AIR HANDLING UNITS YSE
|
|
- Corey Nicholson
- 5 years ago
- Views:
Transcription
1 IR DIG UITS YSE
2 YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to provide heating in winters using hot water and cooling in summers using chilled water. There are altogether 18 horizontal unit models and 18 vertical unit models. The units can meet a number of external pressure requirements, with options such as evaporative humidifier. They support both direct air return and ducted air return, as well as top air outlet and front air outlet. eatures of YSE Series ir andling Units Elegant Design ll panels are made of high quality galvanized steel to ensure a smooth surface and attractive profile. Stability ll internal components of the air handling units are firmly placed inside the high-strength frame. igh eat Exchange Efficiency The high quality coil of the YSE unit is made of expanded copper tubes and rippled aluminum fins, with high efficiency heat exchange. Equipped with a high air flow fan, the unit can reach maximum efficiency for heat transfer. Quiet Operation The unit uses a low noise belt driven motor for quiet operation. The fan, which is the latest low speed and high volume model, emits very little noise. Dry Pan The dry pan allows quick and easy drainage of condensation. lexible and ow cost Installation The internal structure has been designed using computer-aided design software, giving the units a small installation footprint. This allows the unit to be installed within a limited space and ensures the installation cost is kept to a minimum. Each unit provides two installation options - duct type and non-duct type, together with two air outlet configurations - top outlet or front outlet for better space usage. Easy lean ilter The filter in the duct type YSE air handling units comprises nylon plate pre-filters which can be pulled out easily from the left or the right and is convenient to clean. Options 1- or 2-Row oil Evaporative umidifier TiO2 Sterilizer ir Supply onfiguration orizontal Unit Vertical Unit omenclature YSE 04 D 4 X T D odel ame Design Series umber 2 On the cover Integrated professional services designed for your unique business need. We care about your business and understand that each business has its unique requir all-encompassing maintenance package is tailor-made to fit your every financial and tec It covers from planned routine equipment inspections and predictive maintenance routines to system performance checks and annual shutdowns. ominal irflow: odel ode x 10 3 m 3 /h Structure: - orizontal Type; V- Vertical Type D- Double Unit; S- Single Unit ooling oils: 4-4-Row oil 6-6-Row oil Split oils, ooling and oil 41S- 4-Row ooling + 1-Row 42S- 4-Row ooling + 2-Row 61S- 6-Row ooling + 1 Row 62S- 6-Row ooling + 2-Row ooling oil ollowed with Evaporative umidifier 43-4-Row ooling + 50mm Evaporative umidifier 44-4-Row ooling + 100mm Evaporative umidifier 45-4-Row ooling + 150mm Evaporative umidifier 46-4-Row ooling + 200mm Evaporative umidifier 63-6-Row ooling + 50mm Evaporative umidifier 64-6-Row ooling + 100mm Evaporative umidifier 65-6-Row ooling + 150mm Evaporative umidifier 66-6-Row ooling + 200mm Evaporative umidifier Power Supply : 380~415V-3Ph-50z D: 460V-3Ph-60z E: 380V-3Ph-60z : 230V-3Ph-60z one:380v-3ph-50z T- With TiO2 Sterilizer; 0- Without TiO2 Sterilizer ir supply method:, B,, D X- resh ir ondition; 0- Return ir ondition onnection: - eft and Side; R- Right and Side ote: acing the return air intake, it is the right hand if water pipes are on the right side of unit; vice versa. 3
3 Specifications Specifications orizontal Unit Vertical Unit Return ir ondition resh ir ondition Dimension mm Weight kg oil Inlet/Outlet Return ir ondition resh ir ondition Dimension mm Weight kg oil Inlet/Outlet odel irflow (m 3 /h) Rows ooling ooling External Total Pa otor Power W Single Double Return ir ondition resh ir ondition Drainage odel irflow (m3/h) Rows ooling ooling External Total Pa otor Power W Single Double Return ir ondition resh ir ondition Drainage YSE02S/D Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") YSE02VS/VD Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") YSE03S/D Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") YSE03VS/VD Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") YSE04S/D Ø48(1-1/2") Ø48(1-1/2") Ø60(2") Ø60(2") YSE04VS/VD Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") Ø48(1-1/2") YSE05S/D Ø48(1-1/2") Ø48(1-1/2") Ø60(2") Ø60(2") YSE05VS/VD Ø48(1-1/2") Ø48(1-1/2") Ø60(2") Ø60(2") YSE06S/D Ø60(2") Ø60(2") Ø60(2") Ø60(2") YSE06VS/VD Ø48(1-1/2") Ø48(1-1/2") Ø60(2") Ø60(2") YSE07S/D Ø60(2") Ø60(2") Ø60(2") Ø60(2") YSE07VS/VD Ø60(2") Ø60(2") Ø60(2") Ø60(2") YSE08S/D 8000 YSE10S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE08VS/VD 8000 YSE10VS/VD Ø60(2") Ø60(2") Ø76(2-1/2") Ø76(2-1/2") Ø60(2") Ø60(2") Ø76(2-1/2") Ø76(2-1/2") (1-1/4") YSE12S/D YSE15S/D Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") (1-1/4") YSE12VS/VD YSE15VS/VD Ø60(2") Ø60(2") Ø76(2-1/2") Ø76(2-1/2") Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE18S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE18VS/VD Ø89(3") Ø89(3") Ø89(3") Ø89(3") YSE20S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE20VS/VD Ø89(3") Ø89(3") Ø89(3") Ø89(3") YSE22S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE22VS/VD Ø89(3") Ø89(3") Ø89(3") Ø89(3") YSE25S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") YSE25VS/VD Ø76(2-1/2") Ø76(2-1/2") Ø76(2-1/2") Ø76(2-1/2") YSE28S/D YSE30S/D YSE33S/D YSE36S/D Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") Ø76(2-1/2") Ø76(2-1/2") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") Ø89(3") ote: 1. Standard return air cooling conditions: air inlet at 27 DB/19.5 WB; chilled water inlet/outlet at 7 / Standard return air heating conditions: air inlet at 21 DB; hot water inlet/outlet at 60 / ooling conditions of fresh air unit: air inlet at 35 DB/28 WB; chilled water inlet/outlet at 7 / conditions of fresh air unit: air inlet at 7 DB; hot water inlet/outlet at 60 / igh efficiency, double air inlets forward curved fans are applied phase asynchronous motors with class IP54 insulation are applied. Power Supply: 380V-3Ph-50z, V-3Ph-50z, 460V-3Ph-60z, 380V-3Ph-60z or 230V-3Ph-60z. 7. If the unit has TiO2, evaporative humidifier or split coil (cooling+heating) option, the external total pressure will be reduced by the corresponding component's pressure drop. ote: 1. Standard return air cooling conditions: air inlet at 27 DB/19.5 WB; chilled water inlet/outlet at 7 / Standard return air heating conditions: air inlet at 21 DB; hot water inlet/outlet at 60 / ooling conditions of fresh air unit: air inlet at 35 DB/28 WB; chilled water inlet/outlet at 7 / conditions of fresh air unit: air inlet at 7 DB; hot water inlet/outlet at 60 / igh efficiency, double air inlets forward curved fans are applied phase asynchronous motors with class IP54 insulation are applied. Power Supply: 380V-3Ph-50z, V-3Ph-50z, 460V-3Ph-60z, 380V-3Ph-60z or 230V-3Ph-60z. 7. If the unit has TiO2, evaporative humidifier or split coil (cooling+heating) option, the external total pressure will be reduced by the corresponding component's pressure drop. 4 5
4 Options Industrial leading technology - ano-tio2 healthy air sterilizer (optional) Johnson ontrols is committed to providing comfortable and healthy living and working environment for all our customers. Whilst caring and safeguarding the natural environment outside. With indoor air quality becoming a crucial global health concern, our unique nano-tio2 healthy air sterilization technology, can help remove almost all airborne germs and pathogens, ensuring healthy and fresh indoor air supplies. By oxidising and decomposing the harmful substances in the air, YORK ano-tio2 healthy sterilization technology kills airborne germs, eliminates bad odors, and other harmful particles safely and efficiently. Biological pollutant - e.g. bacteria and germs olds, fungi Inorganic gaseous pollutant - e.g. Ox, SOx Smoke and offensive odours Organic pollutant - volatile organic compounds (VOs) e.g. formaldehyde, benzene ano-tio2 Disinfection Technology YORK ano-light UV- Emits UV waveband for optimal germ-killing efficiency armful substances & pathogen in the air Bacteria, Viruses old, ungi Ox, SOx Purified ir n environmentally safe and effective air purification solution When TiO2 is exposed to low-intensity ultraviolet rays (UV-), a reaction occurs which generates hydroxyl radicals ( O) and super-oxide ions (O2.-). ydroxyl radicals ( O) are very powerful oxidizing agents which quickly react to the carbon and hydrogen components of pollutants and decompose them into harmless carbon dioxide (O2) and water (2O). The YORK ano-tio2 photocatalytic process is highly efficient at generating free hydroxyl radicals ( O), which makes it highly effective in eliminating airborne pollutants such as microorganisms and volatileorganic compounds (VOS). * This system was tested by the following reputable institutes and organizations: igh efficiency in killing germs The ong Kong Polytechnic University, Report o. P The Productivity ouncil of ong Kong, Report o The Detection entre of icrobiology, Guangzhou, PR, Report o VOs Odors Dust ano-tio2 Disinfection Technology Disinfection & TVO removal efficiency over Bacteria level 6-8 hours TiO2 omponent Dimensions odel Dimensions W odel YSE02S/D YSE03S/D YSE04S/D YSE05S/D YSE06S/D YSE07S/D YSE08S/D YSE10S/D YSE12S/D YSE15S/D YSE18S/D YSE20S/D YSE22S/D YSE25S/D YSE28S/D YSE30S/D YSE33S/D YSE36S/D YSE02VS/VD YSE03VS/VD YSE04VS/VD YSE05VS/VD YSE06VS/VD YSE07VS/VD YSE08VS/VD YSE10VS/VD YSE12VS/VD YSE15VS/VD YSE18VS/VD YSE20VS/VD YSE22VS/VD YSE25VS/VD Dimensions W ano-tio2 healthy air sterilization technology contains the following features: YORK is the first brand in the industry to apply ano-grade TiO2 technology to fan coils, residential and commercial central air conditioners, and residential split units. ano-grade TiO2 has been recognised in 125 countries and is patent-pending TiO2 photo-catalysis not only filters bacteria but also kills them The ultraviolet light (UV) in ano-tio2 ealthy ir Sterilizer is designed to be durable, lasting up to 10,000 hours If the ano-grade TiO2 sterilizer is ordered by customers, it will be installed on the YSE unit by the manufacturer prior to shipping. The ultraviolet lamp which delivered with the unit together, be installed by user in the field. 6 7
5 Dimensions - orizontal Unit Dimensions Vertical Unit Supply ir ethod - Top outlet Supply ir ethod - Top Outlet B 40 O PXQ 80 E D 80 B 40 D E G E R J K Top View O J K P Q R Supply ir ethod - ront outlet Supply ir ethod - ront Outlet D E G E 80 E D 40 B O PXQ R J K Top View J K ote: The above applies to B-type air supply. The supply air outlet is on the right for -type air supply. ir flow ength eight Width S upply ir Outlet Dimensions ocation Dimensions Return ir Inlet Base oil mm(inch) odel J K B D E O P Q eight U m 3 /h Type B Type Type D Type 4 Rows 6 Rows 4 Rows 6 Rows R 4 Rows 6 Rows YSE02S/D Ø48(1-1/2") Ø48(1-1/2") YSE03S/D Ø48(1-1/2") Ø48(1-1/2") YSE04S/D Ø48(1-1/2") Ø60(2") YSE05S/D Ø48(1-1/2") Ø60(2") YSE06S/D Ø60(2") Ø60(2") YSE07S/D Ø60(2") Ø60(2") YSE08S/D Ø76(2-1/2") Ø89(3") YSE10S/D Ø76(2-1/2") Ø89(3") YSE12S/D Ø89(3") Ø89(3") YSE15S/D Ø89(3") Ø89(3") YSE18S/D Ø76(2-1/2") Ø89(3") YSE20S/D Ø76(2-1/2") Ø89(3") YSE22S/D Ø76(2-1/2") Ø89(3") YSE25S/D Ø76(2-1/2") Ø89(3") YSE28S/D Ø76(2-1/2") Ø89(3") YSE30S/D Ø76(2-1/2") Ø89(3") YSE33S/D Ø89(3") Ø89(3") YSE36S/D Ø89(3") Ø89(3") ength eight Width S upply ir Outlet Dimensions ocation Dimensions Return ir Inlet oil mm (inch) ir flow J K Base U odel 4 Rows 6 Rows 4 Rows 6 Rows B D E G B D eight 4 Rows 4 Rows 6 Rows 6 Rows at at at at at at at at O P Q m 3 /h Type Type Type Type Return resh Return resh Return resh Return resh R at at at at ir ir ir ir ir ir ir ir Reture ir resh ir Reture ir resh ir YSE02VS/VD Ø48(1-1/2") YSE03VS/VD Ø48(1-1/2") Ø60(2") YSE04VS/VD Ø48(1-1/2") Ø60(2") YSE05VS/VD Ø48(1-1/2") Ø60(2") YSE06VS/VD Ø48(1-1/2") Ø60(2") Ø76(2-1/2") YSE07VS/VD Ø60(2") Ø76(2-1/2") YSE08VS/VD Ø60(2") Ø76(2-1/2") YSE10VS/VD Ø60(2") Ø76(2-1/2") YSE12VS/VD Ø60(2") Ø76(2-1/2") Ø89(3" ) YSE15VS/VD Ø76(2-1/2") Ø89(3") YSE18VS/VD Ø89(3") YSE20VS/VD Ø89(3") YSE22VS/VD Ø89(3") YSE25VS/VD Ø76(2-1/2") Ø89(3") YSE28VS/VD Ø89(3") YSE30VS/VD Ø89(3") YSE33VS/VD Ø89(3") YSE36VS/VD Ø89(3") 8 8 9
6 PUB-7426(0614)
YSM Air Handling Units YSM
YSM Air Handling Units YSM On the cover Integrated professional services designed for your unique business need. 2 We care about your business and understand that each business has its unique requirements.
More informationair handling units YAH
air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or
More information42HS Fan Coil Unit (High Static Pressure)
42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More informationVITALITY Centrifugal Large Split
VITITY entrifugal arge Split V-VIR 20 to 90 complete range from 16.8 kw up to 87.3 kw Y2open eatures ew Y2open board igh efficiency R and P conomizer or motorized damper Indoor air quality ot water coil
More informationair handling units YAH
air handling units YAH C: 380 5V-3Ph-50Hz D: 0V-3Ph-0Hz E: 380V-3Ph-0Hz F: 30V-3Ph-0Hz None:380V-3Ph-50Hz 3 If the unit has TiO, evaporative humidifier or split coil (cooling+ing) option, the external
More informationSpace Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)
MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular
More informationwe make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.
we make clean air Air Filtration Solutions Industrial Commercial Residential Che mic al F ilte r HE PA Filt er Filter Although very effective against very fine particles, filters do not filter out gasses
More informationCarisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet
Carisma CRC Fan Coil Unit with Centrifugal Fan with synchronous Motor Range includes 9 air rates (from to 1500 m /h) and 5 models (for wall and ceiling installation, with casing and concealed), each equipped
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationNH 3. Evaporator. Ammonia Applications Tons MANP
NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationCS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)
CS3 Series 50/60z Modular Central Station Air andling Units Air Volume: 1000 to 56000 cfm (1700 to 90 m 3/hr) Products that perform...by people who care DUNAM-BUS CS3 Series Introduction For more than
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationINTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter
INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationMAH. Modular Air Handling Unit
MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationInstaller s Manual. PCO/UV N-Duct Model
Installer s Manual PCO/UV N-Duct Model FACTS ABOUT THE PCO/UV N-DUCT UNIT AirGorilla combines the power of two highly regarded contaminant fighting technologies - ultraviolet light and PCO (photocatalytic
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationAir for life Featuring: NASA Developed Technology
LUNA Air for life Featuring: NASA Developed Technology Owner s Manual Photocatalytic Oxidation Air Purification System. For Use with model: LNT2-6000 Made in the U.S.A. For your safety and to ensure proper
More informationChilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14
Chilled Water Fan Coil Unit VV Stepless FCU Model : HFCF02~HFCF Features and Benefits ew Features Variable irflow & ccurate Control fan coil unit features variable airflow in addition to accurate temperature
More informationHigh Static Fan Coil Units YDFC
Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit
More information(Thin) (Ultrathin) Suspended Air-handling Unit
(Thin) (Ultrathin) Suspended Air-handling Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationHEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL
UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...
More informationMidea Air Handling Unit
Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without
More informationAdvanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS
Advanced PCO System Installation Instructions & Consumer Information Section I. Important Installer Information The Dynamic Advanced Photo Catalytic Oxidation (PCO) System utilizes the latest developments
More informationDUNHAM-BUSH ecs3 Series
DUNAM-BUS ecs3 Series INTRODUCTION For more than 100 years, Dunham-Bush has focused on innovative product development. Today, we provide a full portfolio of VAC/R products from Coil Units to large centrifugal
More informationShenzhen Xiangnan High-Tech Purify Equipment Co., Ltd
0 Intro of SAF Dear Sir or Madam, This is SAF, we are manufacturer and distributor for air filters and air clean equipment since 2002, based on Shenzhen China. Our product include: pre-filter, medium bag
More informationULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE
Shown with ILS OPTION (Internal Bracket/Light Shield) Kit ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE Remote version shown Models: UMX-1224T/ UMX-1924T / UMX-12242T / UMX-19242T 24v Power Input with
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationYLCS Water-cooled or remote air-cooled screw compressor chiller Heat pump application
YS ater-cooled or remote air-cooled screw compressor chiller eat pump application ooling capacities from 342 k to 10 k vailable configurations that meet lass energy efficiency levels at urovent Standard
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available
More informationIt is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.
Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Inner groove copper ashable filter Quiet function Multi fan speed
More informationFor Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System
Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For Mini Split Units NOTE: Please take time to read the attached assembly instructions. All instructions and precautions
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More information50RHR/50RVR/50RDR HORIZONTAL, VERTICAL AND DOWNFLOW WATER SOURCE HEAT PUMPS
0-1 0/0V/0 IZ, VI WW W IZ 1 / 2 to I VI 3 / 4 to I WW 1 1 / 4 to I II II I opyright 2000 arrier orporation yracuse, ew York 13221 orm 0-1 eplaces: ew rinted in... 2-00 atalog o. 1-170 ate: upersedes: 0/0V/0
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More informationResidential range. When technology meets comfort
Residential range When technology meets comfort Index Inverter technology 4 Indoor air quality 6 Design and control 8 Matching tables 10 Super Daiseikai 11 Suzumi 12 GKHP Fixed speed indoor units 13 Multi-split
More informationLUNA Air for life. Featuring: NASA Developed Technology. Owner s Manual. Photocatalytic Oxidation Induct Air Purification System.
LUNA Air for life Featuring: NASA Developed Technology Owner s Manual Photocatalytic Oxidation Induct Air Purification System. For Use with models: LNIND14 LNIND9 Made in the U.S.A. For your safety and
More information42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application
42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationTechnical Sales Guide # 040 YDFC 0 1 Page 2
17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows
More informationFan Coil Units. Technical Data ECDEN FWL-DT/DF
Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................
More informationModel: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
U V - AIRE AIR PURIFYING S YSTEM Model: UV-16R/24 ITEMS INCLUDED IN KIT: 1-24Volt UV-Aire Ballast Assembly 1-Mounting Base 1-Ultraviolet Lamp 6-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Fiberglass
More informationAesthetically Attractive Indoor unit. Enhanced with various Indoor Air Quality Features. Negative Ion Generator (Standard)
MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular
More informationBRIZA 22 HYBRID HEATING & COOLING
BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe
More informationCassette 4 Ways FCU DC Service manual
Cassette Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL022 to CL02 English Two-pipe Four-way Cassette DC Fan Coil Unit 1. External Appearance... 2 2. Features... 2. Product lineup.... Accessories....
More informationCRYSTAL-AIRE. concealed commercial air cleaners
CRYSTAL-AIRE concealed commercial air cleaners CRYSTAL-AIRE A Customized CONCEPT IN Concealed AIR CLEANING. Using a variety of accessories, Crystal-Aire can be adapted to most building configurations and
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationT A A 120 S 4 D - 1 M
PRODUCT SPECIFICATIONS AIR HANDLERS TA T-CLASS SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 50 HZ Bulletin No. 490133 February 2013 Supersedes December 2010 180-240 Models 072-090-120-150 Models Noal
More informationMVAM2241T MVAM2801T MVAM3351T MVAM4001T MVAM4501T MVAM5041T MVAM5601T MVAM6151T. 2-pipe system Golden Fin 3-pipe system MVA_CS - MVA_C - MVA_CB
MV Multisplit reversible Heat Pumps Variable refrigerant flow system (VRF) ooling apacity from 12,1kW to 246kW Heating apacity from 14,0kW to 276kW For systems with 2 and 3 pipes OUTDOOR UNITS MVS MVM
More informationWARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
2 Please read the safety and installation instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Photo-catalytic Air Purifier. WARNING: FAILURE
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationAir Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes
Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range
More informationMidea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual
Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More informationAPCO Rack System. A unique solution for the elimination of viruses, bacteria and VOC s. and saving energy FRESH-AIRE UV
FRESH-AIRE UV APCO Rack System A unique solution for the elimination of viruses, bacteria and VOC s 81cm - 117cm - 152cm UV-C lamps available and saving energy With the APCO Rack System it is also possible
More informationProduct Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz
18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design
More informationGuide Specifications. General. Casing. Coil/Drain pan. Fan/Motor
Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13
More informationRKB. Heat recovery units from 100 to m 3 /h >50 %
12 Lmf Clima 216 FRRRO GROUP RKB eat recovery units from to 5.4 m 3 /h Sheet metal supporting frame and double shell curtain panels externally pre-painted, fully removable with 2 mm thick internal thermal
More informationBUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC
BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,
More informationWater cooled condensers. Shell and tube condensers for fresh and sea water applications
Water cooled condensers Shell and tube condensers for fresh and sea water applications Water cooled condensers 4 5 6 7 8 9 10 11 12 13 14-15 16 17 18 19 20 21 22 23 The widest range world of applications
More informationINDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3
More informationFCC DUCTABLE AIR TREATMENT UNIT
FCC DUCTBLE IR TRETMENT UNIT DUCTBLE IR TRETMENT UNIT FCC 7 different sizes 3, 4 and 6 row coils 2 or 4 pipe system Horizontal installation ductable air treatment unit FCC series The ductable air treatment
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Ultraviolet Single and Dual Germicidal Lamps 60 Hz Part Numbers: P103-UVLTT1LP1020A01, P103-UVLTT1LP3020A01, P103-UVLTT2LP1020A01, P103-UVLTT2LP3020A01 SAFETY CONSIDERATIONS Installation
More informationADDITIVES & SYSTEM CLEANER made in germany. creating. technical. fluids.
ADDITIVES & SYSTEM CLEANER made in germany creating. technical. fluids. GAT premium brands. oil system. l Engine Purifier l Engine Care & Protect l CeraGAT 500 petrol system. l Petrol System Clean & Protect
More informationOWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER
OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT READ AND
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationDCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h
D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationPull handles, tubular handles, recessed handles
, tubular handles, recessed handles 303 K0187 170 R25 55 14 M8 35 R12 140 32 82 R8 14 M8 57 uroplast PF 31, black. ushing brass or galvanized steel. igh-gloss polished. K0187.101 25 ssembly: From the rear.
More informationHitachi Multizone Heat Pump Air Conditioning
Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in
More informationRefrigeration copper tube aluminum fin evaporator
Hangzhou Ponray Technologies Co., Ltd Add: Rm1903,Keda Touzi Bldg, No.555,Xincheng Rd,Binjiang,Hangzhou,China Tel: 0086-571-86433485 Fax:0086-571-86433481 P.I.C.: Richard Zeng Web: www.fridgtec.com E-mail:
More informationNEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only
NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page
More informationAnd ASEAN EAW WATER) Head. Office : Ruko
The Winner of INDONESIA ENERGY AWARD 2013 And ASEAN ENERGY AWARD 2004 2012 AIR HANDLING UNIT (AHU CHILLED WATER) 1.600 M³/ /hr. 52.000 M³/hr EAW CHILLED WATER PT. METROPOLITAN BAYU INDUSTRI A member of
More information5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en)
5/S v. (en) NZ, NZR, NZP, NS, NSR, NSP, NES, NEZ www.klimaoprema.hr www.klimaoprema.hr 7 TAE CNTENTS Types and sizes... 9 Conventional wall s... Conventional ceiling s... Economic s... Accessories... Construction
More informationFCVC Series VERTICAL FAN COILS
VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,
More informationFULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationControl of gaseous emissions and dust in a single-step solution
Control of gaseous emissions and dust in a single-step solution CataFlex catalytic filter bags 2 Control of gaseous emissions along with dust and cut CAPEX - Significant reductions in CAPEX and OPEX compared
More informationPA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER PA55 10 SEER C 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationComplete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE
Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE Air Handler Base Models: 92-052, 92-053, 92-054 (small) 24VAC- 92-055, 92-056, 92-057 Models: 92-046, 92-047, 92-048
More informationDSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient
DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...
More information