Hydrants. Waterous WB The Pacer. American-Darling B-84-B. American-Darling B-62-B. Clow Eddy F Abbreviations Common to Hydrants

Size: px
Start display at page:

Download "Hydrants. Waterous WB The Pacer. American-Darling B-84-B. American-Darling B-62-B. Clow Eddy F Abbreviations Common to Hydrants"

Transcription

1

2

3 Revised 6/01 Hydrants Waterous WB The Pacer In 1886, Waterous introduced their line of Frost Jacket fire hydrants. The traffic model WB brings the developments of the last one hundred plus years into the 1990's and beyond. It incorporates the strength and durability of a ductile iron lower barrel and conforms to the latest version of AWWA C-502 specifications for dry-barrel fire hydrants. It is easy to maintain and has a proven record of dependability. American-Darling B-84-B The design and construction of every American- Darling 5 1 4" B-84-B fire hydrant provide for maximum water delivery to nozzles with minimum pressure drop. Features which assure years of uninterrupted service include: positive mechanical drain operation; ability to remove complete working parts assembly, including hydrant valve, drain lever and hydrant seat; simple barrel extensions to accommodate grade changes. American-Darling B-62-B Reliability is the most important requirement in a fire hydrant. This means dependable, efficient operation when needed and is the result of quality design and manufacture to rigid specifications. American-Darling B-62-B hydrants incorporate over 80 years experience in design, manufacture and field experience to make available the utmost in reliability. Clow Eddy F-2640 The Eddy hydrant has existed since The design has proven to be dependable and efficient and one that is easy and simple to maintain. The Eddy's advanced design provides for minimum friction loss and maximum water delivery. Superior engineering, construction and materials assure operational dependability. When the Eddy hydrant does require maintenance, the complete removal and reassembly of the working parts can be accomplished with three ordinary hand tools: an adjustable wrench, a standard screwdriver and pliers. Clow Medallion The Clow Medallion fire hydrant sets new standards for fire protection. The Medallion has earned both Underwriters Laboratory and Factory Mutual approval. It is fully rated for 200 psi working pressure and has a five (5) year limited warranty. Trench or Bury Cover Depth of Trench or Bury = Distance from the ground line to the bottom of the connecting pipe. Depth of Cover = Distance from the ground line to the top of the connecting pipe. Abbreviations Common to Hydrants ANSI... American National Standards Institute AWWA... American Water Works Association; Sets standards only, and does not test or approve any. CI... Cast Iron DI... Ductile Iron FM... Factory Mutual Approved MJ... Mechanical Joint NBR... Nitrile-Butadien Rubber (also known as Nitrile) NRS... Non-Rising Stem NST... National Standard Thread OL... Open Left (counterclockwise) ON... Operating Nut OR... Open Right (clockwise) PR... Pressure Rating PSI... Pounds Per Square Inch SBR... Styrene-Butadien Rubber standard rubber used for all waterworks gaskets UL... Underwriters Laboratories Listed

4 D-1 Waterous Pacer WB D Pacer s Exceptional Features Many years of experience have taught Waterous what customers want in a hydrant. They have applied this knowledge into the Pacer design. As a result it incorporates the best features of all hydrants with additional features not available elsewhere. Pacer is a functionally designed hydrant unmatched in overall convenience. In addition, Pacer meets or exceeds all applicable industry standards. Pacer offers such quality convenience features as: 250 PSI Rating Designed for 250 psi working pressure and tested to 500 psi hydrostatic pressure. All Ductile Iron Construction Its lighter, stronger, smoother and more uniform than hydrants of cast iron construction. 360 Degree Nozzle Rotation The stainless steel retaining ring system allows 360 rotation by merely loosening the flange bolts and turning the nozzle section to the exact position desired. All Bronze Drain No composition, plastic, rubber or leather face to chip, peel or crack. Fusion Bonded Epoxy Coating The interior and exterior of the MJ shoe as well as the upper and lower valve washers are fully coated with fusion applied epoxy. WB Specifications Hydrant shall conform to AWWA C-502 Standard for Dry-Barrel Fire Hydrants. Hydrant shall be the traffic model design with replaceable parts designed to break away without water loss and damage to other parts of the hydrant. Hydrant shall be designed for 250 psi working pressure and tested to 500 psi hydrostatic pressure. Main valve opening shall be a minimum of 5¼". The bronze valve seat shall thread into a bronze subseat. The all bronze drain plunger shall be positively operated by the main operating rod. A travel stop nut shall be used to provide a positive limit to the travel of the main operating rod. The hydrant shall have a two piece operating nut for durability and low maintenance. The nozzle section shall be ductile iron and capable of 360 rotation by simply loosening the four ground flange bolts. Nozzles shall be mechanically attached with a ductile iron retainer and sealed with an O-Ring. The upper and lower standpipe and extensions shall be ductile iron with a minimum inside diameter of 7¼". The MJ shoe and upper and lower valve washers shall be fully coated with a fusion applied epoxy. The MJ shoe shall be attached to the lower barrel with stainless steel bolts and nuts. The MJ shoe shall have a flat bottom, ribbed back and strapping lugs to facilitate installation. The hydrant design shall allow plugging of the drains without excavating. depth of bury direction to Open * Product s are for hydrants with drains. Hydrants without drains are available and are stocked at Team EJP locations in states requiring non-draining hydrants. NOTE: Demonstration trailer and training tapes are available if you would like to learn more about the Waterous Pacer WB hydrant. The WB Hydrant is UL listed and FM approved. * 5' 0" OL ' 6" OL ' 0" OL ' 6" OL ' 0" OL ' 6" OL ' 0" OR ' 6" OR ' 0" OR ' 6" OR ' 0" OR ' 6" OR D-1

5 D-2 Waterous Pacer WB Waterous Pacer WB Construction D-2 Phone: 800-EJP-24HR ( ) Fax:

6 D-3 Waterous Pacer WB D Maintenance Kit WB Break Repair Kit This kit is available to assist you in the routine maintenance of hydrants. It includes such items as main valve rubbers, gaskets, O-Rings, nuts, bolts, snap rings and lubricants. description W Hyd. Maintenance Kit WB Top Extension Kit A hydrant so low that connection of a hose is impossible or difficult is a community hazard. The Waterous Top Extension Kit allows for fast and inexpensive extension of the nozzle section, to any desired height (in 6" increments) in case of grade change. description 6" W Hyd. Top Extension " W Hyd. Top Extension " W Hyd. Top Extension " W Hyd. Top Extension NOTE: Longer length extensions are available by special order. Please call your local Team EJP sales office for price and availability. Need for hydrant repairs is frequently the result of traffic accidents. Since they cannot be eliminated, minimizing the cost of repair is the next best thing. This is being done in many cities by using the Pacer WB Traffic Model Hydrant. The Pacer is designed to break away without water loss and without damaging the lower barrel or other vital parts of the hydrant. Repairs can be made without digging or shutting off the water because the Pacer is a true compression hydrant in which the main valve closes with and is held shut by water pressure. The Traffic Repair Kit makes repairs simple and fast. Only the parts which were so designed will break away on impact. Repair is simply a matter of removing the broken parts and installing new parts, all of which are included in the repair kit. description W Hyd. Break Repair Kit DI D-3

7 D-4 Waterous Pacer WB D-4 WB Parts ref. no. 3 O-Ring Packing Buna-N A Hex HD Bolt, 5 8" -11 x 3¾" Zinc Pltd B Hex HD Bolt, 5 8" x 11 x 3" Zinc Pltd C Hex Nut, 5 8"-11" Zinc Pltd Drain Plunger Red Brass Cotter Pin, ¼" x 1½" Stainless A Nozzle Cap Chain, Single Zinc Pltd B Nozzle Cap Chain, Double Zinc Pltd A Nozzle Cap, Hose Ductile Iron B Nozzle Cap, Pumper Ductile Iron A Hose Nozzle Cap Gasket Neoprene B Pumper Nozzle Cap Gasket Neoprene A Pumper Nozzle Brass B Hose Nozzle Brass Flat HD Screw, ¼-20 x ½" Stainless A Operating Nut, Lower OR Bronze A Operating Nut, Lower OL Bronze B Operating Nut, Upper Ductile Iron Valve Rod Bushing Red Brass Standpipe Ductile Iron ** 30 Crossarm Bronze Valve Seat Bronze Upper Valve Washer Ductile Iron Main Valve Rubber Urethane Lower Valve Washer Ductile Iron Hydrant Bottom Ductile Iron Upper Standpipe Ductile Iron Support Wheel Ductile Iron O-Ring (operating nut) Buna-N O-Ring (support wheel) Buna-N Nozzle Section (OR or OL) Ductile Iron Bury Depth Plate Aluminum Bury Depth Plate Washer Pltd. Steel B Upper Standpipe Flg. (WB ) Ductile Iron Standpipe Flange Ductile Iron Flange Lock Ring Stainless Coupling Sleeve (2 halves) Gray Iron Upper Rod Assembly OR Steel Upper Rod Assembly OL Steel Lower Rod (specify length) Steel O-Ring (upper valve seat) Buna-N Groove Pin 3 32" x 7 16" Ber. Copper Upper Tube Seal Buna-N Lower Tube Seal Buna-N Support Gasket Buna-N Support Tube Ductile Iron Stop Nut OL 1"-8 Pltd. Steel Stop Nut OR 1"-8 Pltd. Steel Coupling Nut ½-20 Brass Coupling Stud ½-20 x " Stainless Nozzle Section Bushing Brass Thrust Ring (Starting Jan. 1970) Teflon Upper Standpipe Gasket Neoprene Pipe Plug, ¼" NPT Brass Breakable Flange Ductile Iron * O-ring (pumper) Buna-N * Pumper Nozzle Retainer Ductile Iron * O-ring (hose nozzle) Buna-N * Hose Nozzle Retainer Ductile Iron Valve Seat Insert Bronze 174 Valve Seat Insert Gasket Nitrile 176 Stud, x 5.650" Stainless description material * Not Shown ** Specify the length of the standpipe when ordering. Phone: 800-EJP-24HR ( ) Fax:

8 D-5 American- Darling B-84-B-5 D Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which may occur if excessive torque is applied in the full open position American Flow Control s American-Darling 5¼" B- 84-B-5 hydrant incorporates more than 80 years of experience in design, manufacture, and field experience. This means dependable and efficient operation when needed. Introduced in 1984, the B-84-B-5 hydrant is rated at 250 p.s.i.g. and is seat tested at 500 p.s.i.g. This hydrant meets or exceeds all requirements of AWWA C502 for dry-barrel hydrants. The B-84-B-5 hydrant is loaded with the features you expect from a high-quality fire hydrant. The all bronze seat and drain ring ensure that the B-84-B-5 hydrant is easily repaired by just one person. Features: Positive compression, fast-closing drains Travel stop located in top of hydrant Bronze-to-bronze seating Short, lightweight, disassembly wrench Easy 360 rotation of nozzle section All bases are epoxy-coated ductile iron Centrifugally cast, high-strength ductile iron lower and upper barrel Sealed lubrication chamber Lower valve ball is epoxy coated Benefits: Spring-Loaded Multiport Drains There are two drain ports and four drain outlets as a standard feature on the B-84-B-5 hydrant. The rod spring assures drains close after approximately three turns of the operating nut. This important safety feature prevents wash-outs that can happen on hydrant designs that do not have this important feature. Specifications: Fire hydrants shall meet or exceed AWWA C502, latest revision. Rated working pressure shall be 250 p.s.i.g., test pressure shall be 500 p.s.i.g., and hydrants shall include the following specific design criteria: The main valve closure shall be of the compression type. Traffic feature to be designed for easy 360º rotation of nozzle section during field installation. The main valve opening shall not be less than 5¼" and be designed so that removal of all working parts can be accomplished without excavating. The bronze seat shall be threaded into mating threads of bronze. The draining system of the hydrant shall be bronze and positively activated by the main operating rod. Hydrant drains shall close completely after no more than three turns of the operating nut. There shall be a minimum of two internal ports and four drain port outlets to the exterior of the hydrant. Drain shutoff to be by direct compression closure. Hydrant barrels shall be made of centrifugally cast ductile iron. Friction loss not to exceed 3.0 p.s.i.g. at 1000 gpm through 4½" pumper nozzle. Hydrants shall be equal to American Flow Control s American- Darling 5¼" B-84-B-5. bury dir. to Open hydrant w/drain hydrant l/drain 5' 0" OL WD ND 5' 6" OL WD ND 6' 0" OL WD ND 6' 6" OL WD ND 7' 0" OL WD ND 7' 6" OL WD ND 5' 0" OR WD ND 5' 6" OR WD ND 6' 0" OR WD ND 6' 6" OR WD ND 7' 0" OR WD ND 7' 6" OR WD ND WD With drains open ND With drains plugged * Hydrants listed are with 1½" Pentagon operating nut and 2 2½" Hose nozzles and 1 4½" Pumper nozzle all NST (national standard). NOTE: Demonstration trailer and training tapes are available. Please call your local Team EJP sales office for more information. D-5

9 D-9 American- Darling B-84-B-5 D B-84-B-5 Break Repair Kit B-84-B-5 Top Extension Kit The B-84-B Break Repair Kit makes it a quick and simple job to repair a hydrant that has been damaged by traffic. This kit contains all the parts needed to replace those parts designed to break away upon impact from a vehicle. description B-84-B Hydrant Break Repair Kit The 5¼" B-84-B hydrant is extended at the barrel flange above the ground line, eliminating any need for excavation. The B-84-B Top Extension Kit (for traffic model hydrants) includes all parts necessary to extend the hydrant. description 6" B-84-B Hydrant Top Extension " B-84-B Hydrant Top Extension " B-84-B Hydrant Top Extension " B-84-B Hydrant Top Extension NOTES: Longer extension barrels are available by special order. Contact your local Team EJP sales office for price and availability. When extending hydrants, the existing breakable coupling must be moved to the top of the new extension barrel to maintain traffic feature. D-9

10 D-6 American- Darling B-84-B-5 5¼" B-84-B-5 Fire Hydrant Construction D-6 Phone: 800-EJP-24HR ( ) Fax:

11 D-7 American- Darling B-84-B-5 D B-84-B-5 Parts Illustration D-7

12 D-8 American- Darling B-84-B-5 Parts List For 5¼" B-84-B-5 Fire Hydrant How to Order Parts The part shown should be prefixed by the following s to designate the size and model of hydrant: 54 for 5¼" valve opening 45 for 4½" valve opening EXAMPLE: 5¼" Operating Nut notes: 1. Size and shape of nut on operating nut and cap, threading on nozzles and caps and the direction of opening made to specifications. 2. Cap chains not furnished unless specified. 3. All gray iron is ASTM A126 class B. 4. Bolts and nuts are rustproofed steel ASTM A307 in accordance with AWWA C Working pressure 250 psig, test pressure 500 psig. 6. Hydrant conforms to AWWA Standard C Upper barrel can be rotated Factory Mutual Approved and Underwriters Laboratories Listed at 200 psig in allowable configurations. 9. Bronze in contact with water contains less than 16% zinc " Mechanical joint base is ductile iron. 11. Nominal turns to open is 19½. part no. qty description material Operating Nut OR Bronze Operating Nut OL Bronze Cover O-ring Buna-N Housing O-ring Buna-N Thrust Washer Nylatron Pipe Plug Stainless Steel Weather Cover OL Gray Iron Weather Cover OR Cast Iron Housing Cover OR-OL Gray Iron Housing Cover Cap Screw See Note Housing Cover Gasket Fiber Housing Gasket Composition Rubber Housing Ductile Iron Housing Bolt and Nut See Note Upper Barrel w/steamer Ductile Iron SR 1 Lower Barrel Ductile Iron " Hose Nozzle NST Bronze (See Note 9) Hose Nozzle O-Ring Buna-N Hose Nozzle Retainer Ductile Iron Hose Nozzle Washer Teflon Hose Cap Gray Iron Hose Cap Gasket Rubber Per Nozzle Nozzle Cap Chain Steel Per Nozzle Cap Chain S-Hook Steel or 0 Pumper Nozzle Bronze (See Note 9) Per Nozzle Pumper Nozzle O-Ring Buna-N Per Nozzle Pumper Nozzle Retainer Ductile Iron Per Nozzle Pumper Nozzle Washer Teflon Per Nozzle Pumper Cap Gray Iron Per Nozzle Pumper Cap Gasket Rubber Non-Breakable Flange Ductile Iron Snap Ring Stainless Steel Break Rod Coupling Gray Iron Rod Cplg. Pin and Clip Pins Stainless/Bronze Breakable Barrel Flange Gray Iron Hydrant Spring Spring Steel Spring Plate Steel Travel Stop Nut OL Bronze (See Note 9) Travel Stop Nut OR Bronze (See Note 9) Spring Plate Pin Steel Upper Hydrant Rod OR Steel Upper Hydrant Rod OL Steel Lower Hydrant Rod Steel Drain Lever Bronze (See Note 9) Drain Lever Washer Rubber Drain Lever Rivet Brass Hydrant Seat Solid Bronze (See Note 9) LD Hydrant Seat Draining Bronze (See Note 9) WD Seat O-ring Buna-N Drain Ring Bronze (See Note 9) Drain Ring Gasket Composition Rubber Barrel Gasket Composition Rubber Base Bolt and Nut Stainless Steel Barrel Bolt and Nut See Note Hydrant Valve Top Gray Iron Cotter Pin Stainless Steel Hydrant Valve Rubber Hydrant Valve Bottom Ductile Iron " Mechanical Joint Base Ductile Iron Weather Shield Rubber Seat Wrench Cast Iron Hose Nozzle Wrench Cast Iron Pumper Nozzle Wrench Cast Iron D-8 Phone: 800-EJP-24HR ( ) Fax:

13 D-10 American- Darling B-62-B-5 Sealed Lubrication Chamber Seals operating threads from grit and moisture and reduces maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which may occur if excessive torque is applied in the full open position. American Flow Control s American- Darling B-62-B-5 hydrant incorporates over 80 years in design, manufacture, and field experience. This means dependable and efficient operation when needed. Introduced in 1962, the B-62-B-5 hydrant is rated at 200 p.s.i.g. and seat tested at 400 p.s.i.g. This hydrant meets and exceeds all requirements of AWWA C502 for dry-barrel hydrants. The B-62-B-5 hydrant is loaded with the features you expect from a high quality fire hydrant. The all bronze seat and bronze drain ring assure that the B-62-B-5 hydrant is easily repaired by just one person. Standard Features: Travel stop located in top of hydrant Bronze-to-bronze seating Positive compression, spring-loaded multiport drains Lower valve ball is epoxy coated Short, lightweight, disassembly wrench Easy 360 rotation of nozzle section Centrifugally cast high-strength ductile iron barrels Ductile iron 6" base with epoxy-coating Sealed lubrication chamber Double O-ring protected bronze valve seat Benefits: Spring-Loaded Multiport Drains Three drain ports and four drain outlets are standard features on the B-62- -B-5 hydrant. The rod spring assures drains close after only three turns of the rod. This important safety feature prevents wash-outs that can happen on hydrant designs that do not have this important feature. Specifications: Fire hydrants shall meet or exceed AWWA C502, latest revision. Rated working pressure shall be 200 p.s.i.g., test pressure shall be 400 p.s.i.g. and hydrants shall include the following specific design criteria: The main valve closure shall be of the compression type, opening against the pressure and closing with the pressure. Traffic feature to be designed for easy 360 rotation of nozzle section during field installation. There shall be a sealed lubrication chamber with triple O-rings to seal operating threads from the waterway and accomodate an anti-friction thrust washer. The main valve opening shall not be less than 5¼" and be designed so that removal of all working parts can be accomplished without excavating. The bronze seat shall be threaded into mating threads of bronze for easy field repair. The draining system of the hydrant shall be bronze and be positively activated by the main operating rod. Hydrant drains shall close completely after no more than three turns of the operating nut. There shall be a minimum of three internal ports and four drain port outlets to the exterior of the hydrant. Drain shutoff to be by direct compression closure. Friction loss not to exceed 3.5 p.s.i.g. at 1000 gpm through 4½" pumper nozzle. Hydrants shall be American Flow Control s American-Darling B-62-B-5. bury dir. to Open hydrant w/drain hydrant l/drain 5' 0" OL WD ND 5' 6" OL WD ND 6' 0" OL WD ND 6' 6" OL WD ND 7' 0" OL WD ND 7' 6" OL WD ND 5' 0" OR WD ND 5' 6" OR WD ND 6' 0" OR WD ND 6' 6" OR WD ND 7' 0" OR WD ND 7' 6" OR WD ND WD With drains open ND With drains plugged * Hydrants listed are with 1½" Pentagon operating nut and 2 2½" Hose nozzles and 1 4½" Pumper nozzle all NST (national standard). NOTE: Demonstration trailer and training tapes are available. Please call your local Team EJP sales office for more information. D-10 Phone: 800-EJP-24HR ( ) Fax:

14 D-11 American- Darling B-62-B-5 D 5¼" B-62-B Fire Hydrant Construction D-11

15 D-12 American- Darling B-62-B-5 5¼" B-62-B Fire Parts Illustration D-12 Phone: 800-EJP-24HR ( ) Fax:

16 D-13 American- Darling B-62-B-5 D How to Order Parts The part shown should be prefixed by the following s to designate the size and model of hydrant: 54 for 5¼" valve opening 62 for Model B-62-B EXAMPLE: 5¼" Operating Nut notes: 1. Size and shape of nut on operating nut and cap, threading on nozzles and caps, and the direction of opening made to specifications. 2. Cap chains are not furnished unless specified. 3. All gray iron is ASTM A126 class B. 4. Bolts and nuts are rustproofed steel ASTM 5. A307 in accordance with AWWA C Working pressure 200 p.s.i.g., test pressure 400 p.s.i.g. 7. Hydrant conforms to AWWA Standard C Upper barrel can be rotated Factory Mutual Approved and Underwriters Laboratories Listed at 200 p.s.i.g. in allowable configurations. 10. Bronze in contact with water contains less than 16 percent zinc inch mechanical joint base is ductile iron. 12. Nominal turns to open is 22. part no. qty description material Operating Nut OR Bronze Operating Nut OL Bronze Cover O-ring Buna-N Housing O-ring Buna-N Thrust Washer Nylatron Pipe Plug Stainless Steel Weather Cover OR Gray Iron Weather Cover OL Gray Iron Housing Cover Gray Iron Housing Cover Cap Screw See Note Housing Cover Gasket Fiber Housing Gasket Composition Rubber Housing Ductile Iron Housing Bolt and Nut See Note Upper Barrel w/pumper Ductile Iron SR 1 Lower Barrel Ductile Iron Hose Nozzle Bronze (See Note 10) Hose Nozzle O-ring Buna-N Hose Nozzle Retainer Ductile Iron Hose Nozzle Washer Teflon Hose Cap Gray Iron Hose Cap Gasket Rubber Per Nozzle Hose Cap Chain Steel Per Nozzle Cap Chain S-Hook Steel or 0 Pumper Nozzle Bronze (See Note 10) Per Nozzle Pumper Nozzle O-ring Buna-N Per Nozzle Pumper Nozzle Retainer Ductile Iron Per Nozzle Pumper Nozzle Washer Teflon Per Nozzle Pumper Cap Gray Iron Per Nozzle Pumper Cap Gasket Rubber Snap Ring Steel Breakable Flange Gray Iron Base Flange Ductile Iron Rod Coupling Breakable Gray Iron Rod Cplg. and Clip Pins Stainless/Bronze Hydrant Spring Spring Steel Spring Plate Steel Travel Stop Nut OL Bronze (See Note 10) Travel Stop Nut OR Bronze (See Note 10) Spring Plate Pin Steel Upper Hydrant Rod OR Steel Upper Hydrant Rod OL Steel Lower Hydrant Rod Steel Drain Lever Bronze (See Note 10) Drain Lever Washer Rubber Drain Lever Rivet Brass OR 1 Hydrant Seat Solid Bronze (See Note 10) LD OR 1 Hydrant Seat Draining Bronze (See Note 10) WD Seat O-ring-Outside Buna-N Seat O-ring-Inside Buna-N OR 1 Drain Ring Bronze (See Note 10) Drain Ring Gasket Composition Rubber Barrel Gasket Composition Rubber Base Gasket Composition Rubber Base SS Bolt and Nut Stainless Steel Barrel Bolt and Nut See Note Hydrant Valve Top Gray Iron Hydrant Valve Rubber Hydrant Valve Bottom Ductile Iron Mechanical Joint Base Ductile Iron Weather Shield Rubber Seat Wrench Cast Iron D-13

17 D-14 American- Darling B-62-B-5 B-62-B Break Repair Kit B-62-B Traffic Model Top Extension Kit The B-62-B Break Repair Kit makes it a quick and simple job to repair a hydrant that has been damaged by traffic. This kit contains all the parts needed to replace those parts designed to break away upon impact from a vehicle. description B-62-B Hyd. Break Repair Kit (1985) B-62-B Hyd. Break Repair Kit (1986) B-62-B QF Hyd. Break Repair Kit The 5¼" B-62-B hydrant is extended at the barrel flange above the ground line, eliminating any need for excavation. The B-62-B Top Extension Kit includes all parts necessary to extend the hydrant. description 6" B-62-B Hydrant Top Extension " B-62-B Hydrant Top Extension " B-62-B Hydrant Top Extension " B-62-B Hydrant Top Extension NOTES: Longer extension barrels are available by special order. Contact your local Team EJP sales office for price and availability. When extending hydrants, the existing breakable coupling must be moved to the top of the new extension barrel to maintain traffic feature. D-14 Phone: 800-EJP-24HR ( ) Fax:

18 D-15 Clow Eddy F-2640 D Eddy F-2640 Features Time Tested Performance same design and parts since 1875 Conforms Fully with AWWA C-502 Opens Easily and Quickly with Pressure Both Drain and Drainless Features are Standard NOTE: If you would like to learn more about the Clow Eddy F-2640 Hydrant please contact your local Team EJP sales office for more information or to schedule a demonstration. 1. Threaded Nozzles: Easy replacement locking pin to hold nozzle in place; O-Ring Seal 2. Rising Stem: Lets you know position of main valve Indicator Feature 3. Independent Drain: Allows plugging of drain without disassembly of hydrant 4. Break Flange Design: For traffic safety 5. Main Valve Closes Against Pressure: Eliminates valve seat damage reducing the slam hazards of water hammer 6. Main Valve Opens With Pressure: Water assists in opening the valve making operation easier, faster and positive 7. Stem Nut Below Ground Line: Maintains positive shut off of main valve after traffic damage Does not depend on water pressure Never needs lubrication Bronze to Bronze Connection NOTE: Epoxy coated shoe provided at no extra cost. D-15

19 D-16 Clow Eddy F-2640 Ordering Information: Quantity of hydrants and accessories required Size of main valve opening: 4½" or 5¼" Size and of hose nozzles Size and of steamer nozzles With or without chains or nozzles Hose and pumper nozzle thread specifications Type of inlet connection Depth of trench or bury Direction of opening Size and shape of operating nut and cap nuts Specify with drain or without drain bury dir. to Open hydrant w/drain Hydrant L/Drain 5' 0" OL ' 6" OL ' 0" OL ' 6" OL ' 0" OL ' 6" OL ' 0" OR ' 6" OR ' 0" OR ' 6" OR ' 0" OR ' 6" OR Specifications: Eddy F-2640 Hydrant with Drain Hydrant shall be center stem type and in accordance with AWWA Standard C Hydrant shall be compression type with the main valve opening with the water pressure and have a rising stem to positively indicate open or closed position. Hydrant shall be furnished with frangible break flange and break coupling at the groundline. Bronze stem threads shall be located below the main valve to eliminate necessity of lubrication and in case of damage to hydrant, main valve will remain mechanically closed. Hydrant shall have minimum valve opening of either 4½" or 5¼", and shoe inlet of 6". Hydrant shall be designed to permit removal of all working parts without special tools or wrenches. Hydrant shall have automatic drain, independent of main valve, to provide removal or adjustment without shutting off water and can be cleaned without digging. Hydrant shall be the Eddy Hydrant, manufactured by the Clow Valve Company. Eddy Top Extension Eddy Break Repair Kit Valve opening Hydrant w/drain hydrant no drain 5¼" size & Length Hydrant w/drain hydrant no drain 5¼" x 6" NS 13 5¼" x 12" NS 13 5¼" x 18" NS 13 5¼" x 24" NS 13 D-16 Phone: 800-EJP-24HR ( ) Fax:

20 D-17 Clow Eddy F-2640 D Eddy F-2640 Parts Part qty description material no. 1 1 Hold Down Bolt Stainless Operating Nut O.L. Cast Iron Operating Nut O.R. Cast Iron Packing Nut Bronze Packing Fiber Cover Cast Iron Cover Bolts & Nuts Steel Swivel Ring Cast Iron Nozzle Section Cast Iron ** Pumper Nozzle Bronze ** Nozzle Chain* Steel ** Pumper Nozzle Cap Cast Iron ** Pumper Cap Washer Rubber Flange Bolts & Nuts Steel Flange Gaskets Accopac ** Hose Nozzle O-Ring* Rubber Pumper Nozzle O-Ring* Rubber ** 2.5" Hose Nozzle Bronze ** 2.5" Hose Nozzle Cap Cast Iron ** 2.5" Hose Cap Washer Rubber Upper Stem Stl. & Bronze Standpipe Cast Iron A 1 Valve Plate Cast Iron A 2 O-Ring Rubber Valve Rubber Rubber Seat Ring Bronze Throttling Ring Bronze A 2 Thrust Washer Teflon A 1 Snap Ring Stainless A 1 Lower Stem Mang. Bronze Stem Wedge Polycarbonate Stem Wedge Screw Bronze Lock Nut Bronze Drain Spool Bronze Drain Lever Bronze Lever Pin Bronze Clevis & Nut Bronze Drain Support Cast Iron Drain Rod Steel Drain Valve Backer Bronze Drain Valve Rubber Rubber Drain Cup Bronze Retaining Nut Bronze ** Bottom B & N Steel Bottom Gasket Accopac Bottom Cast Iron A 1 Stem Nut Clip Stainless B 1 Bottom Nut O.L. Bronze B 1 Bottom Nut O.R. Bronze Stem Coupling Steel Tubing Stem Coupling Pin Stainless Middle Stem Steel * Not Shown ** Quantity As Required NOTE: When ordering hydrant parts please specify the direction of opening (open left or open right) and the valve opening size (4¼", 4½" or 5¼"). D-17

21 D-18 Clow Medallion Fire Protection The Clow Medallion hydrant is designed and built to provide unsurpassed fire protection. Utilizing computer developed data, Clow engineers painstakingly sculpted interior surfaces to provide the smoothest possible waterway, resulting in the lowest possible loss of head through the hydrant. The result? More water to the nozzles faster. With the Clow Medallion, it s performance that counts. Maintenance While providing fire protection is a hydrant s primary function, ease of maintenance and repair are valid concerns of maintenance crews. Extraordinary steps were taken to insure that the Clow Medallion can be routinely serviced and repaired easily. All working parts are readily accessible from the top of the hydrant. 5-Year Limited Warranty The Medallion equals or exceeds the requirements of the American Water Works Association (AWWA). Also it has been listed by the Underwriters Laboratory (UL) and is approved by Factory Mutual (FM). Structurally and operationally this is clearly a superior Fire Hydrant. It s easy to see why it carries a full 5-year limited warranty on materials and workmanship. Specifications: Fire Hydrant shall be manufactured in accordance with AWWA C-502, be listed by Underwriters Laboratories, Inc. and have Factory Mutual Research approval. Fire Hydrant shall be designed for 250 psi working pressure and tested to 500 psi hydrostatic pressure. Fire Hydrant shall be dry-top center stem construction having an O -Ring sealed lubrication reservoir. Fire Hydrant shall be backed by manufacturer s 5-year limited warranty. Fire Hydrant shall be manufactured with operating nut and thrust nut made of bronze, with bearings located both above and below the thrust collar and with operating nut protected by a cast iron weather shield. Fire Hydrant shall be manufactured with nozzles mechanically locked into the barrel and having O - Ring pressure seals. Fire Hydrant shall be a Traffic Model, complete with safety flanges and steel stem coupling. Nozzle section must rotate 360 degrees. Fire Hydrant shall be manufactured with a main valve seat ring of bronze threaded into a bronze drain ring. A 360 degree drain channel shall have a minimum of two drain outlets. Fire Hydrant shall have a bronze upper valve plate and two urethane rubber facings that activate the drain ports. Fire Hydrant shall be manufactured with a lower valve plate that bottoms out in the shoe for maximum opening. Fire Hydrant shall be manufactured with a minimum main valve opening of 4½" or 5¼". Fire Hydrant shall be the Clow Medallion as manufactured by the Clow Valve Company or approved equal. D-18 Phone: 800-EJP-24HR ( ) Fax:

22 D-19 Clow Medallion D Clow Medallion Features 1. Moisture Protection: Durable cast iron weather cap combines with one piece bronze operating nut and "O"-rings to ensure reliable corrosion-free operation under all weather conditions Lubrication Reservoir: "O"-ring seals keep the oil in and water out. Reservoir may be filled easily without disassembly. 3. Computer Designed Contours: All interior components were individually designed to provide the lowest possible head-loss, which means more water, faster Safety Stem Coupling System: Breakaway parts shear cleanly below the top of the barrel, preventing nozzle section damage or opening of the main valve. 5. Bronze to Bronze: Bronze seat ring threads into bronze drain ring for corrosion-free protection Bronze Upper Valve Plate: Computer contoured shape means less turbulence smoother flow Compression Seating: High durometer rubber valve closes with the water pressure for a positive seal. 8. Anti-Friction: Thrust bearings above and below the bronze thrust collar provide low-torque operation even at 250 psi working pressure Bonnet Seals: Standard "O"-rings secure mating flanges and sealing throughout the Medallion. All "O"- rings are dependable and easy to replace. 10. Bronze Nozzles: Corrosion-resistant, field-replaceable bronze nozzles have "O"-ring seals for watertight connections. 11. Nuts & Bolts: Are stainless steel for long life Drain Valve: Rubber valve facing provides tight, long life seal. Bronze seat ring has 360 drain channel. Double ports flush with each use. 13. Ductile Iron Hydrant Shoe: Epoxy coated inside and out and shaped for low turbulence and maximum flow, the shoe is offered in a variety of end connections Lower Valve Plate: Bottoms out in the bottom of the strengthened shoe. Prevents valve from falling below seat ring. 15. Pads: Pads on hydrant shoe give large surface areas for standing and blocking hydrant D-19

23 D-20 Clow Medallion Ordering Information: Quantity of hydrants, accessories and maintenance kits required Size of main valve opening: 4½" or 5¼" Size and of hose nozzles Size and of steamer nozzles Hose and pumper nozzle thread specifications Type of inlet connection Depth of trench or bury Direction of opening Size and shape of operating nut, weather shield and cap nuts Color desired Town or municipality where hydrants will be installed, if possible bury dir. to Open hydrant w/drain hydrant l/drain 4' 6" OL ND 5' 0" OL ND 5' 6" OL ND 6' 0" OL ND 6' 6" OL ND 7' 0" OL ND 4' 6" OR ND 5' 0" OR ND 5' 6" OR ND 6' 0" OR ND 6' 6" OR ND 7' 0" OR ND Medallion Kits description 5¼" Medallion Main Valve Repair Kit ¼" Medallion Safety Repair Kit Medallion Top Extensions description 5¼" x 6" Medallion Hyd. Extension ¼" x 12" Medallion Hyd. Extension ¼" x 18" Medallion Hyd. Extension ¼" x 24" Medallion Hyd. Extension D-20 Phone: 800-EJP-24HR ( ) Fax:

24 D-21 Clow Medallion D Clow Medallion Parts ref. no. qty description material 1 1 Operating Nut O-Ring NBR Operating Nut Thrust Bearing Delrin Operating Nut O.R. Bronze Operating Nut O.L. Bronze Upper Stem Jam Nut SS Upper Stem Sleeve Bronze Upper Stem Sleeve O-Ring NBR Upper Stem O.R. CRS Upper Stem O.L. CRS Upper Stem Pin SS Safety Coupling Cotter Pins SS Safety Stem Coupling ST Safety Coupling Pins SS Lower Stem CRS Lower Stem Pin SS Upper Valve Plate O-Ring NBR Drain Valve Facing Screw SS Drain Valve Facing UR Upper Valve Plate Bronze Seat Ring Upper O-Ring NBR Seat Ring Bronze Seat Ring Lower O-Ring NBR Main Valve Rubber UR Lower Valve Plate Lockwasher SS Lower Valve Plate Bronze Weather Cap Hold Down Screw ZPS Weather Cap CI Thrust Nut Bronze Thrust Nut O-Ring NBR Bonnet Bolts & Nuts ZPS Bonnet CI Stem O-Rings NBR Bonnet O-Ring NBR Nozzle Section CI Pumper Nozzle Lock SS Pumper Nozzle O-Ring NBR Pumper Nozzle Bronze Pumper Nozzle Gasket Rubber Pumper Nozzle Cap CI Hose Nozzle Lock SS Hose Nozzle O-Ring NBR Hose Nozzle Bronze Hose Nozzle Gasket Rubber Hose Nozzle Cap CI Chain ZPS Trench Depth Tag & S-Hook AZPS Safety Flange Bolts & Nuts ZPS Safety Flange O-Ring NBR Barrel Upper Flange CI Safety Flange CI Barrel DI Shoe Bolts & Nuts SS Barrel Lower Flange CI Drain Ring O-Rings NBR Drain Ring Bronze Locking Spacer Steel Shoe CI Thrust Nut Set Screw SS Material Legend: CI...Cast Iron DI...Ductile Iron NBR...Nirtrile Butadiene Rubber SS...Stainless Steel Brz...Bronze CRS...Corrosion Resistant Steel Rbr...Rubber ST...Steel Tubing UR... Urethane Rubber Stl...Steel AZPS...Aluminum & Zinc Plated Steel ZPS...Zinc Plated Steel D-21

25 D-22 Post Hydrant The Eclipse #2 Post Hydrant Features: Comes with either one or two nozzles of the size you 1. select Interior parts can be replaced without disturbing any connections by unbolting the top cap and withdrawing the inside working parts. 3. Available in any depth of bury. 4. All hydrants come with ductile iron barrels for strength and corrosion resistance for longer life. 5. Has " valve opening. 6. Inlet can be 2", 2½" or 3" iron pipe thread. Also available with 2" or 3" mechanical joint inlet Self-draining feature prevents barrel freezing. 4 Handwheel Option Tamper Proof Option 5 6 #2 Post Hydrants have many features comparable to full size AWWA hydrants 7 NOTE: Post Hydrants are available in a wide variety of sizes and styles. Post Hydrants are non-stock and are ordered as needed. Please call your local Team EJP sales office for more information or assistance in ordering. D-22 Phone: 800-EJP-24HR ( ) Fax:

26 D-23 2" Blow Off Hydrant D The MainGuard Model #77 2" Blow Off Hydrant 3 1 Features: 1. 2½" NST Nozzle Also available in smaller sizes. 2. Traffic Break Away The MainGuard is designed to break easily at ground level. 3. Security A locking cover prevents water theft and protects MainGuard from the elements. 4. Easy Repair Just remove two bolts and take the inner workings out for easy repair and replacement. 5. Brass Working Parts All the moving parts are enclosed and made from high quality brass for greater durability and wear. 6. Full Draining Capabilities The MainGuard drains to prevent freezing after flushing. 7. 2" Female Iron Pipe Inlet description bury 6 #77 MainGuard Blow-Off Hyd. 6' 0" #77 MainGuard Blow-Off Hyd. 5' 6" The MainGuard Model #78 Blow Off Hydrant The Model #78 has the same features as the Model #77 Blow Off hydrant except that it is designed for underground installations. The Model #78 can be placed in a meter box pit for easy access. NOTE: MainGuard Blow Off hydrants are available on a custom order basis only. Please call your local Team EJP sales office for more information or assistance in ordering. D-23

27 D-24 Sampling Station Eclipse No. 88 Sampling Station 1 Features: 1. All interior parts can be replaced without disturbing connections by unbolting the top cap and withdrawing the inside working parts. 2. ¾" hose connection or unthreaded brass nozzle to allow for easy flaming for disinfection. 3. Aluminum weathershield with handy interior shelving for supplies and storage Vent tube with open/close valve. 5. Brass interior pipe isolates water flow and maintains consistency of brass interior parts, insuring maximum sample quality. Galvanized riser pipe for exterior protection. Brass valve body with ¾" FIP inlet. 3 6 Specifications: Sampling Stations shall be (specify) bury, with a ¾" FIP inlet, and a ¾" hose or unthreaded nozzle. All stations shall be enclosed in a lockable, non-removable, aluminum-cast housing. When opened, the station shall require no key for operation, and the water will flow in an all-brass waterway. All working parts will also be of brass and be removable from above ground with no digging. A copper vent tube will enable each station to be pumped free of standing water to prevent freezing and to minimize bacteria growth. The exterior piping will be galvanized. Sampling Stations shall be as manufactured by Kupferle Foundry, St. Louis, MO. NOTE: Sampling Stations are non-stock items. Please call your local Team EJP sales office to order or for more information. 5 ¼" Vent Tube used to pump water from barrel Standard utility bilge pump attaches to vent tube to remove water from waterway, insuring a clean sample in the future, and preventing freezing. 7 D-24 Phone: 800-EJP-24HR ( ) Fax:

28 D-25 Hydrant Markers & Accessories D Hydrant Markers & Tags markers: Double dipped in Safety Orange color paint 2 reflective, weatherproof stickers are supplied so hydrants can be easily located at night Standard rods are ½" with ½ loop for easy installation Large 4½" round flag reduces chance of injury Individually wrapped and packed 10 to a bundle Galvanized Spring Flags W/Reflective Bands Close-up of Spring with washer Tags: Galvanized attaching cable with duplex clips Unbreakable tempered virgin nylon Numbered or lettered both sides; 3 characters standard; 4 characters available for an additional charge 8 vivid color combinations Crimping tool available description Hydrant Tag Crimping Tool 48" Hydrant Marker 3 8" Galvanized " Hydrant Marker ½" Rebar " Hydrant Marker 3 8" Galvanized Hydrant Tag w/cable & Clip Hydrant Tag Crimping Tool Spring-loaded Hydrant Markers are made of one piece galvanized spring steel for corrosion resistance. The mounting bracket is part of the spring; a washer is supplied. Four 6" reflective weatherproof bands are applied (two red and two white) to the top section of the marker for superior visibility. description 4' Galv. Spring Flag w/reflective Bands ' Galv. Spring Flag w/reflective Bands ' Galv. Spring Flag w/bands 4" x 5" Flag " x 5" Replacement Flag Shown mounted on 3 8" rod Orange Fire Hydt. Sign 7" O.D. 3.25" I.D A Universal Flag Kit (Lexan) 4½" Disc w/center Mounted U-Clip & SS Set Screw Fits ¼" to ½" Shaft 05819A D-25

29 D-26 Hydrant & Waterworks Tools Hydrant Setter* The hydrant setter greatly eases the installation of hydrants which can weight as much as a half ton. The lifting rings, which are held in proper alignment by the spreader bar, fit over the 2½" hose nozzles and are locked in place by the hose nozzle caps. Adjustable Hydrant Wrench This hydrant wrench is adjustable to fit up to 1¾" pentagon operating nuts and pumper or steamer caps. The handle is knurled for a better grip. description Adjustable Hydrant Wrench - Zinc Coated description Hydrant Setter with Spreader Bar * Hydrant Setters are pull-tested, certified and tagged with capacity. D-26 Phone: 800-EJP-24HR ( ) Fax:

30 D-27 Hydrant Storz Connections D Integral Hydrant Storz The integral hydrant storz nozzle is provided on new hydrants. A storz spanner wrench is required for cap removal. The storz meets or exceeds the requirements of AWWA C502 regarding material and pressure testing. The storz shall have a brass metal face and hard anodized aluminum storz ramps and lugs. The aluminum finish shall be hard coat anodized to Mil-A-8625, Type 3, dark gray. The storz shall be made of forged or extruded 6061-T6 aluminum. The blind cap shall have hard anodized aluminum storz ramps and lugs, made of forged or extruded T6 aluminum. The cap shall be equipped with a suction seal. The cap shall be connected to the hydrant with a 0.125" vinyl coated aircraft cable. Once installed, the integral hydrant storz with cap extends less than 2" from the hydrant nozzle. Permanent Hydrant Storz The permanent hydrant storz threads onto the male nozzle and is secured permanently to the hydrant. A storz spanner wrench is required for cap removal. The storz adapter shall have a hard anodized aluminum metal face seal and hard anodized aluminum storz ramps and lugs. The adapter finish shall be hard coat anodized to Mil-A-8625, Type 3, dark gray. The adapter shall be made of forged or extruded 6061-T- aluminum and secured to the nozzle by (2) stainless steel screws, inserted 180 degrees apart. The female adapter shall contain a flat rubber gasket which seals against the male hydrant nozzle. The blind cap shall have hard anodized aluminum storz ramps and lugs, made of forged or extruded T6061-T6 aluminum. The cap shall be equipped with a suction seal. The cap shall be connected to the adapter or hydrant with a 0.125" vinyl coated aircraft cable. Once installed, the permanent hydrant adapter with cap extends less that 3" from the hydrant nozzle. NOTE: For more information please contact your local EJP sales representative. D-27

31 D-28 Captivater Hydrant Lock The Captivater Locking Fire Hydrant Cap The Captivater prevents unauthorized hydrant use, eliminates water theft and waste, reduces hydrant vandalism and lowers operation costs. Its universal design fits EVERY hydrant from EVERY manufacturer, regardless of year or model. Features: The Captivater is the perfect Homeland Security solution: The Captivater fits any make, model or year of hydrant in minutes without modification. Provides a safe and easy method to secure fire hydrants. Easily installed in minutes without special tools. Sealed for protection from the elements, the Captivater withstands weather and long-term use as well as or better than original caps. All Captivater wrenches are serial ed, allowing hydrant access to be controlled. The Captivater s appearance is the same as a standard hydrant cap. What Does This Mean? Your hydrants are secured from unauthorized use, so children and vandals (or people with more sinister plans) cannot gain access to your water system. Benefits: The Captivater solves security and safety issues. It eliminates water theft from hydrants. It ensures the availability of water-dependent services. Reduces operation costs; revenue loss from open hydrants will be a thing of the past. The Captivater helps conserve your water supply and by saving water, you save money! description Captivater Hydrant Lock Cap (Pumper Captivater Hydrant Lock Cap (Hose) NOTE: For more information please contact your local EJP sales representative. Captivater Hydrant Lock Wrench description Captivater Hydrant Lock Wrench* * To insure security all wrenches are shipped direct to the customer from the factory. D-28 Phone: 800-EJP-24HR ( ) Fax:

32 Waterous Classic Pacer THE RIGHT WAY The Waterous Classic Pacer by AMERICAN Flow Control merges a classic look with all the traditional features of the standard Pacer design. Classic look with the standard contemporary Pacer design features Complete parts interchangeability with the contemporary Pacer Ductile iron nozzle section, standpipes and base Available through your local AMERICAN Flow Control distributor Two-part catalyzed epoxy primer and polyurethane coating system above grade 250 psig rated working pressure Shown with optional Storz pumper nozzle AMERICAN Flow Control P.O. Box 2727 Birmingham, AL Phone: Fax: afcsales@american-usa.com Waterous Company 125 Hardman Avenue South South St. Paul, MN Phone: Fax: afcsales@american-usa.com Version

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT WATEROUS FIRE HYDRANT DUCTILE IRON 250 P.S.I.G. WATEROUS FIRE HYDRANT AMERICAN FLOW CONTROL It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT CONSTRUCTION WATEROUS FIRE HYDRANT TWO PIECE OPERATING

More information

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY clowvalve.com MEDALLION HYDRANT AWWA C50 UL LISTED FM APPROVED NSF 6/37 CERTIFIED 50 PSI WORKING PRESSURE 0-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane, Inc. MEDALLION HYDRANT FIRE PROTECTION

More information

ADMIRAL HYDRANT. clowvalve.com

ADMIRAL HYDRANT. clowvalve.com clowvalve.com ADMIRAL HYDRANT AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 350 PSI WORKING PRESSURE AVAILABLE 10-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane,

More information

American Flow control 5 1/4 b-84-b-5

American Flow control 5 1/4 b-84-b-5 American Flow control 5 1/4 b-84-b-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING

More information

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories Inc. and Approved by FM Approvals in applicable

More information

GENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.

More information

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H

More information

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. DUCTILE IRON

More information

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories, Inc. and Approved by FM Approvals in applicable configurations.

More information

American Flow control 5 1/4 B-62-B-5

American Flow control 5 1/4 B-62-B-5 American Flow control 5 1/4 B-62-B-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING

More information

September 2012 / M&H C502 / Model 129

September 2012 / M&H C502 / Model 129 GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line

More information

AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT

AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. ONE-PIECE BRONZE

More information

5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL

5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL 5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and FM Approved in applicable configurations. ONE-PIECE

More information

Mueller Super Centurion 250 Fire Hydrant

Mueller Super Centurion 250 Fire Hydrant Mueller Super Centurion 250 Fire Hydrant Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion 250 Fire Hydrant...250 psig rating, high flow, dependable performance,

More information

Water Distribution Solutions

Water Distribution Solutions Water Distribution Solutions Table of Contents WaterMaster 5CD250 Fire Hydrants 6 WaterMaster 5BR250 Fire Hydrants 8 FlowMaster Resilient Wedge Gate Valves 11 Valve Boxes 17 Meter Boxes 22 Table of Contents

More information

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H

More information

Water Distribution Solutions

Water Distribution Solutions Water Distribution Solutions Table of Contents WaterMaster 5CD250 Fire Hydrants 6 WaterMaster 5BR250 Fire Hydrants 8 FlowMaster Resilient Wedge Gate Valves 11 Valve Boxes 17 Meter Boxes 22 Table of Contents

More information

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION TESTING AND DESIGN SPECIFICATIONS (PER AWWA C502 / NSF /ULC & FM) 1. Hydrant shall be manufactured in accordance with AWWA C502 latest revision

More information

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R

More information

2-6 FIRE HYDRANT---(MODEL ½ & 5 ¼

2-6 FIRE HYDRANT---(MODEL ½ & 5 ¼ M&H PDF PAGE INDEX Page PRODUCT 2-6 FIRE HYDRANT---(MODEL 129 4 ½ & 5 ¼ ) 7 How to Order Fire Hydrants 8 FIRE HYDRANT WARRANTY 9-13 FIRE HYDRANT---(MODEL 929 5 ¼ ) 14-18 FIRE HYDRANT---(POST HYDRANT 2

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS SUPER CENTURION FIRE HYDRANT Mueller Super Centurion Fire Hydrant Since its introduction in 1976, millions of Centurion fire hydrants have been installed throughout North America. There are a number of

More information

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement. Sentinel 250 Fire Hydrant Solid design and features to meet any municipal requirement. Product Features That meet any municipal requirement. 1 Operating Nut Shields the hold down nut from tampering and

More information

MUELLER Super Centurion fire hydrants

MUELLER Super Centurion fire hydrants MUELLER Super Centurion fire hydrants MUELLER SUPER CENTURION FIRE HYDRANT Since its introduction in 1976, millions of Centurion fire hydrants have been installed throughout the world. There are a number

More information

INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT

INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT PAGE INTRODUCTION AND HISTORY............................................................. 2B 2 ORDERING Dimensions: Overall Hydrant...............................................................

More information

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-DD FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J K M L N P Q S R

More information

Trend Hydrants. Installation, Operation, Maintenance and Overhaul Instructions. Table of Contents. Illustrations. Tables H /16/10 12/04/95

Trend Hydrants. Installation, Operation, Maintenance and Overhaul Instructions. Table of Contents. Illustrations. Tables H /16/10 12/04/95 Installation, Operation, Maintenance and Overhaul Instructions Form No. H-351 Date 12/04/95 Revision Date 02/16/10 Trend Hydrants New Style Trend Old Style Trend Model WB77 Wet Top Model WT77 Dry Top Model

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation

More information

VALVE AND HYDRANT PRICE BOOK

VALVE AND HYDRANT PRICE BOOK VALVE AND HYDRANT PRICE BOOK HTTP://WWW.CLOWVALVE.COM EFFECTIVE DATE February 10, 2012 CLOW VALVE COMPANY 902 SOUTH SECOND ST. OSKALOOSA, IA 52577 PH# 800-829-2569 FAX# 641-673-8269 CLOW VALVE COMPANY

More information

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating

More information

MUELLER Hydrant Security Device

MUELLER Hydrant Security Device MUELLER HYDRANT DEFENDER SECURITY DEVICE 9A. Rev. 8-04 When conducting a vulnerability assessment (V.A.), infiltration of a municipal water supply through an unsecured fire hydrant should be a primary

More information

Sentinel 250 Fire Hydrant

Sentinel 250 Fire Hydrant Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service

More information

Data Sheet Issue A

Data Sheet Issue A General Description The Rapidrop Fig 601/602 dry barrel post / flushing fire hydrant is designed to be a trouble free, easy to maintain hydrant. The Fig 601/602 fire hydrant is rated for a working pressure

More information

SECTION 8 Fire Protection

SECTION 8 Fire Protection Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.

More information

INDEX WATEROUS 5-1/4 IN. PACER FIRE HYDRANT

INDEX WATEROUS 5-1/4 IN. PACER FIRE HYDRANT INDEX WATEROUS 5-1/4 IN. PACER FIRE HYDRANT PAGE INTRODUCTION AND HISTORY.............................................................. 2B-2 ORDERING Dimensions: Overall Hydrant...............................................................

More information

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS Date Printed: November 2010 FIRE HYDRANTS or Tyton (6"),6, or 8" A EDDY FIRE HYDRANTS PARTS LIST WORKING PRESSURE: 150 PSI Note: Discontinued For Reference Only 350 PSI Working Pressure

More information

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3 SECTION VIII (Sub-section 430) Wastewater Valves and Appurtenances Article Page 1. General 430-1 thru 430-2 2. Gate Valves 430-2 thru 430-3 3. Plug Valves 430-3 thru 430-4 4. Check Valves 430-4 5. Tapping

More information

Harlingen Water Works System Approved Products List For Subdivisions. January 11, 2005

Harlingen Water Works System Approved Products List For Subdivisions. January 11, 2005 Harlingen Water Works System Approved Products List For Subdivisions January 11, 2005 Revised March 24, 2016 Harlingen Water Works System Approved Products List for Subdivisions Table of Contents: 1. Valves

More information

AVK SAUDI VALVES MANUFACTURING COMPANY

AVK SAUDI VALVES MANUFACTURING COMPANY AVK SAUDI VALVES MANUFACTURING COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION

More information

Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability

Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion Fire Hydrants High flow and dependable long time performance. 1 Hold-down nut Features

More information

SWING CHECK VALVES SERIES 52-SC SERIES 600

SWING CHECK VALVES SERIES 52-SC SERIES 600 SWING CHECK VALVES SERIES 52-SC SERIES 600 FEATURES/BENEFITS/SPECIFICATIONS AMERICAN Flow Control Series 52-SC Swing Check Valves incorporate design features to help increase service life for water and

More information

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending

More information

PRODUCT MANUAL 5-1/4 WATEROUS PACER FIRE HYDRANT

PRODUCT MANUAL 5-1/4 WATEROUS PACER FIRE HYDRANT PRODUCT MANUAL 5-1/4 WATEROUS PACER FIRE HYDRANT INDEX 5-1/4 WATEROUS PACER FIRE HYDRANT Page INTRODUCTION AND HISTORY... 2B-2 ORDERING Dimensions: Overall Hydrant... 2B-3 Optional Bottoms (Bases)... 2B-4

More information

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,

More information

Rev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A.

Rev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A. Rev. 2/16 MUELLER Fire Hydrant Reference Manual 2016 Mueller Co. Printed in the U.S.A. Index 1 Fire Hydrant Reference Material Index Index...1 Identification...2-36 Dry Barrel Hydrants - AWWA...3-21 Dry

More information

Approved Branded Traceable Fire Protection & Waterworks Valves

Approved Branded Traceable Fire Protection & Waterworks Valves Approved Branded Traceable Fire Protection & Waterworks Valves (800) 766-0076 www.smithcooper.com Los Angeles, CA Atlanta, GA Vancouver, WA Chicago, IL AWWA C515 Compliant CONSIDER Your Options Tamper

More information

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved Worldwide Contacts www.tyco-fire.com Model TJP Resilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator General Description TYCO Model TJP Resilient-Seated Gate Valves with Vertical and

More information

KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES

KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES KENNEDY VALVE AWWA C515 Resilient Wedge Gate Valves Meet or Exceed the Requirements of AWWA Standard C515 UL-262/FM-1120/1130 ULC-Underwriters of Canada 2 1/2

More information

Slide Gate Hydrant Maintenance Manual

Slide Gate Hydrant Maintenance Manual Slide Gate Maintenance Manual Terminal City Iron Wks Ltd. Unit#3 99 19th Street, Langley, BC V1M 3C This Maintenance Manual is intended to give a guide to Maintenance. The Manual covers: Maintenance and

More information

Suggested Specifications

Suggested Specifications ISO 9001 Certified Suggested Specifications The Milliken criteria of quality, reliability, safety and value are embodied in the Millcentric Eccentric valve, setting higher standards for dependable performance

More information

PIPE OUTSIDE DIAMETER GUIDE

PIPE OUTSIDE DIAMETER GUIDE June 7, 2018-1 PIPE OUTSIDE DIAMETER GUIDE PIPE OUTSIDE DIAMETER GUIDE - SMALL DIAMETER PIPE SIZES NOMINAL PIPE SIZES 1 /2" 3 /4" 1" 1 1 /4" 1 1 /2" 2" 2 1 /2" THIS O.D. GUIDE IS FOR YOUR CONVENIENCE &

More information

VALVES, FIRE HYDRANTS, AND APPURTENANCES

VALVES, FIRE HYDRANTS, AND APPURTENANCES VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems. SECTION 210500 - COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS A. Section 099000

More information

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE ISO 9001 CERTIFIED MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE Suggested Specifications The Milliken criteria of quality, reliability, safety and value are embodied in the Millcentric Eccentric valve,

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN - DARLING B-84-B-5 FIRE HYDRANT INTRODUCTION AND HISTORY... 1B-2 ORDERING Dimensions: Overall Hydrant... 1B-3 Optional Bases...1B-4

More information

Valve Selection. 1. Function and service considerations

Valve Selection. 1. Function and service considerations 1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.

More information

FIRE HYDRANTS. Wet Barrel Fire Hydrants

FIRE HYDRANTS. Wet Barrel Fire Hydrants FIRE HYDRANTS Wet Barrel Fire Hydrants Jones Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company is the innovator in the

More information

Series 800 AWWA Butterfly Valves

Series 800 AWWA Butterfly Valves Series 800 AWWA Butterfly Valves Valve and Gate Group A Century of Experience GA valves are known for long term reliability in the most demanding water and wastewater applications. Whether a simple check

More information

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND

More information

AWWA Swing Check Valves

AWWA Swing Check Valves AWWA Swing Check Valves Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the

More information

ECCENTRIC PLUG VALVES

ECCENTRIC PLUG VALVES Serving the Water & Waste Water Industry Since 1878 ECCENTRIC PLUG VALVES C517 3 24 sizes available Multiple end connections available M&H Valve is a division of McWane, Inc. www.mh-valve.com AVAILABLE

More information

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901 CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the Henry

More information

Available End Connections & Size Range

Available End Connections & Size Range ECCENTRIC PLUG VALVES Size Range 3"-24" Water Working Hydrostatic Size Range Pressure psi Test psi 3"-12" 175 350 14"-24" 150 300 Available End Connections & Size Range Figure No. Flanged 3"-24" F-5412

More information

BUTTERFLY VALVES KENNEDY 140 YEARS AWWA C504 CLASS 150B & 250B CERTIFICATIONS ISO 9001 ISO BS OHSAS

BUTTERFLY VALVES KENNEDY 140 YEARS AWWA C504 CLASS 150B & 250B CERTIFICATIONS ISO 9001 ISO BS OHSAS KENNEDY BUTTERFLY S CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C504 CLASS 150B & 250B STYLE 4500 3-24 STYLE 1450 30-54 CONSULT KENNEDY FOR SIZES LARGER THAN 54 INCHES. 140 YEARS WWW.KENNEDY.COM

More information

INSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS.

INSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS. MADE IN U.S.A. Valve insertion, simplified 10-12 installations in cast iron, ductile iron, A/C, PVC C-900 and steel pipe No Loss of Pressure Minimal Water Loss Completion time is less than 2 hours Much

More information

InsertaValve Sleeve. InsertaValve Valve Assembly. Valve Insertion, simplified. Material Specifications. Transmate InsertaValve

InsertaValve Sleeve. InsertaValve Valve Assembly. Valve Insertion, simplified. Material Specifications. Transmate InsertaValve Material Specifications Material Specifications Sleeve 10" - 12" installations in cast iron, ductile iron, A/C, PVC C-900 and steel pipe No Loss of Pressure Minimal Water Loss Completion time is less than

More information

According to AWWA-standard

According to AWWA-standard According to -standard Water Fire fighting - UL/FM 304 Gate valves - Cast iron 320 Gate valves OS&Y 306 Service connection valves 322 Post indicators 306 Combi valves 307 Gate valves - 310 Gate valves

More information

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND STORAGE INSTALLATION

More information

American Flow control Series 2500

American Flow control Series 2500 American Flow control 14-66 Series 2500 Resilient wedge gate valve FLOW CONTROL Construction Ductile iron operating nut Provides strength and durability. Lifting DEVICES 14-66 Valve is constructed of high-strength

More information

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2 3 4 4 1 /2 5 6 AC728: Male ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS VALVES DOUBLE SWIVEL FEMALE......for adapting from male to female. Made from extruded lightweight aluminum alloy, then hardcoated to resist

More information

of wet barrel hydrants, hydrant valves and hydrant tools.

of wet barrel hydrants, hydrant valves and hydrant tools. JONES WET BARREL FIRE HYDRANTS The most complete selection of wet barrel hydrants, hydrant valves and hydrant tools. Bronze wet barrel fire hydrants Jones is the leader. With over 100 years of experience

More information

BS 5163 Resilient Wedge Gate Valve

BS 5163 Resilient Wedge Gate Valve BS 516 Resilient Wedge Gate Valve BS 516 Flanged Resilient OS&Y Gate Valve, Type A, (XZ41X), /16, Gate valves serve to cut the medium flow in the piping system, widely used in the field of potable water,

More information

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL PACKAGE CONTENT 1. Reason for Change 2. Features and Benefits Provided 3. Specification Text 4. Specification Diagram JUSTIFICATION FOR FIRE HYDRANT SPECIFICATION

More information

SECTION 1019 VALVES AND APPURTENANCES GENERAL: Valves shall have manufacturer's name and pressure rating cast in raised letters.

SECTION 1019 VALVES AND APPURTENANCES GENERAL: Valves shall have manufacturer's name and pressure rating cast in raised letters. SECTION 1019 VALVES AND APPURTENANCES Delete this Section in its entirety and replace with the following: SECTION 1019 VALVES AND APPURTENANCES 1019-1 GENERAL: Valves shall have manufacturer's name and

More information

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING

More information

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901 AWWA SWING CHECK VALVES Engineering Creative Solutions for Fluid Systems Since 1901 TABLE OF CONTENTS AWWA SWING CHECK VALVE Series 8001 Lever & Weight or Spring...1 Series 9001 Lever & Weight or Spring...2

More information

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Kunkle Models 91/218/228 liquid relief valves Safety and relief products Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 228 Features Bolted bonnet allows easy inspection and servicing without removal from

More information

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Kunkle Models 91/218/228 liquid relief valves Safety and relief products Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 8 Features Bolted bonnet allows easy inspection and servicing without removal from

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230523 GENERAL DUTY VALVES FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. The following

More information

Ford Brass Saddles Style 101B and 202B

Ford Brass Saddles Style 101B and 202B 101B Ford Brass Saddles 101B and 202B 101B, 3/4" and 1" Taps 202B, 3/4" through 2" Taps Specifications Body - 85-5-5-5 brass alloy as per ASTM B62, ASTM B584 and AW WA C800. Threads may be FIP, AW WA,

More information

K81 Guardian Fire Hydrants. Operation & Maintenance Guide

K81 Guardian Fire Hydrants. Operation & Maintenance Guide Kennedy Valve K81 Guardian Fire Hydrants Operation & Maintenance Guide Installation 1. When hydrants are received from manufacturer they should be handled carefully to avoid breakage and damage to flanges.

More information

INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW

INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW PATENT #US 9,541,218 NIBCO Series NIP-2AW Wall Mount Indicator Posts are designed and manufactured to: Operate

More information

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve

More information

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve

More information

Lineseal Butterfly Valves 150B, 250B, & 350B Class; Sizes 3-48

Lineseal Butterfly Valves 150B, 250B, & 350B Class; Sizes 3-48 Lineseal Butterfly Valves 0B, 0B, & 0B Class; Sizes -8 Mueller Lineseal Butterfly Valves Sizes -8 Performance is key. Designed specifically for the waterworks industry, Lineseal butterfly valves offer

More information

Index. Butterfly Valves

Index. Butterfly Valves Dry Bulk - Chemical - Petroleum Dry Bulk - Chemical - Petroleum Nozzles Nozzles & Valves & Index Index Part No. Description Page Nozzles P- 202 Overwing Aircraft Refueling, Bronze 1 P- 2022 Overwing Aircraft

More information

SECTION VALVES AND OPERATORS

SECTION VALVES AND OPERATORS SECTION 15200 VALVES AND OPERATORS PART 1 - GENERAL 1.1 SUBMITTALS A. Shop Drawings: 1. Product data sheets for make and model. 2. Complete catalog information, descriptive literature, specifications,

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE PRESSURE REDUCING CONTROL VALVE 06/08 Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) X P/L Standard Components 1 Main

More information

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE INDEX SERIES 2500 DUCTILE IRON RESILIENT WEDGE GATE VALVE OPERATION and MAINTENANCE MANUAL. OPERATION AND MAINTENANCE Operation,

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SUNY GENESEO 220523-1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 2700 - HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING

More information

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Closes quickly when downstream pressure exceeds reduced pressure setpoint 3 PRESSURE REDUCING VALVE with SURGE

More information

Pipe Size Pipe OD TwinSeal Hinged Design for IPS PVC Pipe MODEL 3402 BRONZE SADDLE FOR COPPER TUBING

Pipe Size Pipe OD TwinSeal Hinged Design for IPS PVC Pipe MODEL 3402 BRONZE SADDLE FOR COPPER TUBING MULTIPLIER SERVICE SADDLES MODEL 3401 BRONZE SADDLE FOR IPS PVC BODY CASTINGS: Waterworks Bronze (85-5-5-5) per ASTM B584 and AWWA C800. FASTENERS: Silicon Bronze per ASTM B98. GASKET: Patented SBR TwinSeal

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories. PRESSURE REDUCING CONTROL VALVE 02/09 Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) P/L Standard Components 1 Main Valve

More information

Ford Fabricated Steel Products

Ford Fabricated Steel Products Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas

More information

JEFFERSON UTILITIES 270 INDUSTRIAL BLVD. KEARNEYSVILLE, WV (304) STANDARDS AND SPECIFICATIONS

JEFFERSON UTILITIES 270 INDUSTRIAL BLVD. KEARNEYSVILLE, WV (304) STANDARDS AND SPECIFICATIONS JEFFERSON UTILITIES 270 INDUSTRIAL BLVD. KEARNEYSVILLE, WV 25430 (304) 728-2077 STANDARDS AND SPECIFICATIONS FEBRUARY 28, 2018 1 TABLE OF CONTENTS GENERAL MATERIAL... 3 WATER... 5 DUCTILE IRON PIPE...

More information

Ford Service Saddles and Tapping Sleeves

Ford Service Saddles and Tapping Sleeves Section AA 04/2013; web revision 02/2014 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171

More information

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section. SECTION 23 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Gate Valves 2. Balancing Valves 3. Ball Valves 4. Butterfly Valves 5. Swing Check Valves 1.2 RELATED SECTIONS A. Contents of Division

More information

SECTION 17 FIRE HYDRANT ASSEMBLIES General

SECTION 17 FIRE HYDRANT ASSEMBLIES General SECTION 17 FIRE HYDRANT ASSEMBLIES 17-1.01 Scope 17-1 General This section describes the requirements for furnishing and installing as appurtenances to treated water mains. These requirements include the

More information