It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.

Size: px
Start display at page:

Download "It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use."

Transcription

1 Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Inner groove copper ashable filter Quiet function Multi fan speed Compact design Flexible air inlet/outlet directions, meet different installation requirements. ashable filter is optional when equiped with air return box. Item DB ( ) B ( ) Inlet ( ) Outlet ( ) Cooling Heating 21 2 Rows/Standard FP-34A-K FP-51A-K FP-68A-K FP-85A-K FP-12A-K FP-136A-K FP-17A-K FP-24A-K 2/146/125 3/232/155 4/291/194 /375/2 /464/39 8/644/429 1/7/ 12/926/ Cooling/Heating k 1.9/ / / /7. 5.5/ / / / ater flow volume l/s k Ft G ( D H) ckage /17 15/ /21 18/22 19/ /35 34/39 35/4 (outer groove) 448/ / / /355 22/247 22/247 22/247 Optionals Plenum with filter 2 Rows/High HF31 HF32 HF33 HF34 HF34 HF36 HF36 HF36 HF41 HF42 HF43 HF44 HF44 HF46 HF46 HF46 FP-34AH-K FP-51AH-K FP-68AH-K FP-85AH-K FP-12AH-K FP-136AH-K FP-17AH-K FP-24AH-K 2/146/125 3/232/155 4/291/194 /375/2 /464/39 8/644/429 1/7/ 12/926/ Cooling/Heating k 1.9/ / / /7. 5.5/ / / / ater flow volume l/s k Ft G ( D H) ckage /17 15/ /21 18/22 19/ /35 34/39 35/4 Connection pipe (inner groove) (outer groove) 448/49 447/ / / /355 22/247 22/247 22/247 Optionals Plenum with filter HF31 HF32 HF33 HF34 HF34 HF36 HF36 HF36 HF41 HF42 HF43 HF44 HF44 HF46 HF46 HF46

2 3 Rows Cooling/Heating 2/146/125 3/232/155 4/291/194 /375/2 /464/39 8/644/ k 2.19/ / / / / / ater flow volume l/s k Ft G Dimension ( D H) Outline ckage FP-34AS-R FP-51AS-R FP-68AS-R FP-85AS-R FP-12AS-R FP-136AS-R /19 16/2.5 18/ / /26 3/35 (inner groove) Connection pipe Condensed water drain diameter (outer groove) 448/49 392/ / / /31 22/247 Optionals Plenum with filter HF31 HF32 HF33 HF34 HF35 HF36 HF41 HF42 HF43 HF44 HF45 HF46 Cooling/Heating k ater flow volume l/s k Ft G ( D H) ckage (outer groove) Optionals Plenum with filter FP-17AS-R FP-24AS-R FP-238AS-R FP-272AS-R FP-36AS-R FP-34AS-R 1/7/ 12/926/618 14/971/729 1/1235/868 18/16/674 2/14/ / / / / / / / / /55 48/55 52/ 52/ 196/22 196/22 14/166 14/166 13/153 13/153 HF37 HF37 HF28 HF28 HF29 HF29 HF47 HF47 HF48 HF48 HF49 HF49 Item DB ( ) B ( ) Inlet ( ) Outlet ( ) Cooling Heating 21 4 Rows FP-34AF-R FP-51AF-R FP-68AF-R FP-85AF-R FP-12AF-R FP-136AF-R /8 289/259/ /324/27 477/368/ /7/395 7/616/ Cooling/Heating k 2.11/ / / / / / ater flow volume l/s k Ft G Dimension ( D H) Outline ckage / / / / / /4.5 (outer groove) 448/49 392/ / / /31 22/247 Optionals Plenum with filter HF31 HF32 HF33 HF34 HF35 HF36 HF41 HF42 HF43 HF44 HF45 HF46

3 4 Rows Cooling/Heating ater flow volume k l/s k Ft G ( D H) ckage (outer groove) Optionals Plenum with filter FP-17AF-R FP-24AF-R FP-238AF-R FP-272AF-R FP-36AF-R FP-34AF-R 948/7/ 143/926/618 14/971/729 1/1235/868 18/16/674 2/14/ / / / / / / / /44 52/ 52/ 59/66 59/66 3/4(19.5) 3/4(19.5) 196/22 196/22 14/166 14/166 13/153 13/153 HF37 HF37 HF28 HF28 HF29 HF29 HF47 HF47 HF48 HF48 HF49 HF Rows FP-34AT-R FP-51AT-R FP-68AT-R FP-85AT-R FP-12AT-R FP-136AT-R 188/156/8 289/259/ /324/27 477/368/ /7/395 7/616/ Cooling/Heating k 1.95/ / / / / / ater flow volume l/s k Ft G ( D H) ckage / / / / / /4.5 Connection pipe (inner groove) (outer groove) 448/49 392/ / / /31 22/247 Optionals Plenum with filter HF31 HF32 HF33 HF34 HF35 HF36 HF41 HF42 HF43 HF44 HF45 HF46 Dimension ( D H) Cooling/Heating ater flow volume Outline ckage (inner groove) Connection pipe Condensed water drain diameter (outer groove) Optionals Plenum with filter k l/s k Ft G FP-17AT-R FP-24AT-R FP-238AT-R FP-272AT-R FP-36AT-R FP-34AT-R 948/836/ /786/754 14/97/729 1/1235/867 18/16/674 2/14/ / / / / / / / /44 52/ 52/ 59/66 59/66 196/22 196/22 14/166 14/166 13/153 13/153 HF37 HF37 HF28 HF28 HF29 HF29 HF47 HF47 HF48 HF48 HF49 HF49

4 Caste Classical panel New panel Inner groove copper Built-in drain pump ashable filter Anti-cold Quiet function Multi fan speed Compact design function Self-diagnosis Four directions airflow that makes an even temperature and humidity distribution. Evaporator moisture auto cleaning after power off to avoid mildew. Forced high speed fan operation under emergency condition. Item DB ( ) B ( ) Inlet ( ) Outlet ( ) Cooling Heating 2 4 Cooling/Heating Power system ater system ater flow volume Body ( D H) ckage nel ( D H) ckage Connection pipe size Condensed water drain Standard controller ireless Optional controller ired FP-85XD/B-T FP-12XD/B-T FP-125XD/B-T FP-14XD/B-T FP-1XD/B-T FP-18XD/B-T FP-2XD/B-T 471/382/324 /559/ /588/ /735/ /824/ /853/ /1/853 k 4./5. 5./6. 6./7.8 8./9. 8.7/1. 9./ / l/s k Ft G /35 27/35 27/35 33/42 33/42 33/42 33/ /11 7/11 7/11 7/11 7/11 7/11 7/ / / / /12 112/12 112/12 112/12

5 Floor Ceiling Inner groove copper ashable filter Anti-cold function Quiet function Auto clean Multi fan speed Self-diagnosis Compact design The fan will be operated only if the chilled water inlet temperature is lower than the ting value to avoid warm air under cooling condition. Item DB ( ) B ( ) Inlet ( ) Outlet ( ) Cooling Heating 21 7 Air flow volume (H/M/L) Cooling Heating FP-34ZD-K FP-51ZD-K FP-68ZD-K FP-85ZD-K FP-12ZD-K FP-136ZD-K FP-17ZD-K FP-24ZD-K m /h 4/292/2 51/395/264 63/4/43 72/615/41 1/765/51 11/88/5 18/1276/8 24/1575/ /172/147 3/232/ /265/ /362/ /4/3 647/518/ /751/ 121/927/619 k k /23/ 1/23/ 1/23/ 1/23/ 1/23/ 1/23/ 1/23/ 1/23/ ater flow volume l/s Connection pipe ( D H) ckage Standard ireless remote controller k Ft G /33 26/33 27/34 27/34 34/4 34/4 48.5/ /57 224/ / /267 22/267 22/244 22/ / /117 φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) φ3/5(15.24) Optional

6 all Mounted Inner groove copper ashable filter Anti-cold function Quiet function Auto clean Multi fan speed Compact design Reasonable airflow that makes an even temperature and humidity distribution. Item DB ( ) B ( ) Inlet ( ) Outlet ( ) Cooling Heating 21 ithout air release valve FP-34BA2/A-K FP-51BA2/A-K FP-51BA2/A-K FP-68BA2/A-K FP-85BA2/A-K FP-85BA2/A-K Air flow volume High Medium Low Cooling k Heating k ater flow volume l/s k Ft G Connection pipe size Condensing water drain ( D H) ckage /14 11/14 11/14 Loading 4'GP quantity 4'HQ Standard ireless remote controller Optional

7 ith air release valve Air flow volume High 212 Medium Low Cooling k Heating k ater flow volume l/s k Ft G Connection pipe ( D H) ckage Standard ireless remote controller Optional FP-34BA2/D-K φ5/8() 845X18X X255X355 11/14 765/8 (XFAN) FP-51BA2/D-K φ5/8() 845X18X X255X355 11/14 765/8 (XFAN) FP-68BA2/D-K 4/348/ / φ5/8() 94X2X298 11X285X38 595/671 (XFAN) FP-85BA2/D-K φ5/8() 94X2X298 11X285X38 595/671 (XFAN)

CEILING CONCEALED SPLIT SYSTEM C SERIES

CEILING CONCEALED SPLIT SYSTEM C SERIES CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.

More information

air handling units YAH

air handling units YAH air handling units YAH C: 380 5V-3Ph-50Hz D: 0V-3Ph-0Hz E: 380V-3Ph-0Hz F: 30V-3Ph-0Hz None:380V-3Ph-50Hz 3 If the unit has TiO, evaporative humidifier or split coil (cooling+ing) option, the external

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Chilled Water Vertical Fan Coils

Chilled Water Vertical Fan Coils PRODUCT MANUAL Chilled Water Vertical Fan Coils Models: FWMW-C FWMW-H FWCW-C FWCW-H INDEX Vertical Fan Coil page 2 General Characteristics page 3 Technical data page 7 Sound Level page 9 Operating Limits

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

Chilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14

Chilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14 Chilled Water Fan Coil Unit VV Stepless FCU Model : HFCF02~HFCF Features and Benefits ew Features Variable irflow & ccurate Control fan coil unit features variable airflow in addition to accurate temperature

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001 42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000

More information

Fan Coil Unit Product Catalogue

Fan Coil Unit Product Catalogue AP-FCU-1 Chilled ater PRODUCT SYSTM all Mounted Cassette Ducted Fan Coil Unit Product Catalogue Products manufactured in an ISO certified facility. This document contains the most current product information

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

TECHNICAL MENUAL AIR HANDLING UNIT SCOPE

TECHNICAL MENUAL AIR HANDLING UNIT SCOPE TECHNICAL MENUAL AIR HANDLING UNIT SCOPE This course is intended to support engineering staff that are installing, commissioning, servicing or maintaining of our Air Handling Unit. Table of Contents 1

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES Donguan street, Shangyu City, Zhejiang Prov,China Tel:+86-575-82566722 Mobile:+86-13867501690 www.syfreezer.com E-mail:ring@syfreezer.com Unit Coolers Efficient

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts This part list contains the service parts for the Eclipse 00, 00, and 800 systems. D series models began early 0 The models that are covered include: EH0 C & D EH0 C & D ECC00 ECC00 ECC800 Contents Head

More information

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet Carisma CRC Fan Coil Unit with Centrifugal Fan with synchronous Motor Range includes 9 air rates (from to 1500 m /h) and 5 models (for wall and ceiling installation, with casing and concealed), each equipped

More information

U-Match Air Conditioner Indoor Unit

U-Match Air Conditioner Indoor Unit Technical specification MQS-24060-CFC216A ED020N0130 Cooling kw 0.42 Heating kw 0.42 Cooling A 2 Heating A 2 Max. Overcurrent Protection A V 185/242 mm 2 xpcs 1.0 3 db (A) 58/56/53 db (A) 68/66/63 - R22

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Cassette 4 Ways FCU DC Service manual

Cassette 4 Ways FCU DC Service manual Cassette Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL022 to CL02 English Two-pipe Four-way Cassette DC Fan Coil Unit 1. External Appearance... 2 2. Features... 2. Product lineup.... Accessories....

More information

air handling units YAH

air handling units YAH air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or

More information

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free

More information

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES:

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES: GENERAL "---" indicates that the feature is not an option with this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose lights

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

VXI Closed circuit cooling towers

VXI Closed circuit cooling towers Closed circuit cooling towers Key benefits Reliable Quiet Compact characteristics Counter flow, centrifugal fan, forced draft Capacity range up to 2615 kw Maximum entering fluid temperature 82 C Typical

More information

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 11/2016 1 PLEXUS CATALOGUE 09/2016 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller MCX Series - One Compressor

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599 EN 599-604 AKOR-HR 14/1/08 13:01 Página 599 HIGH EFFICIENCY HEAT RECOVERY UNIT AKOR-HR NEW Heat Recovery unit with casing manufactured from expanded polypropylene. Outlet and inlet duct conectors Ø150.

More information

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11 AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal

More information

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not feasible to provide a large central system and run duct work

More information

Solar Powered Split Type Centrifugal Air Blower

Solar Powered Split Type Centrifugal Air Blower Solar Powered Split Type Centrifugal Air Blower 1 * Strengthen air circulation * Remove heat, moisture, dust & Deduct harmful mildews * Solar powered, environmental friendly * Once Pay, Benefit Long *

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

Swegon PACIFIC. Integrated climate beam

Swegon PACIFIC. Integrated climate beam Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,

More information

Masnory Drill. Power Tool Accessories

Masnory Drill. Power Tool Accessories DMD3YG840MC7030HB 3 70 30 DMD4YG840MC7030HB 4 70 30 DMD5YG840MC8545HB 5 85 45 DMD6YG840MC10050HB 6 100 50 DMD7YG840MC10050HB 7 100 50 DMD8YG840MC12070HB 8 120 70 DMD9YG840MC12070HB 9 120 70 DM0YG840MC12070HB

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

TECHNICAL MANUAL SOFFIO Ducted units

TECHNICAL MANUAL SOFFIO Ducted units TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)

Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential) MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular

More information

Carisma The Ultra Quiet Fan Coil

Carisma The Ultra Quiet Fan Coil Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES Article Text ARTICLE BEGINNING 1993 AIR CONDITIONING & HEAT A/C General Diagnostic Procedures Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

AXIAL FAN WITH EXTERNAL ROTOR MOTOR

AXIAL FAN WITH EXTERNAL ROTOR MOTOR XIL FN ITH EXTERNL ROTOR MOTOR 1. YF series axial fans are external rotor motors. These motors have characteristics of compact structure, convenient installation and high efficiency etc. 2. YF series external

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

FCC DUCTABLE AIR TREATMENT UNIT

FCC DUCTABLE AIR TREATMENT UNIT FCC DUCTBLE IR TRETMENT UNIT DUCTBLE IR TRETMENT UNIT FCC 7 different sizes 3, 4 and 6 row coils 2 or 4 pipe system Horizontal installation ductable air treatment unit FCC series The ductable air treatment

More information

Exhaust air diffuser HPKH + Plenum box ATTS

Exhaust air diffuser HPKH + Plenum box ATTS Exhaust air diffuser HPKH + Plenum box ATTS The HPKH is a quiet, ceiling-mounted exhaust air diffuser. The diffuser has an almost completely perforated diffuser plate. The slot height of the diffuser can

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

AIR HANDLING UNITS YSE

AIR HANDLING UNITS YSE IR DIG UITS YSE YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to

More information

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4 Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

KWF Water Wash Canopy with Supply Air

KWF Water Wash Canopy with Supply Air KWF Water Wash Canopy with Supply Air SCHLIEREN THERMAL IMAGING SYSTEM Photographer: Matti Lehto The KWF is a highly effective kitchen ventilation canopy for the removal of contaminated air and excess

More information

AccuWash Automatic Temperature Control System

AccuWash Automatic Temperature Control System CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-64 Accuash Automatic Control System JOB AID Part No. 4322334 GOALS AND OBJECTIVES The goal of this Job Aid is to provide detailed information that

More information

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si Part 1 General Information.. 1 Part 2 Indoor Units. Part 3 Outdoor Units. Part 5 Control... Part 6 Control

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NEW. Wall controls. YFCN Fan Coil Units.     Technical Guide - for internal distribution only NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page

More information

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES GENERAL " - - - " indicates that the feature is not an option with this case model and/or that the data is not available at this time. LED lights only. Maximum of 5 rows of Standard LED Output lighted

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION Cooling system component layout 26-2-2 DESCRIPTION AND OPERATION 1 Heater matrix 2 Heater return hose 3 Heater inlet hose 4 Heater inlet pipe 5 Throttle housing 6 Connecting hose 7 Throttle housing inlet

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

Solutions from SPTT-3

Solutions from SPTT-3 Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static

More information

Part Ⅰ : Technical Information

Part Ⅰ : Technical Information Service Manual Part Ⅰ : 1. Summary Outdoor Unit GWHD(18)NK3JO(DRED) GWHD(24)NK3JO(DRED) GWHD(28)NK3JO(DRED) 1 2. Specifications Model GWHD(18)NK3JO(DRED) Product Code CB228W05900 Rated Voltage V~ 220-240

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information