CYLINDRICAL CASED AXIAL FLOW FANS

Size: px
Start display at page:

Download "CYLINDRICAL CASED AXIAL FLOW FANS"

Transcription

1 - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate separate high grade die-cast aluminium blades locked within a pressed sheet steel hub. Suitable for horizontal or vertical mounting installation. All models are available in both short and long versions. versions (L) include an exterior terminal box. s Available, depending upon the model: - with three phase motors in 2, 4 or 6 poles. - with three phase two speed motors 2/4,4/8 or 6/12 poles. All the motors are IP55, Class F insulation Electrical supplies: Three phase 230/400V-50Hz up to 3kW. Three phase 400V-50Hz, for higher motors and two speed motors. (See characteristics chart). (L version) Highly versatile range due to different number of available blades and adjustable pitch angles Impellers with 3, 6 or 9 blades with adjustable pitch angles, allowing the most optimum selection to achieve with every kind of installation requirements.

2 Corrosion resistance Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. Support motor Manufactured from electrowelded sheet steel. (s from 400 to 800). Aerodynamic motor support Aerodynamic design of the motor support to optimise airflow performances. (s from 900 to 1250). Impeller dynamically balanced Impeller dynamically balanced, according to ISO 1940 standard, providing vibration free operation. Wide blade design: higher pressure Blade design to ensure the highest efficient airflow performances. Configuration 1: 400 to 800/6 models. Configuration 2: 800/9 to 1250 models. Terminal box External terminal box, situated out of the airflow (long standard versions). Reference T G T / / 10 / B L - 2,2 kw Product range. 2 - Number of poles. 3 - Diameters. 4 - Number of blades. 5 - Blade pitch angle. 6 - Airflow direction: B (Impeller - ) / A ( - Impeller). 7 - Blank: With short without external terminal box. K: With short with external terminal box. L: With external terminal box and view finder. LP: Without external terminal box and with inspection door s for TGT product range 1-SPEED MOTORS 2-SPEED MOTORS 2 POLES 1,1 1,5 2, ,5 7,5 9, POLES 0,25 0,37 0,55 0,75 1,1 1,5 2, ,5 7, , POLES 0,37 0,55 0,75 1,1 1,5 2, ,5 7, ,5 22 2/4 POLES 1,1/0,25 1,5/0,35 2,2/0,6 3/0,8 4,5/1,3 6/1,6 8,3/1,7 9/2,5 13,5/3,3 19/4,5 4/8 POLES 0,25/0,06 0,37/0,09 0,55/0,13 0,75/0,12 1,1/0,26 1,7/0,35 2,3/0,5 3/0,65 4/0,75 5,5/1,1 8,4/2,05 10,5/2,2 15,5/2,7 22/4,4 33/8 42/10 50/11 6/12 POLES 0,4/0,08 0,75/0,12 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 4/0,65 5,5/1 7,5/1,3 11/1,8 15/2,5 18,5/3 25/4,5 NOTE: For 2 speed motors, the s may have small variations depending on the motor manufacturer.

3 CYLINDRICAL CASED AXIAL FLOW ATEX FANS TGT ATEX Series ATEX version LP Large inspection door fitted on cased models for ATEX versions, that enables access to the motor terminal box for electrical connection. Explosion proof versions Explosion proof versions in accordance to ATEX Directive. Range of cylindrical cased axial flow atex fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate separate high grade diecast aluminium blades locked within a pressed sheet steel hub. Suitable for horizontal or vertical mounting installation. All models are available in both short and long (LP) versions. versions include a large inspection door. s Available, depending upon the model: - with three phase motors in 2, 4 or 6 poles. All the motors are IP55, Class F insulation Electrical supplies: Three phase 230/400V-50Hz up to 3kW. Three phase 400V-50Hz, for higher motors and two speed motors. (See characteristics chart). ATEX ATEX versions available for 3 phase models. For ambient working temperatures from -20ºC to +40ºC. - ATEX Flamproof - Gas II 2G Ex d IIC T4 II 2G Exd IIB T5 - ATEX Increased safety - Gas II 2G Exe II T3 - ATEX - Dust II 3D Ex td 125ºC * TGT ATEX Flameproof models 400 and 450mm diameter only available long case LP version. ** TGT ATEX Flameproof models 500 to 1250mm diameter available short case and long case version LP (not available version K or L). To select TGT ATEX refer to performance curves for THGT, or Easyvent. Note electrical data may vary for ATEX motors. Additional information Standard air direction: form (B) configuration (impeller over motor). On request Air direction: form configuration (motor over impeller). Specific applications To check the curves from TGT ATEX product range, please refer to THGT performance curves.

4 TGT 1 speed models Technical characteristics - 2 poles rpm Before installation check that the product electrical characteristics listed on the data plate label (voltage,, frequency, etc.) match those of the intended electrical supply. TGT/ /-1,1 1,1 4,1 2, TGT/ /-1,5 1,5 5,5 3, TGT/ /-2,2 2,2 8,0 4, TGT/ /-2,2 2,2 8,0 4, TGT/ / ,3 5, TGT/ /-2,2 2,2 8,0 4, TGT/ / ,3 5, TGT/ /-4 4-7, TGT/ / ,3 5, TGT/ /-4 4-7, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ /-9,2 9,2-17, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ /-9,2 9,2-17, TGT/ /-11 L 11-20,4-152 TGT/ /-15 L 15-27,6-160 TGT/ /-18,5 L 18,5-33,7-172 Technical characteristics - 4 poles rpm TGT/ /-0,25 0,25 1,4 0, TGT/ /-0,37 0,37 1,8 1, TGT/ /-0,55 0,55 2,2 1, TGT/ /-0,55 0,55 2,2 1, TGT/ /-0,75 0,75 2,8 1, TGT/ /-1,1 1,1 4,2 2, TGT/ /-0,55 0,55 2,2 1, TGT/ /-0,75 0,75 2,8 1, TGT/ /-1,1 1,1 4,2 2, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ /-0,75 0,75 2,8 1, TGT/ /-1,1 1,1 4,2 2, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-0,75 0,75 2,8 1, TGT/ /-1,1 1,1 4,2 2, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-1,1 1,1 4,2 2, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-4 4-8, TGT/ /-1,1 1,1 4,2 2, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-1,5 1,5 5,7 3, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ /-2,2 2,2 8,1 4, TGT/ / ,7 6, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ / , TGT/ / ,

5 Technical characteristics - 4 poles rpm (continuation) TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ / , TGT/ / , TGT/ / ,7 6, TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ / , TGT/ /-4 4-8, TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT/ /-5,5 5,5-10, TGT/ /-7,5 7,5-14, TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT/ /-7,5 7,5-14, TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT/ / , TGT/ / , TGT/ / , Technical characteristics - 6 poles rpm TGT/ /-0,37 0,37 1,8 1, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,37 0,37 1,8 1, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,75 0,75 3,4 2, TGT/ /-1,1 1,1 4,8 2, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,75 0,75 3,4 2, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,75 0,75 3,4 2, TGT/ /-1,1 1,1 4,8 2, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ /-1,1 1,1 4,8 2, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,75 0,75 3,4 2, TGT/ /-1,1 1,1 4,8 2, TGT/ /-0,55 0,55 2,6 1, TGT/ /-0,75 0,75 3,4 2, TGT/ /-1,1 1,1 4,8 2, TGT/ /-1,5 1,5 6,5 3, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-4 4-9,

6 Technical characteristics - 6 poles rpm (continuation) TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-5,5 5,5-12, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-4 4-9, TGT/ /-1,5 1,5 6,5 3, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-4 4-9, TGT/ /-5,5 5,5-12, TGT/ /-7,5 7,5-15, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-4 4-9, TGT/ /-5,5 5,5-12, TGT/ /-7,5 7,5-15, TGT/ /-2,2 2,2 9,2 5, TGT/ / ,7 7, TGT/ /-4 4-9, TGT/ /-5,5 5,5-12, TGT/ /-7,5 7,5-15, TGT/ / , TGT/ /-4 4-9, TGT/ /-5,5 5,5-12, TGT/ /-7,5 7,5-15, TGT/ / , TGT/ / , TGT/ /-5,5 5,5-12, TGT/ /-7,5 7,5-15, TGT/ / , TGT/ / , TGT/ /-18,5 18,5-35, TGT/ / , TGT 2 speed models Technical characteristics - 2/4 poles Before installation check that the product electrical characteristics listed on the data plate label (voltage,, frequency, etc.) match those of the intended electrical supply. motor TGT/2/ /-1,1/0,3* 1,1 0,25 2,5 0, TGT/2/ /-1,5/0,4* 1,5 0,35 3,8 0, TGT/2/ /-2,2/0,6* 2,2 0,6 4,8 1, TGT/2/ /-2,2/0,6 2,2 0,6 4,8 1, TGT/2/ /-3/0,8 3 0,8 6,6 1, TGT/2/ /-2,2/0,6 2,2 0,6 4,8 1, TGT/2/ /-3/0,8 3 0,8 6,6 1, TGT/2/ /-4,5/1,3 4,5 1,3 9,9 3, * Some models are not ErP compliant. motor TGT/2/ /-3/0,8 3 0,8 6,6 1, TGT/2/ /-4,5/1,3* 4,5 1,3 9,9 3, TGT/2/ /-6/1,6 6 1,6 13,2 3, TGT/2/ /-8,3/1,7 8,3 1,7 15,4 4, TGT/2/ /-9/2,5 9 2,5 18,6 5, TGT/2/ /-6/1,6 6 1,6 13,2 3, TGT/2/ /-8,3/1,7 8,3 1,7 15,4 4, TGT/2/ /-9/2,5 9 2,5 18,6 5, TGT/2/ /-13,5/3,3 L 13,5 3,3 26,0 6,3-152 TGT/2/ /-19/4,5 L 19 4,5 34,9 8,6-172

7 Technical characteristics - 4/8 poles motor TGT/4/ /-0,25/0,06 0,25 0,06 0,8 0, TGT/4/ /-0,37/0,09* 0,37 0,09 1,1 1, TGT/4/ /-0,55/0,13* 0,55 0,13 1,8 0, TGT/4/ /-0,55/0,13* 0,55 0,13 1,8 0, TGT/4/ /-0,75/0,12* 0,75 0,12 2,3 0, TGT/4/ /-1,1/0,26* 1,1 0,26 2,8 1, TGT/4/ /-0,55/0,13* 0,55 0,13 1,8 0, TGT/4/ /-0,75/0,12 0,75 0,12 2,3 0, TGT/4/ /-1,1/0,26 1,1 0,26 2,8 1, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-0,75/0,12* 0,75 0,12 2,3 0, TGT/4/ /-1,1/0,26 1,1 0,26 2,8 1, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-0,75/0,12 0,75 0,12 2,3 0, TGT/4/ /-1,1/0,26 1,1 0,26 2,8 1, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-1,1/0,26 1,1 0,26 2,8 1, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-1,1/0,26 1,1 0,26 2,8 1, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-1,7/0,35 1,7 0,35 4,0 1, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 6,8 1,4 13,7 5, TGT/4/ /-8,4/2,05 5,5 1,1 11,0 3, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, motor TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-6,8/1,4 6,8 1,4 13,7 5, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-6,8/1,4 6,8 1,4 13,7 5, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-22/4,4 22 4,4 43,0 15, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-22/4,4 22 4,4 43,0 15, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, TGT/4/ /-10,5/2,2 10,5 2,2 21,0 7, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-22/4,4 22 4,4 43,0 15, TGT/4/ /-33/ ,0 21, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-22/4,4 22 4,4 43,0 15, TGT/4/ /-33/ ,0 21, TGT/4/ /-42/ ,0 27, TGT/4/ /-50/ ,0 28, TGT/4/ /-15,5/2,7 15,5 2,7 30,0 9, TGT/4/ /-22/4,4 22 4,4 43,0 15, TGT/4/ /-33/ ,0 21, TGT/4/ /-42/ ,0 27, TGT/4/ /-50/ ,0 28, TGT/4/ /-2,3/0,5 2,3 0,5 5,2 1, TGT/4/ /-3/0,65 3 0,65 6,8 2, TGT/4/ /-4/0,75 4 0,75 8,7 3, TGT/4/ /-5,5/1,1 5,5 1,1 11,0 3, TGT/4/ /-8,4/2,05 8,4 2,05 16,6 6, * Some models are not ErP compliant.

8 Technical characteristics - 6/12 poles motor TGT/6/ /-0,4/0,08 0,4 0,08 1,2 0, TGT/6/ /-0,75/0,12 0,75 0,12 2,4 0, TGT/6/ /-0,4/0,08 0,4 0,08 1,2 0, TGT/6/ /-0,75/0,12* 0,75 0,12 2,4 0, TGT/6/ /-1,1/0,18 1,1 0,18 3,2 1, TGT/6/ /-0,75/0,12 0,75 0,12 2,4 0, TGT/6/ /-0,75/0,12 0,75 0,12 2,4 0, TGT/6/ /-1,1/0,18 1,1 0,18 3,2 1, motor TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-5,5/1 5,5 1 14,1 5, TGT/6/ /-7,5/1,3 7,5 1,3 17,5 5, TGT/6/ /-0,75/0,12 0,75 0,12 2,4 0, TGT/6/ /-1,1/0,18* 1,1 0,18 3,2 1, TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-0,75/0,12 0,75 0,12 2,4 0, TGT/6/ /-1,1/0,18 1,1 0,18 3,2 1, TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-1,1/0,18* 1,1 0,18 3,2 1, TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-1,5/0,25 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-1,5/0,25* 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-1,5/0,25* 1,5 0,25 4,0 1, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-5,5/1* 5,5 1 14,1 5, * Some models are not ErP compliant. TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-5,5/1 5,5 1 14,1 5, TGT/6/ /-7,5/1,3 7,5 1,3 17,5 5, TGT/6/ /-2,2/0,37 2,2 0,37 5,6 2, TGT/6/ /-3/0,55 3 0,55 8,0 3, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-5,5/1 5,5 1 14,1 5, TGT/6/ /-7,5/1,3 7,5 1,3 17,5 5, TGT/6/ /-11/1,8 11 1,8 26,2 8, TGT/6/ /-4/0,65 4 0,65 10,4 3, TGT/6/ /-5,5/1 5,5 1 14,1 5, TGT/6/ /-7,5/1,3 7,5 1,3 17,5 5, TGT/6/ /-11/1,8 11 1,8 26,2 8, TGT/6/ /-15/2,5 15 2,5 33,4 10, TGT/6/ /-5,5/1 5,5 1 14,1 5, TGT/6/ /-7,5/1,3 7,5 1,3 17,5 5, TGT/6/ /-11/1,8 11 1,8 26,2 8, TGT/6/ /-15/2,5 15 2,5 33,4 10, TGT/6/ /-18,5/3 18,5 3 38,2 11, TGT/6/ /-25/4,5 25 4,5 52,2 16,

9 DIMENSIONS (mm) AC AL N x ØF ØD ØB ØE ØE ØB TGT short C max TGT long AC AL N x ØF N x ØF ØD ØB ØE ØD ØB ØE TGT ATEX-500 to TGT ATEX-1250 C max TGT ATEX-400 to TGT ATEX-1250 long (LP) AC AL B C D E F N

10 Mounting accessories Circular duct matching flange Bellmouth protection guard Circular flexible connector Inlet grille guard Outlet grille guard 400 ARO BRIDA TGT/THGT-400 N EMB- 400T ACOPEL F /160 N DEF.ASP.TGT/THGT-400 (impeller side) DEF.DES.TGT/THGT-400 (motor side) 450 ARO BRIDA TGT/THGT-450 N EMB- 450T ACOPEL F /160 N DEF.ASP.TGT/THGT-450 (impeller side) DEF.DES.TGT/THGT-450 (motor side) 500 ARO BRIDA TGT/THGT-500 N EMB- 500T ACOPEL F /160 N DEF.ASP.TGT/THGT-500 (impeller side) DEF.DES.TGT/THGT-500 (motor side) 560 ARO BRIDA TGT/THGT-560 N EMB- 560T ACOPEL F /160 N DEF.ASP.TGT/THGT-560 (impeller side) DEF.DES.TGT/THGT-560 (motor side) 630 ARO BRIDA TGT/THGT-630 N EMB- 630T ACOPEL F /160 N DEF.ASP.TGT/THGT-630 (impeller side) DEF.DES.TGT/THGT-630 (motor side) 710 ARO BRIDA TGT/THGT-710 N EMB- 710T ACOPEL F /180 N DEF.ASP.TGT/THGT-710 (impeller side) DEF.DES.TGT/THGT-710 (motor side) 800 ARO BRIDA TGT/THGT-800 N EMB- 800T ACOPEL F /180 N DEF.ASP.TGT/THGT-800 (impeller side) DEF.DES.TGT/THGT-800 (motor side) 900 ARO BRIDA TGT/THGT-900 N EMB- 900T ACOPEL F /180 N DEF.ASP.TGT/THGT-900 (impeller side) DEF.DES.TGT/THGT-900 (motor side) 1000 ARO BRIDA TGT/THGT-1000 N EMB- 1000T ACOPEL F /180 N DEF.ASP.TGT/THGT-1000 (impeller side) DEF.DES.TGT/THGT-1000 (motor side) 1250 ARO BRIDA TGT/THGT-1250 N EMB- 1250T ACOPEL F /200 N DEF.ASP.TGT/THGT-1250 (impeller side) DEF.DES.TGT/THGT-1250 (motor side) Support feet (Horizontal) Support feet (Vertical) Back draft shutter* Back draft shutter Circular sound attenuator Flexible connector ATEX 400 PIE SOP.TGT/THGT-400 PIE SOP.TGT/THGT-400 V CLAR-400 SIL CZ 400 SIL CZO 400 ACOPEL EX 400/ 160 N 450 PIE SOP.TGT/THGT-450 PIE SOP.TGT/THGT-450 V CLAR-450 SIL CZ 450 SIL CZO 450 ACOPEL EX 450/ 160 N 500 PIE SOP.TGT/THGT-500 PIE SOP.TGT/THGT-500 V CLAR-500 SIL CZ 500 SIL CZO 500 ACOPEL EX 500/ 160 N 560 PIE SOP.TGT/THGT-560 PIE SOP.TGT/THGT-560 V CLAR 560 SIL CZ 560 SIL CZO 560 ACOPEL EX 560/ 160 N 630 PIE SOP.TGT/THGT-630 PIE SOP.TGT/THGT-630 V CLAR 630 SIL CZ 630 SIL CZO 630 ACOPEL EX 630/ 160 N 710 PIE SOP.TGT/THGT-710 PIE SOP.TGT/THGT-710 V CLAR 710 SIL CZ 710 SIL CZO 710 ACOPEL EX 710/ 180 N 800 PIE SOP.TGT/THGT-800 PIE SOP.TGT/THGT-800 V CLAR 800 SIL CZ 800 SIL CZO 800 ACOPEL EX 800/ 180 N 900 PIE SOP.TGT/THGT-900 PIE SOP.TGT/THGT -900 V CLAR 900 SIL CZ 900 SIL CZO 900 ACOPEL EX 900/ 180 N 1000 PIE SOP.TGT/THGT-1000 PIE SOP.TGT/THGT-1000 V CLAR 1000 SIL CZ 1000 SIL CZO 1000 ACOPEL EX 1000/ 180 N 1250 PIE SOP.TGT/THGT-1250 PIE SOP.TGT/THGT-1250 V CLAR 1250 SIL CZ 1250 SIL CZO 1250 ACOPEL EX 1250/ 200 N Antivibration mounts (AM) Divide the total weight of the fan by 4, as you need 4 antivibration mounts per unit, and then look for the appropriate model according to their load. (See: Mounting accessories) See complete information on the Mounting Accesories. * Only horizontal mounting.

11 Installation of the mounting accessories OUTLET INLET Outlet grille Inlet grille air-stream direction Flexible flange connector Flexible flange connector Ducting Matching flange Support feet Matching flange Ducting Back draft shutter Inlet adapter protection guard See complete information on the Mounting Accesories. Fitting anti-vibration mounts in the short models When fitting anti-vibration mountings, short models, it is recommended they are fitted to a suitable support frame (not supplied by S&P) following the minimum distances as specified in the table. TGT L min. R min. Total L min. R min. PERFORMANCE CURVES The performance curves are available on: Soler & Palau WEBSITE. EASYVENT Fan Selection Programme.

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped

More information

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

COMPACT Series type HCFB / HCFT (Plastic impellers)

COMPACT Series type HCFB / HCFT (Plastic impellers) Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS ATEX LOG ASE AXAL FLOW FA ALATO ATEX ucted Axial Flow Fans suitable to exhaust/supply air in presence of chemical processes, water and sewage treatment, material and gas waste, dust and paint extraction,

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made

More information

"LCA"- long cased axial fan

LCA- long cased axial fan "LCA"- long cased axial fan Long cased axial fans for industrial/commercial use Thirteen sizes - from 310mm to 1250mm diameter Airflow from 2,200 to 80,000m 3 /hr Single or Three Phase 2, 4 or 6 pole motors

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

BIFURCATED AXIAL FANS

BIFURCATED AXIAL FANS BFURATE AXAL FAS SB (YL) ALATO SB (O) Bifurcated axial fans suitable to move air in hostile applications, for example in case of dust and chemical substances in heavy industrial, boiler houses, corrosive

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

NOVENCO FAN CATALOGUE

NOVENCO FAN CATALOGUE NOVENCO FAN CATALOGUE WWW.NOVENCO-MARINE.COM ZERAX AXIAL FLOW FANS PRODUCT The Novenco ZerAx series of axial flow fans use innovative design to reduce power consumption and to better fan efficiency. The

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

BIFLOW SB CON Product Brochure

BIFLOW SB CON Product Brochure BIFLOW SB CON Brochure Available for next day delivery with ELTA SELECT Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification HCH/ATEX HCT/ATEX HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification Circular axial fans (HCH) or Long-cased fans (HCT) with

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

AND AXIAL FLOW FANS ECOFIT

AND AXIAL FLOW FANS ECOFIT AND AXIAL FLOW FANS with adjustable blades as standard fans, explosion proof design and smoke fans ECOFIT Rosenberg East Asia Pte Ltd 71 Ubi Crescent #08-04 Excalibur Centre Singapore 408571 Tel: +65 6846

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

JM Aerofoil Bifurcated Fans

JM Aerofoil Bifurcated Fans JM Aerofoil Bifurcated Fans JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. HCH HCH Extremely robust wall-mounted, axial or tubular fans Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. Fan: Airflow direction from

More information

CASED 24 Designed for emergency ventilation of hot fire smoke applications 300 C or 400 C for two hours operation, CE marked to EN12101-3 2002 All casings are hot dipped galvanised Sizes from 315mm to

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices Aerofoil Ventilation Fans Quality & Performance at Affordable Prices GENERAL FEATURES, located in Chennai strives to deliver quality products at affordable costs to all its customers. Our company s vision

More information

CVHT Series - F rated cabinet fans

CVHT Series - F rated cabinet fans N 50-55 1/1/08 19:26 Página 50 BLT DRIVN BINT NS Series - 00 120 rated cabinet fans NW pproved to N12101- standard Range of belt drive cabinet fans designed for smoke extraction in fire conditions and

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information