TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Size: px
Start display at page:

Download "TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5"

Transcription

1 Reference. : TRHZ0630_R Date : v. 27, 202 Page.: of pplicant : ddress : HINING LOFTY XUN BNNER TEXTILE CO., LTD. NO.70-,LONGXING ROD, HICHNG STREET, HINING CITY, ZHEJING, CHIN. The following merchandise was (were) submitted and identified by the client as: Name Of Product : SILK SHINING FBRIC Test Model : LXDP-07 Model May Cover : Main material : 00% Polyester Color : White End Use : Banner show Sample Received : v. 3, 202 Test Period : v.3, 202 v. 20, 202 Test Request : s the Client required, to do the flammability requirements of the sample according to DIN 02 B(998) Test Method : DIN 02- (May 998) Fire behavior of building materials and elements Part : Classification of building materials, Requirements and testing Test Results : Please refer to next page(s). Conclusion : The tested sample meets the low flammability requirements of class B of building materials under DIN 02- (May 998). THIS REPORT IS TO SUPERSEDE TEST REPORT TRHZ0630. Issued by: TÜV NORD GPSC Manager

2 Reference. : TRHZ0630_R Date : v. 27, 202 Page.: 2 of TEST RESULTS: I. Test conducted This test was conducted as per DIN 02-:990, DIN 02-6:998 and DIN 02-:998 Clause 6.2. Classification in according to DIN 02- (May 998) Clause 6.-Class B materials II. Sample details General description Color Density Size of sample Polyester,27GSM White 2.6m*.7m Conditioning Prior to testing, the sample was conditioned at least days to constant mass at a temperature of 23 ± 2 C, and a relative humidity of 0 ± 6 %. III. Test results ) Brandschacht Test according to DIN 02- &6 Orientation: Product direction, Exposed surface: Face of the sample Results of Brandschacht Test (part ) Specimen fixings according to DIN 02 part, table Max. flame height above lower sample edge**; Time ) Meltingburning through 0 2: Time ) 0: Flamingglowing, Time ) Discolouring, Time ) Burning droplets Begin ) mount Specimen material falling off in separate droplets Specimen material falling off continuously 0:06 Test assemblies.

3 Reference. : TRHZ0630_R Date : v. 27, 202 Page.: 3 of Results of Brandschacht Test (part 2) Burning parts Begin ) Parts of sample falling off separately Parts of sample falling off continuously Duration of continued combustion on mesh base (max.) Burner material Time ) flame Premature ending of test End of burning at specimen impairment by drippingfalling 6 Time when test terminated (if applicable) Burning after end of test Duration Number of specimens Front of specimen Height of flame Glowing after end of test Duration Number of specimens Front of specimen Top half of specimen Bottom half of specimen ) ) :3 2: Test assemblies. ******** To be continued ********

4 Reference. : TRHZ0630_R Date : v. 27, 202 Page.: of Results of Brandschacht Test (part 3). Test assemblies. Residual length 28 Single results verage of the single results 0 Smoke temperature 30 Max. of average 0 3 Time ) 3.28 te: ) time from start of testing 2) rmal Flammability Test according to DIN 02- Clause 6.2 Flame application: bottom edge ignition Specimen. 2 3 Reaching the measuring mark within 20 seconds Self extinguishing of the flame (s) 6 6 Max. flame height () End of afterflaming (s) 6 End of afterglowing (s) Molten dripping Smoke developments (visual impression) Slight ll timings are from start of testing ******** To be continued ********

5 TEST REPORT Reference. : TRHZ0630_R Date : Jun. 2, 20 Page.: of Comments: DIN 02-B2 Criteria for classification for Class B (DIN 02- Clause 6..2) ll materials, except flooring, may be classed as B materials if they met, a) Pass DIN 02-6 brandschacht test if ) The mean value for the residual length of each specimen is at least, and no individual values are lower than 0 ; 2) The mean effluent temperature does not exceed 200 in any test; 3) The requirement for the residual length of each specimen is met even where there is afterflame, afterglow, or smouldering. b) Pass DIN 02- Clause Ignitability Test if, For each specimen, flaming doesn t reach the gage mark within 20s after flame application. STTEMENTS: This test report does not replace any mandatory certification of the product that may be required. The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire and smoke hazard of the product in use. SMPLE PHOTO TÜV NORD TRHZ0630_R ******** END OF REPORT *********

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5 Test Report AJHL1603002392FB Date: APR.06, 2016 Page 1 of 5 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)

More information

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH

More information

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO.KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S FRONTLIT 510

More information

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the

More information

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6 Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 1 of 6 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)

More information

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6 Test Report. AJHL1610011324FB-2 Date: OCT.24, 2016 Page 1 of 6 POSTER AND PANEL CPERE ANDORRA, SN, POL. IND, ILLA,SUD, NAUS, 4, 5, I6,08650, SALLENT, BARCELONA, SPAIN The following sample(s) was were submitted

More information

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report No. AJHL1606005818FB Date: JUN.21, 2016 Page 1 of 6 HAINING JINMAO WARP KNITTING CO., LTD NO. 38 LUHONG ROAD DINGQIAO TOWN HAINING CITY ZHEJIANG CHINA The following sample(s) was / were submitted

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2015-1661

More information

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd European B1 Fire Rating soft collection softwall + softblock Fire Retardant (FR) Treated textile products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2016-1390

More information

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7 Germany B1 Fire Rating kraft paper products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604 685 0342 info@molodesign.com www.molodesign.com molo kraft paper

More information

Test report No

Test report No Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2296 for applying

More information

Test report No

Test report No Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2211 for applying

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1940

More information

Test report no

Test report no Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2015-1339

More information

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( ) Test certificate Nr. 3666/4421-a -Fe/Wi- page 1 TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY

More information

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY MPA BRAUNSCHWEIG Inspection report nr (3329/2706)

More information

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3 Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 1 of 3 HONGGE (GUANGZHOU) PAPER CO., LTD BUILDING 1, HE TAI INDUSTRY ZONE, HE TAI ROAD NO.2, HE BIAN, JIA HE TOWN, BAI YUN DISTRICT, GUANGZHOU.

More information

FIRE TEST REPORT FH 5154

FIRE TEST REPORT FH 5154 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5154 CONE CALORIMETER TEST AND NCC SPECIFICATION C1.10

More information

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5728 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5728 CONE CALORIMETER TEST AND NZBC VERIFICATION METHOD

More information

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces UL 2043 TEST REPORT Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces Pipe Fixings TSMI TSMI Non-metallic Tubing Channel Clip for

More information

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

FIRE REGULATION IN FURNITURE WORLD OVERVIEW 6/8 FIRE REGULATION IN FURNITURE WORLD OVERVIEW For your internal use only http://www.crepim.com / 1 Since many years, comprehensive studies of the ignition hazard of upholstery and covering materials

More information

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5078 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5078 CONE CALORIMETER TEST AND NZBC ACCEPTABLE SOLUTIONS

More information

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA REPORT NUMBER: 101351744MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA TEST REPORT EVALUATION CENTER Intertek Verification Center 8431 Murphy Dr Middleton, WI 53562 x RENDERED TO Marc Doheny

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1031

More information

Test report no

Test report no Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2014-1452-2

More information

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT Textiles 1) Fibre composition - Qualitative analysis (Internal MK method) 2) Fibre composition - Binary fibre mixtures (EN ISO 1833-series) 3) Fibre composition - Ternary fibre mixtures (EN ISO 1833-2)

More information

The Furniture Retail Quality Group Best Practice Guide

The Furniture Retail Quality Group Best Practice Guide The Furniture Retail Quality Group Best Practice Guide Flammability Testing Best Practice Guide for ignition testing regarding the UK Furniture and Furnishings (Fire) (Safety) Regulations 1988 amended

More information

PRODUCT EVALUATION REPORT

PRODUCT EVALUATION REPORT SPUTO AND LAMMERT ENGINEERING, LLC STRUCTURAL ENGINEERS 10 SW 1 ST AVENUE, GAINESVILLE, FL 32601 PHONE: 352-378-0448 FAX: 352-373-1331 E-MAIL: sputoandlammert@mindspring.com PRODUCT EVALUATION REPORT MANUFACTURER:

More information

MITRAS MATERIALS GMBH

MITRAS MATERIALS GMBH MITRAS MATERIALS GMBH Friedrich-Ochs-Str. 2 92637 Weiden/Opf. Tel.: 0961 / 89-810 / 89-812 Fax: 0961 / 89-672 Directory of services L a b o r a t o r y MITRAS MATERIALS GMBH Edition 02/18 Rev. 08 page

More information

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006 For the Attention of: Mr Ian Davies Mideas Limited 12 Openshaw Drive Blackburn Lancashire BB1 8RH With Compliments DATE REPORT ISSUED: 10/11/2006 PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : 99316

More information

Classification report No K1

Classification report No K1 Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Classification report No.

More information

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components s own test laboratory issues test certificates for every material under the FAR / EASA guidelines on behavior in fire. ANALYSING. TESTING. CERTIFYING. KNOWLEDGE. EXPERIENCE. CAPABILITY. Aviation Components

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

EU Mutual Recognition Technical Requirements

EU Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 1.a General description of the product... 1 1.b Application limitations... 1 1.c Intended use... 2 1.d System context... 2 2. DESIGN EVALUATION... 2 2.a Engineering evaluation

More information

Test report no

Test report no Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2017-2132-1

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance

More information

National Standard of People s Republic of China

National Standard of People s Republic of China Translated English of Chinese Standard: GB 8410-2006 www.chinesestandard.net Email: Sales@ChineseStandard.net ICS 13. 220. 40 T 09 National Standard of People s Republic of China GB GB 8410-2006 Replacing

More information

Urban Wildfire Interface: Exterior Wall Wildfire Testing

Urban Wildfire Interface: Exterior Wall Wildfire Testing Urban Wildfire Interface: Exterior Wall Wildfire Testing PN# 04018 Conducted for: WILDLAND FIRE TASK GROUP TESTING CONDUCTED ON APRIL 5 AND MAY 6, 2004 REPORT ISSUED ON: APRIL 25, 2004 Kelso, Washington

More information

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10 Test Report : SZTY1211030991TS Date: DEC 04, 2012 Page 1 of 10 HAPPY ARTS&CRAFTS(NINGBO)CO.,LTD/ HAPE INTERNATIONAL(NINGBO)LTD 9-27 NANHAI ROAD, DAGANG INDUSTRIAL CITY, BEILUN, NINGBO, CHINA PC:315800

More information

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5 Test Report No.: AJHL1605004946FT Date: JUN.02, 2016 Page 1 of 5 The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description OFFICE CHAIR Type/Style K-106AH

More information

Determination Of Fire Effluents From Products On Railway Vehicles

Determination Of Fire Effluents From Products On Railway Vehicles Determination Of Fire Effluents From Products On Railway Vehicles Beth Dean Technical Development Officer Bodycote Warringtonfire beth.dean@bodycote.com Rail Interiors Expo Open Forum Amsterdam on 6 th

More information

VIBRATION TEST REPORT

VIBRATION TEST REPORT Report No. :HS1505160024A-1 Version:B VIBRATION TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model

More information

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24 Report No. :HS1505160024A-2 Version:B SHOCK TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model Name

More information

Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4

Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4 Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4 THE BENCHMARK IN FIRE TESTING ENV 1187 Tests for European Roofing Products This ENV 1187 describes four methods for determining the

More information

Report Test Report

Report Test Report ÖTI Institut für Ökologie, Technik und Innovation GmbH Report 70535 Test Report Applicant FIDIVI Tessitura Vegnano S.p.A. Regione Masio 19 / bis 10046 Poirino (TO) ITALIEN Reference Mr. Alessandro Avenati

More information

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide D.G Mulligan Pr Eng* * Managing Director, Phambili Interface (Pty) Ltd, P O Box 193, Edenvale, 1610, South Africa; e-mail: dmulligan@weidmuller.co.za

More information

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH Contego Latex Fire Barrier Intumescent (Also marketed in Canada by Pyrologistics,

More information

Prototype Test Report Quadri*Sil 300 Line Post Insulators Report Number: R

Prototype Test Report Quadri*Sil 300 Line Post Insulators Report Number: R ANSI C29.17 Prototype Test Report Quadri*Sil 300 Line Post Report Number: R12-11-03 Table of Contents Section Prototype Tests ANSI Clause Page I. Tests on Interfaces and Connections of End Fittings 7.1

More information

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen :.... Test Report No.: 11504 I 40047 Date: 0603.2015 BASF SE Brandschutztechnik G-PMF/A - A521 0-67056 Ludwigshafen Test accortling to ISO 4589 Part 2 : 2006-06 Plastics - Determination of burning behaviour

More information

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter Oxygen Bomb Calorimeter EN ISO 1182: Reaction to fire tests for building products Determination of the heat of combustion. This instrument determines the potential maximum total heat release of a product

More information

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference: Exova Warringtonapt Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com BS EN 14351-1:2006 Test

More information

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air) Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear ETS12-01-02 Specification ETS12-01-02 Ver 3 Contents 1. Purpose

More information

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft.   T F ederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / etherlands Organisation for Applied Scientific Research TO report E 13823:22 "Single Burning Item" and E 11925-2:22 "Ignitability"

More information

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours MIE TALK - July 2016 Compiled by Pieter H. Coetzee Introduction Far too many fires and burn injuries result from the careless or inappropriate use of petrol. Because petrol is so common in our environment,

More information

Test Report No

Test Report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Ebh@exova.com W: www.exova.com Test Report No. 2015-1365

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12 Test Report No.: SHHG1211042519BC Date: JAN.31,2013 Page: 1 of 12 GOLDEN MOTOR TECHNOLOGY CO., LTD BLOCK 8, MODERN INDUSTRIAL CENTER, 801 CHANGWU MIDDLE ROAD, CHANGZHOU, JIANGSU, CHINA 213164 The following

More information

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB Ms. Andrea Bernstein PDP Product Development Engineer BASF Corporation 1609 Biddle Avenue Wyandotte, MI, 48192 Re: Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No.

More information

EUMOS SYMPOSIUM 2017

EUMOS SYMPOSIUM 2017 EUMOS SYMPOSIUM 2017 CONTACT Martin Keller TÜV NORD Mobilität GmbH & Co. KG IFM Whole Vehicles Safety of Loads Group Phone: 0049 (0) 511/ 9986-1274 Fax: 0049 (0) 511/ 9986-1998 ladungssicherung@tuev-nord.de

More information

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure Hong-Zeng (Bert) Yu International Water Mist Conference October 28 29, 2015 Amsterdam, The Netherlands Background To reduce the

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

Cast Resin Transformers

Cast Resin Transformers Cast Resin Transformers Since their appearance and introduction in the electric market, Cast Resin Transformers (CRT) have won an important position in every sector due to: The use of special epoxy self-extinguishing

More information

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

ASTM E 1354 Caloric Content Determination of 3M Polyurethane Adhesive Sealant 540 ELECTRONIC COPY ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540" A Report To: 3M Center Industrial and Transportation Division 3M Center, Building 223-1N-14 St, Paul,

More information

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil) Ergon Energy Corporation Limited Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear ETS12-01-03 Specification ETS12-01-03 Ver 3 Contents 1. Purpose and Scope...

More information

INTERNATIONAL STANDARD. Download aus SNV-Livelink, Schweiz. Normen-Vereinigung SNV. Max Peter

INTERNATIONAL STANDARD. Download aus SNV-Livelink, Schweiz. Normen-Vereinigung SNV. Max Peter INTERNATIONAL STANDARD ISO 9994 Fourth edition 2005-09-01 Lighters Safety specification Briquets Spécifications de sécurité Reference number ISO 9994:2005(E) ISO 2005 PDF disclaimer This PDF file may contain

More information

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia NFPA 285 TEST REPORT Report No.: H1152.01-121-24 Test Date: June 1, 2017 Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia WALL SYSTEM: Exterior Non-loadbearing Wall Assembly COMBUSTIBLE COMPONENTS:

More information

Report Number BTC 12261F

Report Number BTC 12261F Report Number BTC 6F A FIRE RESISTANCE TEST ON A 5m HIGH X m WIDE GYPROC SHAFTWALL SYSTEM INCORPORATING A 6mm METAL STUD FRAMEWORK CLAD WITH A DOUBLE LAYER OF 5mm GYPROC FIRELINE, EXPOSED TO THE FIRE FROM

More information

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength Report No: 181947 Test of: Reversible aluminium/timber window Tested to: BS 6375-2:2009 Performance of windows & doors Part 2: Operation & strength For: A/S Peder Nielsen Beslagfabrik Norregade 25 Bronderslev

More information

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Fire resistance test in accordance

More information

Report Number BTC 12024F

Report Number BTC 12024F Report Number BTC F A FIRE RESISTANCE TEST ON A GYPROC GYPWALL PARTITION INCORPORATING A DOUBLE LAYER OF mm SOUNDBLOC EACH SIDE OF S STUDS, CONDUCTED IN ACCORDANCE WITH BS EN 4:999. Test Date: 9 th June

More information

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance

More information

EN 1154:1997 / A1:2002

EN 1154:1997 / A1:2002 Exova Warringtonapt Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com EN 1154:1997 / A1:2002

More information

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent. Technical Guide Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent. The trusted name in copper. Contents Copper

More information

No , Vers.1

No , Vers.1 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems. Spraytecs technologies ltd SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems. Technical Data General Description The SPRAYTECS Series

More information

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...

More information

Flash Point Process Analyzer

Flash Point Process Analyzer Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,

More information

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address: Test Verification Of Conformity On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the

More information

Durable Goods Labelling Compliance

Durable Goods Labelling Compliance productoverview Durable Goods Labelling Compliance Durable goods require labels that give crucial instructions, product details and safety information. The labels have to stay in place and remain legible

More information

Date of hosting on website: 30 th August 2018 Last date for comment: 14 th September 2018

Date of hosting on website: 30 th August 2018 Last date for comment: 14 th September 2018 Date of hosting on website: 30 th August 2018 Last date for comment: 14 th September 2018 CHECK LIST FOR PREPARING AMENDMENT TO AUTOMOTIVE INDUSTRY STANDARD (AIS) Amd. 02 to AIS-123 Part 1 SR. PARTICULARS

More information

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 oééçêí=çå=cáåçáåöë= = OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 Commissioning Party: Renusol Europe GmbH Mr Nils Rossbach Piccoloministr. 2 51063 Cologne Testing location:

More information

WESTONE ONYX BLACK WEI-408B2

WESTONE ONYX BLACK WEI-408B2 WESTONE ONYX BLACK WEI-408B2 DETECTING AND ANALYZING REPORT Series Number 2012 - (FX) -020 Samples Name Westone Onyx Black Roofing Slate WEI-408B2 Entrusting Organization Shaanxi Westone Industry and Trade

More information

OSU Rate of Heat Release Apparatus

OSU Rate of Heat Release Apparatus OSU Rate of Heat Release Apparatus THE BENCHMARK IN FIRE TESTING OSU Rate of Heat Release Apparatus FAR 25.853 (a-1), FAA Fire Test Handbook Chapter 5, ASTM E 906 Configuration A Standard Test Method for

More information

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves CLASSIFICATION NOTES Type Testing Procedure for Crankcase Explosion Relief Valves Contents 1. Scope, Application 2. Recognized Standards 3. Purpose 4. Test Facilities 5. Explosion Test Process 6. Testing

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

TESTING OF FUELS : FLASH AND FIRE POINT

TESTING OF FUELS : FLASH AND FIRE POINT Department of Mechanical Engineering Indian Institute of Technology New Delhi II Semester -- 2017 2018 MCL 241 Energy systems and Technologies TESTING OF FUELS : FLASH AND FIRE POINT 1. Introduction The

More information

Recent enhancement to SI-ICE combustion models: Application to stratified combustion under large EGR rate and lean burn

Recent enhancement to SI-ICE combustion models: Application to stratified combustion under large EGR rate and lean burn Recent enhancement to SI-ICE combustion models: Application to stratified combustion under large EGR rate and lean burn G. Desoutter, A. Desportes, J. Hira, D. Abouri, K.Oberhumer, M. Zellat* TOPICS Introduction

More information

SFI SPECIFICATION 3.3 EFFECTIVE: AUGUST 26, 2016 *

SFI SPECIFICATION 3.3 EFFECTIVE: AUGUST 26, 2016 * SFI SPECIFICATION 3.3 EFFECTIVE: AUGUST 26, 2016 * PRODUCT: Driver Accessories 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

FIBRE UKANOL ES REACTIVE FLAME RETARDANT ADDITIVE FOR POLYESTER

FIBRE UKANOL ES REACTIVE FLAME RETARDANT ADDITIVE FOR POLYESTER FIBRE REACTIVE FLAME RETARDANT ADDITIVE FOR POLYESTER ADDITIVE FOR PERMANENT FLAME RETARDANCY IN POLYESTER FIBRES The trend towards the use of synthetic polymers in the textile industry is increasing continuously.

More information

EN Door closers LEVASSEUR. 5-2

EN Door closers LEVASSEUR. 5-2 Door closers 5-2 LEVASSEUR. What is the CE marking? The letters CE applied to the product allow the manufacturer to prove his conformity with all applicable European directives. The CE marking is issued

More information

Technical Specification

Technical Specification 1 Power and Energy Group Deputy Vice President, Generation November 25, 2014 Our Ref:022-006892-2014 The Israel Electric Corporation Ltd. Generation Division Revision no: 1 Issued date Page 1 of Specification

More information

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date: Title: Fire Resistance Test In Accordance With BS EN 1364-1: 1999 On A Glazed Screen Assembly WF Report No: 164311, Prepared for: AGC Flat Glass Europe. Chaussee de la Hulpe 166 1170 Brussels. Date: 19

More information

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building

More information

NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents

NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents Reference: Various TIA 13-1 (SC 13-8-21/TIA Log #1098) Tentative Interim Amendment NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents 2013 Edition Pursuant to Section 5 of the NFPA

More information

«DO160/ED14» - Jessica France

«DO160/ED14» - Jessica France Training Workshop «DO160/ED14» - Jessica France Pros and cons of hermetically sealed boxes for environmental qualification of electrical items Edouard ZUNDEL Systems Qualification Engineer for Mechanical

More information

Services Directory updated: January 2016

Services Directory updated: January 2016 Kulmbacher Straße 76 95213 Münchberg Tel. 09281/409-8720 Fax 09281/409-8799 E-mail: pruefamt@hof-university.de Director: Prof. Oliver Lottes Services Directory updated: January 2016 A) Mechanical and Technological

More information

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5 28 October 2016 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions

More information