Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Size: px
Start display at page:

Download "Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005"

Transcription

1 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Period of validity: to Holder of certificate: Institute for International Product Safety GmbH Hein-Moeller-Straße 7-11, Bonn Tests in the fields: Industrial low-voltage, Assemblies,, Electromagnetic compatibility (EMC) and Flexible scope of accreditation Category I (Page 2-3) Within the given testing field marked with *), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, the free choice of standard or equivalent testing methods. The listed testing methods are exemplary. The testing laboratory maintains a current list of all testing methods within the flexible scope of accreditation. Flexible scope of accreditation Category III (Page 4-44) Within the scope of accreditation marked with **), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, to use standard testing methods listed here with different issue dates. This document is a translation. The definitive version is the original German annex to the accreditation certificate. 1/44

2 * Flexible scope of accreditation Category I Climatic Tests Kind of Test Test parameter Range Representative test method Temperature Temperature C EN EN Climate Temperature C EN Relative humidity % r.h. EN EN EN Thermal shock (Air/Air) Temperature C EN Na Corrosive Tests Kind of Test Test parameter Range Representative test method Salt mist Concentration of solution Temperature of test 5 % NaCl RT 50 C EN ISO 9227 EN chamber Relative humidity of test chamber % r.h. ASTM B UL 50 E Condensation water atmosphere Sulfur dioxide Temperature of test chamber Relative humidity of test chamber Temperature of test chamber Relative humidity of test chamber Corrosive gas RT 50 C ISO % r.h C EN ISO % r.h. 25 ppm SO2 Resistance to abrasion Pressing force N EN Number of actuation 10¹ 10⁷ Period of validity: to Translation - 2/44

3 Mechanical dynamic Tests Kind of Test Test parameter Range Representative test method Impact Test Impact energy 0,14 50 J EN Ehb, Ehc EN 50102, IEC Free fall Drop and topple Fall height mm EN Test surface Wood, concrete, steel Vibration, sinusoidal Frequency 5 Hz 3000 Hz EN Acceleration sinusoidal up to 91 g EN Vibration Frequency 5 Hz 3000 Hz EN broad-band random Acceleration (RMS) up to 60 g EN Shock, bump Duration up to 21 ms EN Acceleration shock up to 180 g Pulse shape Half-sine 1 no Test "Free fall repeated Procedure 2" Period of validity: to Translation - 3/44

4 ** Flexible scope of accreditation Category III Industrial low-voltage IEC ( ) EN ( ) DIN EN VDE ( ) Measuring relays and protection - Part 1: Common requirements IEC ( ) EN ( ) DIN EN VDE ( ) Electrical relays Part 3: Single input energizing quantity measuring relays with dependent or independent time IEC (1988) EN ( ) DIN EN VDE ( ) Electrical relays Part 6: Measuring relays and protection Equipment IEC ( ) EN ( ) DIN EN VDE ( ) Measuring relays and protection Part 151: Functional requirements for over/under current protection Period of validity: to Translation - 4/44

5 IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) HD ( ) DIN VDE VDE ( ) Low-voltage fuses Part 1: General requirements Low-voltage fuses Part 2: Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) Examples of standardized systems of fuses A to J IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN VDE VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) Low-voltage fuses Part 3: Supplementary requirements for fuses for use by unskilled persons (Fuses mainly for household and similar applications) Examples of standardized systems of fuses A to F Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices DIN EN VDE ( ) Period of validity: to Translation - 5/44

6 IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage fuses Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) Low-voltage assemblies Part 1: Type-tested and partially typetested assemblies DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) Low-voltage assemblies Part 2: Particular requirements for busbar trunking systems (busways) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) Low-voltage assemblies Part 3: Particular requirements for low-voltage assemblies intended to be installed in places where unskilled persons have access for their use Distribution boards Period of validity: to Translation - 6/44

7 IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage assemblies Part 4: particular requirements for Assemblies for construction sites (ACS) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage assemblies Part 5: Particular requirements for assemblies intended to be installed Outdoors in public places Cable distribution cabinets (CDCs) for Power distribution networks IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN 60529/A1 ( ) EN 60529/A2 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Degrees of protection provided by enclosures (IP code) Insulation coordination for within low-voltage systems Part 1: Principles, requirements and Period of validity: to Translation - 7/44

8 IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 1: General rules Low-voltage Part 2: Circuit-breakers Low-voltage Part 3: Switches, disconnectors, switch-disconnectors and fusecombination units Low-voltage Part 4-1: Contactors and motorstarters Electromechanical contactors and motor-starters : Up to 100 MHz amplifier power suitable for test level 3 (10V). : Up to 100 MHz amplifier power suitable for test level 3 (10V). Period of validity: to Translation - 8/44

9 IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /AC ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 4-2: Contactors and motorstarters AC semiconductor motor controllers and starters Low-voltage Part 4-3: Contactors and motorstarters AC semiconductor controllers and contactors for non-motor loads Low-voltage Part 5-1: Control circuit devices and switching elements Electromechanical control circuit devices Low-voltage Part 5-2: Control circuit devices and switching elements Proximity switches : Up to 100 MHz amplifier power suitable for test level 3 (10V). : Up to 100 MHz amplifier power suitable for test level 3 (10V). Period of validity: to Translation - 9/44

10 IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 5-3: Control circuit devices and switching elements Requirements for proximity devices with defined behaviour under fault conditions (PDF) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) Low-voltage Part 5-4: Control circuit devices and switching elements Methods of assessing the performance of low-energy contacts Special Low-voltage Part 5-5: Control circuit devices and switching elements Electrical emergency stop device with mechanical latching function Low-voltage Part 6-2: Multiple function Transfer switching element DIN EN VDE ( ) Period of validity: to Translation - 10/44

11 IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 6-2: Multiple functions Control and protective switching devices (or ) (CPS) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 7-1: Ancillary Terminal blocks for copper conductors IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A2 ( ) Low-voltage Part 7-2: Ancillary Protective conductor terminal blocks for copper conductors DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage Part 8: Control units for built-in thermal protection (PTC) for rotating machines Period of validity: to Translation - 11/44

12 IEC ( ) EN ( ) DIN EN VDE ( ) Programmable controllers Part 1: General information IEC 17D/416/CDV ( ) FprEN ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Programmable controllers Part 2: Equipment requirements and Tests Low-voltage assemblies Part 1: General rules : Up to 100 MHz amplifier power suitable for test level 3 (10V). No test with damped oscillation. No measurement of disturbance field strength. IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage assemblies Part 2: Power assemblies Period of validity: to Translation - 12/44

13 IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) IEC ( ) EN ( ) DIN EN VDE ( ) Low-voltage assemblies - Part 5: Assemblies for power distribution in public networks IEC 17D/416/CDV ( ) FprEN ( ) DIN EN VDE ( ) Low-voltage assemblies - Part 6: Busbar trunking systems (busways) IEC/TS ( ) DIN IEC/TS VDE V ( ) Low-voltage assemblies - Part 7: Assemblies for specific installations at public sites such as marinas, camping sites, market squares and similar applications and for charging stations for Vehicles Period of validity: to Translation - 13/44

14 IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Adjustable speed power drive systems Part 3: EMC requirements and specific test methods Adjustable speed power drive systems Part 5-1: Safety requirements Electrical, thermal and energy : Only for with rated voltage up to 400 V and rated current up to 16 A. No measurement of disturbance field strength. IEC ( ) EN ( ) DIN EN VDE ( ) Electromechanical elementary relays Part 1: General and safety requirements IEC ( ) EN ( ) DIN EN VDE ( ) Time relays for industrial and residential use Part 1: Requirements and Period of validity: to Translation - 14/44

15 IEC ( ) EN ( ) DIN EN VDE ( ) Power capacitors - Low-voltage power factor correction banks IEC ( ) EN ( ) DIN EN VDE ( ) Empty enclosures for low-voltage assemblies General requirements EN ( ) DIN EN DIN EN VDE ( ) Degrees of protection provided by enclosures for against external mechanical impacts (IK code) DIN VDE VDE ( ) Electronic for use in power installations : No measurement of disturbance field strength. Period of validity: to Translation - 15/44

16 DIN VDE VDE ( ) Specifications for single- and multiple cable clamps with insulating parts in power cable installations up to 1000 V DIN VDE VDE ( ) Consumer units and meter panels AC 400 V Consumer units and meter panels DIN VDE VDE ( ) Customer distribution boards and meter panels AC 400 V Main line branch terminals DIN VDE VDE ( ) Terminal blocks for connecting copper conductors Distribution terminal blocks up to 6 mm2 Period of validity: to Translation - 16/44

17 DIN VDE VDE ( ) Low-voltage assemblies Part 505: Specification for house connection boxes and fuseboxes Period of validity: to Translation - 17/44

18 IEC ( ) IEC AMD 1 ( ) EN ( ) EN 60112/A1 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) DIN EN /A1 VDE /A1 ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Method for the determination of the proof and the comparative tracking indices of solid insulating materials machinery Electrical of machines Part 1: General requirements Fire hazard testing Part 2-10: Glowing/hot-wire based test methods Glow-wire apparatus and common test procedure IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 2-11: Glowing/hot-wire based test methods Glow-wire flammability test method for end-products Period of validity: to Translation - 18/44

19 IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 2-12: Glowing/hot-wire based test methods Glow-wire flammability index (GWFI) test method for materials IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 2-13: Glowing/hot-wire based test methods Glow-wire ignitability îndex (GWIT) test method for materials IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 10-2: Abnormal heat Ball pressure test IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 11-5: Test Flames - Neddle-flame test method Apparatus, confirmatory test arrangement and guidance Period of validity: to Translation - 19/44

20 IEC ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 11-10: Test flames - 50 W horizontal and vertical flame test methods IEC ( ) IEC AMD 1 ( ) EN ( ), IDT, EN /A1 ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) EN /A11 ( ) EN /A12 ( ) EN /A13 ( ) DIN EN VDE ( ) DIN EN /A12 VDE /A12 ( ) DIN EN /A13 VDE /A13 ( ) IEC ( ) IEC AMD 1 ( ) EN ( ) DIN EN VDE ( ) Fire hazard testing Part 11-20: Test flames W flame test methods Electrical accessories Circuit breakers for overcurrent protection for household and similar installations Part 1: Circuit-breakers for a.c. operation Circuit-breakers for overcurrent protection for household and similar installations Part 2: Circuit-breakers for a.c. and d.c.operation Period of validity: to Translation - 20/44

21 IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN 60934/A1 ( ) EN 60934/A2 ( ) DIN EN VDE 0642 ( ) IEC ( ) EN ( ) DIN EN VDE ( ) IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Circuit-breakers for (CBE) Connecting devices Electrical copper conductors Safety requirements for screw-type and screwless-type clamping units Part 1:General requirements and particular requirements for clamping units for conductors 0,2 mm2 up to 35 mm2 (included) Connecting devices Electrical copper conductors Safety requirements for screw-type and screwless-type clamping units Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) Residual current operated circuitbreakers without integral overcurrent protection for household and similar uses (RCCB s) Part 1: General rules Period of validity: to Translation - 21/44

22 IEC ( ) EN ( ) DIN EN VDE ( ) Residual current operated circuitbreakers without integral overcurrent protection for household and similar uses (RCCB s) Part 2-1: Applicability of the general rules to RCCB s functionally independent of line voltage IEC ( ) EN ( ) DIN EN VDE ( ) Residual current operated circuitbreakers with integral overcurrent protection for household and similar uses (RCBO s) Part 1: General rules IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Safety requirements for for measurement, control and laboratory use - Part 1: General requirements Safety requirements for for measurement, control, and laboratory use - Part 2-201: Particular requirements for industrialprocess measurement, control and automation, specifically control (excluding functional safety) Period of validity: to Translation - 22/44

23 IEC ( ) EN ( ) DIN EN VDE ( ) Switches for appliances Part 1: General requirements IEC ( ) EN ( ) DIN EN VDE ( ) Switches for appliances Part 2-1: Particular requirements for cord switches IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A2 ( ) DIN EN VDE ( ) IEC ( ) EN ( ) DIN EN VDE ( ) Electromechanical contactors for household and similar purposes Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements Period of validity: to Translation - 23/44

24 IEC ( ) EN ( ) DIN EN VDE ( ) Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) IEC ( ) IEC AMD 1 ( ) EN ( ) EN 62019/A1 ( ) EN 62019/A11 ( ) DIN EN VDE 0640 ( ) EN ( ) EN 62262/A1 ( ) DIN EN DIN EN VDE ( ) DIN EN 50102/A1 DIN EN 62262/A1 VDE /A1 ( ) DIN VDE VDE ( ) Electrical accessories Circuit-breakers and similar for household use Auxiliary contact units Degrees of protection provided by enclosures for against external mechanical impacts (IK code) Residual current operated circuitbreakers without integral overcurrent protection for household and similar uses (RCCBs) Part 101: Applicability of the general rules to RCCBs for rated voltage exceeding 440 V AC or rated current exceeding 125 A Period of validity: to Translation - 24/44

25 BGI 526 ZH 1/44 ( ) Evaluation of the accessibility of components Period of validity: to Translation - 25/44

26 EMC - Electromagnetic compatibility EMC IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) Electromagnetic compatibility (EMC) Part 3-2: Limits Limits for harmonic current emissions ( input current < 16 A per phase) : No restrictions DIN EN VDE ( ) EMC IEC ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems, for with rated current < 16 A per phase and not subject to conditional connection : No restrictions EMC IEC ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-2: Testing and measuring techniques Electrostatic discharge immunity test : No restrictions Period of validity: to Translation - 26/44

27 EMC IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) EMC IEC ( ) IEC Corr 1 ( ) IEC Corr 2 ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) EMC IEC ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-3: Testing and measuring techniques Radiated, radio-frequency electromagnetic field immunity test Electromagnetic compatibility (EMC) Part 4-4: Testing and measuring techniques Electrical fast transient/burst immunity test Electromagnetic compatibility (EMC) Part 4-5: Testing and measuring techniques Surge immunity test : Up to 1 GHz amplifier power suitable for test level 3 (10 V/m) at 2 m distance at maximum. Size of homogeneous field 0.5 m x 0.5 m at f = MHz. Size of homogeneous field 1 m x 1 m at f = MHz. : No restrictions : No restrictions Period of validity: to Translation - 27/44

28 EMC IEC ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-6: Testing and measuring techniques Immunity to conducted disturbances, induced by radio-frequency fields : Up to 100 MHz amplifier power suitable for test level 3 (10V). EMC IEC ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-11: Testing and measuring techniques Voltage dips, short interruptions and voltage variations immunity : No restrictions EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) EMC IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-13: Testing and measurement techniques Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity Electromagnetic compatibility (EMC) Part 4-14: Testing and measurement techniques Voltage fluctuation immunity test for with input current not exceeding 16 A per phase : No restrictions : No restrictions Period of validity: to Translation - 28/44

29 EMC IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) DIN EN /A2 VDE /A2 ( ) EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) EMC IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A1 ( ) EN /A2 ( ) DIN EN VDE ( ) EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 4-17: Testing and measurement techniques Ripple on d.c. input power port immunity test Electromagnetic compatibility (EMC) Part 4-27: Testing and measurement techniques Unbalance, immunity test for with input current not exceeding 16 A per phase Electromagnetic compatibility (EMC) Part 4-28: Testing and measurement techniques Variation of power frequency, immunity test for with input current not exceeding 16 A per phase Electromagnetic compatibility (EMC) Part 4-29: Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c. input power port immunity : No restrictions : No restrictions : No restrictions : No restrictions Period of validity: to Translation - 29/44

30 EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 6-1: Generic standards Immunity for residential, commercial and light-industrial environments : Up to 1 GHz amplifier power suitable for test level 3 (10 V/m) at 2 m distance at maximum. Size of homogeneous field 0.5 m x 0.5 m at f = MHz. Size of homogeneous field 1 m x 1 m at f = MHz. Test according to EN will be subcontracted. Period of validity: to Translation - 30/44

31 EMC CISPR 11 ( ) CISPR 11 AMD 1 ( ) EN ( ) EN 55011/A1 ( ) DIN EN VDE ( ) EMC CISPR 22 ( ) EN ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environments Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments : Up to 1 GHz amplifier power suitable for test level 3 (10 V/m) at 2 m distance at maximum. Size of homogeneous field 0.5 m x 0.5 m at f = MHz. Size of homogeneous field 1 m x 1 m at f = MHz. EMC : Only conducted emission can be performed in accordance with the standard. EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) Electromagnetic compatibility (EMC) Part 6-4: Generic standards Emission standard for industrial environments EMC : Only conducted emission can be performed in accordance with the standard. Period of validity: to Translation - 31/44

32 EMC IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN VDE ( ) EMC CISPR 11 ( ) CISPR 11 AMD 1 ( ) EN ( ) EN 55011/A1 ( ) DIN EN VDE ( ) Industrial, scientific and medical Radio disturbance characteristics Limits and methods of measurement Information technology Radio disturbance characteristics Limits and methods of measurement EMC : Only conducted emission can be performed in accordance with the standard. EMC : Only conducted emission can be performed in accordance with the standard. Period of validity: to Translation - 32/44

33 IEC ( ) EN ( ) DIN EN ( ) testing Part 1: General and guidance IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-1: Tests Tests A: Cold IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-2: Tests Tests B: Dry heat IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-6: Tests Test Fc: Vibration (sinusoidal) Period of validity: to Translation - 33/44

34 IEC (1981) EN ( ) DIN EN ( ) testing Part 2-11: Tests Test Ka: Salt mist IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-24: Tests Test N: Change of temperature IEC ( ) EN ( ) DIN EN ( testing Part 2-18: Tests Test R and guidance: Water IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-27: Tests Test Ea and guidance: Shock Period of validity: to Translation - 34/44

35 IEC (1987) EN ( ) DIN EN ( ) testing Part 2-29: Tests Test Eb and guidance: Bump IEC ( ) EN ( ) DIN EN ( ) testing Part 2-30: Tests Test Db and guidance: Damp heat, cyclic ( hour cycle) IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-31: Tests Test Ec: Rough handling shocks, primarily for -type specimens IEC (1975) IEC AMD 1 (1982) IEC AMD 2 ( ) EN ( ) testing Part 2-32: Tests Test Ed: Free fall DIN EN ( ) Period of validity: to Translation - 35/44

36 IEC (1971) IEC AMD 1 (1978) EN ( ) DIN EN ( ) testing Part 2-33: Guidance on change of temperature IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-38: Tests Test Z/AD: Composite temperature/humidity cyclic test IEC (1980) IEC AMD 1 ( ) EN ( ) DIN EN ( testing Part 2-45: Tests Test XA and guidance: Immersion in cleaning solvents IEC ( ) EN ( ) DIN EN ( ) testing Part 2-47: Tests Mounting of components, and other articles for vibration, impact and similar dynamic Period of validity: to Translation - 36/44

37 IEC (1982) EN ( ) DIN EN ( ) testing Part 2-48: Tests Guidance on the application of the of IEC to simulate the effects of storage IEC ( ) EN ( ) DIN EN ( ) testing Part 2-52: Tests Test Kb: Salt mist, cyclic (sodium chloride solution) IEC ( ) EN ( ) DIN EN ( ) testing Part 2-61: Tests Test Z/ABDM: Climatic sequence IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 2-64: Tests Test Fh: Vibration, broad-band random (digital control) and guidance Period of validity: to Translation - 37/44

38 IEC ( ) EN ( ) DIN EN ( ) testing Part 2-67: Tests Test Cy: Damp heat, steady state, accelerated test primarily intended for components IEC ( ) EN ( ) DIN EN ( ) testing Part 2-70: Tests Test Xb: Abrasion of markings and letterings caused by rubbing of fingers and hands IEC ( ) EN ( ) DIN EN ( ) testing Part 2-75: Tests Test Eh: Hammer IEC ( ) EN ( ) DIN EN ( ) testing Part 2-78: Tests Test Cab: Damp heat, steady state Period of validity: to Translation - 38/44

39 IEC ( ) EN ( ) DIN EN VDE ( ) testing Part 3-1: Background information Cold and dry heat IEC ( ) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A2 ( ) DIN EN ( ) IEC (1982) IEC AMD 1 (1987) DIN IEC ( ) Classification of environmental conditions Part 1: parameters and their severities Electrical engineering Classification of environmental conditions Part 2: conditions appearing in nature Temperature and humidity IEC ( ) EN ( ) DIN IEC ( ) Electrical engineering Classification of environmental conditions Part 2: conditions appearing in nature Precipitation and wind Period of validity: to Translation - 39/44

40 IEC (1984) IEC AMD 1 (1987) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Introduction IEC ( ) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 1: Storage IEC ( ) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 2: Transportation IEC ( ) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 3: Stationary use at weatherprotected locations Period of validity: to Translation - 40/44

41 IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN ( ) DIN EN /A1 ( IEC ( ) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 4: Stationary use at notweatherprotected locations Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 5: Ground vehicle installations IEC (1987) IEC AMD 1 ( ) IEC AMD 2 ( ) EN ( ) EN /A2 ( ) DIN EN ( ) DIN EN /A2 ( ) IEC ( ) EN ( ) DIN EN ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 6: Ship environment Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 7: Portable and nonstationary use Period of validity: to Translation - 41/44

42 IEC ( ) IEC AMD 1 ( ) EN ( ) EN /A1 ( ) DIN EN ( ) DIN EN /A1 ( ) ISO ( ) EN ISO ( ) DIN EN ISO ( ) Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 9: Microclimates inside products Paints and varnishes Determination of resistance to humidity Part 2: Procedure for exposing test specimens in condensationwater atmospheres ISO 6988 ( ) EN ISO 6988 ( ) DIN EN ISO 6988 ( ) Metallic and other non-organic coatings Sulfur dioxide test with general condensation of moisture ISO 9227 ( ) EN ISO 9227 ( ) DIN EN ISO 9227 ( ) Corrosion in artificial atmospheres Salt spray Period of validity: to Translation - 42/44

43 ISO ( ) EN ISO ( ) DIN EN ISO ( ) Methods for corrosion testing of metallic and other inorganic coatings on metallic substrates - Rating of test specimens and manufactured articles subjected to corrosion ISO ( ) Road vehicles - Degrees of protection (IP-Code) - Protection of against foreign objects, water and access IEC ( ) DIN ( ) Road vehicles Degrees of protection (IP-code) Protection against foreign objects, water and contact Electrical DIN ( ) Testing in a saturated atmosphere in the presence of sulfur dioxide Period of validity: to Translation - 43/44

44 Technical responsibility for the test reports: Herr Ralf Hartkamp Herr Klaus Heidelberger Herr Toni Hoffmann Herr Heribert Schorn Period of validity: to Translation - 44/44

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12095-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2015-07-16 to 2019-03-06 Holder of certificate: Weidmüller

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11321-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.12.2016 to 19.12.2021 Holder of certificate: TÜV

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 19102 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.09.2013 to 02.09.2018 Holder of certificate: AUCOTEAM

More information

ENVIRONMENTAL TESTING

ENVIRONMENTAL TESTING ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11272-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 18.10.2017 to 17.10.2022 Holder of certificate: VDZ

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-18869-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 30.08.2013 to 29.08.2018 Holder of certificate: ilf

More information

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11068-09-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 10.07.2014 to 09.07.2019 Holder of certificate: Karlsruher

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate DPL110551000 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20140612 to 20160711 Date of issue: 20140612 Holder of

More information

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme) Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Stratford Road Solihull West Midlands B90 4GW Contact: Mr C Gregory Tel: +44 (0)121 627 3225 Fax: +44 (0)121 627 4353 E-Mail: colin.gregory@trw.com Website:

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Electric vehicle charging system

Electric vehicle charging system TECHNICAL REFERENCE (ICS 43.120) TECHNICAL REFERENCE FOR Electric vehicle charging system Published by SPRING Singapore 2 Bukit Merah Central Singapore 159835 SPRING Singapore Website: www.spring.gov.sg

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.

More information

Electric Vehicle Conductive AC Charging System

Electric Vehicle Conductive AC Charging System AUTOMOTIVE INDUSTRY STANDARD Electric Vehicle Conductive AC Charging System PRINTED BY THE AUTOMOTIVE RESEARCH ASSOCIATION OF INDIA P.B. NO. 832, PUNE 411 004 ON BEHALF OF AUTOMOTIVE INDUSTRY STANDARDS

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20575-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2018-03-05 to 2021-07-28 Holder of certificate: innogy

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11238 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 09.02.2016 to 08.02.2021 Holder of certificate: ContiTech

More information

E-15 Uninterruptible Power Systems (UPS)

E-15 Uninterruptible Power Systems (UPS) Guideline No.E-15 (201705) E-15 Uninterruptible Power Systems (UPS) Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,

More information

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society Guideline No.: E-04(201510) E-04 GENERATORS Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

E-15 Uninterruptible Power Systems (UPS)

E-15 Uninterruptible Power Systems (UPS) Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,

More information

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society Guideline No.: E-04(201610) E-04 GENERATORS Issued date: October 28,2016 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection

More information

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Menu. Home About this portal Latest updates. Print Save  Resource detail Citations. Table of Contents Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7176-21 Second edition 2009-04-01 Wheelchairs Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Unit 1 Quatro Park Paycocke Road Basildon Essex SS14 3GH Contact: Mr E Martin Tel: +44 (0)1268 290115 Fax: +44 (0)1268 290123 E-Mail: eamonn.martin@mira.co.uk

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 4: Climatic loads

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 4: Climatic loads INTERNATIONAL STANDARD ISO 16750-4 First edition 2003-12-15 Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 4: Climatic loads Véhicules routiers Spécifications

More information

News from IEC Standardization of Environmental Conditions and Tests

News from IEC Standardization of Environmental Conditions and Tests Conditions and Tests Technical Advisory Board Meeting Climatic and Atmospheric Pollution Effects on Materials and Equipment Rue des Petits Carmes, 20 1000 Brusssels Hermann Ruoss 12. February 2009 Seite:

More information

Technical specifications

Technical specifications Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith

More information

Three-Phase Soft Starters

Three-Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Electrical network protection VIP30, VIP35. User s manual 12/2008

Electrical network protection VIP30, VIP35. User s manual 12/2008 Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become

More information

Single & Three-Phase Soft Starters

Single & Three-Phase Soft Starters Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK High Post Contact: Enquiries +44 (0)1722 411611 Salisbury Tel: +44 (0)1722 428739 Wiltshire Fax: +44 (0)1722 428794 SP4 6AS E-Mail: ian.callender@chemringcm.com

More information

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,6-9A,1N/O+1N/C Partno. ZE-9 Articleno. 014708 CatalogNo. XTOM009AC1 Product range ZE overload relays for mini contactor relays Phase-failure sensitivity IEC/EN 60947, VDE

More information

Protection and control VIP30, VIP35. Relays technical manual

Protection and control VIP30, VIP35. Relays technical manual Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly

More information

Step 1: Collection of required data

Step 1: Collection of required data Step 1: Collection of required data If the relevant parameters of the interfaces are known, it is possible to dimension ASSEMBLIES 3 Installation and environmental conditions 4 Operating and servicing

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Bldg 3, Rm RM6 Contact: Gareth Williams Environmental Test Centre Tel: +44 (0)1702 383589 MoD Shoeburyness Fax: +44 (0)1702 383037 Southend-on-Sea

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17435-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.12.2017 to 08.12.2018 Holder of certificate: k3works

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society Guideline No.: E-07(201610) E-07 TRANSFORMERS Issued date: October 28,2016 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

IEC TC SC E 22 F G H (UPS) A 77 B C khz 77A JIS C , A B JIS C JIS C 2136 (1/8)

IEC TC SC E 22 F G H (UPS) A 77 B C khz 77A JIS C , A B JIS C JIS C 2136 (1/8) 2 15 22 77 85 112 27 11 12 () 1 1 IEC TC SC 2 2 15 15 22 E 22 F G H (UPS) 77 A 77 B C 85 85 112 112 JIS JIS 2 2 22 77A JIS C 61000-4-16, -34 77B JIS C 61000-4-6 112 JIS C 2136 4 16 150 khz 4-34 16 A 4-6

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR 3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR www.kraus.com www.kraus.com KRAUS RAILWAY TECHNOLOGY PRODUCT LINE Pantograph Switches Trackside Disconnectors Disconnectors & Earthing Switches Pneumatic Interlock

More information

Issue Title Remarks. Instrument transformers See IEC 61869

Issue Title Remarks. Instrument transformers See IEC 61869 357 Appendix Norms and Standards As far as norms and standards are mentioned in this book, the respective citation of IEC or DIN EN is given. If IEC-standards or DIN EN-norms are not available, the European

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

NFC. (Varistor Type NFC)

NFC. (Varistor Type NFC) NFC (Varistor Type NFC) Type NFC Varistors are made of semiconductor ceramic materials composed mainly of zinc oxide. They have nonlinear resistance that changes as a function of applied voltage. It has

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Larry Brooks (QA Manager) Phone: 630 495 9770 ext. 166 Email: lbrooks@elitetest.com

More information

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist Industrial plug-in connectors HEAVYCON EVO efficient at a twist of the wrist For more efficiency in your system HEAVYCON EVO Heavy-duty plug-in connectors are established on the market and are used in

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

MITRAS MATERIALS GMBH

MITRAS MATERIALS GMBH MITRAS MATERIALS GMBH Friedrich-Ochs-Str. 2 92637 Weiden/Opf. Tel.: 0961 / 89-810 / 89-812 Fax: 0961 / 89-672 Directory of services L a b o r a t o r y MITRAS MATERIALS GMBH Edition 02/18 Rev. 08 page

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

Solid State Relays contactor with Integrated Fuse Type RGC1F

Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC

More information

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices) DATASHEET - EMS-RO-T-9-SWD-ADP Reversing starter 9A with SmartWire-DT Part no. EMS-RO-T-9-SWD-ADP Catalog No. 172763 Eaton Catalog No. EMS-RO-T-9-SWD-ADP EL-Nummer 4110026 (Norway) Delivery program Product

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,24-40A,1N/O+1N/C Partno. ZB65-40 Articleno. 278458 CatalogNo. XTOB040DC1 Product range Overload relay ZB up to 150 A Frame size ZB65 Phase-failure sensitivity IEC/EN 60947,

More information

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17435-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 30.09.2016 to 08.12.2018 Holder of certificate: k3works

More information

Draft ETSI EN V2.3.7 ( )

Draft ETSI EN V2.3.7 ( ) Draft EN 300 019-2-3 V2.3.7 (2015-09) EUROPEAN STANDARD Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-19065-04-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2017-05-11 to 2022-05-10 Date of issue: 2017-05-11

More information

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm) Contactelement,1N/C,frontmount,6.contact,screwconnection Partno. M22-K01 Articleno. 216378 CatalogNo. M22-K01Q Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

More information

ZS4-SF1 Screw Clamp Terminal Block

ZS4-SF1 Screw Clamp Terminal Block Technical Datasheet 1SNK 161 011 D0201 ZS4-SF1 Screw Clamp Terminal Block Fuse Catalogue Page 1SNK 161 011 S0201 4 mm² 10 AWG 8 mm 0.315 in Spacing Features and Benefits 90 90 180 59.7 2.35" - Protect

More information

GB/T Translated English of Chinese Standard: GB/T

GB/T Translated English of Chinese Standard: GB/T Translated English of Chinese Standard: GB/T18487.1-2015 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 43.040.99 T 35 GB/T 18487.1-2015 Replacing

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11140 18 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.11.2014 to 05.11.2019 Holder of certificate: Fraunhofer

More information

QC/T Translated English of Chinese Standard: QC/T AUTOMOTIVE INDUSTRY STANDARD

QC/T Translated English of Chinese Standard: QC/T AUTOMOTIVE INDUSTRY STANDARD QC/T 198- Translated English of Chinese Standard: QC/T198- www.chinesestandard.net Sales@ChineseStandard.net QC ICS 43.040.10 AUTOMOTIVE INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA T 36 QC/T 198-

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-18869-01-00 according to DIN EN ISO/IEC 17025:2005 Holder of certificate: ilf Forschungs- und Entwicklungsgesellschaft Lacke

More information

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. In case of mains or unit failure the DC UPS function enables

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

Clause Measurement/testing Testing / measuring equipment / material needed Subcontracting. 3 General requirements None -

Clause Measurement/testing Testing / measuring equipment / material needed Subcontracting. 3 General requirements None - IECEE OD-5003-1:2015 IEC 2015 1 TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING, Edition 5.0 Automatic electrical controls Part 1: General requirements POVISIONAL equired S May be subcontracted, see

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3112:2011 AS/NZS 3112:2011 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets AS/NZS 3112:2011 This Joint Australian/New Zealand Standard was prepared by Joint

More information

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16 Product Name: TMAP Part Number: CPF00002 Drawing Number: CPFJ0002 Page 1 of 16 CONTENTS 1. General Data 1.1. Description 1.2. Installation Guide 1.3. Maximum ratings of pressure sensor 1.4. Operating characteristics

More information

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1 pplication description EN Emergency-off application Manual motor starter MS116/MS132 Undervoltage release U1 The emergency-off application allows machine and job safety for nominal currents up to 32 all

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

Safety Standards. Model Number:

Safety Standards. Model Number: Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,

More information

PROXIMITY DETECTION. AA Coutinho Acting Director Mine Safety

PROXIMITY DETECTION. AA Coutinho Acting Director Mine Safety PROXIMITY DETECTION AA Coutinho Acting Director Mine Safety Contents Background Accident Statistics Proximity detection devices Regulations 27 February 2017 Levels of control Regulations to be promulgated

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Actuator LA35. Data sheet LINAK.COM/TECHLINE

Actuator LA35. Data sheet LINAK.COM/TECHLINE Actuator LA35 Data sheet LINAK.COM/TECHLINE LA35 The LA35 is a very quiet and powerful actuator, and provides a practical and cost-effective solution with low power consumption. The actuator is designed

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 18438 02 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 11.03.2014 to 10.03.2019 Holder of certificate: Jürgen

More information

ZE motor-protective relay Overload monitoring of EEx e motors

ZE motor-protective relay Overload monitoring of EEx e motors Building Automation Industrial Automation Systems Hardware and Engineering ZE motor-protective relay Overload monitoring of EEx e motors 0/0 AWB300-5GB A Think future. Switch to green. All brand and product

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Stephen Laya (QA Manager) Phone: 630 495 9770 ext. 119 Email: sglaya@elitetest.com

More information

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20658-01-00 according to ISO/IEC 17025:2005 Period of validity: 13.06.2018 to 12.06.2023 Holder of certificate: IMAT Shenyang

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60269-1 Edition 3.1 2005-04 Edition 3:1998 consolidated with amendment 1:2005 Low-voltage fuses Part 1: General requirements IEC 2005 Copyright - all rights reserved No part

More information