VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Size: px
Start display at page:

Download "VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X"

Transcription

1 Date: Price: EUR without VAT, W Vilnius Air handling unit model: VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other (Plate heat exchanger) AHU parameters RLT class A+ Supply Nominal flow rate [m³/h] / [m³/s] 3820 / 1,06 Nominal external pressure (ΔPs, ext) [Pa] 400 Exhaust Nominal flow rate [m³/h] / [m³/s] 3820 / 1,06 Nominal external pressure (ΔPs, ext) [Pa] 400 Int. pressure drop of ventilation components (ΔPs, int) [Pa] 695 Int. pressure drop of non-ventilation components (ΔPs, add) [Pa] 152 Design outdoor temprature winter [ C] -13 Face velocity at design flow rate [m/s] 1,49 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 1 / 7

2 SFPv [kw/m³/s] 2,46 Atmosphere pressure [Pa] Air density [kg/m³] 1,2 Full load I (3x400V) [A] 9,4 Effective electric power input [kw] 2,61 COMMISSION REGULATION (EU) No 1253 (ecodesign requirements) Value 2018 The thermal efficiency of HRS, Ƞt_nrvu (EN308) [%] Internal specific fan power, SFPint [W/m³/s] of drive - variable speed Installed Necessary Thermal by-pass facility Exist Necessary Warning - filter is clogged Exist Necessary Unit conformity assessment Complies Basic construction STANDART Panels from two galvanized steel sheets,filled with thermal and sound insulation fire-resistant min.wool (λ=0,036 W/mK). AHU painted C3 class, RAL Indoor unit. When filters gets dirty, unit control panel gives notice to change the filters. Dirty filters cause increased energy consumption, which decreases performance and energy efficiency of the unit, so it is very important to change the filters regularly. AHU shall operate with variable speed drive. /manuals/verso-manuals Verso manual version: V2-C Casing air leakage (Model Box, EN 1886) -400 Pa [dm³/(s m²)] 0, Pa [dm³/(s m²)] 0,09 Maximum external leakage rate at Pa [%] < 1 Maximum external leakage rate at Pa [%] < 1 Maximum internal leakage rate [%] < 1 AHU configuration Separate sections with base frame connected to each section Panels thickness [mm] 45 Unit weight Weight (netto) [kg] 705 Pallets VKA [mm] 750x1450(105kg) FVS [mm] 950x1450(118kg) UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 2 / 7

3 FVS [mm] 950x1450(118kg) PCF [mm] 1650x1450(363kg) Accessories Adjustable feet (RegKoj) Control automatics C5.1 ACOUSTIC DATA Sound power level Lw to the air ducts to surrounding Supply air volume [db] Exhaust air volume [db] [db] F[Hz] Inlet Outlet Inlet Outlet 63 63,7 73,1 64,5 71,5 67, ,4 59,2 57,7 69,7 71, ,0 79,7 70,1 75,9 72, ,7 77,4 64,5 71,9 53, ,0 70,1 50,9 73,3 52, ,6 72,4 47,5 69,4 45, ,7 68,6 46,7 66,6 36, ,7 61,1 39,1 60,5 29,7 db(a) Plate heat exchanger REK Atmosphere pressure [Pa] Plates Al Heat recovery class (EN13053) Efficiency bonus (E), (EU 1253) 393 H1 Winter Summer Supply Exhaust Supply Exhaust Temp. efficiency wet [%] 92,3 84,7 Temp. efficiency dry [%] 86,1 84,7 Power wet [kw] 37,4 11,3 Air volume [m³/h] Inlet temperature [ C] Relat. humidity [%] Outlet air temp. [ C] 17,5 0,5 23,5 30,4 Relat. humidity [%] 9,2 96,0 81,9 33,5 Pressure drop wet [Pa] Built-in loss [Pa] Velocity [m/s] 1,8 1,7 1,8 1,9 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 3 / 7

4 Condensation [l/h] -20,2 0,0 Attention, freeze danger! Droplet separator with drainage Pressure drop [Pa] 9 Single level deicing Actuator type Modulating (AC/DC 24V) Torque [Nm] 5 SUPPLY AIR VOLUME Damper with actuator Aluminium profile air damper Actuator type ON/OFF with spring return (AC/DC 24V) Torque [Nm] 4 Pressure drop [Pa] 2 Air filter Filter correction (F), (EU 1253) 0 Bag filter Energy efficiency class Air velocity class (EN13053) V1 Filter class F7 Dimensions bxhxl [mm] 490x490x500 Energy performance [kwh/a] 2287 Quantity of bags 6 Quantity of filters 2 Pressure drop (clean filter) [Pa] 68 Pressure drop [Pa] 109 Recomended max. pressure drop (EN ) [Pa] 150 Velocity in the AHU filter section [m/s] 1,49 Water air heater HW-G10-04R C-26F-M1-C40-IS1-XX-1 R¾/1 R¾ Capacity [kw] 25,4 Standard air volume [m³/h] 3820 Velocity [m/s] 1,91 Pressure drop [Pa] 52 Inlet temperature [ C] 0,2 Inlet rel. humidity [%] 9 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 4 / 7

5 Safety on surface [%] 0 Safety on capacity [%] 20 Outlet temperature [ C] 20,0 Outlet rel. humidity [%] 2 Absolute humidity [g/kg] 0,35 Fluid Water Inlet temperature [ C] 50 Outlet temperature [ C] 40 Flow rate [dm³/h] 2210 Pressure drop [kpa] 36,56 Etilenglycol by volume [%] 0 Technical specification Tubes Copper Plates Aluminium Volume [m³] 0,0057 Useful space [m²] 41,58 Fin pitch [mm] 2,6 Rows 4 Circuits 8 Connection in ["] 1 R¾ Connection out ["] 1 R¾ L [mm] 130 B [mm] 1200 H [mm] 560 Restrictions Max hidraulic pressure [bar] 15 Max fluid temperature [ C] 100 Impeller RH40C.CR Wheel diameter [mm] 400 Air volume [m³/h] 3820 Built-in loss [Pa] 23 Static pressure [Pa] 839 Total pressure [Pa] 868 Efficiency [%] 72,5 Shaft power [kw] 1,23 Shaft power (clean filters) [kw] 1,17 Speed [1/min] 2066 Max. speed [1/min] 3340 K-value 154 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 5 / 7

6 Motor PM Motor efficiency class IE5 (Ultra Premium) Motor power [kw] 2 Speed [1/min] 3160 Efficiency [%] 92.5 Rated current at 400V 50Hz [A] 4,6 FOP [Hz] 172 Frequency converter [kw] 2 Fan SFPv [kw/m³/s] 1,27 SFP class (EN ) SFP 3 Electric power to motor (Pm) [kw] 1,41 Electric power to motor (clean filters) [kw] 1,35 Electric power to motor class (EN13053) P1 Pm ref (EN13053) [kw] 1,97 Total fan efficiency [%] 65,09 Static fan efficiency [%] 62,93 Overall efficiency ErP [%] 66,63 HAUST AIR VOLUME Damper with actuator Aluminium profile air damper Actuator type ON/OFF with spring return (AC/DC 24V) Torque [Nm] 5 Pressure drop [Pa] 2 Air filter Filter correction (F), (EU 1253) 0 Bag filter Energy efficiency class Air velocity class (EN13053) V1 Filter class M5 Dimensions bxhxl [mm] 490x490x500 Energy performance [kwh/a] 1872 Quantity of bags 6 Quantity of filters 2 Pressure drop (clean filter) [Pa] 39 Pressure drop [Pa] 94 Recomended max. pressure drop (EN ) [Pa] 150 Velocity in the AHU filter section [m/s] 1,49 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 6 / 7

7 Impeller Designed for wet conditions RH40C.CR Wheel diameter [mm] 400 Air volume [m³/h] 3820 Built-in loss [Pa] 23 Static pressure [Pa] 808 Total pressure [Pa] 837 Efficiency [%] 72,8 Shaft power [kw] 1,18 Shaft power (clean filters) [kw] 1,1 Speed [1/min] 2035 Max. speed [1/min] 3340 K-value 154 Motor PM Motor efficiency class IE5 (Ultra Premium) Motor power [kw] 2 Speed [1/min] 3160 Efficiency [%] 92.5 Rated current at 400V 50Hz [A] 4,6 FOP [Hz] 170 Frequency converter [kw] 2 Fan SFPv [kw/m³/s] 1,19 SFP class (EN ) SFP 3 Electric power to motor (Pm) [kw] 1,36 Electric power to motor (clean filters) [kw] 1,27 Electric power to motor class (EN13053) P1 Pm ref (EN13053) [kw] 1,9 Total fan efficiency [%] 65,35 Static fan efficiency [%] 63,06 Overall efficiency ErP [%] 66,63 UAB Komfovent, Ozo g. 10, LT Vilnius, tel (5) , 7 / 7

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

CATCH THE OPPORTUNITIES OF NEW REGULATIONS

CATCH THE OPPORTUNITIES OF NEW REGULATIONS CATCH THE OPPORTUNITIES OF NEW REGULATIONS New European Regulation ErP NRVU Ecodesign Directive- Regulation 1253/2014 / CE ErP 2018 per unità di ventilazione non residenziali New European regulation on

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS HRE-TOP EC Non-residential ventilator unit ith dual flo and high

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

D1M L1 T2 TB DATA SHEET A1-1130H-1400W. PANELS / FRAME Panels PART CODE Insulation

D1M L1 T2 TB DATA SHEET A1-1130H-1400W. PANELS / FRAME Panels PART CODE Insulation 19/04/11 08/06/11 P 1 / 12 08A72185 Example 02 RDH 400 R - 1607-2. 08 FA DAMPER 930 x 30 mm 09 P40-16AC 1/2R-24T-30A-4.0Pa Cu/Al 11 G4+F7 12 HA10-30-060-2EOO-1-1-2-1250 x 1250 15 P40-16AC 1/2R-22T-0A-2.5Pa

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7 Calculation of external available Pressure Page 1 Size: 1 Air flow volume [m³/h] 4 6 8 1 12 14 16 18 2 24 28 32 36 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc. to white

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas! Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and

More information

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

HERU 90 LP EC HERU 90 LP EC

HERU 90 LP EC HERU 90 LP EC HERU 90 LP EC HERU 90 LP EC Energy recovery unit with low profile and side connections. Designed for supply and exhaust air ventilation with energy recovery (FTX). Suitable for installation in homes, offices

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Technical Data. 400 Series 403D-15G. ElectropaK

Technical Data. 400 Series 403D-15G. ElectropaK Technical Data 400 Series 403D-15G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement.................................... Vertical

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data 1506A-E88TAG5 293 kwm standby @ 1500 rpm 333 kwm standby @ 1800 rpm 1500 Series Basic technical data Number of cylinders............................................................6 Cylinder arrangement....................................................

More information

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0) 105 kwm (Gross) @ 1500 rpm ElectropaK 1100 Series Basic technical data Number of cylinders.....................................................4 Cylinder arrangement...................................

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

MODULAR AIR HANDLING UNITS GAH SERIES

MODULAR AIR HANDLING UNITS GAH SERIES MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various

More information

Ductable water unit FWD UNT-PRC002-E4

Ductable water unit FWD UNT-PRC002-E4 Ductable water unit FWD 08-1 - 0-0 - 4 UNT-PRC00-E4 Table of Contents General data... Performance data... 4 Cooling capacities... 4 Heating capacities... Water pressure losses... 6 Available static pressure...

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW

vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW B Vortice main company s philosophy is the concept that air is our life. Our

More information

WCTA SERIES Air Handling Units. ( ,000 m 3 /h )

WCTA SERIES Air Handling Units. ( ,000 m 3 /h ) SERIES Air Handling Units ( 1800-115,000 m 3 /h ) 1 1 INDEX pag. 1 INTRODUCTION 4 1.1 Standard Units 4 1.2 Special Units 4 1.3 Size Choice / 1.4 Air Volumes 4-7 2 DIMENSIONAL DATA 7 2.1 Empty Sections

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

Industrial air coolers for cooling & freezing applications Cu/Al

Industrial air coolers for cooling & freezing applications Cu/Al Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK Technical Data @Perkins 400 Series 403D-11G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement....................................

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data 4006-23TAG2A 527-746 kwm (Gross) @ 1500/10 rpm 4006-23TAG3A 566-839 kwm (Gross) @ 1500/10 rpm ElectropaK 4000 Series Basic technical data Number of cylinders....................................................6

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

Technical Data. 400 Series 403D-11G. ElectropaK

Technical Data. 400 Series 403D-11G. ElectropaK Technical Data 400 Series 403D-11G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement.................................... Vertical

More information

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

Heat Exchangers. Evaporator Catalogue

Heat Exchangers. Evaporator Catalogue Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains Compliant with ERP 015 Regulation (EU) No. 7/011 Cert. n 0545 Heating Door Curtains The range of SBIN door curtains offers imum flexibility in the protection of doors and open access compartments. By connecting

More information

3. Dimensions and weights Placement and installation Pressure lost Material... 14

3. Dimensions and weights Placement and installation Pressure lost Material... 14 These technical conditions define the scope of produced dimensions and versions of "ALUMINIUM REGULATION DAMPER RKALM ("damper"). These technical conditions apply to the manufacture, design, ordering,

More information

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series ACOUSTIC CABINET FANS FOR SULY AIR ALICATIONS CAIB/T RO-REG Series Introduction of fresh air to commercial offices and industrial kitchens. Acoustic cabinet fan in galvanised sheet steel with reinforced

More information

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK 1105 kwm Standby @ 1500 rpm Diesel engine - ElectropaK 4000 Series Basic technical data Number of cylinders............................................................8 Cylinder arrangement................................................

More information

IDENTIFICATION ACCESSORIES DESCRIPTION

IDENTIFICATION ACCESSORIES DESCRIPTION Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1 IDENTIFICATION

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias SUBMITTAL Project Palm Beach Gardens Fire Station Date February 5, 2018 Fausto Frias Prepared For TLC Attention- Steve Job Name Palm Beach Gardens Fire Station Mark for AHU-1 Date February 5, 2018 Unit

More information

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)... 527-746 kwm (Gross) @ 1500/1800 rpm 566-839 kwm (Gross) @ 1500/1800 rpm ElectropaK Basic technical data Number of cylinders............................................................6 Cylinder arrangement.......................................

More information

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance 1104D-44TG2 1104D-44TG3 56.6-69.0 kwm (Gross) @ 1500/1800 rpm ElectropaK 1100 Series Basic technical data Number of cylinders.....................................................4 Cylinder arrangement...................................

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation 1106A-70TAG4 196.3 kwm (Gross) @ 1500 rpm ElectropaK Basic technical data Number of cylinders.......................................................6 Cylinder arrangement................................................in-line

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

AIR HANDLING COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

AIR HANDLING COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING HANDING COMMERCIA UIDINGS A guide to our Air Handling Units, including our unique product range, consultancy service and accessories. INNOATIE ENTIATION & HEATING In Partnership with www.pricetwa.co.uk

More information

Pressure control damper ERPA

Pressure control damper ERPA Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents Residential HEE motor Silent operation Heating capacity: 200 W to 4 kw Cooling capacity: 100 W to 3 kw Operation is CIAT's residential. This vertical cased unit, designed for heating and cooling, is available

More information

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor Maestro High Pressure Fan Coil Unit with Asynchronous Motor The Maestro high pressure fan coils are produced in 5 sizes. Designed and built for concealed installations, they have small dimensions, are

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

And ASEAN EAW WATER) Head. Office : Ruko

And ASEAN EAW WATER) Head. Office : Ruko The Winner of INDONESIA ENERGY AWARD 2013 And ASEAN ENERGY AWARD 2004 2012 AIR HANDLING UNIT (AHU CHILLED WATER) 1.600 M³/ /hr. 52.000 M³/hr EAW CHILLED WATER PT. METROPOLITAN BAYU INDUSTRI A member of

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data Technical Data 4000 Series Diesel Engine - ElectropaK Basic technical data Number of cylinders...................................................12 Cylinder arrangement..........................................

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

HR Combi-line. Heat recovery unit with heat pump on extended AHU base frame. Aluminum anodized Pentapost coldbridge free frame construction

HR Combi-line. Heat recovery unit with heat pump on extended AHU base frame. Aluminum anodized Pentapost coldbridge free frame construction HR ombi-line Heat recovery unit with heat pump on extended AHU base frame High Efficiency > 90% Aluminum anodized Pentapost coldbridge free frame construction Panels 45mm double-walled, color RAL 9002

More information

Everest XV. ErP. High Efficiency HRV Fan Unit READY

Everest XV. ErP. High Efficiency HRV Fan Unit READY High Efficiency HRV Fan Unit ErP READY Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart Control system

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information