Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )
|
|
- Linette Warren
- 6 years ago
- Views:
Transcription
1 Test certificate Nr. 3666/4421-a -Fe/Wi- page 1 TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY MPA BRAUNSCHWEIG Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( ) Applicant: Wacker-Chemie GmbH Friedrich-von-Heyden Platz Nünchritz Date of submission of application: Reference: S-S-F-1 Date of receipt: Content of application: Tests for development of construction material class B 1 (not readily igniting material) according to standard DIN : para Name: Siliconhermetic "Elastosil 7600". Notice: If the abovementioned construction material is not used for the purposes described in regulation MBO 2 para. 9 p.1, the general construction inspection test certificate is not required. This test certificate is not valid if the tested construction material is used as building product for the purposes set forth in the Federal State Civil Engineering Regulation (MBO 20 para. 3). This test certificate does not substitute the certificate required by Federal State construction/construction inspection regulations in certain cases. In the procedure of construction inspection, this test certificate can be seen as a supporting document: - for the certificate of approval in the case of standardized building products - for an applicability certificate for non-standardized building products. The certificate for aging-resistance according to standard DIN para. 6.2 is not submitted. Follow the guidance of standard DIN : annex D, specially the provisions for external inspection. The test certificate comprises 5 pages and 3 annexes. For publishing (also partially) the contents of the test certificate and referral to the tests for commercial purposes, the written permission of the testing body is required in every individual case. The first and the last page of this test certificate have to be affixed with a seal. The test material is used. Testing laboratory for civil Ph. +49-(0) Norddeutsche Landesbank Hannover engineering materials Technical University of Braunschweig Fax. +49-(0) account (BLZ ) Beethovenstraße 52 mpa@tu-bs.de Swift-code: NOLADE 2H D Braunschweig VAT -ID-Nr. MPA-DE
2 Test certificate Nr. 3666/4421-a -Fe/Wi- page 2 Accredited laboratories according to standard DIN EN Accreditations are valid for the test method DAP-P-C DKD-K mentioned in this certificate. Test material: Date of reception of the test material: Sampling: by applicant Product name given by applicant: "Elastosil 7600". Description: RTV-1-siliconhermetic, name "Elastosil 7600", in a tube made of metal or monolith mineral construction materials. Tube measures: length 100 cm width 4 cm depth 2 cm Table 1: thickness, mass per surface unit, apparent density minimal measured value arithmetic mean maximal measured value thickness (6 measured values pro sample) [mm] u 20 mass per surface unit [kg/m 2 ] apparent density [kg/m 3 ] u 1501 Special notices: material was tested in a filled tube with two Eterplan-N strips or in a completely filled tube between two U-sheets (L 100 cm W 7, 5 cm H 2 cm). Table 2: Test results according to standard DIN : para. 6.2, civil engineering materials class B 2 (average flammability). temporal data since the beginning of the test: sample nr: ignition: [s] benchmark achievement [s] highest flame [cm] decomposition of burning material Evaluation: [s] All samples were in accordance with the requirements set forth in standard DIN : para No droplets during combustion process.
3 Test certificate Nr. 3666/4421-a -Fe/Wi- page 3 Test results of the Brandschacht (combustion chamber) method Test date: Samples A and B: Material was tested in an entirely filled tube between two U sheets. Sample C: Material was tested in an entirely filled tube between two Eterplan-N-plates. Tube measures: length 100 cm width 4 cm depth 2 cm. Line nr. results of the Brandschacht- method (1 st part) measured values /sample A B C D 1 number of test task according to DIN : table highest flame at the lower edge of samples [cm] time *) [min] fusion/combustion time *) [min:s] observation on the back side of sample 5 flaming/glowing Time *) [min:s] 6 changes in colour Time *) [min:s] 7 8 droplets during burning begin *) [min:s] duration: test material droplets as single drops 9 test material droplets continuously particles of sample falling during combustion process begin *) duration: singly falling particles of the sample 12 continuously falling particles of the sample 13 duration of aftercombustion on the filter bottom (max) effect of droplets/falling material to the flame of burner [min:s] 07:51 [min:s] yes 00:05 14 time from *) [min:s] *) time from the beginning of the test
4 Test certificate Nr. 3666/4421-a -Fe/Wi- page 4 Line nr. results of the Brandschacht (combustion chamber) method (2 nd part) 15 early ending of the test the end of combustion process of sample *) 16 test possible interruption time *) 17 measured values /sample A B C D [min:s] [min:s] aftercombustion after the test end duration [min:s] 03:37 03:32 01:12 18 number of samples front side of sample yes yes yes 20 back side of sample 21 highest flame [cm] afterglow after test end duration [min:s] place of origin: number of samples 24 lower part of sample 25 upper part of sample 26 front side of sample 27 back side of sample 28 smoke density < 400 [%*min] 66,2 116,1 32,3 29 > 400 (very intensive production of smoke) [%*min] 30 graph in annex nr residue lengths **) individual values: [cm] average values of individual tests photo from samples in annex nr. [cm] 51 1 average values of all tests [cm] 50 temperature of the burnable gas maximum of the average values [ C] 121,3 132,7 106,8 35 time*) [min:s] 09:57 10:00 09:37 36 graph in annex nr notice: **) For firestop equipment show data of backing board and foam layer separately
5 Test certificate Nr. 3666/4421-a -Fe/Wi- page 5 3. Evaluation: - All samples met the average flammability requirements (class B2) set forth in DIN : para With none of the samples falling (droplets) of material or ignition of the filter paper occurred. - All samples tested in the combustion chamber met the requirements set forth in DIN : para The tested material can therefore be classified as not readily igniting material according to the standard DIN : (civil engineering materials class B1). 4. Special notice: 4.1 This fire test result is valid only for the civil engineering material described in para. 1. The use of this material in combination with other building materials (e.g. overlays, fire stop equipment) can influence the burning characteristics of this material in a way that the above mentioned classification becomes invalid. The burning characteristics of this building material in conjunction with other materials need to be tested separately according to the standard DIN According to the standard DIN : materials need to be marked with the following notice: DIN 4102-B1 4.3 The validity of the test certificate 3666/4421-a expires on A renewal can only be made taking into account future requirements of the construction inspection. Director deputy Responsible official /signature/ /signature/ (RD. Doctor of technical sciences Wesche) (Doctor of technical sciences Dobbernack) /signature/ (Laboratory technician H. Wiegard) Braunschweig, 2 nd of July 2001.
6 Test certificate Nr. 3666/4421-a -Fe/Wi- page 6
7 Test certificate Nr. 3666/4421-a -Fe/Wi- page 7
8 Test certificate Nr. 3666/4421-a -Fe/Wi- page 8 Sample of test material after end of test. Photo 1 Photo 1: shows sample A after test.
TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS
TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY MPA BRAUNSCHWEIG Inspection report nr (3329/2706)
More informationTEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5
Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH
More informationTest report No
Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2211 for applying
More informationTest report No
Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2296 for applying
More informationTEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5
Page: 1 of 5 IGEPA GROUP GMBH & CO.KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S FRONTLIT 510
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2016-1390
More informationTest Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6
Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1940
More informationTest Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5
Test Report AJHL1603002392FB Date: APR.06, 2016 Page 1 of 5 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2015-1661
More informationGermany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7
Germany B1 Fire Rating kraft paper products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604 685 0342 info@molodesign.com www.molodesign.com molo kraft paper
More informationEuropean B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd
European B1 Fire Rating soft collection softwall + softblock Fire Retardant (FR) Treated textile products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604
More informationTest Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6
Test Report No. AJHL1606005818FB Date: JUN.21, 2016 Page 1 of 6 HAINING JINMAO WARP KNITTING CO., LTD NO. 38 LUHONG ROAD DINGQIAO TOWN HAINING CITY ZHEJIANG CHINA The following sample(s) was / were submitted
More informationTest Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6
Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 1 of 6 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s)
More informationTest Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6
Test Report. AJHL1610011324FB-2 Date: OCT.24, 2016 Page 1 of 6 POSTER AND PANEL CPERE ANDORRA, SN, POL. IND, ILLA,SUD, NAUS, 4, 5, I6,08650, SALLENT, BARCELONA, SPAIN The following sample(s) was were submitted
More informationTEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5
Reference. : TRHZ0630_R Date : v. 27, 202 Page.: of pplicant : ddress : HINING LOFTY XUN BNNER TEXTILE CO., LTD. NO.70-,LONGXING ROD, HICHNG STREET, HINING CITY, ZHEJING, CHIN. The following merchandise
More informationTest report no
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2015-1339
More informationFIRE TEST REPORT FH 5154
1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5154 CONE CALORIMETER TEST AND NCC SPECIFICATION C1.10
More informationReport Test Report
ÖTI Institut für Ökologie, Technik und Innovation GmbH Report 70535 Test Report Applicant FIDIVI Tessitura Vegnano S.p.A. Regione Masio 19 / bis 10046 Poirino (TO) ITALIEN Reference Mr. Alessandro Avenati
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1031
More informationClassification report No K1
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Classification report No.
More informationFIRE TEST REPORT FH 5078
1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5078 CONE CALORIMETER TEST AND NZBC ACCEPTABLE SOLUTIONS
More informationTest report no
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2017-2132-1
More informationSound-absorbing spacer Sorp10
Sponsor: Reference number: 7.3 / 27080 This document is only a translated version; not legally attested Max Frank GmbH & Co. KG Mitterweg 1 94339 Leiblfing Federal Institute for Materials Research and
More informationFIRE TEST REPORT FH 5728
1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5728 CONE CALORIMETER TEST AND NZBC VERIFICATION METHOD
More informationCONTINUOUS IMMERSION AND DUST TEST REPORT
Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei
More informationInfluence of mounting tube diameter on anemometer output
Influence of mounting tube diameter on anemometer output In cooperation with: Adolf Thies GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Deutsche WindGuard Wind Tunnel Services GmbH Oldenburger Str.
More informationTest Report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Ebh@exova.com W: www.exova.com Test Report No. 2015-1365
More informationDetermination Of Fire Effluents From Products On Railway Vehicles
Determination Of Fire Effluents From Products On Railway Vehicles Beth Dean Technical Development Officer Bodycote Warringtonfire beth.dean@bodycote.com Rail Interiors Expo Open Forum Amsterdam on 6 th
More informationVAUTH ANALYSING. TESTING. CERTIFYING. aviation components
s own test laboratory issues test certificates for every material under the FAR / EASA guidelines on behavior in fire. ANALYSING. TESTING. CERTIFYING. KNOWLEDGE. EXPERIENCE. CAPABILITY. Aviation Components
More informationAugust 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597
August 7, 2015 Mr. Stephen Kokenes Phone: 919-380-6636 Nomaco Inc. Fax: 919-269-7936 501 NMC Drive Email: skokenes@nomaco.com Zebulon, NC 27597 Subject: Report of ASTM D545 Testing Project Name: Samples
More informationTest report P E. J. Magner Dipl.-Ing. (FH) N. Machill
Kiwa Polymer Institut GmbH Quellenstraße 3 D-65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 8464-2-E Testing order: Tests on the coating Wecryl 124
More informationTitle: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:
Title: Fire Resistance Test In Accordance With BS EN 1364-1: 1999 On A Glazed Screen Assembly WF Report No: 164311, Prepared for: AGC Flat Glass Europe. Chaussee de la Hulpe 166 1170 Brussels. Date: 19
More informationVIBRATION AND MECHANICAL SHOCK TEST REPORT
Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name
More informationTest Report. on Type Testing of Diaphragm Gland Seal Valves Type RWH-03 according to EN ISO 10297:2014
HBAM Test Report Bundesanstalt für Materialforschung und -prüfung on Type Testing of Diaphragm Gland Seal Valves Type RWH-03 according to EN ISO 10297:2014 Reference 2-1478/2015 DGA reference DGA-14-068
More informationRECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS
Phone : +32 2 742 96 82 Fax : +32 2 732 12 18 e-mail : recyclass@plasticsrecyclers.eu website: www.recyclass.eu RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS Standard Laboratory Practice Version 1.0 Published
More informationTHERMAL SHOCK TEST REPORT
Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number
More informationEvidence of performance Reduction of impact sound pressure level by floor coverings
Evidence of performance Reduction of impact sound pressure level by floor coverings Test report No. 14-003029-PR01 (PB X3.1-F03-04-en-01) Client Product Getzner Werkstoffe GmbH Herrenau 5 6706 Bürs Austria
More informationTHE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23
P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23 Canceling P.S.C. Mo. No. 5 Sec. 4 Original Sheet No. 23 PURPOSE: The purpose of this Rider SR is to implement the solar rebate established through 393.1030
More informationPermit Holder. Permitted Equipment
Air Quality Registration Stationary Compression Ignition Internal Combustion Engine (Less than 400 Brake Horsepower) Permit No. Project No. Description Date Testing No Plant Number: Under the Direction
More informationEC-CERTIFICATE OF CONFORMITY 0432 CPD 0031
MATERIALPRÜFUNGSAMT NORDRHEI N - WESTFALEN EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031 In compliance with the Directive 89/106/EEC of the Council of European Communities of 21 December 1988 on the approximation
More informationEUMOS SYMPOSIUM 2017
EUMOS SYMPOSIUM 2017 CONTACT Martin Keller TÜV NORD Mobilität GmbH & Co. KG IFM Whole Vehicles Safety of Loads Group Phone: 0049 (0) 511/ 9986-1274 Fax: 0049 (0) 511/ 9986-1998 ladungssicherung@tuev-nord.de
More informationCertification Scheme
Certification Scheme Single use barbecues burning solid fuels according to DIN EN 1860-4 (Edition: November 2013) DIN CERTCO Alboinstraße 56 12103 Berlin Tel: +49 30 7562-1131 Fax: +49 30 7562-1141 E-Mail:
More informationThis is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"
This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)" Note to Permit Writer: This condition is for existing engines (commenced
More informationSynthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids
Description Compressed air has become a major form of energy and the reliable generation of compressed air is vital. Operators require compressors to function perfectly over and beyond entire service intervals.
More informationCERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012
:~ ~~~~~============~----------------------~ Umwelt Bundes Amt @ For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000035014 Certified
More informationEU Mutual Recognition Technical Requirements
1. PRODUCT DESCRIPTION... 1 1.a General description of the product... 1 1.b Application limitations... 1 1.c Intended use... 2 1.d System context... 2 2. DESIGN EVALUATION... 2 2.a Engineering evaluation
More informationFIRE REGULATION IN FURNITURE WORLD OVERVIEW
6/8 FIRE REGULATION IN FURNITURE WORLD OVERVIEW For your internal use only http://www.crepim.com / 1 Since many years, comprehensive studies of the ignition hazard of upholstery and covering materials
More informationTest Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 1 of 3 HONGGE (GUANGZHOU) PAPER CO., LTD BUILDING 1, HE TAI INDUSTRY ZONE, HE TAI ROAD NO.2, HE BIAN, JIA HE TOWN, BAI YUN DISTRICT, GUANGZHOU.
More informationTHE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-3R Extension number: 00
Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) COMMUNICATION Concerning (1) : - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued
More informationRockfon BV lndustrieweg JG Roermond NIEDERLANDE ISclKf. Ceiling Element
Postfach 801 140. D-70511 Stuttgart Universitit Stuttgart DAP - PL - 2907.07 Test Report Client: Rockfon BV lndustrieweg 15 6045 JG Roermond NIEDERLANDE Order-No. (Client): Order No. (MPA): Test Item:
More informationSTS Directory Accreditation number: STS 0630
International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 TÜV SÜD Schweiz AG Geschäftsbereich Process Safety WRO 1055.5.24 Mattenstrasse 24 CH-4002 Basel Head: Mischa Schwaninger
More informationProduct Evaluation Report
Product Evaluation Report PER-11044 Page 1 of 5 Initial Listing July, 2011 This Document Published By: Re-Approved May, 2018 Listed Product Flat & Raised Panel Cabinet Doors 5.2mm Industrial Panel with
More informationCLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves
CLASSIFICATION NOTES Type Testing Procedure for Crankcase Explosion Relief Valves Contents 1. Scope, Application 2. Recognized Standards 3. Purpose 4. Test Facilities 5. Explosion Test Process 6. Testing
More informationDispensette. Testing Instructions (SOP) 1. Introduction. May 2009
Dispensette Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of the bottle-top dispenser. The following Testing Instructions describe
More informationManufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:
CERTIFICATION APPLICATION Reciprocating internal combustion engines Certificate No.: EX Exhaust emission measurement - Part 1: Test-bed measurement of gaseous and particulate exhaust emissions Ref.: ISO
More informationDÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen
Evaluation of the image quality of a radiographic film emulsion AGFA D7 exposed by X-rays and developed by machine processing (8 min cycle time at 29 C) using Dürr NDT XR D-6 NDT developer and XR F-6 NDT
More informationCertification Scheme
Certification Scheme Water-based surface-embedded heating and cooling systems in accordance with DIN EN 1264 (Version: November 2009) DIN CERTCO Alboinstraße 56 12103 Berlin Tel: +49 30 7562-1131 Fax:
More informationFire protection accessories for the glazing industry
Fire protection accessories for the glazing industry Fire protection for europe Made in germany Content General Definition The Rolf Kuhn GmbH Fire classification rating 4 7 4 4 5 5 6 7 Product overview
More informationGuideline of the Railway Vehicles Coordination Committee (Draft Guideline DVS 1619)
Guideline of the Railway Vehicles Coordination Committee (Draft Guideline DVS 1619) Procedure for the certification of welding manufacturers for welding railway vehicles and components according to DIN
More informationPRODUCT INFORMATION RENOLIN DTA. Lubricating and hydraulic oils. Description. Advantages. Application. Specifications
Description Hydraulic and lubricating oils made from selected base oils with additives to improve ageing stability and corrosion protection. The products in the RENOLIN DTA series are hydraulic and lubricating
More informationExample Notification of Compliance Status Report a
Example Notification of Compliance Status Report a National Emission Standards for Hazardous Air Pollutants: Stationary Reciprocating Internal Combustion Engines 40 CFR part 63, subpart ZZZZ Note: The
More informationTechnical Report. No. KO250.3E. on the TRAILER CONTROL MODULE
Technical Report No. KO250.3E on the TRAILER CONTROL MODULE Mobilität TÜV NORD Mobilität GmbH & Co. KG IFM Institute for Vehicle Technology and Mobility Adlerstraße 7 45307 Essen Tel.: +49 (0)201 825-4120
More informationUrban Wildfire Interface: Exterior Wall Wildfire Testing
Urban Wildfire Interface: Exterior Wall Wildfire Testing PN# 04018 Conducted for: WILDLAND FIRE TASK GROUP TESTING CONDUCTED ON APRIL 5 AND MAY 6, 2004 REPORT ISSUED ON: APRIL 25, 2004 Kelso, Washington
More information23-Jul-14. VCA job number: CSQ Date: 23 July Dear Sirs,
VCA job number: CSQ300864 Date: 23 July 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC Directive
More informationEin Unternehmen der SCHAUENBURG International Gruppe Fire sleeve - F 88 SC Technical data Product details
Fire sleeve - F 88 SC The extruded fire sleeve with silicone coating, high resistance and material density. Available in the standard colour red, but also in other colour coding. Backing material Coating
More informationAnnex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-K-15102-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 05.07.2017 to 04.07.2022 Date of issue: 05.07.2017
More informationANNEX B TECHNICAL SPECIFICATIONS PORTABLE SOLAR-POWERED LIGHTS
ANNEX B TECHNICAL SPECIFICATIONS PORTABLE SOLAR-POWERED LIGHTS ITB/2017/869 1 GENERAL SPECIFICATION 1. There shall be 2 categories of lights for evaluation under this tender : A. With Mobile Device Charging
More information:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen
:.... Test Report No.: 11504 I 40047 Date: 0603.2015 BASF SE Brandschutztechnik G-PMF/A - A521 0-67056 Ludwigshafen Test accortling to ISO 4589 Part 2 : 2006-06 Plastics - Determination of burning behaviour
More informationNCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles
The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification
More informationIBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg
IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg REPORT IB-07-8-003 about the experimental testing of enclosed-break devices Thermostat type 077Bxxxx/L
More informationTranslation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten
Allgemeine bauaufsichtliche Zulassung () Zulassungsstelle Bauprodukte und Bauarten Bautechnisches Prüfamt Eine vom Bund und den Ländern gemeinsam getragene Anstalt des öffentlichen Rechts Member of EOTA
More informationStandard Classification System for Carbon Blacks Used in Rubber Products 1
Designation: D 1765 04 Standard Classification System for Carbon Blacks Used in Rubber Products 1 This standard is issued under the fixed designation D 1765; the number immediately following the designation
More informationPermit Holder. Permitted Equipment
Air Quality Registration Stationary Spark Ignition Internal Combustion Engine (Less than 400 Brake Horsepower) Permit No. Project No. Description Date Testing No Plant Number: Under the Direction of the
More informationTest report no
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2014-1452-2
More informationPart 70 Operating Permit Amendment
Part 70 Operating Permit Amendment Effective Date: February 18, 2016 Facility Name: Scherer Steam-Electric Generating Plant Facility Address 10986 Highway 87 Juliette, Georgia 31046, Monroe County Mailing
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17435-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 30.09.2016 to 08.12.2018 Holder of certificate: k3works
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17435-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.12.2017 to 08.12.2018 Holder of certificate: k3works
More informationTITLE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
250-RICR-120-05-8 TITLE 250 - DEPARTMENT OF ENVIRONMENTAL MANAGEMENT CHAPTER 120 - AIR RESOURCES SUBCHAPTER 05 - AIR POLLUTION CONTROL PART 8 - Sulfur Content of Fuels 8.1 Purpose The purpose of this regulation
More informationCOUNTRY: Bulgaria. On-going and planned performance indicators / benchmarking systems
COUNTRY: Bulgaria On-going and planned performance indicators / benchmarking systems Presentation prepared by SEWRC` officials 26.09.2013, Bucharest/Romania Danube Water Program / Benchmarking Workshop
More informationAPIB Test Specification No. 00b General Part B SWISS HAIL IMPACT PROTECTION REGISTER (HSR) / 00b-18en Version 1.02
Association of Public Insurance Companies (APIB) Association des établissements cantonaux d assurance incendie APIB Test Specification No. 00b General Part B 01.12.2018 / 00b-18en Version 1.02 APIB Test
More informationZürich Testing on Fuel Effects and Future Work Programme
Zürich Testing on Fuel Effects and 2016-2017 Future Work Programme Benjamin Brem 1,2, Lukas Durdina 1,2 and Jing Wang 1,2 1 Empa 2 ETH Zürich FORUM on Aviation and Emissions Workshop Amsterdam 15.04.2016
More informationSKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition
Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They
More informationRENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU
Description RENOSAFE FireProtect products are fire resistant hydraulic fluids based on special synthetic esters. The selected organic ester base oils have highest purity and show high oxidation and thermal
More informationAnnex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11238 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 09.02.2016 to 08.02.2021 Holder of certificate: ContiTech
More informationPAKISTAN STANDARD LEAD ACID STARTER BATTERIES - Part-1: General Requirements and Methods of Test. (All Rights Reserved) PS: 206-1/2012 (2 nd Rev.
PAKISTAN STANDARD LEAD ACID STARTER BATTERIES - Part-1: General Requirements and Methods of Test (All Rights Reserved) PAKISTAN STANDARDS AND QUALITY CONTROL AUTHORITY, STANDARDS DEVELOPMENT CENTRE, PSQCA
More informationVertex Floors Ltd. Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay. P.R. China. Berlin, den
ALAB GmbH Wilsnacker Straße 15 10559 Berlin Simon Xia Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay Nach DIN EN ISO/IEC 17025:2005 durch die DAP Deutsches Akkreditierungssystem
More informationProduct Information. Bayferrox 610. Description. Specification. Specification. Brown pigment
Product Information Bayferrox 610 Description Type Delivery form Chemical class Colour Index CAS-No. REACH Specification Brown pigment Powder Synthetic iron oxide (mixture) Pigment red 101 (77491) / Pigment
More informationProduct Data Sheet 8412 NHU-519
The engineer's choice 8412 NHU-519 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationNon-domestic Renewable Heat Incentive Emissions Certificate
Non-domestic Renewable Heat Incentive Emissions Certificate This certificate provides evidence that the tested boiler meets the air quality requirements of the non-domestic Renewable Heat Incentive (RHI).
More informationSEPA Statement Processed Fuel Oil
SEPA Statement Processed Fuel Oil 1.0 Purpose This statement supports the production and use of Processed Fuel Oil (PFO) from waste lubricating oil and oil based mud cuttings. SEPA will not regulate as
More informationRegulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities
391-3-6-.24 Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities 1) Purpose. The purpose of Paragraph 391-3-6-.24 is to provide minimum uniform statewide
More informationRider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION
SAMPLE ORDINANCE 3/5/2012 Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION Section 1: Applicable Service Territory Net metering and electrical system interconnection is available on a first-come,
More informationReport No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength
Report No: 181947 Test of: Reversible aluminium/timber window Tested to: BS 6375-2:2009 Performance of windows & doors Part 2: Operation & strength For: A/S Peder Nielsen Beslagfabrik Norregade 25 Bronderslev
More informationSarnafil TS E. Polymeric membrane for roof waterproofing. Product Description
Roofing Product Data Sheet Edition 06.2013 Version no. 01 Sarnafil TS 77-18 E Polymeric membrane for roof waterproofing Product Description Sarnafil TS 77-18 E8 E (thickness 1.8 mm) is a Polyester reinforced,
More informationState of California AIR RESOURCES BOARD. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code
(Page 1 of 2) State of California AIR RESOURCES BOARD EXECUTIVE ORDER D 176 11 Relating to Exemptions Under Section 27156 of the Vehicle Code DINAN ENGINEERING, INC. HIGH FLOW COLD AIR INTAKE SYSTEM Pursuant
More informationMattest (Ireland) Ltd
Unit 18 University Hall, Sarsfield Road, Wilton, Cork Registration number: 289T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration
More informationMack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For
Report Packet Version No. Conducted For V = I = N = Valid; The reference oil/non-reference oil was evaluated in accordance with the test procedure. Invalid; The reference oil/non-reference oil was not
More informationE/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2
28 September 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions
More informationBERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax
BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building
More information