristic (type) AC, A AC, A AC, A AC AC AC AC Number of poles (P) 2(1+N), 4(3+N) 2(1+N), 4(3+N) 2(1+N), 4(3+N) 1+N 1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4 Rated current [I n] (A) 63, 80, 100 Rated residual current [In] (ma) 30, 100, 300, , 25, 32, 40, 63 30, 100, 300, , 25, 32, 40, 63 30, 100, 300, 500 1, 3, 5, 6, 10, 16, 20, 25, 32, 40 10, 30, 100, 300, , 80, 100, , 50, 63 10, 30, 100, 300, , 30, 100, 300, 500 1, 2, 3, 4, 5, 6, 10, 13, 15, 16, 20, 25, 32 10, 30, 100, 300, 500 Rated insulation voltage [Ui] (V) AC500 AC500 AC500 AC500 AC500 AC500 AC500 Rated operational voltage [Ue] (V) AC240/415 1) AC240/415 1) AC240/415 1) AC240 AC240/415 1) AC240/415 1) AC240/415 1) Rated impulse withstand voltage [Uimp] (kv) Rated conditional short-circuit current (ka) Rated short-circuit breaking capacity AC220/240V IEC AC380V [Icu] (ka r.m.s.) AC400/460V Ics (=% Icu) Tripping characteristic (curve) B, C, D B, C, D B, C, D B, C, D Electrical 10,000 10,000 10,000 10,000 10,000 10,000 10,000 Mechanical 20,000 20,000 20,000 20,000 20,000 20,000 20,000 Durability (times) Operating frequency per hour 120 1) AC415V is not applicable for 2P (1P+N) and 1P+N breaker. 240 (16,25A), 120 (32,40,63A) 240 (16,25A), 120 (32,40,63A) AC220/240V, 50-60Hz DC125V Service [Ics] % of [Icu] Terminal connection Clip & Screw Clip & Screw Screw 11

12 LV & MV Circuit Breaker, Contactor & Overload Relay Contactor & Overload Relay HYUNDAI Contactor & Overload Relay employs a modular design, which allows quick and simple mounting of auxiliary contact blocks, timers, mechanical latching blocks, etc. With highly advanced design for industrial applications such as motor control centers, the HYUNDAI contactor is appropriate for various control systems. It is also favored by shipyards and power plants whose criteria includes high reliability and performance. Qualified Standard & Approval Standard IEC EN UL 508 BS 47794, BS 5424, BS 4941 VDE 0660 DNV KS C4504 JISC 8328, JEM 1038 Approval ISO 18001, 14001, 9001 CE ( Community European / TU.. V Rheinland) KERI KS UL / C-UL TSE GOST-R CCC KR, ABS, BV, NK, LR U-Series Magnetic Contactor UMC9 UMC225 Durability Capacity (IEC 60947, AC-3 [Ie], kw/a) (at AC440V, 1000times) AC200 /240V AC380 / 440V AC500 / 550V AC660 /690V AC1000V Electrical Mechanical UMC9 2.5/9 4/9 4/7 5.5/6-2,500 25,000 UMC12 3.5/12 5.5/12 7.5/12 7.5/9-2,500 25,000 UMC18 4.5/18 7.5/18 8.5/15 7.5/9-2,500 15,000 UMC25 5.5/25 11/25 15/22 15/18-2,500 15,000 UMC32 7.5/32 15/ / /22-2,000 15,000 UMC40 11/ /40 22/32 22/23-2,000 15,000 UMC50 15/50 22/50 30/43 30/28-2,000 15,000 UMC /65 30/65 33/60 33/35-2,000 15,000 UMC75 22/75 37/75 37/64 37/42-2,000 10,000 UMC85 25/85 45/85 50/75 45/45-2,000 10,000 UMC100 30/100 55/100 50/85 45/65-2,000 10,000 UMC115 37/115 60/115 59/100 55/65 65/50 1,000 5,000 UMC130 40/130 65/130 70/120 75/82 75/54 1,000 5,000 UMC150 45/150 75/150 90/140 90/120 90/66 1,000 5,000 UMC185 55/185 90/ / / /78 1,000 5,000 UMC225 75/ / / / /96 1,000 5,000 UMC265 80/ / / / /113 1,000 5,000 UMC300 90/ / / / /141 1,000 5,000 UMC / / / / /178 1,000 5,000 UMC / / / / / ,000 UMC / / / / / ,000 UMC / / / / / ,000 Operation current Auxiliary contact (standard) Dimensions (WxHxD, mm) AC,DC 1NO or 1NC 44x75x80(AC) 44x75x112(DC) AC,DC AC,DC AC,DC 0NO+0NC 0NO+0NC 2NO+1NC (DC only) 0NO+0NC 2NO+1NC (DC only) 45x83x94(AC) 45x83x127(DC) 55x106x111(AC) 79x106x111(DC) 70x140x128(AC) 94x140x128(DC) AC/DC 2NO+2NC 103x155x146 AC/DC 2NO+2NC 138x204x174 AC/DC 2NO+2NC 163x243x203 AC/DC 2NO+2NC 276x314x HYUNDAI HEAVY INDUSTRIES

13 MCCB MINIATURE MC ACB VC VCB Thermal Overload Relay UTH12 UTH32 UTH65 UTH100 UTH150 UTH265 UTH400 UTH800 Rated current (A) Auxiliary contact (standard) NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC Dimensions (WxHxD, mm) 45x79x76 45x81x91 55x94x105 70x108x x159x x185x x205x A: 180x205x A: 245x223x A: 245x223x197 Applied contactor UMC9 UMC12 UMC18 UMC25 UMC32 UMC40 UMC50 UMC65 UMC75 UMC85 UMC100 UMC115 UMC130 UMC150 UMC185 UMC225 UMC265 UMC300 UMC400 UMC500 UMC630 UMC800 Separate mounting block (option) UTHMB12 UTHMB32 UTHMB65 UTHMB

14 LV & MV Circuit Breaker, Contactor & Overload Relay Control Relay Auxiliary contact Operation current UMX04 0NO+4NC UMX13 1NO+3NC UMX22 2NO+2NC AC UMX31 3NO+1NC UMX40 4NO+0NC Auxiliary contact Operation current UMT04 0NO+4NC UMT13 1NO+3NC UMT22 2NO+2NC DC UMT31 3NO+1NC UMT40 4NO+0NC UMX UMT Auxiliary Contact Block Auxiliary contact Applicable product Mounting position UAB02 0NO+2NC UAB11 1NO+1NC UAB20 2NO+0NC UAB04 UAB13 0NO+4NC 1NO+3NC UMC9-100 UMX, UMT Front UAB22 2NO+2NC UAB31 3NO+1NC UAB40 4NO+0NC UAL65 1NO+1NC UMC9-65 UAL100 1NO+1NC UMC Side UAL400A 1NO+1NC UMC Mechanical Interlock Unit Applied contactors UTL65S UMC9-65 UTL100 UMC UTL265 UMC UTL400 UMC Electronic Timer Block Control voltage Applicable product UET1 AC/DC90-240V UMC9-100, UET2 AC/DC24-60V UMX, UMT Mechanical Latching Block Control voltage Applicable product ULB100 AC/DC24 AC/DC48 AC/DC AC/DC AC440 UMC9-100, UMX, UMT Surge Absorber Item Control voltage Applicable product RC-unit URC32 URC100 AC24-48V AC V AC V AC24-48V AC V AC V UMC9-32, UMX UMC Clamping diode UCD100 DC24-125V UMC9-100, UMT 14 HYUNDAI HEAVY INDUSTRIES

15 MCCB MINIATURE MC ACB VC VCB Accessories Contactor UMC Front safety cover Auxiliary contact block (Front mounting) UAB Auxiliary contact block (Side mounting) UAL Mechanical latching block ULB Electronic timer block UET Mechanical interlock unit UTL Surge absorber URC/UCD Thermal overload relay UTH The applicable accessories of each contactor are not same as above. For exact application to each contactor, please refer to product catalogue. Front Safety Cover UMC100IC UMC150IC UMC265IC UMC400IC UMC800IC Applicable product UMC9-100, UMX, UMT UMC UMC UMC UMC Feature Item Moving contacts Main contact UMCTIP Spare Part Fixed contacts Feature Item Coil UMCOL Main terminal cover Coil terminal cover Terminal protection cover UMC_PC Arc chute UMCHT Auxiliary contact terminal cover 15

16 LV & MV Circuit Breaker, Contactor & Overload Relay Hi-Series HiMC 4Pole Magnetic Contactor HiMC 90F HiMC 50F HiMC9F HiMC12F HiMC18F HiMC22F HiMC32F HiMC40F HiMC50F HiMC65F HiMC80F HiMC90F Rated insulation voltage [Ui] V AC750 AC750 AC750 AC750 AC750 AC750 AC750 AC1,000 AC1,000 AC1,000 Rated operation voltage [Ue] V AC690 AC690 AC690 AC690 AC690 AC690 AC690 AC690 AC690 AC690 Rated impulse voltage [Uimp] kv Rated current (AC-1) [Ith] A AC-3 (le) AC-4 (le) AC V 2.2/9 3.5/13 4.5/18 5.5/22 7.5/32 11/40 15/ /70 22/80 25/90 AC V 4/9 5.5/12 7.5/18 11/22 15/ /40 22/50 30/65 37/80 45/90 kw/a AC V 4/7 7.5/12 8.5/15 15/ /28 22/32 30/43 37/60 45/70 50/80 AC V 5.5/6 7.5/9 7.5/9 15/ /22 22/23 25/28 37/35 45/43 50/50 Lifetime Electrical 10, Mechanical times 2,500 2,500 1,500 1,500 1,500 1,500 1,500 1,500 1,000 1,000 AC V 1.5/8 2.2/11 3.7/16 3.7/18 4.5/22 5.5/25 7.5/35 11/50 14/60 16/68 kw/a AC V 2.2/6 4/9 4/11 5.5/13 7.5/17 11/24 15/32 22/47 27/56 32/64 Lifetime Electrical 10,000 times Accessories Auxiliary contact block Mechanical interlock unit Mechanical latching block Surge absorber Electronic timer Item Order code Specification Application Mounting RC Unit HiAB40 IAB 40NS 4NO+0NC HiAB13 IAB 13NS 1NO+3NC HiAB31 IAB 31NS 3NO+1NC HiAB22 IAB 22NS 2NO+2NC HiAB02 IAB 02NS 0NO+2NC HiAB20 IAB 20NS 2NO+0NC HiAB11 IAB 11NS 1NO+1NC HiMC9-50F Front of contactor HiAL11 IAL 11NR 1NO+1NC HiMC9-22F Left of contactor HiAF11 IAF 11NS 1NO+1NC HiMC65-90F Side of contactor HiTL HLB HRC ITL40 ITL50F ITL130 HLB2 F024 HLB2 F110 HLB2 F220 HRC40 Y048 HRC40 Y220 HRC40 Y380 HRC90 Y048 HRC90 Y220 HRC90 Y380 - AC/DC24V AC/DC110V AC/DC220V AC48V AC220V AC380V AC48V AC220V AC380V HiMC9-40F HiMC50F HiMC65-90F HiMC9-50F HiMC9-40F HiMC50-90F Clamping diode HOKYZX HOKYZX38 DC HiMC9-50F HOKZE HOKZE1 HOKZE2 AC/DC90-240V AC/DC24-60V HiMC9-50F Between contactors Front of contactor Coil terminal of contactor Front of contactor 16 HYUNDAI HEAVY INDUSTRIES

17 MCCB MINIATURE MC ACB VC VCB Digital Motor Protection Relay Load Current range Control voltage Type 05, 10 UMP-KOM UMP-KOL Power type Current type K Type P Type C Type R Type 5 Type UMP-KTM UMP-KTL A (0.2-6A with external CT) 07, A VAC (50/60Hz) (90-370VDC) 24VAC (50/60Hz) (24VDC) UMP-POM UMP-POL UMP-PCM UMP-PCL 0.2-5A (available for external CT) A (0.2-5A with external CT) AC85-260V (50/60Hz) (DC90-370VDC) Free voltage 24VAC (50/60Hz) (24VDC) UMP-COM UMP-COL UMP-CTM UMP-CTL UMP-CCM UMP-CCL A (0.2-6A with external CT) 5-70A VAC (50/60Hz) (90-370VDC) 24VAC (50/60Hz) (24VDC) UMP-ROM UMP-ROL UMP-RCM UMP-RCL UMP-5OM UMP-5OL UMP-5TM UMP-5TL 0.2-5A (available for external CT) A (0.2-5A with external CT) UMP-5CM UMP-5CL AC85-260V (50/60Hz) (DC90-370VDC) Free voltage 24VAC (50/60Hz) (24VDC) Available frequency/inverter Hz 1-400Hz Hz 1-400Hz 1-400Hz Single phase (1P) Three phase (3P) Over load Over current Under load Under current Over voltage Under voltage Phase loss/incomming voltage Phase loss/load current Reverse phase/incomming voltage Reverse phase/load current Current unbalance Voltage unbalance Pre-alarm Locked rotor Shock/Stall - - Short circuit Insulation resistance measurement Ground fault Over temperature Temperature Line voltage Insulation resistance Ground fault current Load current Watt hour meter Accumulated working time Preset value check in operation Load factor F-R(Y-D) transfer timer Level alarm FWD-REV operation On-Off s/w button Password Main contactor auto close mA RS RS Modbus Interface with note PC Protection Indication Auxiliary Communication UMP-5SM 17

18 LV & MV Circuit Breaker, Contactor & Overload Relay Air Circuit Breaker Designed for both industrial and marine application, HYUNDAI Air Circuit Breakers have innovated structure, various protection, and reliable performance. Qualified Standard & Approval Standard IEC , 2 EN AS NEMA PUB NO. SG3 ANSI C37.13 VDE 0660 GOST-R GOST-R KS C 4620 Approval ISO 18001, 14001, 9001 CE (Community European / TU.. V Rheinland) KS (KOREA) GOST-R (RUSSIA) CCC (CHINA) KR, GL, LR, ABS, BV, NK, DNV, RINA CB Type Test DEKRA KERI UAN Type UAN and UAS Type Rated current [In] (A, max. at 40 C) UAN UAS Frame A frame B frame C frame A frame B frame 06 : : : 1, : 1, : 1, : 2, : : : 1, : 1, : 1, : 2, : 2, : 3, : 4, : 4, : 5, : : : 1, : 1, : 1,600 Number of pole 3, 4 3, 4 Rated insulation voltage [Ui] (V) AC1,000 AC1,000 Rated operation voltage [Ue] (V) AC690 AC690 Rated frequency (Hz) 50/60 50/60 Setting current of protection relay (A, x In max.) Rated current of netural pole (%, x In) 100% 100% Rated breaking capacity [Icu, Ics] (ka sym) IEC Category "B" KS C 4620 Rated making capacity [Icm] (ka peak) IEC Category "B" KS C : 2, : 2, : 3,200 AC690/600/550V (65) 1) AC500/480/460V AC415/380/230/220V AC690/600/550V AC500/480/460V AC415/380/230/220V Rated impulse withstand voltage [Uimp] (kv) Rated short-time withstand current [Icw] (ka r.m.s) 1sec sec sec Total breaking time (ms) Closing operating time (max) Motor charging time (sec) max. 1) 70kA is test value at KEMA, 65kA is at KS Closing time (ms) below 80 below HYUNDAI HEAVY INDUSTRIES

19 MCCB MINIATURE MC ACB VC VCB Full Line-up 460mm 368mm A frame [85kA] 630-2,000A (UAN) 630-1,600A (UAS) B frame [100kA] 2,000-4,000A (UAN) 2,000-3,200A (UAS) C frame [100kA] 4,000-5,000A (UAN) D frame [150kA] 4,000-6,300A (UAN) 328mm 399mm 624mm 766mm High Performance Protection Trip Relay (OCR) Application General feeder Generator UPR-1L-GL UPR-2L-GS UPR-1D-GT UPR-2L-GM UPR-1S-AL UPR-2S-AS Externals Power supply Protection Indication Output contact Optional function : Standard : Option Control power - - Self power Long time delay (LTD) Short time delay (STD) Instantaneous trip (INST) Pre trip alarm - - Ground fault trip - - Field test - - Failsafe True RMS detection Fault indication LED - - Overload indication LED - - Display window - - Integrated instantaneous - - PTA: 1a - contact (1a) L/S/I/G: 2a Individual continuous contact (4a) - PTA: 1a L/S/I/G: 2a MCR Temperature detection Event/Fault recording - - Earth leakage trip (ELT) Communication LTD: 1a S/I: 1a PTA:1a 19

20 LV & MV Circuit Breaker, Contactor & Overload Relay Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling squirrel cage and slipring motors, medium voltage loads and resistance furnaces, and capacitors and transformers. Qualified Standard & Approval Standard IEC UL 347 NEMA ICS 3 Approval ISO 18001, 14001, 9001 KERI UL, c-ul KR, GL, LR, NK UVC Type Ratings Structure Fixed type X1 Without fuse holder A1 A2 A3 With single fuse holder Draw-out type B1 B2 Without fuse holder D1 - D6 With single fuse holder Operating method Continuously energized 32C ァ 34C ァ 62C ァ 64C ァ 32C ァ 34C ァ 62C ァ 64C ァ Latched 32L ァ 34L ァ 62L ァ 64L ァ 32L ァ 34L ァ 62L ァ 64L ァ Rated insulation voltage (kv) Rated operation voltage (kv) Rated frequency (Hz) 50/60 Rated current (A) Withstand voltage Impulse (kv) 60 Power frequency (1min, kv) 20 Control dielectric strength(min, kv) 2 Utilization category AC3 Breaking capacity Short-time current (ka) Mechanical lifetime 4kA (O-3min-CO-3min-CO, 50MVA at 7.2kV) 1sec sec 3 Continuously energized (1,000times) 1,000 Latched (1,000times) 300 Electrical lifetime (1,000times) 300 Control voltage (V) Auxiliary contact Applicable load capacity AC/DC , AC/DC Motor (kw) 750 1,500 1,500 3, ,500 1,500 3,000 Transformer (kva) 1,000 2,000 2,000 4,000 1,000 2,000 2,000 4,000 Condensor (kvar) 750 1,200 1,500 2, ,200 1,500 2,000 3a2b Weight without fuse (kg) X1 19 A1 A2 28 A3 33 B1 B2 35 D1 D2 D3 D5 38 D4 D HYUNDAI HEAVY INDUSTRIES

21 MCCB MINIATURE MC ACB VC VCB HCA Type Structure Fixed type F Without fuse holder Draw-out type B Without fuse holder Ratings A With single fuse holder D With single fuse holder J With double fuse holder 1) H With double fuse holder 1) Operating method Continuously energized 32C ァ 34C ァ 62C ァ 64C ァ 82C ァ 84C ァ 32C ァ 34C ァ 62C ァ 64C ァ 82C ァ 84C ァ Latched 32L ァ 34L ァ 62L ァ 64L ァ 82L ァ 84L ァ 32L ァ 34L ァ 62L ァ 64L ァ 82L ァ 84L ァ Rated insulation voltage (kv) Rated operation voltage (kv) Rated frequency (Hz) 50/60 Rated current (A) Withstand voltage Impulse (kv) Power frequency (1min, kv) Control dielectric strength(min, kv) Utilization category AC3 AC4 AC3 AC4 Breaking capacity Short-time current (ka) Mechanical lifetime 4kA (O-3min-CO-3min-CO) 1sec sec Continuously energized (1,000times) 1,000 1,000 1,000 1,000 1,000 1,000 Latched (1,000times) Electrical lifetime (1,000times) 300 Control voltage (V) AC110/125/220, DC110/125/220 Auxiliary contact 2a2b 2) 3a3b 2a2b 2) 5a5b Applicable load capacity Motor (kw) 750 1,500 1,500 3,000 3,000 6, ,500 1,500 3,000 3,000 6,000 Transformer (kva) 1,000 2,000 2,000 4,000 4,000 8,000 1,000 2,000 2,000 4,000 4,000 8,000 Condensor (kvar) 750 1,200 1,500 2,000 3,000 4, ,200 1,500 2,000 3,000 4,000 Weight without fuse (kg) F 21 A 30 J 33 F 22 A 32 J 35 F 61 A 68 B 383) D 40 3) H 43 3) B 413) D 43 3) H 46 3) B 804) D 83 4) 1) Double fuse holder is not applicable to 12kV. 2) In case of 3.6/7.2kV fixed type without fuse holder, 3a3b is standard. 3) The weight of 3.6/7.2kV draw-out type is based on F1 cradle. 4) The weight of 12kV draw-out type is measured without cradle. 21

22 LV & MV Circuit Breaker, Contactor & Overload Relay Vacuum Circuit Breaker HYUNDAI Vacuum Circuit Breaker achieves the superior reputation with its easy maintenance, and excellent performance for industrial facilities, power plants, and vessels. Qualified Standard & Approval Standard IEC , ESB 150 ANSI C37.09 KSC 4611 GOST-R Approval ISO 18001, 14001, 9001 KEMA KERI KR, GL IEC HVF type HVG type Type HVF Withstand voltage (kv) Rated Power-frequency/ voltage (kv) Impulse / /75 42/ / 95 24/ /125 (65/125) 2) Rated breaking current (ka) 1) Rated current (A) 1) ,250 2,000 2,500 3,150 4, HVF114 ァ 31.5 HVF115 ァ 40 HVF116 ァ 50 HVF117 ァ 25 HVF214 ァ 31.5 HVF215 ァ 40 HVF216 ァ 50 HVF217 ァ 25 HVF224 ァ 2) 31.5 HVF225 ァ 2) 40 HVF226 ァ 2) 25 HVF314 ァ 31.5 HVF315 ァ 40 HVF316 ァ 12.5 HVF611 ァ 2) 25 HVF614 ァ 2) 40 HVF616 ァ 24 65/ HVF625 ァ 2) 36 70/ HVF714 ァ 31.5 HVF705 ァ 36/ / HVF725 ァ 2) HVG /60 8 HVG109 ァ 12.5 HVG101 ァ 20 HVG113 ァ 25 HVG114 ァ 1) number in the square " ァ " shall be listed as below for the rated current according to applied standard. - IEC standard: 630A 1,250A 2,000A 2,500A 3,150A 4,000A 400A 2) HVF224 ァ, 225 ァ, 226 ァ, 611 ァ, 614 ァ, 625 ァ, 725 ァ are applicable to GOST-R standard. 22 HYUNDAI HEAVY INDUSTRIES

23 MCCB MINIATURE MC ACB VC VCB ANSI C kV 38kV Type HVF Withstand voltage (kv) Rated Power-frequency/ voltage (kv) Impulse / / /150 Rated breaking current (ka) 25 1) Rated current (A) 1) 1,200 2,000 2,500 3,000 4,000 HVF154 ァ 2) HVF144 ァ 3) 40 HVF146 ァ 3) 50 HVF147 ァ 3) 25 HVF354 ァ 2) HVF344 ァ 3) 40 HVF346 ァ 3) 31.5 HVF705 ァ 4) 40 HVF706 ァ 4) 1) number in the square " ァ " shall be listed as below for the rated current according to applied standard. - ANSI standard: 1,200A 2,000A 2,500A 3,000A 4,000A 2) The pole distance of HVF154 ァ, 354 ァ is 6.5inch (165mm). 3) The pole distance of HVF144 ァ, 146 ァ, 344 ァ, 346 ァ is 10inch (254mm). 4) The pole distance of HVF705 ァ, 706 ァ is 10inch (275mm). 23

24 HHIS-WC-LE-A39-16, Designed by JC Creative Head Office 1000, Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea Tel: ~8 Fax: Seoul 75, Yulgok-ro, Jongno-gu, Seoul, Korea (Sales & Marketing) Tel: , 7620 Fax: Atlanta London Moscow Madrid Tokyo Osaka Mumbai Riyadh Dubai Kuwait Sofia Alabama Vladivostok Yangzhong 6100 Atlantic Boulevard, Norcross, GA 30071, USA Tel: Fax: nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UK Tel: Fax: World Trade Center, Ent. 3# 703, Krasnopresnenskaya Nab. 12, Moscow, , Russia Tel: Fax: Paseo De La Castellana 216, Planta 0, Madrid, Spain Tel: , Fax: th Floor, North Tower Yurakucho Denki Bldg., Yuraku-cho, Chiyoda-ku, Tokyo , Japan Tel: Fax: I-Room 5th Floor Nagahori Plaza Bldg Minami Senba, Chuo-ku, Osaka, , Japan Tel: ~7 Fax: th Floor, East Quadrant, The IL & FS Financial Centre, Plot No. C-22, G-Block, Bandra-kurla Complex, Bandra(E), Mumbai , India Tel: ~26 Fax: Office No. 230, 2nd Floor, 4th Akariya Plaza Olaya Street, PO Box 8072, Riyadh 11485, Saudi Arabia Tel: Fax: Unit 205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox , Dubai, UAE Tel: Fax: th Floor, Al-Sour Tower, Al Sour Street, Al-Qiblah, Kuwait Tel: Fax: Sofia 41, Rojen Blvd., Bulgaria Tel: , 3220 Fax: Folmar Parkway, Montgomery, AL 36105, USA Tel: Fax: str. Potemkina, Artem, Primorskiy Krai, , Russia Tel: Fax: No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: , China Tel: , 0212 Fax: , 0231

HYUNDAI U-Series. Molded Case Circuit Breaker

HYUNDAI U-Series. Molded Case Circuit Breaker HYUNDAI U-Series Molded Case Circuit Breaker U-Series Molded Case Circuit Breaker Wide and Powerful Range UAB, UCB [ up to 1600AF ] Compact Size High breaking capacity in 60mm depth, up to 2AF Application

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D

More information

Metal-Clad Switchgear

Metal-Clad Switchgear HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear Internal Arc Proof Switchgear HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear [ Internal Arc Proof ] CONTENTS 04 General 06 Construction 10

More information

Gas Insulated Switchgear

Gas Insulated Switchgear Gas Insulated Switchgear from 72.5 kv to 800 kv Gas Insulated Switchgear HYUNDAI Gas Insulated Switchgear Manufacturing up to 800 kv Wide range of products to fit any customer requirements Designed and

More information

LV & MV Circuit Breakers, Contactors & Overload Relays

LV & MV Circuit Breakers, Contactors & Overload Relays LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low

More information

LV & MV Circuit Breaker, Contactor & Overload Relay

LV & MV Circuit Breaker, Contactor & Overload Relay LV & MV Circuit Breaker, Contactor & Overload Relay LV & MV Circuit Breaker Full Line up www.hyundai-elec.com LV & MV Circuit Breaker, Contactor & Overload Relay Hyundai Circuit Breaker is one of the most

More information

MCB-EE.ELCB-RCCB (Made in Korea)

MCB-EE.ELCB-RCCB (Made in Korea) MCB-EE.ELCB-RCCB (Made in Korea) Rated Current Breaking Current Unit Price HiBD63 (1P) 5-10-15-20-25-32-40-50-63A 6 54,000 HiBD63 (2P) 5-10-15-20-25-32-40-50-63A 6 120,000 HiBD63 (3P) 5-10-15-20-25-32-40-50-63A

More information

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance M E T A L - C L A D S W I T C H G E A R Safe and Reliable Flexible, Compact Design Easy Installation and Maintenance We build a better future! Hyundai HMS medium-voltage metal-clad switchgears and control-gears,

More information

Ensuring excellent switching capability and high quality with various advantages

Ensuring excellent switching capability and high quality with various advantages VCB Vacuum Circuit Breaker Ensuring excellent switching capability and high quality with various advantages Retaining the high dielectric strength with the interrupter of the high vacuum degree of 10-7

More information

We build a better future!

We build a better future! We build a better future! C O N T E N T S 3 4 5 6 7 15 17 17 18 20 21 39 Description Application Selection Guide Arc-quenching System Type & Rating Construction & Operation Current Carrying Capacity Standard

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling

More information

JDA. JD Auspice Co., Ltd. Catalogue

JDA. JD Auspice Co., Ltd. Catalogue Catalogue Switch-Disconnectors TD series Frame size [AF] Conventional thermal current, Ith [A] No. of poles Rated operational voltage, AC [V] Ue Rated operational current, Ie DC [V] Rated impulse withstand

More information

HYUNDAI INVERTER Powerful Operation & High Performance

HYUNDAI INVERTER Powerful Operation & High Performance HYUNDAI INVERTER Powerful Operation & High Performance HYUNDAI Hyundai Heavy Industries realizes the satisfaction of customer with its best products. Hyundai N-Series inverters with characteristics of

More information

Miniature Circuit Breakers BK63HU / BK63H

Miniature Circuit Breakers BK63HU / BK63H Miniature Circuit Breakers BK63HU / BK63H BK63H UL89 Ratings BK63HU 1P BK63HU 2P BK63HU 3P Performance UL89 Standard UL89, UL86E(Lug) Protection Overload, Short circuit Rated current 1, 2, 3,, 5, 6, 8,

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

10-750kW / DOOSAN Engine Mounted Control Panel kW / MTU Engine Floor-Standing Control Panel

10-750kW / DOOSAN Engine Mounted Control Panel kW / MTU Engine Floor-Standing Control Panel HHI, Hyundai Heavy Industries Co. Ltd., is one of the world s leading synchronous Diesel Generator Set manufacturers. With proven performance, Hyundai s Diesel Generator Sets meet or exceed our customer

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Hyundai Cast-Resin Transformer

Hyundai Cast-Resin Transformer Hyundai CastResin Transformer Hyundai Heavy Industries, Global Leader We Are Your Best Business Partner Hyundai Heavy Industries has solidified its presence on the global market through its strong enterprise

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Total Solution. for Electrical Industry

Total Solution. for Electrical Industry Total Solution for Electrical Industry We build a better Future! Dear Sirs, It is our great pleasure to present this brochure for our esteemed customers and friends over the world to be able to understand

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

HYUNDAI INVERTER Powerful Operation & High Performance

HYUNDAI INVERTER Powerful Operation & High Performance HYUNDAI INVERTER Powerful Operation & High Performance HYUNDAI Hyundai Heavy Industries realizes the satisfaction of customer with its best products. Hyundai N-Series inverters with characteristics of

More information

The effective choice The benefits of a product with the highest quality standards

The effective choice The benefits of a product with the highest quality standards The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

HYUNDAI Electro Electric Systems

HYUNDAI Electro Electric Systems HYUNDAI Electro Electric Systems Keeping a Green Step As an integral division of Hyundai Heavy Industries, Electro Electric Systems ( HHI ) has been designing, engineering and manufacturing electrical

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information