1 LV & MV Circuit Breaker, Contactor & Overload Relay

2 LV & MV Circuit Breaker Full Line up

3 LV & MV Circuit Breaker, Contactor & Overload Relay Hyundai Circuit Breaker is one of the most reliable and sophisticated products, which realizes the optimum design through electric and kinetic analysis. Contents 04 _Molded Case Circuit Breaker 06 _Miniature Series 08 _Contactor &Overload Relay 14 _Air Circuit Breaker 16 _Load Break Switch 17 _Vacuum Contactor 18 _Vacuum Circuit Breaker

4 04 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Molded Case Circuit Breaker Optimum design provides easy-to-use customer installation, while offering versatility and high performance to match today's demand for a reliable and cost-effective product, which is easy to maintain. Q ualified & Approval NEMA AB-1 KS C821 Approval ISO 18001,101,9001 CE (Community European / TU. V Rheinland) TSE GOST-R CCC KR,LR,ABS,BV,NK,GL HiBS HiBL20NE HiBS80NE Frame Molded Case Circuit Breaker 1.Fixed thermal type HiBS0 1) 0 HiBH0 1) HiBE 1) HiBS 1) HiBH 1) HiBE ) HiBS60 1) HiBE 1) HiBS 1) HiBH 1) HiBE2 1) 2 HiBS2 1) HiBH2 1) HiBE0 1) HiBS0 0 1) HiBH0 1) HiBL0 1) HiBE600 1) HiBS600 1) 600 HiBH600 1) HiBL600 1) HiBE800 1) HiBS800 1) 800 HiBH800 1) HiBL800 1) 2.Adjustable thermal type 2 2 HiBLNT HiBXNT HiBSJ 1) HiBHJ 1) HiBLNT HiBXNT HiBL2NT HiBX2NT HiBE2J 1) HiBS2J 1) HiBH2J 1) Number of pole 2, 2, Breaking capacity [Icu] (ka rms) 220/2V 80/415V 600V /5 14/ 7.5/5 14/ 0/ 7.5/5 14/ 14/ 0/ 42/6 /18 0/ 42/ / 42/ /18 0/ 42/6 1) Ics = % Icu 2) 2pole has same dimension with pole,but the middle pole is removed Frame.Electronic type HiBLNE HiBLNE 2 HiBL2NE HiBS0NE 0 HiBL0NE HiBX0NE HiBS600NE 600 HiBL600NE HiBX600NE HiBS800NE 1) 800 HiBL800NE 1) HiBX800NE 1) HiBS0NE 0 1) HiBL0NE 1) HiBS1200NE ) HiBL1200NE 1) Switch disconnector HiSD5 HiSD HiSD20 HiSD HiSD60 HiSD80 HiSDNE HiSD60NE HiSD80NE HiSDNE HiSD120NE Number of pole Breaking capacity [Icu] (ka rms) 220/2V 80/415V 600V Mini safety breaker for distribution and lighting protection 0 HiBC2S 1) HiBC2SC 1) HiBC2 1) HiBC2H 1) HiBD0F 1) HiBDF 1) HiBDF 1) , 2, 2, P1E 2P1E with plastic case 2P2E 2P2E Mini breaker for american area HBDD 1) HBD 1) HBDH 1) 1,2, 1,2, 1,2, Same dimension with HiBS5 Same dimension with HiBS Same dimension with HiBS20 Same dimension with HiBS Same dimension with HiBS60 Same dimension with HiBS80 Same dimension with HiBSNE Same dimension with HiBS60NE Same dimension with HiBS80NE Same dimension with HiBSNE Same dimension with HiBS120NE Plug-in type Lug type Plug-in type

5 05 MCCB MINIATURE MC ACB LBS VC VCB Accessories Interpole barrier [TQ Q ] Terminal cover [TCF ] Cage terminal block [CTB ] M ounting base for plug-in [TDM ] Auxiliary switch [AUX ] Trip alarm switch [ALT ] M otor operator [M OT ] Shunt trip [SH T ] Surface type operating handle [TFG ] Under voltage trip [UVT ] Extended type operating handle [TFH ] Cage terminal block [CTB ] Terminal cover [TCF ] Interpole barrier [TQ Q ] Above features are accessories for HiBS.Different accessories shall be applied to different model.

6 06 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Miniature Series M iniature Circuit Breaker [M CB ] Residual Current Circuit Breaker [RCCB ] Residual Current Circuit Breaker with Overcurrent Protection [RCBO ] M iniature Switch D isconnector [M SD ] H yundai M iniature Series are the perfect solution to protect electric overload, short circuit and earth leakage in the household and commercial installations. W ith consistent and elegant appearances, the H yundai M iniature Series provide various selection, easy installation, economic benefit and high reliability based on international standard. Q ualified & Approval Approval ISO 18001,101,9001 CE BV GOST-R TSE HiBD6-N HiBD6h Miniature Circuit Breaker Number of pole (P) Characteristic I/In Rated current (A) Rated voltage (V) Breaking capacity (A) Accessory Protection HiBD6-E 1,2, 5- In (C) 1,,5,6,, 1,15,16,20,, 2, AC2/415 1),000 AUX,ALARM SHUNT,UVT Overload, Short circuit EN HiBD6-S 1,2, 5- In (C) 1,,5,6,, 1,15,16,20,, 2, AC2/415 1) 4,0 AUX,ALARM SHUNT,UVT Overload, Short circuit EN HiBD6-N 1, 1+N,+N -5 In (B) 5- In (C) -20 In (D) 1,,5,6,, 1,15,16,20,, 2,,,6 AC2/415 1) 6,000 AUX,ALARM SHUNT,UVT Overload, Short circuit EN HiBD6h 1, 1+N,+N -5 In (B) 5- In (C) -20 In (D) 1,,5,6,, 1,15,16,20,, 2,,,6 AC2/415 1),000 AUX,ALARM SHUNT,UVT Overload, Short circuit EN HiBD1 1, 1+N,+N -5 In (B) 5- In (C) -20 In (D) 6,80,,1 AC2/415 1),000 AUX,ALARM SHUNT,UVT Overload, Short circuit EN ) In case of 1pole,MCB will be applicable to AC2V.

7 07 MCCB MINIATURE MC ACB LBS VC VCB Residual Current Circuit Breaker HiRC6 Number of pole 2,4 Residual current characteristics A/AC Rated current,2,,6a Rated residual operating current In,0,,00,0mA Rated voltage AC2/415V 1) Protection Earth leakage 68/EN 68 1) In case of 2pole,RCCB will be applicable to AC2V. HiRC6 Residual Current Circuit Breaker w ith O vercurrent Protection HiRO Number of pole Residual current characteristics Characteristic I/ In Rated current Rated residual operating current In Rated voltage Protection 1+N AC -5 In (B) 5- In (C) -20 In (D) 1,,5,6,,16,20,,2,A,0,,00,0mA AC2V Earth leakage,overcurrent 69/EN 69 HiRO Miniature Sw itch D isconnector HiSD1 Number of pole Rated current Rated voltage Electro-mechanical endurance Function 1, 16,2,6,,1A AC2/415V,000times Isolation /EN HiSD1

8 08 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Contactor & O verload Relay Magnetic Contactor H YU N D AIM agnetic Contactor employs a modular design, which allows quick and simple mounting of auxiliary contact blocks, timers, mechanical latching blocks, etc. H im C Contactor provides convenience, economic benefit and high reliability. W ith highly advanced design for industrial applications such as motor control centers, the H im C contactor is appropriate for various control systems.it is also favored by shipyards and power plants whose criteria includes high reliability and performance. Q ualified & Approval EN UL 8 BS 47794,BS 5424,BS 4941 VDE 0660 DNV KS C44 JISC 828,JEM 8 Approval ISO 18001,101,9001 UL / C-UL CE (Community European / TU. V Rheinland) TSE GOST-R CCC KR,LR,ABS,BV,NK Capacity (AC,kW /A) 220-2V 80-4V 0-5V V 1,000V Auxiliary contact Operation current HiMC9 2.2 / 4 / 9 4 / / 7 1a1b AC,DC HiMC12.7 / / / / 9 1a1b AC,DC HiMC / / / / 9 1a1b AC,DC HiMC / / / / 18 1a1b AC,DC HiMC2 7.5 / 2 15 / / / 22 2a2b AC,DC HiMC 11 / 18.5 / 22 / 2 22 / 26 2a2b AC,DC HiMC 15 / 22 / 0 / 45 / 1 AC,DC HiMC 18.5 / 70 0 / 7 / 60 7 / 44 HiMC80 22 / 80 7 / / / 52 HiMC90 / / 90 / 80 / 60 HiMC1,HiMC1B 2) 0 / 1 55 / 1 60 / 1 55 / / HiMC10 7 / 10 / / / / 54 HiMC1,HiMC1B 2) 45 / 1 75 / 1 90 / 1 90 / 90 / 66 HiMC / / / / / 78 HiMC220 6 / / / / 1 12 / 96 HiMC260,HiMC260B 2) 75 / / / / / 11 HiMC00 90 / / / / / 141 HiMC0 1 / / / 2 / 00 2 / 178 HiMC0 1 / 0 2 / 0 00 / 426 / / 192 HiMC / 60 0 / 60 0 / 0 0 / / 21 HiMC / / / / 60 0 / 284 1) The auxiliary contact for DC is 2a1b. 2) HiMC1B,HiMC1B,HiMC260B:Compact type.

9 09 MCCB MINIATURE MC ACB LBS VC VCB H imc9- H imc- 800 Contactor :HiMC9-800 Auxiliary contact block Mechanical latching block Electronic timer block Mechanical interlock unit Surge absorber Insulation barrier unit Thermal overload relay Digital motor protection relay

10 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Contactor & O verload Relay Therm al O verload Relay HiTH HiTH90 HiTH10 Setting range A A 0.-0.A A A A A A A 2-A A -5A 4-6A 5.6-8A 7-A 9-1A 12-18A 16-22A 18-26A 24-2A 28-A 6-A 45-A 60-80A 48-80A 78-10A 8-180A A A 2-0A 00-0A 78-60A A Applied contactor HiTH22 HiTH HiTH HiTH90 HiTH10 HiTH220 HiTH00 HiTH0 HiTH800 HiMC9 HiMC12 HiMC18 HiMC22 HiMC0 HiMC HiMC HiMC HiMC80 HiMC90 HiMC1B HiMC1 HiMC10 HiMC1B HiMC1 HiMC180 HiMC220 HiMC260B CT operated type HiMC260 HiMC00 HiMC0 HiMC0 HiMC60 HiMC800 Separate Mounting Unit HiTHMB22 HiTHMB HiTHMB HiTHMB90 For use with overload relay HiTH22 HiTH HiTH HiTH90 Mounting DIN rail,screw Saparate mounting unit (HiTHMB)

11 11 MCCB MINIATURE MC ACB LBS VC VCB D igital Motor Protection Relay type Deluxe type Type Over current Phase failure Function Phase unbalance Restriction Reverse phase W iring of main circuit Pin Screw Tunnel Allowable current partition HiMP22K I HiMPK I HiMPK I HiMP1K I HiMP00K I HiMP22K N HiMPK N HiMPK N HiMP1K N HiMP00K N Inverse Inverse Inverse/ Reverse Inverse/ Reverse HiMP22: A,1-5A, A HiMP:8- A HiMP:- A HiMP1:0-1A HiMP00:60-00A HiMP22: A,1-5A, A HiMP:8- A HiMP:- A HiMP1:0-1A HiMP00:60-00A D eluxe Type Over current Under current Phase failure Function Phase unbalance Restriction Reverse phase Short circuit Leakage current W iring of main circuit Screw Tunnel Allowable current partition HiMP60K S HiMP60K I 0.5-6A,5-60A HiMP60K Z Control Relay Auxiliary contact Operation current HMX22 HMX1 2a2b a1b AC HMX 4a HMT22 HMT1 2a2b a1b DC HMT 4a HMT & HMX

12 12 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Contactor & O verload Relay HiAC22 HiAC20 HiAL11 HiAL5 HiAR6 HiMK Capacitor Sw itching Contactor (AC operation) HiMK9 21 HiMK9 12 HiMK12 21 HiMK12 12 HiMK18 21 HiMK18 12 HiMK22 21 HiMK22 12 HiMK2 2 HiMK2 2 HiMK 2 HiMK 2 HiMK 2 HiMK 2 Rating of -phase capacitor -60Hz (at ambient temperature 55 Max. power AC-6b 200V 20V 0V 4V 0V 690V 2V 415V 5V kvar kvar kvar kvar kvar kvar Contactor (AC operation) HiMC HiMC HiMC HiMC HiMC HiMC HiMC Composed devices Capacitor switching unit Auxiliary NO NC (5-54) (51-52) HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 HiAD 1 HiAD 01 1 Dimension External size W x H x D (mm) 44 x 166 x 12 6 x 166 x x 178 x 16 Auxiliary Contact Block HiAB22 HiAB1 HiAB1 HiAB04 HiAB HiAB11 HiAB02 HiAB20 HiAL11 1) HiAC22 HiAC1 HiAC1 HiAC HiAC11 HiAC02 HiAC20 HiAL5 HiAR6 HiAL7 HiAR8 Contact 2NO + 2NC 1NO + NC NO + 1NC 0NO + 4NC 4NO + 0NC 1NO + 1NC 0NO + 2NC 2NO + 0NC 1NO + 1NC 2NO + 2NC 1NO + NC NO + 1NC 4NO + 0NC 1NO + 1NC 0NO + 2NC 2NO + 0NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC Mounting Left side Left side Right side Left side Right side 1) The side mounting auxiliary contact block shall not be used with the top mounting auxiliary.contact block at the same time. Application HiMC9- HiMC9-22 HMX HMT HiMC,80,90,1B- 1B HiMC1-800

13 1 MCCB MINIATURE MC ACB LBS VC VCB Electronic Tim er Control voltage Delay time HOKZE1 HOKZE2 AC / DC90-2V AC / DC24-60V sec sec HOKZE Mechanical Latching Block HLB2 Control voltage AC24,48,1,220,4V / DC24,48,1,220V HLB2 Mechanical Interlock Unit HiTL HiTL HiTL10 HiTL220 HiTL00 HiTL800 Applied contactors HiMC9- HiMC HiMC-10,1B HiMC1-220,260B HiMC HiMC0-800 HiTL220 Surge Absorber Control voltage Application HRC AC28-48V HMX HRC AC1-220V HiMC9- HRC AC2-80V HRC90 HRC90 HRC90 HRC00 HRC00 HRC00 HOKYZX8 AC28-48V AC1-220V AC2-80V AC28-48V AC1-220V AC2-80V DC HiMC- 1B HiMC1-00 HMT,HiMC9- HRC Diagram

14 14 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Air Circuit Breaker D esigned for both industrial and marine application, H YU N D AIAir Circuit Breakers have innovated structure, various protection, and reliable performance. Q ualified & Approval EN AS NEMA PUB NO.SG ANSI C7.1 GOST-R GOST-R Approval ISO 18001,101,9001 GOST-R CCC KR,GL,LR,ABS,BV,NK CE (Community European / TU. V Rheinland) KERI H ias Type Rated current (A) Number of pole Utilization category Rated insulation voltage (Ui) (V) Rated operation voltage (Ue) (V) Rated breaking capacity (ka sym) [Icu] with Inst. Icu=% Ics Rated making capacity (ka peak) [Icm] with Inst. Icu=% Ics AC690V AC0V AC415V below AC690V AC0V AC415V below Rated impulse withstand voltage (Uimp) (kv) HiAS Type HiAS06 HiAS08 HiAS HiAS12 HiAS16 HiAS20 HiAS HiAS ,000 1,2 1,600 2,000 2,0,200 B AC1,000 AC Rated short-time withstand current [Icw] (rms) 1 sec Rated latching current (kv) Total breaking time (sec) Closing operating time W eight (kg) Charging time (sec) max. Closing time (sec) max. pole,fixed type pole,draw-out type 4pole,Fixed type 4pole,Draw-out type Dimensions (mm) (pole,draw-out type) Height W idth Depth

15 15 MCCB MINIATURE MC ACB LBS VC VCB Front View of H ian and H iah Type Control circuit option Lafting lug option Fixing block option Cycle counter Close/Open indicator Front cover Draw-in/out handle Charging handle Charged/Discharged indicator Close button Open button Name plate Cradle Protection relay Position indicator and draw-in/out handle option Key lock device H ian and H iah Type Rated current (A) Number of pole Utilization category Rated insulation voltage (Ui) (V) Rated operation voltage (Ue) (V) Rated breaking capacity (ka sym) [Icu] with Inst. Icu=% Ics Rated making capacity (ka peak) [Icm] with Inst. Icu=% Ics AC690V AC0V AC415V below AC690V AC0V AC415V below Rated impulse withstand voltage (Uimp) (kv) HiAN06 HiAN08 HiAN HiAN12 HiAN16 HiAN20 HiAN HiAN2 HiAN HiAN HiAN6 HiAH ,000 1,2 1,600 2,000 2,0,200 4,000 5,000 6,00,200 B AC1,000 AC Rated short-time withstand current [Icw] (rms) 1 sec Rated latching current (kv) Total breaking time (sec) Closing operating time W eight (kg) Charging time (sec) max. Closing time (sec) max. pole,fixed type pole,draw-out type 4pole,Fixed type 4pole,Draw-out type Dimensions (mm) (pole,draw-out type) Height W idth Depth

16 16 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay MCCB MINIATURE MC ACB LBS VC VCB Load Break Sw itch H yundai H ilb type Load Break Switch has excellent features to switch on-off medium voltage system with safety concerned.the reliable switch performance is ensured, and the main blade gets minimized damage.furthermore, hydraulic type manual operating device can run the geared method mechanism to secure the accurate operation, and the operating device can be installed at customer convenience. Q ualified & Approval KSC (ES) Approval ISO 18001,101,9001 CE Rated voltage (kv) Rated current (A) Switch class () Number of pole Commercial frequency voltage-resistant Electroencephalo impulse voltage-resistant Current break times Load current Loop current Cable charging current Line charging current No load break times Rated transition current (A) Fuse rating (Attach type) (A) Rated control current (A) Manual operation cable length (m) W eight (kg) Applied standard Features Rated frequency (Hz) Rated short-time current-resistant Rated short-circuit making current (peak) Inter-earth Inter-polarity Inter-earth Inter-polarity 60A 1.5A 60A 16A 4.8A 1.5A Operation Fuse holder Earthing switch HiLB06-SM HiLB06-SE 2 HiLB06-FM HiLB06-FE HiLB06-EM HiLB06-EE HiLB06-AM HiLB06-AE E1,M1 /60 20kA/1sec 52 kv,1min 60kV,1min 1kVp 145kVp times 20times times times times times 1,000times , , ,KSC 4615, (ES) Manual Motor Manual Motor Manual Motor Manual Motor

17 17 LV & M V Circuit Breaker, Contactor & Overload Relay MCCB MINIATURE MC ACB LBS VC VCB Vacuum Contactor H YU N D AIVacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling squirrel cage and slipring motors, medium voltage loads and resistance furnaces, and capacitors and transformers. Q ualified & Approval NEMA ICS Approval ISO 18001,101,9001 KR,GL,LR,NK Type Fixed type F W ithout fuse holder A W ith single fuse holder J W ith double fuse holder 1) Draw-out type B W ithout fuse holder D W ith single fuse holder H W ith double fuse holder 1) Operating method Rated insulation voltage (kv) Rated operation voltage (kv) Rated frequency (Hz) Rated current (A) W ithstand voltage Control dielectric strength(min,kv) Utilization catagory Breaking capacity Short-time current (ka) Mechanical life time Electrical lifetime (1,000 times) Control voltage (V) Auxiliary contact Applicable load capacity Continuously energized Latched Impulse (kv) Power frequency (1min,kV) 1 sec 0 sec Continuously energized (1,000 times) Latched (1,000 times) Motor (kw ) Transformer (kva) Condensor (kvar) 2C 4C 62C 64C 82C 84C 2C 4C 62C 64C 82C 84C 2L 4L 62L 64L 82L 84L 2L 4L 62L 64L 82L 84L / AC AC4 AC AC4 4kA (O-min-CO-min-CO) ,000 1,000 1,000 1,000 1,000 1, AC1/220,DC1/220 2a2b 2) 7 1,0 1,0,000,000 6, ,0 1,0,000,000 6,000 1,000 2,000 2,000 4,000 4,000 8,000 1,000 2,000 2,000 4,000 4,000 8, ,200 1,0 2,000,000 4, ,200 1,0 2,000,000 4,000 F 21 F 22 F 61 B 8 ) B 41 ) B 80 ) W eight without fuse(kg) A 0 A 2 A 68 D ) D 4 ) D 8 ) J J H 4 ) H 46 ) 1) Double fuse holder is not applicable to 12kV. 2) In case of fixed type without fuse holder,ab is standard. ) The weight of draw-out type is based on F1 cradle.

18 18 HYUNDAIHEAVYINDUSTRIES LV & M V Circuit Breaker, Contactor & Overload Relay Vacuum Circuit Breaker H YU N D AIVacuum Circuit Breaker achieves the superior reputation with its extended life expectancy, easy maintenance, and excellent performance for industrial facilities, power plants, and marine vessels. Q ualified & Approval ,60056 ESB 1 ANSI C7 KSC 4611 GOST-R 5-06 Approval ISO 18001,101,9001 KR,GL HVF type HVG type Type HVF HVG Rated voltage (kv) / / Withstand voltage (kv) Power-frequency/ Impulse 19 / / / / 75 6 / 95 8 / 95 / 1 ( / 1) 2) 70 / / / 60 Rated breaking current(ka) Applied standard ANSI ANSI 1) HVF17 HVF114 HVF115 HVF116 HVF117 HVF214 HVF215 HVF216 HVF217 HVF224 2) HVF2 2) HVF226 2) HVF6 HVF14 HVF15 HVF16 HVF611 2) HVF614 2) HVF714 HVF7 2) HVG9 HVG1 HVG11 HVG114 1) number in the square shall be listed as below for the rated current according to applied standard. - standard: 60A 1,2A 2,000A 2,0A,1A 4,000A 0A - ANSI standard: 600A 1,200A 2,000A 2,0A,000A 4,000A 2) HVF224,2,226,611,614,7 are applicable to GOST-R standard. Rated current (A) 1) ,2 2,000 2,0,1 4,000

19 19 MCCB MINIATURE MC ACB LBS VC VCB Type HVF HAF HVG Rated voltage (kv) (.8) 7.2 Withstand voltage (kv) Power-frequency/ Impulse 20 / / 75 / 1 80 / 1 19 / / / 75 6 / 95 / 1 20 / 60 Rated breaking current(ka) Applied standard ANSI ANSI ANSI / ESB / ANSI / ESB HVF type 1) HVF4 HVF5 HVF6 HVF204 HVF205 HVF206 HVF207 HVF601 HVF604 HVF605 HVF606 HVF705 HVF706 HAF7 - HAF4-4 HAF5-4 HAF116 - HAF117 - HAF154-4 HAF175-4 HAF176 - HAF177 - HAF24-4 HAF2-4 HAF26 - HAF611-4 HAF612-4 HAF61-4 HAF614-4 HVG HVG4 Rated current (A) 1) ,2 2,000 2,0,1 1) number in the square shall be listed as below for the rated current according to applied standard. - standard: 60A 1,2A 2,000A 2,0A,1A 4,000A 0A - ANSI standard: 600A 1,200A 2,000A 2,0A,000A 4,000A HAF type

MCB-EE.ELCB-RCCB (Made in Korea)

MCB-EE.ELCB-RCCB (Made in Korea) MCB-EE.ELCB-RCCB (Made in Korea) Rated Current Breaking Current Unit Price HiBD63 (1P) 5-10-15-20-25-32-40-50-63A 6 54,000 HiBD63 (2P) 5-10-15-20-25-32-40-50-63A 6 120,000 HiBD63 (3P) 5-10-15-20-25-32-40-50-63A

More information

LV & MV Circuit Breakers. LV & MV Circuit Breaker, Contactor & Overload Relay

LV & MV Circuit Breakers. LV & MV Circuit Breaker, Contactor & Overload Relay LV & MV Circuit Breakers LV & MV Circuit Breaker, Contactor & Overload Relay Leader of Technology Hyundai Heavy Industries' state-of-the-art technologies have created circuit breakers and contactors for

More information

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling

More information

LV & MV Circuit Breakers, Contactors & Overload Relays

LV & MV Circuit Breakers, Contactors & Overload Relays LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

HYUNDAI U-Series. Molded Case Circuit Breaker

HYUNDAI U-Series. Molded Case Circuit Breaker HYUNDAI U-Series Molded Case Circuit Breaker U-Series Molded Case Circuit Breaker Wide and Powerful Range UAB, UCB [ up to 1600AF ] Compact Size High breaking capacity in 60mm depth, up to 2AF Application

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Uninterruptible Power Supply (UPS)

Uninterruptible Power Supply (UPS) Uninterruptible Power Supply (UPS) Win Dialog Plus / Net Dialog (400VA ~ 2000VA) Line interactive, Pseudo sinewave ITALY Single phase input / output Microprocessor control and mains power supply stabilisation

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

JDA. JD Auspice Co., Ltd. Catalogue

JDA. JD Auspice Co., Ltd. Catalogue Catalogue Switch-Disconnectors TD series Frame size [AF] Conventional thermal current, Ith [A] No. of poles Rated operational voltage, AC [V] Ue Rated operational current, Ie DC [V] Rated impulse withstand

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

We build a better future!

We build a better future! We build a better future! C O N T E N T S 3 4 5 6 7 15 17 17 18 20 21 39 Description Application Selection Guide Arc-quenching System Type & Rating Construction & Operation Current Carrying Capacity Standard

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

High voltage vacuum contactors

High voltage vacuum contactors U-Series High voltage vacuum contactors 2 FEATURES 4 STRUCTURE 5 RATINGS 6 TECHNICAL DATA 11 ACCESSORIES 13 ELECTRIC CIRCUIT DIAGRAM 14 OVERALL DIMENSIONS 20 CONTACTOR SELECTION AND ORDERING 24 OPERATING

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

B4 Load Break Switches

B4 Load Break Switches B4 CONTENTS Features B4-02 Ratings B4-04 Accessories B4-06 Installation Method & Structure B4-08 Control Circuit Diagrams & Dimensions B4-10 Fuse Selection Criterias B4-12 Certifications B4-14 B4-02 LBS

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Circuit Breaker Prepared By :

Circuit Breaker Prepared By : Circuit Breaker Prepared By : Eng : Ayman Soliman Selmy Circuit Breaker Specification of circuit Breaker:- [1] Operating voltage of C.B [2] Rated current of C.B (Ir or In) Amp. [3] Instantaneous short

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers CATALOGUE GLOBAL RANGE 3. ACB Air Circuit Breakers Inde 3. Air Circuit Breakers 3.1 ACB Product Overview Air Circuit Breakers 3.2-3.3 ACB Product Specifications 3.4 ACB Accessories Overview 3.5 ACB Accessory

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

ABB STOTZ-KONTAKT GmbH

ABB STOTZ-KONTAKT GmbH ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information