TECHNICAL MENUAL AIR HANDLING UNIT SCOPE

Size: px
Start display at page:

Download "TECHNICAL MENUAL AIR HANDLING UNIT SCOPE"

Transcription

1 TECHNICAL MENUAL AIR HANDLING UNIT SCOPE This course is intended to support engineering staff that are installing, commissioning, servicing or maintaining of our Air Handling Unit.

2 Table of Contents 1 Compact Air Handling Unit Baisc Parameter Unit Under Ceiling Unit Vertical Unit Horizontal Unit Variable Performance Table Return Air Working Condition Fresh Air Working Condition Unit Dimensions Under Ceiling Unit Vertical Unit Horizontal Unit 16 2 Combined Air Handling Unit Typical Combination Type Economical Air Conditioner Comfortable Air Conditioner Craftwork Air Conditioner Filter Air conditioner Combination Type Air Conditioner Capability Table Dimensions of Unit 20 Request Parameter of Order 1

3 DE KON AIR HANDLING UNIT Denomination G - Direct:L Left type,r Right type Working Condition:Return air- neglect,fresh Air - X Coil Rows:4 rows -,6 rows - 6R Nominal Air Flow:Number 1000m 3 /h Type:Under Ceiling - DP;Vertical - LP;Horizontal - WP DEKON Air Handling Unit Notes: Unit direction judgment: Face to air inlet, inlet water pipe at left is left type, inlet water pipe at right is right type. 2

4 1. Compact Air Handling Unit 1.1 Basic Parameter Table Under Ceiling Unit Return Air Working Condition Performance Table Product Type GDP-02 GDP-03 GDP-04 GDP-05 GDP-06 GDP-08 GDP-10 GDP-12 GDP-15 Rated Air Volume m 3 /h Rated Cooling Capacity Rated Heating Capacity Flow L/s Cooled Water Resistance KPa External Static Pressure Pa Motor Power Noise Level db(a) Unit Weight R R R R R R R R R kg Dimension L W H mm Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. Rated Cooling capacity test working condition is:inlet air DB temperature 27,WB temperature19.5 Wateri inlet temperature 7,water temperature difference 5 ; Rated Heating capacity test working condition is: Inlet air DB temperature 21,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project. 3

5 Fresh Air Working Condition Performance Table Product Type Rated Air Volume m 3 /h Rated Cooling Capacity Rated Heating Capacity Flow L/s Cooled Water Resistance KPa External Static Pressure Pa Motor Power Noise Level db(a) Unit Weight kg Dimension L W H mm GDP-02 GDP-03 GDP-04 GDP-05 GDP-06 GDP-08 GDP-10 GDP-12 GDP-15 X RX X RX X RX X RX X RX X RX X RX X RX X RX Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. Rated Cooling capacity test working condition is:inlet air DB temperature 35,WB temperature28 Wateri inlet temperature 7,water temperature difference 5 ; Rated Heating capacity test working condition is: Inlet air DB temperature 7,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project. 4

6 1.1.2 Vertical Unit Return Air Working Condition Performance Table Product Type Rated Rated Rated Cooled Water External Air Cooling Heating Motor Noise Unit Static Volume Capacity Capacity Flow Resistance Power Level Weight pressure m 3 /h L/s KPa db(a) kg Pa GLP R GLP R GLP R GLP R GLP-06 6R GLP-08 GLP-10 GLP-12 GLP-15 GLP-18 GLP-20 GLP-24 GLP-30 GLP-35 GLP R R R R R R R R R R Dimension L W H mm

7 Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. Rated Cooling capacity test working condition is:inlet air DB temperature 27,WB temperature19.5 Wateri inlet temperature 7,water temperature difference 5 ; Rated Heating capacity test working condition is: Inlet air DB temperature 21,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project. Fresh Air Working Condition Performance Table Product Type Rated Rated Rated Cold water External Air Cooling Heating Motor Noise Unit Static Volume capacity capacity Flow Resistance Power Level Weight Pressure m 3 /h L/s KPa db(a) kg Pa GLP-02 X RX GLP-03 X RX GLP-04 X RX GLP-05 X RX GLP-06 X RX GLP-08 GLP-10 GLP-12 GLP-15 GLP-18 GLP-20 GLP-24 GLP-30 GLP-35 GLP-40 X RX RX X RX X RX X RX X RX X RX X RX X RX X RX Dimension L W H mm Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. Rated Cooling capacity test working condition is:inlet air DB temperature 35,WB temperature28 Wateri inlet temperature 7,water temperature difference 5 ; 6

8 Rated Heating capacity test working condition is: Inlet air DB temperature 7,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project Horizontal Unit Return Air Working Condition Performance Table Product Type Rated Rated Rated Cooled Water External Air Cooling Heating Motor Noise Unit Static Volume Capacity Capacity Flow Resistance Power Level Weight Pressure m 3 /h L/s KPa db(a) kg Pa GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R GWP R Dimension L W H mm Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. 7

9 Rated Cooling capacity test working condition is:inlet air DB temperature 27,WB temperature19.5 Wateri inlet temperature 7,water temperature difference 5 ; Rated Heating capacity test working condition is: Inlet air DB temperature 21,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project. Fresh Air Working Condition Performance Table Product type Rated Rated Rated Cooled Water External Air Cooling Heating Motor Noise Unit Static Volume Capacity Capacity Flow Resistance Power Level Weight Pressure m 3 L/s KPa /h db(a) kg Pa GWP-02 X RX GWP-03 X RX GWP-04 X RX GWP-05 X RX GWP-06 X RX GWP-08 X RX GWP-10 X RX GWP-12 X RX GWP-15 X RX GWP-18 X RX GWP-20 X RX GWP-24 X RX GWP-30 X RX GWP-35 X RX GWP-40 X RX Dimension L W H mm Remark: The value is the tested value in Cabinet type fan coil unit <JB/T > standard. Rated Cooling capacity test working condition is:inlet air DB temperature 35,WB temperature28 Wateri inlet temperature 7,water temperature difference 5 ; Rated Heating capacity test working condition is: Inlet air DB temperature 7,Inlet water temperature 60 If the real working condition is different with the above working condition, the user should select according to the project. 8

10 1.2 Variable Performance Table Return Air Working Condition Cooling Variable Performance Table Inlet Air Temp.( ) DB 24 / WB 17 DB 25 / WB 18 Inlet Water Temp.( ) Model Cooling Capacity R R R R R R R R R R R R R R R Inlet Air Temp.( ) DB 27 / WB 19.5 DB 28 / WB 21 Inlet Water Temp.( ) Model Cooling Capacity 9

11 R R R R R R R R R R R R R R R Inlet Air Temp.( ) DB 29 / WB 23 DB 30 / WB 26 Inlet Water Temp.( ) Model Cooling Capacity R R R

12 6R R R R R R R R R R R R Fresh Air Working Condition Cooling Variable Performance Table Inlet Air Temp.( ) DB 31 / WB 25 DB 32 / WB 26 Inlet Water Temp.( ) Model Cooling Capacity X RX X RX X RX X RX X RX X RX

13 X RX X RX X RX X RX X RX X RX X RX X RX X RX Inlet Air Temp.( ) DB 33 / WB 27 DB 35 / WB 28 Inlet Water Temp.( ) Model Cooling Capacity X RX X RX X RX X RX X RX X RX X RX X RX X RX X

14 6RX X RX X RX X RX X RX X RX Inlet Air Temp.( ) DB 36 / WB 29 DB 38 / WB 31 Inlet Water Temp.( ) Model Cooling Capacity X RX X RX X RX X RX X RX X RX X RX X RX X RX X RX X RX

15 X RX X RX X RX X RX Unit Dimensions Under Ceiling Unit Product Type L W H A B C 6R D D1 E F G J K M N GDP / GDP / GDP /

16 GDP GDP GDP GDP GDP GDP Vertical Unit Product Type L W H A B C 6R D D1 E F J K M N GLP / GLP / GLP / GLP / GLP / GLP / GLP / GLP / GLP / GLP

17 GLP GLP GLP GLP GLP Horizontal Unit 出风 出风 Product Type L W H A B C 6R D D1 E F G J K M N GWP / GWP / GWP / GWP / GWP / GWP / GWP / GWP / GWP / GWP GWP GWP GWP GWP GWP

18 2. Combined Air Handling Unit 17

19 2.1 Typical Combination Type Economical Air Conditioner Comfortable Air Conditioner Craftwork Air Conditioner 18

20 2.1.4 Filter Air Conditioner 2.2 Combination Type Air Conditioner Capability Table Cooling air return work condition:air inlet DB temperature 27,WB Temperature 19.5,water inlet temperature 7,water outlet temperature 12 4 rows 6 rows 8 rows Air Flow H=4 H=5.1 H=6 Volume m 3 /h Cooling Capacity Water Flow Kg/h Water Resistance kpa Cooling Capacity Water Flow Kg/h Water Resistance kpa Cooling Capacity Water Flow Kg/h Water Resistance kpa

21 Cooling fresh air work condition:air inlet DB temperature 35,WB Temperature 28,water inlet temperature 7,water outlet temperature 12 4 rows 6 rows 8 rows Air Flow H=8.1 H=10.3 H=12 Volume m 3 /h Cooling Capacity Water Flow Kg/h Water Resistance kpa Cooling Capacity Water Flow Kg/h Water Resistance kpa Cooling capacity Water Flow Kg/h Water Resistance kpa

22 2.3 Dimension of Unit Ⅰ.General Size Product type H B H1 ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK H B H1 Section Size of Combination Air Conditioner 21

23 Ⅱ.Fresh air mix segment, air outlet segment, air return segment, fresh air segment Product type L M N1 N2 ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK remark:1.air return door is N2 M,fresh air door N1 M 2.Horizontal air outlet door N2 M,up air outlet door N1 M M M 350 M N1 H H N2 250 B H1 B H1 L ZK-10~ZK-50 ZK-60~ZK

24 Ⅲ.Air return mix segment, air outlet segment, size drawing of air retrn segment, filter segment Product Type Name of Filter L Initial Resistance Pa Final Resistance Pa Filter Efficiency Remark ZK-10~ZK-160 Roughing Panel Type Filter Section % Not Include Connect Section ZK-10~ZK-160 Roughing/Medium Bag Type Air Filter Section % Including Connect Section ZK-10~ZK-160 Sub High Bag Type Filter Section % Including Connect Section ZK-10~ZK-160 High V Type Filter Section % Including Connect Section H1 H L L L Plate original filter segment(plate no spin cloth) Original filter/mid dle filter /sub high efficient bag filter segment High efficient V type filter segment 23

25 Ⅳ.Cooling Coil Product type 4 Rows 6 Rows 8 Rows DN1 DN2 DN1 DN2 DN1 DN2 ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK remark: 1) each set ZK-10~ZK-40 has one coil,and one water inlet pipe and one water outlet pipe. 2) ZK-50~ZK-100 has 2 coil,and two water inlet pipe and two water outlet pipe; 3) ZK-120~ZK-160 has 3 coil,and three water inlet pipe and three water outlet pipe 4) When the coil face wind velocity less then 2.5m/s,must install block water segment. DN1 H DN2 B H Size of Cooling Coil 24

26 Ⅴ.Fresh and Return Air Discharge Segment Product type L M N ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK M M 350 M N N H H B H1 B H1 L ZK-10~ZK-50 ZK-60~ZK-160 Size of Fresh and Return Air Discharge Segment 25

27 Ⅵ.Middle Filter Air Outlet Segment Product type L M N1 N2 ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK Remark: 1. Air outlet N1 M 2. Horizontal air outlet and up air outlet has the same size.(chose one of them)filter standard component is middle efficient no spin cloth bag filter. M M 350 M N1 N2 250 B B H1 H L ZK-10~ZK-50 ZK-60~ZK-160 Size of Middle Efficient Air Outlet 26

28 Ⅶ.Twice Air Return Segment Product type L M N ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK M M 350 M N H H B H1 B H1 L ZK-10~ZK-50 ZK-60~ZK-160 Size of Twice Air Return Segment 27

29 Ⅷ.Middle segment, block water segment, damp film block water segment, noise elimination segment, electrical heat segment Apellation of Segment Product Type L Instruction Middle segment ZK-10~ZK Airflow amortize,maintain block water segment ZK-10~ZK Pucker piece of galvanized armor plate damp film block water segment ZK-10~ZK Anti bacterium and mildew damp film board noise elimination segment ZK-10~ZK ZK-50~ZK Piece type muffler,noise elimination quantity 17dB electrical heat segment ZK-10~ZK Peristyle electrical heater L L L L L Middle segment, electrical heater, block water segment, damp film block water segment noise elimination segment Size of Middle Segment, Block Water Segment, Damp Film Block Water Segment, Noise Elimination Segment, Electrical Heater 28

30 Ⅸ.Steam Heater Segment (2 rows) Product Type DN1 mm DN2 mm Heat Exchange Surface m 2 Thermal Transmittance W/m 2.K ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK Remark:1.ZK-10~ZK-60 has 1 coil,and one water inlet and two water outlet pipe. 2. ZK-80~ZK-160 has 2 coil,and two water inlet and two water outlet pipe. DN1 H DN2 B H1 740 Size of Steam Heater Segment 29

31 Ⅹ.Humidifier Size of Humidifier Ⅺ.Sterilize Segment B H1 H 740 Size of Sterilize Segment 30

32 Ⅻ.Fan motor segment(blower segment, air return segment, fresh air segment, discharge segment) Product type L ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK H B H1 L Size of Fan Motor Segment 31

33 ⅩⅢ.Weight Table of Each Segment Second Roughing Medium Fresh Air Mixing Return Air Connect Sub High Product Type Return Air Efficiency Air Efficiency Air Section Section section Efficiency Filter Section Filter Filter ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK Rows 6 Rows 8 Rows Outlet Air Medium outlet Derust Fungus Evaporation Heating Product Type Cooling Cooling Cooling Section Air Section Section Section Section Section Section ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK

34 Electric Spray Section Spray Section Membrance Elimilator Exhaust Fan Product Type Heating of Single Stage of Single Stage Type Muffler Section Section Section Section Single Sow Two Row Elimilator ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK Dry Steam 50#Membrance 100#Membrance 150#Membrance Jet Type Electrode Product Type Fan Section Humidifier Type Humidifier Type Humidifier Type Humidifier Humidifier Humidifier Section ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK ZK

35 Request Parameter of Order Model No of combination air conditioner: Air flow: external pressure and static pressure: external colour of unit: Cooling capacity: Air return condition:db temp WB Temp or relative humidity: Fresh air condition:db temp WB Temp or relative humidity: Proportion of fresh air and return air or fresh air proportion: temp after mixed(db/ WB): Temp of inlet and outlet water: Azimuth of inlet and outlet water pipe ( face the wind outlet): left right) Heating quantity: Air return condition:db temp WB Temp or relative humidity: Air return condition:db temp WB Temp or relative humidity: Proportion of fresh air and return air: emp after mixed(db/ WB): Temp of water inlet: Temp of water outlet: Azimuth of inlet and outlet water pipe ( face the wind outlet): left right) Efficiency of filter: humidifier quantity: Installation type of filter: slideway frame type of humidifier: dry steam steam pressure: Suction azimuth of filter: side suction front suction high pressure spray damp film pole humidifier Power of electrical heater: grouping of electrical heater: Request of control: Function segment and other request Mix segment fan motor segment cooling coil segment equal flow segment heating coil air return(discharge) segment humidifier segment diffluence segment noise elimination segment discharge segment electrical heating segment middle efficient filter segment Special request: company: project kind:(purpose for building) Add: zip code: Phone: E -mail Fax: contact person: STAMP reserve the rights to modify the products but not inform customers, any doubts, please contact us. 34

Chiller assembly line Testing Lab. Painting line CNC machine

Chiller assembly line Testing Lab. Painting line CNC machine Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized in central air conditioning products. Its new industrial park covers a total

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

air handling units YAH

air handling units YAH air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or

More information

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Inner groove copper ashable filter Quiet function Multi fan speed

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES Donguan street, Shangyu City, Zhejiang Prov,China Tel:+86-575-82566722 Mobile:+86-13867501690 www.syfreezer.com E-mail:ring@syfreezer.com Unit Coolers Efficient

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

CornerAir. CornerAir. Active chilled beam

CornerAir. CornerAir. Active chilled beam Active chilled beam Description The active chilled beam is a one-way induction type air-conditioning unit that is designed for exposed installation, mounted directly under the ceiling against the corner.

More information

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X Date: 08.06.2018 Price: 13121 EUR without VAT, W Vilnius Air handling unit model: VERSO-CF-30-2.6-H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS COOLING CAPACITY FROM 6,7 TO 138 kw ED.X 331 U Kc 6 The range of close control units with remote condenser, series ED.X, is particularly indicated

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7 Calculation of external available Pressure Page 1 Size: 1 Air flow volume [m³/h] 4 6 8 1 12 14 16 18 2 24 28 32 36 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc. to white

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

induction Unit effective and efficient cooling, heating and ventilation

induction Unit effective and efficient   cooling, heating and ventilation effective and efficient cooling, heating and ventilation MiniB induction Units With MiniMal energy requirements, high output and low noise. induction Unit www.minib.com 2 about us ABOUT THE COMPANY MINIB

More information

induction Unit effective and efficient cooling, heating and ventilation

induction Unit effective and efficient   cooling, heating and ventilation effective and efficient cooling, heating and ventilation MiniB induction Units With MiniMal energy requirements, high output and low noise. induction Unit www.minib.com 2 about us ABOUT THE COMPANY MINIB

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

Ductable water unit FWD UNT-PRC002-E4

Ductable water unit FWD UNT-PRC002-E4 Ductable water unit FWD 08-1 - 0-0 - 4 UNT-PRC00-E4 Table of Contents General data... Performance data... 4 Cooling capacities... 4 Heating capacities... Water pressure losses... 6 Available static pressure...

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas! Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

McQuay MDM Air Handling Unit CMDM

McQuay MDM Air Handling Unit CMDM McQuay MDM Air Handling Unit CMDM - 2004 Contents Page Nomenclature System... 1 Features... 2 Performance Tables... 4 Outlines and Dimensions... 15 Section Weights... 23 Installation... 25 Operation...

More information

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

Air Handling Unit & Modular Air Handling Unit

Air Handling Unit & Modular Air Handling Unit 1703-7C1612 Commercial Air Conditioners 2017/2018 Quality Assurance ISO 9001 ISO 14001 Midea CAC After-service Application Environmental ManagementOHSAS 18001 Occupational Health and Safety Assessment

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

Broad multiplex outlet BF-V...

Broad multiplex outlet BF-V... Air distribution systems Broad multiplex outlet BF-V... DS 40 E 04.0 Technical Selection Preliminary remarks In many applications in the commercial sector, supply air is discharged via simple grilles built

More information

NV series. Induction VAV air volume control terminals

NV series. Induction VAV air volume control terminals NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...

More information

Vertical Floor Fan Coil Unit (Model FW)

Vertical Floor Fan Coil Unit (Model FW) Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

air handling units YAH

air handling units YAH air handling units YAH C: 380 5V-3Ph-50Hz D: 0V-3Ph-0Hz E: 380V-3Ph-0Hz F: 30V-3Ph-0Hz None:380V-3Ph-50Hz 3 If the unit has TiO, evaporative humidifier or split coil (cooling+ing) option, the external

More information

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser Halton TRB Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Supply air jet velocity is effectively reduced due to high mixing effect Installation

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

WCTA SERIES Air Handling Units. ( ,000 m 3 /h )

WCTA SERIES Air Handling Units. ( ,000 m 3 /h ) SERIES Air Handling Units ( 1800-115,000 m 3 /h ) 1 1 INDEX pag. 1 INTRODUCTION 4 1.1 Standard Units 4 1.2 Special Units 4 1.3 Size Choice / 1.4 Air Volumes 4-7 2 DIMENSIONAL DATA 7 2.1 Empty Sections

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement. Ceiling-mounted fan heaters TECHNICAL MANUAL GB INDEX 1 MAIN FEATURES... 2 2 RATED TECHNICAL DATA... 3 3 HEATING CAPACITIES... 4 3.1 Heating capacity with water operation... - 11 4 STEAM OPERATION... 12

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

SARAVEL MINI AIR-HANDLING UNIT

SARAVEL MINI AIR-HANDLING UNIT CAT-MAHU-2003(1) SARAVEL MINI AIR-HANDLING UNIT 800 TO 5500 CFM ( 1400 TO 9300 m³/hr ) 1 TABLE OF CONTENTS Introduction... 3 Specifications 4 Examples.... 5 Coil Circuiting & Physical Data..... 7 Rating

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

DC INVERTER VRF SYSTEMS C-VRF

DC INVERTER VRF SYSTEMS C-VRF DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound Halton TSR/TSS Swirl Diffuser Radial horizontal air supply Air velocity is effectively reduced due to high mixing effect Circular duct connection with gasket All sizes available as an adapted version for

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information