UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

Size: px
Start display at page:

Download "UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No."

Transcription

1

2

3 DATE SAMPLED 16-May Apr Mar Mar Feb Jan-15 DATE RECEIVED 22-May Apr Mar Mar Feb Jan-15 DATE REPORTED 26-May Apr Mar Mar Feb Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN B Diesel Engine E141 LLA00495 Discoverer Generator 1 Engine Caterpillar 3512C LLA gal DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED gal FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) < Copper (Cu) Tin (Sn) <1 <1 <1 3 <1 1 Aluminium (Al) <1 < Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) Sodium (Na) Potassium (K) 5 6 <5 <1 7 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 1

4 UIN B U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 2

5 DATE SAMPLED 16-May Apr Apr Mar Feb Jan-15 DATE RECEIVED 22-May Apr Apr Mar Feb Jan-15 DATE REPORTED 26-May Apr Apr Mar Feb Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN Diesel Engine E142 LLAOO473 Discoverer Generator 2 Engine Caterpillar 3512C LLAOO473 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 3 < Copper (Cu) Tin (Sn) <1 <1 <1 <1 <1 1 Aluminium (Al) <1 1 <1 <1 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) <1 Sodium (Na) Potassium (K) 3 7 <1 <5 6 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 3

6 UIN U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 4

7 DATE SAMPLED 16-May Apr Mar Feb Feb Jan-15 DATE RECEIVED 22-May Apr Mar Feb Feb Jan-15 DATE REPORTED 26-May Apr Mar Feb Feb Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN Diesel Engine E140 LLAOO483 Discoverer Generator 3 Engine Caterpillar 3512C LLAOO gal DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED gal FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) Copper (Cu) Tin (Sn) <1 <1 <1 <1 <1 1 Aluminium (Al) 1 < Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) Sodium (Na) Potassium (K) 3 7 <5 10 <1 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 5

8 UIN U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 6

9 DATE SAMPLED 15-May Mar Feb Jan Dec Nov-14 DATE RECEIVED 22-May Mar Feb Jan Jan Nov-14 DATE REPORTED 26-May Mar Mar Jan Jan Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN 01035DD Diesel Engine E159 LLA02761 Pride Generator 1 Engine Caterpillar 3512C LLA02761 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) < Copper (Cu) Tin (Sn) <1 <1 2 <1 <1 <1 Aluminium (Al) 1 <1 < Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) Sodium (Na) 5 10 <1 5 <1 5 Potassium (K) 2 5 <1 <1 <5 6 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <1 6 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 7

10 UIN 01035DD U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 8

11 DATE SAMPLED 15-May Mar Feb Jan Dec Nov-14 DATE RECEIVED 22-May Mar Feb Jan Jan Nov-14 DATE REPORTED 26-May Mar Mar Jan Jan Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN 01035D6 Diesel Engine E160 LLAO1868 Pride Generator 2 Engine Caterpillar 3512C LLAO1868 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) < Copper (Cu) Tin (Sn) <1 <1 2 <1 <1 <1 Aluminium (Al) <1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) Sodium (Na) <1 5 Potassium (K) 4 <5 9 <1 <5 5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) 1 1 <1 2 1 <1 Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 9

12 UIN 01035D6 U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 10

13 DATE SAMPLED 15-May Mar Feb Jan Dec Nov-14 DATE RECEIVED 22-May Mar Feb Jan Jan Nov-14 DATE REPORTED 26-May Mar Mar Jan Jan Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN Diesel Engine E161 LLAO1875 Pride Generator 3 Engine Caterpillar 3512C LLAO1875 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO SIF NO TIME ON UNIT Hrs TIME ON OIL Hrs OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) < Copper (Cu) Tin (Sn) <1 <1 <1 <1 <1 <1 Aluminium (Al) <1 < Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) Sodium (Na) <1 6 Potassium (K) <5 7 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) Calcium (Ca) Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) Zinc (Zn) Molybdenum (Mo) Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) Fuel (%) 1 < Soot (%) Infrared Physical / Chemical Base Number (mgkoh/g) ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 11

14 UIN U.S. Laboratories Atlanta, Georgia Valley View, Ohio Presidential Drive Atlanta, GA Kansas City, Kansas Sunshine Road Kansas City, KS Portland, Oregon NW Front Avenue Portland, OR Canadian Laboratories Burlington, Ontario Burloak Drive, Unit 6 Burlington, ON L7L 6B Edmonton, Alberta Street Edmonton, AB T5S 1K Halle Dr. Suite D Valley View, OH Phoenix, Arizona West Earll Drive Phoenix, AZ Sparks, Nevada Greg Street, Suite 104 Sparks, NV Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold Katy Freeway Houston Tx USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas Stancliff Road, Suite 210 Houston, TX International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 12

15 SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Iron = Iron = Difference = % 13

16 SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Lead = 3.07 Copper = 5.55 Tin = 1.95 Lead = 5.0 Copper = 4.11 Tin = 1.47 Difference = +38.6% Difference = % Difference = % 14

17 SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Silicon = 2.5 Sodium = Silicon = 3.16 Sodium = 9.78 Difference = % Difference = % 15

18 SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Soot = 0.45 Fuel = 1.89 Soot = 0.32 Fuel = 1.0 Difference = % Difference = % 16

19 SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Viscosity = Viscosity = Difference = 0.0% 17

LUBRICANT (OIL) ANALYSIS COMPARISON

LUBRICANT (OIL) ANALYSIS COMPARISON LUBRICANT (OIL) ANALYSIS COMPARISON Objective (General): Objective (Specific): Methodology: Rig: Operated by: To monitor the rates of wear, contaminants and additives in used engine oils. Examples of contaminants

More information

Tec Check. Fluid Analysis Program

Tec Check. Fluid Analysis Program Tec Check Fluid Analysis Program INTRODUCTION Cummins TEC Check Fluids Analysis Program is key for monitoring your engines contaminant levels, our program can provide evidence of system weakness or malfunction

More information

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION COLD CORROSION MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION UNIMARINE MARINE ENGINES CYLINDERS SCRAPE-DOWN OIL ANALYSIS (CSDOA) FOCUS ON PREVENTIVE MAINTENANCE UniMarine provides high

More information

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis Metallo-Organic Standards from VHG Labs VHG Labs has been a provider of quality analytical products and services for over 25 years.

More information

FLUID ANALYSIS PROGRAM

FLUID ANALYSIS PROGRAM FLUID ANALYSIS PROGRAM What Can The Bobcat Fluid Analysis Program Do For You? Imagine being able to see exactly what s happening inside an engine, gearbox or hydraulic system. Bobcat Fluid Analysis is

More information

4 A village survey: Mandari, Lakshmipur

4 A village survey: Mandari, Lakshmipur 115 4 A village survey: Mandari, A rapid hydrochemical survey of the mouza (village) of Mandari, District was carried out during November 1999. Arsenic in the survey was measured in a various field laboratories

More information

Shell IMAA Workshop Making Sense of Oil Analysis

Shell IMAA Workshop Making Sense of Oil Analysis Shell IMAA Workshop Making Sense of Oil Analysis January 30, 2018 Tom Stuart Shell Lubricants Technical Advisor Greg Paluska Shell Lubricants Technical Team Lead East 04 October 2017 1 Why Oil Analysis?

More information

ENGINEERED LUBRICANTS CO.

ENGINEERED LUBRICANTS CO. ENGINEERED LUBRICANTS CO. LABORATORY FEE SCHEDULE Effective August 1, 2017 Page 1 of 5 Please send in SDS with samples. If you do not have an SDS please give a generic make-up of the product. (If we do

More information

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER Quality Oil Analysis Can Help Extend Equipment Life LubeWatch maintenance management system is a diagnostic, preventive

More information

MiniLab EL Series for High Performance Engine Development and Maintenance

MiniLab EL Series for High Performance Engine Development and Maintenance MiniLab EL Series for High Performance Engine Development and Maintenance Optimize performance output Detect problems early Ensure safety in operation Engine Oil Analysis: A Reliable Technique for Engine

More information

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck Antriebstechnik Drive Technology \\ Antriebsautomatisierung Drive Automation \ System \ Systemintegration Integration \ Services \ Services Condition Monitoring Service Oil Check Condition Monitoring Lubricant

More information

MiniLab EL Series for High Performance Engine Development and Maintenance

MiniLab EL Series for High Performance Engine Development and Maintenance MiniLab EL Series for High Performance Engine Development and Maintenance Optimize performance output Detect problems early Ensure safety in operation Engine Oil Analysis: A Reliable Technique for Engine

More information

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil Oil Analysis Oil Analysis: When the Oil Speaks, You Should Listen! Michael Holloway, ALS Tribology Ken Hill, WearCheck Lubrication Services Session Number T16 Elemental Detects the amount and type of elements

More information

Oil secure power and performance

Oil secure power and performance Oil analysis Oil secure power and performance through professional control Oil is the central component of every hydraulic system. When a system fails, oil contamination is usually the cause. Oil is continously

More information

Techenomics Oil Analysis Information

Techenomics Oil Analysis Information Techenomics Oil Analysis Information Oil Analysis is the sampling and Laboratory analysis of the lubricants properties; it provides knowledge of lubricants suspended s, and wear debris. Oil Analysis, generally

More information

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test Report On Evaluation Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Nonreference oil) and shall not be used for multiple test acceptance

More information

Rexro h. Service Visit Report. Bosch Group. For the attention of. Site Address: Aviemore, PH22 1RB. Customer Order Number: Visit Date:

Rexro h. Service Visit Report. Bosch Group. For the attention of. Site Address: Aviemore, PH22 1RB. Customer Order Number: Visit Date: Rexro h Bosch Group The Drive &Control Company Bosch Remo* tanned, Crernwt11 Road, St NEOTS PEN, 2Es Cairngorm Mountain Ltd Aviem ore Scotland PH22 1RB For the attention of Site Address: Customer Order

More information

Container MBW12K90MC Thursday 25 Jan 2007

Container MBW12K90MC Thursday 25 Jan 2007 Cylinder Oil Drain Analysis & Engine Performance Report Samples Landed : SINGAPORE - 26 Jan 7 Received at Analysis Labs : 29 Jan 7 Engine :SAMSUNG MAN B&W 12K9MC MCR : 74,64 bhp @ 94 rpm Next Samples Due

More information

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards NF&LCFT REPORT 441/13-010 Prepared By: MICHAEL PERETICH, PhD Oil Analysis

More information

Oil High-capacity and full of power reserve by premature check

Oil High-capacity and full of power reserve by premature check Oil analysis Oil High-capacity and full of power reserve by premature check Oil is the central component of every hydraulic system. When a system fails, oil contamination is usually the cause. Oil is continously

More information

OIL PT. Scheme Description. Oils and Fuels Analysis Proficiency Testing Scheme

OIL PT. Scheme Description. Oils and Fuels Analysis Proficiency Testing Scheme OIL PT Oils and Fuels Analysis Proficiency Testing Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury, BL9 0AP UK. Telephone: +44 (0) 161 762

More information

Standard Analysis Report

Standard Analysis Report Standard Analysis Report The status identifies the condition of the sample, Normal, Warning or Problem sample Laboratory sample number Clients details, equipment ID, Oil type and what compartment Date

More information

INTERPRETATION OF USED COOLANT ANALYSIS

INTERPRETATION OF USED COOLANT ANALYSIS RECO-COOL TECHNICAL BULLETIN 0006/12 INTERPRETATION OF USED COOLANT ANALYSIS Testing of coolants in use (whilst still within service) can give a vital indication on the health of the cooling system of

More information

What can the Hartland Fluid Analysis Program Do For You?

What can the Hartland Fluid Analysis Program Do For You? What can the Hartland Fluid Analysis Program Do For You? Hartland Fluid Analysis is a preventive maintenance tool that provides a picture of both the fluid condition and the internal condition of a component

More information

Fleet Solutions for Lubricant & Fluid Analysis

Fleet Solutions for Lubricant & Fluid Analysis Fleet Solutions for Lubricant & Fluid Analysis Maximize machine uptime Extend oil drains Prevent premature failures Oil Analysis for Vehicle Preventative Maintenance The reliable operation of vehicles

More information

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x Ac-225 Actinium(89) 0.6 16.2 1x10-2 0.270 2.1x10 3 5.8x10 4 Ac-227 40 1080 2x10-5 5.41x10-4 2.7 7.2x10 1 Ac-228 0.6 16.2 0.4 10.8 8.4x10 4 2.2x10 6 Ag-105 Silver(47) 2 54.1 2 54.1 1.1x10 3 3.0x10 4 Ag-108m

More information

SOME OTHER BENEFITS DERIVED FROM LUBE OIL ANALYSIS ARE:

SOME OTHER BENEFITS DERIVED FROM LUBE OIL ANALYSIS ARE: SAMPLING OVERVIEW: A preventive maintenance program using lube oil analysis is beneficial in many ways. With scheduled oil analysis, wear products can be identified and corrective action taken before equipment

More information

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards NF&LCFT REPORT 441/15-008 Prepared By: MICHAEL PERETICH, PHD

More information

PM 2.5 Impacts From Ship Emissions in the Pacific Northwest. Robert Kotchenruther Ph.D. EPA Region 10 NW-AIRQUEST Meeting, June

PM 2.5 Impacts From Ship Emissions in the Pacific Northwest. Robert Kotchenruther Ph.D. EPA Region 10 NW-AIRQUEST Meeting, June PM 2.5 Impacts From Ship Emissions in the Pacific Northwest Robert Kotchenruther Ph.D. EPA Region 10 NW-AIRQUEST Meeting, June 6-8 2012 Why look at ship emissions? Human Health & Ecosystem Concerns Health

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

lubricants analysis. complete solutions for your lab. Lubricants Analysis

lubricants analysis. complete solutions for your lab. Lubricants Analysis Lubricants Analysis lubricants analysis. complete solutions for your lab. PerkinElmer capabilities for lubricants analysis. The analysis of lubricants for conformity and process control has always been

More information

Establishing Proper Lubricant Service Intervals For Fleet Applications A Case Study by Dave Yunkers, Analysts, Inc.

Establishing Proper Lubricant Service Intervals For Fleet Applications A Case Study by Dave Yunkers, Analysts, Inc. Establishing Proper Lubricant Service Intervals For Fleet Applications A Case Study by Dave Yunkers, Analysts, Inc. Abstract Management has decided to pursue cost savings by extending oil drain intervals

More information

Penske Truck Leasing Oil, Fuel & Coolant Sampling Manual

Penske Truck Leasing Oil, Fuel & Coolant Sampling Manual Penske Truck Leasing Oil, Fuel & Coolant Sampling Manual Table of Contents Introduction...3 Oil Sample Scanning...3 Mailing Instructions...3 Steps Toward Taking A Good Oil Sample...4 Scheduled intervals...4

More information

Engine Oil Analysis. John C. Hildreth July 25, 2017

Engine Oil Analysis. John C. Hildreth July 25, 2017 Engine Oil Analysis John C. Hildreth John.Hildreth@uncc.edu July 25, 217 1. Purpose and Objective Purpose Understand how (fast) engine oil changes over time to investigate the potential for extending drain

More information

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer Advanced Petrochemical Applications With ICP-OES Tina Harville, Ph.D. Application Engineer Elemental Analysis of Petrochem-Based Solutions Refineries and Petrochemicals Sulfur content of gasoline Acceptance

More information

Water analysis, QC and more:

Water analysis, QC and more: Water analysis, QC and more: photoflex THE REAL MULTI COLORIMETER Standardized and easy-to-use Sturdy and waterproof Sophisticated and versatile Environmental Protection: Fish Farming and Surface Water:

More information

Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October December 2004

Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October December 2004 INL/EXT-05-00040 Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October December 2004 Larry Zirker James Francfort Jordan Fielding February 2005 The INL is a U.S. Department of Energy National

More information

Machine and Lubricant Condition Monitoring for Extended Equipment Lifetimes and Predictive Maintenance at Power Plants Abstract 1.

Machine and Lubricant Condition Monitoring for Extended Equipment Lifetimes and Predictive Maintenance at Power Plants Abstract 1. Machine and Lubricant Condition Monitoring for Extended Equipment Lifetimes and Predictive Maintenance at Power Plants by: Malte Lukas and Daniel P. Anderson Spectro Incorporated Littleton, Massachusetts,

More information

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6 Last Amended on - Page 1 of 6 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Quality Monitoring Respirable Suspended Particulate Matter Less than 10µm or PM10 IS:5182 (Part 23):2006 5-1000 µg/m3 Respirable

More information

The Role of Chemical Metrology in Transportation Industry

The Role of Chemical Metrology in Transportation Industry The Role of Chemical Metrology in Transportation Industry Dr Richard Shin Consultant Scientist Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group Health Sciences Authority,

More information

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES Application Note AN1705 Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications Chemist; Teledyne Leeman Labs Page

More information

Fundamentals of Oil Analysis

Fundamentals of Oil Analysis IRC RESEARCH AND TECHNOLOGY FORUM Wednesday May 6, 2015 Thursday May 7, 2015 Madison, WI 53706 University of Wisconsin-Madison Pyle Center 702 Langdon St. University of Wisconsin-Madison Fundamentals of

More information

Agenda. DEF Presentation Turn-Key DEF Solutions. Q & A Wrap-up and Depart

Agenda. DEF Presentation Turn-Key DEF Solutions. Q & A Wrap-up and Depart WELCOME CUSTOMERS Agenda Introduction DEF Presentation Turn-Key DEF Solutions Meeting Your DEF Needs Q & A Wrap-up and Depart Hollon Oil TET LSI Hollon Oil 2 Supply Quality and Security Emissions Standards

More information

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER Quality Oil Analysis Can Help Extend Equipment Life LubeWatch maintenance management system is a diagnostic, preventive

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK Unit A Shears Way Brooklands Close Sunbury-on-Thames Middlesex TW16 7EE Contact: Mr Craig Stone Tel: +44 (0)1932 732103 Fax: +44 (0)1932 732113 E-Mail: craig.stone@intertek.com Website: SUMMARY OF ACCREDITATION

More information

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9 Report No.: R-cn5-1505057-E-S2 Page 1 of 9 Applicant Name Applicant Address : WINHAND TOYS MANUFACTURING CO.,LTD : NO.106 HAIFA ROAD, HAICANG INDUSTRIAL DISTRICT, XIAMEN, CHINA. The following information

More information

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Analysis of Petroleum Samples Using the Teledyne Leeman Labs APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 ICP Petroleum Analysis of Petroleum Samples Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications

More information

Condition Based Maintenance System for Heavy Equipments Case study: Using Trend Analysis in Oil Monitoring

Condition Based Maintenance System for Heavy Equipments Case study: Using Trend Analysis in Oil Monitoring Proceedings of the 2011 International Conference on Industrial Engineering and Operations Management Kuala Lumpur, Malaysia, January 22 24, 2011 Condition Based Maintenance System for Heavy Equipments

More information

LabTec Fluid Analysis Program

LabTec Fluid Analysis Program Solutions... to keep it running Improve reliability & uptime. Reduce maintenance costs. Preserve capital asset value. SM LabTec Fluid Analysis Program Independent ISO 17025 A2LA Accredited Testing Services

More information

TRAFFIC VOLUME TRENDS

TRAFFIC VOLUME TRENDS Page 1 U. S. Department Transportation Federal Highway Administration Office Highway Policy Information TRAFFIC VOLUME TRENDS September Travel on all roads and streets changed by +2.5 (5.8 billion vehicle

More information

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE SCP SCIENCE 211 conostan - oil analysis standards SCP SCIENCE is proud to present CONOSTAN - the world s most trusted name in Oil Standards, whose industryleading position is the result of a uniquely superior

More information

TRACE ELEMENTS IN URINE. Event #3, 2012

TRACE ELEMENTS IN URINE. Event #3, 2012 TRACE ELEMENTS IN URINE Event #3, 202 November 30 th, 202 Event #3, 202 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent. Urine was collected

More information

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date Last Amended on - Page 1 of 5 I. WATER 1. Potable / Drinking Temperature IS 3025 (Part 9): 1984 (RA 2006) Ambient - 50 C Turbidity IS 3025 (Part 10): 1984 (RA 2006) 1 NTU to 100 NTU Specific Conductivity

More information

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date Ecosteps Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh Last Amended on - Page 1 of 10 Specific Performed Method Specification Range of ing / At I. WATER 1. Potable Water/ Domestic Bore Water/ De-mineralized

More information

JOINT OIL ANALYSIS PROGRAM MANUAL

JOINT OIL ANALYSIS PROGRAM MANUAL (NAVY) (ARMY) (AIR FORCE) (COAST GUARD) JOINT OIL ANALYSIS PROGRAM MANUAL VOLUME IV LABORATORY ANALYTICAL METHODOLOGY AND EQUIPMENT CRITERIA (NON-AERONAUTICAL) DISTRIBUTION STATEMENT A. Approved for public

More information

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date Fuel 2018 Month Number Type Dispatch Date Closing Date January February March April May June July August September October November December M902 Motor Gasoline, Premium A372 Aviation Gasoline, 100LL D295

More information

TRACE ELEMENTS IN URINE

TRACE ELEMENTS IN URINE TRACE ELEMENTS IN URINE Proficiency Test Report Event #1, 014 March 4 th, 014 Event #1, 014 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent.

More information

Sequence VH Report Forms Version Conducted For

Sequence VH Report Forms Version Conducted For Report Forms Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Non-Reference Oil) and shall not be used in determining an average test

More information

Anglomoil Hydraulic BIO-FR was designed to replace anti-wear, mineral oil based hydraulic fluids used in applications where fire hazards exist.

Anglomoil Hydraulic BIO-FR was designed to replace anti-wear, mineral oil based hydraulic fluids used in applications where fire hazards exist. Product Description Anglomoil Hydraulic BIO-FR was designed to replace anti-wear, mineral oil based hydraulic fluids used in applications where fire hazards exist. Product Features & Benefits PRODUCT DATA

More information

API Engine Oil Licensing and Certification System. API Lubricants Group November 2012

API Engine Oil Licensing and Certification System. API Lubricants Group November 2012 API Engine Oil Licensing and Certification System API Lubricants Group November 2012 1 Engine Oil Program Participation As of 11/5/2012 538 licenses in 56 countries 3 Africa 196 Asia 28 Central America

More information

Blade Fuses - Illuminated Mini Blade

Blade Fuses - Illuminated Mini Blade Photo Fuse Features: The photo fuse is designed for the automobile and electrical industry. It has become the original equipment circuit protection standard for automobiles, trucks and low power system.

More information

Diego Navarro. Condition Based Maintenance Consultant ME, OMA I

Diego Navarro. Condition Based Maintenance Consultant ME, OMA I Diego Navarro Condition Based Maintenance Consultant ME, OMA I diegonavarro47@gmail.com A Machine is Talking to us But, Are We paying Attention? The brakes are chattering There is a leak in boom cylinder

More information

STUDY OF RE-REFINED OIL USE IN DIESEL ENGINES: FINAL REPORT

STUDY OF RE-REFINED OIL USE IN DIESEL ENGINES: FINAL REPORT STUDY OF RE-REFINED OIL USE IN DIESEL ENGINES: FINAL REPORT Timothy T. Maxwell and Atila Ertas Multidisciplinary Research in Transportation Texas Tech University Lubbock, TX 79409 Submitted to: Texas Department

More information

ControllingSiliconandSootContentintheCrankCaseOiltoImprovePerformanceofDieselEngine

ControllingSiliconandSootContentintheCrankCaseOiltoImprovePerformanceofDieselEngine Global Journal of Researches in Engineering: A Mechanical and Mechanics Engineering Volume 16 Issue 2 Version 1. Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals

More information

10.6 Scope of Accreditation

10.6 Scope of Accreditation GEO-CHEM Middle East Laboratory No. ATL0015 is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing

More information

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9 Acidity SM 2310B 14 days - - 100 ml - - 250mL P None Alkalinity (as CaCO 3) SM 2320B 14 days NS 5 100 ml - - 250mL P None Ammonia Nitrogen SM 4500NH3-D 28 days - - 100 ml - - 250mL P H 2 SO 4 Asbestos

More information

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City Toshihiro Kuwayama, Chris R. Ruehl, and Michael J. Kleeman* Department of

More information

2013 Migration Patterns traffic flow by state/province

2013 Migration Patterns traffic flow by state/province Interstate and Cross-Border 2013 Migration Patterns traffic flow by state/province Based on 77,308 Interstate Household Goods Moves from January 1, 2013 through December 31, 2013 YUKON TERRITORY 0 0 BC

More information

/10 EN. Lubricating Oil for MWM Gas Engines. Technical Bulletin. The 10th replacement is made because of:

/10 EN. Lubricating Oil for MWM Gas Engines. Technical Bulletin. The 10th replacement is made because of: This Circular supersedes: 0199-99 - 02105/9 Lubricating Oil for MWM Gas Engines The 10th replacement is made because of: - Updating of the released lubricating oils This technical bulletin contains: -

More information

SEA-Mate Analyser and Blender

SEA-Mate Analyser and Blender Bunker Summit Greece 2007 SEA-Mate Analyser and Blender May 11 - Session 6: Under The Spotlight: New Technologies and innovation in the bunker sector 12:10 12:20 Terry Robinson Web: http://www.maerskfluid.com/

More information

Certificate of Accreditation

Certificate of Accreditation Certificate of Accreditation ISO/IEC 17025:2005 Certificate Number L2264.03 Analysts, Inc. 2450 Hassell Road Hoffman Estates IL 60195 has met the requirements set forth in L-A-B s policies and procedures,

More information

10.6 Schedule of Accreditation

10.6 Schedule of Accreditation GEO-CHEM Middle East Laboratory No. ATL0015 is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing

More information

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK Gohandmade Dsign International A/S HANNE Madevej 11-13 6200 Aabenraa DENMARK Date of order: 14.06.18 Contact: Penny Guo Direct dial: +86(21) 60725688 x 5659 Email: penny.guo@hansecontrol.com Test Report

More information

2016 Migration Patterns traffic flow by state/province

2016 Migration Patterns traffic flow by state/province Interstate and Cross-Border 2016 Migration Patterns traffic flow by state/province Based on 75,427 Interstate Household Goods Moves from January 1, 2016 through December 15, 2016 NL 8 13 YUKON TERRITORY

More information

Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study

Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study Authors Andrew Larson, The Dow Chemical Company Dr. Martin Greaves, The Dow Chemical Company The Dow Chemical

More information

Petrochemical standards

Petrochemical standards Conostan Oil Analysis Standards Petrochemical standards Reference standards for lubricant/oil analysis include: Element (metallo-organic) standards and associated blank oils and solvent (for ICP application),

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Non-Varnishing PAG-based Turbine Fluid and GEK Spec 32568h Recommendations. Govind Khemchandani, Ph. D. The Dow Chemical Company Freeport, TX, USA

Non-Varnishing PAG-based Turbine Fluid and GEK Spec 32568h Recommendations. Govind Khemchandani, Ph. D. The Dow Chemical Company Freeport, TX, USA Non-Varnishing PAG-based Turbine Fluid and GEK Spec 32568h Recommendations Govind Khemchandani, Ph. D. The Dow Chemical Company Freeport, TX, USA STLE May 18-22, 2014, Florida Dow.com Presentation Objectives

More information

APPENDIX D WATER QUALITY DATA

APPENDIX D WATER QUALITY DATA APPENDIX D WATER QUALITY DATA Mr. John Keating August 9, 2002 Page 2/8 SW-4 and at the settling pond near the bulk extraction area. In addition, total and faecal coliform bacteria samples are collected

More information

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For Report Packet Version No. Conducted For V = I = N = Valid; The reference oil/non-reference oil was evaluated in accordance with the test procedure. Invalid; The reference oil/non-reference oil was not

More information

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW - NEW Cerium Standards Sulfur-in-Oil Standards Viscosity Standards The benchmark for accurate measurements CALIBRATION AND VERIFICATION STANDARDS VERSION 4.0 HOW TO ORDER Telephone (Monday Friday, 8:30

More information

Sampling kits and test suites

Sampling kits and test suites Shell LubeAnalyst Sampling kits and test suites Oil sampling kits and test suites Basic K1 - Transport Monitors wear & contamination Basic Plus K1+ - Transport Determines optimum drain intervals Differentials,

More information

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214)

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214) December 15, 2011 Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) 221-9494 4821 Eastover Circle Fax: (214) 341-3182 Mesquite, TX 75149 Email: gabrielojeda@fritzpak.com Subject: Final Report (Revised)

More information

CERTIFICATE VO SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

CERTIFICATE VO SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager Page: 1 CERTIFICATE VO14023942 P.O. No.: KL 000348 This report is for 2 Drill Core samples submitted to our lab in Val d'or, QC, Canada on 18-FEB-2014. The following have access to data associated with

More information

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107

More information

Supply of Services for Detailed OEB Crude Assay Analysis

Supply of Services for Detailed OEB Crude Assay Analysis Tender Number [9900009229] Supply of Services for Detailed OEB Crude Assay Analysis SCOPE OF WORK SCOPE OF WORK 1. Introduction Orpic is the brand name for Oman Oil Refineries and Petroleum Industries

More information

CALIBRATION AND VERIFICATION STANDARDS

CALIBRATION AND VERIFICATION STANDARDS - - Head Office 21800 Clark Graham Avenue Baie D Urfé, QC H9X 4B6, Canada www.conostan.com sales@scpscience.com Tel: (800) 361-6820 (Toll free in the U.S. and Canada) +1 (514) 457-0701 USA 348 Route 11

More information

Application for Energy and Fuels

Application for Energy and Fuels Application for Energy and Fuels Improved Throughput for Wear Metals Analysis by ICP-OES Using Next Generation Sample Introduction Technology Patrick Simmons, Doug Shrader & Phil Lowenstern Agilent Technologies

More information

Cat S O S Services. Understanding Your Results. Understanding Your: S O S Reports S O S Oil Results S O S Coolant Results S O S Fuel Results

Cat S O S Services. Understanding Your Results. Understanding Your: S O S Reports S O S Oil Results S O S Coolant Results S O S Fuel Results Cat S O S Services SM Understanding Your Results Understanding Your: S O S Reports S O S Oil Results S O S Coolant Results S O S Fuel Results Contents Overview of S O S Reports... 4 Overview of S O S Interpretation...

More information

QC CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

QC CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager Page: 1 QC CERTIFICATE SD16032427 This report is for 1 Rock sample submitted to our lab in Sudbury, ON, Canada on 4-MAR-2016. The following have access to data associated with this certificate: TOM VANDRUNEN

More information

1 Alloy specification of standard sacrificial anodes BOLT-ON ANODES / DISC ANODES

1 Alloy specification of standard sacrificial anodes BOLT-ON ANODES / DISC ANODES Page: CONTENTS: 1 Alloy specification of standard sacrificial anodes 2 Use of zinc or aluminium anodes 3 Use of sacrificial anodes in tanks HULL ANODES 4 23 Aluminium hull anodes 24 40 Zinc hull anodes

More information

National Routing Number Administration p-ani Activity and Projected Exhaust Report

National Routing Number Administration p-ani Activity and Projected Exhaust Report National Routing Number Administration 2016 p-ani Activity and Projected Exhaust Report The ATIS Industry Numbering Committee developed the P-ANI Administration Guidelines, which contain the following

More information

Wear Element Monitoring by Spectrometric Analysis in Automatic Transmission Bus

Wear Element Monitoring by Spectrometric Analysis in Automatic Transmission Bus 50, Issue 2 (2018) 89-96 Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Journal homepage: www.akademiabaru.com/arfmts.html ISSN: 2289-7879 Wear Element Monitoring by Spectrometric

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE

More information

Introduction Engine Test Solutions Industrial Plant Solutions Fleet Maintenance Solutions

Introduction Engine Test Solutions Industrial Plant Solutions Fleet Maintenance Solutions Fluid Analysis Solutions 2018 Table of Contents Introduction... 4-6 Engine Test Solutions... 7-14 Industrial Plant Solutions... 15-30 Fleet Maintenance Solutions... 31-42 Portable Oil Analysis Tools...

More information

Calibration & Verification Standards

Calibration & Verification Standards - - Online: www.conostan.com Email: sales@scpscience.com Order Online at: www.scpscience.com NORTH AMERICA USA: 348 Route 11 Champlain, NY 12919-4816 CANADA: 21800 Clark Graham Avenue Baie D Urfé, QC H9X

More information

TRAFFIC VOLUME TRENDS July 2002

TRAFFIC VOLUME TRENDS July 2002 TRAFFIC VOLUME TRENDS July 2002 Travel on all roads and streets changed by +2.3 percent for July 2002 as compared to July 2001. Estimated Vehicle-Miles of Travel by Region - July 2002 - (in Billions) West

More information

MnI Diesel, LLC MnI Maintenance, LLC. Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

MnI Diesel, LLC MnI Maintenance, LLC. Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green! MnI Diesel, LLC MnI Maintenance, LLC Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green! Oil Characteristics Oil does not wear out It oxidizes during the combustion process It becomes

More information

Test Method D5967 Mack T-8. Version. Method: Conducted For

Test Method D5967 Mack T-8. Version. Method: Conducted For Method D5967 Mack T-8 Version Method: Conducted For T-8A: T-8: T-8E: V = Valid I = Invalid N = Not Interpretable The Reference Oil/Non-Reference Oil was evaluated in accordance with the test procedure.

More information

All Applicants - By HS GPA Run Date: Thursday, September 06, Applicants GPA Count % of Total

All Applicants - By HS GPA Run Date: Thursday, September 06, Applicants GPA Count % of Total All Freshmen: 3 Year Comparison of Fall Applications Received, Degree, Net s and Net s GPA All - By HS GPA Net s 3.900-4.000 1932 44.3 1840 55.8 441 57.0 24.0 35 1395 3.800-3.899 301 6.9 267 8.1 54 7.0

More information