1 JM Aerofoil Bifurcated Fans

2 JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection 7 Bifurcated Fan - Series 33 Motor Frame Size Schedules:- C Continuous 9 2 C Contnuous 1 Page: Performance Curves SK Dimensions & Weights - Series Dimensions & Weights - JM 26 Ancillaries

3 JM AEROFOIL - BIFURCATED INTRODUCTION Woods Air Movement Limited has made Axial flow fans for specialist applications and arduous environments for over years. As an acknowledged leader within the industry we have developed a series of bifurcated cased axials, utilising the improved performance JM Aerofoil range and taking into account the two most important factors to be considered - safety and economy. All fans are of the highest quality, built to the latest British and International standards, and incorporating motors rated in accordance with BS5 Part 99 and IEC This catalogue details the range of pre-designed products available with a Bifurcated casing. Other product variants are available on an individual order basis, please enquire of your local sales office if extra information is required. (For details visit The JM AEROFOIL Bifurcated Range JM This catalogue contains the complete range of JM Aerofoil Bifurcated fans, either for + C or +2 C continuous operation, from 4 mm to mm diameter. The impeller pitch angles are factory set to individual performance requirements. JM Series 33 This is our range of small bifurcated fans and consists of 15mm, 25mm and 3mm diameters for temperatures of 2 C. For our range of continuous operation high temperature smoke clearance bifurcated fans please see Fans in Fire Safety catalogue ref: C1 or contact your nearest sales office. FANS AVAILABLE FROM WOODS AIR MOVEMENT Axial Flow Fans - for standard and smoke clearance applications Roof Units - for standard and smoke clearance applications Varofoil - variable pitch in motion fans Centrifugal Fans - industrial & commercial In Line Centrifugal Mixed Flow Fans Plate Mounted Fans OTHER BIFURCATED RANGES Large Bifurcated Range For higher duties there is our large J bifurcated fan 4" (125mm) diameter. For full details please enquire at your nearest sales office. Partnership Collection & Standard Range The Partnership Collection and Standard Range are specific products available on fast lead times to satisfy your requirements. Details can be found in publication number PC/CORP. Series 33 Bifurcated fan 3

4 JM AEROFOIL - BIFURCATED APPLICATION THE JM BIFURCATED FAN The JM Aerofoil Bifurcated fan has been developed to handle; wet or dirty atmospheres, hot gases, emergency smoke clearance, dust laden air. The motor is isolated from the main air stream by a tunnel which extends to the side of the main fan casing only. The motor is cooled by air directly over its carcass by means of a cooling fan mounted on a shaft extension at the tail end. An air splitter in the tunnel separates the incoming cool air from the outgoing warm air. On sizes 4 mm to 1 mm the mouth of the tunnel is spigotted so that an extension duct giving access to normal atmosphere can be fitted in cases where the fan is mounted inside equipment, such as a drier, where air is required from another area lower than ambient for motor cooling. MOTOR COOLING AIR OUTLET TERMINAL BOX MOTOR COOLING INLET MOTOR PROTECTION TUNNEL AIRFLOW FORM B ONLY JM IMPELLER 4/5 fl BIFURCATED DUCT COOLING FAN TYPICAL APPLICATIONS Temperature Range Different sizes of fan are rated for different maximum temperature as in the table below:- Maximum Temperature C 2 C C* 15-3 mm X X 4-1 mm X X *Special - made to order only Mists and Condensation The Bifurcated fan is capable of handling mists up to 1 % relative humidity. When there is a danger of vapour condensing out in the fan duct 15 mm to 5mm diameter fans should not be mounted horizontally due to their case design. All ducts should be laid to a slight fall to facilitate drainage. Dusts Where there is a danger of dusts building up around the motor of a standard axial fan the Bifurcated fan eliminates this problem with its motor out of the airstream. Care must be taken to maintain minimum velocities for the conveying of dusts in the air stream. (If the dust causes a change from standard air density (1.2 kg/m 3 ) please refer to your nearest sales office). Flammable Gases With the additional fitting of a spark minimising impeller track, the fans are suitable for Group 2A and 2B gases. The fan must be mounted outside of the hazardous area. The shaft seal must be correctly maintained. Corrosive Chemicals The Bifurcated fan is suitable for some mild chemicals that will not corrode the galvanised casing or the seal of the motor shaft through the case. Additional protection can be provided by an epoxy paint finish. Please refer corrosive chemicals such as acids and solvents to ourselves where we can advise on the suitability of the fan. 4

5 JM AEROFOIL - BIFURCATED SPECIFICATION Motors Constructed from aluminium as standard with special stud and pad mounting fixings. Suitable for horizontal through to vertical shaft operation. Supplied IP55 Insulation is Class F, with Class F temperature rise. Bearing lubricated with wide temperature range grease, relubricatable or sealed for life bearings dependant on size. The motor is cooled by ambient air drawn into the tunnel which extends to the side of the casing, and is suitable for continuous operation for up to 4 C ambient. Speed Control Woods do not offer speed control for the bifurcated fan by conventional electronic or autotransformer speed control. This is due to the motor construction. For inverter drive applications enquire at Colchester. Starting Standard three phase motors of 5.5 kw outputs and above are usually provided with Star/Delta starting connections. Electrical Supply 23 V +1/-6 %; 5Hz; single phase (1φ )* 4 V +1/-6 %; 5Hz; three phase (3φ ) (6Hz and other voltages are available on request). Casings The JM Aerofoil Bifurcated design is generally similar to a normal axial flow fan, but the motor is isolated from the main air stream by a tunnel which extends to the side of the fan casing. The casing of the 15mm to 5mm diameter sizes have an enlarged bore located around the motor to permit adequate cross sectional area for air to flow round the motor tunnel. The 63 mm to 1 mm diameter sizes have casings of constant diameter. Impellers Small Bifurcated 15 mm - 3 mm Cast aluminium silicon one piece with fixed aerofoil section blade. Large Bifurcated 4 mm - 1 mm High pressure die and clamp plate, with equally spaced, fully adjustable, high pressure die cast section blades. All rotating aluminium components are X-ray examined prior to machining to ensure quality. Balanced to BS661 Part (ISO ) Grade G6.3. Ancillaries Guards to comply with BS4 Pt 5. and draft ISO standards. 2 speed switch for Delta/Star reconnection Silencers Mounting feet for both horizontal and vertical mounting Matching Flanges. Flexible Connectors. Air Operated Dampers.** Bellmouth inlets. ** Vibration Isolators. Finish Standard: The fan casing, mounting feet, matching flanges and guards are all hot dipped galvanised after manufacture, (in accordance with BS729:1971). Motors, aluminium self finish, or painted to motor manufacturers specification. Non Standard: For more corrosive conditions the fans can be treated at extra cost with an epoxy paint finish. The maximum temperature for this finish is +12 C (continuous). Additional Extra Features Epoxy Paint System Finish. Non Standard Voltages. Motor Thermistors. Motor Thermostats or Thermal Switches. Motor anti-condensation Heaters. Spark Minimising Feature. * Available 15 mm - 3 mm only ** Available 4 mm - 1 mm only 5

6 JM AEROFOIL - BIFURCATED FORMS OF RUNNING, TEST METHODS & QUALITY SYSTEMS The direction of airflow through the fan and the mounting position are defined as the Form of Running. Woods only offer Form B running bifurcated fans as Form A fans have a marked loss in performance. For vertical operation add suffix U for airflow up, or suffix D for airflow down. Arrows indicating correct rotation and the direction of air flow are incorporated on the fan duct nameplate. Single Stage Form B Form BU Form BD Two Stage For Two Stage selections, please refer your enquiry to a Woods representative. Form B/B Testing The air and sound performance data has been measured by the latest version of British and International Standards:- ISO 51 category D (fully ducted) method for testing air performance (supercedes BS4 Pt1 19). BS4 Pt 2 195, method of noise testing. It is essential, when comparing fan performances, that the same installation category and test standards are used at all times. Acoustic Data The sound levels quoted are based on tests carried out under the Woods certified laboratory conditions. Using the spectrum corrections stated on each performance chart, an unweighted sound power spectrum can be obtained for the fan. Motor Ratings The motor ratings, starting, full load currents and speeds refer to the maximum output of the motor. When the impeller does not require the full output, the power and current will be less than the maximum quoted. Anechoic Test Suite at Colchester Quality Systems Woods Air Movement are committed to Quality Assurance. Registered to BS EN ISO 91.94, N.A.T.O. Quality Standard AQAP-1 Edn 3. BS EN ISO registration means that Woods design is quality assured as well as the manufacture. Our commitment to Quality Assurance doesn't stop with the hardware. The performance data comes from standard tests carried out in Woods own laboratory which is BSI (CAME) and AMCA accredited. A JM Aerofoil Bifurcated fan can be bought with the confidence, as with all Woods products, that it will achieve the published performance data and match the assured quality. All the Woods JM Aerofoils are fitted with IP55 motors as standard, and come with a 2 year guarantee. 6

7 JM AEROFOIL - BIFURCATED GUIDE TO FAN SELECTION Within this publication there is all the information that you will require to make a full technical selection with fan, motor, electrical and acoustical details. The method of selection is the same as the standard JM Aerofoil fan, as detailed in our publication JM/SS pages 1 to 13. If you should require any further information or options that are not within this catalogue please contact your nearest sales office. PERFORMANCE JM Aerofoil Bifurcated Fans - 4JM - 1JM 1 6 4JM/2/2/6 5JM/2/2/6 1JM//4/6 4 63JM/2/4/6 JM/2/4/6 Total Pressure Pa JM/2/4/6 5JM/2/4/6 5JM//4/5 4JM//4/5 63JM/2/6/6 JM/2/6/6 1JM/25/6/ Volume Flow Rate m 3 /s 7

8 JM AEROFOIL - BIFURCATED SERIES 33 Fan Sizes 15 mm to 315 mm The Woods Series 33 Bifurcated fan of steelplate construction exhausts or recirculates fumes, gases or air at temperatures up to C. Two types are available for up to 2 C and up to C. The fans are designed for continuous running while subject to that temperature. Standard sizes are 15 mm, 25 mm and 35 mm providing volumes up to.9 m 3 /s with pressures up to 49 Pa. The fan is direct drive by motor housed within its own compartment, isolating it from the airstream. Ease of access to the motor for maintenance purposes also makes the fan eminently suitable for the conventional axial fan's normal application. Motors All motors are totally enclosed fan cooled, Class F insulation with motor protection to IP54. All motors are supplied with sealed for life bearings. They are not suitable for speed regulation by voltage. Inverter control - please enquire. Electrical Data Product Code Speed (rev/min) Motor Motor Rating (kw) V / 5 Hz / 1φ Full Load Current (at 23 V) (A) Starting Current (at 23 V) (A) Electrical Supply 22 V -24 V 5Hz 1φ 3 V - 42 V 5Hz 3φ Casings All casings are hot dipped galvanised for long life and high resistance corrosion. A seal is provided on the motor shaft. Impellers Cast in aluminium silicon alloy and has a fixed pitch aerofoil blade. This ensures strength, reliability and performance at high temperature. Temperature Range Standard 2 C, made to order C. Ancillary Equipment Silencers, Mounting Feet/Plates, Vibration Isolators, Matching Flanges, High Temperature Flexible Connectors. Motor Rating 15JM D JM D JM D JM D JM D (kw) 3-42 V / 5 Hz / 3φ Full Load Current (at 4 V) (A) Sound pressure levels quoted are average db(a) at 3 m distance over a sphere, based on form B running under free field conditions, and are presented for comparative purposes only. Cylindrical silencers are available as standard. Bifurcated fans are not suitable for speed regulation. Starting Current (at 4 V) (A) Sound Level db(a) p sf - Fan (Static) Pressure (Pa) ft 3 /min m 3 /hr JM rev/min 3JM rev/min 25JM rev/min 1 3JM rev/min 25JM rev/min mm wg in wg q v - Volume Flow (m 3 /s)

9 JM AEROFOIL - BIFURCATED Motor Frame Size Schedules: C Continuous 4 V / 5 Hz / 3 φ Code Speed rev/min Max. Angle ( ) Motor Motor Rating (kw) Full Load Current (A) Starting Current d.o.l. (A) Efficiency % Power Factor cos Ø 4JM.BIF//4/5/ DA71MAC DA71MAC JM.BIF/2/4/6/ DA71MAC DA71MAC JM.BIF/2/2/6/ F F F F F JM.BIF//4/5/ DA71MAC DA71MAC DAMAC DAMAC JM.BIF/2/4/6/ DA71MAC DA71MAC DAMAC DAMAC JM.BIF/2/2/6/ F F F F F F JM.BIF/2/6/6/ F F JM.BIF/2/4/6/ DAMAC F F F JM.BIF/2/6/6/ F F F JM.BIF/2/4/6/ F F F F JM.BIF/25/6/9/ DA132SAD DA132MAD DA132MBD JM.BIF/25/4/9/ DA132SAD DA132MAD DAMAD DALAD Standard Range products shown in italics 9

10 JM AEROFOIL - BIFURCATED Motor Frame Size Schedules: 2 C Continuous 4 V / 5 Hz / 3 φ Code Speed rev/min Max. Angle ( ) Motor Motor Rating (kw) Full Load Current (A) Starting Current d.o.l. (A) Efficiency % Power Factor cos Ø 4JM.BIF/2/4/6/ F JM.BIF/2/2/6/ F F F JM.BIF/2/4/6/ F F2245C JM.BIF/2/2/6/ F F F F JM.BIF/2/6/6/ F F JM.BIF/2/4/6/ F2245C F F F JM.BIF/2/6/6/ F F JM.BIF/2/4/6/ F F JM.BIF/25/6/9/ DA132SAD DA132MAD DA132MBD JM.BIF/25/4/9/ DA132SAD DA132MAD DAMAD DALAD Standard Range products shown in italics 1

11 JMAEROFOILÐBIFURCA TED Fan Code: 4JM.BIF//4/5/... BS575 Pt 1 4 mm 144 rev/min 5 Blades 5 Hz EN291 ISO 91 Performance Data ISO 51: Performance shown ispecifically fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures onperformance curves are overall inlet sound power levels, derived from measurements taken inwoods laboratory specifically under ducted conditions. For sound power levels ineight octave bands, apply the following corrections tothe overall level.use upper corrections when operating point isabove shaded area, or lower corrections when operating point isbelow shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð1 1 Ð1 1 Ð29 Ð1 1 Ð29 Ð2 Ð1 1 Ð1 1 Ð2 Ð Ð2 Ð1 1 SK1751 6/12/96

12 JMAEROFOILÐBIFURCA TED Fan Code: 4JM.BIF/2/4/6/... BS575 Pt 1 4 mm 144 rev/min 6 Blades 5 Hz EN291 ISO 91 Performance Data ISO 51: Performance shown ispecifically fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures onperformance curves are overall inlet sound power levels, derived from measurements taken inwoods laboratory specifically under ducted conditions. For sound power levels ineight octave bands, apply the following corrections tothe overall level.use upper corrections when operating point isabove shaded area, or lower corrections when operating point isbelow shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 1 4 Ð2 Ð2 Ð Ð1 1 Ð1 1 SK1752 6/12/96

13 JM AEROFOILÐBIFURCATED Fan Code: 4JM.BIF//2/5/... 4 mm 291 rev/min 5 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 6 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k 24 Ð 4 24 Ð 4 SK1753 6/12/96

14 JM AEROFOILÐBIFURCATED Fan Code: 4JM.BIF/2/2/6/... 4 mm 295 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 7 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 Ð2 24 Ð 4 Ð2 24 Ð 4 SK1754 6/12/96

15 JM AEROFOILÐBIFURCATED Fan Code: 5JM.BIF//4/5/... 5 mm 144 rev/min 5 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð29 Ð29 Ð2 Ð2 24 Ð 4 Ð2 24 Ð 4 SK1755 6/12/96

16 JM AEROFOILÐBIFURCATED Fan Code: 5JM.BIF/2/4/6/... 5 mm 144 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 3 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 1 4 Ð2 Ð2 24 Ð Ð 32 SK1756 6/12/96

17 JM AEROFOILÐBIFURCATED Fan Code: 5JM.BIF//2/5/... 5 mm 295 rev/min 5 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k 24 Ð 4 24 Ð 4 SK1757 6/12/96

18 JM AEROFOILÐBIFURCATED Fan Code: 5JM.BIF/2/2/6/... 5 mm 295 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 Ð2 24 Ð 32 Ð2 24 Ð 32 SK175 6/12/96

19 JM AEROFOILÐBIFURCATED Fan Code: 63JM.BIF/2/6/6/ mm 935 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 5 Ð29 Ð2 4 Ð2 Ð2 Ð Ð 32 Ð2 24 Ð 32 Ð2 SK1759 6/12/96

20 JM AEROFOILÐBIFURCATED Fan Code: 63JM.BIF/2/4/6/ mm 144 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k 1 Ð29 24 Ð Ð 32 SK176 6/12/96

21 JM AEROFOILÐBIFURCATED Fan Code: JM.BIF/2/6/6/... mm 935 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 3 Ð29 1 Ð2 24 Ð Ð 24 Ð2 SK1761 6/12/96

22 JM AEROFOILÐBIFURCATED Fan Code: JM.BIF/2/4/6/... mm 144 rev/min 6 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 Ð29 Ð2 Ð2 24 Ð 24 Ð2 24 Ð 24 SK1762 6/12/96

23 JM AEROFOILÐBIFURCATED Fan Code: 1JM.BIF/25/6/9/... 1 mm 96 rev/min 9 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 3 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 Ð2 Ð1 Ð2 Ð29 Ð2 Ð2 Ð2 24 Ð 3 Ð2 24 Ð 3 Ð2 SK /3/9

24 JM AEROFOILÐBIFURCATED Fan Code: 1JM.BIF/25/4/9/... 1 mm 147 rev/min 9 Blades 5 Hz BS 575 Pt 1 EN 291 ISO 91 Performance Data ISO 51: Performance shown is specifically for fully ducted installations ISO 51 7 V Type D Sound Data BS4 Part 2 195: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Angle k 2k 4k k Outlet Levels Angle k 2k 4k k Ð2 Ð2 Ð2 Ð2 Ð2 Ð2 24 Ð 3 24 Ð 3 Ð2 SK /3/9

25 JM AEROFOIL - BIFURCATED DIMENSIONS AND WEIGHTS 15JM.33-3JM.33 S No. of holes T on H P.C.D. 3 C AIRFLOW A B D FORM B ONLY L crs. M Attachable feet, thickness 3 mm Entry For J Conduit K C Code Motor A B C D E H J K L M P S T Weight (kg) 15JM.33 D CM JM.33 D CM D CM JM.33 D CM D CM

26 JM AEROFOIL - BIFURCATED DIMENSIONS AND WEIGHTS 4JM.Bif - 5JM.Bif 235 F Hole J S No. of holes T on H P.C.D. E P G D AIRFLOW FORM B ONLY B A L crs. M Slots in feet N Attachable feet, thickness 3 mm K C D71 & D motors have no external terminal box. Code Motor A B C D E F G H J K L M N P Q S T Weight (kg) 4JM.Bif D F D JM.Bif F F JM.Bif - 1JM.Bif S No. of holes T on H P.C.D. E F Hole J P G D A B AIRFLOW FORM B ONLY Attachable feet thickness Q (optional extra) L crs. M Slots in feet N K crs. C Code Motor A B C D E F G H J K L M N P Q S T U Weight (kg) 63JM.Bif F JM.Bif F D JM.Bif D D All dimensions shown in mm 12

27 JM AEROFOIL - BIFURCATED ANCILLARIES GUARDS TYPE I Impeller Side C TYPE IV Bellmouth & Motor Side C Suitable for fan Type C Weight ØA (kg) 4 I IV I IV I IV I IV I IV 5 2. BELLMOUTH C Suitable for fan C D Weight ØA Max. (kg) D A Holes to match fan flange Suitable for fan D E F G Weight (kg) Matching Flexible Damper ØA Flange Connection MATCHING FLANGE D FLEXIBLE CONNECTION E DAMPER G F

28 JM AEROFOIL - BIFURCATED ANCILLARIES SILENCER - B (& C) TYPE C Suitable for fan ØA ØB C Length 1Ø 2Ø PCD Thread M6 Weight (kg) B Type C Type 1Ø 2Ø 1Ø 2Ø M PCD B A POD - TYPE C ONLY M M M Tapped Holes to match fan M M The above silencers give the approximate db(a) reductions:- B Type 1 diameter length - 7 to 1 db(a) C Type 1 diameter length - 12 to 15 db(a) For full acoustic details contact our Woods Acoustic Divsion Telephone: +44() VIBRATION ISOLATORS 2 holes ØG RUBBER IN SHEAR B Load Type range per mounting A B C D E F G H (kg) M27 Green M6 M7 Black M6 M25 Green M M25 Black M M2 Green M1 F A ØD Mounting screw H supplied M2 Black M1 C E OPEN SPRING Type Rated Load (kg) Deflection at rated load (mm) Free Height (mm) Base fixing centres (mm) Base fixing hole ø Mounting Screw 3 Yellow M M1 6 Green M M1 14

29 Precise Air Management Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is the only company in the UK capable of providing total system solutions from the following portfolio: Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1kW. Designed to minimise annual energy consumption in all types of buildings. Chilled beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or flush-mounted ceiling installation and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Smoke control and car park ventilation systems Unique approach to car park ventilation, aided and optimised by Computational Fluid Dynamics (CFD) software. Complete turnkey solutions for designing, installing and commissioning mechanical and natural smoke ventilation. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Technical Site Services Our dedicated team providing comprehensive post-installation services. Including condition-based contract monitoring, preventative and routine maintenance, refurbishment and system upgrades. Fläkt Woods operates a policy of continuous development and improvement. Accordingly, the Company reserves the right to supply products that may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order. FWGJRG/JFB-3/1 Actom Mechanical Equipment Corner of Branch & Alpha Roads Driehoek, Germiston Tel (11) 779 Fax(11)7677 nuno.pereira@actom.co.za

JM Aerofoil Bifurcated 50Hz

JM Aerofoil Bifurcated 50Hz JM Aerofoil Bifurcated 5Hz JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection

More information

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment Roof Extract Units Roof Units Specification The Flaktwoods Colchester range of roof extract units are designed to satisfy the consultants functional requirement for a direct drive fan unit of guaranteed

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

CASED 24 Designed for emergency ventilation of hot fire smoke applications 300 C or 400 C for two hours operation, CE marked to EN12101-3 2002 All casings are hot dipped galvanised Sizes from 315mm to

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

Section 4 e c tio - P lat F a n s

Section 4 e c tio - P lat F a n s Plate Fans Section 4 The Fläkt Woods Plate Fan Range is the result of detailed market analysis and intensive research and development by the world leaders in air movement technology. By setting and achieving

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT AIR COMFORT FIRE SAFETY AIR MOVEMENT MAXFAN COMPAC» OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL INTRODUCING THE MAXFAN COMPAC THE NEW MAXFAN COMPAC DESIGNED FOR THE KITCHEN CANOPY MARKET

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

BIFLOW SB CON Product Brochure

BIFLOW SB CON Product Brochure BIFLOW SB CON Brochure Available for next day delivery with ELTA SELECT Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

CASED AXIAL BIFURCATED SERIES 33

CASED AXIAL BIFURCATED SERIES 33 76 CASED AXIA BIFURCATED SERIES 33 PRODUCT FACTS Air flow up to 0.95 m 3 /s Static pressures up to 380 Pa Suitable for temperatures up to 200 C Series 33 is cost effective solution to Bifurcated applications

More information

Novenco axial flow fans. ZerAx - Standard January 2010

Novenco axial flow fans. ZerAx - Standard January 2010 Novenco axial flow fans ZerAx - Standard January 2010 Product facts Product The Novenco ZerAx series of axial flow fans uses innovative design to reduce power consumption by improving efficiency. As an

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

Wide performance ranges are obtained by using three impeller designs to suit all types of applications. Roof Mounted Fans Section 6 Wide performance ranges are obtained by using three impeller designs to suit all types of applications. The roof extract units are designed to satisfy the consultants functional

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

NOVENCO FAN CATALOGUE

NOVENCO FAN CATALOGUE NOVENCO FAN CATALOGUE WWW.NOVENCO-MARINE.COM ZERAX AXIAL FLOW FANS PRODUCT The Novenco ZerAx series of axial flow fans use innovative design to reduce power consumption and to better fan efficiency. The

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

TURBOFLOW TF Contra Rotating Axial Flow Fan

TURBOFLOW TF Contra Rotating Axial Flow Fan TURBOFLOW TF Contra Rotating Axial Flow Fan Select models available for next day delivery TURBOFLOW TF Overview 5 standard sizes from 450mm to 630mm Air volume flow rates up to 4.6 m³/s Static pressures

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

LC/SC. Long & Short Cased Axial Fans

LC/SC. Long & Short Cased Axial Fans LC/SC Long & Short Cased xial Fans LC/SC contents introduction features & benefits specification performance dimensional data mounting silencer data accessories inverters & DCV controllers additional

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

HT SERIES SMOKE VENTING EQUIPMENT

HT SERIES SMOKE VENTING EQUIPMENT FIRE SAFETY AIR MOVEMENT HT SERIES SMOKE VENTING EQUIPMENT HT200 C OR HIGHER FOR 2 HOURS» SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS PART NO. 412111 CONTENTS GENERAL SAFETY WARNING PARAGRAPHS 1

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

ifan Copford Box Range

ifan Copford Box Range Setting the Standard for Energy Management ifan Copford Box Range Energy Management by demand Introduction The ifan is designed to offer environmental management through a controllable solution for the

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE 83 PLASTIC TUBE FANS - ESPADA FEATURES mm to 315 mm diameter Air flow up to.35 m 3 /s Static pressures up to 58 Pa Plastic cased centrifugal fan Low noise levels Corrosion resistant design Easy electrical

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels ASA SINGE INET ENTRIUGA AN with Airfoil heels ASA Series SINGE INET ENTRIUGA AN with Airfoil heels Kruger Ventilation Industries certifies that the ASA series shown herein is licensed to bear the AMA Seal.

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Highline 260i EC Waterside Fan Coil Unit

Highline 260i EC Waterside Fan Coil Unit Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable

More information

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIFUGA FAN with Backward heels BSB Series SINGE INET ENTRIFUGA FAN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

AXUS HIGH TEMPERATURE AXIAL FANS

AXUS HIGH TEMPERATURE AXIAL FANS WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 029 2085 8 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and

More information

RECTANGULAR EXTRACT FANS

RECTANGULAR EXTRACT FANS RECTANGULAR EXTRACT FANS Wide duty range 0.05m 3 /sec to 3.2m 3 /sec Horizontal or vertical mounting Quick and easy to install VES EXTRACT FANS part of a complete range of innovative, flexible products

More information

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013 ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame Australian Version October 2013 ODP SERIES (OPEN DRIP PROOF) PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS, C280M TO C355LB FRAME

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour 1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

Novenco Tunnel Fans. Novax October 2007

Novenco Tunnel Fans. Novax October 2007 Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and

More information

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.

More information