CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

Size: px
Start display at page:

Download "CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS"

Transcription

1 - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate separate high grade die-cast aluminium blades locked within a pressed sheet steel hub. Suitable for horizontal or vertical mounting installation. All models are available in both short and long versions. version (L) include an exterior terminal box, (LP) includes an inspection door and 1600 models include, as a standard version, external terminal box. s Available, depending upon the model: - with three phase motors in 2, 4 or 6 poles. - with three phase two speed motors 2/4,4/8 or 6/12 poles. All the motors are IP55, Class F insulation Electrical supplies: Three phase / /60* Hz up to 3 kw. (*Check Easyvent for 60Hz available models) Three phase V-50Hz, for higher motors and two speed motors. Performance curves To select TGT fans refer to S&P selection software Easyvent. (L version) TGT 1400/1600 Cylindrical cased axial flow fans TGT 147

2 Corrosion resistance Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. Support motor Manufactured from galvanised sheet steel. (s from 400 to 800). Aerodynamic motor support Aerodynamic design of the motor support to optimise airflow performances. (s from 900 to 1250). support (1400 and 1600 mm diameter): Welded on the fan. The whole assembly with a corrosion resistant hot dip galvanised finish. Impeller dynamically balanced Impeller dynamically balanced, according to ISO 1940 standard, providing vibration free operation. Wide blade design: higher pressure Blade design to ensure the highest efficient airflow performances. Configuration 1: 400 to 800/6 models. Configuration 2: 800/9 to 1600 models. Terminal box External terminal box, situated out of the airflow (long standard versions). REFERENCE T G T / / 10 / B L - 2,2 kw Product range. 2 - Number of poles. 3 - s*. 4 - Number of blades. 5 - Blade pitch angle. 6 - Airflow direction: B (Impeller - ) / A ( - Impeller). 7 - Blank: With short without external terminal box. K: With short with external terminal box. L: With external terminal box and view finder. LP: Without external terminal box and with inspection door. LPK: with inspection door and terminal box 8 -. * For the 1400 and 1600 mm diameter fan we replace the last 0 by a number indicating the hub diameter. 148 Cylindrical cased axial flow fans TGT

3 CYLINDRICAL CASED AXIAL FLOW ATEX FANS TGT ATEX Series ATEX version LP Large inspection door fitted on cased models for ATEX versions, that enables access to the motor terminal box for electrical connection. Ex motor versions Ex versions in accordance to ATEX Directive. Specific applications Range of cylindrical cased axial flow ATEX fans, from 400 to 1250 mm diameters. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate separate high grade diecast aluminium blades locked within a pressed sheet steel hub. Suitable for horizontal or vertical mounting installation. All models are available in both short and long (LP) versions. versions include a large inspection door. s Available, depending upon the model: - with three phase motors in 2, 4 or 6 poles. All the motors are IP55, Class F insulation Electrical supplies: Three phase 230/400V-50Hz up to 3kW. Three phase 400V-50Hz, for higher motors and two speed motors. (See characteristics chart). ATEX TGT ATEX versions available for 3 phase models. For ambient working temperatures from -20ºC to +40ºC. - ATEX Flameproof - Gas In standard ATEX version flameproof motors are without thermal protection. If used with frequency inverter, flameproof motors with a PTC-type thermal protection must be specified at order. II 2G Ex d IIB T4 II 2G Ex d IIB+H2 T4 (with motor Ex d IIC T4) - ATEX Increased safety - Gas II 2G Ex e II T3 - ATEX - Dust In standard ATEX version, ATEX motors for dust are without thermal protection. If used with frequency inverter, ATEX motors for dust with a PTC-type thermal protection must be specified at order. Combustable flyings and non conductive dust: II 3D Ex tc IIIB T125ºC Conductive dust: II 3D Ex tc IIIC T125ºC ( with motor IP65) * TGT ATEX Flameproof models 400 and 450mm diameter only available long case LP version. ** TGT ATEX Flameproof models 500 to 1250mm diameter available short case and long case version LP (not available version K or L). To select TGT ATEX refer to performance curves for THGT, or Easyvent. Note electrical data may vary for ATEX motors. Additional information Standard air direction: Form B configuration (impeller over motor). On request Air direction: Form A configuration (motor over impeller). Refer to Easyvent for selection. Cylindrical cased axial flow fans TGT 149

4 TECHNICAL CHARACTERISTICS - 2 poles TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ /-2, ,2 4, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ /-9, ,2 16, TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ /-9, ,2 16, TGT/ /-11 L ,9 183 TGT/ /-15 L ,4 186 TGT/ /-18,5 L ,5 33,3 199 TECHNICAL CHARACTERISTICS - 4 poles TGT/ /-0, ,25 0, TGT/ /-0, ,25 0, TGT/ /-0, ,37 1, TGT/ /-0, ,55 1, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ / , TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-1, ,5 3, TGT/ /-2, ,2 4, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, Cylindrical cased axial flow fans TGT

5 TECHNICAL CHARACTERISTICS - 4 poles (CONTINUATION) TGT/ /-2, ,2 4, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ /-5, ,5 10, TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-7, ,5 13, TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / Cylindrical cased axial flow fans TGT 151

6 TECHNICAL CHARACTERISTICS - 4 poles (CONTINUATION) TGT/ /-18, ,5 34, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TGT/ / TECHNICAL CHARACTERISTICS - 6 poles TGT/ /-0, ,37 1, TGT/ /-0, ,55 1, TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-0, ,37 1, TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, Cylindrical cased axial flow fans TGT

7 TECHNICAL CHARACTERISTICS - 6 poles (CONTINUATION) TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-0, ,55 1, TGT/ /-0, ,75 1, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ /-1, ,1 2, TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ / , TGT/ /-2, ,2 5, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ / , TGT/ /-1, ,5 3, TGT/ /-2, ,2 5, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ /-2, ,2 5, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ / , TGT/ /-5, ,5 12, TGT/ /-7, ,5 14, TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ /-7, ,5 14, TGT/ / , TGT/ / , TGT/ /-18, ,5 37, Cylindrical cased axial flow fans TGT 153

8 TECHNICAL CHARACTERISTICS - 6 poles (CONTINUATION) TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ / , TGT/ / , TGT/ /-18, ,5 37, TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / , TGT/ / , TGT/ / , TGT/ / TGT/ / TGT/ / TGT/ / TECHNICAL CHARACTERISTICS - 2/4 poles TGT/2/ /-1,1/0, ,1 0,25 2,5 0, TGT/2/ /-1,5/0, ,5 0,35 3,8 0,9 40,1 46,1 TGT/2/ /-2,2/0, ,2 0,6 4,8 1,5 41,3 47,3 TGT/2/ /-1,1/0, ,1 0,25 2,5 0,66 44,4 44,4 TGT/2/ /-1,5/0, ,5 0,35 3,8 0,9 47,5 47,5 TGT/2/ /-2,2/0, ,2 0,6 4,8 1,5 48,7 48,7 TGT/2/ /-3/0, ,8 6,6 1, TGT/2/ /-1,5/0, ,5 0,35 3,8 0, TGT/2/ /-2,2/0, ,2 0,6 4,8 1,5 49,2 49,2 TGT/2/ /-3/0, ,8 6,6 1,7 58,5 58,5 TGT/2/ /-4,5/1, ,5 1,3 9,9 3, Cylindrical cased axial flow fans TGT

9 TECHNICAL CHARACTERISTICS - 2/4 poles (CONTINUATION) TGT/2/ /-1,5/0, ,5 0,35 3,8 0, TGT/2/ /-2,2/0, ,2 0,6 4,8 1,5 49,2 49,2 TGT/2/ /-3/0, ,8 6,6 1,7 58,5 58,5 TGT/2/ /-4,5/1, ,5 1,3 9,9 3, TGT/2/ /-3/0, ,8 6,6 1,7 65,5 82,5 TGT/2/ /-4,5/1, ,5 1,3 9,9 3, TGT/2/ /-6/1, ,6 13,2 3, TGT/2/ /-8,3/1, ,3 1,7 15,4 4, TGT/2/ /-9/2, ,5 18,6 5, TGT/2/ /-4,5/1, ,5 1,3 9,9 3, TGT/2/ /-6/1, ,6 13,2 3, TGT/2/ /-8,3/1, ,3 1,7 15,4 4, TGT/2/ /-9/2, ,5 18,6 5, TGT/2/ /-10/2 L ,8 136 TGT/2/ /-16/3,2 L ,2 28, TGT/2/ /-19/4,5 L ,5 34,9 8,6 160 TECHNICAL CHARACTERISTICS - 4/8 poles TGT/4/ /-0,37/0, ,37 0,09 1,1 1,2 32,6 38,6 TGT/4/ /-0,37/0, ,37 0,09 1,1 1, TGT/4/ /-0,55/0, ,55 0,13 1,8 0,65 42,5 42,5 TGT/4/ /-0,55/0, ,55 0,13 1,8 0, TGT/4/ /-0,75/0, ,75 0,12 2,3 0,9 44,9 44,9 TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-0,37/0, ,37 0,09 1,1 1,2 47,5 64,5 TGT/4/ /-0,55/0, ,55 0,13 1,8 0, TGT/4/ /-0,75/0, ,75 0,12 2,3 0,9 51,9 68,9 TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-0,55/0, ,55 0,13 1,8 0, TGT/4/ /-0,75/0, ,75 0,12 2,3 0,9 58,9 73,9 TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-0,55/0, ,55 0,13 1,8 0, TGT/4/ /-0,75/0, ,75 0,12 2,3 0,9 53,9 77,9 TGT/4/ /-1,1/0, ,1 0,26 2,8 1, TGT/4/ /-1,7/0, ,7 0,35 4 1, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, Cylindrical cased axial flow fans TGT 155

10 TECHNICAL CHARACTERISTICS - 4/8 poles (CONTINUATION) TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-2,3/0, ,3 0,5 5,2 1, TGT/4/ /-3/0, ,65 6,8 2, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-4/0, ,75 8,7 3, TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-5/ ,9 3, TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-17/4, ,3 33,4 12, TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-6,8/1, ,8 1,4 13,7 5, TGT/4/ /-8,4/2, ,4 2,05 16,6 6, TGT/4/ /-10,5/2, ,5 2,2 21 7, TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-17/4, ,3 33,4 12, TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-50/ Cylindrical cased axial flow fans TGT

11 TECHNICAL CHARACTERISTICS - 4/8 poles (CONTINUATION) TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-50/ TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-50/ TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-130/ , TGT/4/ /-160/ TGT/4/ /-15,5/2, ,5 2,7 30 9, TGT/4/ /-17/3, , TGT/4/ /-22/4, , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-50/ TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-50/ TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-33/ TGT/4/ /-42/ TGT/4/ /-50/ TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-130/ , TGT/4/ /-160/ TGT/4/ /-42/ TGT/4/ /-50/ TGT/4/ /-55/14, , , TGT/4/ /-68/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-130/ , TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-130/ , TGT/4/ /-160/ TGT/4/ /-80/ , TGT/4/ /-110/ , TGT/4/ /-130/ , TGT/4/ /-160/ TECHNICAL CHARACTERISTICS - 4/6 poles TGT/4/ /-0,5/0, ,5 0,19 1,4 0,7 42,5 42,5 TGT/4/ /-0,66/0, ,66 0,25 1,75 0,8 43,5 43,5 TGT/4/ /-0,5/0, ,5 0,19 1,4 0, TGT/4/ /-0,66/0, ,66 0,25 1,75 0, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-0,5/0, ,5 0,19 1,4 0, TGT/4/ /-0,66/0, ,66 0,25 1,75 0, TGT/4/ /-0,78/0, ,78 0, TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, Cylindrical cased axial flow fans TGT 157

12 TECHNICAL CHARACTERISTICS - 4/6 poles (CONTINUATION) TGT/4/ /-0,66/0, ,66 0,25 1,75 0, TGT/4/ /-0,78/0, ,78 0, TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-0,66/0, ,66 0,25 1,75 0, TGT/4/ /-0,78/0, ,78 0, TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-0,78/0, ,78 0, TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-1/0, ,3 2,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-1,5/0, ,5 0,45 3,5 1, TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-2,5/0, ,5 0,8 5,5 2, TGT/4/ /-3/ ,85 3, TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-4,5/1, ,5 1,5 9,2 5, TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , Cylindrical cased axial flow fans TGT

13 TECHNICAL CHARACTERISTICS - 4/6 poles (CONTINUATION) TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-6/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-50/ , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-50/ , TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-10,5/3, ,5 3,5 21 8, TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-14/4, , TGT/4/ /-16/ , TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-20/6, , TGT/4/ /-23/7, , TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-50/ , TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-42/ TGT/4/ /-50/ , TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-125/ , TGT/4/ /-50/ , TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-125/ , TGT/4/ /-145/ TGT/4/ /-30/ , TGT/4/ /-34/ TGT/4/ /-42/ TGT/4/ /-50/ , TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , Cylindrical cased axial flow fans TGT 159

14 TECHNICAL CHARACTERISTICS - 4/6 poles (CONTINUATION) TGT/4/ /-70/ , TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-125/ , TGT/4/ /-145/ TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-125/ , TGT/4/ /-145/ TGT/4/ /-80/ , TGT/4/ /-95/ TGT/4/ /-115/ , TGT/4/ /-125/ , TGT/4/ /-145/ TECHNICAL CHARACTERISTICS - 6/12 poles TGT/6/ /-0,4/0, ,4 0,08 1,2 0, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-0,4/0, ,4 0,08 1,2 0, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-0,4/0, ,4 0,08 1,2 0, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-0,4/0, ,4 0,08 1,2 0, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-1,1/0, ,1 0,18 3,2 1, TGT/6/ /-0,4/0, ,4 0,08 1,2 0, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-1,1/0, ,1 0,18 3,2 1, TGT/6/ /-0,75/0, ,75 0,12 2,4 0, TGT/6/ /-1,1/0, ,1 0,18 3,2 1, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, Cylindrical cased axial flow fans TGT

15 TECHNICAL CHARACTERISTICS - 6/12 poles (CONTINUATION) TGT/6/ /-1,5/0, ,5 0,25 4 1, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-4/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, TGT/6/ /-11/1, ,8 26, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, TGT/6/ /-11/1, ,8 26, TGT/6/ /-15/2, ,5 33,4 10, TGT/6/ /-2,2/0, ,2 0,37 5,6 2, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, TGT/6/ /-11/1, ,8 26, TGT/6/ /-3/0, ,55 8 3, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, TGT/6/ /-11/1, ,8 26, TGT/6/ /-15/2, ,5 33,4 10, TGT/6/ /-4/0, ,65 10,4 3, TGT/6/ /-5,5/ ,5 1 14,1 5, TGT/6/ /-7,5/1, ,5 1,3 17,5 5, TGT/6/ /-11/1, ,8 26, TGT/6/ /-15/2, ,5 33,4 10, TGT/6/ /-18,5/ ,5 3 38,2 11, TGT/6/ /-25/4, ,5 52,2 16, Cylindrical cased axial flow fans TGT 161

16 DIMENSIONS AC AL N x ØF ØD ØB ØE ØE ØD ØB C max TGT short TGT long TGT ATEX-500 to TGT ATEX-1250 TGT ATEX-400 to TGT ATEX-1250 long (LP) AC AL NxØF NxØF H ØD GC ØB ØE ØD ØB ØE GL TGT 1400 and TGT 1600 C TGT 1400 and TGT 1600 long (LP) AC AL B C D E F GC GL N * * 1275* *Dimension corresponding to the largest motor available for the range. For more detailed information depending on the working point, please consult Easyvent. 162 Cylindrical cased axial flow fans TGT

17 MOUNTING ACCESSORIES Circular duct matching flange Bellmouth protection guard Circular flexible connector Inlet grille guard Outlet grille guard 400 ARO BRIDA TGT/THGT-400 N EMB- 400T ACOPEL F /160 N DEF.ASP.TGT/THGT-400 (impeller side) DEF.DES.TGT/THGT-400 (motor side) 450 ARO BRIDA TGT/THGT-450 N EMB- 450T ACOPEL F /160 N DEF.ASP.TGT/THGT-450 (impeller side) DEF.DES.TGT/THGT-450 (motor side) 500 ARO BRIDA TGT/THGT-500 N EMB- 500T ACOPEL F /160 N DEF.ASP.TGT/THGT-500 (impeller side) DEF.DES.TGT/THGT-500 (motor side) 560 ARO BRIDA TGT/THGT-560 N EMB- 560T ACOPEL F /160 N DEF.ASP.TGT/THGT-560 (impeller side) DEF.DES.TGT/THGT-560 (motor side) 630 ARO BRIDA TGT/THGT-630 N EMB- 630T ACOPEL F /160 N DEF.ASP.TGT/THGT-630 (impeller side) DEF.DES.TGT/THGT-630 (motor side) 710 ARO BRIDA TGT/THGT-710 N EMB- 710T ACOPEL F /180 N DEF.ASP.TGT/THGT-710 (impeller side) DEF.DES.TGT/THGT-710 (motor side) 800 ARO BRIDA TGT/THGT-800 N EMB- 800T ACOPEL F /180 N DEF.ASP.TGT/THGT-800 (impeller side) DEF.DES.TGT/THGT-800 (motor side) 900 ARO BRIDA TGT/THGT-900 N EMB- 900T ACOPEL F /180 N DEF.ASP.TGT/THGT-900 (impeller side) DEF.DES.TGT/THGT-900 (motor side) 1000 ARO BRIDA TGT/THGT-1000 N EMB- 1000T ACOPEL F /180 N DEF.ASP.TGT/THGT-1000 (impeller side) DEF.DES.TGT/THGT-1000 (motor side) 1120 ARO BRIDA TGT/THGT-1120 N EMB- 1120T ACOPEL F /200 N DEF.ASP.TGT/THGT-1120 (impeller side) DEF.DES.TGT/THGT-1120 (lado motor) 1250 ARO BRIDA TGT/THGT-1250 N EMB- 1250T ACOPEL F /200 N DEF.ASP.TGT/THGT-1250 (impeller side) DEF.DES.TGT/THGT-1250 (motor side) 1400 ARO BRIDA TGT/THGT-1400 N EMB- 1400T ACOPEL F /200 N DEF.ASP.TGT/THGT-1400 (impeller side) DEF.DES.TGT/THGT-1400 (motor side) 1600 ARO BRIDA TGT/THGT-1600 N EMB- 1600T ACOPEL F /200 N DEF.ASP.TGT/THGT-1600 (impeller side) DEF.DES.TGT/THGT-1600 (motor side) Support feet (Horizontal) Support feet (Vertical) Back draft shutter* Back draft shutter Circular sound attenuator Flexible connector ATEX 400 PIE SOP.TGT/THGT-400 PIE SOP.TGT/THGT-400 V CLAR-400 SIL CZ 400 SIL CZO 400 ACOPEL EX 400/ 160 N 450 PIE SOP.TGT/THGT-450 PIE SOP.TGT/THGT-450 V CLAR-450 SIL CZ 450 SIL CZO 450 ACOPEL EX 450/ 160 N 500 PIE SOP.TGT/THGT-500 PIE SOP.TGT/THGT-500 V CLAR-500 SIL CZ 500 SIL CZO 500 ACOPEL EX 500/ 160 N 560 PIE SOP.TGT/THGT-560 PIE SOP.TGT/THGT-560 V CLAR 560 SIL CZ 560 SIL CZO 560 ACOPEL EX 560/ 160 N 630 PIE SOP.TGT/THGT-630 PIE SOP.TGT/THGT-630 V CLAR 630 SIL CZ 630 SIL CZO 630 ACOPEL EX 630/ 160 N 710 PIE SOP.TGT/THGT-710 PIE SOP.TGT/THGT-710 V CLAR 710 SIL CZ 710 SIL CZO 710 ACOPEL EX 710/ 180 N 800 PIE SOP.TGT/THGT-800 PIE SOP.TGT/THGT-800 V CLAR 800 SIL CZ 800 SIL CZO 800 ACOPEL EX 800/ 180 N 900 PIE SOP.TGT/THGT-900 PIE SOP.TGT/THGT -900 V CLAR 900 SIL CZ 900 SIL CZO 900 ACOPEL EX 900/ 180 N 1000 PIE SOP.TGT/THGT-1000 PIE SOP.TGT/THGT-1000 V CLAR 1000 SIL CZ 1000 SIL CZO 1000 ACOPEL EX 1000/ 180 N 1120 PIE SOP. TGT/THGT-1120 PIE SOP. TGT/THGT-1120 V CLAR 1120 SIL CZ 1120 SIL CZO 1120 ACOPEL EX 1120/ 200 N 1250 PIE SOP.TGT/THGT-1250 PIE SOP.TGT/THGT-1250 V CLAR 1250 SIL CZ 1250 SIL CZO 1250 ACOPEL EX 1250/ 200 N 1400 PIE SOP.TGT/THGT-1400 PIE SOP.TGT/THGT-1400 V CLAR 1400 SIL CZ 1400 SIL CZO 1400 ACOPEL EX 1400/ 200 N 1600 PIE SOP.TGT/THGT-1600 PIE SOP.TGT/THGT-1600 V CLAR 1600 SIL CZ 1600 SIL CZO 1600 ACOPEL EX 1600/ 200 N Antivibration mounts (AM) Divide the total weight of the fan by 4, as you need 4 antivibration mounts per unit, and then look for the appropriate model according to their load. (See: Mounting accessories) See complete information on the Mounting Accesories. * Only horizontal mounting. Cylindrical cased axial flow fans TGT 163

18 INSTALLATION OF THE MOUNTING ACCESSORIES OUTLET INLET Outlet grille Inlet grille air-stream direction Flexible flange connector Flexible flange connector Ducting Matching flange Support feet Matching flange Ducting Back draft shutter Inlet adapter protection guard See complete information on the Mounting Accesories. FITTING ANTI-VIBRATION MOUNTS IN THE SHORT CASING MODELS L min. R min. When fitting anti-vibration mountings, short models, it is recommended they are fitted to a suitable support frame (not supplied by S&P) following the minimum distances as specified in the table. TGT L min. R min. Total Cylindrical cased axial flow fans TGT

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped

More information

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

SERIES R - MD MOR & GOR

SERIES R - MD MOR & GOR SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS ATEX LOG ASE AXAL FLOW FA ALATO ATEX ucted Axial Flow Fans suitable to exhaust/supply air in presence of chemical processes, water and sewage treatment, material and gas waste, dust and paint extraction,

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

BIFURCATED AXIAL FANS

BIFURCATED AXIAL FANS BFURATE AXAL FAS SB (YL) ALATO SB (O) Bifurcated axial fans suitable to move air in hostile applications, for example in case of dust and chemical substances in heavy industrial, boiler houses, corrosive

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

COMPACT Series type HCFB / HCFT (Plastic impellers)

COMPACT Series type HCFB / HCFT (Plastic impellers) Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification HCH/ATEX HCT/ATEX HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification Circular axial fans (HCH) or Long-cased fans (HCT) with

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

"LCA"- long cased axial fan

LCA- long cased axial fan "LCA"- long cased axial fan Long cased axial fans for industrial/commercial use Thirteen sizes - from 310mm to 1250mm diameter Airflow from 2,200 to 80,000m 3 /hr Single or Three Phase 2, 4 or 6 pole motors

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

JM Aerofoil Bifurcated Fans

JM Aerofoil Bifurcated Fans JM Aerofoil Bifurcated Fans JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection

More information

CASED 24 Designed for emergency ventilation of hot fire smoke applications 300 C or 400 C for two hours operation, CE marked to EN12101-3 2002 All casings are hot dipped galvanised Sizes from 315mm to

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

BIFLOW SB CON Product Brochure

BIFLOW SB CON Product Brochure BIFLOW SB CON Brochure Available for next day delivery with ELTA SELECT Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h For ATEX zone 1/1, 22/22 and 21/21 Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. HCH HCH Extremely robust wall-mounted, axial or tubular fans Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. Fan: Airflow direction from

More information

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options

More information

NOVENCO FAN CATALOGUE

NOVENCO FAN CATALOGUE NOVENCO FAN CATALOGUE WWW.NOVENCO-MARINE.COM ZERAX AXIAL FLOW FANS PRODUCT The Novenco ZerAx series of axial flow fans use innovative design to reduce power consumption and to better fan efficiency. The

More information

Oil/air cooler BLK ATEX-3GD

Oil/air cooler BLK ATEX-3GD FluidControl Oil/air cooler BLK ATEX-3GD Drives and hydraulic aggregates are also used in explosive areas in machine construction or raw material production. In hydraulic systems oil transfers power and

More information

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: AATVP HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: Accessories Fan made of Fe36 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

BATHROOM EXTRACT FANS DECOR-100 Series

BATHROOM EXTRACT FANS DECOR-100 Series DECOR-1 Series Range of axial extractors with airflow rates of 1 m 3 /h, for connection to 1 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information