Tintometer -Group. Comparator Highlights. The system for colorimetric water analysis

Size: px
Start display at page:

Download "Tintometer -Group. Comparator Highlights. The system for colorimetric water analysis"

Transcription

1 Tintometer -Group Highlights More than 400 different test discs are available Compensation for coloured and turbid samples Guaranteed constancy of the coloured glass standards Integrated prism The system for colorimetric water analysis 22 Regularly updated information: General Catalogue July 2009

2 With its accessories, the Lovibond Comparator system 2000 is an extremely versatile, modular system for testing water. It is simple to use yet is uncompromising in terms of precision and reproducibility of results. It is compact and portable. The integrated prism brings the glass standards of the test discs and the coloured sample into the same field of view. Test discs The required accuracy of results is only ensured if stable, fade-free colour standards are used. Glass colour standards are fade-free, resistant to chemicals and scratchproof. Lovibond standards are made from coloured glass filters. They comply with international standards, e.g. ISO 7393/2. Please see the table on page 26 for information on the various test discs or refer to our L 213 test disc catalogue. Lighting unit We recommend the use of the battery-operated Lovibond lighting unit in variable lighting conditions. This guarantees uniform lighting conditions, and ensures greater test accuracy. Cells We manufacture precision plastic and optical glass cells in line with the highest quality standards. The cells ensure high precision and reproducibility of results. Test disc with colour-stable glass standards Comparator System 2000 Lighting unit TK 102 Nessleriser 2150 with lighting unit Order codes see page 27 Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing General Catalogue July

3 Tintometer -Group Testpak Ideal add-on for the For the most popular tests, discs are available in a Lovibond TESTPAK. The TESTPAK is a simple and cost-effective means of extending the use of an existing Comparator instrument to a new test parameter. Each TESTPAK contains the required test disc, tablet reagents (normally for 100 tests), cells and accessories as well as detailed instructions for the desired method. Please contact our sales departments for further information: sales@tintometer.de TESTPAK with test disc, tablet reagents, cells, accessories and instructions Test Disc Range* Code Aluminium 3 / 127 A mg / l Ammonia 3 / mg / l NH / mg / l N / mg / l N Bromine 3 / 53 A mg / l / 53 B mg / l / 53 C mg / l Chlorine 3 / 40 A mg / l (free, combined, total) 3 / 40 B mg / l / 40 HN mg / l / 40 J mg / l / 40 K mg / l / 40 P mg / l / 40 S mg / l Chlorine Dioxide 3 / 40 ED mg / l / 40 FD mg / l Copper 3 / mg / l / mg / l / mg / l Hydrogen Peroxide, DPD 3 / 50 E mg / l DPD 3 / 50 A mg / l DPD 3 / 50 B mg / l Potassium iodide 3 / mg / l Potassium iodide 3 / mg / l Iron 3 / mg / l / mg / l Nitrite 3 / mg / l Ozone DPD 3 / 67 A mg / l DPD 3 / mg / l Indigo 3 / mg / l ph-value 2 / 1 G / 1 J / 1 L QAC (Quaternary 3 / mg / l Ammonium Compounds) 3 / mg / l Sodium Hypochlorite 3 / 2 Hypo 2 18 % Zinc 3/ mg/l * Disc readings see following pages 24 Regularly updated information: General Catalogue July 2009

4 Test Kits Complete kits for water analysis Scope of delivery for standard kits Comparator test kits are supplied as a complete system in a sturdy plastic case. Together with the and test discs, each kit includes all the necessary cells, accessories and Lovibond tablet reagents (for 100 measurements) to achieve reliable results. The table to the right shows a selection of the most popular standard test kits. Customised equipment In addition to supplying standard test kits, we can construct customised kits to suit individual requirements. Based on the desired test parameters and measuring ranges we will draw up a detailed offer to suit your application. Optional accessory All test kit versions allow integration of the battery-operated portable lighting unit TK 102 and charger TK 102/ 1. Operating instructions The operating instructions provide a step-by-step explanation of how to conduct the water test, ensuring that even "non-chemists can achieve reliable and accurate measurements in the minimum of time. Example of a comparator test kit, together with daylight unit Type Designation/Combi Test Range* Code AF 270 Mini Lab Aluminium mg/l Al Pool Water Ammonia mg/l N Chlorine mg/l Cl mg/l Cl 2 Chloride mg/l Cl Cyanuric acid 0-80 mg/l Iron ph-value mg/l Fe ph ph Total Alkalinity mg/l CaCO 3 Sulphate mg/l SO 4 AF 357 Drinking Water Chloride (salinity) mg/l Cl Chlorine mg/l Cl mg/l Cl 2 Hardness Total mg/l CaCO 3 Fluoride Hazen Colour mg/l F mg/l Pt ph-value ph AF 358 Sewage and Ammonia 0-1 mg/l N Domestic Effluents Chlorine mg/l Cl mg/l Cl 2 Nitrite mg/l N Permanganate (BOD) 0-60 mg/l ph-value 4-8 ; ph Sulphide mg/l S AF 368 Mini Lab Chromium µg Cr Heavy Metals Copper µg Cu Cyanide mg/l Cn Nickel 1-10 mg/l Ni Zinc 0-50 µg Zn Type Designation/Single Test Range* Code AF 274 Amine Amine 1-10 mg/l AF 112A Chlorine free, comb. tot. Chlorine mg/l Cl AF 112B Chlorine free, comb. tot. Chlorine mg/l Cl AF 112E Chlorine free, comb. tot. Chlorine mg/l Cl AF 112E/F Chlorine free, comb. tot. Chlorine mg/l Cl Chlorine mg/l Cl 2 AF 112J/J Chlorine free, comb. tot. Chlorine mg/l Cl ph-value ph AF 112N/T Chlorine free, comb. tot. Chlorine mg/l Cl Chlorine mg/l Cl 2 AF 112ED Chlorine dioxide Chlorine dioxide mg/lclo AF 112 Chlorine dioxide Chlorine dioxide mg/lclo EF/ED AF 116A Chlorine, ph Chlorine mg/l Cl ph-value ph AF 116B Chlorine, ph Chlorine mg/l Cl ph-value ph AF 118S Chlorine, ph Chlorine mg/l Cl ph-value ph AF 139 Sodium hypochlorite Sodium hypochlorite 2-18 % NaOCl AF 129 Water Balance * Disc readings see following pages Comparator System 2000 General Catalogue July

5 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Aluminium 3/127 A 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l Amine 3/58 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l /64 0; 0.25; 0.5; 1; 2 mg/l 0-2 mg/l Ammonia 3/112 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4 mg/l mg/l NH /113 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l N /125 0; 1; 2; 3; 4; 5; 6; 8; 10 mg/l 0-10 mg/l N NAA 1; 2; 3; 4; 5; 6; 8; 10 µg 1-10 µg NH NAB 10; 12; 14; 16; 18; 20; 22; 24; 26 µg µg NH NAC 28; 32; 36; 40; 44; 48; 52; 56; 60 µg µg NH NAD 60; 65; 70; 75; 80; 85; 90; 95; 100 µg µg NH and Accessories Type Item Code TK 100 Lovibond TK 102 Portable lighting unit, battery operated Daylight Unit 2000, mains operated AF 631 Water sampler with two 500 ml bottles and one lid DB 426 Cell stand for 10 cells-13.5 mm, path length Glass stirring rod, 12 cm length Plastic stirring rod, 13 cm length Brush, 11 cm length Glass Cells Type Item Code DB424/S 5 glass cells, 13.5 mm path length, calibrated at 2 12 ml, with lids W 680/40 Glass cell 40 mm path length, calibrated at 20 ml Plastic Cells 5 plastic cells, frosted on two sides, mm path length, volume 10 ml, with lid 10 plastic cells, as plastic cells, as Glass cell with lid, volume 10 ml, calibrated 2-12 ml, path length 13,5 mm, Pack of 5, code: Regularly updated information: General Catalogue July 2009

6 Reagents Quantity Code Accessories Code ALUMINIUM No mm cell, 10ml ALUMINIUM No Combi pack # each ALUMINIUM No.1 / No.2 each AMINE Extraction tube AF Details on request 13.5 mm cell, 10ml AMMONIA No mm cell W680/ AMMONIA No Combi pack # each AMMONIA No.1 / No.2 each AMMONIA No.1/ mm cell, 10ml Comparator System 2000 AMMONIA No.1/2 5 mm cell W NESSLER reagent 30 ml Nessler tubes 113 mm ml SEIGNETTE salt solution 100 ml NESSLER reagent Nessler tubes 113 mm SEIGNETTE salt solution NESSLER reagent Nessler tubes 113 mm SEIGNETTE salt solution NESSLER reagent Nessler tubes 113 mm SEIGNETTE salt solution Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm Nessleriser System and Accessories Type Item Code 2150 Nessleriser 2150 with stand, daylight unit and AF 306/P Nessleriser 2150 with stand Nessleriser 2150 upgrade kit Nessleriser 2250 with stand, daylight unit and DB Nessleriser 2250 with stand Nessleriser 2250 upgrade kit with Nessler tubes DB Daylight 2000 lighting unit Stand for Nessleriser upgrade kit AF 306/S Stand for 12 Nessler tubes AF 306 Pair Nessler tubes, 113 mm AF 306/P Pair Nessler tubes, 113 mm with plungers Plunger for Nessler tube AF 306 and AF 306/P DB 420 Pair Nessler tubes, 250 mm with plungers Plunger for Nessler tube DB AF 315 Special Nessler tube (determination of oxygen with disc NOE) Nessleriser 2250 with lighting unit General Catalogue July

7 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Bromine 3/53A 0.2; 0.4 ; 0.6; 0.8; 1; 1.2; 1.4; 1.6; 2 mg/l mg/l /53B 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l /53C 0.5; 1; 1.5; 2; 2.5; 3; 4; 5; 6 mg/l mg/l Chlorine 3/40E 0.02; 0.04 ; 0.06; 0.08; 0.1; 0.15; 0.2; 0.25; 0.3 mg/l mg/l free, combined, total 0.02; 0.04 ; 0.06; 0.08; 0.1; 0.2; 0.3; 0.4; 0.5 mg/l mg/l /40F 0.2; 0.25 ; 0.3; 0.35; 0.4; 0.5; 0.6; 0.7; 0.8 mg/l mg/l /40G 1.5; 1.8; 2.0; 2.3; 2.5; 2.7; 3.0; 3.2; 3.5 mg/l mg/l /40A 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l /40T 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l /40N 1.1; 1.2; 1.3; 1.4; 1.5; 1.6; 1.7; 1.8; 2 mg/l mg/l /40J 0.1; 0.2; 0.3; 0.4; 0.6; 0.8; 1; 1.5; 2 mg/l mg/l /40B 0.2; 0.4; 0.6; 1; 1.5; 2; 2.5; 3; 4 mg/l mg/l /40K 0.5; 1; 1.5; 2; 2.5; 3; 4; 5; 6 mg/l mg/l /40S 1; 1.2; 1.4; 1.6; 1.8; 2; 2.5; 3; 4 mg/l mg/l /40P 2; 2.3; 2.5; 2.7; 3; 3.2; 3.6; 4; 5 mg/l mg/l /40HN 2; 3; 4; 5; 6; 7; 8; 9; 10 mg/l mg/l /40CZ 0.5; 1; 1.5; 2; 4 mg/l Cl mg/l Cl ; 7.4; 7.6; 8 ph 7-8 ph 3/2A 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l /2AB 0.15; 0.25; 0.5; 0.75; 1; 1.25; 1.5; 1.75; 2 mg/l mg/l /2APC 1; 1.5; 2; 2.5; 3; 3.5; 4; 4.5; 5 mg/l mg/l Regularly updated information: General Catalogue July 2009

8 Reagents Quantity Code Accessories Code DPD No BT 13.5 mm cell, 10ml BT BT DPD No mm cell, 10ml DPD No mm cell, 10ml DPD No BT 40 mm cell W680/ BT BT DPD No DPD No BT BT BT Combi pack # each DPD No.1 / No.3 each DPD No BT BT BT DPD No.1/2/3/4 40 mm cell W680/ DPD No.1/2/3/4 40 mm cell W680/ DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/4 25 mm cell W680/ mm cell, 10ml DPD No.1/2/3/4 25 mm cell W680/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/4 5 mm cell W680/ DPD No.1/2/3/ mm cell 10ml Phenol red tablets, see ph determination 13.5 mm cell 10ml Reagents at specialized chemistry dealer 13.5 mm cell 10ml Reagents at specialized chemistry dealer 13.5 mm cell 10ml Reagents at specialized chemistry dealer 5 mm cell W680/ Tablet reagents in foil blister strip (BT) Comparator System 2000 Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm General Catalogue July

9 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Chlorine HR 3/2APH 2; 3; 4; 5; 6; 7; 8; 9; 10 mg/l total Cl mg/l total chlorine only 3/2ARP 5; 10; 15; 20; 25; 30; 35; 40; 50 mg/l total Cl mg/l /2IOD 5; 10; 25; 50; 75; 100; 150; 200; 250 mg/l total Cl mg/l Chlorine NDPB 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.1 mg/l mg/l free, combined, total NDPC 0.02; 0.04; 0.06; 0.08; 0.1; 0.12; 0.14; 0.16; 0.2 mg/l mg/l NDP 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.5 mg/l mg/l NDPD 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l Chlorine dioxide 3/40AD 0.19; 0.38; 0.57; 0.76; 0.95; 1.14; 1.33; 1.52; 1.9 mg/l mg/l /40ED 0.04; 0.08; 0.11; 0.15; 0.19; 0.28; 0.38; 0.48; 0.57 mg/l mg/l /40FD 0.38; 0.48; 0.57; 0.66; 0.76; 0.95; 1.14; 1.33; 1.52 mg/l mg/l / ; 0.5; 0.75; 1; 1.25; 1.5; 2; 3; 5 mg/l mg/l Chromium 3/59 10; 20; 30; 40; 50; 60; 70; 80; 100 µg µg Copper 3/106 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l /110 0; 0.5; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l mg/l DEHA 3/150 8; 16; 24; 32; 40; 48; 56; 64; 80 µg/l µg Disc reading should be multiplied by 2 for true DEHA concentration 30 Regularly updated information: General Catalogue July 2009

10 Reagents Quantity Code Accessories Code CHLORINE HR (KI) mm cell W680/ ACIDIFYING GP Combi pack # each CHLORINE HR (KI)/ each ACIDIFYING GP CHLORINE HR (KI) 13.5 mm cell 10ml ACIDIFYING GP CHLORINE HR (KI) 13.5 mm cell 10ml ACIDIFYING GP DPD No.1 NESSLERISER Nessleriser Nessler tubes 113 mm DPD No.2 NESSLERISER DPD No.3 NESSLERISER DPD No.4 NESSLERISER DPD No.1/2/3/4 NESSLERISER Nessleriser Nessler tubes 113 mm DPD No.1/2/3/4 NESSLERISER Nessleriser Nessler tubes 113 mm DPD No.1/2/3/4 NESSLERISER Nessleriser Nessler tubes 113 mm DPD No BT 13.5 mm cell, 10 ml BT DPD No.1 40 mm cell W680/ DPD No.1 40 mm cell W680/ CHLORINE HR (KI) mm cell W680/ ACIDIFYING GP Combi pack # each CHLORINE HR (KI)/ each ACIDIFYING GP Details on request 13.5 mm cell, 10 ml COPPER/ZINC LR mm cell, 10 ml COPPER/ZINC HR mm cell, 10 ml DEHA mm cell W680/ DEHA solution 100 ml Test disc Comparator System 2000 Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm General Catalogue July

11 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Fluoride NOM 0; 0.2; 0.4; 0.6; 0.8; 1; 1.2; 1.4; 1.6 mg/l mg/l Hardness total 4/38 0; 5; 10; 15; 20; 25; 30; 40; 60 mg/l 0-60 mg/l CaCO Hazen/APHA 4/28 50; 75; 100; 150; 200; 250; 300; 400; 500 mg Pt/l mg/l Pt NSH 10; 20; 30; 40; 50; 60; 70; 80; 90 mg Pt/l mg/l Pt NSB 70; 85; 100; 125; 150; 175; 200; 225; 250 mg Pt/l mg/l Pt CAA 0; 2.5; 5; 7.5; 10; 15; 20; 25; 30 mg Pt/l 0-30 mg/l Pt CAB 30; 35; 40; 45; 50; 55; 60; 65; 70 mg Pt/l mg/l Pt Hydrazine 3/126 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l / ; 0.04; 0.06; 0.08; 0.1; 0.12; 0.14; 0.16; 0.2 mg/l mg/l /85 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l NOH 0; 0.5; 1; 2; 3; 4; 6; 8; 10 µg 0-10 µg/l Hydrogen peroxide 3/50 A 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.5 mg/l mg/l /50 B 0.1; 0.2; 0.3; 0.4; 0.6; 1; 1.5; 2; 3 mg/l mg/l /50 E 0,01; 0,02; 0,03; 0,04; 0,05; 0,07; 0,09; 0,12; 0,15 mg/l 0,01-0,15 mg/l Iodine 3/77A 0.4; 0.7; 1.1; 1.4; 1.8; 2.2; 2.5; 2.9; 3.6 mg/l mg/l /77B 0.7; 1.4; 2.2; 3.6; 5.4; 7.2; 9.0; 11; 14 mg/l mg/l Iron 3/ ; 0.04; 0.06; 0.08; 0.1; 0.15; 0.2; 0.25; 0.3 mg/l mg/l total 3/ ; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l /117 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l NOL 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.10 mg/l mg/l Manganese 3/169 0; 0.5; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l 0-4 mg/l Regularly updated information: General Catalogue July 2009

12 Reagents Quantity Code Accessories Code FLUORIDE A-Z Nessleriser Nessler tubes 113 mm FLUORIDE EXCESS AL ERIOCHROME 100 Tests mm cell, 10 ml HARDNESS powder Straight colour match to sample 40 mm cell W680/ Straight colour match to sample Nessleriser Nessler tubes 113 mm Straight colour match to sample Nessleriser Nessler tubes 113 mm Straight colour match to sample Nessleriser Nessler tubes 250 mm Straight colour match to sample Nessleriser Nessler tubes 250 mm HYDRAZINE TEST powder 30 g mm cell 10 ml HYDRAZINE TEST powder 30 g mm cell W680/ p-dmab reagent 100 ml mm cell, 10 ml p-dmab reagent 100 ml Nessler tubes 113 mm HYDR. PEROXIDE LR mm cell 10 ml HYDR. PEROXIDE LR 13.5 mm cell 10 ml Comparator System 2000 HYDR. PEROXIDE LR 40 mm Küvette W680/ DPD No BT 13.5 mm cell, 10 ml BT DPD No mm cell, 10 ml IRON LR mm cell W680/ IRON LR mm cell, 10 ml IRON (II) LR IRON HR mm cell, 10 ml IRON LR + IRON (II) LR Nessleriser Nessler tubes 113 mm MANGANESE LR mm cell, 10 ml MANGANESE LR Combi pack # each MANGANESE LR 1/ each MANGANESE LR 2 Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm Nessleriser 2250 with lighting unit General Catalogue July

13 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Molybdate 3/162 0; 1; 2; 3; 4; 5; 6; 8; 10 mg/l 0-10 mg/l MoO /137 5; 10; 15; 20; 25; 30; 35; 40; 50 mg/l mg/l MoO /138 10; 20; 30; 40; 60; 80; 100; 120; 150 mg/l mg/l MoO Nitrate 3/ ; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l NO /142 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l NO Nitrite 3/ ; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.5 mg/l mg/l N NJP 0.002; 0.004; 0.006; 0.01; 0.015; 0.02; 0.03; 0.04; 0.05 mg/l mg/l N NJ 0.05; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 µg/l µg/l N Oxygen 3/165 2; 3; 4; 5; 6; 7; 8; 10; 12 mg/l mg/l NOE 0; 0.005; 0.01; 0.015; 0.03; 0.055; 0.08; 0.1; 0.12 mg/l mg/l Ozone 3/67 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l /67A 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.1 mg/l mg/l /67S 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.45 mg/l mg/l /148 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l Regularly updated information: General Catalogue July 2009

14 Reagents Quantity Code Accessories Code Details on request 40 mm cell W680/ MOLYBDATE No mm cell W680/ MOLYBDATE No Combi pack # each MOLYBDATE No.1 HR / each MOLYBDATE No.2 HR MOLYBDATE No mm cell, 10 ml MOLYBDATE No NITRATE-TEST tablets 100 (bottle) mm cell, 10 ml NITRATE Test Powder 15 g Nitrate-Test tubes NITRITE LR NITRATE No mm cell, 10 ml NITRATE No Combi pack # each Nitrate No.1 / No.2 each NITRITE LR mm cell, 10 ml NITRITE LR Nessler tubes 113 mm NITRITE ACIDIFYING 250 (bottle) Details on request Nessler tubes 113 mm DO reagent No Tests mm cell, 10 ml DO reagent No Tests DO reagent No.3 90 Tests INDIGO CARMINE 50 (bottle) Nessleriser special tubes AF DPD No BT 13.5 mm cell, 10 ml BT DPD No BT 40 mm cell W680/ BT DPD No BT 13.5 mm cell, 10 ml BT OZONE-INDIGO mm cell W680/ Lighting unit TK 102 Comparator System 2000 Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm General Catalogue July

15 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code ph value 2/1A 1.2; 1.4; 1.6; 1.8; 2.0; 2.2; 2.4; 2.6; ph /1B 2.8; 3; 3.2; 3.4; 3.6; 3.8; 4; 4.2; ph /1C 3.6; 3.8; 4; 4.2; 4.4; 4.6; 4.8; 5; ph /1E 4.4; 4.6; 4.8; 5; 5.2; 5.4; 5.6; 5.8; ph /1G 5.2; 5.4; 5.6; 5.8; 6; 6.2; 6.4; 6.6; ph /1H 6; 6.2; 6.4; 6.6; 6.8; 7; 7.2; 7.4; ph /1J 6.8; 7; 7.2; 7.4; 7.6; 7.8; 8; 8.2; ph /1K 7.2; 7.4; 7.6; 7.8; 8; 8.2; 8.4; 8.6; ph /1L 8; 8.2; 8.4; 8.6; 8.8; 9; 9.2; 9.4; ph /1P 4; 5; 6; 7; 8; 9; 9.4; 10; ph NLC 6; 6.2; 6.4; 6.6; 6.8; 7; 7.2; 7.4; ph NLF 8; 8.2; 8.4; 8.6; 8.8; 9; 9.2; 9.4; ph Phosphate 3/133 0; 0.25; 0.5; 1; 1.5; 2; 2.5; 3; 4 mg/l mg/l PO /136 0; 5; 10; 15; 20; 25; 30; 35; 40 mg/l 0-40 mg/l PO /12 0; 10; 20; 30; 40; 50; 60; 70; 80 mg/l 0-80 mg/l PO /70 0; 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l PO /60 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l PO NMD 10; 20; 30; 40; 50; 60; 70; 80; 100 µg/l µg/l PO Regularly updated information: General Catalogue July 2009

16 Reagents Quantity Code Accessories Code THYMOL BLUE mm cell, 10 ml BROMOPHENOL BLUE mm cell, 10 ml BROMOCRESOL GREEN mm cell, 10 ml METHYL RED 100 ml mm cell, 10 ml ml BROMOCRESOL PURPLE mm cell, 10 ml BROMOTHYMOL BLUE mm cell, 10 ml PHENOL RED BT 13.5 mm cell, 10 ml BT CRESOL RED mm cell, 10 ml THYMOL BLUE mm cell, 10 ml UNIVERSAL PH 25 ml mm cell, 10 ml Indicator 100 ml ml ml BROMOTHYMOL 25 ml Nessler tubes 113 mm BLUE PH Indicator 100 ml ml ml THYMOL BLUE PH 25 ml Nessler tubes 113 mm Indicator 100 ml ml ml PHOSPHATE No.1 LR mm cell, 10 ml PHOSPHATE No.2 LR Combi pack # each PHOSPHATE No.1+2 LR each PHOSPHATE HR mm cell, 10 ml Details on request 13.5 mm cell, 10 ml PHOSPHATE HR mm cell, 10 ml Vanadomolybdate 1 litre mm cell, 10 ml reagent Details on request Nessler tubes 113 mm Tablet reagents in foil blister strip (BT) Comparator System 2000 Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm General Catalogue July

17 Tintometer -Group Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code QAC (Quaternary 3/118 0; 2; 4; 6; 8; 10; 12; 15; 20 mg/l 0-20 mg/l Ammonia Compounds) 3/119 0; 20; 40; 60; 80; 100; 120; 150; 200 mg/l mg/l Silica 3/ ; 0.6; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l mg/l SiO /147 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l SiO / ; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1.0 mg/l mg/l SiO /13 2.5; 5; 7.5; 10; 12.5; 15; 17.5; 20; 25 mg/l mg/l SiO NN 1; 2; 4; 6; 8; 10; 12; 16; 20 mg/l mg/l SiO NV 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 0.9; 1.0 mg/l mg/l SiO Sodium hypochlorite 3/2 Hypo 2; 4; 6; 8; 10; 12; 14; 16 % 2-16 % Sugar 3/29A 0; 5; 10; 15; 30; 45; 60; 75; 100 mg/l mg/l Sulphide 3/128 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l S Zinc 3/151 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l /102 0; 0.5; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l mg/l Certification for Discs To allow users to demonstrate that test equipment has been assessed for conformance with accepted quality standards, Lovibond colour discs can be certified by Tintometer Group to conform to ISO If requested at the time of order, new discs are issued with a serial number and a certificate of conformance stating that the disc has satisfied the relevant inspection criteria and conforms to the requirements of the appropriate test. Depending on the requirements of the user's quality control system, used discs can be returned at regular intervals to Tintometer Group for checking and recertification. Code Type of certificate Certificate for a new test disc Certificate for a used test disc Calibration certificate for a new test disc Calibration certificate for a used test disc 38 Regularly updated information: General Catalogue July 2009

18 Reagents Quantity Code Accessories Code QAC LR mm cell W680/ QAC HR ,5 mm Küvette, 10 ml SILICA No mm cell, 10 ml SILICA No Combi pack # each SILICA No.1 / No.2 each SILICA No.1/No mm cell, 10 ml Details on request 40 mm cell W680/ Ammonia 100 ml mm cell W680/ molybdate Ammonia 100 ml Nessleriser molybdate Nessler tubes 113 mm Details on request Nessler tubes 113 mm CHLORINE HR (Kl) mm cell, 10 ml ACIDIFYING GP Combi pack # each CHLORINE HR (KI)/ each ACIDIFYING GP Details on request 5 mm cell W680/ SULPHIDE No (bottle) mm cell, 10 ml SULPHIDE No (bottle) COPPER/ZINC LR mm cell, 10 ml COPPER/ZINC LR COPPER/ZINC HR mm cell, 10 ml COPPER/ZINC HR Comparator System 2000 Tablet reagents in foil blister strip (BT) Material Safety Data Sheets: # no BT blister tablets, including stirring rod, 10 cm General Catalogue July

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water. Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing

More information

CHECKIT Comparator. with continuous colour scales. Pool & Spa Water Testing - January 2017

CHECKIT Comparator. with continuous colour scales.  Pool & Spa Water Testing - January 2017 with continuous colour scales 16 www.lovibond.com Pool & Spa Water Testing - January 2017 Front view of the with cells Test Kit in carrying case, ready to use Plastic cells, frosted on two sides, volume

More information

Water analysis, QC and more:

Water analysis, QC and more: Water analysis, QC and more: photoflex THE REAL MULTI COLORIMETER Standardized and easy-to-use Sturdy and waterproof Sophisticated and versatile Environmental Protection: Fish Farming and Surface Water:

More information

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date Last Amended on - Page 1 of 5 I. WATER 1. Potable / Drinking Temperature IS 3025 (Part 9): 1984 (RA 2006) Ambient - 50 C Turbidity IS 3025 (Part 10): 1984 (RA 2006) 1 NTU to 100 NTU Specific Conductivity

More information

ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION

ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION WATER QUALITY PRODUCTS You can t manage what you can t measure. The importance of measurement is very well recognized by the industry. However, lack of

More information

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6 Last Amended on - Page 1 of 6 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Quality Monitoring Respirable Suspended Particulate Matter Less than 10µm or PM10 IS:5182 (Part 23):2006 5-1000 µg/m3 Respirable

More information

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date Ecosteps Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh Last Amended on - Page 1 of 10 Specific Performed Method Specification Range of ing / At I. WATER 1. Potable Water/ Domestic Bore Water/ De-mineralized

More information

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9 Acidity SM 2310B 14 days - - 100 ml - - 250mL P None Alkalinity (as CaCO 3) SM 2320B 14 days NS 5 100 ml - - 250mL P None Ammonia Nitrogen SM 4500NH3-D 28 days - - 100 ml - - 250mL P H 2 SO 4 Asbestos

More information

Plate Heat Exchangers

Plate Heat Exchangers Plate Heat Exchangers General Plate heat exchangers are used wherever thermal energy (heat) has to be transferred from one fl uid to another. The advantage is that they can maintain the fl uid temperature

More information

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7. Page 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Index Aguapure 100 2 Aguapure 200 2 Lara APS 3 P-Pump 4 Aspendose 5 Tank for chemical 6 Tank with mixer 6 Glass Sensor 7 AguaCon 8 Poolsaver Tetra 10 System

More information

APPENDIX D WATER QUALITY DATA

APPENDIX D WATER QUALITY DATA APPENDIX D WATER QUALITY DATA Mr. John Keating August 9, 2002 Page 2/8 SW-4 and at the settling pond near the bulk extraction area. In addition, total and faecal coliform bacteria samples are collected

More information

10.6 Schedule of Accreditation

10.6 Schedule of Accreditation Testing Laboratory is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing and calibration laboratories

More information

TRACE ELEMENTS IN URINE. Event #3, 2012

TRACE ELEMENTS IN URINE. Event #3, 2012 TRACE ELEMENTS IN URINE Event #3, 202 November 30 th, 202 Event #3, 202 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent. Urine was collected

More information

Test papers Test strips

Test papers Test strips Dip & Read Tests Test papers Test strips Accurate Rapid Easy Dip & Read Tests for more than 40 substances ph indicators semi-quantitative tests qualitative tests MACHEREY-NAGEL Welcome MACHEREY-NAGEL is

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY SERVICES, PETROTRIN Southern Main Road Pointe-A-Pierre, Trinidad, Trinidad & Tobago Peter Bhim Phone: 868 658 4200 CHEMICAL Valid To: November 30,

More information

TRACE ELEMENTS IN URINE

TRACE ELEMENTS IN URINE TRACE ELEMENTS IN URINE Proficiency Test Report Event #1, 014 March 4 th, 014 Event #1, 014 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent.

More information

Environmental/Analytical LabCivil Engineering Lab Equipment

Environmental/Analytical LabCivil Engineering Lab Equipment DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.

More information

N E W! The next generation Digital Burette.

N E W! The next generation Digital Burette. N E W! Bottle-top Burette Easy dropwise titration, a compact, highprecision design, replaceable piston/cylinder assembly and an optional PC interface these are just some of the features of this successor

More information

Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents

Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents Current World Environment Vol. 7(1), 125-131 (2012) Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents DHANANJAY DWIVEDI 1 and

More information

To the participants of AQS Baden-Württemberg Dear Madam or Sir,

To the participants of AQS Baden-Württemberg Dear Madam or Sir, AQS Baden-Württemberg To the participants of AQS Baden-Württemberg Dr. Frank Baumeister, Dr. Michael Koch, Mandy Wünsche Bandtäle 2 70569 Stuttgart GERMANY T +49 711 685-65446 F +49 711 685-63769 info@aqsbw.de

More information

Replacement Tubes for Gillian Gas Detection Pumps

Replacement Tubes for Gillian Gas Detection Pumps 236SA S 1,1,2-Trichloroethane (10-100 ppm) 235SA S 1,1-Dichloroethane (10-160 ppm) 230SA S 1,2-Dichloroethane (5-50 ppm) 145SA S 1,2-Dichloroethylene (4.2-840 ppm) 194S S 1,3-Dichloropropane (10-500 ppm)

More information

Measuring Cells for free chlorine, chlorine dioxide, ozone

Measuring Cells for free chlorine, chlorine dioxide, ozone JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Eraring Power Station - EPA Licence Coal Unloader - EPA Licence Environmental Monitoring Data July 2016

Eraring Power Station - EPA Licence Coal Unloader - EPA Licence Environmental Monitoring Data July 2016 Eraring Power Station - EPA Licence 1429 Rocky Point Rd, Morriset NSW 2264 Coal Unloader - EPA Licence 4297 Eraring Coal Delivery Facility, Construction Rd, Dora Creek NSW 2264 Environmental Monitoring

More information

Discipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013.

Discipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013. Last Amended on - Page 1 of 7 I. FOOD & AGRICULTURAL PRODUCTS 1. Food Grains Moisture AOAC (19 th Eddition): 2012, 930.15 Total Ash AOAC (19 th Eddition): 2012, 923.03 Protein AOAC (19 th Eddition): 2012,

More information

ortable ph, Conductivity & DO2 Meters

ortable ph, Conductivity & DO2 Meters ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500

More information

4 A village survey: Mandari, Lakshmipur

4 A village survey: Mandari, Lakshmipur 115 4 A village survey: Mandari, A rapid hydrochemical survey of the mouza (village) of Mandari, District was carried out during November 1999. Arsenic in the survey was measured in a various field laboratories

More information

ASTM Methods that are feasible with Metrohm instruments

ASTM Methods that are feasible with Metrohm instruments ASTM Methods that are feasible with Metrohm instruments Automotive ASTM D5827-09 Standard test method for analysis of engine coolant for chloride and other anions by ion Biofuels a) Biodiesel ASTM D664-09

More information

Supplementary information

Supplementary information Supplementary information An Optoelectronic Nose for Detection of Toxic Gases Sung H. Lim, Liang Feng, Jonathan W. Kemling, Christopher J. Musto, Kenneth S. Suslick * Department of Chemistry, University

More information

Stamolys CA71AM. Technical Information

Stamolys CA71AM. Technical Information Technical Information Stamolys CA71AM Ammonium analyzer Compact photometric analysis system for the ammonium measurement in sewage treatment plants, in drinking water and in industrial water treatments

More information

Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette! The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10 ml, 25 ml, and 50 ml sizes, you can titrate quickly and

More information

Titrette. class A precision. 10 ml. New. size. The next generation Digital Burette!

Titrette. class A precision. 10 ml. New. size. The next generation Digital Burette! The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10, 25, and 50 sizes, you can titrate quickly and reliably

More information

HI Free Chlorine Meter

HI Free Chlorine Meter Instruction Manual HI 95762 Free Chlorine Meter for Drinking Water Application www.hannacan.com This Instrument is in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna product.

More information

Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette! The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in

More information

Product Bulletin. RCP Cooling System Treatment. Product Description. Primary Application

Product Bulletin. RCP Cooling System Treatment. Product Description. Primary Application Product Bulletin RCP Cooling System Treatment Product Description PrixMax RCP is a low toxic, environmentally friendly inhibitor concentrate for protection of engine cooling systems. Using proprietary

More information

10.6 Scope of Accreditation

10.6 Scope of Accreditation Testing Laboratory Accreditation is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing and calibration

More information

Industrial Chemical Standards Supplied by

Industrial Chemical Standards Supplied by Industrial Chemical Standards Supplied by jagschemes@live.com.au Standard Specification for Glycol Base Engine Coolant for Automobile and Light- Duty Service 1. Scope 1.1 This specification covers the

More information

TEST REPORT: CHM12-01-LSM

TEST REPORT: CHM12-01-LSM Date: Tel: +65 68851335 Fax: +65 67784301 Client s Ref: QM-0112-056 Email: Sihai.LI@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group

More information

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer Softening point by Ring & Ball Density and relative density of liquids by Hubbart pycnometer Distillation of petroleum Melting point of petroleum wax Precipitation number of lubricating oils Saponification

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION Document No.:JSS222.2016 Revision:A0 PRODUCT SPECIFICATION ALKALINE 9V BATTERY Type Designation: 6LR61UD/ 9V Prepared by : Checked by : Approved by : Issued Date : 2016-03-31 Zhongyin (Ningbo) Battery

More information

Pharmaceuticals USP Quality Control Edition.

Pharmaceuticals USP Quality Control Edition. Pharmaceuticals USP Quality Control Edition Pharmaceutical Test Solutions We supply a range of ready to use solutions prepared according to Pharmacopoeia guidelines. All of which are supplied with a Certificate

More information

The Measure of all Things. Volumetric Solutions from Merck

The Measure of all Things. Volumetric Solutions from Merck The Measure of all Things Volumetric Solutions from Merck Titration is the oldest but still the most precise procedure in chemical analysis. However, such precise analyses require accurately adjusted volumetric

More information

SUPPORTING INFORMATION

SUPPORTING INFORMATION SUPPORTING INFORMATION For Comparative Analysis of Halonitromethane and Trihalomethane Formation and Speciation in Drinking Water: The effects of Disinfectants,, Bromide, and Nitrite Jia Hu a, Hocheol

More information

Metallic Systems TYPE SPTC

Metallic Systems TYPE SPTC CONDUIT 27/01/2009 Technical Data Sheet Page No. 1 Applications Hospitals External Safety Critical Area Fittings IP54 SPB Fittings type A & B Characteristics Very High UV Resistance High Flexibility Medium

More information

PRICE LIST 2017/2018

PRICE LIST 2017/2018 PRECISION PETROLEUM LABS, INC. 5915 STAR LANE HOUSTON, TX 77057 PRICE LIST 2017/2018 PH: 713-680-9425 Fax: 713-680-9564* WEBSITE: PRECISIONLABS.ORG FUEL TESTING Acidity as Acetic Acid D-1613 $65.00 Alcohol

More information

In-Line Methods List for Automated Ion Analyzers. Flow Injection Analysis

In-Line Methods List for Automated Ion Analyzers. Flow Injection Analysis In-Line Methods List for Automated Ion Analyzers Flow Injection Analysis 19 January 2018 1 In-line Modules: Method Number Analyte Lamp/Tubing Heater/tubing 10-107-06-6-A Ammonia Not used 850cm Tefzel

More information

INSTRUCTIONS FOR ACID FILLING AND FIRST CHARGING OF DRY, UNCHARGED EXIDE India TRACTION BATTERIES

INSTRUCTIONS FOR ACID FILLING AND FIRST CHARGING OF DRY, UNCHARGED EXIDE India TRACTION BATTERIES INSTRUCTIONS FOR ACID FILLING AND FIRST CHARGING OF DRY, UNCHARGED EXIDE India TRACTION BATTERIES ACID FILLING INSTRUCTION: Fill the cells with battery grade sulphuric acid of 1.260 +/ 0.005 specific gravity

More information

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test Report On Evaluation Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Nonreference oil) and shall not be used for multiple test acceptance

More information

Etaprime B Type Series Booklet

Etaprime B Type Series Booklet Self-priming Pump Etaprime B Type Series Booklet Legal information/copyright Type Series Booklet Etaprime B All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

MiniLab EL Series for High Performance Engine Development and Maintenance

MiniLab EL Series for High Performance Engine Development and Maintenance MiniLab EL Series for High Performance Engine Development and Maintenance Optimize performance output Detect problems early Ensure safety in operation Engine Oil Analysis: A Reliable Technique for Engine

More information

Laboratory Method Evaluation Report GBRA, August 2013

Laboratory Method Evaluation Report GBRA, August 2013 Introduction Laboratory Method Evaluation Report GBRA, August 2013 The following report outlines information collected under Task 4.1 of Objective 4: Laboratory Method Evaluation of Agreement 582 12 20495,

More information

ANNEX 7 RESOLUTION MEPC.199(62) Adopted on 15 July GUIDELINES FOR RECEPTION FACILITIES UNDER MARPOL ANNEX VI

ANNEX 7 RESOLUTION MEPC.199(62) Adopted on 15 July GUIDELINES FOR RECEPTION FACILITIES UNDER MARPOL ANNEX VI Annex 7, page 1 ANNEX 7 RESOLUTION MEPC.199(62) Adopted on 15 July 2011 2011 GUIDELINES FOR RECEPTION FACILITIES UNDER MARPOL ANNEX VI THE MARINE ENVIRONMENT PROTECTION COMMITTEE, RECALLING Article 38(a)

More information

Standard Analysis Report

Standard Analysis Report Standard Analysis Report The status identifies the condition of the sample, Normal, Warning or Problem sample Laboratory sample number Clients details, equipment ID, Oil type and what compartment Date

More information

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis Metallo-Organic Standards from VHG Labs VHG Labs has been a provider of quality analytical products and services for over 25 years.

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

User Manual Electronic Titrator

User Manual Electronic Titrator User Manual Electronic Titrator BDI-TIT PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.3.17 Content 1. Unpacking...

More information

PROPOSED REVISION OF THE GENERAL CHAPTER 1.11 COLOUR OF LIQUIDS. for The International Pharmacopoeia

PROPOSED REVISION OF THE GENERAL CHAPTER 1.11 COLOUR OF LIQUIDS. for The International Pharmacopoeia July 2016 Draft for comment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 PROPOSED REVISION OF THE GENERAL CHAPTER 1.11 COLOUR OF LIQUIDS for The

More information

Self-priming Pump. Etaprime B. Type Series Booklet

Self-priming Pump. Etaprime B. Type Series Booklet Self-priming Pump Etaprime B Type Series Booklet Legal information/copyright Type Series Booklet Etaprime B All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Septage Land Application Module

Septage Land Application Module Septage Land Application Module Bruce Lesikar Texas Cooperative Extension Service University Curriculum Development for Decentralized Wastewater Management NDWRCDP Disclaimer This work was supported by

More information

Pretty catastrophic effects on both SX & EW operations.

Pretty catastrophic effects on both SX & EW operations. Managing Mn Effects in Cu SX ALTA 2010 Ni Ni Co Co Cu Conference METHODS OF MANAGING MANGANESE EFFECTS ON COPPPER SXSX-EW PLANTS GRAEME MILLER Miller Metallurgical Services INTRODUCTION Little literature

More information

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03) CONNECTION BULLETIN Vogt Valves Zero Leakage Forged Steel Check Valves Class 800 FCD VVABR1003-00 10/04 (Replaces CB-03) Experience In Motion Zero Leakage, Forged Steel Check Valves: Class 800 Vogt Series

More information

BIODEGRADABILITY TESTING OF ONE PRODUCT

BIODEGRADABILITY TESTING OF ONE PRODUCT BIODEGRADABILITY TESTING OF ONE PRODUCT Technical Report The Centre de recherche industrielle du Québec's mission is to contribute to the competitiveness of industrial sectors in Quebec by supporting

More information

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(09)-05 Issued July 2010

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(09)-05 Issued July 2010 U. S. Census Bureau Production and Stocks of Inorganic Chemicals - 2009 Summary MQ325A(09)-05 Issued July 2010 Address inquiries concerning these data to Primary Goods Industries Branch, U.S. Department

More information

Beyond Cold Gas Thrusters

Beyond Cold Gas Thrusters Beyond Cold Gas Thrusters Good - Simple Bad - Limited I sp How to increase specific impulse of monopropellant? raise T o Where will energy come from? chemical exothermic decomposition of monopropellant

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 13.02.2018 to 12.02.2023 Holder of certificate: DMT

More information

Conductivity Measurement CLM 280

Conductivity Measurement CLM 280 Technical Information TI 347C/07/en/07.03 51511754 Conductivity Measurement CLM 280 Battery-driven pocket meter for conductivity and resistance measurement Application CLM 280 is a compact pocket meter

More information

ITS Caleb Brett India:

ITS Caleb Brett India: ITS Caleb Brett India: World-Class Inspection & Quality Control Testing. Serving India, the region and the world. See Our Services Pages 2-17. ITS Caleb Brett India has six analytical testing laboratories

More information

150 Series Brass Horizontal Float Valve. Technical Information

150 Series Brass Horizontal Float Valve. Technical Information 150 Series Brass Horizontal Float Valve Technical Information HORIZONTAL FLOAT VALVES Based on a simple yet effective operating principle, Philmac horizontal float valves are quick and easy to install

More information

Technische Dokumentation Technical Documentation

Technische Dokumentation Technical Documentation Technische Dokumentation Technical Documentation XOMOX Resilient Seated Butterfly Valves Series 7500 XOMOX International GmbH & Co. OHG Dok. Nr.: tdb_7500_gb Von-Behring-Straße 15 D-88131 Lindau / Deutschland

More information

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger CMS The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip start measurement

More information

High pressure industrial ball valves

High pressure industrial ball valves High pressure industrial ball valves High pressure industrial ball valves Applications Legris high pressure ball valves are suited for a wide range of industrial applications. They are designed both for

More information

Bio Lion CENTRIFUGES.

Bio Lion CENTRIFUGES. Bio Lion CENTRIFUGES www.bio-lion.com Table of Contents Refrigerated High Speed Centrifuge Page 1-3 Refrigerated Low Speed Centrifuge Page 4 High Speed Centrifuges Page 5 - Page 8 Low Speed Centrifuges

More information

Variation Notice with introductory note

Variation Notice with introductory note Variation Notice with introductory note Pollution Prevention and Control Regulations 2000 Dudley Energy from Waste Facility MES Environmental Ltd Lister Road Dudley West Midlands DY2 8JT. Variation Notice

More information

Colorimetric Gas Detector Tube System US Dollar Price List

Colorimetric Gas Detector Tube System US Dollar Price List Colorimetric Gas Detector Tube System US Dollar Price List Sensidyne, LP - Gas Detector Tube Price List Effective Date: February 12, 2012 Rev. A 010612 Table of Contents Gas Detection Pump Kit & Accessories

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK Unit A Shears Way Brooklands Close Sunbury-on-Thames Middlesex TW16 7EE Contact: Mr Craig Stone Tel: +44 (0)1932 732103 Fax: +44 (0)1932 732113 E-Mail: craig.stone@intertek.com Website: SUMMARY OF ACCREDITATION

More information

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(10)-05 Issued July 2011

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(10)-05 Issued July 2011 U. S. Census Bureau Production and Stocks of Inorganic Chemicals - 2010 Summary MQ325A(10)-05 Issued July 2011 Address inquiries concerning these data to Primary Goods Industries Branch, U.S. Department

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SGS West Thurrock Laboratory Contact: David Mercer (Laboratory Manager) 859 London Road Tel: +44 (0)1708 681943 West Thurrock Fax: +44 (0)1708

More information

Electromagnetic Flowmeters

Electromagnetic Flowmeters Instruction Manual BOOK 6 Accessories and Spares IM/MM/BK6_6 Electromagnetic Flowmeters MagMaster TM AquaProbe TM AquaMag ABB The Company We are an established world force in the design and manufacture

More information

Electronic Monitoring Systems

Electronic Monitoring Systems JJ Electronic digital thermometer JJ Multi-channel temperature indicator JJ Temperature sensors JJ KombiTemp Electronic Monitoring Systems and Temperature Sensors DS_Electronic_monitoring_systems_and_temperature_sensors

More information

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene. Chemical Compatibility Chart 6 Stainless Acetic Acid Acetone Acetylene Acidic Mine Water Acrylonitrile Ammonium Chloride Ammonium Hydroxide Ammonium Sulfate Ammonium Thio-Sulfate Anhydrous Ammonia Anhydrous

More information

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Conveyors slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Application example conveyors Transport solutions and goods provision 1 2 3 4 5 6 7 8 362 9 1 slide strips Low-wear

More information

SEPA Statement Processed Fuel Oil

SEPA Statement Processed Fuel Oil SEPA Statement Processed Fuel Oil 1.0 Purpose This statement supports the production and use of Processed Fuel Oil (PFO) from waste lubricating oil and oil based mud cuttings. SEPA will not regulate as

More information

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill Kiwa Polymer Institut GmbH Quellenstraße 3 D-65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 8464-2-E Testing order: Tests on the coating Wecryl 124

More information

Sample Containers, Preservation Techniques, and Holding Times For Aqueous Matrices

Sample Containers, Preservation Techniques, and Holding Times For Aqueous Matrices Babcock Laboratories, Inc. Quality Manual Page App K-1 of App K-5 Sample Containers, Preservation Techniques, and Holding Times For Aqueous Matrices Bacteriological Analyses Coliform, Total SM9221B,SM9223

More information

Electronic Monitoring Systems

Electronic Monitoring Systems JJ Electronic digital thermometer JJ Multi-channel temperature indicator JJ Temperature sensors JJ KombiTemp Electronic Monitoring Systems and Temperature Sensors DS_Electronic_monitoring_systems_and_temperature_sensors

More information

Elemental Analysis Advanced

Elemental Analysis Advanced better analysis counts Elemental Analysis Advanced Rapid sulfur measurement plus 12 elements from P to Zn. ASTM D4294 ISO 8754 IP 336 Advanced Software and Data Management Petra offers the latest software

More information

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x Ac-225 Actinium(89) 0.6 16.2 1x10-2 0.270 2.1x10 3 5.8x10 4 Ac-227 40 1080 2x10-5 5.41x10-4 2.7 7.2x10 1 Ac-228 0.6 16.2 0.4 10.8 8.4x10 4 2.2x10 6 Ag-105 Silver(47) 2 54.1 2 54.1 1.1x10 3 3.0x10 4 Ag-108m

More information

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N ) CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November

More information

New Pig One Pork Avenue Tipton, PA Chemical Compatibility Guide for: FTI Pumps

New Pig One Pork Avenue Tipton, PA Chemical Compatibility Guide for: FTI Pumps Chemical Compatibility Guide for: FTI Pumps The guide on the following page(s) was provided by the supplier. New Pig Corporation assumes no responsibility, obligation, or liability in conjunction with

More information

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK FLUID CONVEYING PRODUCTS Section Pages Hose 15-67 Fittings 68-180 Adapters and Tube Fittings 181-228 Description Page Features 246, 247 Technical Data 248, 253 Gasket Selector Chart 249 How to Order 250

More information

HYPRA Prisinter 16/32/63 A

HYPRA Prisinter 16/32/63 A 8704 LIMOGES Cedex Telephone: + 33 0 06 87 87 - Fax: + 33 0 06 88 88 HYPR Prisinter 16/32/63 Page 1. General characteristics........1 2. Range......................1 3. Dimensions............... 2-3 4.

More information

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No. DATE SAMPLED 16-May-15 15-Apr-15 15-Mar-15 03-Mar-15 15-Feb-15 15-Jan-15 DATE RECEIVED 22-May-15 23-Apr-15 23-Mar-15 09-Mar-15 20-Feb-15 22-Jan-15 DATE REPORTED 26-May-15 24-Apr-15 24-Mar-15 11-Mar-15

More information

Successful Implementation of Cormetech Catalyst. in High Sulfur Coal-Fired SCR Demonstration Project

Successful Implementation of Cormetech Catalyst. in High Sulfur Coal-Fired SCR Demonstration Project Abstract Successful Implementation of Cormetech Catalyst in High Sulfur Coal-Fired SCR Demonstration Project Chris E. DiFrancesco Phone: 919-620-3015 Fax: 919-620-3001 CORMETECH, INC. 5000 International

More information

Tec Check. Fluid Analysis Program

Tec Check. Fluid Analysis Program Tec Check Fluid Analysis Program INTRODUCTION Cummins TEC Check Fluids Analysis Program is key for monitoring your engines contaminant levels, our program can provide evidence of system weakness or malfunction

More information

Why we need new Total Nitrogen parameter and methods for CWA reporting. William Lipps Chief Science Officer, Eurofins Eaton Analytical August 2018

Why we need new Total Nitrogen parameter and methods for CWA reporting. William Lipps Chief Science Officer, Eurofins Eaton Analytical August 2018 Why we need new Total Nitrogen parameter and methods for CWA reporting William Lipps Chief Science Officer, Eurofins Eaton Analytical August 2018 Full Service Laboratories Eurofins Lancaster Laboratories

More information

10.6 Schedule of Accreditation

10.6 Schedule of Accreditation GEO-CHEM Middle East Laboratory No. ATL0015 is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing

More information

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart How to Use the Chemical Compatibility Chart The following chart contains information regarding the expected effects of 7 day direct solvent exposure on materials used for production of vials, caps and

More information

10.6 Scope of Accreditation

10.6 Scope of Accreditation GEO-CHEM Middle East Laboratory No. ATL0015 is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A CONTENTS Page 5 555 09 5 555 29 5 555 59 5 555 9 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...2 4. Dimensions..............................3 5. Technical characteristics...5 6.

More information